9 Sept 2026, 11:00 am
Shilpa P K
POWER GRID CORPORATION OF INDIA Ltd, SRTS II, Near RTO Driving Test Track, Singanayakanahalli, Yelahanka Hobli. BANGALORE 560064
Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
SR2/NT/W-AIS/DOM/C00/26/10293
Open
Construction Works
Works
Pugalur HVAC SS and Tirunelveli SS
₹25,000
7 Aug 2026
7 Aug 2026
9 Sept 2026
7 Aug 2026
7 Sept 2026
7 Aug 2026
26 Aug 2026
Package Name WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
Package Code SubStation
Specification No. SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546)
I While filling up the worksheets following may please be observed :
(i) Fill up only green shaded cells.
(ii) Certain data type entries have been restricted, such as Numeric values or limits of numeric values.
(iii) Select only the options provided in pull down menus.
(iv) Do not link any cell of this work book with any other work book.
(v) Do not use copy & paste or cut & paste options for filling up the data.
(vi) Do not reformat any of the cell of the work book.
II This Workbook consists of following worksheets :
Opening page of the workbook.
Names of Bidder :
● Select Bidder from the pull down menu. Do not leave this cell blank.
● Select nos. of the JV Partners other than the Lead Partner from drop down menu.
● In case of JV partners more than 2, enter details of 3rd & more partners along with details of 2nd partner.
● Fill up names and address of the Bidder and /or Joint Venture.
● Fill up date in dd-mmm-yyyy format from drop down menu.
● Click for Sch-1 given at the right top of the worksheet to go to Sch-1.
Sch-1 (Ex-works Prices) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Corresponding cell for mode of transaction shall be come enable only after filling up the unit rate, therefore first fill up the unit rate and then mode of transaction for the corresponding item.
● Total amount shall get calculated automatically.
● Type Test charges shall appear automatically after filling up Sch-7 appropriately.
Sch-2 (Freight & Insurance Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-3 (Erection Charges) :
● Fill up unit rates for all the items in numeric values greater than 0 (zero). If unit rate is left blank, the corresponding item shall be deemed to be included in the total price.
● Total amount shall get calculated automatically.
Sch-4 (Training Charges) :
● Not applicable, hence no cell is required to be filled up.
Sch-5 (Summary of Taxes and Duties applicable on the Services) :
● No cell is required to be filled in by the bidder in this worksheet.
● Summary of all the Schedules without considering discount (mentioned in the work sheet discount) shall be displayed automatically.
● No cell is required to be filled in by the bidder in this worksheet.
Sch-7 (Type Test Charges) :
● Fill up the rates & location where type tests are proposed.
● Total of this Sch-7 shall automatically appear in Sch-1.
Bid from 2nd Envelope :
● Fill up ref. no. as bidder's ref no. of this letter.
● This letter shall consider the net price as per Sch-6 (After Discount).
● Fill up names & Designation of the representatives of other JV partner(s) if the bidder is JV (Joint Venture) .
● Fill up additional information as required.
Happy Bidding !
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546)
1 Fill up only green shaded cells in Sch-1, Sch-2, Sch-3 and Bid Form 2nd Envelope.
2 All the cells in Sch-5 & Sch-6 are auto filled, therefore no cell is required to be filled up there.
3 Instructions / error messages, if any, will be displayed automatically after selecting the cell.
4 After filling up all the schedues, save the file, take print out of all the schedules and Bid form and sign & stamp and submit them as hard copy of the 2nd envelope (Price part) of the bid. Also ensure to submit the soft copy of the the same file on CD/ DVD.
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546) Sole Bidder
Enter following details of the bidder
Specify type of Bidder [Select from drop down menu] Others 2
Name of Lead Partner
Address of Lead Partner
Name of other Partner - 1
Address of other Partner - 1
Name of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
Address of other Partner - 2 (more, if any) …….. …….. …….. …….. …….. ……..
email ID of Bid Signatory
Mobile No. of Bid Signatory
Tel No. of Bid Signatory
Fax No. of Bid Signatory
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546) Schedule - 1
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(SCHEDULE OF RATES AND PRICES)
Bidder’s Name and Address (Lead Partner) : To:
Sr.General Manager,
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore -560064
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted
All Prices are in Indian Rupees.
SI. No. HSN Code Whether HSN in column ‘ 2’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘ 4 ’ is confirmed. If not indicate applicable rate of GST * Item Description Unit Qty. Unit Ex-works price (excluding GST) Total Ex-works price (excluding GST) GST TAX as confirmed by Bidder
I SubStation Revaluation of J column Tax Calculation
Part A - Indoor components of LT System
1 222222 18% confirmed 415V AC Main Switch Board as per the TS enclosed. Set 1 Included 0.00 0 0.00
2 2 18% 415V ACDB- I as per the TS enlosed. Set 1 Included 0.00 0 0.00
3 2 18% 415V ACDB- II as per the TS enclosed Set 1 Included 0.00 0 0.00
4 2 18% 415V AC Main Lighting Distribution Board including two nos 100KVA rated lighting transformers as per the TS enclosed Set 1 Included 0.00 0 0.00
5 2 18% 415V AC Emergency Lighting Distribution Board including one no 100KVA rated lighting transformers. Set 1 Included 0.00 0 0.00
6 2 18% 415V AC Emergency Diesel Switchgear Set 1 Included 0.00 0 0.00
7 2 18% 415V ACDB for colony lighting Set 2 Included 0.00 0 0.00
8 2 18% 415V Air conditioning DB Set 1 Included 0.00 0 0.00
9 2 18% 48V DCDB Nos 2 Included 0.00 0 0.00
10 2 18% 220V DCDB Nos 2 Included 0.00 0 0.00
11 2 18% Mandatory Spares as per the BOM in Vol-II Lot 1 Included 0.00 0 0.00
Part B - Out door components of LT system 0 0.00
1 1 18% 630KVA, 22kV/433V, DYn1 LT transformer Nos 2 Included 0.00 0 0.00
2 1 18% 33kV, 200A, Horn Gap fuse(1Ph) as per the TS enclosed. Nos. 6 Included 0.00 0 0.00
3 1 18% 33KV, 630A, 3Ph, 25KA/3sec, manual operated HDB electrically ganged Isolator without earth switch as per the TS enclosed. Nos. 2 Included 0.00 0 0.00
4 1 18% 22KV/433V Potential transformer (1Ph) as per the TS enclosed. Nos. 6 Included 0.00 0 0.00
5 1 18% 18KV, 10KA , Class-III Surge arrestors as per TS enclosed. Nos. 6 Included 0.00 0 0.00
6 1 18% 33KV Post insulators Nos. 24 Included 0.00 0 0.00
7 1 18% H-Pole structure for 22KV sytem as per the indicative drawing enclosed, Set 2 Included 0.00 0 0.00
8 1 18% Conductor, Clamps,Connector including equipment connectors earthing materials for 22KV system equipments including LT transformer neutral earthing, risers, Lighting spike, GI flats for earthing the structures, Equipments etc for connection of LT transformer and other 22KV equipments Set 2 Included 0.00 0 0.00
9 1 18% 1CX630Sq.mm AL.XLPE cable along with clamps, Glands and straight Joints Km 1.4 Included 0.00 0 0.00
10 Mandatory spares for LT transformer 0 0.00
a 1 18% All Bushings with metal parts Set 1 Included 0.00 0 0.00
b 1 18% OTI with sensing device Set 1 Included 0.00 0 0.00
c 1 18% Set of valves (o1 no. each type) Set 1 Included 0.00 0 0.00
d 1 18% Silica Gel container Set 1 Included 0.00 0 0.00
e 1 18% Bucholz relay Set 1 Included 0.00 0 0.00
11 1 18% Mandatory spares for 22KV equipments as per the BOM attached Lot 1 Included 0.00 0 0.00
Total Ex-Works Price Excluding GST 0.00 Total Tax
Total Type Test charges as per Schedule-7 0.00
Total Ex-works Price including Type Test charges 0.00
Total GST Tax as confirmed by Bidder 0.00
Note : Specify amount of GST on the transaction between the Contractor and the Employer.
* In case the bidder leaves the cell for confirmation of the HSN code and/or GST rate “blank”, the HSN code and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Place : Printed Name :
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546) Schedule - 1 Direct Total 0 Others `
BO Total #REF! 0
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(SCHEDULE OF RATES AND PRICES : EX-WORKS PRICES)
Bidder’s Name and Address (Lead Partner) : To:
Contract Services
Name : Power Grid Corporation of India Ltd., , & …….. …….. …….. …….. …….. ……..
Address : "Saudamini", Plot No.-2
Gurgaon (Haryana) - 122001
Plant and Equipment (including Mandatory Spares Parts) to be supplied, including Type Test Charges for Tests to be conducted. Direct
All Prices are in Indian Rupees. Bought-Out
SI. No. Item Description Unit Qty. Unit Ex-works price Total Ex-works price Mode of Transaction (Direct / Bought-out)
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total Ex-Works Price Direct 0.00 Direct
Total Ex-Works Price Bought Out 0.00
Total Ex-Works Price 0.00
Total Type Test charges as per Schedule-7 #REF! #REF! #REF!
Total Ex-works Price including Type Test charges #REF! #REF! #REF!
Discount Sch-1 #REF! MPD Sch-1 #REF!
Dis Alert #REF!
Note : Specify amount of Excise Duty, Sales Tax/'VAT and other taxes payable on the transaction between the Contractor and the Employer and octroi/entry tax as applicable for destination site/state on all items of supply including bought-out finished items (to be identified in the Contract), which shall be dispatched directly from the sub-vendor’s works to the Employer’s site (sale-in-transit), separately in Schedule-5. Excise Duty, Sales tax and other levies for all the bought-out items are to be included in the EXW Price (Col. No. 5) only and not to be indicated in Schedule-5.
Place : Printed Name :
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546) Schedule - 1
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES )- EX-WORKS PRICES AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-3 #REF!
Sr.General Manager,
C&M Department Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka Multipackage lum-sum #REF!
Bangalore -560064
Ex-works price of Plant and Equipment
All Prices are in Indian Rupees.
SI. No. Line item no. HSN (Harmonized System of Nomenclature) Whether HSN/ SAC in column '2’ is confirmed. If not, indicate applicable HSN/SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘ 4 ’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Rate in Rs. Total in Rs. GST TAX as confirmed by Bidder Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
A Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
1 10 73082011 18% confirmed Fabrication, galvanising and supply of Equipment Support (Pipe)Structures to be designed during detailed engineering MT 24 Included 0.00 0 0
2 20 73082011 18% confirmed Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 1 Included 0.00 0 0
3 30 73082011 18% confirmed Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 2 Included 0.00 0 0
4 40 85352913 18% confirmed 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without closing resistorand with Support Structure EA 2 Included 0.00 0 0
5 50 85353090 18% confirmed 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 14 Included 0.00 0 0
6 60 85359090 18% confirmed 420 kV, 3000A, 63KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 18 Included 0.00 0 0
7 70 85354010 18% confirmed 336kV Surge Arrester (1-phase) EA 6 Included 0.00 0 0
8 80 85462040 18% confirmed 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 9 Included 0.00 0 0
9 90 85352913 18% confirmed 420kV, 3150A, 63KA Circuit Breaker (3-Phase) with closing resistor with support structure EA 4 Included 0.00 0 0
10 100 72169990 18% confirmed Erection Hardware for 400kV I type layout-Line bay as per technicalspecification SET 2 Included 0.00 0 0
11 110 72169990 18% confirmed Erection Hardware for 400kV I type layout-Spare bay of half dia as pertechnical specification SET 2 Included 0.00 0 0
12 120 85176210 18% confirmed 400kV,3150A,0.5mH ,63kA Line Trap EA 2 Included 0.00 0 0
13 130 85462040 18% confirmed 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included 0.00 0 0
14 140 85176210 18% confirmed Digital Protection Coupler EA 2 Included 0.00 0 0
15 150 85176210 18% confirmed 400kV, 3150A, 63kA, 1mH Line Trap EA 2 Included 0.00 0 0
16 160 85446020 18% confirmed 1.1kV grade Power Cables (PVCinsulated) incl. lugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 0
17 170 85446020 18% confirmed 1.1kV grade Control Cables (PVCinsulated) incl. lugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 0
18 180 85359090 18% confirmed Spares CB as per Annexure Spares LS 1 Included 0.00 0 0
19 190 85353090 18% confirmed Spares Isolator as per Annexure spares LS 1 Included 0.00 0 0
20 200 85389000 18% confirmed Spare CT LS 1 Included 0.00 0 0
21 210 85354010 18% confirmed Spares LA as per annexure Spares LS 1 Included 0.00 0 0
22 220 85176210 18% confirmed Spares PLCC annexure Spares LS 1 Included 0.00 0 0
23 230 85354010 18% confirmed Spares communication system as per annexure spares LS 1 Included 0.00 0 0
24 240 85176290 18% confirmed Equipment Cabinets For SDH EA 1 Included 0.00 0 0
25 250 85176260 18% confirmed SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included 0.00 0 0
26 260 85176290 18% confirmed OPTICAL INTERFACE/SFP-V16.2 EA 4 Included 0.00 0 0
27 270 85176290 18% confirmed Optical Line Interface card To support minimum 175 km EA 2 Included 0.00 0 0
28 280 85176290 18% confirmed OPTICAL INTERFACE CARD (TO SUPPORT MINIMUM 225 KMS) FOR STM-16 EA 2 Included 0.00 0 0
29 290 85176290 18% confirmed TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 Included 0.00 0 0
30 300 85176990 18% confirmed ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 Included 0.00 0 0
31 310 85176290 18% confirmed TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included 0.00 0 0
32 320 85176290 18% confirmed Equipment Cabinets For SDH EA 1 Included 0.00 0 0
33 330 85372000 18% confirmed 192 FIBRE FODP : INDOOR TYPE, RACK MOUNTED WITH FCPC COUPLING & PIGTAILS(5MTRS) EA 1 Included 0.00 0 0
34 340 85447090 18% confirmed 96F (DWSM) APPROACH FIBRE OPTIC CABLE KM 0.5 Included 0.00 0 0
35 350 73069011 18% confirmed GI PIPE INSTALLATION HARDWARE FOR APPROACH CABLING KM 0.5 Included 0.00 0 0
36 360 73071900 18% confirmed GI ELBOW INSTALLATION HARDWARE FOR APPROAH CABLING EA 5 Included 0.00 0 0
37 370 83071000 18% confirmed GI FLEXIBLE CONDUIT INSTALLATION HARDWARE FOR APPROAH CABLING EA 4 Included 0.00 0 0
B Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor
38 380 73082011 18% confirmed Fabrication, galvanising and supply of Equipment Support (Pipe)Structures to be designed during detailed engineering MT 24 Included 0.00 0 0
39 390 73082011 18% confirmed Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 1 Included 0.00 0 0
40 400 73082011 18% confirmed Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 2 Included 0.00 0 0
41 410 85352913 18% confirmed 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without closing resistorand with Support Structure EA 6 Included 0.00 0 0
42 420 85353090 18% confirmed 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 12 Included 0.00 0 0
43 430 85359090 18% confirmed 420 kV, 3000A, 63KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 18 Included 0.00 0 0
44 440 85354010 18% confirmed 336kV Surge Arrester (1-phase) EA 6 Included 0.00 0 0
45 450 85462040 18% confirmed 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 9 Included 0.00 0 0
46 460 85353090 18% confirmed 420kV, 3150A, 63KA Isolator (3-phase)(Double Break) with two E/S EA 2 Included 0.00 0 0
47 470 72169990 18% confirmed Erection Hardware for 400kV I type layout-Line bay as per technicalspecification SET 2 Included 0.00 0 0
48 480 72169990 18% confirmed Erection Hardware for 400kV I type layout-Spare bay of half dia as pertechnical specification SET 2 Included 0.00 0 0
49 490 85176210 18% confirmed 400kV,3150A,0.5mH ,63kA Line Trap EA 4 Included 0.00 0 0
50 500 85462040 18% confirmed 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included 0.00 0 0
51 510 85176210 18% confirmed Digital Protection Coupler EA 2 Included 0.00 0 0
52 520 85446020 18% confirmed 1.1kV grade Power Cables (PVCinsulated) incl. lugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 0
53 530 85446020 18% confirmed 1.1kV grade Control Cables (PVCinsulated) incl. lugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 0
54 540 85359090 18% confirmed Spares CB as per Annexure Spares LS 1 Included 0.00 0 0
55 550 85353090 18% confirmed Spares Isolator as per Annexure spares LS 1 Included 0.00 0 0
56 560 85389000 18% confirmed Spare CT LS 1 Included 0.00 0 0
57 570 85354010 18% confirmed Spares LA as per annexure Spares LS 1 Included 0.00 0 0
58 580 85176210 18% confirmed Spares PLCC annexure Spares LS 1 Included 0.00 0 0
59 590 85176260 18% confirmed SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included 0.00 0 0
60 600 85176990 18% confirmed S16.1 SFP EA 4 Included 0.00 0 0
61 610 85176290 18% confirmed Optical Line Interface card (to support minimum 150 kms) EA 2 Included 0.00 0 0
62 620 85176290 18% confirmed TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 Included 0.00 0 0
63 630 85176990 18% confirmed ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 Included 0.00 0 0
64 640 85176290 18% confirmed TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included 0.00 0 0
65 650 85176290 18% confirmed Equipment Cabinets For SDH EA 1 Included 0.00 0 0
GST Amount 0.00
* In case the bidder leaves the cell for confirmation of the SAC and/or GST rate “blank”, the SAC and corresponding GST rate indicated by the Employer shall be deemed to be the one confirmed by the Bidder.
Place : Printed Name :
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546) Schedule - 2
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(SCHEDULE OF RATES AND PRICES)- FREIGHT & INSURANCE CHARGES
Bidder’s Name and Address (Lead Partner) : To:
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore -560064
Local Transportation, Insurance and other Incidental Services
All Prices are in Indian Rupees.
SI. No. HSN Code Whether HSN in column ‘2’ is confirmed. If not indicate applicable the HSN code * Rate of GST applicable ( in %) Whether rate of GST in column ‘4’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Freight, Insurance, loading & unloading Charges (including GST, if any) Total Freight, Insurance, loading & unloading Charges (including GST, if any)
A Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
1 1 1 1 1 Fabrication, galvanising and supply of Equipment Support (Pipe)Structures to be designed during detailed engineering MT 24 Included
2 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 1 Included
3 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 2 Included
4 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without closing resistorand with Support Structure EA 2 Included
5 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 14 Included
6 420 kV, 3000A, 63KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 18 Included
7 336kV Surge Arrester (1-phase) EA 6 Included
8 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 9 Included
9 420kV, 3150A, 63KA Circuit Breaker (3-Phase) with closing resistor with support structure EA 4 Included
10 Erection Hardware for 400kV I type layout-Line bay as per technicalspecification SET 2 Included
11 Erection Hardware for 400kV I type layout-Spare bay of half dia as pertechnical specification SET 2 Included
12 400kV,3150A,0.5mH ,63kA Line Trap EA 2 Included
13 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included
14 Digital Protection Coupler EA 2 Included
15 400kV, 3150A, 63kA, 1mH Line Trap EA 2 Included
16 1.1kV grade Power Cables (PVCinsulated) incl. lugs,glands,straight joints &accessories,etc. LS 1 Included
17 1.1kV grade Control Cables (PVCinsulated) incl. lugs,glands,straight joints &accessories,etc. LS 1 Included
18 Spares CB as per Annexure Spares LS 1 Included
19 Spares Isolator as per Annexure spares LS 1 Included
20 Spare CT LS 1 Included
21 Spares LA as per annexure Spares LS 1 Included
22 Spares PLCC annexure Spares LS 1 Included
23 Spares communication system as per annexure spares LS 1 Included
24 Equipment Cabinets For SDH EA 1 Included
25 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included
26 OPTICAL INTERFACE/SFP-V16.2 EA 4 Included
27 Optical Line Interface card To support minimum 175 km EA 2 Included
28 OPTICAL INTERFACE CARD (TO SUPPORT MINIMUM 225 KMS) FOR STM-16 EA 2 Included
29 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 Included
30 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 Included
31 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included
32 Equipment Cabinets For SDH EA 1 Included
33 192 FIBRE FODP : INDOOR TYPE, RACK MOUNTED WITH FCPC COUPLING & PIGTAILS(5MTRS) EA 1 Included
34 96F (DWSM) APPROACH FIBRE OPTIC CABLE KM 0.5 Included
35 GI PIPE INSTALLATION HARDWARE FOR APPROACH CABLING KM 0.5 Included
36 GI ELBOW INSTALLATION HARDWARE FOR APPROAH CABLING EA 5 Included
37 GI FLEXIBLE CONDUIT INSTALLATION HARDWARE FOR APPROAH CABLING EA 4 Included
Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor Included
38 Fabrication, galvanising and supply of Equipment Support (Pipe)Structures to be designed during detailed engineering MT 24 Included
39 Fabrication, galvanising and supply of fasteners ( nuts, bolts andwashers ) including step bolts for lattice and pipe structures to bedesigned during detailed engineering MT 1 Included
40 Fabrication, galvanising and supply of foundation bolts including nuts,checknut and washers for lattice and pipe structures to be designedduring detailed engineering MT 2 Included
41 420kV, 3150A, 63kA Circuit Breaker (3-Phase) without closing resistorand with Support Structure EA 6 Included
42 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 12 Included
43 420 kV, 3000A, 63KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 18 Included
44 336kV Surge Arrester (1-phase) EA 6 Included
45 420 kV, 1 phase Bus Post Insulator (except for Line Traps) EA 9 Included
46 420kV, 3150A, 63KA Isolator (3-phase)(Double Break) with two E/S EA 2 Included
47 Erection Hardware for 400kV I type layout-Line bay as per technicalspecification SET 2 Included
48 Erection Hardware for 400kV I type layout-Spare bay of half dia as pertechnical specification SET 2 Included
49 400kV,3150A,0.5mH ,63kA Line Trap EA 4 Included
50 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included
51 Digital Protection Coupler EA 2 Included
52 1.1kV grade Power Cables (PVCinsulated) incl. lugs,glands,straight joints &accessories,etc. LS 1 Included
53 1.1kV grade Control Cables (PVCinsulated) incl. lugs,glands,straight joints &accessories,etc. LS 1 Included
54 Spares CB as per Annexure Spares LS 1 Included
55 Spares Isolator as per Annexure spares LS 1 Included
56 Spare CT LS 1 Included
57 Spares LA as per annexure Spares LS 1 Included
58 Spares PLCC annexure Spares LS 1 Included
59 SDH EQUIPMENT (STM-16 MADM UPTO 5 MSP PROTECTED DIRECTIONS)-BASEEQUIPMENT (COMMON CARDS, CROSS CONNECT/CONTROL CARDS, OPTICAL BASECARDS, POWER SUPPLY CARDS, POWER CABLING, OTHER HARDWARE ANDACCESSORIES INCLUDING SUB RACKS, PATCH CORD, DDF ETC FULLY EQUIPEDEXCLUDING OPTICAL INTERFACE & TRIBUTARY CARDS EA 1 Included
60 S16.1 SFP EA 4 Included
61 Optical Line Interface card (to support minimum 150 kms) EA 2 Included
62 TRIBUTARY INTERFACE- E1 INTERFACE (MINIMUM 16 NOS.) SET 2 Included
63 ETHERNET INTERFACE 10/100 BASE T WITH LAYER-2 SWITCHING (MIN 8INTERFACES PER CARD) EA 2 Included
64 TRIBUTARY INTERFACE-GIGABIT ETHERNET INTERFACES 10/100 MBPS WITH LAYER-2 SWITCHING (MINIMUM 2 NOS.) SET 1 Included
65 Equipment Cabinets For SDH EA 1 Included
Total F&I Price (including GST, if any) 0.00
Place : Printed Name :
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546) Schedule - 2 Dis
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor. As per Lum-sum 0
(SCHEDULE OF RATES AND PRICES : FREIGHT & INSURANCE CHARGES) AS per Percent #REF!
As per lum-sum on Sch-2 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-2 #REF!
C&M Department Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka Multipackage Discount #REF!
Bangalore -560064
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. Description Unit Quantity Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges Unit Freight & Insurance Charges Total Freight & Insurance Charges
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
#REF! #REF! #REF! #REF! #REF! #REF!
Total F&I Price #REF!
Place : Printed Name :
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546)
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : ERECTION CHARGES) AS per Percent #REF!
As per lum-sum on Sch-3 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-3 #REF!
C&M Department Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka Multipackage lum-sum #REF!
Bangalore -560064
Total Installation/Service Charges
All Prices are in Indian Rupees. Amount after Discount (Rs.) Dis Alert Amount after MPD (Rs.)
SI. No. SAC (Service Accounting Codes) DSR/Service code Whether SAC in column '2’ is confirmed. If not, indicate applicable SAC * Rate of GST applicable ( in %) Whether rate of GST in column ‘ 4 ’ is confirmed. If not indicate applicable rate of GST * Description Unit Quantity Unit Erection Charges Total Erection Charges GST TAX as confirmed by Bidder `` Unit Erection Charges Total Erection Charges Unit Erection Charges Total Erection Charges
1 2 3 4 4 6 7 8 9 10 11=9*10 Revaluation of J column Tax Calculation 5 6 = 4 x 5 5 6 = 4 x 5
A Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
1 995455 100001241 18% confirmed Erection of Equipment Support (Pipe) Structures to be designed during detailed engineering. MT 24 Included 0.00 0 0
2 995455 100001680 18% confirmed Erection of fasteners ( nuts, bolts and washers ) including step bolts for lattice and pipe structures to be designed duringdetailed engineering MT 1 Included 0.00 0 0
3 995455 100001681 18% confirmed Erection of foundation bolts including nuts, checknut and washers for lattice and pipe structures to be designed during detailedengineering MT 2 Included 0.00 0 0
4 995459 100003810 18% confirmed Dismantling of equipment incl. Lattice/Pipe Support Structure : 400kV BPI (1-Phase) EA 9 Included 0.00 0 0
5 995459 100003811 18% confirmed Dismantling of equipment incl. Lattice/Pipe Support Structure : 400kV WT(3 No. BPI) EA 4 Included 0.00 0 0
6 995459 100003822 18% confirmed Dismantling of equipment incl. Lattice/Pipe Support Structure: 400kV Circuit Breaker (3-Phase) EA 6 Included 0.00 0 0
7 995459 100003807 18% confirmed Dismantling of equipment incl. Lattice/Pipe Support Structure : 400kV Isolator with one E/s (3-Phase) EA 14 Included 0.00 0 0
8 995459 100003806 18% confirmed Dismantling of equipment incl. Lattice/Pipe Support Structure : 400kV CT (1-Phase) EA 21 Included 0.00 0 0
9 995459 100003809 18% confirmed Dismantling of equipment incl. Lattice/Pipe Support Structure : 400kV SA (1-Phase) EA 6 Included 0.00 0 0
10 998736 100000267 18% confirmed Installation : 420kV, 3150A, 63kA Circuit Breaker(3-Phase) without closing resistor(with support structure) EA 2 Included 0.00 0 0
11 998736 100000287 18% confirmed Installation : 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 14 Included 0.00 0 0
12 998736 100000274 18% confirmed Installation : 420 kV, 3000A, 63KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 18 Included 0.00 0 0
13 998736 100000328 18% confirmed Installation : 336kV Surge Arrester (1-phase) EA 6 Included 0.00 0 0
14 998736 100000340 18% confirmed Installation : 420 kV Bus Post Insulator (Except for wave traps) EA 9 Included 0.00 0 0
15 998736 100000266 18% confirmed Installation : 420kV, 3150A, 63KA Circuit Breaker(3-Phase) with closing resistor(withsupport structure) EA 4 Included 0.00 0 0
16 998731 100000329 18% confirmed Installation : Erection Hardware for 400kV I type layout-Line bay as per specification SET 2 Included 0.00 0 0
17 998731 100000335 18% confirmed Installation : Erection Hardware for 400kV I type layout-Spare bay of half dia as per specification SET 2 Included 0.00 0 0
18 998734 100002042 18% confirmed 400kV,3150A,0.5mH ,63kA Line Trap EA 2 Included 0.00 0 0
19 998734 100000883 18% confirmed 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included 0.00 0 0
20 998734 100000891 18% confirmed Digital Protection Coupler EA 2 Included 0.00 0 0
21 998734 100002041 18% confirmed 400kV,3150A,1.0mH ,63kA Line Trap EA 2 Included 0.00 0 0
22 998736 18% confirmed 1.1kV grade Power Cables (PVCinsulated) incl. lugs,glands,straight joints &accessories,etc. LOT 1 Included 0.00 0 0
23 998736 18% confirmed 1.1kV grade Control Cables (PVCinsulated) incl. lugs,glands,straight joints &accessories,etc. LOT 1 Included 0.00 0 0
24 998734 100002812 18% confirmed SDH Equipment (STM-16 MADM upto 5 MSP protected directions)-Base Equipment (Common cards, Cross Connect/control cards, optical basecards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc fully equipedexcluding optical interface & Tributary cards EA 1 Included 0.00 0 0
25 998734 170000433 18% confirmed Optical Interface Cards/SFP# -S16.1 for SDH Equipment-STM-16 EA 4 Included 0.00 0 0
26 998734 100003449 18% confirmed Optical Interface Card (to support minimum 175 kms) for STM-16 EA 2 Included 0.00 0 0
27 998734 100002825 18% confirmed Tributary interface- E1 interface (Minimum 16 nos.) SET 2 Included 0.00 0 0
28 998336 170000550 18% confirmed Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 2 Included 0.00 0 0
29 998734 100002829 18% confirmed Tributary interface-Gigabit Ethernet Interfaces 10/100 Mbps with Layer -2 Switching (minimum 2 nos.) SET 1 Included 0.00 0 0
30 998734 170000375 18% confirmed Equipment Cabinets-For SDH Equipments EA 1 Included 0.00 0 0
31 998734 100002812 18% confirmed SDH Equipment (STM-16 MADM upto 5 MSP protected directions)-Base Equipment (Common cards, Cross Connect/control cards, optical basecards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc fully equipedexcluding optical interface & Tributary cards EA 1 Included 0.00 0 0
32 998734 100002813 18% confirmed Optical Interface/SFP-V16.2 EA 4 Included 0.00 0 0
33 998734 100003449 18% confirmed Optical Interface Card (to support minimum 175 kms) for STM-16 EA 2 Included 0.00 0 0
34 998734 100002822 18% confirmed Optical Interface Card (to support minimum 225 kms) for STM-16 EA 2 Included 0.00 0 0
35 998734 100002825 18% confirmed Tributary interface- E1 interface (Minimum 16 nos.) SET 2 Included 0.00 0 0
36 998336 170000550 18% confirmed Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 2 Included 0.00 0 0
37 998734 100002829 18% confirmed Tributary interface-Gigabit Ethernet Interfaces 10/100 Mbps with Layer -2 Switching (minimum 2 nos.) SET 1 Included 0.00 0 0
38 998734 170000375 18% confirmed Equipment Cabinets-For SDH Equipments EA 1 Included 0.00 0 0
39 998336 170000500 18% confirmed 8Port VOIP Gateway EA 1 Included 0.00 0 0
40 998336 170005265 18% confirmed Installation of 192 Fibre FODP : Indoor Type, Rack Mounted with FCPC Coupling & Pigtails (5mtrs) EA 1 Included 0.00 0 0
41 998336 170005260 18% confirmed Fibre Optic Approach cabling: Including installation hardware like GI pipe, elbow, conduits, accessories etc.: 96 Fibre KM 0.5 Included 0.00 0 0
B Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor Included 0.00 0 0
42 995455 100001241 18% confirmed Erection of Equipment Support (Pipe) Structures to be designed during detailed engineering. MT 24 Included 0.00 0 0
43 995455 100001680 18% confirmed Erection of fasteners ( nuts, bolts and washers ) including step bolts for lattice and pipe structures to be designed duringdetailed engineering MT 1 Included 0.00 0 0
44 995433 100001681 18% confirmed Erection of foundation bolts including nuts, checknut and washers for lattice and pipe structures to be designed during detailedengineering MT 2 Included 0.00 0 0
45 995459 100003810 18% confirmed Dismantling of eqpt incl. Lattice/Pipe Support Structure : 400kV BPI (1-Phase) EA 9 Included 0.00 0 0
46 995459 100003811 18% confirmed Dismantling of eqpt incl. Lattice/Pipe Support Structure : 400kV WT(3 No. BPI) EA 4 Included 0.00 0 0
47 995459 100003822 18% confirmed Dismantling of eqpt incl. Lattice/Pipe Support Structure : 400kV Circuit Breaker (3-Phase) EA 6 Included 0.00 0 0
48 995459 100003807 18% confirmed Dismantling of eqpt incl. Lattice/Pipe Support Structure : 400kV Isolator (3-Phase) ( 12 no's single ES and 2 no's double ES isolator ) EA 14 Included 0.00 0 0
49 995459 100003806 18% confirmed Dismantling of eqpt incl. Lattice/Pipe Support Structure : 400kV CT (1-Phase) EA 18 Included 0.00 0 0
50 995459 100003809 18% confirmed Dismantling of eqpt incl. Lattice/Pipe Support Structure : 400kV SA (1-Phase) EA 6 Included 0.00 0 0
51 998736 100000267 18% confirmed Installation : 420kV, 3150A, 63kA Circuit Breaker(3-Phase) without closing resistor(with support structure) EA 6 Included 0.00 0 0
52 998736 100000287 18% confirmed Installation : 420kV, 3150A, 63KA, Isolator (3-phase)(Double Break) with one E/S EA 12 Included 0.00 0 0
53 998736 100000274 18% confirmed Installation : 420 kV, 3000A, 63KA, 1-Phase CurrentTransformer with 120% extended currentrating EA 18 Included 0.00 0 0
54 998736 100000328 18% confirmed Installation : 336kV Surge Arrester (1-phase) EA 6 Included 0.00 0 0
55 998736 100000340 18% confirmed Installation : 420 kV Bus Post Insulator (Except for wave traps) EA 9 Included 0.00 0 0
56 998736 100000288 18% confirmed Installation : 420kV, 3150A, 63KA Isolator (3-phase)(Double Break) with two E/S EA 2 Included 0.00 0 0
57 998731 100000329 18% confirmed Erection Hardware for 400kV I type layout-Line bay as per specification SET 2 Included 0.00 0 0
58 998731 100000335 18% confirmed Erection Hardware for 400kV I type layout-Spare bay of half dia as per specification SET 2 Included 0.00 0 0
59 998734 100002042 18% confirmed 400kV,3150A,0.5mH ,63kA Line Trap EA 4 Included 0.00 0 0
60 998734 100000883 18% confirmed 420 kV ,1 phase Bus Post Insulators for Line Traps EA 12 Included 0.00 0 0
61 998734 100000891 18% confirmed Digital Protection Coupler EA 2 Included 0.00 0 0
62 998736 100002920 18% confirmed 1.1kV grade Power Cables (PVCinsulated) incl. lugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 0
63 998736 100002977 18% confirmed 1.1kV grade Control Cables (PVCinsulated) incl. lugs,glands,straight joints &accessories,etc. LS 1 Included 0.00 0 0
64 998734 100002812 18% confirmed SDH Equipment (STM-16 MADM upto 5 MSP protected directions)-Base Equipment (Common cards, Cross Connect/control cards, optical basecards, power supply cards, power cabling, other hardware and accessories including sub racks, patch cord, DDF etc fully equipedexcluding optical interface & Tributary cards EA 1 Included 0.00 0 0
65 998734 170000433 18% confirmed Optical Interface Cards/SFP# -S16.1 for SDH Equipment-STM-16 EA 4 Included 0.00 0 0
66 998734 170000374 18% confirmed Optical Interface Card (to support minimum 150 kms) for STM-16 EA 2 Included 0.00 0 0
67 998734 100002825 18% confirmed Tributary interface- E1 interface (Minimum 16 nos.) SET 2 Included 0.00 0 0
68 998336 170000550 18% confirmed Ethernet Interface 10/100 Base T with Layer-2 switching (Min 8 Interfaces per card) EA 2 Included 0.00 0 0
69 998734 100002829 18% confirmed Tributary interface-Gigabit Ethernet Interfaces 10/100 Mbps with Layer -2 Switching (minimum 2 nos.) SET 1 Included 0.00 0 0
70 998734 170000375 18% confirmed Equipment Cabinets-For SDH Equipments EA 1 Included 0.00 0 0
C Civil works at Tirunelveli Station -Reconductoring of Tirunelveli -Udumalpet and Pugalur – Madurai 400kV D/c lines with HTLS conductor 0.18 confirmed Included 0.00 0 0
71 995433 1.1.1 18% confirmed CARRIAGE OF MATERIALS: BY MECHANICAL TRANSPORT INCLUDING LOADING,UNLOADING AND STACKING Lime, moorum, building rubbish Cum 585 Included 0.00 0 0
72 995433 1.1.2 18% confirmed Carriage of materials by mechanical transport including loading, unloading and dumping: Earth-upto 2 km as directed by the Engineer-in-charge Cum 1257 Included 0.00 0 0
73 995433 1.1.4 18% confirmed Carriage of materials by mechanical transport including loading, unloading and dumping: Excavated rock upto 2 km as directed by the Engineer-in-charge Cum 206 Included 0.00 0 0
74 995433 2.6.1 18% confirmed Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineerin- charge. All kinds of soil cum 1850 Included 0.00 0 0
75 995433 2.7.1 18% confirmed Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge.Ordinary rock Cum 206 Included 0.00 0 0
76 995433 2.8.1 18% confirmed Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. Cum 501.2 Included 0.00 0 0
77 995433 2.25 18% confirmed Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. Cum 1178 Included 0.00 0 0
78 995433 2.25(a) + Mod 18% confirmed Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. Cum 500 Included 0.00 0 0
79 995433 2.26.2 18% confirmed Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. Ordinary or hard rock Cum 206 Included 0.00 0 0
80 995433 2.27 18% confirmed Supplying and filling in plinth with sand under floors including watering, ramming consolidating and dressing complete. cum 51.85 Included 0.00 0 0
81 995433 2.28.1 18% confirmed Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15cm deep and disposal of rubbish, lead upto 50m and lift upto 1.5m: All kind of soil. sqm 1000 Included 0.00 0 0
82 995433 2.34.1 18% confirmed Supplying chemical emulsion in sealed containers including delivery as specified - Chlorpyriphos/Lindane emulsifiable concentrate of 20% Litre 161.5 Included 0.00 0 0
83 995433 3.4 18% confirmed Cement mortar 1:4 (1 cement : 4 fine sand). Cum 10 Included 0.00 0 0
84 995433 4.1.3 18% confirmed Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) Cum 39 Included 0.00 0 0
85 995433 4.1.8 18% confirmed Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) Cum 155 Included 0.00 0 0
86 995433 4.1.10 18% confirmed 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) Cum 375 Included 0.00 0 0
87 995433 4.2.3 18% confirmed Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) CUM 0.85 Included 0.00 0 0
88 995433 4.2.5 18% confirmed Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc upto floor five level, excluding the cost of centring, shuttering and finishing: 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size). cum 1 Included 0.00 0 0
89 995433 4.3.1 18% confirmed Centring and shuttering including strutting, propping etc and removal of formwork for: Foundations, footings, bases of columns sqm 36.55 Included 0.00 0 0
90 995433 4.10 18% confirmed Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 12.5mm nominal size). sqm 23.8 Included 0.00 0 0
91 995433 4.13 18% confirmed Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. sqm 41.8 Included 0.00 0 0
92 995433 4.17 18% confirmed Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. sqm 80.75 Included 0.00 0 0
93 995433 5.1.2 18% confirmed Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Cum 558 Included 0.00 0 0
94 5.2.2 18% confirmed Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string course, fillets, columns, pillars, piers, abutments, posts and struts, etc. up to floor five level excluding cost of centring, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size). cum 12 Included 0.00 0 0
95 995433 5.3 18% confirmed Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15 degree, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral staircases up to floor five level excluding the cost of centring, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size). cum 22 Included 0.00 0 0
96 995433 5.8 18% confirmed Reinforced cement concrete work in Vertical and horizontal fins individually or forming box louvers, facias and eaves boards upto floor five level excluding cost of centring, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20mm nominal size). cum 2.55 Included 0.00 0 0
97 995433 5.9.1 18% confirmed Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete Sqm 138 Included 0.00 0 0
98 995433 5.9.2 18% confirmed Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc sqm 675 Included 0.00 0 0
99 995433 5.9.3 18% confirmed Centring and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform. sqm 408 Included 0.00 0 0
100 995433 5.9.4 18% confirmed Centring and shuttering including strutting, propping etc. and removal of form for: Shelves (Cast in Situ) sqm 136 Included 0.00 0 0
101 995433 5.9.5 18% confirmed Centring and shuttering including strutting, propping etc. and removal of form for: lintels, beam, plinth beams, girders, bressumers and cantilevers. sqm 388.45 Included 0.00 0 0
102 995433 5.9.6 18% confirmed Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts sqm 221 Included 0.00 0 0
103 995433 5.9.13 18% confirmed Centring and shuttering including strutting, propping etc. and removal of form for: Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards sqm 76.5 Included 0.00 0 0
104 995433 5.9.19 18% confirmed Centring and shuttering including strutting, propping etc. and removal of form for: Weather shade, Chajjas, corbels etc including edges. sqm 14.45 Included 0.00 0 0
105 995433 5.11.1 18% confirmed Extra for additional height in centring, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentring at all levels, over a height of 3.5m, for every additional height of 1 metre or part thereof (Plan area to be measured): Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). sqm 615.4 Included 0.00 0 0
106 995433 5.12 + Mod 18% confirmed Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in cover slabs, string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). CUM 3.875 Included 0.00 0 0
107 995433 5.22.6/5.22A.6 18% confirmed Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all level.Thermo-Mechanically Treated bars of grade Fe-500D or more Kg 46449 Included 0.00 0 0
108 995433 5.3 18% confirmed Add or deduct for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. metre 59.5 Included 0.00 0 0
109 995433 6.1.2 18% confirmed Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 90 Included 0.00 0 0
110 995433 6.4.2 18% confirmed Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) cum 63.75 Included 0.00 0 0
111 995433 6.12.2 18% confirmed Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in. cement mortar 1:4 (1 cement : 4 coarse sand) sqm 43.35 Included 0.00 0 0
112 995433 6.13.2 18% confirmed Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) sqm 106.25 Included 0.00 0 0
113 995433 6.15 18% confirmed Extra for providing and placing in position 2 Nos. 6mm MS bars at every third course of brick masonry (with F.P.S bricks) sqm 149.6 Included 0.00 0 0
114 995433 9.21.2 18% confirmed Providing and fixing ISI marked flush door shutters non-decorative type, core of block board construction with frame of Ist class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 30mm thick including ISI marked Stainless Steel butt hinges with necessary screws. sqm 5 Included 0.00 0 0
115 995433 9.23 18% confirmed Extra for providing lipping with 2nd class teak wood battens 25mm minimum depth on all edges of shutters (overall area of door shutter to be measured) sqm 5 Included 0.00 0 0
116 995433 9.42 18% confirmed Providing and fixing 18mm thick 150mm wide pelmet of flat pressed 3 layer (like Novapan, Ecoboard etc) or graded wood particle board (like Bhutan Board) medium density Grade 1, IS:3087 marked including top cover of 6mm commercial ply wood, nickel plated M.S. pipe 20mm dia (heavy type) curtain rod with nickel plated brackets including fixing with 25x3mm M.S. flat 10cm long and rawl plugs 50mm long (designation 10 no.) etc. all complete. metre 2 Included 0.00 0 0
117 995433 9.96.1 18% confirmed Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: Size 300 x 16mm each 1 Included 0.00 0 0
118 995433 9.96.2 18% confirmed Providing and fixing aluminium sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete: Size 250 x 16mm each 2 Included 0.00 0 0
119 995433 9.97.2 18% confirmed Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete: Size 250 x 10mm each 4 Included 0.00 0 0
120 995433 9.97.3 18% confirmed Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete: Size 200 x 10mm each 2 Included 0.00 0 0
121 995433 9.100.1 18% confirmed Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: Size: 125mm each 4 Included 0.00 0 0
122 995433 9.100.2 18% confirmed Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: Size 100mm each 2 Included 0.00 0 0
123 995433 9.101.2 18% confirmed Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: Twin rubber stopper each 2 Included 0.00 0 0
124 995433 10.14.1.1 18% confirmed Providing and fixing pressed steel door frames conforming to IS:4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25mm ,or base ties of 1.60 mm pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5mm thick with mortar guards, lock strikeplate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge: Profile B. Fixing with adjustable lugs with split end tail to each jamb. metre 17 Included 0.00 0 0
125 995433 10.17 18% confirmed Providing and fixing MS fan clamp type I or II of 16mm dia MS bar, bent to shape with hooked ends in RCC slabs or beams during laying including painting the exposed portion of loop, all as per standard design complete each 1 Included 0.00 0 0
126 995433 10.25.2 18% confirmed Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Kg 10151.5 Included 0.00 0 0
127 995433 11.5 18% confirmed 62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. sqm 348.5 Included 0.00 0 0
128 995433 11.6.1 18% confirmed Cement plaster skirting up to 30cm height, with cement mortar 1:3 (1 cement: 3 coarse sand), finished with a floating coat of neat cement: 18mm thick sqm 14.45 Included 0.00 0 0
129 995433 8.31 18% confirmed Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete sqm 14 Included 0.00 0 0
130 995433 11.37 18% confirmed Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete.. sqm 3 Included 0.00 0 0
131 995433 13.1.2 18% confirmed 12mm cement plaster of mix: 1:6 (1 cement: 6 fine sand) sqm 518.5 Included 0.00 0 0
132 995433 13.11 18% confirmed 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). Sqm 471.75 Included 0.00 0 0
133 995433 13.16.1 18% confirmed 6mm cement plaster to ceiling of mix: 1:3 (1 cement: 3 find sand) sqm 510 Included 0.00 0 0
134 995433 13.17 18% confirmed 6mm cement plaster 1:3 (1 cement: 3 find sand) finished with a floating coat of neat cement and thick coat of lime wash on top of walls when dry for bearing of RCC slabs and beams sqm 255 Included 0.00 0 0
135 995433 13.41.1 18% confirmed Distempering with 1st quality acrlic distemper(ready mixed) having VOC content less than 50gram/litre,of approved manufacturer and of required shade and colour all complete to achieve even shade and colour: New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50gram/litre. sqm 811.75 Included 0.00 0 0
136 995433 13.47.1 18% confirmed Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.9 ltr/10 sqm) Sqm 629 Included 0.00 0 0
137 995433 13.61.1 18% confirmed Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work sqm 200 Included 0.00 0 0
138 995433 13.62.1 18% confirmed Painting with synthetic enamel paint of approved brand and manufacture of required colour to given an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. sqm 602 Included 0.00 0 0
139 995433 13.65.1 18% confirmed Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : Two or more coats on new work Sqm 378 Included 0.00 0 0
140 995433 15.2.2 18% confirmed Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) CUM 300 Included 0.00 0 0
141 995433 15.3 18% confirmed Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. CUM 285 Included 0.00 0 0
142 995433 16.1 18% confirmed Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. SQM 375 Included 0.00 0 0
143 995433 16.30.1 + Modified 18% confirmed Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : 16.30.1 On W.B.M./W.M.M @ 0.75 Kg / sqm SQM 675 Included 0.00 0 0
144 995433 16.35 18% confirmed 2.5 cm premix carpet surfacing with 3 cum of stone chippings 10 mm nominal size per 100 sqm and bitumen emulsion (medium setting min. 65% bitumen contents) complying with IS : 8887, using 96 kg per cum of chippings of road surface, including consolidation with road roller etc complete . SQM 675 Included 0.00 0 0
145 995433 16.40. 18% confirmed Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. SQM 300 Included 0.00 0 0
146 995433 16.79 18% confirmed Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. CUM 85 Included 0.00 0 0
147 995433 17.2.1 18% confirmed Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid. each 1 Included 0.00 0 0
148 995433 17.7.2 18% confirmed Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap each 1 Included 0.00 0 0
149 995433 17.28.1.1 18% confirmed Providing and fixing PVC waste pipe for sink or wash basin including PVC waste fittings complete: Semi rigid pipe: 32mm dia each 1 Included 0.00 0 0
150 995433 17.32.2 18% confirmed Providing and fixing mirror of superior quality thickness of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing. Rectangular shape 453x357mm each 1 Included 0.00 0 0
151 995433 18.7.2 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.20 mm nominal dia Pipes metre 20 Included 0.00 0 0
152 995433 18.7.3 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.25 mm nominal dia Pipes metre 20 Included 0.00 0 0
153 995433 18.8.1 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls:15 mm nominal dia Pipes metre 10 Included 0.00 0 0
154 995433 18.8.2 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls:20 mm nominal dia Pipes metre 15 Included 0.00 0 0
155 995433 18.9.3 18% confirmed Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work,25 mm nominal dia Pipes metre 10 Included 0.00 0 0
156 995433 18.15.1 18% confirmed Providing and fixing brass bib cock of approved quality: 15mm nominal bore each 2 Included 0.00 0 0
157 995433 18.17.1 18% confirmed Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end): 25mm nominal bore each 1 Included 0.00 0 0
158 995433 18.18.3 18% confirmed Providing and fixing ball valve (brass) of approved quality complete. High or low pressure with plastic floats: 25mm nominal bore each 1 Included 0.00 0 0
159 995433 18.21.2.1 18% confirmed Providing and fixing unplasticised PVC connection pipe with brass unions. 45cm length. 15mm nominal bore each 1 Included 0.00 0 0
160 995433 18.32.1 18% confirmed Constructing masonry chamber 30x30x50cm inside ,in brick work in cement mortar 1:4 (1 cement: 4coarse sand) for stop cock, with C.I. surface box 100x100x75mm (inside) with hinged cover fixed in cement concrete slab 1:1.5:3 mix (1 cement: 1.5 course sand: 3 graded stone aggregate 20mm nominal size) including necessary excavation, foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement: 3 coarse sand) 12mm thick finished with a floating coat of neat cement complete as per standard design: With common burnt clay F.P.S.(Non Modular) bricks of class designation 7.5 each 1 Included 0.00 0 0
161 995433 18.48 18% confirmed Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank per litre 500 Included 0.00 0 0
162 995433 18.52.1 18% confirmed Providing and fixing C.P. brass stop cock (concealed) of standard design and of approve make conforming to IS:8931: 15mm nominal bore each 1 Included 0.00 0 0
163 995433 19.4.1.1 18% confirmed Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 1 Included 0.00 0 0
164 995433 19.6.1 18% confirmed Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 100 mm dia. R.C.C. pipe M 5 Included 0.00 0 0
165 995433 19.6.3+mod 18% confirmed Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :250 mm dia. R.C.C. pipe M 10 Included 0.00 0 0
166 995433 19.6.4+mod 18% confirmed Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete:300 mm dia. R.C.C. pipe M 10 Included 0.00 0 0
167 995433 19.7.1.1 18% confirmed Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 1 Included 0.00 0 0
168 995433 19.32.1 18% confirmed Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 each 1 Included 0.00 0 0
169 995433 19.35.1 18% confirmed Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete:450 mm dia. R.C.C. pipe M 10 Included 0.00 0 0
170 995433 21.1 18% confirmed Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : Included 0.00 0 0
171 995433 21.1.1.1 18% confirmed For fixed portion:Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) kg 240 Included 0.00 0 0
172 995433 21.1.2.1 18% confirmed For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868,Minimum anodic coating of grade AC 15) kg 200 Included 0.00 0 0
173 995433 21.8.1 18% confirmed Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete:Upto 5mm depth and 5 mm width metre 105 Included 0.00 0 0
174 995433 22.7.1 18% confirmed Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. sqm 442 Included 0.00 0 0
175 995428 100001714 18% confirmed Stone spreading in switchyard excluding PCC M2 4500 Included 0.00 0 0
176 995424 100001713 18% confirmed Antiweed treatment M2 11000 Included 0.00 0 0
177 995428 100001712 18% confirmed Removing,cleaning and washing of existing stones and respreading of stones in switchyard excluding PCC M2 7000 Included 0.00 0 0
178 995428 100001720 18% confirmed Supplying, filling and compacting CNS material as per specification under floors, foundations, roads, cable trenches, drains etc in layers not exceeding 200 mm thickness M3 100 Included 0.00 0 0
179 995428 100001721 18% confirmed Supplying, filling and compacting stone boulders mixed with sand under foundations,roads, cable trenches, drains etc in layers not exceeding 250mm thickness including ramming, watering, compacting etc. Cum 200 Included 0.00 0 0
180 995428 100001409 18% confirmed Supplying and erecting dewatering pumps-5 HP EA 1 Included 0.00 0 0
181 995428 100007701 18% confirmed Supplying and erecting dewatering pumps- 2 HP EA 1 Included 0.00 0 0
182 995433 NS-1 18% confirmed Soil Investigation for 02 borehole locations: As per technical specification including all laboratory and field tests, report andrecommendations. EA 1 Included 0.00 0 0
183 995433 NS-2 18% confirmed Supplying and fixing Rolling shutters of seamless galvalume motorized shutters with inclusion of features as mentioned below: slat material (shutter curtain) - min. 1.0mm steel slate (galvalume), slate profiles- min. 100mm wide, side guide- GI guides min. 75mm. (Especially design guides with wind locks for high wind velocity exposed shutters). Nylofelt seals fitted on the shutter skin for frictionless movement within the guides. Bottom profile- Aluminium bottom rail is provided with additional rubber seal for tight closing for dust entry. Roller shaft- Roller shaft shall be heavy duty mild steel strong suspension tubular shaft without springs. Side brackets- M.S. plate 3mm to 10mm as per the opensing dimension; surface finish & painting- Primer and Duco paint (matt finish); Operations-electrically operated (automation syatem) with motor suitable capacity along with manual operation by hand chain or hand crank for emergency including cost of materials, loading, undloading, transportaion all complete at site. SQM 12.5 Included 0.00 0 0
184 995433 NS-3 18% confirmed Providing and fixing 75 mm UPVC pipes conforming to IS : 15328, for weep holes and below road (heavy duty). m 20 Included 0.00 0 0
185 995433 NS-4 18% confirmed Providing and fixing 110 mm UPVC pipes conforming to IS : 15328, for jointing from drain/Cable trench to sump pit or similar works (heavy duty). m 20 Included 0.00 0 0
186 995433 NS-5 18% confirmed Providing & fixing mesh Arpita or equivalent made out of galvanized iron of nominal thickness 0.35 mm with a zinc coating of 120 gms per sqm along the junctions of masonry and concrete works including fixing,scaffolding,lead & lifts etc. Sqm 200 Included 0.00 0 0
187 995433 NS-6 18% confirmed Providing & fixing of Float glass panes of nominal thickness 5 mm/5.5mm to uPVC Window & door (weight not less than 12.50 kg/sqm) as per direction of Engineer Incharge Sqm 46 Included 0.00 0 0
188 995433 NS-7 18% confirmed Diluting and injecting chemical emulsion (excluding of the cost of the chemical emulsion) for PRE-CONSTRUCTIONAL ANTI-termite treatment and creating a continuous chemical barrier under and all-round the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surroundings of pipes and conduits etc. complete as per specifications (Plinth area of the building at ground floor only shall be measured for payment). (Only application charges shall be paid under this item) Chlorpyriphos / Lindane Emulsifiable concentrate 20% with 1% concentration. sqm 597.55 Included 0.00 0 0
189 995433 NS-8 18% confirmed Providing and fixing stainless steel gratings with or with out hole for waste pipe for floor/nahni traps 100mm dia. Each 1 Included 0.00 0 0
190 995433 NS-9 18% confirmed Providing and fixing PVC floor trap including cost of cutting and making good the walls and floors: 100 mm inlet and 75mm outlet Each 1 Included 0.00 0 0
191 995433 NS-10 18% confirmed Supplying, laying,jointing ,testing and commisioning approved make upvc pipes SWR grade B conforming to IS 13592.The quoted rates shall include necessary fittings like Tees, bends, offsets etc. including MS angle with GI clamps complete: 110 mm dia Metre 50 Included 0.00 0 0
192 995433 NS-11 18% confirmed Supplying, laying,jointing ,testing and commisioning approved make upvc pipes SWR grade B conforming to IS 13592.The quoted rates shall include necessary fittings like Tees, bends, offsets etc. including MS angle with GI clamps complete: 75 mm dia Metre 20 Included 0.00 0 0
193 995433 NS-12 18% confirmed Supplying,installing,testing and commissioning approved make 15 mm CP health faucet with CP flexible tube 1.0 m long,CP crutch,nozzle and 2- way Bib Cock with wall flange etc. complete. Jaquar Model No. 573 and 041 or equivalent. Nos 1 Included 0.00 0 0
C Civil works at Pugalur Station-Reconductoring of Tirunelveli -Udumalpet and Pugalur – Madurai 400kV D/c lines with HTLS conductor 0.18 confirmed Included 0.00 0 0
194 995433 1.1.1 18% confirmed CARRIAGE OF MATERIALS: BY MECHANICAL TRANSPORT INCLUDING LOADING,UNLOADING AND STACKING Lime, moorum, building rubbish Cum 585 Included 0.00 0 0
195 995433 1.1.2 18% confirmed Carriage of materials by mechanical transport including loading, unloading and dumping: Earth-upto 2 km as directed by the Engineer-in-charge Cum 1243 Included 0.00 0 0
197 995433 1.1.4 18% confirmed Carriage of materials by mechanical transport including loading, unloading and dumping: Excavated rock upto 2 km as directed by the Engineer-in-charge Cum 136 Included 0.00 0 0
198 995433 2.6.1 18% confirmed Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineerin- charge. All kinds of soil cum 1165 Included 0.00 0 0
199 995433 2.7.1 18% confirmed Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-Charge.Ordinary rock Cum 136 Included 0.00 0 0
200 995433 2.8.1 18% confirmed Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. Cum 619.55 Included 0.00 0 0
201 995433 2.25 18% confirmed Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. Cum 591 Included 0.00 0 0
202 995433 2.25(a) + Mod 18% confirmed Excavating, supplying, stacking and filling of local earth by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. Cum 500 Included 0.00 0 0
203 995433 2.26.2 18% confirmed Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. Ordinary or hard rock Cum 136 Included 0.00 0 0
204 995433 2.28.1 18% confirmed Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15cm deep and disposal of rubbish, lead upto 50m and lift upto 1.5m: All kind of soil. sqm 1000 Included 0.00 0 0
205 995433 3.4 18% confirmed Cement mortar 1:4 (1 cement : 4 fine sand). Cum 10 Included 0.00 0 0
206 995433 4.1.3 18% confirmed Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) Cum 3 Included 0.00 0 0
207 995433 4.1.8 18% confirmed Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) Cum 167 Included 0.00 0 0
208 995433 4.1.10 18% confirmed 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) Cum 375 Included 0.00 0 0
209 995433 4.2.5 18% confirmed Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets etc upto floor five level, excluding the cost of centring, shuttering and finishing: 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size). cum 1 Included 0.00 0 0
210 995433 4.13 18% confirmed Applying a coat of residual petroleum bitumen of penetration 80/100 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. sqm 18 Included 0.00 0 0
211 995433 5.1.2 18% confirmed Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) Cum 448 Included 0.00 0 0
212 995433 5.9.1 18% confirmed Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete Sqm 78 Included 0.00 0 0
213 995433 5.9.2 18% confirmed Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc sqm 675 Included 0.00 0 0
214 995433 5.12 + Mod 18% confirmed Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in cover slabs, string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). CUM 3.875 Included 0.00 0 0
215 995433 5.22.6/5.22A.6 18% confirmed Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all level.Thermo-Mechanically Treated bars of grade Fe-500D or more Kg 37449 Included 0.00 0 0
216 995433 6.1.2 18% confirmed Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) Cum 114 Included 0.00 0 0
217 995433 10.25.2 18% confirmed Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Kg 8934 Included 0.00 0 0
218 995433 13.61.1 18% confirmed Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work sqm 200 Included 0.00 0 0
219 995433 13.62.1 18% confirmed Painting with synthetic enamel paint of approved brand and manufacture of required colour to given an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. sqm 500 Included 0.00 0 0
220 995433 13.65.1 18% confirmed Painting with black anti-corrosive bitumastic paint of approved brand and manufacture to give an even shade : Two or more coats on new work Sqm 378 Included 0.00 0 0
221 995433 15.2.2 18% confirmed Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) CUM 300 Included 0.00 0 0
222 995433 15.3 18% confirmed Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. CUM 285 Included 0.00 0 0
223 995433 16.1 18% confirmed Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. SQM 750 Included 0.00 0 0
224 995433 16.30.1 + Modified 18% confirmed Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : 16.30.1 On W.B.M./W.M.M @ 0.75 Kg / sqm SQM 750 Included 0.00 0 0
225 995433 16.35 18% confirmed 2.5 cm premix carpet surfacing with 3 cum of stone chippings 10 mm nominal size per 100 sqm and bitumen emulsion (medium setting min. 65% bitumen contents) complying with IS : 8887, using 96 kg per cum of chippings of road surface, including consolidation with road roller etc complete . SQM 750 Included 0.00 0 0
226 995433 16.79 18% confirmed Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achievethe desired density, complete as per specifications and directions of Engineer-in-Charge. CUM 169 Included 0.00 0 0
227 995433 19.6.1 18% confirmed Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 100 mm dia. R.C.C. pipe M 5 Included 0.00 0 0
228 995433 19.6.3+mod 18% confirmed Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete :250 mm dia. R.C.C. pipe M 20 Included 0.00 0 0
229 995433 19.6.4+mod 18% confirmed Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete:300 mm dia. R.C.C. pipe M 20 Included 0.00 0 0
230 995433 19.35.1 18% confirmed Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete:450 mm dia. R.C.C. pipe M 20 Included 0.00 0 0
231 995428 100001714 18% confirmed Stone spreading in switchyard excluding PCC M2 4500 Included 0.00
232 995424 100001713 18% confirmed Antiweed treatment M2 11000 Included 0.00
233 995428 100001712 18% confirmed Removing,cleaning and washing of existing stones and respreading of stones in switchyard excluding PCC M2 7000 Included 0.00
234 995428 100001720 18% confirmed Supplying, filling and compacting CNS material as per specification under floors, foundations, roads, cable trenches, drains etc in layers not exceeding 200 mm thickness M3 125 Included 0.00
235 995428 100001721 18% confirmed Supplying, filling and compacting stone boulders mixed with sand under foundations,roads, cable trenches, drains etc in layers not exceeding 250mm thickness including ramming, watering, compacting etc. Cum 255 Included 0.00
236 995428 100001409 18% confirmed Supplying and erecting dewatering pumps-5 HP EA 1 Included 0.00
237 995428 100007701 18% confirmed Supplying and erecting dewatering pumps- 2 HP EA 1 Included 0.00
238 995433 NS-3 18% confirmed Providing and fixing 75 mm UPVC pipes conforming to IS : 15328, for weep holes and below road (heavy duty). m 20 Included 0.00
239 995433 NS-4 18% confirmed Providing and fixing 110 mm UPVC pipes conforming to IS : 15328, for jointing from drain/Cable trench to sump pit or similar works (heavy duty). m 20 Included 0.00 0 0
GST Amount 0.00
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546) Schedule - 4
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(SCHEDULE OF RATES AND PRICES )
Bidder’s Name and Address (Lead Partner) : To:
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore -560064
Training Charges for Training to be imparted
TOTAL TRAINING CHARGES 0.00
Date : -- Printed Name :
Place : Designation :
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546) Schedule - 5
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(SUMMARY OF TAXES & DUTIES APPLICABLE ON PLANT & EQUIPMENT)
Bidder’s Name and Address (Lead Partner) : To:
Sr.General Manager,
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore -560064
Sl. No. Item Nos. Total Price (INR) After Discount After MPDiscount
1 TOTAL GST ON SUPPLY(Sch-1) 0.00 Sales Tax 0.00 Sales Tax 0.00
2 TOTAL GST ON SERVICES (Sch-3) 0.00
GRAND TOTAL [] 0.00 Grand Total after Discount #REF! Grand Total after MPD #REF!
Date : --2026 Printed Name :
Place : Designation :
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546) Schedule - 5
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
SUMMARY OF TAXES & DUTIES APPLICABLE ON GOODS
Bidder’s Name and Address (Lead Partner) : To:
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore -560064
Sl. No. Item Nos. Total Price (INR)
1 TOTAL GST ON GOODS #REF!
Total GST for Supply of Goods (inter-alia including Type Test Charges) between the Contractor and the Employer (identified in Schedule 1') which are not included in the Ex-works price as per the provision of the Bidding Documents, as applicable.
2 TOTAL GST ON SERVICES #REF!
Total GST on Installation Services (Schedule-3) and Training to be imparted in India (Schedule-4)
GRAND TOTAL [1+2] #REF!
Date : --2026 Printed Name :
Place : Designation :
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546) Schedule - 6
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(GRAND SUMMARY)
Bidder’s Name and Address (Lead Partner) : To:
Sr.General Manager,
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore -560064
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 0.00
Ex-works price of Plant and Equipment
2 TOTAL SCHEDULE NO. 2 0.00
Local Transportation, Insurance and other Incidental Services (including GST, if any)
3 TOTAL SCHEDULE NO. 3 0.00
Total Installtion/Service Charges
4 TOTAL SCHEDULE NO. 4 0.00
Training Charges
4 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties(GST)
6 TOTAL SCHEDULE NO. 7 0.00
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2] 0.00
Date : --2026 Printed Name :
Place : Designation :
This letter of discount is optional. Bidder may / may not offer any discount.
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546) Letter of Discount
LETTER OF DISCOUNT
Contract Services
Power Grid Corporation of India Ltd.,
"Saudamini", Plot No.-2
Sector-29, (near IFFCO Chowk)
Gurgaon (Haryana) - 122001
Subject : WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
With reference to the subject tender, we hereby offer unconditional discount on the prices quoted by us as per details given here below : Eq Weightage of Rs/ % Final Discount Factor
1 Discount on lum-sum basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2, Sch-3 & Sch-7] In Rs. #REF! #REF!
2 Discount on percent basis on total price quoted by us without Taxes & Duties. [The discount shall be proportionately applicable on all the items of all the Schdules i.e. Sch-1 (without type test charges), Sch-2 , Sch-3 & Sch-7] In Percent (%) #REF! 0.00%
3 Discount on lum-sum basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Rs.
Schedule-1 : Ex works prices In Rs. 0.00 0.0000000000% Schedule-1 : (Direct Only) #REF!
Schedule-2 : Freight & Insurance In Rs. 0.00 0.0000000000% Schedule-2 : Freight & Insurance #REF!
Schedule-1 : Erection Charges In Rs. #REF! #REF! Schedule-3 : Erection Charges #REF!
Schedule-4 : Training Charges In Rs. 0.00 0.0000000000% Schedule-4 : Training Charges #REF!
Schedule-7 : Type Test Charges In Rs. 0.00 0.0000000000% Schedule-6 : Type Test Charges #REF!
1 Discount on percent basis on the Schedules as given below : [The discount shall be proportionately applicable on all the relevent items of the respective Schdules.] In Percent (%)
Schedule-1 : Ex works prices In Percent (%) 0.00 0.00%
Schedule-2 : Freight & Insurance In Percent (%) 0.00 0.00%
Schedule-1 : Erection Charges In Percent (%) #REF! 0.00%
Schedule-4 : Training Charges In Percent (%) 0.00 0.00%
Schedule-7 : Type Test Charges In Percent (%) 0.00 0.00%
Discount(s) offered at sl. No. 1 will get displayed and accounted for automatically in the respective items of the Schedules.
5 We hereby offer Multi-package discount as given below:
Multi-Package Discount(s) offered at sl. No. 5 will not get automatically accounted for in the respective items of the Schedules. The same shall be worked out saparately for evaluation.
Please consider this letter of discount as the integral part of our price bid.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : --2026 Printed Name :
Place : Designation :
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546) Schedule - 6 After Discount
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(GRAND SUMMARY)
Bidder’s Name and Address (Lead Partner) : To:
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore -560064
Sl. No. Description Total Price (INR)
1 TOTAL SCHEDULE NO. 1 #REF!
Ex-works price of Plant and Equipment
2 TOTAL SCHEDULE NO. 2 #REF!
Local Transportation, Insurance and other Incidental Services (including GST, if any)
1 TOTAL SCHEDULE NO. 1 #REF!
Total Charges for Site Levelling works
4 TOTAL SCHEDULE NO. 4 #REF!
Training Charges
2 TOTAL SCHEDULE NO. 5 0.00
Taxes and Duties(GST)
6 TOTAL SCHEDULE NO. 7 #REF!
Type Test Charges [Total of this Schedule is included in Schedule - 1 above.]
GRAND TOTAL [1+2] #REF!
Date : --2026 Printed Name :
Place : Designation :
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546) Schedule 7
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES ) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-7 #REF!
C&M Department Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka Multipackage Discount #REF!
Bangalore -560064
Type test Charges
SL. NO. Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) #REF! Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
TOTAL TYPE TEST CHARGES 0.00
Dis Alert #REF!
Date : --2026 Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546)
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor. 0 0 0
(SCHEDULE OF RATES AND PRICES ) 0 0 0
Bidder’s Name and Address (Lead Partner) : 0
SL. NO. Description of Test 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546)
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor. As per Lum-sum 0.00%
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) AS per Percent #REF!
As per lum-sum on Sch-7 0.00%
Bidder’s Name and Address (Lead Partner) : To: As per Percent on Sch-7 #REF!
C&M Department Total Discount #REF!
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka Multipackage Discount #REF!
Bangalore -560064
Type Tests on Earthwire
SL. NO. Description of Test Unit Quantity Unit Test Charge Total Test Charges (Rs.) Total Test Charges After Discount (Rs.) Dis Alert Total Test Charges After MPD (Rs.)
(a) #REF! #REF! #REF! #REF! #REF!
(b) #REF! #REF! #REF! #REF! #REF!
Sub-Total (I) #REF!
TOTAL TEST CHARGES (I) #REF!
Discount Sche-7 #REF! MPD Sche-7 #REF!
Dis Alert #REF!
Date : --2026 Printed Name :
Place : Designation :
Note : Bidder should indicate the name of test laboratories where type tests are proposed to be conducted
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546)
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor. 0 0 0
(SCHEDULE OF RATES AND PRICES : TYPE TEST CHARGES) 0 0 0
Bidder’s Name and Address (Lead Partner) : 0
SL. NO. Description of Test 0
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
Details of Octroi
Sl No. Description of Items Amount on which Octroi is applicable Rate of Octroi Octroi
Details of Entry Tax
Sl No. Description of Items Amount on which Entry Tax is applicable Rate of Entry Tax Entry Tax
Details of Other Taxes & Duties
Sl No. Description of Items Amount on which Other Taxes & Duties are applicable Description of Taxes & Duties Rate of Taxes & Duties Amount of Taxes & Duties
SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546) Bid Form 2nd Envelope Others 1 st 1 January
0 2 nd 2 February
BID FORM (Second Envelope) 3 rd 3 March
Bid Proposal Ref. No. 5 th 5 May
Date : --2026 6 th #VALUE! 6 June
7 th #VALUE! 7 July
To: 8 th #VALUE! 8 August
Sr.General Manager,
C&M Department 9 th #VALUE! 9 September
Power Grid Corporation of India Ltd., 10 th 10 October
SR-II,RHQ 11 th 11 November
Singanayakanahalli,Yelahanka 12 th 12 December
Bangalore -560064 13 th
Name of Contract : WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor. 15 th
Dear Ladies and/or Gentlemen, 16 th
1.0 In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) under the above-named package in full conformity with the said Bidding Documents for the sum of Rs. _____________ or such other sums as may be determined in accordance with the terms and conditions of the Bidding Documents. In continuation of First Envelope of our Bid, we hereby submit the Second Envelope of the Bid, both of which shall be read together and in conjunction with each other, and shall be construed as an integral part of our Bid. Accordingly, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial Operation, Performance & Guarantee Test as per provision of Technical Specification) under the above-named package in full conformity with the said Bidding Documents for the sum of Rs. or such other sums as may be determined in accordance with the terms and conditions of the Bidding Documents. _____________ 17 th
Schedule 1 Plant and Equipment to be supplied. 21 st
Schedule 2 Local Transportation, In-transit Insurance, loading and unloading 22 th
Schedule 3 Installation Charges. Others 23 th
Schedule 4 Training charges for training to be imparted. Not applicable 24 th
Schedule 5 Taxes and Duties not included in Schedule 1&3 25 th
Schedule 6 Grand Summary [Schedule 1to 5] 26 th
Schedule 7 Break-up of Type Test Charges for Type Tests to be conducted-Not applicable 27 th
2.4 We declare that items left blank in the Schedules will be deemed to have been included in other items. The TOTAL for each Schedule and the TOTAL of Grand Summary shall be deemed to be the total price for executing the Facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced. 31 st
3.0 We confirm that except as otherwise specifically provided our Bid Prices in this Second Envelope include all taxes, duties, levies and charges as may be assessed on us/our Associate (applicable for Foreign Bidder), our Sub-Contractor/Sub-Vendor or their employees by all municipal, state or national government authorities in connection with the Facilities, in and outside of India.
3.1 100% of applicable Taxes and Duties i.e GST, which are payable by the Employer under the Contract, shall be reimbursed by the Employer on production of satisfactory documentary evidence by the Contractor in accordance with the provisions of the Bidding Documents.
3.3 We confirm that we have also registered/we shall also get registered in the GST Network with a GSTIN, in all the states where the project is located and the states from which we shall make our supply of goods.
4.0 # (For Joint Venture only) We, the partners of Joint Venture submitting this bid, do agree and confirm that in case of Award of Contract on the Joint Venture, we shall be jointly and severally liable and responsible for the execution of the Contract in accordance with Contract terms and conditions. 2
4.0 We, hereby, declare that only the persons or firms interested in this proposal as principals are named here and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if the award is made on us, that this proposal is made without any connection with any other person, firm or party likewise submitting a proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : --2026 Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him.
Please provide additional information of the Bidder
Business Address :
Country of Incorporation :
State/Province to be indicated :
Name of Principal Officer :
Address of Principal Officer :
Note: Bidders may note that no prescribed proforma has been enclosed for Attachment 2 : Power of Attorney. Bidders may use their own proforma for furnishing the required information with the bid.
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges 0.00 0.00
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) 0.00 0.00
6 DISCOUNT #REF! #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY #REF! 0.00
B) CENTRAL SALES TAX #REF! 0.00
C) VAT #REF! 0.00
D) ENTRY TAX / OCTROI #REF! 0.00
F) TOTAL TAXES & DUTIES #REF! 0.00
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! 0.00
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] 0.00 0.00
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
#REF! Excise Duty #REF! #REF!
#REF! CST #REF! #REF!
#REF! VAT #REF! #REF!
#REF! Entry Tax/ Octroi #REF! #REF!
Others as Others
II) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 2% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated :
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. 0
b) Excise Duty, as applicable on (a) above at the rate : 10.00% Rs. 0
c) Amount on which Sales Tax is applicable 0.00 0
d) CST, as applicable on (a) + ED (b) above at the rate : 2.00% Rs. 0
e) VAT, as applicable on (a) + ED (b) above at the rate : 1.00% 0
g) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. 0
h) Entry Tax, as applicable on (e) above at the rate : Rs. 0.00
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor. Statement of Quoted / Corrected Prices Page
Spec. No. SPECIFICATION No.: SR2/NT/W-AIS/DOM/C00/26/10293, (RFx No. 5002005546)
STATEMENT OF QUOTED / CORRECTED PRICES
All Figures are in Rupees
Sl. No. Price Component Quoted Price Corrected Price
1 TOTAL SCHEDULE NO. 1:Ex-Works Price of Plant and Equipment including Type Test Charges 0.00 0.00
2 TOTAL SCHEDULE NO.2: Local Transportation, Insurance and other Incidental Services. 0.00 0.00
3 TOTAL SCHEDULE NO.3: Installation Charges 0.00 0.00
4 TOTAL SCHEDULE NO.4: Training Charges Not Applicable Not Applicable
5 TOTAL BID PRICE: (Excluding Taxes & Duties) 0.00 0.00
6 DISCOUNT #REF! #REF!
7 NET BID PRICE (Excluding Taxes & Duties) #REF! #REF!
8 TAXES & DUTIES PAYABLE ADDITIONALLY
A) EXCISE DUTY #REF! #REF!
B) CENTRAL SALES TAX /VAT #REF! #REF!
C) ENTRY TAX / OCTROI #REF! #REF!
D) OTHERS #REF! 0.00
E) TOTAL TAXES & DUTIES #REF! #REF!
8 TOTAL BID PRICE (INCLUDING TAXES & DUTIES) #REF! #REF!
9 TOTAL SCHEDULE NO.7: Type Test Charges [Total of this Schedule is included in Schedule-1 above] 0.00 0.00
I) Bidder has indicated the following taxes and duties additionally applicable for their bid:
a) Excise Duty Rs. #REF!
b) CST /VAT Rs. #REF!
c) Entry Tax / Octroi Rs. #REF!
d) Others Rs. #REF!
II) Bidder has offered following discount(s)
III) With regard to Entry Tax, it may be mentioned that the substations covered under the subject pacakge falls in State of MP, where an entry tax @ 1% of Purchase Price is applicable. In view of the above, the taxes and duties inter-alia including entry tax applicable for the bids are calculated : Details of dicounts
a) Ex-Works Price of Direct Supplies (after discount, if any) Rs. #REF! Gross LS #REF! #REF! #REF! Gross % #REF! #REF! #REF!
b) Excise Duty @ 10.3% of (a) above Rs. #REF! #REF! #REF!
c) CST / VAT @ 2% of Ex-Works of Direct Supplies (a) + ED (b) above Rs. #REF! Sch-1 Direct LS #REF! #REF! #REF! Sch-1 Direct % #REF! #REF! #REF!
d) Others Rs. Sch-1 BO LS #REF! #REF! #REF! Sch-1 BO % #REF! #REF! #REF!
e) Purchase Price for Entry Tax (Total Ex-Works+F&I+ED+CST+Others) Rs. #REF! Sch-2 LS #REF! #REF! #REF! Sch-2 % #REF! #REF! #REF!
f) Entry Tax @ 1% of (e) above Rs. #REF! Sch-3 LS #REF! #REF! #REF! Sch-3 % #REF! #REF! #REF!
Sch-7 LS #REF! #REF! #REF! Sch-7 % #REF! #REF! #REF!
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor. Statement of Quoted / Corrected Prices Page Different Manner #REF!
Text for Discount #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
Name of Package : WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546)
Completion Period 12 Months
: Attachments : General guidelines for filling up the Attachments :Works Package - :
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546)
1 Fill up only green shaded cells in the relevant attachments.
2 Attachments 3(JV)4, A(A),5,5(A),6,(A),6(B),6(C),6(D),7,9,10,11,12,13,14(IP),15,16,17,19 and bid form for first envelope are included here.
3 Attachment 1 Bid Security : Not Applicable.
4 Attachment 2 Power of Attorney : No specific format is provided by POWERGRID. Bidder may use their own format.
5 Attachment 11 Integrity Pact : To be submitted as per ITB Clause No. 9.3(m) and as per remarks in the Attach 11-IP.
5 Attachment-3 (QR Schedule)- Format attached here (Also in Vol-III of bidding documents)
6 Attachment-8 Manufacturer's Authorisation form- To be furnished as per proforma provided in the bidding document, on the letter head of each manufacturer's proposed to supply the main items. Not included here & attached in Vol-III of Bid documents
7 Attachment-18 - Safety pact- To be submitted as per ITB clause no. 9.3(s) and as per the remarks mentioned in the safety pact atatched in Vol-II of Bid documents
8 Attachment 20 to 29- To be submitted as per pre-proforma submitted in Vol-III of bid document.
6 Attachment-16: Undertaking regarding submission of Original/ Hardcopy of the bid shall be uploaded.
Note : Enable the Active X Control & Macros. Also ensure to keep option of "Trust acess to VBA project object Model" cheched [√]. Ensure that you work on MS Excel 2007 or higher version.
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Properitary Firm 1
Partnership Firm 2 or More
Enter following details of the bidder Private Limited
Specify type of Bidder [Select from drop down menu] 2 or More
Name of Authorised Person
Address of Registered Office
Other Partner-1
Address of other Partner - 1
Name of other Partner - 2 (More, if any)
Address of other Partner - 2 (More, if any)
Note : In case of JV, all partners of the joint venture shall be MSE's to consider its bid as bid from MSE , JV bidder with atleast one atleast non-MSE partner (Whether lead or other partner) shall NOT be eleigible for the benefit eligible to MSE bidders.
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment-3(JV) 0 0
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Joint Venture Agreement and Power of Attorney for Joint Venture*)
Bidder’s Name and Address (Authorised Person) : To :
Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore-560064
The Joint Venture Agreement (as per the proforma attached at Annexure -I, Special Conditions of Contract, Vol.-I of the Bidding Documents) and Power of Attorney for Joint Venture (as per the proforma attached at Annexure -II, Special Conditions of Contract, Vol.-I of the Bidding Documents) are enclosed herewith.
Place : Designation : 12
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment- 3 (QR)
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Qualifying Requirement Data)
Bidder’s Name and Address (Authorised Person) : To :
Sr. General Manager(C&M)
Name: Power Grid Corporation of India Ltd.,
Address: SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore-560064
In support of the Qualification Requirements (QR) for bidders, stipulated in Annexure-A (BDS) of the Section - III (BDS), Volume-I & additional information required as per ITB clause 9.3(c) of the Bidding Documents, we furnish herewith our QR data/details/documents etc., alongwith other information, as follows (The QR stipulations have been reproduced in italics for ready reference, however, in case of any discrepancy the QR as given in BDS shall prevail). The copies of Work completion certificates along with copy of work order/Agreements, Financial statements were self attested by Power of Attornery who is submitting this bid and the same is uploaded as First Envelope(Techno Commercial bid)
[For details regarding Qualification Requirements of a Joint Venture, please refer para 4.0 below.]
We are furnishing the following details/document in support of Qualifying requirement for the subject package.
A Attached copies of original documents of Sole Bidder in PDF format.
a) The constitution or legal status;
b) The principal place of business;
c) The place of incorporation (for bidders who are corporations); or the place of registration and the nationality of the Owners (for applicants who are partnerships or individually-owned firms).
a) Bidders submitting their Bids in Joint Venture may note that they have to furnish the JV Agreement and Power of Attorney of JV in line with the provisions of Bidding Document alongwith Bid Security and Integrity Pact in physical form before deadline for submission of hard copy of documents.
b) Attach written Power of Attorney of the Signatory of the Bid (For sole bidder / Lead Partner of the JV) and signatories of other partners of the JV (Signing the JV Agreement / Attorney of the JV)
d) We also uploaded Declaration form jointly signed by Power of Attorney holder with Key Managerial Personnel(KMP) of the company i.e CEO/Manager Director/Company Secretary/Director/CFO/any other partner in case of Partnership firm declaring the QR data to true and correct
1.0 GENERAL INFORMATION
Bidder is required to provide general information as per the following format.
[Where the Bidder proposes to use named subcontractor(s) for critical components of the works or for work contents in excess of ten (10) percent of the bid price, the following information should also be supplied for the subcontractor(s)].
S No. Particulars
1 Name of the Firm
2 Legal Status Properitorship
3 Head Office/ Registered Office Address
6 Contact Person
7 Place of Incorporation/ Registration
8 Year of Incorporation/ Registration
9 Nationality of
2.0 TECHNICAL REQUIREMENTS
2.1 Technical Experience
S.No Details of works executed Completion value Work order Ref Details work completion Certicate Whether uploaded
2.1.1 {Reference CL.1.0 of Annexure-A (BDS)}
2.1.2 Using the following format, each Bidder (individual firms or partners of a joint venture) is requested to list the contracts of a nature similar to the proposed contract for which the Bidder wishes to qualify, undertaken during the last seven (7) years. The information is to be summarised for each such contract separately. (In case of Joint Venture bidder, the information/details pertaining to each partners of the joint venture are to be furnished).
[In support of above bidder should required to provide documentary evidence like copies of Final time extension/Performance Certificate/TOC/Completion Certificate , along with corresponding work/purchase order etc. Such documents need to be uploaded as attachment.]
Format for individual firm or for different Partner of a Joint Venture (JV):
Bidder’s Name : 0 0 0
Address : 0 0 0
Single Firm/Lead Partner/Other Partners of a JV : Other Partner of a JV Other Partners of a JV Other Partners of a JV
a Name of Contract Undertaken/Name of Transmission line/projects
b Contract Reference No. & Date of Award
c Name and Address of the Employer/Utility for whom the Contract was executed by the firm/Partner of a JV
d Scope of work executed under the above contract (as in Sl No (i) of 2.1.1) (Tick only whichever is/are applicable)
e Capacity in which the Contract was undertaken (Select One from Drop Down)
f If Contract was taken as JV partner scope of partner
g Date of Completion of Contract
h Details of documents furnished in the Bid, in support of the aforesaid data/ details/ information
3.0 Financial requirement
3.1 {Reference Cl.2.0 of Annexure-A (BDS)}
For the purpose of this particular bid, bidders shall meet the following minimum criteria
a) (a) Minimum Average Annual Turnover* (MAAT) of the bidder for best 03 (Three) years i.e. 36 (Thirty-Six) months out of last 07 (Seven) financial years as annualized should be ₹.2830.87 Lakhs
Note: -Annual total income as incorporated in the profit & loss account except non-recurring income e.g. sale of fixed assets.
b) (b) Bidder shall have Liquid Assets or/and evidence of access to or availability of credit facilities of not less than ₹. 471.81 Lakhs
c) (c) Net Worth for the last 03 (three) financial years should be positive.
3.2 In support of its ‘Financial Position’, in line with the above, the Bidder must provide the relevant information, alongwith documentary evidence, in the following formats A & B:
Description For a joint venture of firms
For Lead Partner
Name of the Bidder
A Average Annual Turnover details:
Sl. No. Financial year
Average Annual Turnover for best Three Years out of last seven financial years is
B Liquid Assets
Details of evidence of having Liquid assets (LA)
Details of evidence of access to or availability of credit facilities
Note: Bidder should get all the above parameters at clause 3.2 i.e. Financial Position duly certified by a Chartered Accountant and get a letter regarding availability of credit facilities and utilization statement from their banker and submit the same at the time of issuance of tender documents.
In case bidder is a holding company, MAAT & LA referred to in clause (a) & (b) above shall be that of holding company only (i.e., excluding its subsidiary/group companies). In case bidder is a subsidiary of a holding company, MAAT & LA referred to in clause (a) & (b) above shall be of that subsidiary company only (i.e., excluding its holding company).
[Further, for joint venture bidders, the requirement to be met is stipulated under part-B under sub-heading Joint Venture Firms of Annexure-A of (BDS).]
4.0 Joint Venture (JV) Firms
4.1 (a) a) In case a bid is submitted by a Joint Venture (JV) of two or more firms as partners, joint venture must comply with the following minimum criteria:
i) i) All the partners of the JV shall meet individually the Financial Position criteria given at 2.0 (c) above.
i) ii) The lead partner shall meet, not less than 40% of the Financial Position criteria specified at Para 2.0 (a) & 2.0 (b) above and 100% of the Technical Experience criteria given at 1.0 above.
a) Each of the other partner (s) individually
(b) a) shall meet not less than 25% of the Financial Position criteria given at specified at Para 2.0 (a) & 2.0 (b) above..
(i) b) Bidder must have executed civil works, erection, testing and commissioning of at least 1 ( One ) no. AIS^ Circuit Breaker equipped bay of 220kV or above voltage level in one (1) substation or switchyard during last seven (7) years under a single contract as a Prime contractor or as a Sub-Contractor and these bays must be in satisfactory operation# as on originally scheduled date of the bid submission, i.e. As on 07.09.2026
(ii) iii) The joint Venture must satisfy collectively the Criteria of clause 2.0 (a) & 2.0 (b) above for which purpose the relevant figure of average annual turnover and liquid assets / credit facilities for each of the partners of the JV shall be added together to arrive at Joint Venture total capacity.
Note (*): In case of works executed under a contract that had been awarded on a Joint Venture, the experience of individual Joint Venture partner shall be considered limited to the scope of that partner under the said contract
#Satisfactory operation means certificate issued by the Employer certifying the operation without any adverse remark.
4.2 In accordance with the above, in case of JV bidders, it should be ensured that necessary details including those pertaining to each JV partner are furnished and the corresponding documents are attached. Further, the JV bidders should also ensure that other requirements are complied with. The lists of documents attached are to be indicated below:
(i) Doc Name KRA.pdf
(ii) F:\KRA.pdf
(iii) F:\KRA.pdf
5.0 The Bidder shall also furnish following documents/details with its bid. {Reference ITB clause 8.3 (c)}
5.1 The Bidder shall provide satisfactory evidence to POWERGRID, of their capability and adequacy of resources to carry out the Contract effectively. Accordingly, bids shall include the following documentary evidences / information
For Technical Experience
a) Completion certificate(s) detailing the scope of works / project completed covering the works as defined for “similar works” and showing the completed value, period of execution of the project completed
For Financial Status:
(a) Complete Annual report along with the Audited Statement of Accounts comprising of Balance Sheets and Profit & Loss Account of the company (of its own, if the company is holding or subsidiary) as applicable for 03 (Three) years immediately preceding the date of submission of the ‘Sealed Bid’
Note – I: IIn the event the Bidder is not able to furnish the information of its own (i.e. separate), being a subsidiary company and its accounts are being consolidated with its group/ holding/ parent company, the bidder should submit the audited balance sheets, income statements, other information pertaining to it only (not of its group / Holding / Parent Company) duly certified by any one of the authority [ (i) Statutory Auditor of the bidder /(ii) Company Secretary of the bidder or (iii) A certified Public Accountant] certifying that such information/ documents are based on the audited accounts as the case may be
Note – II: SSimilarly, if the bidder happens to be a Group / Holding / Parent Company, the Bidder should submit the above documents / information of its own (i.e. exclusive of its subsidiaries) duly certified by any one of the authority mentioned in Note-I above certifying that these information / documents are based on the audited accounts, as the case may be.
Litigation History: The bidder should provide a statement giving details / information on any litigation or arbitration raised or arising out of contracts completed or under execution by it over the last five years. A consistent history of awards involving litigation against the Bidder may result in rejection of the Bid submitted
5.2 In case of JV bidders, the Bidder should accordingly also provide/ upload the Audited balance sheet and income statements for the last five years for all the Partners of JV.
6.0 LITIGATION HISTORY: Details of litigation History resulting from the contracts completed or under execution by the bidder over last five years.
Select whichever is applicable (If yes give the details as per below) : NO
Year Name of Client, cause of Litigation/Arbitration and matter of dispute Details of Contract & Date Judgment for or against the bidder Disputed Amount
We do not have any litigation History resulting from the contracts completed or under execution by us over last Seven years
6.0 Technical Credentials: List of work regarding past experience indicating the execution of similar work successfully, schedule time of completion and actual time of completion, the present status of projects in hand along with presently envisaged completion dates, qualification and experience of key personnel proposed for carrying out the subject work. List of available T & P and Manpower available with the bidder is also to be enclosed
6.1 Works in Hand
Details of Contract Value of Outstanding projects Tentative Completed date
6.2 List of Tools, Equipments & Plants
Sl. No. Name of Machine Nos
6.3 Qualification & Experience of key personal:
Sl. No. Designation Qualification Experience in Years
4 Additional Information
1 Details of works in hand(Use additional sheet if required and upload the same)
S.No Work Order Ref OrderValue ScheduledCompletion date Anticiated completion date Details of work % works completed as on date of submissionof bid
2 Maximum value of similar works executed in anyone financial year during last 07 financial years in Rs.
3 Litigationhistory Whether uploaded
Satement giving details / information on any litigation or arbitration raised or arising out of contracts completed or under execution by it over the last five years. Yes
Date: --2026 Printed Name :
Place:. Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment- 4
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Form of Certificate of Origin and Quality)
Bidder’s Name and Address (Authorised Person) : To :
Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore-560064
Sub. : Form of certificate of Origin and Eligibility - Reg
We certify that equipments and materials to be supplied are produced in [Name of countries], Eligible Source country Equipments & Materials produced in (Name of countries) Company incorporated & registered in [Name of countries]
We certify that our company is incorporated and registered in [Name of countries], Eligible Source country
Date: Printed Name :
Place:. Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment- 3
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(List of Special Maintenance tools & Tackles
Bidder’s Name and Address (Authorised Person) : To :
Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore-560064
We are furnishing below the list of special maintenance tools & tackles for various equipments under the subject package. The prices for these tools & tackles are included in our lumpsum bid price. We further confirm that the list of specical maintenance tools & tackles includes all the items specifically identified in your bidding documents as brought out below :-
Sl.No For Equipment Item description Unit Quantity o
Notwithstanding what is stated above, we further confirm that any additional speical maintenance tools & tackles required for the equipmenyts under this package shall be furnished by us at no extra cost to the employer.
Date: 00-Jan-00 0 Printed Name :
Place:. Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546)
[Commercial Deviations Schedule]
Sl. No. Vol./ Clause Ref/ Page No. As Specified in the specification Commercial Deviation & Variations/Exceptions
Date: Printed Name :
Place:. Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment- 5
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Bought Out & Sub contracted Items)
Bidder’s Name and Address (Authorised Person) : To :
Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore-560064
We hereby furnish the details of the items/Sub Assemblies, we propose to buy for the purpose of furnishing and installation of the subject package.
Sl.No Item description Quantity proposed to be bought out /Sub contracted Details of proposed sub contractor/Sub vendor
Name Nationality TRUE
We hereby declare that we would not subcontract the erection portion of the contract without prior approval of the employer.
We hereby furnish the details of the items/ sub-assemblies propose to supply from our own works (i.e as direct transactions)in addition to the supply the same from the same vendors (i.e bought out transactions) as detailed in the table given below:
Sl.No Item description Quantity proposed to be supplied Details of the plant from where supplies are proposed
Name of the plant Address
Date: Printed Name :
Place:. Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment- 5
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Items, Components, Raw materials, Services proposed to be sourced from Micro & Small enterprises)
Bidder’s Name and Address (Authorised Person) : To :
Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore-560064
1 We hereby furnish the details of the items, components, Raw materails, services proposed to buy/avail from Micro & small enterprises for the purpose of completion of works under the subject package
Sl.No Item description Quantity proposed to be bought /Sub contracted Name of the Micro & Small enterprises (MSEs)
Name Category (Micro or Small) TRUE
2 The above is a list of items we propose to procure from MSEs. However based on situations during the execution of contract the above list may undergo changes. We hereby confirm that the details regarding the actual procurement from MSE carried out by us , as per the format provided at Section- VI (Forms and procedures), Volume -I of the bidding documents, shall be submitted along with the bills for payments against supplies made /Works done during the execution of the contract.
Date: 00-Jan-00 0 Printed Name :
Place:. Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546)
[Commercial Deviations Schedule]
Sl. No. Vol./ Clause Ref/ Page No. As Specified in the specification Commercial Deviation & Variations/Exceptions
Date: Printed Name :
Place:. Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment- 6A
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(COMMERCIAL DEVIATIONS)
Bidder’s Name and Address (Authorised Person) : To :
Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore-560064
Sub. : Commercial Deviations for Package.
The following are the Commercial deviations and variations from and exceptions to the specifications and documents for the subject package. These deviations and variations are exhaustive. Except for these deviations, the entire work shall be performed as per your specifications and documents.
Sl. No. Volume/ Clause Ref/ Page No. As Specified in the specification Commercial Deviation & Variations to the specifications
Date: 00-Jan-00 0 Printed Name :
Place:. Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546)
[Commercial Deviations Schedule]
Sl. No. Vol./ Clause Ref/ Page No. As Specified in the specification Commercial Deviation & Variations/Exceptions
Date: Printed Name :
Place:. Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment- 6B
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(TECHNICAL DEVIATIONS)
Bidder’s Name and Address (Authorised Person) : To :
Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore-560064
Sub. : Technical Deviations for Package.
The following are the Technical deviations and variations from and exceptions to the specifications and documents for the subject package. These deviations and variations are exhaustive. Except for these deviations, the entire work shall be performed as per your specifications and documents.
Sl. No. Volume/ Clause Ref/ Page No. As Specified in the specification Technical Deviation & Variations to the specifications
Date: 00-Jan-00 Printed Name :
Place:. Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546)
[Commercial Deviations Schedule]
Sl. No. Vol./ Clause Ref/ Page No. As Specified in the specification Technical Deviation & Variations to the specifications
Date: Printed Name :
Place:. Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment- 6(C)
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
[ Deviations on important/critical conditions along with their withdrawal price]
Bidder’s Name and Address (Authorised Person) : To :
Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore-560064
The following are the deviations/variations/exceptions to the provisions of important/ critical conditions stipulated in bid documents. We undertake to execute the contract in line with the provisions of Bidding Documents in respect of above said clauses in case POWERGRID agrees to pay- us the withdrawal price indicated below against each such deviations/ variations/ exceptions.
Sl. No. Volume of Bidding document Section Clause No./ Page No. Statement of Deviations/ Variations/ Exceptions Withdrawal Price (in INR)
Date: 00-Jan-00 Printed Name :
Place:. Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546)
[ Deviations on important/critical conditions along with their withdrawal price]
Sl. No. Vol./ Section Clause No./ Page No. Statement of Deviations/Variations/Exceptions Withdrawal Price (in INR)
Date: 00-Jan-00 Printed Name :
Place:. Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment-6D
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
Bidder’s Name and Address (Authorised Person) : To :
Sr. General Manager(C&M)
Power Grid Corporation of India Ltd.,
Name : SR-II,RHQ
Address : Singanayakanahalli,Yelahanka
Bangalore-560064
Further, we hereby confirm that except as mentioned in the Attachment -6A (Commercial Deviations), Attachment 6B (Technical Deviations) and Attachment - 6C (Deviations on important/critical conditions along with their withdrawal price) thereof , forming part of our Techno commercial bid:
(i) there are no discrepencies/inconsistencies and deviations/omissions/reservations to the Bidding Documents, in the Second Envelope bid;
Date : Printed Name :
Place : Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment-7
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Details of Alternative Bid)
Bidder’s Name and Address (Authorised Person) : To :
Sr.General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore-560064
NO ALTERNATE BID
Date : Printed Name :
Place : Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment - 9
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Work Completion Schedule)
Bidder’s Name and Address (Authorised Person) : To :
Sr.General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore-560064
We hereby declare that Work Completion Schedule shall be followed by us as per the bidding documents in furnishing and installation of the subject Package i.e., WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor. for the period commencing from the effective date of Contract
Sl. No. Description of Work/ Activity Period in Months (from the effective date of LOA) - 12 Months
Commencement Completion
1 Detailed Engineering and drawing Submission
2 Procurement of equipment/Component/Assembly
4 Manufacturing
5 Shipment & Delivery
6 Establishment of Site office
7 Installation at site
8 Testing and commissining
9 Trial operation
Date : Printed Name :
Place : Designation :
Note : Bidders to enclose a detailed network covering all the activities to be undertaken for completion of the project indicating key dates for various milestones for each phase constituent-wise.
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment - 10
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Guarantee declaration)
Bidder’s Name and Address (Authorised Person) : To :
Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
We confirm that the equipments offered shall have minimum performance specified in the technical specification. We further guarantee the performance/Efficiency in response to the technical specification.
Date : 00-Jan-00 Printed Name :
Place : Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment - 10
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Information regarding Ex-employees of POWERGRID in our Organisation)
0 Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : 00-Jan-00 Printed Name :
Place : Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment - 10
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Information regarding Ex-employees of POWERGRID in our Organisation)
0 Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : 00-Jan-00 Printed Name :
Place : Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment - 11
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Information regarding Ex-employees of POWERGRID in our Organisation)
Bidder’s Name and Address (Authorised Person) : To :
Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment - 11
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Information regarding Ex-employees of POWERGRID in our Organisation)
0 Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment - 11
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Information regarding Ex-employees of POWERGRID in our Organisation)
0 Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
We hereby furnish the details of ex-employees of POWERGRID who had retired/ resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us:
Sl. No. Name of the person with designation in POWERGRID Date of Retirement/ resignation from POWERGRID Date of joining and designation in our organisation
Date : Printed Name :
Place : Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment- 12 12
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Price Adjustment Data)
PRICE VARIATION IS NOT APPLICABLE FOR THIS PACKAGE
Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Date : Printed Name : Singanayakanahalli,Yelahanka
Place : Designation :
We hereby Confirm, the prices are quoted in accordance to Price variation provisions of the bidding documents.
Sl. No. Name of Materials/Labour Name of the published index Value of index (30 days prior to date of opening of bids)
1 Supply & Placement of Reinforcement Steel
A High Speed Diesel coefficient Wholesale Price Index Number for ‘High Speed Diesel’ (Individual commodity) (monthly) (Base: 2004-05=100) as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
L Labour coefficient Indian Labour Bureau, Shimla, Govt. of India (monthly) (Base: 2001 = 100) (www.labourbureau.nic.in)
B Ferrous Metals coefficient Wholesale Price Index Number for ‘Ferrous Metals’ (Group Item) (monthly) (Base: 2004-05=100) as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
2 For Concreting
A High Speed Diesel, coefficient a = Wholesale Price Index Number for High Speed Diesel’ (Individual commodity) (monthly) (Base: 2004-05=100) as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
L Labour, coefficient l = Indian Labour Bureau, Shimla, Govt. of India (monthly) (Base: 2001 = 100) (www.labourbureau.nic.in)
B Cement & Lime, coefficient b = Wholesale Price Index Number for ‘Cement & Lime’ (Group Item) (monthly) (Base: 2004-05=100) as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
C Structural Clay Products coefficient Wholesale Price Index Number for ‘Structural Clay Products’ (Group Item) (monthly) (Base: 2004-05=100) as published by Office of Economic Advisor, Ministry of Commerce & Industry (www.eaindustry.nic.in).
The Bidders are required to indicate the value of indices for various components as of 30 days prior to the date of bid opening. In case bid opening date is extended after submission of bids because of any reason, indices as of 30 days prior to actual date of bid opening shall be considered for placement of award and for payment towards price adjustment.
Date : 00-Jan-00 Printed Name :
Place : Designation :
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Attachment-13
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Declaration regarding Social Accountability)
Bidder’s Name and Address (Authorised Person) : To :
Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore-560064
We conform that we stand committed to comply to all requirements of Social Accountability Standards i.e., SA8000 (latest Standard available at www.sa-intl.org) and maintain the necessary records.
Date : Printed Name :
Place : Designation :
Instruction for printing & submitting Integrity Pact
1. The requisite format of Integrity Pact is getting generated automatically and displayed here below.
2. Take print out of first page on a non-judicial stamp paper of Rs. 100/- and other seven pages on plain A4 size paper. Such two sets shall be prepared by the bidder.
3. All the pages of both the copies of the Integrity Pact shall be signed by the authorised representative of the bidder and duly stamped.
4 The format of integrity pact is attached below
5 Both the original copies shall be submitted by the bidder in the form of Hard Copy as part of the first envelope before due date & time of submission of the bid.
6 For further details bidders may please refer ITB Clause 9.3 (n).
Power Grid Corporation of India Limited
having its Registered Office at B-9, Qutab Institutional Area, Katwaria Sarai, New Delhi – 110016 hereinafter referred to as
having its Registered Office at
having its Registered Office at & and & respectively
hereinafter referred to as
"The Bidder/Contractor"
POWERGRID intends to award, under laid-down organisational procedures, contract(s) for WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 1 of 8
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor. Package and Specification Number SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) POWERGRID values full compliance with all relevant laws and regulations, and the principles of economical use of resources, and of fairness and transparency in its relations with its Bidders/ Contractors.
In order to achieve these goals, POWERGRID and the above named Bidder/Contractor enter into this agreement called 'Integrity Pact' which will form a part of the bid.
It is hereby agreed by and between the parties as unde r:
Section I - Commitments of POWERGRID
(1) POWERGRID commits itself to take all measures necessary to prevent corruption and to observe the following principles :
a) No employee of POWERGRID, personally or through family members, will in connection with the tender, or the execution of the contract, demand, take a promise for or accept, for him/herself or third person, any material or other benefit which he/she is not legally entitled to.
b) POWERGRID will, during the tender process treat all Bidder(s) with equity and fairness. POWERGRID will in particular, before and during the tender process, provide to all Bidder(s) the same information and will not provide to any Bidder(s) confidential/ additional information through which the Bidder(s) could obtain an advantage in relation to the tender process or the contract execution.
c) POWERGRID will exclude from evaluation of Bids its such employee(s) who has any personnel interest in the Companies/Agencies participating in the Bidding/Tendering process.
(2) If Chairman and Managing Director obtains information on the conduct of any employee of POWERGRID which is a criminal offence under the relevant Anti-Corruption Laws of India, or if there be a substantive suspicion in this regard, he will inform its Chief Vigilance Officer and in addition can initiate disciplinary actions under its Rules.
Section II - Commitments of the Bidder/Contractor
(1) The Bidder/Contractor commits himself to take all measures necessary to prevent corruption. He commits himself to observe the following principles during his participation in the tender process and during the contract execution :
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 2 of 8
a) The Bidder/Contractor will not, directly or through any other person or firm, offer, promise or give to POWERGRID, or to any of POWERGRID's employees involved in the tender process or the execution of the contract or to any third person any material or other benefit which he/she is not legally entitled to, in order to obtain in exchange an advantage during the tender process or the execution of the contract.
b) The Bidder/Contractor will not enter into any illegal agreement or understanding, whether formal or informal with other Bidders/Contractors. This applies in particular to prices, specifications, certifications, subsidiary contracts, submission or non-submission of bids or actions to restrict competitiveness or to introduce cartelization in the bidding process.
c) The Bidder/Contractor will not commit any criminal offence under the relevant Anti-corruption Laws of India; further, the Bidder/Contractor will not use for illegitimate purposes or for purposes of restrictive competition or personal gain, or pass on to others, any information provided by POWERGRID as part of the business relationship, regarding plans, technical proposals and business details, including information contained or transmitted electronically.
d) The Bidder/Contractor of foreign origin shall disclose the name and address of the Agents/representatives in India, if any, involved directly or indirectly in the Bidding. Similarly, the Bidder/Contractor of Indian Nationality shall furnish the name and address of the foreign principals, if any, involved directly or indirectly in the Bidding.
e) The Bidder/Contractor will, when presenting his bid, disclose any and all payments he has made, or committed to or intends to make to agents, brokers or any other intermediaries in connection with the award of the contract and/or with the execution of the contract.
f) The Bidder/Contractor will not misrepresent facts or furnish false/forged documents/informations in order to influence the bidding process or the execution of the contract to the detriment of POWERGRID.
(2) The Bidder/Contractor will not instigate third persons to commit offences outlined above or be an accessory to such offences.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 3 of 8
Section III- Disqualification from tender process and exclusion from future contracts
(1) If the Bidder, before contract award, has committed a serious transgression through a violation of Section II or in any other form such as to put his reliability or credibility as Bidder into question, POWERGRID may disqualify the Bidder from the tender process or terminate the contract, if already signed, for such reason.
(2) If the Bidder/Contractor has committed a serious transgression through a violation of Section II such as to put his reliability or credibility into question, POWERGRID may after following due procedures also exclude the Bidder/Contractor from future contract award processes. The imposition and duration of the exclusion will be determined by the severity of the transgression. The severity will be determined by the circumstances of the case, in particular the number of transgressions, the position of the transgressors within the company hierarchy of the Bidder/Contractor and the amount of the damage. The exclusion will be imposed for a minimum of 12 months and maximum of 3 years.
(3) If the Bidder/Contractor can prove that he has restored/recouped the damage caused by him and has installed a suitable corruption prevention system, POWERGRID may revoke the exclusion prematurely.
Section IV - Liability for violation of Integrity Pact
(1) If POWERGRID has disqualified the Bidder from the tender process prior to the award under Section III, POWERGRID may forfeit the Bid Guarantee under the Bid.
(2) If POWERGRID has terminated the contract under Section III, POWERGRID may forfeit the Contract Performance Guarantee of this contract besides resorting to other remedies under the contract.
Section V- Previous Transgression
(1) The Bidder shall declare in his Bid that no previous transgressions occurred in the last 3 years with any other Public Sector Undertaking or Government Department that could justify his exclusion from the tender process.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 4 of 8
(2) If the Bidder makes incorrect statement on this subject, he can be disqualified from the tender process or the contract, if already awarded, can be terminated for such reason.
Section VI - Equal treatment to all Bidders / Contractors
(1) POWERGRID will enter into agreements with identical conditions as this one with all Bidders.
(2) POWERGRID will disqualify from the tender process any bidder who does not sign this Pact or violate its provisions.
Section VII - Punitive Action against violating Bidders / Contractors
If POWERGRID obtains knowledge of conduct of a Bidder or a Contractor or his subcontractor or of an employee or a representative or an associate of a Bidder or Contractor or his Subcontractor which constitutes corruption, or if POWERGRID has substantive suspicion in this regard, POWERGRID will inform the Chief Vigilance Officer (CVO).
(*)Section VIII - Independent External Monitor/Monitors
(1) POWERGRID has appointed a panel of Independent External Monitors (IEMs) for this Pact with the approval of Central Vigilance Commission (CVC), Government of India, out of which one of the IEMs has been indicated in the NIT/IFB.
(2) The IEM is to review independently and objectively, whether and to what extent the parties comply with the obligations under this agreement. He has right of access to all project documentation. The IEM may examine any complaint received by him and submit a report to Chairman-cum-Managing Director, POWERGRID, at the earliest. He may also submit a report directly to the CVO and the CVC, in case of suspicion of serious irregularities attracting the provisions of the PC Act. However, for ensuring the desired transparency and objectivity in dealing with the complaints arising out of any tendering process, the matter shall be referred to the full panel of IEMs, who would examine the records, conduct the investigations and submit report to Chairman-cum-Managing Director, POWERGRID, giving joint findings.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 5 of 8
(3) The IEM is not subject to instructions by the representatives of the parties and performs his functions neutrally and independently. He reports to the Chairman-cum-Managing Director, POWERGRID.
(4) The Bidder(s)/Contractor(s) accepts that the IEM has the right to access without restriction to all documentation of POWERGRID related to this contract including that provided by the Contractor/Bidder. The Bidder/Contractor will also grant the IEM, upon his request and demonstration of a valid interest, unrestricted and unconditional access to his documentation. The same is applicable to Subcontractors. The IEM is under contractual obligation to treat the information and documents of the Bidder(s)/Contractor(s)/Subcontractor(s) with confidentiality.
(5) POWERGRID will provide to the IEM information as sought by him which could have an impact on the contractual relations between POWERGRID and the Bidder/Contractor related to this contract.
(6) As soon as the IEM notices, or believes to notice, a violation of this agreement, he will so inform the Chairman-cum-Managing Director, POWERGRID and request the Chairman-cum-Managing Director, POWERGRID to discontinue or take corrective action, or to take other relevant action. The IEM can in this regard submit non-binding recommendations. Beyond this, the IEM has no right to demand from the parties that they act in a specific manner, refrain from action or tolerate action. However, the IEM shall give an opportunity to POWERGRID and the Bidder/Contractor, as deemed fit, to present its case before making its recommendations to POWERGRID.
(7) The IEM will submit a written report to the Chairman-cum-Managing Director, POWERGRID within 8 to 10 weeks from the date of reference or intimation to him by POWERGRID and, should the occasion arise, submit proposals for correcting problematic situations.
(8) If the IEM has reported to the Chairman-cum-Managing Director, POWERGRID, a substantiated suspicion of an offence under relevant Anti-Corruption Laws of India, and the Chairman-cum-Managing Director, POWERGRID has not, within the reasonable time taken visible action to proceed against such offence or reported it to the CVO, the Monitor may also transmit this information directly to the CVC, Government of India.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 6 of 8
(9) The word ‘IEM’ would include both singular and plural.
(*) This Section shall be applicable for only those packages wherein the IEMs have been identified in Section – I : Invitation for Bids and/or Clause ITB 9.3 in Section – III: Bid Data Sheets of Conditions of Contract, Volume-I of the Bidding Documents.
Section IX - Pact Duration
This Pact begins when both parties have legally signed it. It expires for the Contractor after the closure of the contract and for all other Bidder's six month after the contract has been awarded.
Section X - Other Provisions
(1) This agreement is subject to Indian Law. Place of performance and jurisdiction is the establishment of POWERGRID. The Arbitration clause provided in the main tender document / contract shall not be applicable for any issue / dispute arising under Integrity Pact.
(2) Changes and supplements as well as termination notices need to be made in writing.
(3) If the Contractor is a partnership firm or a consortium or Joint Venture, this agreement must be signed by all partners, consortium members and Joint Venture partners.
(4) Nothing in this agreement shall affect the rights of the parties available under the General Conditions of Contract (GCC) and Special Conditions of Contract (SCC).
(5) Views expressed or suggestions/submissions made by the parties and the recommendations of the CVO/IEM# in respect of the violation of this agreement, shall not be relied on or introduced as evidence in the arbitral or judicial proceedings (arising out of the arbitral proceedings) by the parties in connection with the disputes/differences arising out of the subject contract.
# CVO shall be applicable for packages wherein IEM are not identified in Section IFB/BDS of Condition of Contract, Volume-I. IEM shall be applicable for packages wherein IEM are identified in Section IFB/BDS of Condition of Contract, Volume-I.
(Signature) (Signature)
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
Integrity Pact Page 7 of 8
(6) Should one or several provisions of this agreement turn out to be invalid, the remainder of this agreement remains valid. In this case, the parties will strive to come to an agreement to their original intentions.
Signature Signature
(For & On behalf of POWERGRID) (For & On behalf of Bidder/ Partner(s) of Joint Venture/ Contractor)
(Office Seal) (Office Seal)
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Witness 1 : Witness 1 :
Designation : Designation :
Integrity Pact Page 8 of 8
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Option for Interest Bearing Advance(s) (Initial Advance and/or Engineering Advance) and Information for E-payment, PF details and declaration regarding Micro/Small & Medium Enterprises)
Bidder’s Name and Address : Contracts & Materials
Name : Power Grid Corporation of India Ltd.,
Address : Southern Region Transmission System-II,
Near RTO Test Driving Track, Singanayakanahalli,
Yelahanka Hobli, Bangalore – 560 064
I We have read the provisions in the Bidding Documents regarding furnishing the option for advance payment. Accordingly, as per ITB Clause 9.3 as provided in Section BDS, Section III, Vol.-I of the Bidding Documents, we hereby confirm to opt the following:
Interest Bearing Advance(s)
(a) Supply Portion:
(i) Interest bearing Initial advance :
(ii) Interest Bearing Engineering Advance :
(b) Services Portion: Interest Bearing Initial Advance
Bidders to Select Yes/No for the advance requirements
II We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3.(a) Status – Company/others
[Declaration of Micro/ Small/ Medium Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
3.(b) Are you a MSE owned by SC/ST* entrepreneurs in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012 including subsequent amendment/notification/order (Indicate Yes/No)
3.(c) If 3(b) is ‘Yes’ please mention whether you are (Proprietary MSE/ Partnership MSE/ Private Limited Company) owned by SC/ST entrepreneurs
3.(d) Are you a MSE owned by women in line with Public Procurement Policy for Micro and Small Enterprises (MSEs) order 2012, Public Procurement Policy for Micro and Small Enterprises (MSEs) Amendment Order 2018 including subsequent amendment/notification/order (Indicate Yes/No)
4. Permanent Account (PAN) No.
5. GSTIN Numbers
I. GSTIN in the Sates/UT from where the supply of goods take place
Name of the States/UT GSTIN number
II. GSTIN in the States/UT where the supply for services take place (states where sites under the subject package is situated)
Name of the States/UT GSTIN number
6. PF Registration No. of the Company
7. PF Regional Office covered (with Address)
8. Name of Contact Person
9. Contact Details
10. Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Current Account
11. 9 digit MICR code printed at bottom in middle, next to cheque no.
12. IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
*The definition of MSEs owned by SC/ST is as given under:
a. In case of proprietary MSE, proprietor(s) shall be SC /ST.
b. In case of partnership MSE, the SC/ST partners shall be holding at least 51% shares in the unit.
c. In case of Private Limited companies, at least 51% share shall be held by SC/ST promoters.
Documentary evidence: Please provide scanned copy(ies) of the SC/ST certificate(s) issued by District Authority as applicable for SC/ST MSE category as per (a), (b) or (c) above.
Date : Printed Name :
Place : Designation :
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Additional Information)
Bidder’s Name and Address (Authorised Person) : To :
Sr. General Manager(C&M)
Name : Power Grid Corporation of India Ltd.,
Address : SR-II,RHQ
Singanayakanahalli,Yelahanka
Bangalore-560064
We have enclosed with our proposal the following additional information for the subject package:
S. No. Brief description of Information Ref. and Page No.
Date: 00-Jan-00 Printed Name :
Place:. Designation :
S. No. Brief description of Information Ref. and Page No.
Date: 00-Jan-00 Printed Name : 0
Place:. Designation : 0
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
(Declaration for tax exemptions, reductions, allowances or benefits)
Bidder’s Name and Address (Authorised Person) : To :
Name : Sr. General Manager(C&M)
Address : Power Grid Corporation of India Ltd.,
Dear Sirs, 1. We confirm that we are solely responsible for obtaining following tax exemptions, reductions, allowances or benefits in respect of supplies under the subject package, in case of award. We further confirm that we have considered the same in our bid thereby passing on the benefit to POWERGRID while quoting our prices. In case of our failure to receive such benefits, partly or fully, for any reason whatsoever, the Employer will not compensate us. 2. We are furnishing the following information required by the Employer for issue of requisite certificate if and as permitted in terms of the applicable Govt. of India policies/procedures (in case of award):
Applicable Act, Notification No. and Clause Ref. No. Sl. No. Description of item on which applicable Country of origin Remarks, if any
(The requirements listed above are as per current Notification of Govt. of India indicated above. These may be modified, if necessary, in terms of the Notifications.)
Date : Printed Name :
Place : Designation :
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
#REF! #REF! #REF!
23 Twenty Three
27 Twenty Seven
28 Twenty Eight
33 Thirty Three
37 Thirty Seven
38 Thirty Eight
73 Seventy Three
74 Seventy Four
75 Seventy Five
77 Seventy Seven
78 Seventy Eight
79 Seventy Nine
83 Eighty Three
87 Eighty Seven
88 Eighty Eight
93 Ninety Three
97 Ninety Seven
98 Ninety Eight
100 One Hundred
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) ATTACHMENT-19
WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
Information for E-payment, PF details and declaration regarding Micro/Small & Medium Enterprises)
Name : 0 Sr. General Manager(C&M)
Address : 0 Power Grid Corporation of India Ltd.,
0 Near RTO Test Drive Track, Singanayakanahally
0 Yelahanka, Bangalore - 560 064
I We are furnishing the following details of Statutory Registration Numbers and details of Bank for electronic payment.
1. Name of the Supplier/ Contractor in whose favour payment is to be made
2. Address with PIN Code and State
Registered Office:
Correspondence Address:
3. Status – Company/others
[Declaration of Micro/ Small Enterprise under Micro/ Small & Medium Enterprises Development Act 2006, if applicable]
UDYAM Registration No:
4. Permanent Account (PAN) No.
6. PF Registration No. of the Company
7. PF Regional Office covered (with Address)
8. Name of Contact Person
9. Telephone No(s)
10. Bank Details for Electronic Payment
Name of the Bank:
Address of Branch:
Type of Account:
Type of Account: Current Account 2
11. 9 digit MICR code printed at bottom in middle, next to cheque no.
12. IFSC (for RTGS)/NEFT Code (to be obtained from the Bank) Sample Cancelled Cheque to be enclosed
We hereby declare that the above information are true and correct and we agree that the payment on account of this Contract, in the event of award, be made in the above account maintained in the above mentioned Bank.
Date : 00-Jan-00 0 Printed Name : 0
Place : 0 Designation : 0
SR2/NT/W-AIS/DOM/C00/26/10293 (RFx No. 5002005546) Techno commercial bid 0
2 or More FALSE FALSE
BID PROPOSAL FORM (Techno commercial bid)
Bid Proposal Ref. No.
Sr. General Manager(C&M)
Power Grid Corporation of India Ltd.,
Singanayakanahalli,Yelahanka
Bangalore-560064
Name of Contract : WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor.
Dear Ladies and/or Gentlemen,
1.0 We, the undersigned Bidder, having read and examined in detail the specification and documents of the subject package including amendment, if any, do hereby propose for WC-4910: Bay upgradation works at Pugalur SS for Reconductoring of Pugalur-Madurai 400 kV D/C line with HTLS conductor and Bay upgradation works at Tirunelveli SS for Reconductoring of Tirunelveli-Udumalpet 400 kV D/C line with HTLS conductor. as detailed in the specification and the bidding documents for the subject package. EMD DETAIL FORM 0
Are you UDYAM/MSME Registered: NO
Select the Form of EMD : Bid securing declaration
2.0 BID GUARANTEE/BID SECURING DECLARATION 0
2.1 0 Name of Issuing Bank :
Amount of EMD/ Bank Guarantee :
2.2 If I/We fail to keep the tender open as aforesaid or make any modifications in the terms and conditions of the tender which are not acceptable to POWERGRID, I/we agree that the POWERGRID shall without prejudice to any other right or remedy, be at liberty to forfeit the said earnest money absolutely. Should this tender be accepted, I/we hereby agree to abide by and fulfill all the terms, conditions and provisions of the aforesaid documents.
2.3 If, after the tender is accepted and I/we fail to commence the execution of the works as provided in the conditions, I/we agree that the corporation shall without prejudice to any other right or remedy be at liberty to forfeit the said earnest money absolutely.
2.0 PRICES & VALIDITY :
2.1 We understand that all prices and price components stated in the bid shall remain firm and not subject to any price adjustment, in line with the bidding documents. All prices and other terms and conditions of this proposal are valid for a period of 180 (One hundred Eighty) days from the date of opening of the Envelope-I(Techno commercial bid). We further declare that prices stated in our proposal are in accordance with your bidding documents.
2.2 Further, we confirm that we have read all the provisions in the Invitation for Bid (IFB), Instructions to bidders (ITB), Conditions of Contract for Civil Works and that of Special Conditions of Contract (SCC) (inclusive of those regarding applicable taxes, duties and levies in relevant clauses), Technical specifications & other documents and have submitted the bid accordingly.
2.3 We do hereby confirm that our bid prices quoted in our Proposal include, all costs such as cost of necessary materials, their transportation to site, cost towards tools, equipment and machineries including cost of personnel that may be required for successful completion of the work/s as per the Technical Specifications, including cost of site arrangement, overheads, insurance, whatsoever, as stipulated in the bidding documents for the total scope of work/s and all applicable taxes, duties and levies for all transactions between us and our sub-contractors as well as for all transactions between us and POWERGRID. We understand that Owner shall not entertain any claim on account of any taxes, duties or other levies or any interest therein.
2.5 We declare that items left blank in the Schedules will be deemed to have been included in other items. The total for each schedule and the total of grand summary shall be deemed to be the total price for executing the facilities and sections thereof in complete accordance with the Contract, whether or not each individual item has been priced.
4.0 DEVIATIONS:
4.1 We declare that the Contract shall be executed strictly in accordance with the specifications and documents except for the variations and deviations, all of which have been detailed out exhaustively in the following schedules, irrespective of whatever has been stated to the contrary anywhere else in our proposal.
a) Schedule of Commercial Deviations
b) Schedule of Cost of withdrawal of Deviations
c) Schedule of Technical Deviations
4.2 We confirm that specified stipulation of following critical clauses are acceptable to us and no deviations/exceptions are taken on any account whatsoever in the following clauses:
[a] Bid Security/ Bid Securing declaration Clause No 12.0, ITB Volume-I
[b] Terms of Payment Clause No.8.0, Conditions of Contract (GCC) & Appendix-1 of forms & Procedures,Sec-VI, Volume-I
[c] Contract Performance Guarantee/Performance Security Clause No.9.3.1,Section GCC, Vol.-I & Clause 11 of SCC,Sec-V, Vol-I
[d] Liquidated Damages Clause No 50 of SCC, Volume-I
[e] Price & Price Basis As per appendix -2 of Forms and procedures
[f] Guarantee & Defect Liability Period Clause No. 22.2 of GCC & Cl.51 of SCC, Sec-V Volume -I
[g] Work schedule Clause No. 21.1 of GCC & Cl.49 of SCC, Sec-V Volume -I
4.3 In line with relevant Clauses in Bid documents, we have declared the withdrawal price in Attachment – 5A for the deviations taken against the Clauses mentioned above and we undertake to execute the contract inline with the provisions of these clauses in case POWERGRID agree to bear the withdrawal cost.
4.4 Further, we agree that additional conditions, deviations, if any found in the proposal documents other than those stated in deviation Schedules, save that pertaining to any rebates offered, shall not be given effect to.
5.0 WORK SCHEDULE:
5.1 If this proposal is accepted by you, we agree to arrange site visit, submit Engineering data, provide services and complete the entire work from time to time in accordance with schedules indicated in the proposal. We fully understand that the time schedule stipulated in the proposal is the essence of the contract, if awarded. The completion schedule of the various major key phases of the Package is indicated.
7.0 CONTRACT PERFORMANCE GUARANTEE:
7.1 We further agree that if our proposal is accepted we shall provide an irrevocable Contract Performance Guarantee, within 15 days from LOA of value equivalent to ten percent (10%) of the Contract Price valid upto the end of ninety (90) days after the end of the contract warranty period in the form of ......................................... (Please specify the form of Guarantee) ……………... in your favour and enter into a formal agreement with you within Fifteen (15) days from the date of issue of Letter of Award of Contract.
8.0 Information regarding Ex-employees of POWERGRID who had retired/resigned at the level of General Manager and above from POWERGRID and subsequently have been employed by us; any other information in addition to the information called for in the proposal sheets and checklist duly filled in is enclosed as per respective schedules/ attachments.
6.0 We hereby declare that only the persons or firms interested in this proposal as principal or principals are named herein and that no other persons or firms other than those mentioned herein have any interest in this proposal or in the Contract to be entered into, if we are awarded the contract, that this proposal is made without any connection with any other person, firm or party like-wise submitting a proposal and that this proposal is in all respects for and in good faith, without collusion or fraud.
Thanking you, we remain,
Yours faithfully,
For and on behalf of
Date : Printed Name :
Place : Designation :
In case of bid from a Joint Venture, name & designation of representative of JV partner is to be provided and Bid Form is also to be signed by him 1 Jan 2013
Other Partner -1 Other Partner -2 2 Feb 2014
Printed Name : Printed Name : 2 4 Apr 2016
Designation : Designation : 5 May 2017
Please provide additional information of the Bidder 8 Aug
Business Address : 9 Sep
Name of Principal Officer : 12 Dec
Address of Principal Officer : 13
Note: (i) Written power of Attorney of Signatories of bid to commit the Bidder must be enclosed with the bid. (ii) Bidders may note that no prescribed proforma has been enclosed for Attachment -2 i.e. Power of Attorney. (iii) Bidders may use their own proforma for furnishing the required information with the bid. 16 1 one 1 st 1 January
17 2 two 2 nd 2 February
18 3 three 3 rd 3 March
19 4 four 4 th 4 April
20 5 five 5 th 5 May
21 6 six 6 th 0 6 June
22 7 seven 7 th 1 7 July
23 8 eight 8 th January 8 August
24 9 nine 9 th 1900 9 September
25 10 ten 10 th 10 October
26 11 eleven 11 th 11 November
27 12 twelve 12 th 12 December
28 13 thirteen 13 th
29 14 fourteen 14 th
30 15 fifteen 15 th
31 16 sixteen 16 th
the receipt of which is hereby acknowledged, we the undersigned, offer to design, manufacture, test, deliver, install and commission (including carrying out Trial operation, Performance & Guarantee Test as per the provision of Technical Specification) the Facilities under the above-named package in full conformity with the said Bidding Documents. In accordance with ITB Clause 9.1 of the Bidding Documents, as per which the bid shall be submitted by the bidder under “Single Stage - Two Envelope” procedure of bidding. Accordingly, we hereby submit our Bid, in two envelopes i.e. First Envelope – Techno – Commercial Part & Second Envelope - Price Part (to be opened subsequently). 17 seventeen 17 th
Bank Draft 18 eighteen 18 th
Pay Order 19 nineteen 19 th
Banks certified Cheque Zero 20 twenty 20 th
Bank Guarantee #REF! 21 st
Applicable 23 th
Not Applicable 24 th
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
Price_schedule.xlsx
xlsx • 1.53 MB
01_Attachment-3(QR).docx
docx • 0.07 MB
02_Attachment-8-MAF.docx
docx • 0.03 MB
03_Attachment-14 (IP).docx
docx • 0.03 MB
04_Attachment-18_(SP).docx
docx • 0.05 MB
05_Attach-20_KMP Decl.docx
docx • 0.04 MB
06_Att-21-MII_revised.docx
docx • 0.04 MB
07_Attach 23- ERA Comp.docx
docx • 0.02 MB
08_Attach-24_Decl Events.docx
docx • 0.05 MB
09-Att-25-Affid-DMI-SP.docx
docx • 0.04 MB
10_Attach-26-DOE.docx
docx • 0.03 MB
11_Attach-27_BSD.docx
docx • 0.02 MB
12_Attach-28-UT HC.docx
docx • 0.03 MB
13_Attachment-29_CIPP.docx
docx • 0.02 MB
Bid Form-First Envelope.xlsx
xlsx • 0.90 MB
.DS_Store
ds_store • 0.01 MB
01__3.75 m wide bitumen ROAD.pdf
pdf • 0.44 MB
04__Details of cable trench and cable trench road crossings.pdf
pdf • 0.63 MB
06__ROAD CULVERT.pdf
pdf • 1.50 MB
10__Details of drain.pdf
pdf • 2.24 MB
_1.DS_Store
ds_store • 0.01 MB
03_EARTHMAT LAYOUT Tirunelveli.pdf
pdf • 8.55 MB
12_SAS Architecture Tirunelveli.pdf
pdf • 2.23 MB
Eartmat Layout Pugalur.pdf
pdf • 0.67 MB
GA Pugalur.pdf
pdf • 0.17 MB
GA TIRUNELVELI.pdf
pdf • 0.57 MB
SAS DRAWING Pugalur.pdf
pdf • 0.79 MB
SLD Pugalur.pdf
pdf • 0.27 MB
SLD TIRUNELVELI.pdf
pdf • 0.30 MB
18-TS-Telecommunication System-Rev 05.pdf
pdf • 7.09 MB
PLCC R5.pdf
pdf • 0.06 MB
Sec Proj PkC Rev 00.pdf
pdf • 0.30 MB
Specific Requirement with Annexures_Rev 10.pdf
pdf • 9.19 MB
sec- C R Rev 09.doc.pdf
pdf • 0.37 MB
Section-Sub-station Automation_Rev04.pdf
pdf • 0.98 MB
SFQP Civil Works AIS Bay Extn. Package.pdf
pdf • 3.26 MB
Section-Switchgear-CB_Rev11.pdf
pdf • 0.61 MB
Section-Switchgear-INST_rev12.pdf
pdf • 0.86 MB
Section-Switchgear-ISO_Rev13.pdf
pdf • 0.68 MB
Section-Switchgear-SA_Rev13.pdf
pdf • 0.87 MB
1.0 GTR Rev 15 .pdf
pdf • 7.12 MB
5.0 LT Switchgear R5.pdf
pdf • 0.47 MB
7.0 Power & Control Cable Rev R6.pdf
pdf • 0.26 MB
11.0 Section_Switchyard Erection_Rev.10.pdf
pdf • 5.99 MB
15.0 Civil TS Rev 0.pdf
pdf • 0.93 MB
16.0 Structure Rev 7.pdf
pdf • 0.30 MB
_2.DS_Store
ds_store • 0.01 MB
00_Cover Pages.pdf
pdf • 2.96 MB
01_Main Index_Vol-I.pdf
pdf • 0.11 MB
02-Section - I Invitation for bids.pdf
pdf • 0.27 MB
03A_Sec-1_BDS.pdf
pdf • 0.57 MB
03B-Annexure-A (BDS)_Vol-I-QR.pdf
pdf • 0.18 MB
03C-Annexure-B(BDS)_Vol-I-e-RA.pdf
pdf • 0.08 MB
03D-Annexure-C(BDS)_Vol-I-e-RA.pdf
pdf • 0.20 MB
03_Sec-I_ITB.pdf
pdf • 0.56 MB
04-Section - IV GCC -S&I Rev 3-DCB.pdf
pdf • 1.93 MB
05-Sec_I_SCC.pdf
pdf • 0.59 MB
05A-Appendix -I to SCC_Vol-I.pdf
pdf • 0.23 MB
05B-Appendix-II SCC_Vol-I.pdf
pdf • 0.62 MB
06-Forms-Procedures.pdf
pdf • 1.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].