Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹4,660 RAMGARH AT PO CHALNPUR DISTRICT RAMGARH 829 134 91 7 25077 4971 | ₹4,660 |
Tender Value
Refer Docs
EMD Value
₹5.2 L
Closing Date
28 Jul 2022, 11:00 amClosed
Supply, Installation, Testing & Commissioning of Grid interactive Roof Top Solar Power Generation system at Nauroji Nagar, New Delhi including operation and comprehensive maintenance for two years
NBCC-SrED-Nauroji-1-2022
NBCC-SrED-Nauroji-1-2022
Open Tender-Domestic
Electrical Work
New Delhi, Delhi
₹11,800
₹5.2 L
24 Jul 2026
6 Jul 2022
28 Jul 2022
28 Jul 2022
27 Oct 2022
SCHEDULE OF WORK/BILL OF QUANTITY (BoQ)
Rate Amount Amount (Non-
S.No. DSR/NS Description Qty Unit (Non-DSR)
(DSR) Rs. (DSR) Rs. DSR) Rs.
Supply, Installation, Testing and Commissioning of ongrid Solar Photo Voltaic
Power Plant conforming to MNRE specifications as amended, consisting of Mono/
1 Poly Crystalline silicon solar cells, net metering facility, necessary protections,
earthing, mounted on Aluminium/ GI structure of suitable strength with following
components complete as required:-
Solar Photovoltaic Module of capacity 330Wp or above, manufactured in India,
conforming to IS14286/ IEC 61215, IS/ IEC 61730-Part-1, IS/ IEC 61730-Part-2.
Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV
modules used in solar power plants/ systems must be warranted for their output
Delhi peak watt capacity, which should not be less than 90% at the end of 10 years and
Schedule of 80% at the end of 25 years.
Rates & Power Conditioning Unit (PCU) of 350-800V DC Input voltage range and 400V AC,
Delhi Analysis three phase, 4 wire, 50Hz +/-2.5Hz, output voltage suitable to generate AC Power
b) of Rates with efficiency not less than 97%, total harmonic distortion less than 3% and
(E&M) suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the
(Item for Solar voltage and frequency level to suit the Grid Voltage Frequency.
c) Data Monitoring System complete with accessories.
Fixing of Array junction box & Main junction box with IP65 protection and
d) termination arrangement for incoming and outgoing cable along with glands, lugs
and other accessories etc. as required.
e) Lightning and surge voltage protection.
Connections & Interconnections by supplying & fixing required size XLPE insulated
copper conductor 1.1kV grade armoured power and control cables between solar
f) modules, main power cable to grid supply PCU unit along with supplying & fixing of
necessary channel/ conduit lugs and other accessories etc. as required.
Complete system as specified above 800 KW 61060 4,88,48,000
Operation and Maintenance services for two years commencing from the day of
taking over certificate including deputating staff of different trades and maintaining
the entire system (GRID spv power plant) and installations as enshired in
respective caluse(s) of tender document, complete job in alll respects
Digitally signed by
AJAY AJAY KUMAR JAIN
GRAND TOTAL [S.No.1 + S.No.2 above] 5,17,78,880
GRAND TOTAL [S.No.1 + S.No.2 above] 5,17,78,880
KUMAR JAIN Date: 2022.07.06
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT.pdf
Tender Document
SCC.pdf
Tender Document
CS_cover_2_QuotingsheetPG.xlsx
Tender Document
ApprovedMake.pdf
Tender Document
BoQ.pdf
Tender Document
GCCcontractingInclAmend1to17compressed.pdf
Tender Document
IP.PDF
Tender Document
TechSpecs.pdf
Tender Document
DRG1TowerABCterracefloorplans.pdf
Tender Document
DRG2TowerDandETerraceplans.pdf
Tender Document
DRG3SOLARSCHOOLTERRACEFLOORPLAN.pdf
Tender Document
corrigendum-865-SPVCorrigendum2.pdf
pdf • 0.20 MB
corrigendum-856-CORR01TimeExtnSPV.pdf
pdf • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .