Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.9 LAccepted-AOC | ₹34.9 L Quoted ₹35.9 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹37.3 L+₹1.3 L (3.70%)Rejected-Finance MES COLONY KUMBHIGRAM AIRPORT CACHAR ASSAM 788109 | KUMBHIGRAM | CACHAR | ASSAM | 788109 | ₹37.3 L+₹1.3 L (3.70%) | L2 | Rejected-Finance Other than Lowest Bidder |
| 3 | L3₹38.7 L+₹2.8 L (7.72%)Rejected-Finance PRAGARI NAGAR BYE LANE 3 HOUSE NO 05 SATGAON UDAYAN VIHAR GUWAHATI 781171 | KAMRUP METRO | ASSAM | 781171 | ₹38.7 L+₹2.8 L (7.72%) | L3 | Rejected-Finance Other than Lowest Bidder |
| 4 | L4₹39.0 L+₹3.1 L (8.55%)Rejected-Finance SANTIPUR HILL SIDE PS BHARALUMUKH GUWAHATI 781 009 | KAMRUP METRO | ASSAM | 781009 | ₹39.0 L+₹3.1 L (8.55%) | L4 | Rejected-Finance Other than Lowest Bidder |
| 5 | L5₹44.8 L+₹8.8 L (24.6%)Rejected-Finance SUMATEE BHAWAN GUWAHATI AIRPORT NEAR BORJHAR TELEPHONE EXCHANGE GUWAHATI 781015 ASSAM | KAMRUP METRO | ASSAM | 781015 | ₹44.8 L+₹8.8 L (24.6%) | L5 | Rejected-Finance Other than Lowest Bidder |
Tender Value
₹49.6 L
EMD Value
₹99,300
Closing Date
13 May 2023, 6:00 pmClosed
GE Narangi
GE Narangi C/o 99 APO
CERTAIN DAY TO DAY INTERNAL ELECTRIFICATION WORKS OF VARIOUS MD OTM ACCN UNDER GE NARANGI
2023_MES_589647_1
8826/B/E8
Open Tender
Civil Works
Item Rate
180 days
GE Narangi
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE Narangi
₹99,300
Yes
23 May 2023
17 Apr 2023
15 May 2023
17 Apr 2023
13 May 2023
29 Apr 2023
Amount
Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but including switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed.
M&L for point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in and including PVC Casing and Caping with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screw for mounting switches, sockets, regulator etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one 5 Amps switch one way complete all as specified and directed.
All as per item No 2 here-in-before but for one 3 pin 5 Amp switch socket outlet on independent board
All as per item No 2 here-in-before but for one 3 pin 5 Amp socket outlet on same board with other switches.
All as per item No 2 here-in-before but for one bell point controlled by one switch 5 Amps bell push on the same board with other switches or independent with cables
All as per item No 2 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
All as per item No 2 here-in-before but wiring with 4.00 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 4.00 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
M&L for point wiring with PVC insulated and unsheathed cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts, FRLS grade cable conforming to IS-694 1990 drawn in and including PVC rigid conduit ( concealed) with all accessories including febricated MS/PVC terminal boxes fixed flush with wall surface with 3mm thick masonite laminated sheet top cover fixed with brass screws for mounting switches, sockets, regulators etc including 1.5 sqmm single core PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one 5 Amps switch one way complete all as specified and directed.
All as per item No 8 here-in-before but for one 3 pin 5 Amp switch socket outlet on independent board
All as per item No 8 here-in-before but for one 3 pin 5 Amp switch socket outlet on same board with other switches.
All as per item No 8 here-in-before but for one bell point controlled by one switch 5 Amps bell push on the same board with other switches or independent with cables
All as per item No 8 here-in-before but wiring with 2.5 sqmm size single core multistranded copper conductor cable for 6 pin 15 Amps switch socket combination outlet on independent board with 2.5 sqmm PVC insulated and unsheathed copper conductor as earth and connected to earth dolly.
S&F in repair modular switch one way 6 Amps 1 module complete all as specified and as directed.
S&F in repair modular switch one way 16 Amps 1 module complete all as specified and as directed.
S&F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
S&F in repairs, switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
S&F in repairs, switch piano, flush type single pole one way 15 Amps 230 volt complete all as specified and as directed.
S&F bell push, flush type, 5 Amps complete all as specified and as directed.
S&F in repairs, modular bell push, 6 Amps 1 module complete all as specified and as directed.
S&F in repair modular socket 6 Amps 2/ 3 pin, combined 2 module complete all as specified and as directed.
S&F in repair modular socket 16 Amps 2/ 3 pin, combined 2 module complete all as specified and as directed.
S&F socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and as directed.
S&F in repairs, socket outlet 3 pin, 2-in-1, 5 Amps flush type complete all as specified and as directed.
S&F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
S&F in repairs, switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
S&F switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
S&F in repairs, switch socket combination multipurpose, 2 in 1, 6 pin, 5 & 15 Amp flush type complete all as specified and as directed.
S&F lamp holder insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed.
S&F in repairs, lamp holder insulated, PVC / polycarbonate /bakelite body complete all as specified and as directed.
S&F stepped type electronic fan regulator, two module size, flush type complete all as specified and directed.
S&F in repairs,stepped type electronic fan regulator, two module size, flush type complete all as specified and directed.
S&F ceiling rose surface bakelite 65x50mm three terminal complete all as specified and as directed.
S&F in repairs, ceiling rose surface bakelite 65x50mm three terminal complete all as specified and as directed.
S&Fsingle pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp 240 V complete all as specified and as directed.
S&F call bell Ding Dong AC ,230 volts single pole complete all as specified and as directed.
S&F in repairs, modular fan regulator 120 W-2 module complete all as specified and as directed.
S&F in repairs, modular cover plate white with frame , 1 module all as specified and as directed.
S&F in repairs, modular cover plate white with frame , 2 module all as specified and as directed.
S&F in repairs, modular cover plate white with frame , 3 module all as specified and as directed.
S&F in repairs, modular cover plate white with frame , 4 module all as specified and as directed.
S&F in repairs, modular cover plate white with frame , 6 module all as specified and as directed.
S&F in repairs, modular cover plate white with frame , 8 module all as specified and as directed.
S&F in repairs, modular cover plate white with frame , 12 module all as specified and as directed.
S&F in repairs, metal flush box 1/2 module all as specified and as directed.
S&F in repairs, metal flush box 3 module all as specified and as directed.
S&F in repairs, metal flush box 4 module all as specified and as directed.
S&F in repairs, metal flush box 6 module all as specified and as directed.
S&F in repairs, metal flush box 8 module all as specified and as directed.
S&F in repairs, metal flush box 12 module all as specified and as directed.
S&F in repairs, LED batten type fitting pre-wired including LED tube 1 x 20 W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable complete all as specified and as directed.
S&F in repairs, LED box type fitting pre-wired including LED tube 1 x 20 W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable complete all as specified and as directed.
S&F in repairs, decorative hexagonal bulk head LED luminaire 10 Watt, 6000K with IP 66 protection complete all as specified and as directed.
S&F in repairs, LED light fitting mirror type with high out put diffuser 2 feet, 10 Watt, 220 V AC with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size
S&F in repairs, LED 40W post top made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection suitable for dia upto 60mm complete.
S&F in repairs, wall decorative fixtures in durable body and designer mesh in gold finish suitable for 8/10 Watt LED lamp of B-22, including lamp of 8/10 Watt.
S&F in repairs, wall decorative fixtures in durable body and designer mesh in gold finish suitable for 9 Watt LED lamp of B-22, including lamp of 9 Watt.
Disconnecting the main power supply to distribution box and making proper dressing of SPN/TPN/VTPN MCB/MCCB DBs of preconnected MCBs by replacing screws of DB covers, earth wires, and other necessary connecting items and dressing of wires inside the DB with cable tie complete all as directed.
S&F in repairs, LED bollard light 9 W LED bollard with opal acrylic diffuser and IP 65 protection suitable for dia upto 60mm.
S&F in repairs, 15W LED recessed mounted luminaire with high brightness LEd for glare free homogenous illumination suitable for armstrong/grid ceiling and fixture size in mm ( 295X295X70mm) complete all as specified and as directed.
S&F in repair LED surface mount downlighter 15W with pressure diecast aluminium heat sink and PC diffuser in white powder coated finish with integrated driver and connecting up with three core flexible copper conductor cable of suitable size complete all as directed.
S&F in repair LED luminaire 600X600mm, 35/36 Watt, 220V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders and LED lamps suitable for roof ceiling including connecting up with three core flexible copper conductor cables of suitable size complete all as directed.
S&F in repairs, LED35 W building security light made up of pressure die cast housing with high efficient LED as lighting source and PC cover having TOP Opening separate driver compartment with IP66 protection and impact resistance of IK07 and suitable for dia upto 43 mm complete all as specified and as directed .
M&L for building secruity light bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape for fixing street light luminaries all as directed, length of GI Pipe shall not be less than 2.0 mtrs complete all as specified and directed.
S&F in repairs, iron cage in straight designer mesh suitable for required size of gate light with proper fixing and making provision of suitable size GI pipe for fixing of gate light as directed .
S&F in repairs, factory made, sheet steel distribution boards, TPN, 4 Way, protection class IP-43 with min 100 Amp rating copper bus bar, provision for FP MCB as incomer and SP MCBs as outgoing complete and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate complete all as specified and as directed .
S&F in repairs, factory made, sheet steel distribution boards, IP-43 of double door VTPN 4 way with 250 Amps rated copper bus bar 415 volt and grouted in wall with PCC(1:2:4) type B-1 using 20 mm graded stone aggregate.
S&F in repairs, single pole & neutral DBs, 4 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar grouted in wall in PCC 1:2:4 type B-1 complete all as specified and as directed.
S&F in repairs, single pole & neutral DBs, 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar grouted in wall in PCC 1:2:4 type B-1 complete all as specified and as directed.
S&F in repairs, MCCB four pole 63A, Icu16KA, thermal magnetic, 415v AC complete all as specified and as directed.
S&F MCCB four pole 63A, Icu16KA, thermal magnetic, 415v AC complete all as specified and as directed.
S&F MCCB four pole 100A, Icu16KA, thermal magnetic, 415v AC complete all as specified and as directed.
S&F in repairs, MCCB four pole 100A, Icu16KA, thermal magnetic, 415v AC complete all as specified and as directed.
S&F in repairs, MCB TPN of capacity 40A to 63A,10 KA, type 'C' curve, 240 Volts, complete all as specified and as directed.
S&F MCBs, SPN 32 Amps, 240v 10 KA, 'C' curve complete all as specified and as directed.
S&F MCBs, SP 6 to 32 Amps, 10 KA, IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.
S&F of Exhaust fans AC single phase 230/ 240 V ,50 Hz metallic heavy body of size 300 mm sweep, 1400 RPM with louver fixing with 4 no hold fastener nut and bolt with washer and connecting with flexiable PVC insulated multistranded copper conductor cable of size 1.5 sqmm including civil work opening on wall of suitable size and 400x400x6mm thick BWR graded plywood making suitable hole for fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and writing MES No. with black synthetic enamel paint with 2cm high letter and making good surface complete all as specified and directed.
S&F in repair wall fan AC single phase 230/240 V , 50Hz, metallic heavy body of size 400mm sweep including necessary connecting up with PVC flexible insulated multistranded copper conductor cable of size 1.5 sqmm and making good disturbed surfaces complete.
Taking down fan of any type/make and size of AC ceiling fan, carefully from fan hook, and transporting from any location inside army area to MES E/M store yard, and refixing on same location or other location after repairing/painting complete all as specified and as directed.
M&L for applying one coat of synthetic enamel paint to ceiling/exhaust fan including preparetion of surface by using spray painting machine complete all as specified and as directed.
Strip opening of ceiling fan 1200 /1400 mm sweep, cleaning thoroughly bush & ball bearing by petrol, washing/cleaning fan blades with caustic soda thoroughly, provision of fresh greasing, replacement of worn out/defective unserviceable parts (wherever necessary) reassembling the same and testing the fan on full load to entire satisfaction of Engineer-in-Charge. Note:- Replacement of defective/ unserviceable parts shall be measured and paid separately in respective items as supply only.
Cutting the existing copper winding of AC ceiling fan 1200 mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 meters long size 24/0, 020 (ISI marked) all insulating materials including varnishing, heating and drying complete including satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
Cutting the existing copper winding of AC ceiling fan 1400 mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 meters long size 24/0, 020 (ISI marked) all insulating materials including varnishing, heating and drying complete including satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
Cutting the existing copper winding of AC ceiling fan 1200/ 1400 mm sweep heavy duty old model and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 meters long size 24/0, 020 (ISI marked) all insulating materials including varnishing, heating and drying complete including satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
Supply only ball bearing of size 6201/6202 for any type/make of ceiling fan 1200/1400 mm sweep all as directed. (Make : NBC/SKF/SBBI)
Supply only fan capacitor 2.5 Mfd suitable for 1200/1400 mm sweep ceiling fan all as directed. (Make : NBC/SKF/SBBI)
Supply only rubber reels including shackle clamp, bolts, nuts, washers split pins of appropriate size as required.
Supply only down rod 15mm dia GI pipe heavy duty 45 cm long including machining/ threading/drilling hole of size suitable for nuts and bolts washer and split pin suitable for any size and make of fan.
Supply only plastic canopy upper & lower of any size and make of ceiling fan fixed with suitable size of screws complete all as specified and as directed.
Taking down exhaust fan of size 200mm to 450mm sweep of any make and transporting from any location inside army area to MES E/M store yard, and refixing on same location or other location carefully after repairing, washing by petrol ,greasing, replacement of worn out/defective unserviceable parts (wherever necessary) assembling the same including provision of twisted twin core flexible wire upto 0.7 meters long size 24/0, 020 (ISI marked) and testing the fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and as directed. Note :- Note:- Replacement of defective/ unserviceable parts shall be measured and paid separately in respective items as supply only.
Taking down wall fan of size 200mm to 400mm sweep of any make and transporting from any location inside army area to MES E/M store yard, and refixing on same location or other location carefully after repairing, washing by petrol ,greasing, replacement of worn out/defective unserviceable parts (wherever necessary) assembling the same including provision of twisted twin core flexible wire upto 0.7 meters long size 24/0, 020 (ISI marked) and testing the fan on full load to entire satisfaction of Engineer-in-Charge complete all as specified and as directed. Note :- Note:- Replacement of defective/ unserviceable parts shall be measured and paid separately in respective items as supply only.
Cutting the existing copper winding of AC exhaust fan 200mm to 300mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 mtrs long size 24/0, 020 (ISI marked) all insulating materials incl varnishing, heating and drying complete incl satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
Cutting the existing copper winding of AC exhaust fan 450mm sweep and rewinding the armature (Rotor) with super enamelled copper wire of suitable size including provision of twisted twin core flexible wire upto 0.7 mtrs long size 24/0, 020 (ISI marked) all insulating materials incl varnishing, heating and drying complete incl satisfactory testing of fan on full load to entire satisfaction of Engineer-in-Charge.
Supply only ball bearing suitable for exhaust fan upto 450mm sweep all as directed. (Make : NBC/SKF/SBBI)
Supply only condenser ISI marked 230/240/250 volts AC 4 Mfd suitable for exhaust fan including condenser spacer and soldering of condenser wire to fan wire (Make : Usha/Asian/EPCOS/Universal).
S&F in repair cable junction box of size 130X130X77mm, IP -66 with metric knockout for cable entry ( Dust and power jet proof as per IEC60529) shock proof, rust free, corrosion free acid and chemical resistant, fire retardent having high impact (IK08) totally insulated ( ClassII) made of helogen and silica free recyclable material UV resistant having high grade gasket made of polyurethene, one no. MCB DP ^Amps with locking arrangement and M40 size cable gland and one M32 size gland suitable for 2.5- 6.0 sqmm cable complete.
S&F in repairs 1100 Volts grade heavy duty flat cable of size 4.00 sqmm 2 core, PVC insulated aluminium stranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connection supported by 4mm dia suspension wire complete all as specified and as directed.
M & L for Sub main wiring with 2 runs of 1.50 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia non metallic PVC grey conduit conforming to IS-9537 with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 1.50 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduitcomplete all as specified and as directed. Note : Three runs of cable and one run of PVC conduit will be measured as one Rm unit.
M & L for Sub main wiring with 2 runs of 2.50 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia non metallic PVC grey conduit conforming to IS-9537 with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 2.50 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduitcomplete all as specified and as directed. Note : Three runs of cable and one run of PVC conduit will be measured as one Rm unit.
M & L for Sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia non metallic PVC grey conduit conforming to IS-9537 with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduitcomplete all as specified and as directed. Note : Three runs of cable and one run of PVC conduit will be measured as one Rm unit.
M & L for Sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20 mm dia non metallic PVC grey conduit conforming to IS-9537 with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 4 sqmm single core PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of conduitcomplete all as specified and as directed. Note : Three runs of cable and one run of PVC conduit will be measured as one Rm unit.
M&L for earthing complete with GI earth plate electrode of size 60cm x 60cm x 6.3mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level sorrounded from all sides by 15cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including 4mm dia GI wire upto 7.5 m by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 15mm dia GI pipe connected to main control board and GI pipe medium grade 20mm bore for watering and including funnel, wire mesh, charcoal,salt etc RCC pit cover flush to earth pit 50mm thick reinforced with 8mm TMT bar 100mmC/C and PCC chamber pit with PCC (1:3:6) type C1 (using 20mm graded aggregate) including excavation and earthwork disposal of surplus soil to distance not exceeding 50 metre) and testing after completion including demolition of old earthing all as specified and shown on plate No 3 of SSR Part-I 2009 complete all as specified and as directed.
Goswami Traders
MAC ENGINEERS
SWASTIKA ENGINEERS AND AGENCIES
Ms Sukumar Talukdar and Co.
M/S VSL INFRA & TRADE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .