Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹7.4 L+₹1.9 L (35.0%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹7.6 L+₹2.1 L (38.1%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹7.9 L+₹2.4 L (44.4%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹8.7 L+₹3.3 L (59.4%)Rejected-Finance 184 TENGPUNA PULWAMA PULWAMA PULWAMA JAMMU KASHMIR 192301 UDYAM JK 15 0009999 | PULWAMA | JAMMU AND KASHMIR | 192301 | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹24,400
Closing Date
18 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
CERTAIN REPAIR TO INTERNAL ELECTRIFICATION INCLUDING REPAIR TO EARTHING SYSTEM AT 8FBSU, AF STATION AWANTIPUR
2020_MES_407345_1
GE (AF) AWA-22/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
₹24,400
Yes
31 Mar 2021
28 Dec 2020
20 Jan 2021
28 Dec 2020
18 Jan 2021
12 Jan 2021
60 days
Amount
Taking down carefully aluminium/copper point wiring (light, bell, fan, socket) complete including batten/casing caping/conduit, block, ceiling rose, holder, fittings and terminal box sheets complete, stacking material at site and making good the disturbed surface of walls/ floors to match with existing surface, complete all as specified and directed.
Point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping, ISI marked with all connected accessories including one single core multistanded PVC insulated FRLS type, 1.5sqmm copper conductor cable unsheathed as earth continuity cable including concealed pressed steel GI terminal boxes with 3mm thick laminated sheet cover for mounting of switches, socket, fan regulators, complete all as specified and directed for the following:-
(a) One light /fan/bell point controlled by one No, one way 5/6 Amps switch.
(b) One 3/5 pin socket outlet, 5/6 Amp controlled by one no, one way switch on same board.
(c) One 3/5 pin socket outlet, 5/6 Amp, independent, controlled by one no. one way switch on independent board.
Description all as per serial item No. 2 here-in-before, but using FRLS type cable of size 2.50sqmm (for phase & neutral) and 2.5sqmm as continuous earth cable for 15/16 Amps socket outlet independent point on independent board, complete all as specified and directed.
Piano type switch one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz, complete all as specified and directed.
Piano type bell push switch, one way, SP, flush type, 5/6 Amps, 230 volts AC, 50 Hz, complete all as specified and directed.
Piano type socket outlet, flush type, 5 pin, 5/6 Amps, 230 volts AC, 50 Hz, multipurpose type, complete all as specified and directed
Piano type switch socket combination, flush type, 6 pin, 5/15 Amps, 230 volts AC, 50 Hz, multipurpose type, complete all as specified and directed.
Electronic type ceiling fan regulator, 230 volts, single phase, flush type, complete all as specified and directed.
Ceiling rose 3 terminals, PVC/polycarbonate/bakelite, isolated body, 230 volts AC, 50 Hz, complete all as specified and directed.
Electric call bell, ding dong type suitable for 230 volts, single phase AC supply, complete all as specified and directed.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4sqmm complete drawn in and including casing caping of suitable size and its accessories along with 1x 4sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed. Note :- 2 +1 run of 4Sqmm cable including casing caping/conduit of suitable size shall be measured as one running metre.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 4sqmm complete drawn in existing conduit with 1x 4sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed. Note :- 2 +1 run of 4Sqmm cable including casing caping/conduit of suitable size shall be measured as one running metre.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6sqmm complete drawn in and including casing caping ISI marked of suitable size and its accessories along with 1x 4sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified. Note :- 2 run of 6Sqmm & 1 run of 4Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 6sqmm complete drawn in existing conduit along with 1x 4sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed. Note :- 2 run of 6Sqmm & 1 run of 4Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Replacement of submain wiring with PVC insulated unsheathed copper conductor cable, multi stranded, single core, FRLS type, 1100 volts grade 2 x 10sqmm complete drawn in and including casing caping ISI marked of suitable size and its accessories along with 1x 6sqmm PVC insulated unsheathed copper conductor cable, multi stranded for continuous earth wire including making good the disturbed surface, complete all as specified and directed. Note :-2 run of 10Sqmm & 1 run of 6Sqmm cable including casing caping of suitable size shall be measured as one running metre.
Replacement of existing DB's double door With new factory made load line DB's double door made out of CRCA mild steel sheet with insulating material like polyester epoxy quoted surface mounting 4 way TPN 415 volts, vertical type, surface mounting with suitable busbar, neutral link and earth link suitable for MCCB TP as incomer and MCB SP/TP as out going complete with and including one No. MCCB 100 Amps, 3 pole, 25 kA fixed type for incoming, complete all as specified and directed.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure DB SPN 2 way, single door, 230 volts AC, surface mounting complete with suitable for MCB SP/SPN, fixed in repair, complete all as specified and directed.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure DB TPN 4 way, double door, 415 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB TP/TPN as incomer and MCB SP as outgoing, complete all as specified and directed.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure DB SPN 4 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and directed.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure DB SPN 8 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and directed.
Replacement of existing Sheet metal enclosure DB with new Sheet metal enclosure DB SPN 12 way, double door, 230 volts AC, surface mounting complete with suitable busbar, neutral link and earth link suitable for MCB DP/SPN as incomer and MCB SP as outgoing, complete all as specified and directed.
MCB SP, 10-32 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, fixed in repair, complete all as specified and directed.
MCB SPN, 32 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type, fixed in repair, complete all as specified and directed.
MCB SPN, 40-63 Amps, 230 volts, 10 kA rupturing capacity, 'C' curve type,fixed in repair, complete all as specified and directed.
MCB TPN, 40-63 Amps, 415 volts, 10 kA rupturing capacity, 'C' curve type, fixed in repair, complete all as specified and directed.
Replacement of existing LED tube light fitting with new LED tube light fitting box type 230 volts AC suitable for & including 18/20 watts LED tube rod with bipin holders prewired, LED driver including making of electrical connection with & including three core flexible copper conductor cable of suitable size, ccomplete all as specified and directed. Make: Havells Model: Regal batten for Fitting and Photon Ultra LED for tube rod or equivalent in Philips/Crompton.
Replacement of existing LED tube light fitting with new LED tube light fitting box type 230 volts AC suitable for & including 8 watts LED tube rod including bipin holders prewired, LED driver including making of electrical connection with & including three core flexible copper conductor cable of suitable size, complete all as specified and directed. Make of fitting: Crompton model: Mirrorlite or equivalent in Havells/Philips and make of LED tube: Compton model: Retro LED or equivalent in Havells/Philips.
Replacement of existing recess mounting LED light fitting with new recess mounting LED light fitting 36W, 230 volts AC suitable for armstrong/grid ceiling, glare free symmetrical illumination type complete with LED driver, lamp suitable for cutout of size 600mmx600mm including making of electrical connection with & including three core flexible copper conductor cable of suitable size complete with all accessories, complete all as specified and directed. Make: Crompton cat part No. LCTLRN-36-FO-CDL or equivalent in Philips /Crompton.
Replacement of existing LED wall light fitting with new LED wall light fittings 9 watt, 230 volts AC, indoor type made up of polycarbonate complete with B-22 type lamp holder, LED Lamp 9 watts, connector block pre-wired including making of electrical connection with & including two core flexible copper conductor cable of suitable size with all accessories , fixed in repair, ccomplete all as specified and directed. Make: Havells Model City-1 or equivalent in Philips /Crompton.
Replacement of existing LED bulk head light fitting with new LED bulk head light fittings 10 watt, 230 volts AC made up of pressure die cast housing, IP65 protection, 5700K including making of electrical connection with & including two core flexible copper conductor cable of suitable size with all accessories, complete all as specified and directed. Make: Crompton cat part No. LBHN-10-CDL or equivalent in Philips/Havells.
Earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25x4mm dia bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering 20mm GI pipe (medium grade) 20mm bore from bottom of earth pit to top of electrode and 20mm GI pipe light grade for earth wire protection complete with earth pit inplain cement concrete (1:2:4), type B0 using 12.5mm graded crushed stone aggregate with 40 mm thick cover of reinforced cement concrete (1:2:4), type B-I , using 20 mm graded crushed stone aggregate, reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing including testing on completion, complete all as specified and and shown in electrical plate No 3 of MES Schedule 2009 Part-I, and directed . Note:- Earthing to be done for replacement of existing earthing. The materials retrieved from earthing shall be credited to contractor.
Note :- An amount of Rs. 18,385.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S Bali Agencies
MS Ghulam Hassan and Sons
ORISON ENTERPRISES
M/S BASHIR AHMAD AND SONS
M/S ZENITH TRADE LINK
FG CONSTRUCTION
M/S ABBAS M. ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .