Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC 1389 RADHETENAMENT SOCIETY SARDAR ROAD SURENDRANAGAR SURENDRA NAGAR GUJARAT 363001 | SURENDRANAGAR | GUJARAT | 363001 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹21.4 L+₹69,225 (3.34%)Rejected-Finance COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹21.6 L+₹90,890.50 (4.38%)Rejected-Finance AT ROAD NEAR RENUKA CINEMA P O DIST TINSUKIA ASSAM PIN 786125 | TINSUKIA | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹21.7 L+₹1.0 L (4.87%)Rejected-Finance 16 BAITHAKKHANA ROAD 16 BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH BAITHAKKHANA ROAD SEALDAH KOLKATA | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹22.2 L+₹1.5 L (7.02%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹20.5 L
EMD Value
₹41,000
Closing Date
14 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Chabua
GE (AF) CHABUA, POST-CHABUA AIR FIELD, DIST-DIBRUGARH, ASSAM-786102
REPAIR/MAINTENANCE OF EXTERNAL ELECTRIC SUPPLY SYSTEM, SUMMER APPLIANCES AND ALLIED WORKS AT STATION BALIJAN UNDER GE (AF) CHABUA
2023_MES_582439_1
447/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (AF) Chabua
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (AF) CHABUA
₹41,000
Yes
20 Mar 2023
22 Feb 2023
16 Mar 2023
22 Feb 2023
14 Mar 2023
7 Mar 2023
22 Feb 2023 - 1 Mar 2023
Amount
Schedule A Part-I
Supply, laying in trenches/through pipes under road, floor/on wall/on pole or any other indicated place & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, of size 3 core 95 sqmm nominal cross section including taking down of old unserviceable cable complete all as specified and as directed.
Supply laying & testing of XLPE insulated, armoured, heavy duty electric under ground cable with stranded aluminium conductor, 1100 volts grade, laid in trenches, sleeving through pipes or fixed on poles & walls or laid under floors including jointing with suitable size aluminium lugs of size 25 Sqmm nominal cross section x 3.5 core including taking down old unserviceable cable complete all as specified and as directed.
All as per item No. 2 here-in-before but of size 35 Sqmm X 3.5 core complete all as specified and as directed.
All as per item No. 2 here-in-before but of size 50 Sqmm X 3.5 core complete all as specified and as directed.
All as per item No. 2 here-in-before but of size 70 Sqmm X 3.5 core complete all as specified and as directed.
All as per item No. 2 here-in-before but of size 95 Sqmm X 3.5 core complete all as specified and as directed.
All as per item No. 2 here-in-before but of size 120 Sqmm X 3.5 core complete all as specified and as directed.
Supply and fixing steel tubes, galvanised, light grade, ISI marked 80mm bore for protection of cable under floor, road and on wall complete all as specified and as directed.
Excavating in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches in soft/loose n.exc 1.5m wide and exc 1.50m but n.exc 3.0 m in depth for foundation or shafts, wells cesspit, manholes, pier holes, cable laying, sewage/water lines etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed.
Removing excavated material to a distance nexc 50m and depositing where directed at a level nexc 1.5m above the starting point complete all as specified and directed.
Material and labour for sand cushioning (dry) in trenches for protection of UG cable (below, above and around the UG cable laid in trenches) of 230mm spread thickness and consolidated (punned) up to 180mm thickness complete all as specified and directed. Note:- Punned thickness shall be measured for payment.
Materials and labour for brick work with Sub Class 'B' bricks well burnt laid breadth wise along the length or cable laid in trenches over sand cushion laid for UG cable protection complete all as specified and directed.
S&F in repairs cable jointing kit for 11 KV (earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
S&F in repairs cable jointing kit for 11 KV (earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
S&F in repairs cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed.
Dehydration of HV/EHV grade transformer oil (On line/off line), minimum three cycles to achieve dielectric strength upto 60KV for EHV grade and upto 40 KV for HV grade, complete all as specified and directed. Note:- Centrifuging Machine with all T&P & testing equipment required for dehydration to be arranged by contractor.
Supply and filling, transformer oil EHV grade as per IS-335 of 1993 Part-II, complete all as specified and directed.
Supply and stringing in repair ACSR conductor of any size for LT over head line as directed including fixing to insulators with proper size of binding wire complete all as specified and as directed.
All as per item No. 20 here-in-before but but GI wire 4 mm dia complete all as specified and as directed.
Supply and fixing in repairs mild steel galvanised stay assembly set complete comprising of 14mm dia, 400mm long stay bow, 1800 mm long stay rod 20mm dia, 300mm x 300mm x 6mm stay plate, thimble, GI stay wire of 7/8 SWG upto required length including loop type insulator of vitreous porcelain, small size with overall dimensions 90x140mm, clearance of hole 25.5mm, all as shown in electrical plate No.1 of MES Schedule part-I 1991 complete all as directed.
M&L in repairs for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of aluminum paint over a coat of red oxide primer, complete all as specified and as directed.
Supply and fixing steel tubular pole, swaged, complete with cast iron base plate, finial taper plug, bolts, nuts, washer and screws including painting with two coats of aluminium paints over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to portion embedded in PCC including numbering of poles with two coats of synthetic enamel paints, type 410-SP-22 (8.5 meter long) complete all as specified and directed. Note:- Earthwork and PCC shall be measured and paid separately under respective items.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation, filling and mass complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate in foundation, filling and mass complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate in copings to poles & the like etc including weathering, slightly rounded or chamfered angles and throating as complete all as specified and directed.
S&F in repair Air break Switch triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 200 amps suitable for 11000 volts complete all as specified and directed.
S&F in repair drop out expulsion fuse single pole suitable for 11000 volts grade upto 50 amps complete all as specified and directed.
S&F in repairs Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50 mm height, 65mm dia for 550 volts grade complete all as specified and directed.
S&F in repairs pin type insulator porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two galvanized iron washers and one galvanized iron nut, 150 mm height, 150 mm dia for working pressure, 11000 volts grade complete all as specified and directed.
S&F in repairs disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type white, brown or green single disc assy for tension with tension clamps for conductors, working pressure, 11000 volts complete all as specified and directed.
Re-stringing Over Head Line ACSR Conductor and earth wire of any size and type on LT poles including disconnection on Existing Lines by un-binding at Each Pin/Shackle Type Insulator, re-fixing the same after stretching Conductor, removing excess Sag, maintaining proper distance between Conductors adjusting line dividers etc and cutting trimming of tree branches upto 2 mtr clear distance from wire, complete all as directed.
Supply and fixing in replacement rubber mat of size 1 meter x 2 meter x 10 mm complete all as specified and directed.
Disconnect and taking out the Numeric/ Microprocessor based relay of any type of any Make from 11 KV HT panel, cleaning the contacts, calibrating the relay by conducting secondary injection tests, checking of current transformer, rectification of defects in control wiring for proper tripping of circuit breakers through CTs and relay and tripping coils, adjustment/setting to plug and time multiplier settings of the relay to achieve the discrimination in tripping, tune/synchronise upstream breaker relay settings, re-installation of relay, testing & commissioning etc complete all as specified and as directed.
S&F in repair Master Trip Relay suitable for 11 KV HT panel for protection system complete all as specified and directed.
S&F in repair 110V DC closing coil for 11 KV HT panel for protection system complete all as specified and directed.
S&F in repair 110V DC tripping coil for 11 KV HT panel for protection system complete all as specified and directed.
Taking down HT switch gear (Vacuum circuit breaker) of capacity 11 KV 250/350 MVA comprising of following repairs, overhauling, servicing and refixing the same after repairs/ overhauling:- (a) Tripping off the breaker, lowering the breaker with raising/lowering handle and pulling out the breaker complete from the panel along with the trolley for servicing/inspection/overhauling. (b) Servicing/Inspecting/checking of automatic safety shutter operation for serviceability and replacement of spares if required. (c) Servicing/Inspecting/checking of circuit spout and circuit spout connections for RYB phases and replacement of spares if required. (d) Dismantling and checking of cross bar assembly, fixed contacts and current carrying parts of the breaker, trolley, insulated assembly and checking lamination with clamps, epoxy spout, isolator assembly etc. (e) Setting, reassembling, cleaning, adjustment of fixed contacts, main contact, arcing contacts and chamber baffle pot assembly, moving contact for proper setting of auxiliary contacts operating mechanism. (f) Servicing/Inspecting/checking of secondary sockets/bus bar earthing plugs/earthing sockets and replacement of spares if required. (g) Checking, setting and adjustment of lowering and raising operation of the breaker trolley. (h) Lubrication and greasing of all moving parts of the trolley, stopper bolt for proper operating and closing of shutter gear, isolation resistance of trolley of with vacuum interrupter assembly.
Item No. 39 contd... (j) The inspection of HT switch gear shall involve:- (i) Inspection of truck & hoist assembly. (ii) Inspection of tank assembly & barriers. (iii) Inspection of assembly & components of solenoid assembly. (iv) Inspection of assembly & components of dependent mechanism. (v) Inspection of assembly & components of spring box mechanism. (vi) Inspection of motor mechanism spring charge assembly (vii) Inspection of assembly of trip unit & related components Notes:- (i) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of VCB panels with approved colour all as per existing etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. (ii) Major spares like Breaker bushings, vacuum interrupter assembly, bus bar spout, bus bar spout connections, circuit spout/circuit spout connections/buffer fixed contacts, moving contacts, tank assembly/barriers, solenoid spares, dependent/spring mechanism/ motor mechanism, trip unit etc will be measured and paid separately under relevant items of Schedule 'A'. However the rate quoted shall be deemed to include for any other minor spares require replacement.
Supply and fix in repairs LED Indication Lamps for VCB panel complete all as specified and directed.
S&F in repairs single unit resin cast type current Transformer of rating 11 KV, ratio 30-15/5-5A, burden 5P10 for protection and 10VA for metering complete all as specified and directed.
S&F in repairs single unit resin cast type potential Transformer of rating 11 KV, ratio 11KV/ √3/110V/√3 burden 100VA, pistol type complete all as specified and directed.
M&L for dismantling the cable connections of four pole/ three pole Air circuit breaker of capacity 800 to 1250 Amps, 415 V, 50 Hz of any make, strip opening the Air circuit breaker, inspecting the parts for serviceability/overhauling complete and carrying out the following repairs/maintenance:- (a) Cleaning the insulation parts including bushings with CTC solution. (b) Checking the alignment and condition of movable and stationary contacts and adjust them all as per manufacturer's instructional manual (c) Check the bolts, nuts, washers, cotter pins and all terminal connections are in place and tights. Replace the worn-out parts. (d) Check arching contact for damage . (e) Clean and lubricate the operating mechanism with a light machine oil for pins and bearings and with a non-hardening grease for the wearing surfaces . Adjust breaker operating mechanism all as per manufacturer's instructional manual . (f) Checking / inspecting shunt trip coil for serviceability and replacing the same if required. (g) Checking control device free for operation. (h) Check after servicing the circuit breaker to verify the contacts move to the fully opened and fully closed positions, that there is an absence of friction and that the electrical operation is functional Note:- (i) The rate quoted deemed to be inclusive of T&P and minor spares like lubricants, nuts/bolts/washers/ pins etc. (ii) Major spares like Shunt release & trip coil etc will be measured & paid separately under relevant schedule items.
Supply only fixed arching contact suitable for air circuit breakers of rating 800 Amps to 1250 Amps complete all as specified and directed.
Supply only moving arching contact suitable for air circuit breakers of rating 800 Amps to 1250 Amps complete all as specified and directed.
Supply only shunt release (110 /220 V DC or 240 V/415 V AC) suitable for air circuit breakers of rating 800 Amps to 1250 Amps as all per existing of Make complete all as specified and directed.
Supply only under voltage release 240V AC for air circuit breakers of rating 800 Amps to 1250 Amps as all per existing of Make complete all as specified and directed.
Supply only trip coil suitable for air circuit breakers of rating 800 Amps to 1250 Amps complete all as specified and directed.
Supply only drawout breaker suitable for air circuit breakers of rating 800 Amps to 1250 Amps complete all as specified and directed.
Supply and fix motor 240 V AC for air circuit breakers of rating 800 Amps to 1250 Amps complete all as specified and directed.
Supply and fix in replacement Tap changer assembly of 11/0.433 KV transformer 500 to 750 KVA including replacing worn out connection sleeves, insulated plates, nut, bolts & washers and testing after replacement complete all as specified and directed.
S&F in repairs bushing with insulator, packing, nut, washers etc on HT side suitable for 500 KVA to 750 KVA, 11000/433V complete all as specified and directed.
S&F in repairs bushing with insulator, packing, nut, washers etc on LT side suitable for 500 KVA to 750 KVA, 11000/433V complete all as specified and directed.
Supply and fixing in replacement of heavy duty breather assembly of capacity 0.5 kg with silica gel crystal complete all as specified and directed.
Balancing of load on three phases and neutral of transformer by applying necessary engineering efforts like interchanging of jumpers, interchanging of service connections on over head conductors, in LT feeder pillar boxes or any other such efforts to make a balanced distributions of electrical load on transformer all as directed and required as per site conditions including submission of corrected readings of meters. Note:- The unit rate quoted will include the cost of necessary tools, safety devices and plants required for the purpose.
Supply and fixing in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 25 mm bore pipe complete all as specified and directed.
Supply and fixing in repairs gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed for 50 mm bore pipe complete all as specified and directed.
Supply and fix, in repairs, LED 25 to 40 watts post top lantern with aluminium die-cast housing cum heat sink in IP-65 protection including all fixing arrangements, complete all as specified and directed.
Supply and fix in repairs, garden light fitting, 8 to 12 watts LED bollard with soft 360 degree light IP-65 protection, resistant to corrosion better optics for uniform distribution including all fixing arrangements, complete all as specified and directed.
Dismantling and taking down old Aluminium strip 25x3.15 mm (lightning conductor) with saddles and air termination from roof/wall and making good the surface of wall/roof and white/colour washing to match with the existing surface complete all as specified and directed.
Supply and fix in repairs Air termination, single pointed aluminium rod 12mm dia and 300mm long complete all as specified and directed.
Supply and fix in repairs Aluminium strip 25x3.15 mm with PVC/porcelain insulators, nut bolts, fixing screws etc. for roof conductors and down conductors on wall/roof all as specified and directed.
M&L for earthing complete with galvanized mild steel earth plate electrode 600X600X6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including GI earth strip 32 x 6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of HT/LT equipments etc at the other end, earth strip encased in and including 50 mm bore GI medium grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x 6mm flat iron clamps, bolts, nuts and washers and including providing watering pipe 20mm bore GI pipe medium grade from Bottom of concrete pit to top of earth plate electrode complete all as specified and shown in electrical plate No 3 of MES SSR Part-I. The scope of work includes necessary excavation and earth work in any type of soil, removal of soil upto 50 metre, PCC pit with precast RCC cover, charcoal/salt, funnel, CI frame etc including taking down old unserviceable earthing complete all as specified and as directed. NOTES:- (i)The concrete pit shall be made in PCC 1:3:6 type C-1, using 12.5mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover shown in electrical plate No 3 of MES SSR Part-I shall be provided. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be measured and paid through deviation order. (iii) Item includes cost of 7.5 metre earth strips. Any variation in length shall be adjusted through deviation order. (iv) Earth plate electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
M&L for earthing complete with copper earth plate electrode 60 x 60 cm x 3.15 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including copper earth strip of size 20 x 3 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end and connected to metallic bodies of HT/LT equipments etc at the other end, earth strip encased in and including 50 mm bore GI medium grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x 6mm flat iron clamps, bolts, nuts and washers and including providing watering pipe 20mm bore GI pipe medium grade from Bottom of concrete pit to top of earth plate electrode complete all as specified and shown in electrical plate No 3 of MES SSR Part-I. The scope of work includes necessary excavation and earth work in any type of soil, removal of soil upto 50 metre, PCC pit with precast RCC cover, charcoal/salt, funnel, CI frame etc including taking down old unserviceable one complete all as specified and as directed. NOTES:- (i) The concrete pit shall be made in PCC 1:3:6 type C-1, using 12.5mm graded crushed stone aggregate 40mm thick precast cover slab of RCC (1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover shown in electrical plate No 3 of MES SSR Part-I shall be provided. Reinforcement in RCC cover shall be of 8mm dia TMT bars laid @150mm c/c both ways. (ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be measured and paid through deviation order. (iii) Item includes cost of 7.5 metre earth strips. Any variation in length shall be adjusted through deviation order. (iv) Earth plate electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides.
M & L for maintenance free chemical earthing system complete with 03 (three) nos copper bonded rods, 17.2 mm dia 3000 mm long electrode buried at suitable distance apart directly in ground, to bore holes of 120 mm dia vertically to a depth not less than 3.60 mtr deep below ground level with top edge of earth electrode at a depth not less than 100 mm below normal ground level, provision of clamps or brazed or both for each copper bonded rods made of copper and copper strip of size 25 x 3 mm & strip connection on the top of the electrode and copper strip of size 25 x 3 mm for inter connection of 03 nos copper bonded rods and laying at least 500 mm below in the ground and further connected to test point terminal block, including back filling of bore holes with advanced earth enhancing compound 96 kilogram (minimum) for artificial treatment to soil so as to achieve earth resistance below 01 Ohms as specified in para 19.140 of SSR Part-1 (2009), including provision of earthing pit in PCC(1:3:6) type C1 pre-cast cover RCC slab of size 400 x 400 x 50 mm with one handle made out of 8 mm dia round bar, including necessary earth work and three coats of white wash on plastered surface (exposed surfaces) and testing complete all as directed and including necessary earth work and testing complete all as specified and directed. Note:- Taking down old unserviceable dilapidated chemical earthing are included in quoted rate.
S&F in repairs power factor improvement static condenser (capacitors) of required capacity, complete all as specified and directed.
S&F in repairs APFC Relays with auto set function having 7+1 steps, 8 stage suitable for 415 Volts including necessary connections complete all as specified and directed.
Supply and fixing in repair power contactors 3 pole rating 25 Amps, with auxiliary contact 01 NO, 01 NC complete all as directed.
Supply and fixing in repair power contactors 3 pole rating 30 Amps, with auxiliary contact 01 NO, 01 NC complete all as directed.
Supply and fix in repairs copper strip 20 x 3.15 mm with PVC/porcelain insulators, nut bolts, fixing screws etc. for roof conductors and down conductors on wall/roof all as specified and directed.
Schedule A Part-II
Taking down geyser of any capacity from wall mountings after disconnecting electrical and water connections to carry out repairs. Refixing of geyser of any capacity to wall mountings and making electrical and water connections, testing and commissioning Note:- Repairs/replacement of parts carried out will be measured and paid separately under respective items.
M&L for preparation of old painted surface of geyser of capacity 25 ltrs and applying one coat of synthetic enamel paint (white colour) complete all as specified and as directed.
Taking out complete internal assembly i.e. inner tank, inlet and outlet assembly, heating element, thermostat etc, of geyser of capacity 25 litres, de-scaling the geyser inner tank using appropriate chemical (descaling agent), cleaning and washing complete accessories, reassembling the same complete all as specified and as directed.
Taking out complete internal assembly i.e. inner tank, inlet and outlet assembly, heating element, thermostat etc, of geyser of capacity 50 litres, de-scaling the geyser inner tank using appropriate chemical(descaling agent), cleaning and washing complete accessories, reassembling the same complete all as specified and as directed.
Repair to copper/steel inner container of geyser of 25 ltr capacity by necessary welding/ brazing to check the water leakage, testing by applying specified air pressure to ensure leak proof, reassembling of geyser complete all as specified and as directed.
Repair to copper/steel inner container of geyser of 50 ltr capacity by necessary welding/ brazing to check the water leakage, testing by applying specified air pressure to ensure leak proof, reassembling of geyser complete all as specified and as directed.
Supply and fix in repair of apparatus plate assembly of brass suitable for 25 ltr capacity geyser with collar, gasket, inlet and outlet facilities, housing to accommodate heating element, thermostat, thermal cut out complete all as specified and directed. Note:- Cost of drilling work, fixing accessories like nuts, bolt, washer/check nut etc and taking down and refixing of geyser are deemed to be included in the quoted rate.
Supply and fix in repair apparatus plate assembly of brass suitable for 50 ltr capacity geyser with collar, gasket, inlet and outlet facilities, housing to accommodate heating element, thermostat, thermal cut out complete all as specified and directed. Note:- Cost of drilling work, fixing accessories like nuts, bolt, washer/check nut etc and taking down and refixing of geyser are deemed to be included in the quoted rate.
Supply and fix in repair glass wool of superior quality for geysers complete all as specified and as directed.
Supply and fix in repair thermostate switch for geyser 25 ltrs capacity complete all as specified and as directed.
Supply and fix in repair heating element 1.5 KW, A/C 230 Volts (Cup/Triangular Type), complete all as specified and as directed.
Supply and fix in repair heating element 2 KW, A/C 230 Volts (Cup/ Triangular Type), complete all as specified and as directed.
Supply and fix in repair safety valve/ fusible plug (brass) 15 mm bore for geyser complete all as specified and as directed.
Supply and fix in repair (Neon) Indicator lamp (red/green) round/rectangular type for geyser complete all as specified and as directed.
S&F in repairs PVC insulated sheathed copper conductor 2.5 sqmm 3 core as in connecting wire of geyser complete all as specified and as directed.
S&F in repairs PVC heavy duty hot and cold water pipe 450mm long fixed both side with brass ferrule nuts for 25/50 ltrs capacity geysers for inlet/out let pipe complete all as specified and as directed.
Materials and labour for rewinding of ceiling Fan complete upto 1400 mm sweep with heavy duty super enamelled copper winding wire of existing gauge including all insulation materials, varnishing, heating, greasing etc. cutting and removing the old burnt winding complete all as specified and as directed . Note:- Replacement of unserviceable parts like capacitor, bearing, bush, hanging clamp, reel & nut bolt etc measured and paid separately.
All as per item No. 88 here in before but Exhaust Fan upto 300 mm sweep complete all as specified and as directed.
All as per item No. 88 here in before but Exhaust Fan 380 mm sweep complete all as specified and as directed.
Supply only Ball bearing for ceiling Fan No 6200 complete all as specified and as directed.
Supply only Ball bearing for ceiling Fan No 6201 complete all as specified and as directed.
Supply only Ball bearing No 6206 for exhaust Fan upto 450mm sweep complete all as specified and as directed.
Supply only Gun metal bush suitable for upto1400 mm sweep ceiling Fan, complete all as specified and as directed.
Supply only Rubber insulator (reel type) complete all as specified and as directed.
Supply only Fan capacitor of capacity 2.5 mfd epoxy filled type complete all as specified and as directed.
Supply only Fan capacitor of capacity 3.5 mfd epoxy filled type complete all as specified and as directed.
M&L for painting of Ceiling Fan complete upto 1400 mm sweep with one coat of white paint/existing fan using spray machine painting with synthetic enamel paint including cleaning, washing of surfaces complete all as directed.
Disconnecting from socket out lets split type/window AC of capacity upto 2 ton of any brand, servicing by dusting, cleaning of indoor and out door units, rectifying gas leakage by applying necessary brazing, adjusting and rectifying faulty operation of electrical and electronic remote control panels, replacing of perished electrical wires for proper connection from voltage stabilizer, reinstalling the units to its original position, replacement of remote cell and testing complete all as specified and directed. Note:- Spare parts shall be measured & paid separately under relevant items.
All as per item No 99 here in before but refrigerators of capacity upto 280/310 ltr complete all as specified and directed.
All as per item No 99 here in before but refrigerators of capacity upto 320/405 ltr complete all as specified and directed.
Dismantling of old unserviceable compressor from split type AC 2 ton, supply and fixing new hermetically sealed unit compressor of same specifications including necessary recharging of refrigerant and brazing etc and provision of new bushes grommets, sleeves, washers, mounting rubbers, nuts & bolts terminal covers & clips and testing all as specified and directed.
Dismantling of old unserviceable compressor from split type AC 1.5 ton, supply and fixing new hermetically sealed unit compressor of same specifications including necessary recharging of refrigerant and brazing etc and provision of new bushes grommets, sleeves, washers, mounting rubbers, nuts & bolts terminal covers & clips and testing all as specified and directed.
Dismantling of old unserviceable compressor from refrigerator 280/310 ltr capacity, supply and fixing new hermetically sealed unit compressor of same specifications including necessary recharging of refrigerant and brazing etc and provision of new bushes grommets, sleeves, washers, mounting rubbers, nuts & bolts terminal covers & clips and testing all as specified and directed.
Dismantling of old unserviceable compressor from deep freezer 320/405 ltr capacity., supply and fixing new hermetically sealed unit compressor of same specifications including necessary recharging of refrigerant and brazing etc and provision of new bushes grommets, sleeves, washers, mounting rubbers, nuts & bolts terminal covers & clips and testing all as specified and directed.
Dismantling of old unserviceable compressor from water cooler 40/80 ltr capacity, supply and fixing new hermetically sealed unit compressor of same specifications including necessary recharging of refrigerant and brazing etc and provision of new bushes grommets, sleeves, washers, mounting rubbers, nuts & bolts terminal covers & clips and testing all as specified and directed.
Supply only Capillary Tube (copper) suitable for window type AC/split AC upto 2 Ton complete all as specified and as directed.
Supply only Filter strainer (copper) suitable for window type AC/split AC, complete all as specified and as directed.
Supply only split out door fins type aluminium condenser of capacity 2 Ton, complete all as specified and as directed.
Supply only Starting capacitor 100/120 mfd, complete all as specified and as directed.
Supply only Starting capacitor 80/100 mfd, complete all as specified and as directed.
Supply only Running capacitor 36 mfd, complete all as specified and as directed.
Supply only Running capacitor 45/50 mfd+06 mfd, complete all as specified and as directed.
Supply only Running capacitor 50 mfd+4 mfd, dual cap, complete all as specified and as directed.
Supply only Starting relay complete all as specified and as directed.
Supply only Contactor relay for split type AC complete all as specified and as directed.
Supply only blower Fan (PVC) for split type AC upto 2 Ton Capacity, complete all as specified and as directed.
Supply only inner Blower Fan for window AC 1.5 ton complete all as specified and as directed.
Supply only indoor fan motor for split type AC upto 2 ton capacity complete all as specified and as directed.
Supply only outdoor fan motor for split type AC upto 2 ton capacity complete all as specified and as directed.
Supply only Swing motor of lower shutter complete all as specified and as directed.
Supply and charging of refrigerant R-22/307 complete all as specified and as directed.
Supply and fix in repairs PCB Board for split type AC upto 2 ton complete all as specified and as directed.
Taking down carefully u/s indoor electronic type PCB at existing location repair and refixing split type AC of capacity 1.5 to 2.0 Ton complete all as specified and as directed.
S&F in repairs Display board for upto 2 Ton AC complete all as specified and as directed.
S&F in repairs Sensor for indoor unit complete all as specified and as directed.
Supply & fix in repairs remote control for split/window AC complete all as specified and directed.
Taking out voltage stabilizer by disconnecting existing cable for u/s stabilizer of upto 5 KVA capacity including repairing/replacement of push on switch, relay transistor, diode, voltmeter, indicator lamp, high low cutout, MCB, complete parts along with testing and commissioning and transportation charges from site to workshop complete all as specified and as directed.
Supply and replacing cooling coil of Refrigerator capacity 280/310 ltr of any make/model, complete all as specified and as directed.
Supply and replacing Thermostatic switch of Refrigerator capacity upto 210/310 ltr of any make/model, complete all as specified.
Supply and replacing starting relay of Refrigerator capacity 280/310 ltr of any make/model, complete all as specified and as directed.
Supply and replacing starting relay of deep freezer capacity 320/405 ltr of any make/model, complete all as specified and as directed.
Supply and replacing over load relay of Refrigerator capacity 210/230 ltr of any make/model, complete all as specified and as directed.
Supply and replacing over load relay of Refrigerator capacity 300/310 ltrs of any make/model, complete all as specified and as directed.
Supply and replacing over load relay of water cooler capacity 40/80 ltr of any make/model, complete all as specified and as directed.
Supply & fixing in repairs water cooler tap complete all as specified and as directed.
Supply and fix in repairs brass service valve 1/2" dia complete all as specified and directed.
Supply and fix in repairs brass service valve 1/4" dia complete all as specified and directed.
Supply and fix in repairs copper pipe 1/2" dia complete for split ACs complete all as specified and as directed.
Supply and fix in repairs copper pipe 1/4" dia complete for split Acs complete all as specified and as directed.
S&F sub main wiring with two single core 4.0 Sqmm (nominal area) PVC insulated and unsheathed cables with stranded copper conductor (FRLS) including two run of continuous PVC insulated FRLS copper stranded cable of size 1.5 Sqmm for earth continuity in and including surface/recessed in PVC casing capping, including dismantling & taking down existing wire with accessories, complete all as specified and directed. Notes:- 2 runs of 4.0 Sqmm main cable+1 run of 1.5 Sqmm earth cable+PVC conduit considered as 1 Running Metre.
Supply and fixing, in repairs factory made sheet metal enclosure single pole & neutral with a two pin & earth plug and socket of 20 Amps capacity complete all as specified and directed.
Disconnecting out door type split unit of 1.5/2 TR capacity and refixing the same with supply and fixing new mounting bracket made out of 50x50x6 mm thick angle iron frame including PCC and masonry work, reconnecting the copper pipe with new insulation to the indoor and outdoor unit and testing complete all as specified and directed.
S&F in repairs, insulation tube (size 1/4"/1/2") for split type AC to insulation copper pipe complete all as specified and directed.
Schedule of Credit
M/s PRABIR ENTERPRISE
STANDARD ELECTRIC WINDERS
M/s HALDER ENTERPRISE
M/S K S Enterprise
NChetia and Sons Trading
MAA COMMUNICATION
M/S R G Construction
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .