Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance GROUND FLOOR ASHFAQ HUSSAIN AL ABASS A S RELIEF TRUST BUILDING KARAN NAGAR SRINAGAR 91495 SRINAGAR JAMMU AND KASHMIR 190010 | SRINAGAR | JAMMU AND KASHMIR | 190010 | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹1.0 Cr
EMD Value
₹2.1 L
Closing Date
24 Dec 2020, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SUPERINTENDING ENGINEER O AND M CIRCLE BIJBEHARA
SUPERINTENDING ENGINEER O AND M CIRCLE BIJBEHARA
Supply, Installation, Testing AND Commissioning of LT Protection of Distribution Transformers of Capacities installed on specified 11 KV Feeders, Bugam. Tarigam, Hablish, Nassu, D.H.Pora and Yaripora-B of Electric Division Kulgam.
2020_PDD_111181_1
SEB-OM-TS-22 OF 2020-21
Open Tender
Electrical Works
Turn-key
60 days
ED-KULGAM
VALID REGISTRATION CERTIFICATE, GSTIN, PAN, LATEST GST AND IT RETURN, LABOUR REGN.
7 documents required · 7 mandatory
₹5,000
SUPERINTENDING ENGINEER O AND M CIRCLE BIJBEHARA
₹2.1 L
SE O AND CIRCLE OFFICE BIJBEHARA
26 Dec 2020
10 Dec 2020
26 Dec 2020
10 Dec 2020
24 Dec 2020
10 Dec 2020
10 Dec 2020 - 24 Dec 2020
14 Dec 2020
120 days
Amount
A. For 630 KVA Distribution Transformer Supply,fixing,testing and commissioning of 630 Amp 3 Pole Thermal Magnetic MCCB's having adjustable thermal (0.8 In-1.0 In) . with fixed magnetic setting of 10*In, breaking capacity not less than 65kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage(Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations. ABB/EATON/HAVELLS/L&T/SCHNEIDER/SEIMENS/LEGRAND
Supply, Fixing , testing & Commissioning M S Enclosure (1440X1140X450) with Busbar (Aluminium) not less than 1200 mm sq. for 2 No. 630A MCCBs, Cable Holding arrangement of suitable size for holding cable, with rubber glands . The thickness of enclosure on load bearing side (Backside/Frontside) should not be less than 3 mm and not less than 2 mm for all other sides . Surface preparation by chemical pre-treatment using electrostatic powder painting process minimum coating thickness 80 microns. The Enclosure shall be dust, moisture & vermin proof for tropical use and shall provide a degree of protection not less than IP-55 in accordance with IS:2147 complete as per the drawings annexed. This includes earthing of the enclosure and earthing of neutral (earthing will be done using GI strip of size as per standard). The neutral shall be terminated through Neutral busbar of rated operational current (Ie) 1400 Amps having Impulse Withstand voltage (Uimp) of 3kV . (Makes: 1. Tricolite Energy Solutions. 2. Balaji Switchgears. 3. Metfab Products. 4. Milestones Switchgears. 5. M B Automation 6. ALBA Power or equivalent makes/designs)
Providing and fixing of Bi-metalic Clamps suitabe for vertical entry of 400 sqmm cable and 630 kVA DT LT Bush rods.
Supply & Fixing of M.S Iron Cross Arm (75*40*5mm).with one coat of red oxide and two coats of aluminium paint/ Support Angle frame & legs (50x50x6 mm) for Distribution feeder pillar, leg height 1 mt. with 0.3 mt in soil approx. ( Size of MS Iron as per the site requirement for Pole mounted/ Plinth Mounted Structure)
Providing and fixing of Galvanized Nuts and Bolts of Sorts
Providing and fixing of Galvanized Pole Collar /Clamps
Supply,laying,Testing and Commissioning of 400 mm sq 1-core 1.1 KV grade , stranded Aluminium Conductor, XLPE insulated PVC Outer Sheathed, Unarmoured cable (Havells/Gloster/Polycab/Paramount/Grandlay)) as per IS-7098 amended up to date
Providing and fixing of Pad Clamps of suitable size for 400 sq mm Cable
Providing and fixing of 400 mm sq Aluminium Thimbles.
Cement Grounting 1:2:4 of Standalone arrangement of LTDB
B. For 400 KVA Distribution Transformer Supply,fixing,testing and commissioning of 400 Amp 3 Pole Thermal Magnetic MCCB's having adjustable thermal (0.8 In-1.0 In) . with fixed magnetic setting of 10*In, breaking capacity not less than 65kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage(Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations. ABB/EATON/HAVELLS/L&T/SCHNEIDER/SEIMENS/LEGRAND
Supply, Fixing , testing & Commissioning M S Enclosure (1440X1140X450) with Busbar (Aluminium) not less than 800 mm sq. for 2 No. 400A MCCBs, Cable Holding arrangement of suitable size for holding cable, with rubber glands The thickness of enclosure on load bearing side (Backside/Frontside) should not be less than 3 mm and not less than 2 mm for all other sides . Surface preparation by chemical pre-treatment using electrostatic powder painting process minimum coating thickness 80 microns. The Enclosure shall be dust, moisture & vermin proof for tropical use and shall provide a degree of protection not less than IP-55 in accordance with IS:2147 complete as per the drawings annexed. This includes earthing of the enclosure and earthing of neutral (earthing will be done using GI strip of size as per standard). The neutral shall be terminated through Neutral busbar of rated operational current (Ie) 1400 Amps having Impulse Withstand voltage (Uimp) of 3kV . (Makes: 1. Tricolite Energy Solutions. 2. Balaji Switchgears. 3. Metfab Products. 4. Milestones Switchgears. 5. M B Automation 6. ALBA Power or equivalent makes/designs)
Providing and fixing of Bi-metalic Clamps suitabe for vertical entry of 300 sqmm cable and 400 kVA DT LT Bush rods.
Supply & Fixing of M.S Iron Cross Arm (75*40*5mm).with one coat of red oxide and two coats of aluminium paint/ Support Angle frame & legs (50x50x6 mm) for Distribution feeder pillar, leg height 1 mt. with 0.3 mt in soil approx. ( Size of MS Iron as per the site requirement for Pole mounted/ Plinth Mounted Structure)
Providing and fixing of Galvanized Nuts and Bolts of Sorts
Providing and fixing of Galvanized Pole Collar /Clamps
Supply,laying,Testing and Commissioning of 300 mm sq 1-core 1.1 KV grade , stranded Aluminium Conductor, XLPE insulated PVC Outer Sheathed, Unarmoured cable (Havells/Gloster/Polycab/Paramount/Grandlay) as per IS-7098 amended up to date
Providing and fixing of Pad Clamps of suitable size for 300 sq mm Cable
Providing and fixing of 300 mm sq Aluminium Thimbles.
Cement Grounting 1:2:4 of Standalone arrangement of LTDB
C. For 250 KVA Distribution Transformer Supply,fixing,testing and commissioning of 400 Amp 3 Pole Thermal Magnetic MCCB's having adjustable thermal (0.8 In-1.0 In) . with fixed magnetic setting of 10*In, breaking capacity not less than 65kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage(Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations. ABB/EATON/HAVELLS/L&T/SCHNEIDER/SEIMENS/LEGRAND
Supply, Fixing , testing & Commissioning M S Enclosure (1190X710X355) with Busbar (Aluminium) not less than 500 mm sq. for Single 400A MCCBs, Cable Holding arrangement of suitable size for holding cable, with rubber glands. The thickness of enclosure on load bearing side (Backside/Frontside) should not be less than 3 mm and not less than 2 mm for all other sides . Surface preparation by chemical pre-treatment using electrostatic powder painting process minimum coating thickness 80 microns. The Enclosure shall be dust, moisture & vermin proof for tropical use and shall provide a degree of protection not less than IP-55 in accordance with IS:2147 complete as per the drawings annexed. This includes earthing of the enclosure and earthing of neutral (earthing will be done using GI strip of size as per standard). The neutral shall be terminated through Neutral busbar of rated operational current (Ie) 1400 Amps having Impulse Withstand voltage (Uimp) of 3kV. (Makes: 1. Tricolite Energy Solutions. 2. Balaji Switchgears. 3. Metfab Products. 4. Milestones Switchgears. 5. M B Automation 6. ALBA Power or equivalent makes/designs)
Providing and fixing of Bi-metalic Clamps suitabe for vertical entry of 300 sqmm cable and 250 kVA DT LT Bush rods.
Supply & Fixing of M.S Iron Cross Arm (75*40*5mm).with one coat of red oxide and two coats of aluminium paint/ Support Angle frame & legs (50x50x6 mm) for Distribution feeder pillar, leg height 1 mt. with 0.3 mt in soil approx. ( Size of MS Iron as per the site requirement for Pole mounted/ Plinth Mounted Structure)
Providing and fixing of Galvanized Nuts and Bolts of Sorts
Providing and fixing of Galvanized Pole Collar /Clamps
Supply,laying,Testing and Commissioning of 300 mm sq 1-core 1.1 KV grade , stranded Aluminium Conductor, XLPE insulated PVC Outer Sheathed, Unarmoured cable (Havells/Gloster/Polycab/Paramount/Grandlay) as per IS-7098 amended up to date
Providing and fixing of Pad Clamps of suitable size for 300 sq mm Cable
Providing and fixing of 300 mm sq Aluminium Thimbles.
Cement Grounting 1:2:4 of Standalone arrangement of LTDB
D. For 100 KVA Distribution Transformer Supply,fixing,testing and commissioning of 160 Amp 3 Pole Thermal Magnetic MCCB's having adjustable thermal (0.8 In-1.0 In) . with fixed magnetic setting of 10*In, breaking capacity not less than 50kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage(Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations. ABB/EATON/HAVELLS/L&T/SCHNEIDER/SEIMENS/LEGRAND
Supply, Fixing , testing & Commissioning M S Enclosure (860X550X300) with Busbar (Aluminium) not less than 250 mm sq. for Single 160A MCCBs, Cable Holding arrangement of suitable size for holding cable, with rubber glands. The thickness of enclosure on load bearing side (Backside/Frontside) should not be less than 3 mm and not less than 2 mm for all other sides . Surface preparation by chemical pre-treatment using electrostatic powder painting process minimum coating thickness 80 microns. The Enclosure shall be dust, moisture & vermin proof for tropical use and shall provide a degree of protection not less than IP-55 in accordance with IS:2147 complete as per the drawings annexed. This includes earthing of the enclosure and earthing of neutral (earthing will be done using GI strip of size as per standard). The neutral shall be terminated through Neutral busbar of rated operational current (Ie) 1400 Amps having Impulse Withstand voltage (Uimp) of 3kV . (Makes: 1. Tricolite Energy Solutions. 2. Balaji Switchgears. 3. Metfab Products. 4. Milestones Switchgears. 5. M B Automation 6. ALBA Power or equivalent makes/designs)
Providing and fixing of Bi-metalic Clamps for Transformer suitabe for vertical entry of 185 sqmm cable and 100 kVA DT LT Bush rods.
Supply & Fixing of M.S Iron Cross Arm (75*40*5mm).with one coat of red oxide and two coats of aluminium paint/ Support Angle frame & legs (50x50x6 mm) for Distribution feeder pillar, leg height 1 mt. with 0.3 mt in soil approx. ( Size of MS Iron as per the site requirement for Pole mounted/ Plinth Mounted Structure)
Providing and fixing of Galvanized Nuts and Bolts of Sorts
Providing and fixing of Galvanized Pole Collar /Clamps
Supply,laying,Testing and Commissioning of 185 mm sq 1-core 1.1 KV grade , stranded Aluminium Conductor, XLPE insulated PVC Outer Sheathed, Unarmoured cable (Havells/Gloster/Polycab/Paramount/Grandlay) as per IS-7098 amended up to date
Providing and fixing of Pad Clamps of suitable size for 185 sq mm Cable
Providing and fixing of 185 mm sq Aluminium Thimbles.
Cement Grounting 1:2:4 of Standalone arrangement of LTDB
E. For 63 KVA Distribution Transformer Supply, Supply,fixing,testing and commissioning of 100 Amp 3 Pole Thermal Magnetic MCCB's having adjustable thermal (0.8 In-1.0 In) . with fixed magnetic setting of 10*In, breaking capacity not less than 36 kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage(Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations. ABB/EATON/HAVELLS/L&T/SCHNEIDER/SEIMENS/LEGRAND
Supply, Fixing , testing & Commissioning M S Enclosure (860X550X300) with Busbar (Aluminium) not less than 150 mm sq. for Single 100A MCCBs, Cable Holding arrangement of suitable size for holding cable, with rubber glands. The thickness of enclosure on load bearing side (Backside/Frontside) should not be less than 3 mm and not less than 2 mm for all other sides . Surface preparation by chemical pre-treatment using electrostatic powder painting process minimum coating thickness 80 microns. The Enclosure shall be dust, moisture & vermin proof for tropical use and shall provide a degree of protection not less than IP-55 in accordance with IS:2147 complete as per the drawings annexed. This includes earthing of the enclosure and earthing of neutral (earthing will be done using GI strip of size as per standard). The neutral shall be terminated through Neutral busbar of rated operational current (Ie) 1400 Amps having Impulse Withstand voltage (Uimp) of 3kV . (Makes: 1. Tricolite Energy Solutions. 2. Balaji Switchgears. 3. Metfab Products. 4. Milestones Switchgears. 5. M B Automation 6. ALBA Power or equivalent makes/designs)
Providing and fixing of Bi-metalic Clamps for Transformer suitabe for vertical entry of 95 sqmm cable and 63 kVA DT LT Bush rods.
Supply & Fixing of M.S Iron Cross Arm (75*40*5mm).with one coat of red oxide and two coats of aluminium paint/ Support Angle frame & legs (50x50x6 mm) for Distribution feeder pillar, leg height 1 mt. with 0.3 mt in soil approx. ( Size of MS Iron as per the site requirement for Pole mounted/ Plinth Mounted Structure)
Providing and fixing of Galvanized Nuts and Bolts of Sorts
Providing and fixing of Galvanized Pole Collar /Clamps
Supply,laying,Testing and Commissioning of 95 mm sq 1-core 1.1 KV grade , stranded Aluminium Conductor, XLPE insulated PVC Outer Sheathed, Unarmoured cable (Havells/Gloster/Polycab/Paramount/Grandlay) as per IS-7098 amended up to date
Providing and fixing of 95 mm sq Aluminium Thimbles.
Cement Grounting 1:2:4 of Standalone arrangement of LTDB
F. For 25 KVA Distribution Transformer Supply,fixing,testing and commissioning of 40 Amp 3 Pole Thermal Magnetic MCCB's having adjustable thermal (0.8 In-1.0 In) . with fixed magnetic setting of 10*In, breaking capacity not less than 36kA (Ics=Icu=100%), with spreader links, phase barriers, & direct mounting rotary operating mechanism(ROM). The ROM shall be lockable in OFF position. The MCCB should be CE marked and shall conform to IEC:60947-2-2003 Standards. The MCCB shall have a maximum operational voltage(Ue) 690V, insulation voltage (Ui) 1000V, and impulse withstand voltage (Uimp) 8kV. MCCBs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: ON, OFF and TRIPPED, Total Opening Time <10msec, Mechanical Life 25000 operations & Electrical Life @415V AC 10000 operations. ABB/EATON/HAVELLS/L&T/SCHNEIDER/SEIMENS/LEGRAND
Supply, Fixing , testing & Commissioning M S Enclosure (860X550X300) with Busbar (Aluminium) not less than 75 mm sq. for Single 40A MCCBs, Cable Holding arrangement of suitable size for holding cable, with rubber glands. The thickness of enclosure on load bearing side (Backside/Frontside) should not be less than 3 mm and not less than 2 mm for all other sides . Surface preparation by chemical pre-treatment using electrostatic powder painting process minimum coating thickness 80 microns. The Enclosure shall be dust, moisture & vermin proof for tropical use and shall provide a degree of protection not less than IP-55 in accordance with IS:2147 complete as per the drawings annexed. This includes earthing of the enclosure and earthing of neutral (earthing will be done using GI strip of size as per standard). The neutral shall be terminated through Neutral busbar of rated operational current (Ie) 1400 Amps having Impulse Withstand voltage (Uimp) of 3kV. (Makes: 1. Tricolite Energy Solutions. 2. Balaji Switchgears. 3. Metfab Products. 4. Milestones Switchgears. 5. M B Automation 6. ALBA Power or equivalent makes/designs)
Providing and fixing of Bi-metalic Clamps for Transformer suitabe for vertical entry of 35sqmm cable and 16kVA/25kVA DT LT Bush rods.
Supply & Fixing of M.S Iron Cross Arm (75*40*5mm).with one coat of red oxide and two coats of aluminium paint/ Support Angle frame & legs (50x50x6 mm) for Distribution feeder pillar, leg height 1 mt. with 0.3 mt in soil approx. ( Size of MS Iron as per the site requirement for Pole mounted/ Plinth Mounted Structure)
Providing and fixing of Galvanized Nuts and Bolts of Sorts
Providing and fixing of Galvanized Pole Collar /Clamps
Supply,laying,Testing and Commissioning of 35 mm sq 1-core 1.1 KV grade , stranded Aluminium Conductor, XLPE insulated PVC Outer Sheathed, Unarmoured cable (Havells/Gloster/Polycab/Paramount/Grandlay) as per IS-7098 amended up to date
Providing and fixing of 35 mm sq Aluminium Thimbles.
Cement Grounting 1:2:4 of Standalone arrangement of LTDB
M/S BHAT POWER PVT. LTD.
M/S MARIB CONSTRUCTIONS
LUBNA ENTERPRISE
M/S Soban Electrical
MS BASIT ELECTRICAL
stage.html
html • 0.03 MB
finance_212672.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .