Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.8 LAccepted-AOC 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | ₹89.8 L Quoted ₹89.9 L | L1 | Accepted-AOC BEING LOWEST |
| 2 | L2₹96.0 L+₹6.1 L (6.84%)Rejected-Finance HIMACHAL BUILDING SHOP NO 10 CD BARFYWALA ROAD JUHU LANE ANDHERI W MUMBAI 400058 | MUMBAI SUBURBAN | MAHARASHTRA | 400058 | ₹96.0 L+₹6.1 L (6.84%) | L2 | Rejected-Finance NOT LOWEST |
| 3 | L3₹1.0 Cr+₹13.0 L (14.4%)Rejected-Finance | ₹1.0 Cr+₹13.0 L (14.4%) | L3 | Rejected-Finance NOT LOWEST |
| 4 | L4₹1.0 Cr+₹13.6 L (15.1%)Rejected-Finance 12 BHARTI AARTIST COLONY VIKAS MARG NEW DELHI 110092 | EAST | DELHI | 110092 | ₹1.0 Cr+₹13.6 L (15.1%) | L4 | Rejected-Finance NOT LOWEST |
| 5 | L5₹1.1 Cr+₹15.7 L (17.5%)Rejected-Finance | ₹1.1 Cr+₹15.7 L (17.5%) | L5 | Rejected-Finance NOT LOWEST |
| Sl No | Description | Qty | Unit | Electromech Engineers L6 | Vijaypower Generators Limited L4 | DIVYA ELECTRIC CORPOORATION L3 | UNITED ENTERPRISES L5 | M/s PIONEER CONTRACTORS L2 | Roy and Sons Infrastructures L1 | SBS Enterprises L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking out unserviceable DG Set 200 KVA from Waldevi Pump House and shifting it to MES Yard at Arty Center complete all as directed by the Engineer - in - Charge.
Note :- Quotated rates includes all T & P required for for the shifting of DG Set | 2 | Each Job | 19,000 ₹38,000 | 15,000 ₹30,000 | 10,000 ₹20,000 | 7,000 ₹14,000 | 5,400 ₹10,800 Lowest | 12,000 ₹24,000 | 30,000 ₹60,000 |
| 2.00 | Taking out unserviceable DG Set 320 KVA from Waldevi Pump House and shifting it to MES Yard at Arty Center complete all as directed by the Engineer - in - Charge.
Note :-Quotated rates includes all T & P required for for the shifting of DG Set | 1 | Each Job | 19,000 ₹19,000 | 18,000 ₹18,000 | 10,000 ₹10,000 | 11,000 ₹11,000 | 6,300 ₹6,300 Lowest | 13,500 ₹13,500 | 30,000 ₹30,000 |
| 3.00 | Supply, installation, testing and commissioning Diesel Engine driven generating set of capacity not less than 200 KVA/ 160 KW, 3 phase, 4 wire, 415 V, 50 Hz,1500 RPM, AC power supply with power factor 0.8 (lagging), coupled directly to alternator, mounted on a common base plate complete with integral acoustic enclosures (shall have salient features) modular bolted construction & pure polyester based coating to ensure long life in all weather conditions & for outdoor application / installation, integrated design thereby facilitating / easy handling. The design of integral acoustic enclosure shall be approved by National Physical laboratory as per central pollution control board (CPCB-IV +) latest regulation / norms (NOx+HC < 4.0, CO < 3.5, PM < 0.2 & smoke limit < 0.7 ) with fuel tank, battery & standard accessories, tools & spares as provided by manufacturer complete with necessary PCC foundations PCC foundation as per OEM/ manufacturer recommendation to bear the load of DG set having suitable size including excavation and earth work with block masonry work and plastering all as specified and as directed:- | 2 | Each | 30,00,000 ₹60,00,000 | 29,86,002 ₹59,72,004 | 29,00,000 ₹58,00,000 | 30,70,000 ₹61,40,000 | 28,00,800 ₹56,01,600 | 24,93,000 ₹49,86,000 Lowest | 31,00,000 ₹62,00,000 |
| 3.01(I) ENGINE- Efficient CRDI System, designed & tested for 50 degree ambient temperature, Water cooled diesel engine at 1500 RPM, engine capacity suitable for 200 KVA output ,415 V,50 Hz, No of cylinder- 06 Nos consists of direct injection, turbo-charged, four stroke liquid cooled technology confirming to BS : 5514 and IS :10000 suitable for prime duty generating set. Alternator under NTP conditions with provision of 10 % over load for 1 hour confirming to latest CPCB norms .The Engine shall consist of the following:- (a) Dry type air cleaner (b) Exhaust silencer (c) Expansion bellows (d) Lube oil cooler (e) Lube oil filter (f) Radiator, radiator fan and mounting (g) Fuel pump, with governor (h) Fly wheel with starter ring (j) Battery charging alternator with suitable capacity (k) electric starter motor of suitable Volts as per OEM | ||||||||||
| 3.02Engine Monitoring system :- The genset monitoring and safety system, having following features :- (a) Controller Microprocessor based ,Graphical LED display,integrated with AMF,Synchorinisation & Communication compatable , Control panel consisting of built in ON/OFF/start key (b) Battery charging voltmeter. (c) Electronic hour meter. (d) Indication & Monitoring of oil pressure & safety trip in case of Low oil pressure. (e) Indication & Monitoring of coolant temperature & safety trip in case of high coolant temperature. (f) In-built engine shut down system in case of engine over speed. (g) Indication & Monitoring of fuel level and alarm. | ||||||||||
| 3.03(II) BRUSH LESS ALTERNATOR:- Alternator suitable rated for 200 KVA DG at 0.8 PF, 415V, 3 phase, 4 wire, 50 cycles/sec, 1500 RPM, self excited and self regulated, with Brushless Excitation Band of voltage regulation + 1% of rated voltage, from NO load to full load, Insulation class "H". The alternator generally conforms to BS : 2613/ IS : 4722 (III) BATTERY:- Heavy duty battery of suitable AH and Nos connected to the system fully charged including lead and battery terminals complete of Make as provided by OEM | ||||||||||
| 3.04(IV) STANDARD CONTROL PANEL The control panel with aluminium bas bar, bottom entry and exit of cable made of sheet steel duly painted with stove enamel paint consists of followings :- (a) 01 No MCCB of suitable rating. (b) 01 No, EMS (c) 03 Nos Current Transformer (d) 02 Nos indicating lamps (e) 01 set control fuses (f) 01 No KWh meter | ||||||||||
| 3.05(V) DEF Tank:- (a) DEF/ Aqueous urea to sets off the chemical reaction with Exhaust gas (b) Tank size is optimized in accordance to DEF consumption (VI) Exhaust Gas Treatment System (a) DOC & SCR system sets off the reaction to meet the latest CPCB norms (b) Reduction in NOx & HC ,Reduction in PM (VII) Supply Module & DCU:- Control & monitor the DEF | ||||||||||
| 3.06(VIII) AUTOMATIC MAINS FAILURE (AMF) CONTROL PANEL (DOUBLE CONTACTOR) The control panel will be free standing, , cubical type, outdoor type, front operated dust and vermin proof, fabricated out 3 mm thick CRCA sheet duly power coated after necessary pre-treatment process & consisting of following :- Power Circuit Mains DG Set 1 No 4P contactor suitable rated 1 No 4P contactor suitable rated 1 No 3P MCCB suitably rated 1 No 3P MCCB suitably rated Control & Metering Circuit 1 No Microprocessor based AMF logic controller 1 No KWh meter 1 No Line Voltage Monitor L&T Make. 1 set of control fuses 1 No static battery charger circuit with ON/OFF switch. Battery charger "ON" indication. Reserves Polarity indication. 1 No DC battery charging ammeter. | ||||||||||
| 3.07(IX) ONE SET OF ACCESSORIES COMPRISING OF:- (a) Fuel tank - Capacity of tank shall be to hold diesel sufficient for 08 hours running at full load, with following features: (i) Level indicator. (ii) drain plug . (iii) MS class 'C' piping for inlet from pump to tank to engine. (iv) Fuel strainer. (v) Air vent. (b) Base plate :- Fabricated out of MS channel's ISMC of suitable size suitable for fixing of DG set all specified by the manufacturer. (X) Necessary civil foundation works including excavation , PCC , and other requirements as required and as recommended by OEM. The Foundation shall be minimum of 400mm above the FFL. | ||||||||||
Tender Value
₹1.1 Cr
EMD Value
₹1.9 L
Closing Date
18 Jun 2026, 6:00 pmClosed
CWE DEOLALI
HQ CWE DEOLALI, ONSLOW ROAD, DEOLALI (MH) 422401
AS PER TENDER DOCUMENTS
2026_MES_766637_1
83750/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Nasik Road
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE Nasik Road
₹1.9 L
Yes
11 Sept 2026
20 May 2026
25 Jun 2026
20 May 2026
18 Jun 2026
11 Jun 2026
21 May 2026 - 3 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking out unserviceable DG Set 200 KVA from Waldevi Pump House and shifting it to MES Yard at Arty Center complete all as directed by the Engineer - in - Charge.
Note :- Quotated rates includes all T & P required for for the shifting of DG Set | 2 | Each Job | - | - |
| 2 | Taking out unserviceable DG Set 320 KVA from Waldevi Pump House and shifting it to MES Yard at Arty Center complete all as directed by the Engineer - in - Charge.
Note :-Quotated rates includes all T & P required for for the shifting of DG Set | 1 | Each Job | - | - |
| 3 | Supply, installation, testing and commissioning Diesel Engine driven generating set of capacity not less than 200 KVA/ 160 KW, 3 phase, 4 wire, 415 V, 50 Hz,1500 RPM, AC power supply with power factor 0.8 (lagging), coupled directly to alternator, mounted on a common base plate complete with integral acoustic enclosures (shall have salient features) modular bolted construction & pure polyester based coating to ensure long life in all weather conditions & for outdoor application / installation, integrated design thereby facilitating / easy handling. The design of integral acoustic enclosure shall be approved by National Physical laboratory as per central pollution control board (CPCB-IV +) latest regulation / norms (NOx+HC < 4.0, CO < 3.5, PM < 0.2 & smoke limit < 0.7 ) with fuel tank, battery & standard accessories, tools & spares as provided by manufacturer complete with necessary PCC foundations PCC foundation as per OEM/ manufacturer recommendation to bear the load of DG set having suitable size including excavation and earth work with block masonry work and plastering all as specified and as directed:- | 2 | Each | - | - |
| 3.01 | (I) ENGINE- Efficient CRDI System, designed & tested for 50 degree ambient temperature, Water cooled diesel engine at 1500 RPM, engine capacity suitable for 200 KVA output ,415 V,50 Hz, No of cylinder- 06 Nos consists of direct injection, turbo-charged, four stroke liquid cooled technology confirming to BS : 5514 and IS :10000 suitable for prime duty generating set. Alternator under NTP conditions with provision of 10 % over load for 1 hour confirming to latest CPCB norms .The Engine shall consist of the following:-
(a) Dry type air cleaner
(b) Exhaust silencer
(c) Expansion bellows
(d) Lube oil cooler
(e) Lube oil filter
(f) Radiator, radiator fan and mounting
(g) Fuel pump, with governor
(h) Fly wheel with starter ring
(j) Battery charging alternator with suitable capacity
(k) electric starter motor of suitable Volts as per OEM | - | - | - | - |
| 3.02 | Engine Monitoring system :- The genset monitoring and safety system, having following features :-
(a) Controller Microprocessor based ,Graphical LED display,integrated with AMF,Synchorinisation & Communication compatable , Control panel consisting of built in ON/OFF/start key
(b) Battery charging voltmeter.
(c) Electronic hour meter.
(d) Indication & Monitoring of oil pressure & safety trip in case of Low oil pressure.
(e) Indication & Monitoring of coolant temperature & safety trip in case of high coolant temperature.
(f) In-built engine shut down system in case of engine over speed.
(g) Indication & Monitoring of fuel level and alarm. | - | - | - | - |
| 3.03 | (II) BRUSH LESS ALTERNATOR:- Alternator suitable rated for 200 KVA DG at 0.8 PF, 415V, 3 phase, 4 wire, 50 cycles/sec, 1500 RPM, self excited and self regulated, with Brushless Excitation Band of voltage regulation + 1% of rated voltage, from NO load to full load, Insulation class "H". The alternator generally conforms to BS : 2613/ IS : 4722
(III) BATTERY:- Heavy duty battery of suitable AH and Nos connected to the system fully charged including lead and battery terminals complete of Make as provided by OEM | - | - | - | - |
| 3.04 | (IV) STANDARD CONTROL PANEL
The control panel with aluminium bas bar, bottom entry and exit of cable made of sheet steel duly painted with stove enamel paint consists of followings :-
(a) 01 No MCCB of suitable rating.
(b) 01 No, EMS
(c) 03 Nos Current Transformer
(d) 02 Nos indicating lamps
(e) 01 set control fuses
(f) 01 No KWh meter | - | - | - | - |
| 3.05 | (V) DEF Tank:-
(a) DEF/ Aqueous urea to sets off the chemical reaction with Exhaust gas
(b) Tank size is optimized in accordance to DEF consumption
(VI) Exhaust Gas Treatment System
(a) DOC & SCR system sets off the reaction to meet the
latest CPCB norms
(b) Reduction in NOx & HC ,Reduction in PM
(VII) Supply Module & DCU:- Control & monitor the DEF | - | - | - | - |
| 3.06 | (VIII) AUTOMATIC MAINS FAILURE (AMF) CONTROL PANEL (DOUBLE CONTACTOR)
The control panel will be free standing, , cubical type, outdoor type, front operated dust and vermin proof, fabricated out 3 mm thick CRCA sheet duly power coated after necessary pre-treatment process & consisting of following :-
Power Circuit Mains DG Set
1 No 4P contactor suitable rated
1 No 4P contactor suitable rated
1 No 3P MCCB suitably rated
1 No 3P MCCB suitably rated
Control & Metering Circuit
1 No Microprocessor based AMF logic controller
1 No KWh meter
1 No Line Voltage Monitor L&T Make.
1 set of control fuses
1 No static battery charger circuit with ON/OFF switch. Battery charger "ON" indication. Reserves Polarity indication.
1 No DC battery charging ammeter. | - | - | - | - |
| 3.07 | (IX) ONE SET OF ACCESSORIES COMPRISING OF:-
(a) Fuel tank - Capacity of tank shall be to hold diesel sufficient for 08 hours running at full load, with following features:
(i) Level indicator.
(ii) drain plug .
(iii) MS class 'C' piping for inlet from pump to tank to engine.
(iv) Fuel strainer.
(v) Air vent.
(b) Base plate :- Fabricated out of MS channel's ISMC of suitable size suitable for fixing of DG set all specified by the manufacturer.
(X) Necessary civil foundation works including excavation , PCC , and other requirements as required and as recommended by OEM. The Foundation shall be minimum of 400mm above the FFL. | - | - | - | - |
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
83750TENDERDOCSALL.pdf
Tender Documents • 2.11 MB
BOQ_858588.xls
BOQ • 0.29 MB
83750amdmt1.pdf
PDF • 0.94 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .