Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.3 LAccepted-AOC | ₹9.3 L Quoted ₹9.8 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹10.7 L+₹84,135.96 (8.54%)Rejected-AOC 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | ₹10.7 L+₹84,135.96 (8.54%) | L2 | Rejected-AOC Other than lowest bider |
| 3 | L3₹11.6 L+₹1.8 L (17.8%)Rejected-AOC | ₹11.6 L+₹1.8 L (17.8%) | L3 | Rejected-AOC Other than lowest bider |
| 4 | L4₹12.5 L+₹2.7 L (27.2%)Rejected-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | ₹12.5 L+₹2.7 L (27.2%) | L4 | Rejected-AOC Other than lowest bider |
| 5 | L5₹13.4 L+₹3.5 L (35.7%)Rejected-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | ₹13.4 L+₹3.5 L (35.7%) | L5 | Rejected-AOC Other than lowest bider |
Tender Value
Refer Docs
Closing Date
26 Jul 2022, 6:00 pmClosed
CWE(AF) Chandigarh
HQ CWE(AF) Chandigarh PIN-160030
REPAIRS TO ELECTRICAL WIRING, ELECTRICAL FITTINGS, GEYSERS, FANS ETC AT AIR FORCE STATION HIGHGROUNDS
2022_MES_532504_1
CWE/AF CHD/CHD/T-10/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Chandigarh
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE(I) (AF) Highgrounds
Exempted
29 Aug 2022
21 Jun 2022
2 Aug 2022
21 Jun 2022
26 Jul 2022
6 Jul 2022
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including GI earth wire on batten or in PVC conduit or in MS Conduit including fixtures and fittings such as switches, ceiling roses, pendants, fan regulators, sockets etc, removing materials to store for keeping in safe custody for reuse or for credit (credit for above items shall be made as per conditions separately) and making good disturbed surface of walls, floors, etc., complete all as specified and directed.
Material and labour for point wiring with two single core multi stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed FRLS colour code cable of 1100volts grade drawn through and including non metalic rigid PVC conduit medium duty of suitable size with all standard fittings such as Tee junction, bends etc, concealed in wall/fixed on ceiling including M.S. sunken boxes of suitable size made of 1.6mm thick MS sheet duly painted with anticorrosive paint, for housing switches, fan regulators etc. with PVC cover sheet 3mm thick (Make : Hylam, Plaza, Havells, Kalinga) including 1.5Sqmm (nominal area) multi stranded copper conductor PVC insulated unsheathed FRLS colour code cable of 1100volts grade for earth continuity, as for one light/exhaust fan/bell point or fan point (through regulator), controlled by one switch, complete all as specified and directed. Note(s) : (i) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required. (ii). Switches and fan regulator etc., shall be measured and paid separately.
All as per item No 2 here-in-before but point wiring for one 5 Amps socket outlet point on independent board controlled by one single pole, one way switch, complete all as specified.
All as per item No 2 here-in-before but point wiring for one 5 Amps socket outlet point on the same board controlled by one single pole, one way switch, complete all as specified.
All as per item No 2 here-in-before but point wiring for one light point controlled by two single pole, two ways switch, complete all as specified.
All as per item No 2 here-in-before but point wiring using 2.5 sqmm wire as main wire & 2.5 Sqmm continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No. 2 here-in-before but point wiring using 4 sqmm wire as main wire & 4.0 sqmm wire as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
Material and labour for point wiring with two single core multi stranded copper conductor 1.5 Sqmm (nominal area) PVC insulated unsheathed FRLS colour code cable of 1100volts grade drawn through existing non metalic rigid PVC conduit with all standard fittings such as Tee junction, bends etc, concealed in wall/fixed on ceiling using existing M.S. sunken boxes for housing switches, fan regulators etc., with provision of PVC cover sheet 3 mm thick (Make : Hylam, Plaza, Havells, Kalinga) including 1.5 Sqmm (nominal area) multi stranded copper conductor PVC insulated unsheathed FRLS colour code cable of 1100volts grade for earth continuity, as for one light/exhaust fan/bell point or fan point (through regulator), controlled by one switch, making good to disturbed surface, complete all as specified and directed. Note(s) : (i) Switches and fan regulator etc., shall be measured and paid separately.
All as per item No 8 here-in-before but point wiring using 2.5 sqmm as main wire & 2.5 sqmm wire as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
All as per item No 8 here-in-before but point wiring using 4 sqmm wire as main wire & 4.0 Sqmm wire as continous earth wire, for one 15 Amps socket outlet point on independent board controlled by one single pole, one way switch complete all as specified.
Material and labour for point wiring PVC insulated unsheathed multistranded copper conductor FRLS cable using two single core 1.5 Sq.mm (nominal area) in and including PVC casing and caping, including fittings and accessories, one run of continuous single core copper cable of 1.5 Sq. mm connecting to common earth dolly, using suitable PVC box for mounting of switches sockets fan regulators etc. & making good to disturbed surface for the one light/ fan point controlled by one single pole, one way switch complete all as specified and directed.
All as per item No 11 here-in-before but point wiring for one 5 pin 5 Amp socket outlet on independent board complete all as specified.
All as per item No 11 here-in-before but point wiring for one 5 Amps socket outlet point on same board controlled by one single pole, one way switch, complete all as specified.
All as per item No 11 here-in-before but point wiring for 2.5 sqmm wire as main wire & 2.5 sqmm wire for earth continuity connected to common earth dolly for one 5 pin 5 Amp socket outlet on independent board, complete all as specified.
All as per item No 11 here-in-before but point wiring for 4 sqmm wire as main wire & 4.0 sqmm wire for earth continuity connected to common earth dolly for one 5 pin 5 Amp socket outlet on indipendent board, complete all as specified and directed.
Supply and fixing switch piano, flush type, single pole, one way, 6Amp, 230volts, complete all as specified and directed.
Supply and fixing bell push, flush type, 6 Amp, 230volts, complete all as specified and directed.
Supply and fixing switch piano, flush type, single pole, two way, 6 Amp, 230volts, complete all as specified and directed.
Supply and fixing switch piano, flush type, single pole, one way, 16Amp, 230volts, complete all as specified and directed.
Supply and fixing socket outlet, flush type, 2 in 1, multi purpose, 5 pin, 6Amps, 230volts, complete all as specified and directed.
Supply and fixing socket outlet, flush type, 2 in 1, multi purpose 6 pin, 6Amps & 16Amps, 230 volts, complete all as specified and directed.
Supply and fixing ceiling rose, surface bakelite, polycarbonate / PVC isolated body, 65mmx50mm, two to three terminals, (ISI marked), complete all as specified and directed.
Supply and fixing in replacement bell ding dong type, 5Amp, 230volts, 50 Hz (domestic pattern), complete all as specified and directed.
Supply and fixing fan regulator electronic, socket type, suitable for 1200 mm /1400mm sweep ceiling fan, fixed in repairs, with and including provision of flexible PVC insulated 1 sqmm copper conductor as required, complete all as specified and directed.
Supply and fixing in replacement factory made prewired LED box type CRCA powder coated batten fitting, 4 feet long, suitable for retofit LED tube 1x20 watt upto connection block and connecting with three core PVC insulated and PVC seathed flexible copper conductor cable of size 01 Sqmm from ceiling rose to connector block, complete all as specified and directed . MAKE- Havells Cat No REGALBATTEN8UPTO1X22WSSBSWH or equivalent in makes mentioned at Appx 'B'
Supply and fixing in replacement LED light fitting mirror type with high output diffuser, 2 feet, 10 watt 220 V AC decorative type with driver, holder and LED lamp, including connecting up with three core flexible copper conductor cable of suitable size complete. all as specified and directed. MAKE- Havells Cat No LHEXACP7IN1W010 or equivalent in makes mentioned at Appx 'B'
Supply and fixing in repair LED tube rod 20 watts (retrofit LED tube) energy saving, recess / surface mounted luminaire suitable for fixing in the batten fitting 1x18W to 22W, complete all as specified and directed Make : Havells cat NoPHOTONULTRA 1213T8SSTL20WLED865SPC or equivalent in makes mentioned at Appx 'B'
Supply and fixing in replacement wall mounted fittings with ABS housing and clear polycarbonate cover including LED bulb 15 watts complete and provision of flexible copper 3 core cable 0.5 Sqmm from connector/ ceiling rose to fitting all as specified and directed Make : Havell's /equivalent HPL code HPL81410(CW) or equivalent in makes mentioned at Appx 'B'
Supply and fixing in replacement LED luminaire 600 mm x 600 mm, 40 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing in replacement round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
Supply and fixing in replacement LED light fitting 1X10 W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed
Supply and fixing in replacement sheet metal enclosure, SPN, with a two pin socket and earth plug, with one MCB single pole, 240 Volts, 20 Amps, ‘B’ curve, 10 KA, complete all as specified and directed
Supply and fixing in replacement sheet metal enclosure (DB) single phase with neutral, 2 way, 240 volt without bus bar, IP 54 protection, including taking out old unserviceable complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement MCBs Distribution board sheet metal enclosures, SPN 415 Volts, 04 ways with 200 amps rated bus bar, double door, with IP 54 protection, complete all as specified and directed.
All as per item No. 34 here-in-before but DB 8 ways
All as per item No 34 here-in-before but DB 12 ways
Supply and fixing in replacement MCBs Distribution board sheet metal enclosures, TPN 415 Volts, 04 ways with 200 amps rated bus bar, double door, with IP 54 protection, complete all as specified and directed.
All as per item No.37 here-in-before but DB 8 ways.
Supply and fixing Load line TPN vertical distribution board 8 Way double door dust protected powder coated inclusive of busbar, neutral link, blanking plates and comprising of following incoming (i) MCCB TP 160 Amps 25 KA - 01 No, having IP-43 protection, complete all as specified and directed. Make-Legrand, (DX3/ SCHNEIDER- (ACTI-9)/ Seimens Betagard (10KA)/ Havells.
Supply and fixing MCCB, TP, 100 Amps, 415 Volt, having breaking capacity 10 KA, fixed thermal & fixed magnetic setting, Ics=100% of Icu including taking down old MCCB complete all as specified and directed.
Supply and fixing MCB 63 Amp, 415 Volt, TPN, breaking capacity 10 KA, 'C' curve, fixed in repairs, complete all as specified and directed.
Supply and fixing MCB 32/40 Amp, 415 Volt, TPN, breaking capacity 10 KA, 'C' curve, fixed in repairs, complete all as specified and directed.
Supply and fixing MCB 63 Amp, 415 Volt, TP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified and directed.
Supply and fixing MCB 40 Amp, 415 Volt, TP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified and directed.
Supply and fixing MCB 40 Amp, 415 Volt, SPN, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified and directed.
Supply and fixing MCB 6 to 32 Amp, 240 Volt, SP, breaking capacity 10 KA, 'B' curve, fixed in repairs, complete all as specified and directed.
Material and labour for Sub Main Wiring (in replacement) with two single core 2.5 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC casing & caping of suitable size with and including one run of continuous multi stranded copper conductor 2.5 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 2.5 Sqmm main cable + one run of 2.5 Sqmm cable for earth continuity and PVC casing & caping shall be measured as one unit/one Running Metre.
Material and labour for Sub Main Wiring (in replacement) with two single core 4 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in and including PVC casing & caping of suitable size with and including one run of continuous multi stranded copper conductor 4 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 4 Sqmm main cable + one run of 4 Sqmm cable for earth continuity and PVC casing & caping shall be measured as one unit/one Running Metre.
Material and labour for Sub Main Wiring (in replacement) with two single core 10 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in existing conduit with and including one run of continuous multi stranded copper conductor 10 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 10 Sqmm main cable + one run of 10 Sqmm cable for earth continuity and PVC casing & caping shall be measured as one unit/one Running Metre.
Material and labour for Sub Main Wiring (in replacement) with two single core 6 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in existing conduit with and including one run of continuous multi stranded copper conductor 6 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 6 Sqmm main cable + one run of 6 Sqmm cable for earth continuity and PVC casing & caping shall be measured as one unit/one Running Metre.
Material and labour for Sub Main Wiring (in replacement) with two single core 4 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in existing conduit with and including one run of continuous multi stranded copper conductor 4 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 4 Sqmm main cable + one run of 4 Sqmm cable for earth continuity and PVC casing & caping shall be measured as one unit/one Running Metre.
Material and labour for Sub Main Wiring (in replacement) with two single core 2.5 Sqmm (nominal area) multi stranded copper conductor FRLS PVC insulated and unsheathed colour code cables, drawn in existing conduit with and including one run of continuous multi stranded copper conductor 2.5 Sqmm (nominal area) FRLS PVC insulated and unsheathed colour code cable for earth continuity, 1100 volts grade , complete all as specified and directed. Note(s): (i) Two runs of 2.5 Sqmm main cable + one run of 2.5 Sqmm cable for earth continuity and PVC casing & caping shall be measured as one unit/one Running Metre.
Supply and fixing PVC non metallic rigid concealed conduit 32 mm, medium grade inclusive of junctions, bends, elbows, tees, reducers, bell mouth tube ends fixing accessories such as couplers lock nuts, saddles, pipe hooks etc including cutting chases for conduits and taking down existing batten/ conduit and making good the surface as per existing specifications, complete all as specified and directed.
All as per item No. 53 here-in-before but 25 mm dia conduit.
All as per item No. 53 here-in-before but 20mm dia conduit
Material and labour for earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground vertically (depth of pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5m below normal ground level, earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron wire 4mm dia (upto body of equipment) by means of nuts, bolts, check nuts & GI washers, connected to main switch board or main control board or test point, protected by galvanized iron pipe light grade 40mm dia bore, and watering pipe 20mm dia bore GI medium grade with funnel & wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 & RCC cover, all as shown in electrical plate No 3 of MES Schedule Part-I (2009), testing on completion, complete including dismantling of existing earthing all as specified and directed. Note(s) :- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with XPM not less than 4Kg/Sqm. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include GI strip and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt.
Taking up / down water heater (Geyser) of capacity 50/35/25 ltrs operating on 230 volts AC electric supply, in any position and of any make, after disconnecting all electric connections and hot & cold water connection, including transportation to contractor 's workshop for repair and vice - versa, painting / numbering ( if necessary) after repairing, general cleaning/overhauling, cleaning and discaling the tank and assembly with suitable detergent and making the geyser fully serviceable and fixing back in same location / position or new location as directed, complete all as specified and directed. Note :- (a) Replacement of any unserviceable part required for making the geyser serviceable will be measured and paid seperatelly under "supply only" and nothing extra shall be payable on this account.
Supply only stainless steel inner tank suitable for 25 ltrs capacity Geyser of any make / shape /any type of holes for fixing geyser assembly, complete all as specified and directed.
All as per item No 58 here-in-before but for 35 ltrs capacity Geyser.
All as per item No 58 here-in-before but for 50 ltrs capacity Geyser.
Supply only bottom base assembly of copper 9/8 holes type suitable for 35/25 ltrs capacity geyser, complete all as specified and directed.
All as per item No 61 here-in- before but for 50 ltrs capacity geyser, complete all as specified and directed. .
Supply only Heating element 1000/1500/2000 watts capacity of any shape /type with rubber gasket, complete all as specified and directed. Make :- Ditz, Dass pass
Supply only Thermostat for geyser suitable to adjust the temperature from 0º C to 80º C, complete all as specified and directed. Make :- Ditz, Dass Pass
Supply only Glass wool of good quality as approved, complete all as specified and directed.
Supply only Neon indicator lamp for geyser of any shape / size / colour, complete all as specified and directed
Supply only PVC insulated, sheathed 3 core flexible cable of size 2.5 Sqmm, complete all as specified and directed.
Supply only Safety plug any type for geyser, complete all as specified and directed..
Supply only non return valve 15 mm bore cast copper alloy suitable for geyser, complete all as specified and as directed
Supply only Rubber gasket of thickness 5 mm for geyser assembly with 08 holes / 09 holes, complete all as specified and as directed.
Supply only bottom inspection cover plate in two pieces with suitable openings for indicator lamps, power cable entry with rubber washer etc, gauge of plate not less than 18 SWG for 25/35/50 Ltrs capacity geysers of any make/ shape, complete all as specified and as directed.
Supply only 3 pin plug top 15 Amps, bakelite suitable for 230/240 volts AC supply, complete all as specified and as directed.
Supply only GI nut bolts and washers (not exceeding the size 150 mm x 12mm) of existing size of geyser spare parts, complete all as specified and as directed.
Supply only outer MS shell complete including top and bottom covers suitable for 25 Ltrs capacity geyser of any make, shape & size as per existing but gauge of sheet not less than 22 SWG, complete all as specified and as directed.
Supply only PVC connection 15 mm bore 450 mm long in any position with both end brass nut with inner threading and washer suitable for cold water connection, complete all as specified and as directed.
Supply only CPVC connection 15 mm bore 450 mm long in any position with both end brass nut with inner threading and washer suitable for hot water connection, complete all as specified and as directed.
Taking down, re-installation at new location as directed and testing storage type water heaters (Geyser) 25 Ltrs capacity operated on single phase AC electric supply, connection etc. including making good to the distrubed surface, complete all as specified and directed.
Disconnecting & taking down complete ceiling fan of any make 1200 mm / 1400 mm sweep with blade from fan hook/ fan box, transporting to local workshop , opening, cutting and taking out complete copper winding, cleaning with kerosene oil /diesel/ turpintine oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge in number of turns as recommended by the respective manufactures, varnishing and heating the winding including providing paper insulation (cuff/strip type) replacing u/s paper insulation (cuff / strip type), replacing u/s spare parts (bush, bearing, shackle, insulator, canopy, nuts , bolts, earthing , screw, upper socket, CI block , quarter /split pin (top & bottom) , lock nut, capacitor etc) fixing the stator in rotor, properly aligned and reassembling, ensuring right DOR, speedy and noiseless running and connecting cable and refixing at site or deposited in MES store as directed, complete all as specified and directed. Note: Bush, bearing, capacitor, canopy, shackle insulator with nuts, bolts and sockets shall be measured and paid for separately.
Supply only capacitor 2.50 MFD, 240 Volt AC, 50 Hz plastic body powder filled type complete all as directed.
Supply only capacitor 3.15 MFD, 240 Volt AC, 50 Hz plastic body powder filled type complete all as directed.
Supply only MS fan clamps with rubber real including nuts and bolts, split pin suitable for ceiling fan 1200 / 1400 mm sweep complete all as directed.
Supply only bearing suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed.
Supply only bush suitable for 1200 / 1400 mm sweep ceiling fan complete all as specified and directed.
Supply only PVC Canopy suitable for ceiling fan of 1200 / 1400 mm sweep set of two complete all as directed.
Supply only PVC insulated flexible 3 core, 1 sqmm size copper conductor cable including taking out the old unserviceable PVC flexible wire, complete all as specified and directed.
Supply & fixing Mild Steel Down Rod of suitable dia, 45 cm long white or coloured, compatible to existing ceiling fans of 1200 mm or 1400 mm sweep including taking out old unserviceable down rod from the fan, complete all as specified and as directed. Note:- Down-Rod shall be of make of existing fan or as approved by the GE.
Disconnecting and taking down ceiling fan of any sweep for carrying out overhauling such as cleaning , oiling, lubricating, greasing etc and replacement of minor parts such as washer, split pins/ blade screw etc and defective parts, if any, and refixing the ceiling fan fan on same location and connecting it properly and testing for noiseless running to the entire satisfaction of Engineer-in-charge. Note : (i). Defective parts required to be replaced shall be measured and paid for separately as supply only. (ii). Cost of the minor parts i.e. washer, split pins/ blade screw etc deemed to be included in unit rate & nothing extra shall be payable on this account.
Material and Labour for painting ceiling fans 1200/1400 mm sweep after taking down, with synthetic enamel paint by spraying, including filling cavities with fillter after cleaning all dust etc, re-writing the MES number in black paint in appropriate size and shape and refixing the same in position after painting, complete all as specified and directed.
Disconnecting & taking down (burnt) exhaust fan of any make 300 mm sweep, transporting to local workshop, opening, cutting and taking out complete copper winding, cleaning with kerosene oil / diesel/ turpintine oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge as recommended by the respective manufacturer, varnishing and heating the winding including providing paper insulation (cuff /strip type), replacing u/s spare parts (bush, bearing, capacitor etc), fixing the stator in rotor, properly aligned and reassembling ensuring right DOR, speedy and noiseless running and refixing at site or deposited in MES store as directed, complete all as specified and directed. Note: Bush, bearing, capacitor etc shall be measured and paid for separately.
All as per serial item No. 89 here-in-before but 450 mm sweep.
Supply and fixing in repair capacitor 4 MFD, 240 Volt AC, 50 Hz plastic body powder filled type for exhaust fan of 300/400mm sweep complete all as directed.
Disconnecting and taking down exhaust fan of any sweep for carrying out overhauling such as cleaning ,oiling, lubricating, greasing etc and replacement of defective parts, if any, and refixing the exhaust fan in same location and connecting it properly and testing for noiseless running to the entire satisfaction of Engineer-in-charge. Note : (i). Defective parts required to be replaced shall be measured and paid for separately as supply only. (ii). Cost of the minor parts i.e. washer, split pins/ blade screw etc shall be deemed to be included in unit rate & nothing shall be paid on this account.
Supply only bearing suitable for 300 / 400/ 450 mm sweep Exhaust fan complete all as specified and directed.
Material and labour for spray painting of Exhaust fan with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape complete all as directed. (Bush, bearing, capacitor, canopy, shackle insulator with nuts, bolts, sockets etc will be measured and paid separately).
Collecting unserviceable (burnt) table / cabin fan of any make and sweep up to 450 mm from MES store, transporting to local workshop, opening, cutting and taking out complete copper winding, cleaning with kerosene oil / diesel / turpintine oil and dried out, rewinding with new super enamelled copper wire of suitable size and gauge as recommended by the respective manufacturer, varnishing and heating the winding including providing paper insulation (cuff / strip type), replacing unserviceable spare parts (bush, bearing, capacitor etc), fixing the stator in rotor, properly aligned and reassembling ensuring right DOR, speedy and noiseless running and depositing in MES store, complete all as specified and directed.
Supply and fixing in replacement electronic energy meter with LCD display 10-60 A Cat Part No WM101BC7DLO of L& T or its equilant in the makes mentioned at Appx 'B' Note : Old meter shall be deposited in MES Store.
Supply and fixing in replacement electronic energy meter with LCD display 5-30A Cat Part No WM101BC5DL0 of L& T or its equilant in the makes mentioned at Appx 'B' Note : Old meter shall be deposited in MES Store.
Atternding comptaints of internal elect supply, including locating and rectification of fault and ensuring the compete serviceablity with replacement of defective/unserviceable components such as switches , sockets, lamp holder, ceiling rose, tube rod, LED, CFL, Tube light fitting, DBs, MCBs, main switches, service wires/cables etc and other accessories and per site requirement . Items required for replacement will be issued from MES store yard free for fixing Notes :- (a) Rates shall be deemed to include taking down and refixing related item. (b) Any Nos of complaints attended at one place/one qtr under one job card shall be considered as one job. (c) Emergent compaint shall be attended within 02 Hours. (d) Contractor shall employ one team consisting of one electrician ITI passed and one helper to attend the complaints. (e) Contractor or his representative will report to JE E/M daily at 0900 Hrs on all working days at the complaint cell and collect the compaints slips. After completion of job all complaints slips shall be deposited back to complaint cell by 1700 Hrs. (f) Any T&P required for rectification of complaints shalll be provided by the contractor. The cost of T&P shall be deemed to be included in quoted rate.
Note: The Total amount shall subject to adjustment of credit of Rs. 55,574.50 for old Materials as per Schedule of Credit.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .