Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC NOT AVAILABLE | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹38.0 L+₹3.3 L (9.44%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹40.8 L+₹6.1 L (17.6%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹40.9 L+₹6.2 L (17.8%)Rejected-Finance PLOT NO 17 GF PRATAP NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L4 | Rejected-Finance Being other than lowest |
Tender Value
₹46.3 L
EMD Value
₹92,600
Closing Date
25 Sept 2021, 6:00 pmClosed
GE (East) Delhi Cantt-10
GE (East) Delhi Cantt-10
PROVISION OF SOUNDPROOFING TO COMMENTRY BOX AT CPG, FALSE CEILING TO GUARD ROOM NO 03, VIEW CUTTERS ON WALL BETWEEN GIRLS AREA AND OFFICERS MESS/JCOs TOILET, SHEDS WITH GALVALUME SHEET AT HAND WASHING POINTS OF BOYS COOK HOUSE AT DGNCC CAMP IN THE A
2021_MES_472824_1
GE/DE-41/2021-22
Open Tender
Civil Works
Item Rate
120 days
GE (East) Delhi Cantt-10
Class D Cat a i
8 documents required · 8 mandatory
₹500
Yes
GE (East) Delhi Cantt-10
₹92,600
Yes
19 Oct 2021
4 Sept 2021
2 Oct 2021
4 Sept 2021
25 Sept 2021
13 Sept 2021
4 Sept 2021 - 9 Sept 2021
Amount
Demolition of cement concrete, unreinforced, in ground floors and pavings not exceeding 15cm thickness below or above ground level, complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position complete all as specified and as directed.
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facings, complete all as specified and as directed.
Taking down cement plaster on brick or stone walls, including racking out joints, hacking for key, scrubbing down with water etc., to receive new plaster, complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.50 Sqm and not exceeding 4.0Sqm each and removing from site, complete all as specified and as directed.
Excavation in post holes (or similar holes) in soft/loose soil each not exceeding 0.5 cum getting out, returning, filling in ramming earth or broken rubble in layers not exceeding 25 cm, watering and removing of surplus soil to a distance not exc 50m and making good surfaces, complete all as specified and as directed.
Removal of surplus soil to a distance not exceeding 50mtrs and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and as directed.
Hard core of gauge not exceeding 63mm stone aggregate, deposited, spread and levelled in layers not exceeding 15 cm thick watering and ramming to a true surface, complete all as specified and directed
Plain cement concrete 1:2:4, Type B-2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete, complete all as specified and as directed.
PCC 1:2:4 type B-0 using 12.50 mm graded crushed stone aggregate as in PCC padding over roof, complete all as specified and as directed.
Plain cement concrete 1:2:4 type B- 1 using 20mm graded crushed stone aggregate as in window or door cills, lintels, bressumers, steps, quoins blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundry pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets etc. (including form work), with plain fair faces, including chamfers, weathering, throaing etc., complete all as specified and as directed.
PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in roof kerb, mud stops, platform for OHT, etc., and similar type of works including weathering, slightly rounded or chamfered angles, complete all as specified and as directed.
Brick work with sub class “B” bricks straight or curved on plan exceeding 6mtr mean radius built in cement mortar 1:6 using old size bricks, complete all as specified and as directed.
18-20mm thick Granite stone any type, (table rubbed and polished) in steps, shelves, pillars, window cills, cooking platforms and the like, laid over 20mm thick layer of cement mortar 1:3 after rougheniung of existing concrete surface and applying a layer of neat cement slurry @ 3Kg/Sqm including pointing in white cement 1:2 using marble dust with admixture of pigments to match with shade of stone, including moulding of edges, complete all as specified and as directed.
Factory made 35mm thick second class hard wood for plain framed panelled shutters (any number of panels) with lock rail and panel of 12mm veneered particle board with commercial veneering on both faces. The size of rail & style as per IS: 1003(Part 1), kiln seasoned and chemically pressure treated, complete all as specified and as directed.
Glazed and Skelton shutters using 2nd class hard wood, 35mm thick open rebated and prepared to receive glass or gauge etc., edges of framing plain and chamfered or fitted with cut or mitered beads for securing glass or gauze, size of member of shutter as specified in SSR Part-I section 8, clause 8.23(a) and divided in square complete all as specified and as directed.
Factory made uPVC window frame made of uPVC. extruded sections having an overall dimension (extruded section profile) as per thickness of double glazed sound proof glass thickness with wall thickness 2.0 mm (± 0.2 mm), corners of the frame Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete all as specified by the manufacturer and as per directions of Engineer-in-charge.
100mm size butt hinges extruded anodised aluminium alloy with galvanised mild steel pin type C-21, fixed in repairs, complete all as specified and as directed.
Aluminium alloy handles cast type anodised of size 150mm size, fixed in repairs, complete all as specified and as directed.
Aluminium anodized 150mm size barrel tower bolt of extruded section, fixed in repairs, complete all as specified and as directed.
250 mm size aluminium alloy anodised sliding door bolt with haps, staple ( bolt type ) and fixing clips of sheet, cast of extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, fixed in repair complete all as specified and as directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium beading, complete all as specified and as directed.
Soundproofing/acoustic temper proof argon filled double glazed glass panels (one way vision glass) fixed in uPVC windows/doors (1st glass 12mm and 2nd glass 10mm and filled with insulated argon gap 8mm) blue tinted/film coated (size of glass shall be as directed by Engr in charge) fixed as per manufacturer's instructions with entire fixing accessories, complete all as specified and as directed. Make : Saint Gobain or equivalent.
Glass shelf of 12mm thick blue tinted toughned glass including mounting brackets and clip/plates of stainless steel including connected fittings as per approved design, complete all as specified and as directed.
Providing & erecting double scaffolding, Jacks and props to support the structure provisionally during repair etc., complete all as specified and as directed by Engr in charge.
12mm thick Aluminium Composite Panel with ACP sheet (design and colour shall be as approved by Engr in Charge) fixed with necessary cleats, clamps and fixing accessories, complete all as specified and as directed.
18-20mm thick exterior PVC and WPC Jalli/Panels (Design as approved by Engr-in-Charge) fixed on mild steel square tube including all fixing accessories, complete all as specified and as directed. (Note : Mild steel square tube shall be measured and spearately under respective item).
Aluminium alloy powder coated (50 micron) anodized door frame of section 100mm x 44 mm x 2 mm thick, door shutter of aluminium section of size 85 mm x 44 mm x 2 mm thick, top rail and both styles of size 100 mm x 44 mm x 2 mm thick, lock rail and bottom rail of size 115 mm x 44 mm x 2mm thick incl aluminium anodized snap beading and rubber packing & 5.5 mm thick colour designer glass incl 200 mm long tower bolt-2 Nos, 200 mm long Alm handle -02 Nos on each leaf, 4 lever lock brass 100 mm long mortice lock (Make :- Godrej), & double action floor door spring(Sandhu/Samrat) heavy duty suitable for 1 m wide shutter for each leaf, complete all as specified and as directed.
Powder coated three track aluminium (glazed/ gauged) window shutters sliding type incl 5.5mm thick glass or stainless steel wiremesh, without sash bar aluminium saction weighting 0.55 Kg per mtr including necessary joining cleats, glazing clips, rubber packing, anodised aluminium beading , sliding channel,roller screws including fittings, complete all as specified and as directed by Engr-in-charge.
Powder coated aluminium window and ventilator shutters, side hung type with out sash bars, aluminium sections weighing 0.55 Kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long ( 1 No.) hinges type B-21 100 mm long (2no.) ,aluminium tower bolt 100 mm long (2no.),suitable handle (1 No.), complete all as specified and as directed.
Mild steel TMT bars upto 10mm dia, cut to length, bent to shape required, including cranking, bending, spirally for hopping for columns, hooking ends, and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips quality conforming to Fe-410-S or Fe-410-0, complete all as specified and as directed.
TMT bars 5mm dia and over upto and including10mm dia cut to length, in stirrups and spacers including cutting and bending, hooking ends & binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
Hand rails, half round or other stock section straight portion drilled and countersunk for balusters running bars, for doors, balusters, including framed work such as grills, gratings, chowkats, purlins, rafters etc including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc including dismantling/taking down old mild steel work in similar type of work, complete all as specified and as directed.
Mild steel angle Iron post and struts in fencing including cutting as making hape including welding with proper overlapping & Welding MS Plate with angle iron bottom as directed, drilling holes notching for wire etc embedded in concrete fixed vertically conforming to grade Fe-290-Gde E-165 complete all as specified and as directed.
Mild steel framed work as in doors (as in chowkats) or gates of angle or other section with gusset plates, rails, braces etc., exclusive of steel sheeting or other covering, hanging or fastening and fixing complete conforming to Gde Fe-410-0 or Fe-310-0 including shop coat of red oxide including preparation of surface before fixing, complete all as specified and as directed.
Rolled mild steel Fe-410w (Gde-E-250) quality 'B' Roof trusses (framed), trussed, purlins, crane gantries, rails and fastening and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces cleats etc., complete all as specified and as directed.
Pre-Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed.
2 mm thick Fibre glass reinforced translucent colourd plain/corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall, gate etc., and similar work as required, including taking down existing unserviceable coverings any type, complete all as specified and as directed.
Complete removal of existing roof treatment on top of concrete slabs, cleaning the surface completely by scrubbing and wire brushing and washing with water to prepare roof surface for new treatment. Applying evenly a coat of bituminous primer conforming to IS- 3384 @ 0.5Ltr/Sqm. Over the primed surface, apply a coat of hot blown 85/25 penetration grade bitumen conforming to IS- 702 @ 1.2 Kg/Sqm of the surface area. Applying APP based polymeric mambrane minimum weight 3.6kg/Sqm and of minimum thickness 3mm, reiforced with polyster non woven fabric ( weight not less than 150gm/Sqm ). APP membrane will be laid by torching overlaps with a propane or butane gastorch and laid across the slope from lowest line of roof towards ridge with over laps of 75mm in length side and 100mm on the width side of membrane bonded with hot blown bitumen. Over the APP membrane finally applying a coat of Solar reflective Paint @ 0.30Ltr/Sqm complete all as specified and as directed.
E-board 4mm thick self design type tiles ceiling on GI Powder coated channel/Tee/Grid of make(Armstrong or equivalent in Everest or Charminar) frame work with the following specification including cutting holes to brick wall built in cement mortar & making good in cm 1:3 of cement concrete 1:2:4 type BO complete all as specified and as directed. (a) Plugging to wall around the rooms & supplying & fixing GI Powder coated angle of size 22.2mm x 22.2mm x 0.65mm (b) S&F of 2-3 mm dia GI wire suspenders with adjustable clamps including fixing to ceiling dash free fasterers (c) S&F 29mm x 24.7mm x0.8mm GI Powder coated tee as in main & cross members at 595mm c/c supported suspenders alongwith adjustable clamp to maintain level. ( d) S&F E-board 4mm thick self design type ceiling tiles of size 595mm x 595mm confirming to relevant IS in squares of GI Powder coated Tee with clips made to shape. Shade and pattern of Gypsum board shall be as approved by GE (e) Providing two coats of oil bound distemper to exposed surface of E-Board ceiling.
GI frame work for seamless ceiling comprising of GI perimeter channel 0.55mm thick with two unequal flanges of 20 and 30mm and web of 27mm fixed to surrounding wall using nylon sleeves and screws at 450mm centre to centre/intermediate channel 0.9mm thick having equal flanges of 15mm each and web of 45mm suspended from soffit at approx 900mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2m length) of 0.55mm thickness having kurled web of 50mm and flange of 26mm each with lips of 10.5mm fixed to the intermediate channel at 457mm centre to centre and Hangers 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40 x 3mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long, complete all as specified and as directed.
12mm thick unhydrous Gypsum board ceiling in flat surface, fixed with 2nd class hard wood fillets to metal frame work with GI wire mesh (Wooden fillets, metal frame and wire mesh shall be measured and paid separately under respective item) includinh sunk or raised moulding, complete all as specified and as directed.
60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and as directed. and as directed.
75mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection including finishing the surface even and fair, complete all as specified and as directed.
Machine cut kota stone slab 18-20 mm thick as in flooring laid over and including cement screed base of 15mm thick in cement mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, including dismantling old stone slab flooring with screed, complete all as specified and as directed.
Machine cut kota stone slab 18-20 mm thick as in vertical surfaces shuch as skirtings/dados/ risers of steps, pillars, etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including backing layer of 10mm thick in cement mortar 1:4 including dismantling of old tiles with backing, complete all as specified and as directed.
Vitrified coloured ceramic tiles dark shade 10mm thick (square/rectangular) polished, area of tiles not exceeding 0.36Sqm each in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:4 including dismantling of old tiles with backing, complete all as specified and as directed.
Vitrified coloured ceramic tiles dark shade 10mm thick (square/rectangular) polished, as in vertical surfaces shuch as skirtings/dados/ risers of steps, pillars, etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including backing layer of 10mm thick in cement mortar 1:4 including dismantling of old tiles with backing, complete all as specified and as directed.
Glazed Coloured Ceramic tiles in vertical urfaces of skirtings, dados, sides of pillars, risers of steps, size of each tile 450mm x 300mm x 6-7mm thick set and joint in neat cement slury and pointed in white or colour cement to match laid over 10 mm thick screed bed in CM 1:4, complete all as specified and as directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished even and smooth without using extra cement, complete all as specified and as directed.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement, complete all as specified and as directed.
Taking down cement plaster / duster bed PCC of Column, chajja, Parapets of roof, facia, drops etc and making good with cement plaster 10mm thick in CM 1:3 with PCC 1:2:4, (average thickness of PCC 25mm) as required, brushing neat cement slurry with 3.0kg of cement per sq. metre including necessary form work and scaffolding upto 3rd floor including fixing of wire netting where required to match the existing surfaces, complete all as specified and as directed.
Rendering 5mm thick on fair faces of concrete surfaces as in ceilings in cement mortar 1:3 finished even and smooth without using extra cement, complete all as specified and as directed.
Complete removal of existing treatment on old treated surfaces of walls and applying a layer of Birla white/J K white wall care putty and sanding the surface to a smooth finish and applying two coats of oil bound distemper, complete all as specified and as directed.
Preparation of newly plastered surfaces of walls and applying two coat of cement based paint , complete all as specified and as directed.
Preparation of newly palstered surfaces of walls and applying a layer of Birla white/J K white wall care putty, applying a coat of primer to smooth finish and finally finishing the wall surface with two coats of plastic emulsion paint, complete all as specified and as directed.
Preparing newly plastered surfaces of ceilings and applying three coats of white wash, complete all as specified and as directed.
Two or more coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification, complete all as specified and as directed.
Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surface, complete all as specified and as directed.
Preparation of old treated wooden surfaces and applying two coat of synthetic enamel paint on wooden surfaces of any description, not otherwise described over 10cm width or girth, complete all as specified and as directed.
Preparation of new steel surfaces and applying two coats of synthetic enamel paint on surfaces of any description exceeding 10 cm width or girth over a coat of red oxide, complete all as specified and as directed.
4.00mm thick figured glass, pin headed type, and glazing with oil putty in square not exceeding 0.5 Sqm.in each pane, complete all as specified and as directed.
Point wiring complete with 1.5 Sqmm (nominal area) FRLS, PVC insulated un-sheathed and multistranded copper conductor cable ISI marked and including PVC concealed conduit ISI marked of size 20 mm dia medium grade and PVC conduit fittings such as tees, bends, elbow, reducers except conduit junction box (junction box will be of MS) including FRLS, PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and including Metal flush box of suitable size for fixing switches/sockets/fan regulator etc , with and including laminated sheet of suitable size and making good surface as original by plastering, whitewash/colour and distemper etc complete all as specified and as directed for the following :- one light point / fan point/ wall fan point/ bell/ buzzer controlled by one 1-way switch/ bell push.
All as per description of Srl item No. 65 here-in-before but for one socket outlet 6 Amps on independent board.
All as per description of Srl item No. 65 here-in-before but with 2.5 Sqmm (nominal area) FRLS, PVC insulated un-sheathed and multistranded copper conductor cable ISI marked and 1.5 Sqmm (nominal area) FRLS, PVC insulated un-sheathed and multistranded copper conductor cable ISI marked as earth wire for one socket outlet 16 Amps on independent board.
Replacement of Modular switch piano flush type, single pole, 01 module, 6 Amps, complete all as specified and as directed.
Replacement of Modular socket two-in-one, 5 pin, 6 Amp universal type, 02 module, complete all as specified and as directed.
Replacement of Modular switch piano flush type, single pole, 01 module, 16 Amps, complete all as specified and as directed.
Replacement of Modular socket two-in-one, 6 pin, 16/6 Amp multipurpose type, 02 module, complete all as specified and as directed.
Replacement of Ceiling rose, insulated body, 3 terminal, 240 volts, 5 Amps, complete all as specified and as directed.
Replacement of Wall mounting tube light fitting, 22 watt including making all electric connections using PVC Sheathed copper conductor flexible cable, complete all as specified and as directed.
Replacement of MCB DB confirming to IP 43 - IK 09 with double door, SPN 12 way, double door complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces, complete all as specified and as directed.
Replacement of MCB C Curve type, 10 kA, 10 to 32 Amp, Single Pole with over load and short circuit protection, complete all as specified and as directed.
Replacement of MCB C Curve type, 10 kA, Single Pole and Neutral of 40 to 63 Amp capacity, complete all as specified and as directed.
Replacement of Sheet metal enclosure, SPN type with two pin & earth plug and socket (Industrial type DB) with and including one mini MCB SP, C Curve type of capacity 20 Amp, 10 KA, fixed in repairs, complete all as specified and as directed.
Replacement of Sub main wiring with 2 run of 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC conduit with and including 6.0 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB, complete all as specified and as directed. Note :- a) The conduit and conduit accessories shall be measured and paid as one unit. b) The cost of earth wire is deemed to included in he quoted rates.
LED security light luminaire 45 watt pressure die cast aluminium housing with heat resistance toughned glass and IP- 66 protection with and including driver/transformer and including connector, complete all as specified and as directed.
Street light fitting bracket, 1.5 mtr long made out of galvanized iron pipe of 40 mm dia size light grade complete with nut, bolts, washer etc., inclusive of one primer coat, one under coat and one finishing coat of silver paint, complete all as specified and as directed.
Rigid non metallic conduit of size 25mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth etc., and inclusive of all fixing accessories such as couplers, lock nuts, saddles, pipe hiiks etc., complete all as specified and as directed.
Round shaped 12Wall 220 volts AC recessed type LED light fitting with high efficency PMMA diffuser having soft glare free light with including driver, holders, LED lamp etc., suitable for ceiling fittings including connecting woth three core flexible copper conductor of suitable size, complete all as specified and as directed.
Earth continuity conductor or main earthing lead of 4mm dia galvanised steel wire, fixed to wall on battens or into recess or chasses or burried in ground or drawn in conduit/pipe or fixed to pole or in any other indicated situation for loop earthing etc., as required, complete all as specified and as directed.
Earthing complete with GI earth plate electrode 600 mm x 600mm x 6mm thick burried directly in ground not less than 2.25 mtrs below ground level, with top edge of the plate not less than 1.5 mtrs deep below normal ground level, connected to galvanised earth wire 4mm by means of bolts, nuts check nuts to earth test point including necessary PCC 1:2:4 type B-1 pit, cover frame, GI pipe 15mm dia light grade for protection of earthing lead and GI pipe 20 mm dia medium grade for watering pipe with funnel, wire mesh, salt, charcoal dust and excavation, complete all as specified and as directed.
NOTE:- For minimum fair wages ,EPF and payment to labour employed, refer Sch A Note No-17,18 and Special Condition No 5 & 21.2 of this tender. Contractor must produce all the relevent record such as payment made to labour, EPF etc at the time of payment of RARs/Final bill. No payment will be released to contrator without producing the proper record.
NOTE:- Irrespective of whatever specified elsewhere in tender documents, all the debris/waste materials produced out of above mentioned work shall be removed out of Cantonement land and disposed off at locations notified by the Delhi Cantonment Board for disposal of waste building materials within NCR area, without any extra cost to Department under own arrangement of contractors. The rates quoted by the contractors against the items catered here-in-above in the BOQ are inclusive of said provision.
aggarwal engineers contractors
garnet engineers contractors
M/s Durga Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .