Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.4 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹43.4 L+₹6.5 L (17.5%)Rejected-AOC | L2 | Rejected-AOC Other than lowest bidder | |
| 3 | L3₹47.9 L+₹11.0 L (29.7%)Rejected-AOC H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L3 | Rejected-AOC Other than lowest bidder | |
| 4 | L4₹48.7 L+₹11.8 L (32.1%)Rejected-AOC 158 ARATH BAZAR KASAULI 173204 HP | KASAULI | SOLAN | HIMACHAL PRADESH | 173204 | L4 | Rejected-AOC Other than lowest bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
8 Dec 2023, 6:00 pmClosed
Sh. Rahul Meena, IDSE, EE, Garrison Engineer, CEA
GARRISON ENGINEER KASAULI, DISTT SOLAN (HP) PIN 173204 PH 01792273107
REPAIRS AND MAINTENANCE TO EXTERNAL WATER SUPPLY MAINS OFF SIZES, CONNECTED DISTRIBUTION LINES, CONTROL VALVES, MOTOR PUMPSETS AND OTHER ALLIED WORKS AT VARIOUS LOCATIONS OF DAGSHAI UNDER GE KASAULI
2023_MES_627307_1
GEK-87/2023-24
Open Tender
Pipes and Pipe related activities
Item Rate
180 days
DAGSHAI
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE KASAULI
₹98,000
Yes
27 Dec 2023
7 Nov 2023
11 Dec 2023
7 Nov 2023
8 Dec 2023
24 Nov 2023
Amount
Schedule 'A' Section - I
Excavation in trenches in hard dense soil n.exc 1.5 mtr wide & n.exc 1.5mtr in depth and n. exc. 10sqm on plan for laying pipe in trenches and getting out complete all as specified and directed.
Returning filling in trenches, spreading, levelling, watering and well ramming in layers n.exc 25cm in hard dense soil complete all as specified and directed.
Removing of surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above starting point complete all as specified and directed.
Taking out unserviceable/defective/damaged/blockage GI pipe 100 mm bore steel water tubing,sorting out serviceable pipe fitting for reuse and cleaning the pipe including fitting and removing away all unserviceable pipe from site, complete all as specified and as directed. (Note: Exacavation and earhwork shall be measured and paid for separately.)
All as per serial item No. 4.00 here-in-before but of size 80mm bore -ditto-.
S&F GI tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, 100 mm bore with and including all fittings such as bends , elbows,tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches/floor/under culvert/road crossing etc including testing complete all as specified and as directed.
All as per serial item No. 6.00 here-in-before but of size 80 mm bore -ditto-.
Taking out old unsv and Supplying, fixing and testing of cast iron Rising Sluice valve PN1.6 as per IS-14846, body, dome, wedge-CI IS:210, rings-bronze IS:318, Spindal-SS IS:6603, Gland Packing greasy jute packing, fasteners-CS, Gasket- Natural rubber, nominal size DN-150 mm, both ends flanged in existing line, after removal of old unserviceable sluice valve without damaging to existing pipe line complete all as specified and directed by Engr-in-charge. Note : Suitable size flanges for existing pipe line, Joints and jointing materials shall be included under this item.
All as per serial item No. 8 here-in-before but of size 100 mm bore -ditto-.
All as per serial item No. 8 here-in-before but of size 80 mm bore -ditto-.
Taking out old unsv water meter and Supplying, fixing and testing of Electromagnetic Flowmeter with rubber lining of size 50mm bore compatible with online water quality monitoring system installed at ETP/STP, flange type end connection, flange standard conforming to ANSI 150, bidirectional measuring range 0.2 to 12m/sec, with graphic display complete all as specified and directed by Engr-in-charge.
All as per serial item No. 9 here-in-before but of size 80 mm bore -ditto-.
All as per serial item No. 9 here-in-before but of size 100 mm bore -ditto-.
All as per serial item No. 9 here-in-before but of size 150 mm bore -ditto-.
M & L for Construction of brick masonary pit of size 60 x 60 x 60cm internal size with MS sheet 3mm thick and angle iron frame of size 40x40x6mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer including locking arrangement, lifting handle and including excavation / earth work, PCC in foundation, brick work, plaster including demolition of existing pit complete all as specified and directed by Engr-in-charge.
All as per ser item No. 13.00 above but of size 90 x 90 x 90 cm complete all as specified and directed by Engr-in-charge.
All as per ser item No. 13.00 above but of size 120 x 120 x 120cm complete all as specified and directed by Engr-in-charge.
Dismantling and taking out old flanged and drilled pipe line complete with all fittings and flanged joints,150mm dia, including necessary excavation ,returning and filling etc complete, removing unserviceable from site and transporting out of site complete all as specified and directed by Engr-in-charge.
Supplying, laying, jointing and testing hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-150 mm, outer dia 168.30 mm, with nominal wall thickness 7.1 mm and weight 28.22 Kg/ Rm, including short pieces as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified and directed by Engr-in-charge. NOTE:- (i) Excavation Earth work, PCC, seamless pipe fittings, MS flanges & flanged joints shall measured and paid for separatly under relevant items. (ii) Work will be carried out at various locations as and when pipeline breaks down and weaker sections of existing rising main as per site requirement and as directed by Engineer-in-charge. (iii) Any other expenses including permision from state authorities are included under this item.
Supplying, laying, jointing and testing bends, suitable length, radius as specified and as per site requirement, made of hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-150 mm, outer dia 168.30 mm, with nominal wall thickness 7.1 mm and weight 28.2 Kg/ Rm, including short pieces with flanged ends duly fabricated as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified and directed by Engr-in-charge. NOTE:- As per item No-17.00.
Supplying, laying, jointing and testing of Tees, suitable length and as per site requirement, made of hot finished seamless carbon steel pipe not less than YST-240, grade B as per ASTM A 106, Sch 40, nominal size NPS-150 mm, outer dia 168.30 mm, with nominal wall thickness 7.1 mm and weight 28.2 Kg/ Rm, including short pieces with flanged ends duly fabricated as required at site, laid in trenches/over RCC pillars/across or under bridges/along hill side (up or down)/culverts/inside valve pits complete all as specified and directed by Engr-in-charge. NOTE:- As per item No- 17.00.
Supply and fixing heavy duty MS flange of nominal size DN-150, duly painted with two coats of black japan paint, for NPS-150 mm nominal size pipes, 36 mm thick, 345 mm outer dia, having 8 nos hole of size 33 mm drilled for M30 size bolts for jointing with existing pipes,duly welded with pipes/tees/bends properly to both the plain ends complete all as specified and directed by Engr-in-charge.
Supply and fixing Flanged joint for 150mm nominal size pipes comprising of one 3.0 mm steel reinforced compressed asbestos fibre gasket and 8 nos nuts, bolts of size M30 and 125 mm length and 2 nos washers 3 mm thick for each bolt to joint pipes/fittings/bends etc complete all as specified and directed by Engr-in-charge.
M & L for Cutting Seamless carbon steel pipe/ GI pipes in position and reducing to required length for insertion of new tees,branches, Mechanical Joints etc, all as directed. Size of pipe 80/100/150mm bore.
M & L for MS Special fitting of IS 1239 and thickness not less than 7mm fittings any type spigot and socket ends or flanged pipe as required at site (such as bend, taper, Tee, flange, socket etc) Socket end/ flanged as ordered of any size from 80mm to 450mm as required at site. (i) The weight of the fittings shall be measured and paid as given in relevant IS or actually provided which ever is less. (ii) All fittings shall bear relevant IS stamping marking. (iii) Excavation and earth work shall be measured and paid separately. (iv) Cost of the joints and jointing materials shall be deemed to be included in the relevant items of DI pipes here-in-before.
Taking down unserviceable sluice valve from existing position and supply and fixing Gear operated D.I. Sluice valve of 150mm dia bore, D.I. resilient (soft) seated gate valve with pocket less body, SS Stem (AISI 410), EPDM coated DI wedge 100% vaccum tight design with toroidal sealing rings & over 250 micron epoxy coating in PN 16 designed to BS:5163/IS:14846 Non-Rising stem type with gear wheel operation with including necessary arc/gas welding with flange as per existing pipe line , tail pics of MS Pipe as per site requirement not less than 350mm length, dia of tail peace as per existing pipe ,stainless steel spindle of suitable length including suitable size nuts, bolts, washer and rubber gasket all as required and directed at site.
All as per item No 24.00 above but of size of Gear operated D.I. Sluice valve 80 mm -- ditto --,
All as per item No 24.00 above but of size of Gear operated D.I. Sluice valve 100 mm -- ditto --,
Supplying, fixing and testing of high pressure, heavy duty cast steel Sluice valve, nominal size DN-150 mm, conforming to API 600, Class 600, suitable to hydrostatic test pressure for body 156 kg/sq cm & for seat 115 kg/sq cm, both ends flanged in existing line, after removal of old unserviceable gate valve without damaging to existing pipe line complete all as specified and directed by Engr-in-charge. Note : Suitable size MS flanges for existing pipe line, Joints and jointing materials shall be included under this item.
Supplying, fixing and testing of high pressure, heavy duty ball type cast steel Non return valve/ check valve, nominal size DN-150 mm, PN 10, conforming to BS 1868, Class 600, suitable to hydrostatic test pressure for body 156 kg/sq cm & for seat 115 kg/sq cm, both ends flanged in existing line, after removal of old unserviceable non return valve without damaging to existing pipe line complete all as specified and directed by Engr-in-charge. Note : Suitable size MS flanges for existing pipe line, Joints and jointing materials shall be included under this item.
M & L for Two coats of synthetic enameled paint (tint of paint as directed) over one coat of red oxide primer on surfaces over 10 cm width or girth including preparation of new surfaces on mild steel pipe including fittings, Gate valve and NRV etc complete pumpsets upto tanks and complete pipe lines inside distribution tank area to delivery gate valve in pit chamber and writing names/letters using white paint complete as directed at different locations of water supply installation at Dagshai complete all as specified and directed by Engineer-in-charge.
All as per item No 29.00 above but at different locations of water supply distribution tanks as specified and directed by Engineer-in-charge.
Dismantling of defective/unsv 150 mm nominal size pipe line and taking out from trenches with necessary excavation work and carrying out the repair work at site or local work shop for welding work to repair defective portion of pipe line and providing leak proof jointing material to leaked/pierced portion and took back after repair to work site complete and relaying of repaired pipe line 150mm bore in trenches and jointing the same in trenches complete with new gasket, nut bolts and other jointing material including testing/commissioning the pipe line on full pressure complete all as specified and directed by Engr-in-charge. NOTE :- (i) MS flanges & flanged joints shall measured and paid for separately under relevant items. (ii) Work will be carried out at various locations as and when pipe line break downs and weaker sections of existing rising main as per site requirement and as directed by Engineer-in-charge.
All as per ser item No. 31.00 above but for 100 mm dia pipe line complete all as specified and directed.
S&F for PCC (1:3:6) type C2 using 40mm graded stone aggregate for anchorage blocks for pipe line/making good the cut portion of roads/paths/hard standings etc including necessary from work where required , to support the pipe line complete all as specified and as directed by Engineer-in-charge.
S&F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates( Fe 410 -W Grade -E 250 quality A)
S&F for Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment ( Fe 410 -W Grade -E 250 quality A)
M & L for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Taking out unserviceable/defective/damaged/blockage GI pipe 15 mm bore steel water tubing,sorting out serviceable pipe fitting for reuse and cleaning the pipe including fitting and removing away all unserviceable pipe from site, complete all as specified and as directed. (Note: Exacavation and earthwork shall be measured and paid for separately.)
All as per serial item No. 37.00 here-in-before but of size 20mm bore -ditto-.
All as per serial item No. 37.00 here-in-before but of size 25 mm bore -ditto-.
All as per serial item No. 37.00 here-in-before but of size 40mm bore -ditto-.
All as per serial item No. 37.00 here-in-before but of size 50mm bore -ditto-.
S&F GI tubing medium grade, ISI Marked conforming to IS 1239 Part-I 2004, 15mm bore with and including all fittings such as bends , elbows,tees, short length, socket, union, check nuts, nipples etc. fixed and laid in trenches/floor/under culvert/road crossing etc including testing complete all as specified and as directed.
All as per serial item No. 38.00 here-in-before but of size 20mm bore -ditto-.
All as per serial item No. 38.00 here-in-before but of size 25mm bore -ditto-.
All as per serial item No. 38.00 here-in-before but of size 40mm bore -ditto-.
All as per serial item No. 38.00 here-in-before but of size 50mm bore -ditto-.
Taking out old unsv and S&F Bronze gate valve for 15mm bore pipe, with iron wheel head, screwed both ends for iron pipe and fixed, ISI marked conforming to IS 778: 1984, fixed as in repair complete all as specified and directed.
All as per serial item No. 39.00 here-in-before but of size 20mm bore -ditto-.
All as per serial item No. 39.00 here-in-before but of size 25mm bore -ditto-.
All as per serial item No. 39.00 here-in-before but of size 40mm bore -ditto-.
All as per serial item No. 39;00 here-in-before but of size 50mm bore -ditto-.
M & L for removing existing sludge from reservoir & depositing the sludge upto 100 m distance & cleaning , scrapping down deposit from floor & wall , washing the walls/floor with bleaching powder in the reservoir of following capacity, including writing work with synthetic enamel paint on the wall (capacity,date of cleaning, date of next cleaning, location etc.) complete all as specified & directed.
20 Lakhs gallon water supply installation
2.5 Lakhs gallon water supply installation
1 Lakhs gallon water supply installation
0.30 Lakhs gallon water supply installation
0.15 Lakhs gallon water distribution tank
Supply and fix in replacement Cast Iron Air Release Valves with double air Outlets, conforming to IS 14845 of size 80 mm dia bore and fixing up in seamless carbon steel pipe supply mains of size 150 mm dia complete all as specified and qty as per requirement and as directed by Engr-in-Charge.
All as per serial item No. 41.00 here-in-before but of size 100mm dia bore -ditto-.
All as per serial item No. 41.00 here-in-before but of size 150mm dia bore -ditto-.
S & F in repair/replacement Steel reinforced compressed asbestos fibre gasket of 3.0 mm thickness for 150mm nominal size pipes comprising of suitable holes for attachments, complete all as specified and directed by Engr-in-charge.
M & L for clearing away all the grass vegetation, saplings, shrubs, creepers, undergrowth, and roots, cleaning the area and removing rubbish upto a distance of 50 metres outside the periphery at various locations under AOR all as directed by Engr-in-charge.
Taking out old unsv and Supply installation and testing of Auto Transformer starter panel of capacity 125 HP with Cubical type ATS Starter panel made of Techno Modular construction with CRCA sheet steel suitable for 415 V, 3 phase, 4 wire 50 Hz AC supply system. Having required front surface area, fabricated in Fully compartmentalized design from CRCA sheet steel of 2mm thick for frame work & covers, 3mm thick for gland plates i/c cleaning & finishing complete with 10 tank spray based tricationic phosphating treatment process for powder coating in approved shade, PU Foam Gasket without manual pasting, joint less (temperature withstand capacity -400C to +1200C) for maintain IP protection complete with automatic phase corrector 400 Amp 3P Contactor-02 Nos with MCCB TP 250 Amps 36 kA with rotory handle -01 No, having adjustable tapping 50%, 65% and 80% four starts per hour. Power contactors-03 Nos of capacity 400A, 300A and 200A, BOCR 3DE electronic over current relay, phase & motor on/off/trip indications and all other standerd fittings for ATS, with digital volt meter (96x96) mm, 0-500 Volts and digital ammeter complete all as specified and as directed by Engineer-in-Charge including taking down the existing starter panel. Note : (i) The entire panel shall be mounted on MS base frame grouted in PCC foundation as per OEM size and specification. (ii) Ground clearance height of the panel shall be maintained as per OEM for cable entry incl glands.
Supply, laying, jointing and testing replacement PVC insulated cable 1100 volt grade with multi stranded, single core copper 95 Sqmm, Grade As Per IS 7098 (Part -1) 1988 including making electrical connection for main panel, to starter and starter to motor in pieces of suitable length as per site requirement duly fixed with suitable size of copper lugs/thimbles complete all as specified and as directed by Engr-in-charge.
All as per Srl Item No. 47.00 above but single core copper 120 Sqmm complete all as specified and as directed by Engr-in-charge.
All as per Srl Item No. 47.00 above but single core copper 185 Sqmm complete all as specified and as directed by Engr-in-charge.
S & F in replacement Copper Thimble of below mentioned sizes complete all as specified and directed by Engineer in charge.
S&F MCCB 630 Amps 4 pole, 50 KA, 415 V, 50 Hz with thermal setting between 70% to 100%, adjustable type and connecting up in the existing panel location including taking out existing unserviceable MCCB complete all as specified and as directed by Engineer-in-charge.
All as per Srl Item No. 51.00 above but MCCB of capacity 400 Amps 4 pole, complete all as specified and as directed by Engineer-in-charge.
All as per Srl Item No. 51.00 above but MCCB of capacity 200 Amps 4 pole, complete all as specified and as directed by Engineer-in-charge.
Amount of credit of Rs. 152931.000 for retrived old material as mentioned in Schedule 'A' section-II of tender document in pdf form, will be deducted offline while acceptence of tender.
Ayushmat Contractors
R B TRADERS
Pankaj Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .