Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC NO 390 MARGONADANAHALLI RKM LAYOUT NEAR OCEANUS TRANQUIL APARTMENT KR PURAM BENGALURU 560036 | BENGALURU URBAN | KARNATAKA | 560036 | L1 | Accepted-AOC Accepted Being L1 | |
| 2 | L2₹28.4 L+₹3.3 L (13.3%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹29.4 L+₹4.3 L (17.2%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 |
Tender Value
₹27.3 L
EMD Value
₹54,600
Closing Date
27 May 2023, 6:00 pmClosed
GARRISON ENGINEER CENTRAL BANGALORE
ASC CENTER AND COLLEGE AGRAM POST BANGALORE 560007
ADDITION ALTERATION TO BOUNDARY WALL AT VOC AND SPL REPAIR REPLACEMENT TO OH LINE AT POLO GROUND OF ASC CENTER UNDER GE CENTRAL BANGALORE
2023_MES_593258_1
8282E
Open Tender
Civil Works - Others
Item Rate
150 days
GARRISON ENGINEER CENTRAL BANGALORE
Please refer tender documents
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER CENTRAL BANGALORE
₹54,600
Yes
14 Jul 2023
4 May 2023
29 May 2023
4 May 2023
27 May 2023
15 May 2023
4 May 2023 - 13 May 2023
Amount
Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etcand removal of entire debris as ordered outside MD land complete all as directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15 cm thick above or below ground level and removal of entire debris as ordered outside MD land complete all as directed.
Demolition of brickwork , precast concrrete block walling or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etcand removal of entire debris as ordered outside MD land complete all as directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 cu. m, getting out in soft/ loose soil and removing surplus soil outside MD land complete all as directed.
Excavation in trenches and not exe. 1.5 m wide and not exe. 1.5 m in depth for foundation of drain, man hole , laying of cables , stay etc. not exe. 10 Sq. m on plan and not exe. 1.5 m depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft rock complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 mts and depositing where directed .at a level not exceeding 1.5 M above the starting point complete all as directed.
M & L for PCC 1:3:6, type C2 using 40 mm graded crushed stone aggregate as in foundation filling mass concrete complete all as specified and directed
M&L factory made pre cast PCC 1:3:6, type C1 (using 20 mm graded granite aggregate) as in block masonry with solid blocks, exceeding 10 cm in width and setting in CM 1:6 complete all as specified.
Providing precast ce- ment concrete Type B1 1:2 :4 using 20 mm graded crushed stone aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry),string courses, copings. kneelers, apex stones, pier caps, columns, posts , boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets,etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match Set in cement mortar 1:4 complete all as directed.
Supply only Integral Water Proofing Compound (ISI Marked) of Make : CICO, Acco Proof, Impermo, Aqua flex as approved.
S&F mild steel work in hard rails , winds ties post and structs in fencing screwed or welded to shaped as directed , including all necessary drilling ,bolting or welding etc, and similar work confroming Fe-290 Gde-E-165.
Supply only MS galvanized chain link fencing (120 to 140 gms) 4mm dia and 75mm spacing and weighing not less than 2.75 kg/sqm diagonally pinned including line wire rails, straining bolts and provision of binding wire complete all as specified and as directed. Make : M/s Sachin , TATA or any approved make as approved..
Fixing only diagonally pinned fencing wire including line wire, any mesh size and type of standards, rails, straining bolts etc. including provision of binding wire complete all as directed.
S&F mild steel screw bolts of 11-15 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exceeding 5 cm but not exceeding 10 cm long complete all as specified.
S&F galvanized 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanized mild steel wire, staples or steel pins etc as directed. Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment.
M&L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick work/ stone work or concrete surfaces mixed with WPC as per manufacturer instruction, and finished the surface fair and even complete all as specified and directed. (Note : WPC shall be measured and paid separately).
M&L preparation of newly plastered wall surfaces and applying two coats of cement base paint over a coat of alkali resistant primer complete all as directed.
M & L Two coats of 1st quality synthetic enemal paint over a coat of zinc chromate primer over any description of new steel surface over 10 cm in width or girth including necessary preparation of new steel surface complete all as directed.
Dismantling & taking down old unserviceable aluminium conductor steel reinforced (ACSR) of any size including aluminium binding wire from overhead lines on HT / LT poles complete all as specified and as directed
Dismantling & taking down old unserviceable mild steel cross arms, bracing, supports, clamps, back plates, nuts, bolts, washers, etc of any shape or size from HT / LT poles complete all as directed.
Dismantling & taking down old unserviceable insulators of any type & any size from HT / LT poles complete all as directed
M & L for dry sand cushioning to underground cables in trenches including spreding ,levelling, hand punning and consolidating complete all as specified and directed. Note : Punned thickness shall be considered for measurement purpose
Supply & Laying well klin burnt brick of size 23cmx11.5cmx 8cm , laid breadth wise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and directed.
S&F factory made totally enclosed, shock proof, weather proof, IP-65, dust proof, rust proof, water proof street light pole box with single shutter endorsed in thermo plastic enclosure internally embedded gasket of minimum size 250 x 200 x 105 mm depth with 4 Nos aluminium bus bar with 02 Nos holes of each for receiving cable suitable for 415 volt, 3 phase including MCB SP 6 Amp 240 Volt fixed with suitable MS clamp of flat iron 25x4mm complete all as specified & as directed. Make of box – Hensel/ Syntex Make of MCB :- Legrand (Lexic)/L &T (Hagar)/Siemens (Beta Guard)
M & L for PVC insulated 2 x 2.5 Sqmm multistrand Aluminium conductor for connection of security light to OH or pole box making necessary connection complete all as directed.
Supply, laying, jointing and testing LT XLPE insulated screened PVC, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 10 sqmm 2 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc including necessary fixing arrangements such as lugs & termination etc including testing on completion complete all as directed.
All same as per item No 27 here-in-above but LT XLPE Cable sectional area 16 sqmm 4 core -do-
All same as per item No 27 here-in-above but LT XLPE Cable sectional area 35 sqmm 3.5 core -do-
All same as per item No 27 here-in-above but LT XLPE Cable sectional area 50 sqmm 3.5 core -do-
All same as per item No 27 here-in-above but LT XLPE Cable sectional area 95 sqmm 3.5 core -do- Notes for Item Nos 27 to 31:- (i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions
Supply and fix galvanised iron tubing light grade 50mm bore galvanized with all fitting laid in trenches / road crossing/ across drain / along electric pole etc for UG cable protection all as specified and as directed.
All same as per item No 32 here-in-above but 40 mm bore of pipe -do-
Supply, fabrication, installation and testing of LT out door type factory made(CPRI Approved ), junction box of size 900mm(H)X700mm(B)X400mm(W) (over all dimension ) made out of 3.15mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5 mm frame, 04 Nos aluminium bus bar of of capacity 250 Amps with drilled hole for incoming/outgoing cable connection with necessary alumiium lungs, GI nuts bolts and washer and 160Amp 25KA MCCB 01 No including 08 Nos bridge insulator DMC , heavy duty, suitable for 3 Phase 4 wire system, one danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters, figures and conventional skull & bones in signal red colour and fixed in front door size and PCC (1:3:6) type C-2 foundation 0.30m above normal ground level & 0.30m below ground level with necessary exacavation and earth work and painting to internal and external steel surface with powder coated (Siemence gray) RAL-7032 after neccesary preparation of surfaces including Indicating lamp LED type 240V 50 Hz AC -one set of 3 Make: L&T/Havells/HPL compete all as directed.
M&L for Earthing with & including galvanised mild steel earth plate electrode of size 60 cm x 60 cm x 6 mm thick buried vertically in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the earth plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to & including galvanized iron earth strip 32x6 mm as earth lead, including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted to earth plate at one end and other end of earth wire connected to transformer / GOD / Panel / pump set / equipment body / test point, GI earth wire encased in and including 20 mm bore GI medium grade pipe with all fittings from upper edges of earth plate upto 7.5 metre above ground level fixed with and including 25x3mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 32mm bore GI pipe medium grade from earth pit to top of electrode and including funnel, wire mesh, copper lugs etc complete with earth pit in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and 40mm thick RCC (1:2:4 type B1) cover complete all as specified and shown in electrical plate No 3 of SSR Part-I including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance not exc 50m complete all as specified and as directed. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.
Chandana Enterprises
kamadhenu Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .