Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹13.9 L+₹1.5 L (12.4%)Rejected-Finance SALGAONKAR HOUSE DRIVERS HILL VASCO DA GAMA GOA 403802 | SOUTH GOA | GOA | 403802 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹14.0 L+₹1.6 L (12.7%)Rejected-Finance | L3 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
8 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SHRI JANAK RAJ EE GARRISON ENGINEER NW
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802.
8287/E8
2020_MES_366052_1
8287/E8
Open Tender
Civil Works
Item Rate
180 days
VASCO
Class E Category a i
8 documents required · 8 mandatory
₹500
Yes
GE NW VASCO
₹29,000
Yes
14 Oct 2020
3 Aug 2020
10 Sept 2020
3 Aug 2020
8 Sept 2020
24 Aug 2020
4 Aug 2020 - 21 Aug 2020
60 days
Amount
ADDITION / ALTERATION AND SPECIAL REPAIRS OF EXISTING EXIT/ENTRANCE IN BLDG P-482 AT NAY (G)
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / disintegrated rock
PCC type D2 1:4:8 (40mm aggregate) in foundations filling and mass concrete
Reinforced cement concrete of mix 1:1½:3, 20mm graded aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete
Reinforced cement concrete of mix 1:1½:3, 20mm graded aggregate as in Columns, pillars, piers, posts and struts
Reinforced cement concrete of mix 1:1½:3, 20mm graded aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span
Reinforced cement concrete of mix 1:1½:3, 20mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L Mild steel bars 10 mm dia and over, cut to length, bent to shape required including crancking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to TMT Bars.
M&L Mild steel bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including crancking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to TMT Bars.
Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Use and waste Formwork to sides of pillars, posts, struts, piers, columns and stanchions
Use and waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc.
Use and waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
Earth filling under floor including spreading, levelling & well ramming including watering as required n exc. 25 cm thick. (Note :- (i) Earth obtained from item No. 1.01 is reused.)
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed
Demolition of Block / brick masonry built in cement mortar.
M&L Pre-cast cement concrete block masonry (Type C1 1:3:6 , 20 mm graded aggregate) with solid blocks, exc. 10 cm in width and setting in CM 1:6, complete all as specified and as directed by Engineer-in-Charge.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
M&L Rendering 15 mm thick cement plaster on concrete solid block walls in CM 1:4 finished to even & smooth w/o using extra cement.
M&L Rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with 3% integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing liquid will be measured and paid separately.
M&L Rendering 15 mm thick cement plaster on ceiling in two coats first coat of 10 mm in CM 1:4 & 2nd coat of 5mm in CM 1:4 mixed with 3% integral water proofing compound finished to even & smooth w/o using extra cement. Note :- Integral water proofing liquid will be measured and paid separately.
M&L Preparing new plastered ceiling surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling.
M&L Preparing new plastered wall surfaces and applying two coat of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall
Preparation of New plastered surface and applying two coats of weather proof high glove antifungal paint on external surface with suitable primer
Providing 10mm thick plaster in CM (1:4) mixed with 3% integral water proofing compound over roof top surface finished to even & smooth w/o using extra cement. Note :- Integral water proofing compound will be measured and paid separately.
M&L for preparation of surface with wire brush and remove loose particle & laitance, wash with clean water, damaged or hollow portion, sharp edges etc. must be cut and removed till the morther slab. Filling the cracks and damaged portion with polymer mortar and allow it to cure for 24 hrs. Brush apply the 1st Priming coat (Dr. Fixit primeseal or equivalent) on prepared concrete/plastered surface by diluting 2 parts of Primeseal with 1 (one) part of water and allow to dry for 04 (four) hours. Apply the first coat of waterproofing coating (Dr. Fixit Newcoat / Waterseal Concentrate of M/s Krishna Conchem Products) without any dilution at the rate of 2 Sqm per liter over the primed surface. On the wet surface of 1st coat overlay a open-woven fibre glass mesh, min 40 GSM of size 2mm x 2mm and allow it to soak completly. Immediately apply the second coat with a roller, to ensure complete coverage of the fibre mesh. Apply the third coat after 6 to 8 hrs once the second coat is dry. Drying time between coats will be 6 to 8 hours all as directed and as per manufacturer’s instructions.
Supply only Water Proofing Compound
Demolition of Cement Concrete including topping in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M & L 75 mm thick Cement concrete type D2, 1:4:8 (using 40 mm graded stone aggregate) in sub base of flooring / hard standing / pavings / plinth protections, etc.
M&L screed bed or bedding layer of mortar 20 mm thick cement plaster 1:4 for laying floor finished to receive floor tiles.
M&L Vitrified Ceramic tiles of light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors/skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match
M&L coloured heavy duty paving, chequered finish, cement concrete endura industrial tiles 12 to 15 mm thick (square/rectangular) textured series area of each tile exceeding 0.07 sqm not exceeding 0.18 sqm as in floors, treads and risers of steps fixed with grey cement and pigment laid over complete all as per manufacturer instructions and of design as directed by Engineer-in-Charge. Make : Johnson endura industrial or equivalent of Kajaria / Regency.
Taking down chowkat or frames n exc 1.5 sqm each (w/o taking of shutters from the frame).
Taking down chowkat or frames exc 1.5 sqm but n. exc 4 sqm each (w/o taking of shutters from the frame and removing to store)
S&F powder coated aluminium door and window shutter and frame any type (sliding or open able) and other similar work etc 60 micron powder coated section, fabricated by using the JINDAL / INDAL / HINDAL CO / CENTURIAN sections including all necessary roller wheels for window, cleats , handle, door stoper locking arrangement and arrangements to received glass/ prelaminated particle board with aluminium beading and stainless steel screw incl cost of rubber gasket beadings etc complete sealing between frame & wall with epoxy sealing compound. (The weight of rubber gasket beading will not be measured with the weight of aluminium shutters, glass and prelaminated particle board will be measured and paid separately) All sections as approved by GE.
S&F butt hinges medium weight stainless steel 100mm size
Extruded aluminium alloy handles, fabricated type, anodised 150 mm grip size .
Aluminium anodised, barrel tower bolts of extruded section and fixed 150mm size
Aluminium alloy, anodised, sliding door bolt 300mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F 4mm thick sheet glass ordinary quality exceeding 0.5 sqm each pane
Solar control film 50 micron reflective type mirror finish/mirror jet black type (gareware sun control or equivalent)
S&F Toughened glass fixed window with toughened glass of 12 mm thick fixed with aluminium frame including all necessary fittings and frame works. Design : Blumcraft's series or equivalent as approved by GE.
M&L Granite 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and framings and heavy bracket framing (Beam, tee, angle, channel or flat sections) confirming to Fe 410-W including cleats, distance pieces etc
M&L preparing new surfaces of iron and steel applying one coat of redoxide zinc chrome primer and two coats of Epoxy anti- corrosive paint over 10 cm width or girth.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws as specified
Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with ANF (Board) edge tiles with Armstrong 24mm exposed grid. The tiles should have Humidity Resistance (RH) of 90%, NRC 0.5, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm, suitable for Green Building application, with Recycled content of 34%.The tile shall be laid on Armstrong Prelude38 with 24 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15.34Kgs/M2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per M2 and need to be installed with Suspension system of Armstrong make.
PROVISION OF GSE STOWAGE FACILITY AT 321 FLIGHT (BLDG P-18) AT INS HANSA
S&F roof trusses (framed), trussed, posts, rafters, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beem, tee, angle, channel or flat sections) including distance pieses, cleats etc including fixing to roof beam, slab and column with fastning and grouting with araldite liquid resin and hardener, etc complete all as directed by Engineer-in-Charge. Note:- (i) Rate including making base plates and fixing fastning bolts with concrete dispersal area and making good for disturbed portion. (ii) Fastning bolts as approved and as directed.
Prelaminated particle board, 12mm thick, interior grade, prelaminated both side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work
S&F 4mm thick sheet glass ordinary quality frosted on one side n.exc exceeding 0.5 sqm each pane .
ADDITION / ALTERATION OF MAIN ENTRANCE GATE AND PROVISION OF SENTRY POST AT NAY (G)
M&L for plain cement concrere type C2 1:3:6 (40mm graded aggregate) as in foundations, filling and concrete
Returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25cm (soft rock)
Removing excavated material (soil) incl loading, unloading and stacking at the destination up to 1.5 Km
TMT steel bars 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups
M&L rendering 15 mm thick in CM 1:6 on concrete solid block wall internal surface finished even and smooth without using extra cement.
M & L for Glazed coloured ceramic tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointedin white or colour cement to match.
Rendering 10mm thick cm 1:4 on fiar faces of stone masonry wall surfaces, finished even and fair to receive glazed tiles.
M&L Dismantling structural steel work including doors, gates but excluding framed truss etc. (Removal of existing gate)
S & F Framed work such as grills, gratings, etc.. with ends of barshouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including fabrication of framed and hung as gates, pintle hinges, stops, hand-made sliding bolts,.
S & F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment. FE 290 Gde E 165.
Writing letters NAY (Goa) in stainless steel of height 30 cm in capital letter and fixing over glazed tile surface
ADDITION / ALTERATION OF MAIN ENTRANCE GATE AND PROVISION OF SENTRY POST AT NAY (G) (INTERNAL ELECTRIFICATION)
M&L for point FRLS/LS wiring with 1.5 Sq mm nominal area PVC insulated and unsheathed cable single core multistranded, copper conductor in and including PVC conduit concealed with all fittings and fixing materials and PVC insulated multistranded copper earth continuity conductor of size 1.5 Sq mm connecting all as specified and directed for following :-
(a) One light point controlled by one switch one way
(b) One Ceiling fan / Exhaust fan point controlled by one switch one way
All as per item No. 4.01 here in before but with cable size 1.5 Sq mm for one 3 pin 5 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 1.5 sqmm all as specified and directed by Engineer-in-Charge.
All as per item No.4.01 here in before but with cable size 2.5 Sqmm for one 3 pin, 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm all as specified and directed by Engineer-in-Charge.
S & F in repairs for modular switch one way 6 amps.
S & F in repairs modular sockets 6A- 2/3 pin combined 2 module,
S & F in repairs modular sockets 6A/16A- 2/3 pin combined 2 module,
S & F ceiling rose surface bakelite 65x50mm two to three terminals
S & F MCB SP 6 to 32 Amps 240 Volts
S & F MCB SPN 32 Amps 415 volts
S & F DBs 4 Way double door sheet steel, phospetised, powder coated with 200 Amps rated bas bar single door, 230 Volt. Make : Indo asian or equivalent.
S & F ceiling fan AC single phase 230 Volt of size 1200 mm and flexible cable 3 core copper conductor 1.50 mm up to ceiling rose Complete all as specified and directed.
S&F decorative LED 20 watt retrofit tubewith PVC extruded batten complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed by Engineer-in-charge.
S&F energy GLS bulkhead luminaires to LED bulkhead IP 65, 230 volt, 50 HZ, 10 W complete all as specified and directed by Engineer-in-charge.
M & L for sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 4 sqmm as earth continuity conductor drawn through PVC conduit concealed as reqds size confiming to IS: 9537(Part-3), including accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area.
ADDITION / ALTERATION OF MAIN ENTRANCE GATE AND PROVISION OF SENTRY POST AT NAY (G) (EXTERNAL ELECTRIFICATION)
M & L for replacement of sub main wiring with 2 run of FRLS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4.0 sqmm alongwith one run of FRLS PVC insulated & unsheathed copper conductor of nominal cross sectional area 4.0 sqmm as earth continuity conductor drawn through PVC conduit as required size confirming to IS: 9537(Part-3), including accessories fixed on wall/ceiling all as directed including making good of disturbed surfaces area.
Supply and fixing LED Garden lights 9 W, Warm White, suitable for outdoor application, with secondary optics with pressure die-cast aluminium housing, and heat sink in aluminium, complete with all accessories ,lumen efficiency > 90-100 lm/w , CRI > 80% ,PF> 0.95, IP 65 and operating voltage of 140-265 volt complete all as specefied and directed by Engineer-in-charge. Make : Bajaj of Cat Part No. BGSBL9W LED WW, /C&S/ LUKAR
Supply and fixing in replacement of LED Post Top lamp made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection complete with all accessories 70 W and should have 5 KV surge protection, PF > 0.95 complete all as specefied and directed by Engineer-in-charge. Make : Bajaj of Cat Part No . BGCL70 LED WH, /C&S/LUKAR
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core
Excavation in trenches n.exc 1.5M wide & n.exc 1.5m in depth for laying & removing of cable any sizes and getting out in hard/dense soil all as specified.
All as per Item No. 5.05 above but in soft disintegreted rock/ laterite rock
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata
Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5M above the starting point
Supply/ Lay dry river sand /m -sand in trenches for cable protection all as directed. Note : Punned thickness only will be measured & Paid
Supply and lay ISI marked un-reinforced precast concrete cable covers, class LV , type- I with peak, size 250mm x 150mm x 40mm, all as specified and directed.
NOTE :- SIMILAR ITEMS OF ALL WORKS HAS BEEN CLUBBED)
Tara Construction
M/S. M M S ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .