Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L1 | Accepted-AOC lowest Bidder | |
| 2 | L2₹24.8 L+₹98,973 (4.16%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹38.1 L+₹14.3 L (59.9%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹29.9 L+₹6.1 L (25.6%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
30 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE P Kanasar
GE P Kanasar, Military Station Kanasar, Kanasar Bikaner
Repair/replacement of old conventional flame proof light fitting into LED flame proof light fitting in certain bldgs at Kanasar Military Station
2021_MES_485619_1
CA NO. GE (P) KNS/Token No. 21 /2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
GE P Kanasar
Contractor shall be enlisted with MES in Class D and above and category b(i) subject to satisfactory remarks wrt performance in respect of works in hand as reflected in WLR.Contractor not enlisted with MES should meet the enlistment criteria of D
8 documents required · 8 mandatory
₹500
GE (P) Kanasar
₹60,000
Yes
13 Dec 2021
1 Nov 2021
2 Dec 2021
1 Nov 2021
30 Nov 2021
15 Nov 2021
1 Nov 2021 - 8 Nov 2021
60 days
Amount
M & L for taking down of Flame proof 4 feet tubelight light fitting of capacity 36W/ 40W installed on wall / roof etc and opening the fitting cover / bottom by removing of nut / bolts / screws etc , making necessary modification / bypass arrangement for fitting of LED 20 Watt T8 retrofit lamp including replacement of old flurocent lamp holder / bipin holder G13 push type by new G13 push holder on both side and Supply, fixing in replacement and testing new 4 feet LED 20Watt lamp, T8 retrofit, two pin on both side, including driver length 4 feet operating voltage range 220-240 V, AC, frequency 50 Hz, CRI> 80%, inbuilt surge protection and SMPS based driver ,CCT 6500K, frosted glass having as per IS-16102-1 (2012) with latest amendments and input voltage, P.F should be more than 0.9 with total harmonic distortion (THD) less than 10%, cool white colour . LED lamp should be suitable for ambient temperature from -10 ºC to 45 º and humidity level 10% to 90% RH. The efficiency of LED luminaries system be more than 120 lumens per watt and must be certified by the LM-79 test report. After modification /replacement, re fixing the same Flame proof tube light fitting on original place and position etc complete all as specified & as directed.
M & L for taking down of Flame proof Bulk head light fitting of capacity 24W installed on wall / roof etc and opening the fitting cover / bottom by removing of nut / bolts / screws etc, making necessary modification for fitting of LED bulb of capacity 12W including replacement of B22 type bulb holder by new one batten bulb holder and Supply, fixing in replacement and testing old lamp by new LED lamp of capacity 12W, base B22, including driver operating voltage range 140 V-270 V, AC, frequency 50 Hz, CRI> 80%, , inbuilt surge protection and SMPS based driver , CCT 6500K, frosted glass as per IS-16102-1 (2012) with latest amendments and input voltage. P.F should be more than 0.9 with total harmonic distortions (THD) less than 10%, cool white colour . LED lamp should be suitable for ambient temperature from -10 ºC to 45 º C and humidity level 10% to 90% RH. The efficiency of LED luminaries system be more than 100 lumens per watt and must be certified by the LM-79 test report. After modification / replacement , re-fixing the same Flame proof Bulk head fitting on original place and position etc complete all as specified & as directed.
M & L for taking down of Flame proof 2 feet / 2.5 feet tubelight light fitting of capacity 36W installed on wall / roof and opening the fitting cover / bottom by removing of nut / bolts / screws, making necessary modification for fitting of LED PL-L light of capacity 18 Watt including replacement of old florescent PL light type bulb holder by new 2G11 type holder and Supply, fixing in replacement and testing new LED PL-L lamp of capacity 18W base 2G11 , four pin, length 419 mm, width 44 mm, height 29 mm, operating voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, inbuilt surge protection and SMPS based driver , CCT 6500K , frosted glass as per IS-16102-1 (2012), light colour warm white 6500K, frosted glass as per IS-16102-1 (2012) with latest amendments and input voltage P.F should be more than 0.9 with total harmonic distoration (THD) less than 10%, cool white colour and LED lamps hould be suitable for ambient temperature from -10ºC to 45ºC and humidity level 10% to 90% RH. The efficiency of LED luminaries system be more than 130 lumens per watt and must be certified by the LM-79 test report. After modification/ replacement, re-fixing the same Flame proof tube light fitting on original place and position etc complete all as specified & as directed.
M & L for taking down of old Flame proof MH / HPMV High bay / Bulk head lights of capacity 400 Watt installed on wall / roof etc and Supply, fixing in replacement and testing Flame Proof LED High Bay light fitting sunflower type of 120 Watt well glass fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group :, IIA, IIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed, dust and water proof with IP 66 protection certified by CIMFR Dhanbad and having terminals for looping of cables, M20 type cable entry ( for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / hang from ceiling with the help hook and nut / bolt / metal structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case, LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened, type "A". The luminaries shall be monolithic construction as per IS-16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than 10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC. Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10 ºC to 45 ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 120 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed.
M & L for taking down of old Flame proof MH / HPMV High bay / Bulk head lights of capacity 250 Watt installed on wall / roof and and Supply, fixing in replacement and testing Flame Proof LED High Bay light fitting sunflower type of 100 Watt ,well glass fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group :, IIA, IIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed dust and water proof with IP 66 protection certified by CIMFR Dhanbad and having terminals for looping of cables M20 type cable entry (for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / hang from ceiling with the help hook and nut / bolt / metal structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened type "A" . The luminaries shall be monolithic construction as per IS-16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80% P.F should be more than 0.95 with total harmonic distortions (THD) less than 10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC, Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10 º C to 45ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 120 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed.
M & L for taking down of old Flame proof MH / HPMV High bay / Bulk head lights of capacity 200 Watt installed on wall / roof etc and Supply, fixing in replacement and testing Flame Proof LED High Bay light fitting sunflower type of 90 Watt well glass fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group :, IIA, IIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed dust and water proof with IP 66 protection certified by CIMFR Dhanbad and having terminals for looping of cables M20 type cable entry (for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / hang from ceiling with the help hook and nut / bolt / metal structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened type "A" . The luminaries shall be monolithic construction as per IS-16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than 10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC, Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10 ºC to 45 ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 120 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed. .
M & L for taking down of old Flame proof MH / HPMV High bay / Bulk head lights of capacity 150 Watt installed on wall / roof etc and Supply, fixing in replacement and testing Flame Proof LED High Bay light fitting sunflower type of 70 Watt-75 Watt well glass fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group :IIA, IIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed dust and water proof with IP 66 protection certified by CIMFR Dhanbad and having terminals for looping of cables M20 type cable entry (for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / hang from ceiling with the help hook and nut / bolt / metal structure arrangement complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened type "A" . The luminaries shall be monolithic construction as per IS-16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than 10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC, Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10ºC to 45ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 120 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed.
M & L for taking down of old Flame proof MH / HPMV High bay / Bulk head lights of capacity 150 Watt installed on wall / roof etc and Supply, fixing in replacement and testing Flame Proof LED Bulk head light fitting of 70 Watt-75 Watt fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group : IIA, IIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed dust and water proof with IP 66 protection certified by CIMFR Dhanbad and having terminals for looping of cables M20 type cable entry (for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / mount on horizontal wall with the help of nut / bolt / metal column structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened type "A", Earthing 01 Nos inside 1 outside The luminaries shall be monolithic construction as per IS-16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than 10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver, efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC, Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10ºC to 45ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 120 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed.
M & L for taking down of old Flame proof MH / HPMV High bay / Bulk head lights of capacity 75 Watt installed on wall / roof etc and Supply, fixing in replacement and testing Flame Proof LED Bulk head light fitting of 34 Watt-45 Watt fitting including LED lamps, as per IS / IEC 60079-1: 2014 and 60529:2001, gas group : IIA, IIB, Zone 1 & 2, Temp class T5 / T6, totally enclosed dust and water proof with IP 66 protection certified by CIMFR Dhanbad and having terminals for looping of cables M20 type cable entry (for two entries for cable 3/4" x 2 nos) with cable glands and PVC cover to be fixed / mount on horizontal wall with the help of nut / bolt / metal column structure arrangement etc complete with body robust, corrosion resistant, superior finish and without any cracks or through holes, made in a single piece by high pressure die case LM6 aluminium alloy. Heat & Impact resistant clear glass, toughened type "A" Earthing 01 Nos inside 1 outside, The luminaries shall be monolithic construction as per IS-16103-2 (2012) with latest amendments and input voltage range 140-270 V, AC, frequency 50 Hz, CRI> 80%, P.F should be more than 0.95 with total harmonic distortions (THD) less than 10%, cool white colour temperature 6500 K .Independent potted IP 67 SMPS based Driver efficiency more than 85 % along with surge protector of rating 4 KVA with built in SPD. Driver should be constant current constant voltage driver. Driver should have high voltage withstanding capacity upto 440 V, AC, Driver should also have double phase protection, no load, open circuit and short circuit protection. LED light fitting should be suitable for ambient temperature from-10ºC to 45ºC and humidity level 10% to 90% RH. Covers should be polycarbonate/toughened glass to ensure IP 66 degree protection. Cover should not degrade due to heating and ageing. The efficiency of LED luminaries system be more than 120 lumens per watt and must be certified by the LM-79 test report etc complete all as specified & as directed.
Supply and laying, testing and commissioning in replacement LT copper cable 1.1 KV Grade 2.5 Sqmm 3 core steel wire armoured PVC insulated copper cable conforming to IS-7098 , CM/L 566489 laid in duct / tray / wall / ceiling with the help of steel clamps including cable glands with rubber cover etc complete all as specified & as directed.
M/S JALANDRA CONSTRUCTIONS
LAKSHMI ASSOCIATES
BIDAWAT ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .