| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.7 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹48.1 L+₹11.3 L (30.9%)Rejected-Finance | L2 | Rejected-Finance Quoted amount is more than L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Wrong DD submitted. |
Tender Value
₹34.3 L
EMD Value
₹68,600
Closing Date
17 Jan 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Sahil Ratusaria, IDSE
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
CERTAIN SPL REPAIR, MINOR WORK AND REV WORK AT JAMSHEDPUR UNDER GE RANCHI
2023_MES_634068_1
8200/1523/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class D Cat a (i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹68,600
Yes
1 Mar 2024
22 Dec 2023
19 Jan 2024
23 Dec 2023
17 Jan 2024
4 Jan 2024
Amount
Demolition of brick work built in cement mortar, complete all as specified and directed.
M&L brick work using sub class B bricks straight of curved on plan exc 6m mean radius built in CM (1:6), complete all as specified and directed.
M&L rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:4) on wall finishing the surfaces even and fair without using extra cement, complete all as specified and directed.
M&L applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new plastered surfaces on walls over 2 mm thick wall care putty, complete all as specified and directed.
Roughening sufaces of old concrete floor by picking , sweeping clean and washing down with water to remove dust.
M&L rendering 15 mm thick Screed bed or bedding layer for laying floor finishes on fair faces of bricks/concrete surface in cement mortar (1:6) complete all as specified and directed.
M&L rendering 10 mm thick as backing coat to receive the tiles on fair faces of bricks/concrete surface in cement mortar (1:4), complete all as specified and directed.
M&L non skid coloured ceramic tiles 7 to 8 mm thick(square/rectangular) area of each tiles exceeding 0.11 sqm but n.exc 0.18sqm infloor etc;set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces complete all as specified and directed.
All as per above item No 8 but on vertical surface as dado/ skirting.
Excavation in post holes( or similar holes) each n exc 0.5cum each getting out, returning, filling in and ramming earth or broken rubble mixed with earh around , in layers n exc 25cm, watering and removing surplus soil to a distance n exc 50m and making good surfaces in soft/ loose soil, complete all as specified and directed.
M&L PCC 1:3:6 type C-2 using 40mm graded aggt. as in foundation ,filling and mass concrete with necessary form work complete all as specified and directed.
S&F mild steel posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc) including and all necessary drilling, bolting and riveting etc and similar work conforming to Fe-290 or Gde E-165, complete all as specified and directed.
S&F MS screw bolts (machine made) with hexagonal or square heads at one end and screwed with the other end each screwed end to be fitted with washers and one hexagonal or square nut n. exc 5 cm long of diameter of shanks 11 to 15 mm, complete all as specified and directed.
M&L MS round bars 10 mm dia and over cut to length, bent to shape required including cranking bending,painting and fixed with chain link fence conforming to Fe-410-0 complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type of standard, rails, straining bolt etc. including provn of binding wire complete all as specified and directed.
Supply only 3 mm Dia GI wire 100 x 100 mm mesh,(chain link fencing) made up into mattresses, or cages lapped wired and laid in position including closing and binded and tied with RCC posts properly complete all as specified and directed.
S&F GI barbed wire 2 strands 3 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts including sewing or tying with GI wire all as shown on drgs. (Each line wire to be measured) complete all as specified and directed.
M&L prepration of new steel surface not other wise described over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide
M&L applying two coat of black japan paints over one coat of red oxide primer on steel surfaces n.exe 10cm in width or girth including preparation of surfaces complete all as specified and directed.
M&L cleaning the inner surface of the walls and Applying Two coats of Sika Topseal 107 or Aqua Arm Top Guard a two components ready to use polymer modified cementitious coating inside of the walls & floor of the tank, first Coat should be applied horizontally and second coat should be applied vertically The thickness of coating shall not be less than 1.5 mm complete all as specified and directed.
M&L Applying two coats of AquArm Tank Coat a water based epoxy coating certified for portable water on all over the concrete surface from inside.Apply the first coat by brush allow it to dry for 6-8 hrs and then apply 2nd coat and allow it to cure complete 24 hrs The coating shall be applied using brush application. The Thickness after two coating should not be less than 500 microns complete all as specified and directed. 195.00 Sqm Sterilizing the total surface by applying Terbac-G5, TERBAC-G65& Ultraviolet Ray Ejector, bugger should be for uniform fog generation of Terbac-G5 & Terbac-G65, using High Pressure Jet Pump and industrial Vacuum Cleaner to complete the sterilization procedure. Government Laboratory test report of the sterilization chemicals should be submitted to the office before sterilization and sterilization certificate will be submitted to the office after sterilization.
M&L Examining concrete by tapping with light hammer and marking of the loose concrete areas of structural elements in straight line geometrical forms, grooving the edges same with grinder upto 5 -10mm depth without damaging existing rebars, carefully removing unsound weak/ loose concrete/ cover & concrete around the rebars upto 10 mm depth by low impact high frequency hammer/ chipper without damaging the sound concrete, daily cleaning and stacking of debris at prescribed location in polypropylene/ paper bags, disposing off the debris so generated on weekly basis outside the premises, etc, complete all as specified and directed necessary scaff -folding complete all as specified and directed.
M&L for cleaning existing reinforcement with wire brush/rotary wire brush to make surface free from rust scales, loose material, dirt etc complete and applying two coats of alkaline rust converting primer Re Arm Rust Remover with brush on the existing rebar for complete wetting of rusted metal surface and allowed to react it or 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal / steel for about 5-7 days including surface preparation. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth, complete all as specified and as directed. (Note: Work to be executed by the authorized specilized agency rays cleantech/ Inus watertech/ Satya Enterprises)
M&L Providing and Application of Sika Friazinc/ Aqua Arm Coat -Zp as passivator/ Anti corrosion coating to the steel reinforcement shall be applied The material shall be two component,cement based polymer modified two component coating for corrosion protection. The material shall be prepacked and ready to use. It shall be fully compatible with the reinstatement methods adopted complete all as specified and as directed by Engr-in-charge.This shall include surface preparation and errection of steel porps as required for the application. complete all as specified and directed. (Note: Work to be executed by the authorized specilized agency rays cleantech/ Inus watertech/ Satya Enterprises)
M&L of two component solvent free epoxy bonding agent Sika Sikadur 32LP/ Re Arm Superbond or equivalent for bonding old to new concrete . The ready to use epoxy bonding agent shall be applied over old concrete using brush after cleaning of surface of all dust or latiance.The material is supplied as a two part material in preweighed quantities for ready onsite mixing and use. The material shall exhibits the following properties Compressive strength 50 N/mm2 at 7D Flexural strenght 35N/mms at 7 D , Shear strength ION/mm2 at 7D and Tensile strength 20 N/mm2 and Bond Strength of ION/mm2.The new concrete shall be placed within the open time as specified by the manufacturer to ensure maximum bonding and application shall be as per the manufacturer instruction , complete all as specified and as directed by Engr-in-charge. Note: Work to be executed by the authorized specilized agency rays cleantech/ Inus watertech/ Satya Enterprises.
Rebuilding the section of damaged RCC elements to its original size in thickness of 25mm by hand or spray application by Providing and applying Sika MonoTop@- 122F single component, fibre reinforced, sulphate resistant, low shrinkage, high performance cementitious structural repair mortar or by micro concreting in the ratio of 1:2:4 added with water proofing admixture WP-10 or Sika Latex SBR, complete all as specified and directed.
M&L complete removal of existing treatment on walls and applying two coats of weather proof exterior emulsion of approved colour and shade over 2 mm thick wall putty complete all as specified and directed.
S&F in Repair cast iron sluice valve with flanged ends, confirming to IS-780 type PN-1.6 cast iron body with CI wheel brass spindle, joints with rubber gaskets including bolts nuts and washers complete with ISI mark size 100 mm CI line in position, all as specified and directed.
M&L providing cement concrete (1:2:4) type B-0 (Using 12.5 mm graded broken stone aggregate) as in coping and like including weathering slightly rounded or chambered agles and throathing and including necessary form work.
Demolition of cement concrete of any description and in any position complete all as specified and directed.
S&F GI barbed wire 2 strands 3 mm dia barbed with 2 mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails, straining bolts includig sewing or typing with GI wire all as shown on drgs. (Each line wire to be measured), complete all as specified and directed.
Preparation of new steel surfaces and two coat of synthetic enamel paint over a coat of red oxide primer.
M&L for preparation of old decorated surfaces on walls and applying one coat of cement based paint of approved colour and shade, complete all as specified and directed.
M&L including preparation of newly plastered wall surfaces and applying two coats of cement base paint of any colour over one coat primer, complete all as specified and directed.
Excavation in trenches not exc 1.5 mtr wide and not exc. 1.5 mtr deep for foundation in soft/loose soil & getting out.
Returning filling in trenches including spreading leveling and well ramming with water complete n.exc 25 cm thick in each layer in soft/loose soil.
Removing exavated soild n.exc 50 mtr and depositing where directed at a leve n. exc 1.5 mtr above the starting point.
M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick wall built in CM (1:4) Complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of bricks/concrete surface in cement mortar (1:6) on wall finishing the surfaces even and smooth without using extra cement.
M&L Damp proof course In cement concrete 1:2:4, type B-0 40mm thick to horizontal or vertical surfaces including nec- essary formwork
Supply only integral water proofing compound. (Make - ACCO PROOF/WATER SEAL/ IMPERMO)
S&F rolled mild steel as in Joist, channel, angle, or tee sections,fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe 410 -W (Gde- E- 250) quality A
S&F for pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.45mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall,fixed with self tapping srews all as specified and directed.
M&L for GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre incl 2mm dia G.I. ( upto 1200 mm length ) adjusting level to Purlins/ Rafter. .
M&L for 4mm thick non asbestos designer fibre cement building board of size 600X600 fixed or laid/inserted to timber/GI/Aluminium framework fixed in ceiling flat or sloping.
M & L cement concrete 1:4:8 type D-2, 75 mm thick as in sub base floors complete all as specified and directed.
M&L including preparation of new plastered wall surfacesand applying two coats of distemper oil emulsion over plaster of paris putty of 1mm thickness over chalk whiting complete.
M&L for preparing the new plastered surfaces of wall and applying Two coats of cement based paint complete all as specified and directed .
M&L prepration of new steel surface not other wise described over 10 cm width or girth and applying two coat of synthetic enamel paint over one coat of red oxide complete all as specified and directed.
M&L for 10 mm thick cement plaster in CM (1:4) for backing of tiles completeall as specified and directed.
M&L for coloured glazed ceramic tiles in vertical surface 300x600x7to8mm thick set and jointed in neat cement slurry & pointed in white or coloured cement to match the surfaces all as specified and directed.
M&L for 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
S&F Vitreous china Full pedestal wash hand basin of size 560 x 430 x 195mm with all accessories and fittings, complete fixed on brackets or erecting stand. Make- Jaquar Cat No.CNS-WHT-811,CNS-WHT-303 or equivalent .
S&F, vitreous china single piece water closet size 360x640x680 mm with soft close seat cover, Hinges,, fixing accesssories set , incl cistern fitting , connection to P trap, complete and making good to floor complete all as specified and as directed.
S&F Hand Shower (Health Faucet) with 1 Meter Long Easy Flex Tube in Chrome Finish & Wall Hook with all necessary accesories complete all as specified & directed. Make- Jaquar Cat No. ALD-565 or equivalent
S&F for 15mm Angular Stop Cock with Wall Flange with all necessary accesories complete all as specified & directed. complete all as specified and directed.Make Jaquar Cat No. OPP-15053PM or Equivlent
S&F two way Bib tap 15mm with Wall Flange and all necessary accesories complete all as specified and directed.Make Jaquar Cat No. OPP-15053PM or Equivlent
S&F stainless steel towel self 450mm long with lower hanger fixed completed all as specified & directed. ( Make-Jaquar Cat no AEC-ESS-1181NA or equivalent.
S&F towel ring squar with round flange fixed complete all as specified & directed.
S&F PVC connection 15mm size with PTMT Nuts of length 450mm complete all as specified and as directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wood grain colour PVC sheet reinforced with M.S. square tube, suppling & fixing in opening as per specification & drawing.
S & F factory made solid panel both side prelam PVC door shutter with feathered edge 30mm thick (style) consisting of frame made out of mild steel tubes for top & bottom rails, Mild steel frame shall be covered with heat moulded prelam coloured PVC ‘C’ channel having a PVC sheet strip of 30mm with steel inside with solvent cement for stiles and plain colour PVC sheet for top rails, lock rail & bottom rail on either side and as gap insert for top rail & bottom rail paneling of plain colour PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement, fixing in the frame at site as per specification, drawing and as directed (Rajshree brand or equivalent)
S&F anodised aluminium ventilator shutters fixed or louvered type without sash bar, aluminium section weighting not less than 0.55 Kg/M including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and 4 mm thick figured glass fixed in fram etc completed all as specified and directed.
Providing PCC jallies type B0,1:2:4 (12.5mm graded aggregate), 45mm thick, incl all moulding but excluding frame set in CM1:4.
M&L for 75mm thick PCC type C2 1:3:6 (using 40mm graded stone agg) as in plinth protection/Path/floor finishing surface of concrete topping even and fair without using extra cement complete.
S&F extruded aluminium alloy butt hinges 100mm size type B-21 all as specified & directed.
S&F Brass barrel tower bolts 100mm, with cast or sheet barrel and rolled or cast bolts and fixed
S&F Brass, sliding door bolt 200mm with sand or die-cast brass hasp,taple (bolt type) and fixing bolt with rolled or drawn brass bolts and fixed complete all as specified and directed.
S&F Extruded brass handles 100mm,fabricated type polished complete all as specified and directed.
M&L PCC 1:3:6 type C-2 using 40 mm graded stone agg for concrete bed to drain pipes including , packing under and haunding against the sides of pipe, after they tested for 150 mm dia pipe.
M&L for 150 mm dia of reinforced concrete pipe, class NP2, laid and jointed complete with collars as specified and directed.
S&F steel tubing and connection tubing in new or old position to walls, ceiling, floors etc including all fitting as socket,elbow,nipple,union etc complete all as directed at site for 15 mm bore all as specified.
All as per item No 73 above but for 20 mm dia
S & F PVC(SWR) 100 mm outlet dia floor trap, plain with grating in cluding jointing with solvent cement complete all as specified and as directed.
M&L RCC type B-I, 1:2:4 (20mm graded aggregate) as in slab
M&L for TMT bars 10 mm dia and over cut to length and bent to shape required including cranking, hooking ends and binding with and MS wire not less than 0.9 mm dia or securing with clips
S&F Rotational moulded polyethlene water storage tanks 1000 ltr in capacity (cylindrical vergical with closed top) hoisted and fixed in position all as specified in SSR Part I
S&F Gun-metal, golbe or gate valves,20mm Bore dia of pipe with iron wheel head, screwd both end sor iron pipe and fixed
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out soft/loose soil.
M&L 20mm thick Screed bed or bedding layer in cement mortar 1:6 for laying of floor tiles complete all as specified and as directed.
M&L coloured glazed chequered cement concrete tiles with grey cement and no pigment 30cm x 30 cm x 25mm thick set jointed and pointed in neat cement slurry in floors complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and paving n.exc 15cm thick (below or above ground level), complete all as speicified and directed.
M&L cement concrete type D-2, 1:4:8 (40 mm graded aggregate) 100 mm thick as in Sub-base of floor, complete all as specified and directed.
M&L machine pressed precast concrete interlocking paver block with grey cement and no pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade laid over sand cushioning, complete all as specified and directed.
M&L Sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed.
Material and labour providing cement concrete (1:2:4) type B1 (Using 20 mm graded broken stone aggregate) as in coping and like including weathering slightly rounded or chamfered angles and throathing and including necessary form work, complete all as specified and directed.
M&L for point wiring alongwith earth continuity conductor with 1100 volts grade PVC insulated and FR multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black, Earth - Green) FRLS grade dwawn in and including PVC casing and caping not less than 20mm size and fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.12 mm covered with 2.80 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators complete including 1.0 sqmm copper stranded earth wire for all as specified for the following :-
One light point controlled by one switch.
One fan point controlled by one switch.
One socket outlet 3 pin 5 Amp controlled by one switch on the same board.
One socket outlet 3 pin 5 Amp on independent board.
S&F in repair LED building Security light fitting 1x20watt with polycarbonate housing, Aluminum gear tray duly prewired inbuilt LED module IP 65 Protection complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable of size 1.5 sq mm including GI tubing 40mm dia light grade 1.5m long band to shape for mounting of security light with 2 nos MS,FI clamp including plinth with nut bolts etc complete all as specified and directed Make: Crompton Greaves/Havells/Philips.
M&L point wiring alongwith earth continuity conductor with 1100 volts grade PVC insulated FR multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black, Earth - Green) FRLS grade dwawn in and including PVC casing and caping not less than 20mm size and fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.12 mm covered with 2.80 mm thick phenolic laminated white sheet cover for one 6 Pin 15 Amp socket outlet controlled by one switch on independent board.Incl. 1.5 Sq mm copper conductor earth wire and connected to common earth dolly on independent board.
Supplying and fixing angle holder, insulated polycabonate body with back plate complete all as specified and directed.
Supplying and fixing switch piano flush button single pole one way 5/6 amp complete all as specified and directed.
Supplying and fixing switch socket combination two in one 5 and 15 Amps multipurpose flush type universal 240Volts, complete all as specified and directed. Make - Anchor / Leader / SSK.
Supplying and fixing socket outlet 2 in 1, 5 pin, 5/6 amp, flush type complete all as specified and directed.
Supplying and fixing switch socket combination two in one 5 Amps multipurpose flush type universal 240Volts.
Supplying and fixing ceiling rose 63 x 25 mm three terminals complete all as specified and directed.
Supplying and fixing integrated LED 9 watt complete all as specified and directed. Make - Philips or Osram or Wipro.
M&L Tube light fitting 1x 18 Watt LED box type complete with bipin holder electronic ballast suitable for fluorescent tube rod 4 feet long 18W and pre-wired up to main connection of PVC connector inside box include providing one 4 feet long fluorescent rod and providing copper flexible cord twin 0.5 Sq mm from ceiling rise to fitting.
S&F in repair service connection of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathed of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core multistandard cable flat or circular of 6 Sqmm 2 core including taking down old service cable complete all as specified & directed.
M & L in repair for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sq mm (FRLS) in PVC casing & capping non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 4 Sq mm (FRLS) of continuous earth wire green in colour complete all as specified and directed by Engineer-in-charge. (NOTE: Two runs of 6.0 sqmm cable & One run of 4 sqmm cable and One run of PVC casing & capping shall be paid as one unit length.)
S&F Exhaust fan 300 MM sweep including cutting and chesing ,making hole for fixing complete.model no-Turbo force of Havells
M&L Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size 32x 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as directed.
M/S Anjan Kumar Singh
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .