Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹32.1 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹32.7 L+₹17.5 L (115.0%)Rejected-Finance | 2 | Rejected-Finance Not Lowest |
Tender Value
₹36.2 L
EMD Value
₹72,460
Closing Date
11 Dec 2020, 6:00 pmClosed
Garrison Engineer Abohar
Garrison Engineer Abohar Pin-152123
SPECIAL REPAIRS TO BLDG NO T-345 AND T-346 (ORs OTM) AND OTHER SANCTIONED WORKS AT MIL STN FAZILKA
2020_MES_388749_2
GE ABH-38/20-21
Open Tender
Civil Works
Item Rate
180 days
Fazilka Mil Stn
MES Registered Contractor enlisted in class E Category a (i) having deposited standing security of Rs 50000 with departments. Contractors not registered in MES should meet the MES enlistment criteria corresponding to appropriate class and category
5 documents required · 5 mandatory
₹500
Garrison Engineer Abohar
₹72,460
Yes
12 Jan 2021
27 Nov 2020
14 Dec 2020
27 Nov 2020
11 Dec 2020
28 Nov 2020
Amount
SCHEDULE 'A' SECTION I (B&R Portion)
Desmantling plain coraugated steel sheeting any guage, thickness including nanital or similar pattern roof covering.
Taking down chowkats or frame with shutters(without taking off shutters from the frame not exceeding 1.50 sqm each & removing to store all as specified.
Taking down chowkats with shutters (without taking off shutters from the frame exceeding 1.50 sqm each but not exceeding 4 sqm) removing to store
S&F PVC door frame of size 50x47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and designs
Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F stainless steel handle 125 mm long
S&F Stainless steel barrel tower bolt of extended section and fixed 150 mm long
S&F 100mm long butt hinges Stainless steel hinges pin, anodised and fixed
S & F pressed steel door frames with one or more rebates including necessary fixing lungs hinges lock strike plate etc complete all as specified size of frame 125 x 60mm all as specified and directed by Engineer - in - Charge .
M&L Cement concrete 1:3:6 type B–1 filling of pressed steel frame and hold fast blocks etc all as specified and directed by Engineer - in - Charge.
S & F Flush shutters, 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides as per SSR Part – I all as specified.
S&F 35mm thick 2nd class hard wood glazed Skelton shutters open rebated and prepare to receive glass gauges etc without sash bars edges of gramng plain chamfered or rounded fluted without and mixed beads for securing gases etc size of chambers as specified in SSR Part I sector 8-20 (a) fitted to chowkat.
S&F stainless steel barrel tower bolt 200mm long
S&F stainless steel pressed handles oval type 150mm size
S&F Stainless steel sliding door bolt 300 mm long plate type with bright bolt not less than12mm dia.
S&F in repair MS 300mm ordinary rat tail rod pattern springs including roller and roller plate complete.
S & F in repair steel window 1.25 mm thick Box type (primer coated) ERW hollow P section of size 60 mm x 25 mm single rebated comprises gauged and glazed both skelton shutter ERW Section 50 mm x 20 mm and 1 mm thick with two open able leaf consisting two Nos of sash bars of flat iron 12 mm x 3 mm complete welded to frame with one vertical mullion of ERW box type T section of size 60 mm x 25 mm and 1.25 mm thick including cutting holes and making good dismantled portion in PCC (1:2:4) type B-1 four Nos for each window including following fitting welded to the frame shutter : (a) Hold fast 150 mm long of 12 mm x 3 mm made to shape - 04 Nos per window. (b) Handle of Z section 20 mm x 25 mm, 100 mm long 1 Nos per leaf. (c) MS tower bolt 150 mm long - 2 Nos per leaf. (d) MS pintol hings of size 100 mm x 14 mm - 2 Nos per leaf. (e) Z section 20 mm x 25 mm x 100 mm long stopper per leaf complete all as specified and directed by Engineer-in-Charge. Note : Wire mesh, glass and painting shall be measured & paid seperately under appropriate item(s) of BOQ.
Supply & fixing in repair steel ventilators fixed type 1.25mm thick Box type (Primer coat) ERW hollow P dection of size 60 mm x 25 mm single rebated optional full glass or wire mesh. Note :Glass and painting shall be measured & paid seperately under appropriate items & Mesh also.
S&F in Guard bar square bars with (primer coated ) with 25 mm x 3 mm thick MS Flat all around the frame of windlow / ventilator. Note :Painting shall be measured & paid seperately under appropriate items & Mesh also.
S&F galvanized mild steel wire cloth 0.56mm nominal dia of wire and average width or aperture 1.18mm
S&F sheet glass 3mm thick ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 sqm in each pane
M&L preparing surface of wood and wood based surface new on any description not other wise described over 10cm with or grith and applying two coat of synthetic enamel paint over a coat of pink primer .
M&L preparation of new steel surface over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer.
Taking down cement or cement lime plaster from brick walls etc including raking out joints, hacking for key scrubbing down with water etc.
M & L for rendering 15mm thik on fair faces of brick work in cement mortar 1:6 finished even & smooth without using extra cement.
M & L for rendering 15mm thik on fair faces of brick work in cement mortar 1:4 finished even & smooth without using extra cement.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L glazed ceramic tiles 450x 250x 7mm/ 400X 300X 7mm colour tiles on walls etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the work over 10 mm rendering in CM 1:4.all as directed by Engineer-in-Charge.
M&L Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry to match the work using colour tiles over screed bed on bedding layer of mortar 15mm thick is CM 1:6.all as directed by Engineer-in-Charge.
M&L 50mm thick PCC 1:3:6 type C1 using 40 mm graded stone aggregate as in plinth protection, surface finished even smooth without using extra cement.
Demolation of brick wk built in cement mortar
Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:6
M&L brick work with fly ash modular bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6
Preparation of newly plastered surface of wall and applying two coats of cement base paint.
M & L Preparation of newly plastered surfaces by applying two coats of interior grade wall putty and making it smooth with sand paper by mechanical method i.e. with hand electric grinder then applying two coats of oil bound distemper over one coat of cement primer including all as specified by mechanical method i.e. spray gun all as specified and directed by Engineer-in-charge.
Dismantling water tanks and removing to store of 500 ltr capacity
S & F rotational moulded polythene three layered white coloured water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 500 Litres all as specified.Make -
S & F Vitreous china white OVAL wash basin of size 550 x 440 mm including brackets, waste pipe and waste fitting 40 mm brass chromium plated and waste pipe and 15 mm dia PVC connection with brass nuts as in repairs complete all as specified and as directed.
S&F 20mm Ball brass valves, high pressure, with polytheene float and flynut complete, screwed for iron pipe orr brass ferrule and fixed.
S&F in repaire PVC low level flushing system 10 Ltr capacity with flush pipe complete as approved by Eng-in charge.
Vitreous china squatting pan, Orissa Pattern size 580mm x 440 white with integral foot rest and ‘P’ or ‘S’ trap , front or back inlet but excluding flushing cistern and flush pipe including placing in position and embedded lean/lime concrete bedding,
S&F grating square 150mm dize of PTMT (minimum weight 100 gms)
S&F PVC waste pipe 32mm dia & 90 cm long
S&F PVC connection both side brass unions internal for size 15mm dia and 450mm long all as specified.
S&F in repair bib taps cast copper alloy screwed down crutch or buttefly handle screwed both ends for iron pipe brass ferrrule of size 15mm bore. Make-luster/BIR/ Leader (duly ISI marked and conf to relevant IS)
S&F in repair stop cock cast copper alloy screwed down, high pressure, with crutch of butterfly handle screwed both ends to iron pipe of size 15mm. Make Luster/BIR/Leader. (duly engrave ISI marked and conforming to relevant IS)
Taking up or down steel tubing of 15 mm bore and connections, including cleaning for re-fixing or removal to store
Taking up or down steel tubing of 20 mm bore and connections, including cleaning for re-fixing or removal to store
Supply & fixing mild steel tubes of size 15mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified.
Supply & fixing mild steel tubes of size 20 mm bore (medium grade) galvanised with all fittingsand fixed complete to wall all as specified.
S & F in repairs for brass chromium plated shower rose 125 mm size with swivel joint including fixing to 15 mm dia steel pipe or union.
S&F in repair towel rail 20mm dia, D type 60cm long between flanges brass bran chromium plated. Make -hindware. Esser etc equialant.
S & F of framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel')
M & L for roof trusses (Framed) Trussed, purlines, crane gantries, rail and fasternings and heavy bracket framing ( Beam, tee, angle, chanle or flat sec) including distance piece., cleats etc Fe - 410 W (Gde-E-250) A quaility all as specified and directed.
S & F mild steel screw bolts (machine made) 11 to 15mm dia with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long
S & F of 4 mm dia GI wire fitted with nut and bolt complete.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in loose / soft soil.
M & L 75mm thick PCC 1:4:8 , type D- 2, using 40mm graded aggregate as in sub base all as specified and as directed.
S&F machine pressed precast concrete interlocking paver block with grey cement & no pigment, any shape and size confirming to IS 15658-2006 of 80mm thick M-40 grade including and over 25mm thick sand cushion.
M & L PCC 1:2:4, type B-1 , using 20mm graded stone aggregate as in kerbs or mud stops, rounded or chamfered on edges and similar work all as specified and as directed.
S&F in repairs drapry curtain rod 25mm dia, fancy type, fabricated out of mild steel sheet not less than 20 guage, including brackets and pair of decorated end knobs (finials), stop roller etc, pretreated powder coated natural color complete all as specified and directed by Engineer-in-Charge.
Desmentling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets
Suspended false ceiling system using E grid size 600mm x 600mm with and including G.I. frame work of main runners 38mm x 24mm , cross Tee 28 mm x 24 mm and wall angle 24 mm x 24 mm hot diped galvanized steel with zinc coating not less than 120gm/sqm using 9.50 mm thick high tile front side PVC and back side foil paper pressure stream cured fiber cement primered disigner board ISI marked IS- 14862-2000 to be placed in grid existing purline to roof with butterfly clip completed all as specified and directed.Note invoice from company authorised dealer shall be sumitted with material by contractor along with dealership certificate . certified of genuineness from the manufacture shall also be submitted by the contrctor before getting the material paased from the department.
M&L in repair 18-20mm thick machine cut kota stone slab (table rubbed and polished) as in flooring laid over and including 15 mm thick screed bed or bedding layer in CM (1:4), set and jointed with grey cement slurry mixed with pigment to match the shade of slab including cutting, rubbing, grinding and mirror polishing upto desired satisfaction of Engr In Charge complete all as specified and directed by Engineer - in - Charge.
Excavation in post holes each n. exc. 0.50Cum, getting out in soft/loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc. 25cm, watering and removing surplus soil to a distance n. exc. 50m and making good surface.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation of cols, bdy pillars, posts, struts, etc. filling and mass concrete complete all as specified and shown on drawing.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundations etc or manholes, cesspits, pipes and cables etc. not exc 10 Sqm on plan and getting out in soft / loose soil all as specified and directed by Engineer - in - Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers of soft / loose soil not exceeding 25cm thick all as specified and directed by Engineer - in - Charge.
Removal of excavated material to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed by Engineer - in - Charge.
M&L Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation, filling and mass concrete all as specified and directed by Engineer - in - Charge
M & L brick work with sub class ‘B’ old size burnt bricks straight or curved on plan exceeding 6.0m mean radius built in cement mortar 1:6 all as specified and directed by Engineer – in – Charge.
M & L pre-cast RCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in landing, chajjas, shelves, cover slabs and similar articles of any thickness, size or shape including necessary from work, finishing the concrete surfaces fair and even in cement mortar and setting in cement Mortar 1:4 complete all as specified and directed by Engineer - in - Charge.
M&L Cement concrete 1:2:4 type B–1 using 20mm graded crushed stone aggregate as in surface channels and drains etc including use of necessary form work all as specified and directed by Engineer - in - Charge.
Reinforced concrete pipes 150mm bore class NP- 2, laid and jointed complete with collars, all as specified and directed by Engineer - in - Charge.
Supply only liquid waterproofing compound all as specified and directed by Engineer - in - Charge.
M & L damp proof course in cement concrete 1:2:4 type B0, 40mm thick to horizontal or vertical surfaces including necessary form work all as specified and directed by Engineer - in - Charge .
M & L cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in lintels up to 1.5 m clear span, seismic and other similar bands, benching, coping, bed blocks, apex stones and kerbs etc including use of necessary form work all as specified and directed by Engineer - in - Charge .
M & L mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, hooking ends and binding with MS wire (annealed) not less than 0.90mm dia all as specified and directed by Engineer - in - Charge .
All as per Srl item No. 82 here in before but 5mm and over for as in stirrups, spacers and binders all as specified and directed by Engineer - in - Charge.
M & L form work to soffits of suspended slabs such as roof slab and similar work not exceeding 200mm thick for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge .
M & L form work to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge.
M & L RCC 1:1½ :3, (nominal mix), Type A-1 using 20mm graded stone aggregates for slabs supported on walls, beams, columns and in shelves, the like all as specified and directed by Engineer - in - Charge .
M & L 40 mm thick Cement Concrete 1:2:4 type B–1 using 20mm graded stone aggregates flooring finished even and smooth without using extra cement all as specified and directed by Engineer - in – Charge .
M&L for Hardcore of gauge n exc. 63 mm of broken stone, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface all as specified and directed by Engineer - in - Charge.
M & L three coats of white wash including preparing new plastered or unplastered surfaces of ceiling complete all as specified and directed by Engineer - in - Charge.
M & L three coats of white wash including preparing new plastered or unplastered surfaces of walls complete all as specified and directed by Engineer - in - Charge.
S & F mild steel as in framed work as in doors or gates of angles or other section with gusset plates, rails, braces etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive for steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed by Engineer - in - Charge.
S&F anodized aluminium frame with Powder Coating (minimum thickness of powder coating 50 micron) for doors, windows, ventilators, partitions etc., with one or more rebates including joining cleat for fixing etc complete all as specified and as directed by Engineer-in-Charge.
S&F Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed by Engineer-in-Charge.
S & F framed work such as grills, grating, etc., with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; frame work for water tanks and similar work conforming to Fe-290 Gde E-165 all as specified and directed by Engineer - in - Charge.
S & F 4mm thick sheet glass ordinary quality and glazing with oil putty in square not exceeding 0.50 sqm in each pane all as specified and directed by Engineer - in - Charge .
M & L granite work (of any type) 18 to 20mm thick machine cut as in steps, jambs, pillars, window cills, cooking platform bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting, rubbing and polishing laid over and including bedding layer or screed 20mm thick in cement mortar 1:4 all as specified and directed by Engineer - in - Charge.
M & L applying evenly a tack coat of industrial bituman 85/25 @ 1.2 Kg / Sqm on plaster surface including cleaning of surfaces all as specified and directed by Engineer – in – Charge
Spreading and levelling of earth in layers not exceeding 25cm thick and well ramming including watering as required all as specified and directed by Engineer - in - Charge.
S&F door closer hydraulically regulated, aluminium (Die cast) body, designation No. 3, universal type suitable for door shutter upto 1000mm in width complete all as specified and as directed by Engineer-in-Charge.
S & F bright finished brass 100 mm mortice lock with four levers vertical type with necessary screws etc complete all as specified and directed by Engineer - in - Charge.
M&L Cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate for foundations, fillings and mass concrete all as specified and directed by Engineer – in - Charge.
M & L for chequered cement concrete designer prepolished glossy finished tiles 25cm x 25cm x 25mm thick with grey cement and pigments, heavy duty, set jointed and pointed in neat cement slurry and pigments as in floors over and including 15mm thick screed bed of cement mortar 1:4 complete all as specified and directed by Engineer - in - Charge.
M & L for broken bricks hard core of gauge not exceeding 63mm, deposited, spread levelled in layers n exc 15 cm thick, watered and rammed to a true surface all as specified and directed by Engineer - in - Charge.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. all as specified and directed by Engineer - in – Charge.
M & L brushing neat cement slurry with 3.0 Kg of cement per Sqm all as specified and directed by Engineer - in – Charge.
M & L 15mm thick Screed bed or bedding layer of Cement Mortar 1:6 for laying floor finishes, etc. complete all as specified and directed by Engineer - in - Charge .
M & L vitrified ceramic tiles 10 mm thick ( square/ rectangular ) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer - in - Charge.
Resecuring or easing & adjusting without taking down of shutters of any description exc 1.00 sqm but not exc 2.0 Sqm each complete all as specified and directed by Engineer - in - Charge.
S & F glass dividing strips, 3mm thick, 38mm width and inserted in position to conform to design all as specified and directed by Engineer - in - Charge.
M & L RCC 1:1½:3, (nominal mix), type A-1, using 20mm graded aggregates as in columns, pillars, piers, posts and struts all as specified and directed by Engineer - in - Charge.
M & L RCC 1 : 1½ : 3, (nominal mix), Type A–1 using 20mm graded stone aggregate as in foundation including raft, footings, foundation beams and the like complete all as specified and directed by Engineer - in - Charge.
M & L RCC 1:1½ :3, (nominal mix), Type A-1, using 20mm graded aggregates as in beams, cantilevers, bressummers,, lintels over 1.5mtr clear span etc all as specified and directed by Engineer - in - Charge.
M & L form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge.
M & L form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface of concrete all as specified and directed by Engineer - in - Charge.
Form work to chullah hoods, chajjas, troughs and similar items including edges with rough finished surface of concrete all as specified and directed by Engineer - in - Charge.
M&L Brick work with old size burnt fly ash bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 all as specified and directed by Engineer - in - Charge .
M&L Brick work with old size burnt fly ash bricks, straight or curved on plan exceeding 6 mtr mean radius built in CM 1:4 all as specified and directed by Engineer - in - Charge .
M&L 25mm th PCC 1:2:4 type B-1 using 20mm graded aggregate as in flooring, finished rough and even all as specified and directed by Engineer-in-charge.
M & L 25 mm thick Cement Conrete 1:2:4 type B–0 using 12.5mm graded stone aggregates flooring finished even and rough to receive topping layer all as specified and directed by Engineer - in – Charge .
M & L 10mm thick rendering in Cement Mortar 1:3 on fair faces of brick work or concrete surfaces of ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge .
S & F PVC pipes (SWR) single socketed with rubber ring joints 110mm dia laid in trenches or in floors complete all as specified and directed by Engineer - in - Charge .
S&F PVC ( SWR) bends any radius bore of 110 mm all as specified and directed by Engineer - in - Charge
S & F pressed steel door frames with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, size of frame 105X60mm , complete all as specified and directed by Engineer - in – Charge .
S&F Pillar taps 15mm bore dia, fancy type, cast copper alloy with capstan heads chromium plated screwed down hidh pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed for iron pipe and fixed all as specified and directed by Engineer – in – Charge .
S & F gunmetal globe or gate valve with iron wheel head, screwed both ends for iron pipes 20mm bore complete all as specified and directed by Engineer – in – Charge.
M&L in repairs ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball with minimum weight 210 gm screwed for 20mm bore iron pipe supplied and fixed complete all as specified and as directed by Engineer-in-charge.
S & F grating round 125mm with waste hole of PTMT (minimum weight 40 gms) all as specified and directed by Engineer - in - Charge.
M & L cast iron floor trap 100mm dia with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B–1 in repairs all as specified and directed by Engineer - in - Charge .
S & F 20mm bore medium grade steel tubes galvanised with all fittings laid in trenches all as specified and directed by Engineer - in – Charge .
M&L for Roof treatment to RCC roof as follows :- (a) Providing one coat of approved bituminous primer @ 100 gms per sqm, over dried plastered surface. (b) Applying evenly one coat of industrial bitumen 85/25 @ 1.2 Kg per Sqm over a coat of bituminous primer @ 0.3 Litre per Sqm including cleaning of surface complete. (c) Laying 3 mm thick APP membrane,(mineral finish) reinforced with non woven polyster fabric, by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by Engineer-in-Charge. Makes:-STP, Dr Fixit/ Pidilite,Texas
Certain items of external as well as internal electrification (modular fittings) complete all as specified and directed by Engineer-in-charge.
S&F vitreous china Half stall urinals flat back white minimum with grating and union for discharge pipe , providing & fixing plugs, bedding urinal against wall in CM 1:2 , securing urinal to plugs with & incl 60mm long brass screws, pointing around urinal back in cement , fixing automatic flushing cistern with nbrackets, flush pipe, grating and union for discharge pipe complete all as specified.
Excavating over areas, not exceeding 1.5m in depth for foundations and getting out in soft / loose soil all as specified and directed by Engineer - in - Charge.
All as per Srl item No. here in before but exceeding 1.5m and not exceeding 3m in depth all as specified and directed by Engineer - in – Charge.
Removing excavated material exc.50 m but n exc. 250 m and depositing where directed all as specified and directed by Engineer - in - Charge.
M & L form work to soffits of suspended slabs such as roof slab and similar work not exceeding 200mm thick for rough finished surfaces of concrete all as specified and directed by Engineer - in - Charge .
S & F for stone boulder pitching, laid dry, hand packed tightly all as specified and directed by Engineer - in - Charge.
M&L Loose filling with broken bricks aggregates of gauge 80 to 150mm in soakage pits or soakage well complete all as specified and directed by Engineer – in – Charge
M&L Cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate as in bed to drain pipe including packing under and haunching against the sides of pipes 150mm dia (internal) after these are laid in trenches all as specified and directed by Engineer - in - Charge.
M & L 150mm dia (internal) SGSW pipes grade ‘A’ laid in trenches and jointed all as specified and directed by Engineer - in - Charge.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc all as specified and directed by Engineer - in - Charge.
S & F cast iron cowls 75mm bore all as specified and directed by Engineer - in - Charge.
S & F CI soil waste and vent sand cast pipe 75mm bore in any length with or without ears with cement joints laid in trenches or in floors all as specified and directed by Engineer - in - Charge.
M & L RCC 1:2:4 (nominal mix), Type A-1 using 20mm graded stone aggregates for slabs supported on walls, beams, columns and in shelves, the like all as specified and directed by Engineer - in - Charge .
M & L RCC 1:2:4(nominal mix), Type A-1, using 20mm graded aggregates as in beams, cantilevers, bressummers,, lintels over 1.5mtr clear span etc all as specified and directed by Engineer - in - Charge.
Form work to sides and soffits of floor or roof beams, lintels cantilevers, shelves including supports, over hangs and the like for rough finished surfaces complete all as specified and directed by Engineer – in – Charge.
S&F steel ventilators with top hung shutter including hinges, steel peg stay complete all as specified and as directed by Engineer-in-Charge.
S & F CI soil waste and vent sand cast pipe 100mm bore in any length with or without ears with cement joints laid in trenches or in floors all as specified and directed by Engineer - in - Charge.
S & F CI soil waste and vent sand cast pipe 75mm bore in any length with or without ears with cement joints fixed to walls all as specified and directed by Engineer - in - Charge.
S & F 100mm bore CI branch pieces single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches all as specified and directed by Engineer - in - Charge.
M & L cast iron floor trap 75mm dia with grating including jointing to waste pipe fixed in cement concrete 1:2:4 type B–1 in repairs all as specified and directed by Engineer - in - Charge .
M & L gully traps salt glazed stone ware 150 x 150mm size square or round mouthed type ‘S’ or ‘P’ PCC for bed, trap and surrounds shall be 1:3:6 type C – 1 using graded stone aggregate incldg grating of cast iron all as specified and directed by Engineer - in - Charge.
M&L Cement concrete 1:4:8 type C-2 using 40mm graded crushed stone aggregate as in bed to drain pipe including packing under and haunching against the sides of pipes 150mm dia (internal) after these are laid in trenches all as specified and directed by Engineer - in - Charge.
SCHEDULE 'A' SECTION-II (E&M PORTION)
Taking down aluminium / Copper point wiring (light, fan, socket or power, bell complete fittings such as sockets, ceiling roses, pendants, battens/ conduits (as required), holders, regulators and making good the disturbed surfaces of walls, floors, ceiling etc all as specified and directed by Engineer - in - Charge.
Taking down unserviceable main switches and MCB distribution boards single phase complete all as spd
M & L point wiring complete with 1.5 Sqmm (nominal area) PVC FRLS insulated unsheathed copper stranded conductor cable with colour code in and including medium grade rigid PVC conduit with tees, bends, elbows, couplers, MS junction boxes concealed after cutting chases in wall, floor etc and making good to match with existing surface including sunken iron terminal box, 3mm thick bakelite sheet cover, clips, pipe hooks, brass screws, washers and 1.5 Sqmm single core stranded / solid copper conductor 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth and connecting to earth dolly for One light /bell point/ fan point controlled by one, one way switch all as specified and directed at site by Engineer – in – Charge.
All as per item No. 156 here in before but for socket out let 3 pin 5 amp on independent board all as specified and directed by Engineer - in - Charge
All as per item No. 156 here in before but for socket out let 3 pin 5 amp on same board all as specified and directed by Engineer - in - Charge
All as per Srl item No. 156 here-in-before but with 2.5 Sqmm single core multi stranded copper conductor of 1100 volts grade PVC FRLS insulated and unsheathed cable for one multipurpose switch socket outlet 6 pin, 15 Amps on independent board including 1.5 Sqmm single core stranded / solid copper conductor 1100 volts grade PVC insulated and unsheathed cable as earth continuity conductor to common earth and connecting to earth dolly.
S & F switch piano flush type single pole one way 5 Amp all as specified and directed by Engineer - in – Charge.
S & F socket piano type single pole one way 5 Amp 230 volt AC supply all as specified and directed by Engineer – in – Charge .
S & F switch piano flush type single pole one way 15 Amp all as specified and directed by Engineer - in – Charge.
S&F socket outlet 2 in 1, 3 pin, 5 and 15 Amps, flush type complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing PVC Lamp holder suitable for and including batten fittings ,LED Electric Bulb of 9 W with backalite 20mm back plate complete all as specified & directed, .Make:Anchor/Havells/Legrand
S&F LED Lamp 9 Watt retrofit and connecting complete all as spd and directed.Make: Bajaj/Crompton/Havells
S & F ceiling rose 65 x 50mm three terminals PVC/ polycorbonate, isolated body all as specified and directed by Engineer - in - Charge .
S&F fan regulator electronic stepped heavy duty flush type 230 volt AC single phase fixed on laminated sheet top cover (laminated sheet top cover is included in rates under respective items of point wiring) and connecting up complete all as specified and directed by Engineer-in-Charge.
S & F isolator single pole and neutral 40 Amp 240 volt all as specified and directed by Engineer – in – Charge .
S & F MCB distribution board of sheet metal single pole and neutral 8 way, single door, with 200 Amp rated bus bar 240 volt all as specified and directed by Engineer-in- Charge.
S & F distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting STN 2 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation o MCB's nd isolators etc complete all as specified and directed.
S & F MCB distribution board of sheet metal triple pole and neutral 4 way, single door, with 200 Amp rated bus bar 440 volt all as specified and directed by Engineer-in- Charge.
S & F isolator single pole 40 Amp 240 volt all as specified and directed by Engineer – in – Charge .
S & F isolator triple pole and neutral 63 Amp 415 volt all as specified and directed by Engineer – in – Charge .
S & F submain wiring with two single core cables PVC FRLS insulated unsheathed 6 Sqmm stranded copper conductor drawn in and including PVC conduit with and including PVC insulated 6.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in - Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
S & F submain wiring with two single core cables PVC FRLS insulated unsheathed 4 Sqmm stranded copper conductor drawn in and including PVC conduit with and including PVC insulated 2.5 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in - Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
S & F submain wiring with two single core cables PVC FRLS insulated unsheathed 2.5 Sqmm stranded copper conductor drawn in and including PVC conduit with and including PVC insulated 1.5 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in - Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.
M & L for LED 10W bulkhead fitting with IP-65 engineering plastic housing with clear, single phase 240C, including 1.0 sqmm copper flexible cable twiested three core alongwith flexible PVC conduilt from ceiling rose to fitting testing complete Cat part No. BLRB 18W CW of make Bajaj or equivalent model of make Havells/ Crompton Greaves/ Philips / Wipro as approved by GE. Note : Warranty and test certificate of LED light fittings to be produced before incoporating.
S&F of Ceiling fan of 1200mm sweep mounted in suitable arrangement for operation on 230 volts, single phase, 50 cycle per second, AC supply with electonic type regulator and connecting accessories BEE 5 Star rating and connecting up including three core PVC insulated PVC sheated copper conductor flexible cable from ceiling rose to fan fixing in ceiling complete and making the surface good after fixing the fan complete all as specified and directed. MAKE : BAJAJ/HAVELLS/CROMPTON
S&F of Heavy Duty exhaust fan of 400-450mm sweep mounted in suitable opening arrangement with louvers suitable for operation on 230 volts, single phase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheated copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit fixing in wall and making suitable hole for air freshner fan with necessary finishing of the surface good after fixing the fan complete all as specified and directed by Engg-in- Charge.
S&F and testing LED light fitting 1x18watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through h oles. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin Make- CG/Bajaj/Havells
Supplying and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable XLPE aluminium conductor armoured PVC sheathed 10 Sqmm 4 core nominal cross section in service connections all as specified and directed by Engineer – in - Charge.
S&F of air freshner exhaust fan of 250mm sweep mounted in suitable opening arrangement with louvers suitable for operation on 230 volts, single phase, 50 cycle per second, AC supply and connecting up including three core PVC insulated PVC sheated copper conductor flexible cable 24/0.2mm drawn in flexible PVC conduit fixing in wall complete and making the surface good after fixing the fan complete all as specified and directed.
M&L sub main wiring of PVC FRLS insulated unsheathed two core 1.5 sqmm copper multi stranded conductor including one run of single core copper conductor of size 1.5 sqmm as earth wire drawing in concealed PVC conduit complete all as specified and directed.
KATARIA CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .