Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹4.8 L
EMD Value
₹12,000
Closing Date
29 Aug 2024, 11:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Directorate of Municipal Administration
Vinayaka K P
Re-Drilling of existing tubewell and installation of motar pump with pipeline work at ward no 06 of Tarikere Town
DMA/2024-25/WS/WORK_INDENT24002
DMA/2024-25/WS/WORK_INDENT24002
Open
Water supply/sewage lines
Two Tender Document System(Two Cover)
DMA Town Municipal Council Tarikere
5 documents required · 5 mandatory
The bidder should have executed at least one drain work of 2.40 lakhs in any Government/ Department during last five preceding years. The bidder should produce work done certificate issued from the competent authority.
GST Registration Certificate
EPF registration certificate. The intending contractor should compulsorily register with EPF authorities.
A valid copy of PWD registration certificate
Line of Credit 1.44 Lakhs
The bidder should have a minimum average annual turnover of at least Rs.4.80 lakhs during any two years of the last five preceding years (2019-20,2020-21,2021-22,2022-23,2023-24). Balance sheet, profit and loss account certified by the chartered accountant shall be furnished as a proof of the turnover with UDIN Certification.(Financial turnover of previous year shall be given weightage of 10% per year to bring them to the present price level of the financial year in which the tenders are invited)
₹500
₹12,000
9 Aug 2024
9 Aug 2024
1 Sept 2024
17 Aug 2024
Re-Drilling of existing tubewell and installation of motar pump with pipeline work at ward no 06 of Tarikere Town
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars an...
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and ...
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and ...
Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and ...
Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary am...
Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, includi...
Providing wrought mild steel (galvanized) GI collar confirming to IS1239-II, 1991 with latest amendments if any.For 40 mm dia GI collar:
Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments 1x3x4 m2
Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog ...
Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well cap...
Earth work excavation for pipeline trenches in all kinds of soils by mechanical means as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricadin...
Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joint...
Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 ...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
24002.doc
Tender Document • 1.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .