Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.6 CrAccepted-AOC 112 281 GOPALA KRITI APARTMENT FLAT NO 104 1ST FLOOR SWAROOP NAGAR KANPUR 208 002 | KANPUR NAGAR | UTTAR PRADESH | 208002 | ₹31.6 Cr Quoted ₹31.9 Cr | L1 | Accepted-AOC BEING THE LOWEST BIDDER |
| 2 | L2₹37.4 CrRejected-Finance | ₹37.4 Cr | L2 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
| 3 | L3₹40.9 CrRejected-Finance | ₹40.9 Cr | L3 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
| 4 | L4₹43.9 CrRejected-Finance | ₹43.9 Cr | L4 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
| 5 | L5₹45.3 CrRejected-Finance PLOT NO 65 SECTOR 18 OPP HIPA SARHAUL GURUGRAM 122 001 | ₹45.3 Cr | L5 | Rejected-Finance BEING OTHER THAN THE LOWEST BIDDER |
Tender Value
₹31.1 Cr
EMD Value
₹15 L
Closing Date
10 Apr 2025, 6:00 pmClosed
Chief Engineer(AF) Nagpur
HQ Chief Engineer(AF) Nagpur, Vayusena Nagar, Nagpur - 440007
PROVISION OF ACCIDENTAL BUILDING AND EMERGENCY DEPARTMENT AND CRITICAL CARE OPERATION THEATRE COMPLEX AT KANPUR
2024_MES_660804_4
AF_CHK_801223
Open Tender
Civil Works
750 days
CHAKERI
For MES Enlisted Contractors- Class SS Category a (i) For other Contractor meeting enlistment Criteria of MES for Class SS Category a (i)
8 documents required · 8 mandatory
₹3,000
GE AF BR CHAKERI
₹15 L
Yes
3 Jun 2025
9 Jan 2025
17 Apr 2025
15 Mar 2025
10 Apr 2025
3 Apr 2025
9 Jan 2025 - 16 Jan 2025
Amount
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
Blank
SCH 'A' PART XX (MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Schedule 'A' Part-II.
INTERNAL WATER SUPPLY
Supply and fixing angle valve of cast copper alloy chromium plated with crutch or butterfly handle ,screwed down, for iron pipe or for brass ferrule and fixed 15mm bore complete all as specified and as directed.
Supply and fixing PVC connection 15mm,450mm long with CP nuts complete all as specified and as directed.
Supply and fixing urinal spreader of CP any colour for fixing with 15mm dia pipe complete all as specified and as directed.
Supply and fixing foot operated pillar cock cast copper alloy chromium plated high pressure , at floor level complete all as specified and as directed.
INTERNAL ELECTRIFICATION
Supply and fixing switch modular type,2 module, 20 A DP Switch with indicator 230 volts one way complete all as specified and directed. ( For Acs)
supply and fixing modular type TV socket single outlet,1module complete all as specified and directed.
Supply and fix Vertical TPN distribution board (DB), double door type, as per as per IS 8623- 1 & 3 / IEC 61439- 1 & 3. made out of sheet metal enclosure (CRCA sheet) dust and vermin proof , TPN 4 way with MCCB as incomer,suitableAmps rated copper busbar, 415 Volts suitable for TPN MCB/ 4 pole Isolator, 2 neutral bar and 2 earth bar and blanking plates, IP 54 protection, IK 09 impact resistance, with detachable gland plate, terminal connectors and other required hardware & fasteners cable ties for cable management(Fully insulated busbar and shrouded neutral bars),reversible door for IP 43 & IP 54 ,flush mounted to wall complete.DB shall be designed with provision for MCCB as incomer & SP / SPN MCB as outgoing as per requirement. Cost of the DBs will be without MCB/ MCCB cpmplete all as specified and as directed. Note : Rates are inclusive for flush(Concealed ) mounting of Vertical DB TPN .
Supply and fix Vertical TPN distribution board (DB), double door type, as per as per IS 8623- 1 & 3 / IEC 61439- 1 & 3. made out of sheet metal enclosure (CRCA sheet) dust and vermin proof , TPN 8 way with MCCB as incomer,suitableAmps rated copper busbar, 415 Volts suitable for TPN MCB/ 4 pole Isolator, 2 neutral bar and 2 earth bar and blanking plates, IP 54 protection,IK 09 impact resistance, with detachable gland plate, terminal connectors and other required hardware & fasteners cable ties for cable management(Fully insulated busbar and shrouded neutral bars),reversible door for IP 43 & IP 54 ,flush mounted to wall complete.DB shall be designed with provision for MCCB as incomer & SP / SPN MCB as outgoing as per requirement. Cost of the DBs will be without MCB/ MCCB cpmplete all as specified and as directed. Note : Rates are inclusive for flush(Concealed ) mounting of Vertical DB TPN .
Supply and Fix 4 way Per Phase Isolation (PPI) DB suitable to mount 2 pole residual current device at an individual phase level to isolate the faulty phase in case of earth leakage and ensure continuity of supply to other healthy phases ,with appropriate Amps rated copper busbar, neutral bar, internal earth bar and cable ties for cable management,reversible door for for IP 43 & IP 54, IK 09 impact resistance,single earth connection,flush to wall,ncluding chases cutting in wall for fixing DB and making good distributed wall surfaces to match with existing specification. Suitable for mounting of ELCB/RCCB/MCB,confirming to IS 8623(part-II) complete with Incomer(FP MCB/100A MCCB)+ sub incomer(DP RCCB/RCBO) and SP MCB as outgoing.Cost of the DBs will be without MCBs copmplete all as specified and as directed(8+6+12) Note - Rates are inclusive for flush(Concealed ) mounting of PPI DB .
Supply and Fix 6 way Per Phase Isolation (PPI) DB suitable to mount 2 pole residaul current device at an individual phase level to isolate the faulty phase in case of earth leakage and ensure continuity of supply to other healthy phases ,with appropriate Amps rated copper busbar, neutral bar, internal earth bar and cable ties for cable management,reversible door for for IP 43 & IP 54, IK 09 impact resistance,single earth connection,flush to wall,ncluding chases cutting in wall for fixing DB and making good distributed wall surfaces to match with existing specification. Suitable for mounting of ELCB/RCCB/MCB,confirming to IS 8623(part-II) complete with Incomer(FP MCB/100A MCCB)+ sub incomer(DP RCCB/RCBO) and SP MCB as outgoing.Cost of the DBs will be without MCBs copmplete all as specified and as directed(8+6+18) Note - Rates are inclusive for flush(Concealed ) mounting of PPI DB .
Supply and Fix distribution board (DB), double door (CRCA sheet) dust and vermin proof SPN 6 way with appropriate Amps rated copper busbar, neutral bar,internal earth bar and cable ties for cable management,reversible door for for IP 43 & IP 54, IK 09 impact resistance, single pole and neutral 250 Volts, flush to wall including chases cutting in wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.DB shall be designed with provision for MCB SPN as incomer & MCB SP as outgoing as per requirement. Cost of the DBs will be without MCBs complete all as specified and as directed Note - Rates are inclusive for flush(Concealed ) mounting of DB SPN .
Supply,install,testing and commissioning of 2 pole RCCB 16A/25A in accordance with IS 12640-1 & IEC 61008-1) 240 V/415 V, 50 Hz with 10 kA short circuit withstand capacity,electromagnetic type with 30mA/100mA sensitivity with earth leakage trip indication complete all as specified and directed.
Supply,install,testing and commissioning of 4 pole RCBO 16A to 32A in accordance with IS 12640-1 & IEC 61008-1) 240 V/415 V, 50 Hz with 10 kA short circuit withstand capacity,with overcurrent and earth leakage protection,electromagnetic type with 30mA/100mA/300mA sensitivity with short circuit and earth leakage trip indication complete all as specified and directed.
Supply,install,testing and commissioning of 4 pole RCBO 40A in accordance with IS 12640-1 & IEC 61008-1) 240 V/415 V, 50 Hz with 10 kA short circuit withstand capacity,with overcurrent and earth leakage protection,electromagnetic type with 30mA/100mA/300mA sensitivity with short circuit and earth leakage trip indication complete all as specified and directed.
Supply and fixing LED luminaire square 200 mm x 200 mm panel ,20watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size having CRCA powder coating/aluminium housing,polystyrene diffuser ,Color temperature 6500 K or as directed CRI between 80-85, low THD, PF-0.9(minimum) ,efficacy not less than 110 lumen/watt or total lumen output not less than 2750 lumen per 20 watt, operating range 120-270V ,surge protection of 2 kV over voltage protection and other safety tests as per IS 15885 Part-2/Part-3 ,estimated life span of 50,000 hrs with all accessories, complete with fixing arrangement, fitting shall be internally prewired and conforming to LM 79 & LM 80 standard, havingmounting arrangement with board for surface type or spring loaded mounting clips, making all connection using 1.5 sqmm copper conductor multistrand PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through PVC flexible conduit complete fixed in position & connecting complete all as specified and directed by Engr–in-charge. (Note:(i) LED fitting shall be provided for 3 years warranty. (ii) Location for Installation of LED fitting shall be as per approved drawing)
Supply and fixing LED lamp (RED + GREEN LIGHT),0.50watt, B22 Base Cap,220 V AC complete with holders & LED lamp suitable for wall fitting including connecting up flexible copper conductor cable , complete with fixing arrangement, all as specified and directed by Engr–in-charge. (Note:(i) Location for Installation of LED fitting shall be as per approved drawing)
Supply and fixing LED lamp (Night Lamp) Warm white,0.50watt, B22 Base Cap, 220 V AC complete , operating range 140-260V , complete with wooden/PVC block fixing arrangement,& connecting complete all as specified and directed by Engr–in-charge. (Note:(i) Location for Installation of LED fitting shall be as per approved drawing.
Supply and fixing decorative , wall mounting, brushed nickel finish fixture with acrylic diffuser suitable with 9 W LED lamp B22 base ,220 V AC complete , complete with 9 W LED lamp B22 with lumen output 945 lumen, operating range 140-260V,lamp tested for estimated life span of 25,000 hrs,suitable fixing arrangement and connecting complete all as specified and directed by Engr–in-charge Note:(i) Location for Installation of LED fitting shall be as per user requirement.
Supply and fix LED Reading light /Bed side light 3watt aluminium, with built in LED suitable for 220 -240volts, 50hz supply dust and water resistant , total lumen output fixture 150lm/watt efficacy ,tested for estimated life span of minimum 25000 working hours ,CRI 80, light colour temperature 2700 - 5000 CCT or as per requirement,Class II IP 20 suitable fixing arrangement and connecting complete all as specified and directed by Engr–in-charge Note:(i) ) Location for Installation of LED fitting shall be as per user requirement)
Supply,install,testing,connecting and commissioning complete wall mounting fan 400mm sweep, with three motor speeds facility,Oscilatting 160° ,1360 RPM, air delivery 72cum/min, noise level 62db, suitable for 230V , 50 Hz AC supply, suitable fixing arrangement and connecting complete all as specified and directed by Engr–in-charge Note:(i) Location for Installation of WALL FAN shall be as per drawings/user requirement.
Supply and fix integrated LED and battery emergency light rechargeable 4 watt, Lithium ion battery for long life ,of size 6.5 cm(height) x 69 cm(Length) X 6.5 cm(width),White Color rendering index (CRI) 80, suitable for 220-240 V 50 Hz AC supply,Class II IP 20,suitable for horizontal/vertical mounting on wall/ceiling withOvercharge & deep discharge protection.complete with clamp and fixing arrangement and connecting complete all as specified and directed by Engr–in-charge Note:(i) Location for Installation of Emergency light shall be as per user requirement
Supply,Install,testing,connecting and commissioning Emergency Light LED Exit Sign, Emergency Razor with Down/Up/Left/Right legend, 2.2 W, 19 lm, 7000 K, Clear,Finger-protected with driver,Luminous Flux 19 lm Luminous Efficacy (rated) (Nom) 23.7 lm/W,CRI 70 Correlated Color Temperature (Nom) 7000 K,Light source color 765 cool daylight,Ingress protection code IP20 (Finger-protected),Mech. impact protection code IK03 (0.3 J), AcrylateOptical cover,Dimensions (Height x Width x Depth) 212 x 42 x 313 mm suitable to perform under ambient temperature of 25 °C complete with clamp and fixing arrangement and connecting complete all as specified and directed by Engr–in-charge Note:(i) Location for Installation of Emergency exit sign light shall be as per user requirement
Design, Supply, Install, Testing ,Commissioning of all Nurse Calling System complete with all items mentioned but not limited to below , In general the complete system design and installations shall confirm to latest guidelines and the specifications. Note : All Equipment items for Nurse call System shall be according to requirement of user. (a) Nurse Station Console Unit Addressable Microprocessor Control Nurses Call Station Monitor with built?in 7 Segment LED and a soft buzzer. Information displayed in 5 digit, when more then one call is registered, then the information shall be scrolled. Power supply suitable for 220 volts 50 hz AC main supply complete with step-down transformer of appropriate rating , electronic rectifier with regulating circuits to give two numbers of DC outputs of + 12V DC through battery/panel and battery charger , all housed in powder coated sheet steel enclosure ,network interface module, power supply and complete as per specification required. The Staff Console shall have a 7" capacitive touch backlit color LCD screen
(b) Nurse call Bed unit : Supply, Installation, Testing & Commissioning of Bedside modules comprising of Nurse call, cancel & Wait,Code blue buttons hand held unit and input jack for hand held module including providing and fixing of 1.6 mm thick GI box complete as per specifications
(c) Nurse call Bed unit : Supply, Installation, Testing & Commissioning of Bedside modules comprising of Code blue Module including providing and fixing of 1.6 mm thick GI box complete as per specifications.
(d) Toilet unit: Supply, Installation, Testing & Commissioning of Emergency Switch a near WC including providing and fixing of GI box complete with all accessories and as per specifications
(d) Door display unit : Supply, Installation, Testing & Commissioning of Door Display Unit(corridor indicator module) with acrylic cover & indicator lamp & 1.6mm thick GI box & with all accessories and as per specifications
Supply and Fix UTP cat 6 cable including LMS PVC FRLS conduit 20mm diacomplete with all accessories when burried in wall with wall chasing & finishing i.e. bends, junction boxes, outlet boxes with cover plates of approved make and as per design specifications
Supply, laying, Testing & Commissioning of 4 pair UTP cat 6 cable including LMS PVC FRLS conduit 20mm dia complete with all accessories when burried in wall with wall chasing & finishing i.e. bends, junction boxes, outlet boxes with cover plates of approved make and as per design specifications.also it includes all the accesories like controller etc. (for Patient Monitoring System)
Supply, Installation, Testing and Commissioning of necessary software for Nurse calling system.complete all as specified and as directed.
Supply, laying, testing and commissioning of cabling with brass compression gland for PVC Insulated(Inner and outer sheath FRLS) wire armoured copper conductor cable of 600/1100 Volts grade Grade as per IS 7098 (Part 1) 1988 of size 2.5Sq.mm x 3 core steel wire armoured cable annealed tinned multi strand copper conductor in MS conduit as required.all as specified and as directed
Supply and Fix modular type computer jack RJ 45 with safety shutter duly erected on provided plate and box with wiring connections for LAN connectivity, complete all as specified and directed.
Supply and fixing LED recessed luminaire downlighter 220mm dia.switchable ,38watt, 220 V AC recessed type light distribution downlighting wide flood, g Spherolit lenses,CRI >80,Low THD,PF >0.95,with anti glare cone complete with driver, holders & LED lamp suitable for false/ roof ceiling including connecting up with driver three core flexible copper conductor cable of suitable size having CRCA powder coating/aluminium housing,Color temperature 4000 K or as directed,efficacy not less than 130 lumen/watt or total lumen output not less than 4920lumen per 38 watt, operating range 120-270V , protection class 1 as per IEC 61140 surge protection of 2 kV, over voltage protection, short circuit and open circuit protection and other safety tests as per IS 15885 Part-2/Part-3,estimated life span of 50,000 hrs with all accessories, complete with fixing arrangement, fitting shall be internally prewired and conforming to LM 79 & LM 80 standard, having mounting arrangement with board for surface type or spring loaded mounting clips, making all connection using 1.5 sqmm copper conductor multistrand PVC insulated 3 core flexible cable from ceiling rose to fitting drawn through PVC flexible conduit complete fixed in position & connecting complete all as specified and directed by Engr–in-charge. (Location : Atrium .However contractor shall verify location for Installation of LED fitting as per approved drawing)
Supply and Fix modular type telephone jack RJ 11 with safety shutter duly erected on provided plate and box complete all as specified and directed.
Supply and Fix UTP cat 6 cable for networking including LMS PVC FRLS conduit 20mm dia complete with all accessories when burried in wall with wall chasing & finishing i.e. bends, junction boxes, outlet boxes with cover plates of approved make and as per design specifications for LAN connectivity , complete all as specified and as directed.
EXTERNAL WATER SUPPLY
Material and labour for boring of holes under road, pavement, runway, taxi track, hard standing by trenchless technolgy using ultrasound technique and necessary machine including HDPE pipe of 150 mm nominal dia PE 80 grade 0.4 Mpa working pressure for cable/pipe protection complete all as directed. Note: HDPE pipe shall be laid minimum 90 cm below the surface. complete all as specified and as directed.
Material and labour for drilling and tapping cast iron water mains of any size for provision of branch connection and fixing of fittings such as staright plain brass ferrules( or connecting screws) screwed both ends and fixed of size 40mm with internal dia 40mm complete all as specified and directed.
Material and labour for construction of valve chamber of size 900x 900 x 900 mm deep dimensions (Over all internal dimension) with PCC foundation, random rubble uncoarsed brick masonry walls, Plastering, PCC Coping, white washing, mild steel chamber cover, painting to chamber cover including Excavation and earth work in any type of soil complete all as specified below:-Valve chamber shall be provided with the following specifications:- (i) Cement concrete for foundation (1:4:8) type D2 using 40mm graded stone aggregate 150 mm thick extended up to 150 mm beyond the outer face of brick masonry.(ii) Walls of valve chamber 230 mm thick with precast cement concrete (1:5:8) (using 20mm graded stone aggregate) using brick masonary setting in CM 1:6 complete. (iii) Internal and exposed surfaces of valve chamber both concrete and brick masonry surface shall be plastered with CM (1:4), 15 mm thick finished even and smooth.(iv) 50 mm thick coping in PCC 1:3:6 type C1 over brick masonry wall.(v) Entire plastered surfaces shall be treated with 3 coat of white wash.(vi) Chamber cover shall be of 6 mm thick MS sheet with 40 x 40 x 6 mm size angle iron frame with hold fast and locking arrangement. Steel surface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer complete all as specified and as directed .
Supply, installation, testing and commissioning of LT panel indoor type floor mounted design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections. The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.
Item No.20.039 contd... EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for suitable for motors of chiller unit/cooling tower/and pumps complete as required and comprising of the following:- (A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs .
Material and labour for making connection from existing 100 /150 mm bore CI / GI water pipe line by providing mild steel two piece half round clamp fabricated with 60 mm wide & 5 mm thick mild steel flat bend to shape welding 40 mm size socket, including nut bolt, rubber packing, drilling hole in existing pipe line & painting of clamp with anti corrosive paint and including necessary earthwork excavation etc as specified and directed .
Supply and fixing for forged brass Air release valve 25mm , Chrome plated forged brass body and cover , Kinetic type non clogging & self sealing balls for trouble free operation, totally tamper proof Ideally suited for turbid or clear water conforming to IS:14845/AWWA pressure rating PN 1.6 and jointing materials like gaskets, flanges , nuts and bolts and wahser etc complete for fixing arrangement in water pipes mains complete all as specified and as directed
EXTERNAL ELECTRIFICATION
Supply, installation, testing and commissioning of LT panel indoor type floor mounted ( Main Panel, Location : Sub Station Room) cubical type BMS compatible design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, fully interlocked electrically and mechanically, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 150mmX 100mmX 5 mm thick, fabrication shall be done in transportable sections.
Item No. 20.042 contd The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 75x75x6mm or suitable size duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for suitable for eletric load complete as required and comprising of the following:- (A). TRANSFORMER - I INCOMER (i) ACB 1250 A, 4P, 415V, 50kA , lcs =100% lcu confirm to IEC/IS – 60947-2, with microprocessor based adjustable overload 50-100%, adjustable short circuit in range of 400% to 100% of ACB rating and earth fault protection have adjustable current setting of 20% to 100% of rated capacity complete with with integral LCD Display of load current and individual loading of all the three phases including closing and trip coils (Shunt release + Under voltage release) and protection against , over current, short circuit,over voltage and earth fault.ACB shall be electronic draw out type modular in construction confirming to IEC947/IS:13947(part 2) ,VDE 0660 Part 101,IEC 68 Part 2-30(Climate proof).
Item No. 20.042…. contd The ACB release shall be self powered with true RMS sensing. The ACB shall be with 230 V AC shunt trip coil and 230 V, AC Motor wound spring closing mechanism.Specific LED indications should be provided for short circuit, over current and earth fault operation for faster fault diagnosis - 01 nos (ii) Surge arrester 2kVp,75kA rated surge arrestor suitable fo both lightning and switching surges,complete with suitable protection fuse (inbuilt) along with 250A, 36kA, FP, MCCB (Thermal magnetic based) and surge counter- 1 No (iii) 1- set Red/Green ON/OFF indicating lamps (iv) 1- set of three phase (red, yellow, blue) indicating lamps (v) Amber healthy trip indicating lamps (vi)3 nos. cast resin current transformers of 1250/5 ratio with 15 VA Burden & Class 5P10 for protection and Class 1.0 for measurement or CTs of suitable capacity as per panel designer. (vii) RS-485 port for display of ON/OFF status, current and energy parameters etc. of ACB on BMS workstation through MODBUS protocol (viii) Terminals to receive alum. XLPE armoured cables. Note: Contractor shall provide an earmarked terminal boards for SCADA signals as per specification & requrments.
Item No. 20.042.. contd (B). TRANSFORMER - II INCOMER (i) ACB 1250 A, 4P, 415V, 50kA , lcs =100% lcu confirm to IEC/IS – 60947-2, with microprocessor based adjustable overload 50-100%, adjustable short circuit in range of 400% to 100% of ACB rating and earth fault protection have adjustable current setting of 20% to 100% of rated capacity complete with with integral LCD Display of load current and individual loading of all the three phases including closing and trip coils (Shunt release + Under voltage release) and protection against , over current, short circuit,over voltage and earth fault.ACB shall be electronic draw out type modular in construction confirming to IEC947/IS:13947(part 2) ,VDE 0660 Part 101,IEC 68 Part 2-30(Climate proof).The ACB release shall be self powered with true RMS sensing. The ACB shall be with 230 V AC shunt trip coil and 230 V, AC Motor wound spring closing mechanism.Specific LED indications should be provided for short circuit, over current and earth fault operation for faster fault diagnosis - 01 nos (ii) Surge arrester 2kVp,75kA rated surge arrestor suitable fo both lightning and switching surges,complete with suitable protection fuse (inbuilt) along with 250A, 36kA, FP, MCCB (Thermal magnetic based) and surge counter- 1 No
Item No. 20.042... contd (iii) 1- set Red/Green ON/OFF indicating lamps (iv) 1- set of three phase (red, yellow, blue) indicating lamps (v) Amber healthy trip indicating lamps (vi)3 nos. cast resin current transformers of 1250/5 ratio with 15 VA Burden & Class 5P10 for protection and Class 1.0 for measurement or CTs of suitable capacity as per panel designer. (vii) RS-485 port for display of ON/OFF status, current and energy parameters etc. of ACB on BMS workstation through MODBUS protocol (viii) Terminals to receive alum. XLPE armoured cables. Note: Contractor shall provide an earmarked terminal boards for SCADA signals as per specification & requrments. Note: Contractor shall provide an earmarked terminal boards for SCADA signals as per specification & requrments. (C). BUS COUPLER (i) ACB 1250 A, 3P, 415V, 50kA , lcs =100% lcu confirm to IEC/IS – 60947-2, with microprocessor based adjustable overload 50-100%, adjustable short circuit in range of 400% to 100% of ACB rating complete with ON/OFF indication and earth fault protection have adjustable current setting of 20% to 100% of rated capacity complete with with integral LCD Display of load current and individual loading of all the three phases including closing and trip coils (Shunt release + Under voltage release) and protection against , over current, short circuit,over voltage and earth fault.ACB shall be electronic draw out type modular in construction confirming to IEC947/IS:13947(part 2) ,VDE 0660 Part 101,IEC 68 Part 2-30(Climate proof).
Item No. 20.042... contd The ACB release shall be self powered with true RMS sensing. The ACB shall be with 230 V AC shunt trip coil and 230 V, AC Motor wound spring closing mechanism.Specific LED indications should be provided for short circuit, over current and earth fault operation for faster fault diagnosis - 01 nos (ii) 1- set Red/Green ON/OFF indicating lamps (iii) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB/ACB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (iv) Two incomers shall be interlocked electrically & mechanically (v) RS-485 port for display of ON/OFF status, current and energy parameters etc. of ACB on BMS workstation through MODBUS protocol. Note: Contractor shall provide an earmarked terminal boards for SCADA signals as per specification & requrments.
Item No. 20.042... Contd (D).METERING (i) 2 sets (4 no.) of AC operated, 3.5 Digit, independent Digital Ammeter,Digital Volt meter with necessary Circuit MCBs and with suitable size CTs connections as required for incoming feeders (ii) 2 No., 230V, AC operated integral type Digital meter with RS-485 port for measuring Amps ,Voltage, Energy, kWH, kVAH, frequency,Maximum Demand & power factor etc with TOD facility conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCBs and suitable size summating CTs for above two incomer metering supporting SCADA/BMS connectivity. (iii) MCB SP 6A 'C' series for control ckt protection = 06Nos (E). OUTGOING FROM TRANSFORMER -I (a) Central A/C Plant : (i) ACB 1000 A, 4P, 415V, 50kA , lcs =100% lcu confirm to IEC/IS – 60947-2, with microprocessor based adjustable overload 50-100%, adjustable short circuit in range of 400% to 100% of ACB rating and earth fault protection have adjustable current setting of 20% to 100% of rated capacity complete with with integral LCD Display of load current and individual loading of all the three phases including closing and trip coils (Shunt release + Under voltage release) and protection against , over current, shor circuit,over voltage and earth fauly.ACB shall be electronic draw out type modular in construction confirming to IEC947/IS:13947(part 2) ,VDE 0660 Part 101,IEC 68 Part 2-30(Climate proof).The ACB release shall be self powered with true RMS sensing. The ACB shall be with 230 V AC shunt trip coil and 230 V, AC Motor wound spring closing mechanism.Specific LED indications should be provided for short circuit, over current and earth fault operation for faster fault diagnosis - 01 nos
Item No. 20.042... Contd (b) FireFighting Pump House : (i) MCCB 400 Amp 4 pole, 36 KA, lcs =100% lcu, microprocessor release ,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) Adjustable Overload, Short-circuit, Ground fault (4 Pole) & Fixed Instantanous Netural Protection (4 Pole), adjustable overload release 70% to100% and adjustable short circuit release from up to 10 ln setting complete with phase seperator - 02 Nos(1W + 1 standby) (c ) Street Light : (i) MCCB 40 Amp 4 pole, 16 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator -01 nos (d) Solar Water Heater backup,Fire alarm and BMS : (i) MCCB 63 Amp 4 pole, 25 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator - 04 nos. (3W + 1 standby) (e) Lift : (i) MCCB 160 Amp 4 pole, 36 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with adjutsable magnetic and adjustable thermal release, adjustable overload 65% to100% and adjustable short circuit release from 3.5 to10 ln setting complete with phase seperator - 01 Nos
Item No. 20.042.. Contd (f) MGPS pump house : (i) MCCB 200 Amp 4 pole, 36 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with adjutsable magnetic and adjustable thermal release, adjustable overload 65% to100% and adjustable short circuit release from 3.5 to10 ln setting complete with phase seperator - 02 Nos(01 nos working + 01 nos Stand by) (F). OUTGOING FROM TRANSFORMER II (a) Main UPS Panel (i) MCCB 400 Amp 4 pole, 50 KA, lcs =100% lcu, microprocessor release ,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) Adjustable Overload, Short-circuit, Ground fault (4 Pole) & Fixed Instantanous Netural Protection (4 Pole), adjustable overload release 70% to100% and adjustable short circuit release from up to 10 ln setting complete with phase seperator - 02 Nos(1W + 1 standby) (b) APFC Panel : (i) MCCB 630 Amp 4 pole, 50 KA, lcs =100% lcu, microprocessor release ,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) Adjustable Overload, Short-circuit, Ground fault (4 Pole) & Fixed Instantanous Netural Protection (4 Pole), adjustable overload release 70% to100% and adjustable short circuit release from up to 10 ln setting complete with phase seperator - 02 Nos
Supply, installation, testing and commissioning of LT panel indoor type floor mounted ( Main Panel for Lighting , Power and Hospital Equipment Location : Panel Room at individual Floor) cubical type BMS compatible design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, fully interlocked electrically and mechanically, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 100mmX 50mm X 5 mm thick, fabrication shall be done in transportable sections. The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm.
Item No.20.043... Contd The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for suitable for eletric load complete as required and comprising of the following:-
Item No.20.043... Contd (A). INCOMER (i) MCCB 350 Amp 4 pole, 36 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with adjutsable magnetic and adjustable thermal release, adjustable overload 65% to100% and adjustable short circuit release from 3.5 to10 ln setting complete with phase seperator - 01 Nos (ii) 1 No., 230V, AC operated integral type Digital multi function meter with RS-485 port for measuring Amps ,Voltage, Energy, kWH, kVAH, frequency,Maximum Demand & power factor etc with TOD facility conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCBs and suitable size summating CTs for incomer metering supporting SCADA/BMS connectivity. (iii) 1- set Red/Green ON/OFF indicating lamps (iv) 1- set of three phase (red, yellow, blue) indicating lamps (v) Amber healthy trip indicating lamps (vi)3 nos. cast resin current transformers of suitable ratio with VA Burden & protection and Class 1.0 for measurement or CTs of suitable capacity as per panel designer. (vii) RS-485 port for display of ON/OFF status, current and energy parameters etc. of ACB on BMS workstation through MODBUS protocol (viii) Terminals to receive alum. XLPE armoured cables.(ix) MCB SP 6A 'C' series for control ckt protection = 03Nos
Item No.20.043... contd (B). BUSBAR (i) TPN + E Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB/ACB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs. (C). OUTGOING (i) MCCB 160 Amp 4 pole, 36 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with adjutsable magnetic and adjustable thermal release, adjustable overload 65% to100% and adjustable short circuit release from 3.5 to10 ln setting complete with phase seperator - 02 nos ( 01 working + 01 standby) ( Medical Equipment)
Supply, installation, testing and commissioning of LT panel indoor type floor mounted ( Sub Panel for Lighting & Power) (Location : Panel Room at individual Floor) cubical type BMS compatible design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, fully interlocked electrically and mechanically, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 75mmX 50mm X 5 mm thick, fabrication shall be done in transportable sections. The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.
Item No.20.044... contd Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for suitable for eletric load complete as required and comprising of the following:- (A). INCOMER (i) MCCB 125 Amp 4 pole, 25 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator - 01 nos. (ii) 1 No., 230V, AC operated integral type Digital multi function meter with RS-485 port for measuring Amps ,Voltage, Energy, kWH, kVAH, frequency,Maximum Demand & power factor etc with TOD facility conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCBs and suitable size summating CTs for incomer metering supporting SCADA/BMS connectivity.
Item No.20.044... contd (iii) 1- set Red/Green ON/OFF indicating lamps (iv) 1- set of three phase (red, yellow, blue) indicating lamps (v) Amber healthy trip indicating lamps (vi)3 nos. cast resin current transformers of suitable ratio with VA Burden & protection and Class 1.0 for measurement or CTs of suitable capacity as per panel designer. (vii) RS-485 port for display of ON/OFF status, current and energy parameters etc. of ACB on BMS workstation through MODBUS protocol (viii) Terminals to receive alum. XLPE armoured cables.(ix) MCB SP 6A 'C' series for control ckt protection = 03Nos (B). BUSBAR (i) TPN + E Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB/ACB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs. (C). OUTGOING (i) MCCB 63 Amp 4 pole, 25 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator - 02 nos ( 01 working + 01 standby)
Supply, installation, testing and commissioning of LT panel indoor type floor mounted ( Sub Panel for Medical Equipment) (Location : Panel Room at individual Floor) cubical type BMS compatible design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, fully interlocked electrically and mechanically, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 75mmX 50mm X 5 mm thick, fabrication shall be done in transportable sections. The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm.
Item No.20.045... contd The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for suitable for eletric load complete as required and comprising of the following:- (A). INCOMER (i) MCCB 160 Amp 4 pole, 36 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with adjustable magnetic and adjustable thermal release, adjustable overload 65% to100% and adjustable short circuit release from 3.5 to10 ln setting complete with phase seperator - 01 Nos (ii) 1 No., 230V, AC operated integral type Digital multi function meter with RS-485 port for measuring Amps ,Voltage, Energy, kWH, kVAH, frequency,Maximum Demand & power factor etc with TOD facility conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCBs and suitable size summating CTs for incomer metering supporting SCADA/BMS connectivity.
Item No.20.045... contd (iii) 1- set Red/Green ON/OFF indicating lamps (iv) 1- set of three phase (red, yellow, blue) indicating lamps (v) Amber healthy trip indicating lamps (vi)3 nos. cast resin current transformers of suitable ratio with VA Burden & protection and Class 1.0 for measurement or CTs of suitable capacity as per panel designer. (vii) RS-485 port for display of ON/OFF status, current and energy parameters etc. of ACB on BMS workstation through MODBUS protocol (viii) Terminals to receive alum. XLPE armoured cables.(ix) MCB SP 6A 'C' series for control ckt protection = 03Nos (B). BUSBAR (i) TPN + E Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB/ACB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs.
Supply, installation, testing and commissioning of LT panel indoor type floor mounted ( Sub Panel for Non critical Load) (Location : Panel Room at individual Floor) cubical type BMS compatible design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, fully interlocked electrically and mechanically, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 75mmX 50mm X 5 mm thick, fabrication shall be done in transportable sections. The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm.
Item No.20.046... contd The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for suitable for eletric load complete as required and comprising of the following:- (A). INCOMER (i) MCCB 100 Amp 4 pole, 25 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator - 01 nos.
Item No.20.046... contd (ii) 1 No., 230V, AC operated integral type Digital multi function meter with RS-485 port for measuring Amps ,Voltage, Energy, kWH, kVAH, (iii) 1- set Red/Green ON/OFF indicating lamps (iv) 1- set of three phase (red, yellow, blue) indicating lamps (v) Amber healthy trip indicating lamps (vi)3 nos. cast resin current transformers of suitable ratio with VA Burden & protection and Class 1.0 for measurement or CTs of suitable capacity as per panel designer. (vii) RS-485 port for display of ON/OFF status, current and energy parameters etc. of ACB on BMS workstation through MODBUS protocol (viii) Terminals to receive alum. XLPE armoured cables.(ix) MCB SP 6A 'C' series for control ckt protection = 03Nos (B). BUSBAR (i) TPN + E Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB/ACB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs.
Supply, installation, testing and commissioning of LT panel indoor type floor mounted ( Incomer - outgoing to stabilizer) (Location : Sub station) design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, fully interlocked electrically and mechanically, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 100mmX75mm X 5 mm thick, fabrication shall be done in transportable sections. The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.
Item No.20.047... contd EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 50x50x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for suitable for eletric load complete as required and comprising of the following:- (A). INCOMER CUM OUTGOING (i) ACB 1250 A, 4P, 415V, 50kA , lcs =100% lcu confirm to IEC/IS – 60947-2, with microprocessor based adjustable overload 50-100%, adjustable short circuit in range of 400% to 100% of ACB rating complete with ON/OFF indication and earth fault protection have adjustable current setting of 20% to 100% of rated capacity complete with with integral LCD Display of load current and individual loading of all the three phases including closing and trip coils (Shunt release + Under voltage release) and protection against , over current, short circuit,over voltage and earth fault.ACB shall be electronic draw out type modular in construction confirming to IEC947/IS:13947(part 2) ,VDE 0660 Part 101,IEC 68 Part 2-30(Climate proof).The ACB release shall be self powered with true RMS sensing. The ACB shall be with 230 V AC shunt trip coil and 230 V, AC Motor wound spring closing mechanism.Specific LED indications should be provided for short circuit, over current and earth fault operation for faster fault diagnosis - 02 nos
Item No.20.047... contd (ii) 2 No., 230V, AC operated integral type Digital multi function meter with RS-485 port for measuring Amps ,Voltage, Energy, kWH, kVAH, frequency,Maximum Demand & power factor etc with TOD facility conforming to specifications, latest IEC/ EMC and EMI standards/criterion, with necessary Circuit MCBs and suitable size summating CTs for incomer metering supporting SCADA/BMS connectivity. (iii) 2- set Red/Green ON/OFF indicating lamps (iv) 2- set of three phase (red, yellow, blue) indicating lamps (v) Amber healthy trip indicating lamps (vi) cast resin current transformers of suitable ratio with VA Burden & protection and Class 1.0 for measurement or CTs of suitable capacity as per panel designer. Note: (i) LT panel shall be CPRI approved (ii) Contractor shall submit the following Test report i.e. IP Test Report and verification of short circuit withstand test report to GE (iii) Contractor shall submit GA drawing prior to procurement of LT Panel for approval of GE/CWE.
Supply,laying,jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes/ducts/road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 1.0 core x 400 sqmm confirming to IS - 7098 Part-1 and its latest amendments complete all as specified and as directed by Engr-in-Charge. (2 Run of 1C X 400 sqmm from transformer to Voltage stabilizer )
Supply,laying,jointing and testing, fixing to wall using clamps/pole/floor or in air or passing through pipes/ducts/road/path/drain, laid in trenches, 1100 volts grade heavy duty electric cable XLPE insulated,screened ,PVC bedded, galvanised steel wire or wire armoured with electric power cable 1100 volts grade with stranded aluminium conductor of size 1.0 core x 300 sqmm confirming to IS - 7098 Part-1 and its latest amendments complete all as specified and as directed by Engr-in-Charge. (2 Run of 1C X 300 sqmm from Main Panel to AC plant Panel )
Supply and fixing hot pressed moulded Glass reinforced polyester sheet moulding compound (SMC) Junction box of dimensions 250mm x 200mm x 100mm, SMC confirming to IS: 13410:1992 Grade S 1 ,thickness of SMC sheet not less than 1.5mm, outdoor type, single door hinged with front side opening, weather proof, suitable locking arrangement at front, arrangement for incoming and out going cable entry at the bottom ,earthing arrangement using One no. of Earthing bolt of MS with 2 nuts and 2 washers provided on RH side of box, Earthing sign has to be provided near to earthing bolt complete all as specified and comprising of the followings items as under:- (a) single phase and neutral bus bar duly colour coded of capacity 100 amps using aluminium strips of size 25mm x 4mm mounted on epoxy resin base insulators, drilled holes for cable connection on bus bar including provision of PVC cable of suitable size and length from bus bar to MCB . (b) MCB SP 5 to 32 Amps, - 01 No (c) Provision of clamp for mounting on pole/wall, clamp made from 20mm x 1.5mm flat iron of suitable shape and length duly fixed with nuts & bolts on the rear side of box
Supply and fixing hot pressed moulded Glass reinforced polyester sheet moulding compound (SMC) Junction box of dimensions 225mm x 295mm x 120mm, SMC confirming to IS: 13410:1992 Grade S 1 ,IP 55,thickness of SMC sheet not less than 1.5mm, outdoor type, single door hinged with front side opening, weather proof, suitable locking arrangement at front, arrangement for incoming and out going cable entry at the bottom ,earthing arrangement using One no. of Earthing bolt of MS with 2 nuts and 2 washers provided on RH side of box, Earthing sign has to be provided near to earthing bolt complete all as specified and comprising of the followings items as under:- (a) Three phase and neutral bus bar duly colour coded of capacity 100 amps using aluminium strips of size 25mm x 4mm mounted on epoxy resin base insulators, drilled holes for cable connection on bus bar including provision of PVC cable of suitable size and length from bus bar to MCB, 2 nos cable glands . (b) MCB SPN 16 Amps, - 02 No (c) Provision of clamp for mounting on pole/wall, clamp made from 20mm x 1.5mm flat iron of suitable shape and length duly fixed with nuts & bolts on the rear side of box
Supply and fix CI cable route indicator 150mm dia , 5mm thick duly engraved with " HT 11000 volts" and bolted/welded to MS angle iron of size 40x 40x5 mm,70 cm long,50cm above ground level and 20 cm below ground, painted with 2 coats of synthetic enamel paint using approved colour over a coat of red oxide primer. The route indicator should be grouted in PCC using (1:2:4) type B-1 of size 150x100mm below the ground level complete all as specified and as directed by Engr-in-charge Note:- Route markers are to be fixed at a distance from each other all as directed.
Supply and fix CI cable route indicator 150mm dia , 5mm thick duly engraved with " LT 1100 volts" and bolted/welded to MS angle iron of size 40x 40x5 mm,70 cm long,50cm above ground level and 20 cm below ground, painted with 2 coats of synthetic enamel paint using approved colour over a coat of red oxide primer. The route indicator should be grouted in PCC using (1:2:4) type B-1 of size 150x100mm below the ground level complete all as specified and as directed by Engr-in-charge Note:- Route markers are to be fixed at a distance from each other all as directed.
Material and labour for boring of holes under road, pavement, runway, taxi track, hard standing by trenchless technolgy using ultrasound technique and necessary machine including HDPE pipe of 150 mm nominal dia PE 80 grade 0.4 Mpa working pressure for cable protection complete all as directed. Note: HDPE pipe shall be laid min 90 cm below the surface. complete all as specified and as directed.
Material and labour for Boring of holes not less than 200mm dia under taxi track/road pavement hard standing or in any strata of soil by trenchless technology using ultra sounding latset technique and necessary machinery including provision of HDPE pipe 150mm dia PN 10 up to full length of bore,making good the disturbed surface using PCC work as per site requirement and returning/ refilling of excavated material and removal of surplus soil from site complete all as specified and as directed.
Supply and fixing / passing through pipe from junction box to street light ,1.5sqmm 1100 volts grade heavy duty cable with PVC insulated multistranded copper conductor cableflame retardant low smoke & halogen confirming to 1100volt confirming to IS 694 complete all as specified.
Taking out LT cable any size from trenches/duct , stacking at site , checking by megger and shifting to other site for relaying complete all as specified and directed by Engr-in-Charge.
Taking out HT cable any size from trenches/duct , stacking at site , checking by megger and shifting to other site for relaying complete all as specified and directed by Engr-in-Charge.
Material and labour for relaying of serviceable LT cable of any size in trenches/duct complete all as specified and directed by Engr-in-Charge.
Material and labour for heat shrinkable type straight through joint suitable for cable of size 25 to 120 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
Material and labour for heat shrinkable type straight through joint suitable for cable of size 150 to 400 Sqmm, 3.5 Core, 1100 Volts grade coomplete all as specified and directed.
Material and labour for relaying of serviceable HT cable of any size in trenches/duct complete all as specified and directed by Engr-in-Charge.
Material and labour for disconnecting cable connection of LT panel /Feeder Pillar Box of any size and capacity cleaning thoroughly with vaccum cleaner and CRC and shifting carefully to new location , making cable connection for incoming and out going cables along with required cable glands and lugs and foundation work at new location all as specified and directed.
Material and labour for transportation for shifting of DG Set 62.5 KVA along with connected LT,APFC Panel inluding disconnection & connection of cables from one location to another location with in 7 AFH area and making connections and testing complete all as specified and directed. Note : 1.Safe transportation of transformer for shifting is responsibility of contractor. 2. Prepration of foundation and dismantling of existing foundation is to be done by contractor.
ROAD/PATH/CULVERT
Material and labour for applying thermoplastic reflective paint as in road marking 2 mm thick single coat as in centre line or edge line road marking of n.exc 150 mm width using HOT MARK thermoplastic paint (Hot application) white by indigenous modem propelled road marking method as directed including all ingredients such as binder glass beads Titanium-dioxide calcium carbonate linter fillers including spraying of glass beads instructions complete all as specified and directed.
Material and labour for 150 mm thick pavement quality cement concrete work in pavement / hardstanding of fluxural strength 4.5 Mpa in filed using minimum 400 kg of cement per cubic metre complete all as specified and directed
Supply and fixing for framed doors or gates of mild steel angles or other sections with gusset plates, rails, braces etc., incl 0.6x0.6M RCC Gate Pillers with 1.2 mt below ground level and 3.00 Mt above ground level with 20 mm thick Granite slab over face of gate pillers, complete drilled for fixing of steel sheeting or other covering, doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing of Fe-410W(Gde-E-250) quality 'A', complete all as directed.
LIGHTINING PROTECTION
Supply and Fix epoxy insulator duly coloured with necessary fixing arrangement on wall and roof for fixing of down conductor complete all as specified and as directed
STAND BY DG SET
Supply,install ,testing, commissioning of 'Silent type' diesel generating set alongwith having prime power rating of 600kVA/480 kWe,415Volts at 1500RPM , 0.8 lagging power factor at 415 volts suitable for 50 hz 3 phase system and for 0.85 load factor ,CPCB-II complied, acoustic enclosure, engine is designed to meet stringent exhaust emission tests as per revised MoEF norms, anti vibration mountings,control panel and foundation.The DG set should be robust in construction factory tested and assembled to ensure perfect alignment of Engine and Alternator on a common base frame.The DG set power rating indicated above is inclusive of altitude correction factor however the DGSet shall be designed and suitable to operate as per tropical condition of Chakeri, Kanpur and for more details on service condition refer particualr specification. The DG set shall be Eco-Friendly product complying with CPCB noise and emission norms (noise and emission values lower than CPCB limits) and complying with latest emmission standards issued vide gazatte notification G.S.R. 804(E) by MoEF The DG set shall be comprising of following item as under:-
Item No. 20.069 contd... (a)Diesel Engine : The diesel engine shall be of four stroke cycle multi-cylinder(6 cvlinder in line),direct injection radiator water cooled, turbo charged with after cooler,compression ration 16.7:1, Air to air aftercooling and optimised turbocharger for increased altitude capabilities developing required 708 BHP/528kW @ 1500 rpm ( MoEF Certified Power - 713 bhp) under NTP condition of BS 5514/ISO 3046 with an over load capacity of 110% for one hour in any specified 12 hrs of continuous operation,suitable for generating set application on AMF mode.The engine shall confirm to IS:10000/BS:649/BS 5514/ISO 3046.The engine shall have the following accessories: (i)Cooling fan and radiator.(ii)DM water cooling systems with pre-mix anti-corrosive additive (iii) Turbocharger.(iv) Fly wheel with fly wheel housing.(v) Electrical engine starter motor (disengagement after start-up) with Batteries.(vi) Battery charging systems.(vii) Industrial/Residential silencer and exhaust pipes having suitable height with supporting structure.(viii) Stainless steel exhaust flexible elbow.(ix) Thermal sealing of exhaust pipe and aluminium cladding for complete exhaust pipe and silencer.(x) Required filters for fuel, lube oil, air etc.(xi) Sets of flexible hoses as required.(xii) Suitable rubber coupling to Alternator with guard.(xiii) Suitable Engine controller for protection of the engine.(xiv) Coolant heater.(xv) Oil drain Pump.(xvi) Heavy duty air cleaner.(xvii) PT fuel system with Electronic Step Timing Control (ESTC) injectors (xviii) Venturi combo Spin On Oil Filter (xix) Electrical starter motor with soft start engagement feature (xx) Plate type lube oil cooler with first fill of lube oil and coolant.
Item No. 20.069 contd… (b) Engine protections: (i) High coolant temperature warning & trip(ii) Low lubricating oil pressure warning & trip (iii) Low coolant level warning & trip(iv) Fail to crank trip (v) Over crank trip (vi) High and Low speed trip (vii) Low or High battery voltage alarms.(viii) Clogged filter warning (ix) Lack of fuel (x) High Canopy Temperature (xi) Set fail to start protection after failure of the set to start after successful three consecutive start attempts. (c)Starting system :The engine starting shall be by means of totally enclosed axial type electric starter suitable for 24 volts DC starting system comprising of starter motor, voltage regulator and arrangement for initail exciation complete 2 x 12 volt batteries or with suitable number of batteries(25 plates, 180AH Sealed Maintenance Free (SMF) Lead-Acid type) as required as per specifications.The battery shall be supplied with a suitable floor mounted MS stand treated with seven tank treatment, two coats of red oxide /primer & acid resistant paint.with wooden base, adaptor box etc . with copper conductor battery leads of required length and socket/clamps (d) Engine mounted Instrumentation Panel fitted with and having digital display for th following : (i) Start stop switch with key (ii) water temperature indication (iii) Lubrication oil pressure indication (iv) Lubrication oil temperature indication (v) Battery charging indication and RPM indication (vi) Over speed indication and Engine hours indication (vii) Low lube oil temp indication.
Item No. 20.069 contd… (e) Alternator : Brushless Type, Screen protected, Revolving field, Self excited Permanent Magnet Generator(PMG) Alternator conforming to IS/IEC 60034-1 rated at 600 kVA 3 phase 0.8 PF 415V, 4 wire 1500 rpm ,Class H insulation, self regulated through AVR confirming to IS :4722/BS 2613 suitable for tropical condition with brush less exciter,dynamicaaly balanced rotor,alternator efficiency not less than 94.6%, housed in screen protected drip proof enclosure . The alternator shall be confirming to IS 13364 Part-2 & IS 15999 Part-1/ IEC 60034 Part-1 capable of delivering rated output at rated power factor with the following :- (i). Terminal voltage differing from the rated value by not more than +/- 5%. (ii). Frequency differing from the rated value by not more than +/-0.5%. (iii). Short circuit capacity of 300% for 10 seconds. (iv). Over load capacity of 110% for one hour.The insulation class of the Alternator shall be class H. The temperature rise shall be limited to class B and Ingresses enclosure protection shall IP23 or better. The alternator shall be fitted with suitable Nos. Resistance Temperature Device (RTD) & Bearing Temperature Device (BTD) along with space heaters. (f) Alternator Protection :Alternator should have following protections (i) Over and Under voltage (ii) Under and Over frequency warning and trip (iii) Loss of excitation (iv) Over current and Earth Fault and Short Circuit Protection (v) Unbalanced loads (vi) Restricted Earth Fault Protection.(vii) Differential protection.(viii) Diode Failure.
Item No. 20.069 contd… (g) Voltage regulator :A rapid response voltage regulator shall be provided to regulate the generated voltage.The overall regulations from no load to full load, including cold to hot variation and load power factor of 0.8 lag to unity shall be within 2% of the normal voltage. The excitation system shall be designed to promote rapid voltage recovery following sudden application and disconnection of load. (h) Acoustic enclousure : The acoustic enclosure should be supplied along with DG set from the manufacturer outlet itself as per CPCB norm.Acoustic enclosure shall be of powder coated and fabricated out of 2mm thick CRCA MS sheet. The canopy shall have four hinged doors, one door with glass window to view proper parameters on the control panel. The canopy and doors shall have inside lining of fire retardant foam/glasswool as acoustic materials. The base frame shall be fabricated in ISMC channel or in sheet metal, with lifting hooks for convenient lifting of complete set i.e. along with canopy, engine and alternator. The sound level shall have less than 75 db (A) at a distance of 1 meter.High quality noise absorbant and fire-retardant grade acoustic Insulation material (P.U. Foam) complying to IS 8183. The allowable temperature raise inside the canopy is 5 to 7 deg. Centigrade. The Measurement of noise should be as per ISO 3744/ ISO 8528 (Part 10) standard.The canopy has the provision of emergency push button, external to the canopy (j) Governor :The governor shall be of electronic type Integral with FIP & Isochronous capability , suitable for monitoring constant engine speed within the specified limits for auto parallel and auto load sharing operation.
Item No. 20.069 contd… (k) Exhaust : The exhaust piping system shall be supplied with a hospital grade silencer and catalytic converter suitably optimized to meet stringent noise emission standards laid down by MoEF / CPCB.The exhaust piping and the silencer shall be wrapped with rock wool and/or calcium silicate. The outside shall be neatly wrapped with aluminum cladding. The exhaust line shall be extended beyond the height of the utility building roof as required by pollution control norms.Suitable supporting structure for installation shalll be provided.The piping shall be confirming to IS:3589 cut to required length and installed with necessary bends, supports and clamps. (l) Hot air exhaust (Radiator cooling): GI duct shall be provided for hot air exhaust from DG set up to designated place of duct outlet. The duct shall be made of 14 Gauge thick Class-8, Galvanized Iron (GI) Sheet.Galvanised Iron (GI) duct shall be provided for venting hot exhaust air out of the DG room, from radiator hot air outlet point of the DG Acoustic enclosure through nearest brick wall. (m) Fuel Tank : Inbuilt/internal bottom mounted (with-in DG set or with-in base frame) diesel tank of suitable capacity with mounting brackets, complete with fuel inlet, out let, air vent, drain plug, level indicator, inter connection pipes from tank to diesel generator as required. Suitable barrier shall be provided between Diesel tank and the Engine. Fuel tank shall be fabricated from 3.0mm thick MS sheet complete with all accessories and fuel piping between fuel tank and diesel engine with MS class C pipe of suitable dia complete all as specified and as per tropical condition of Chakeri,Kanpur.Standard Fuel tank Capacity (832 litre) and designed capacity shall be suitable for 8 hrs continous operation.
Item No. 20.069 contd… (n) Control Panel : Control panel shallbe manufactured with 14/16 gauge CRCA sheet duly powder coated. The control panel consists of the following parts: (a) Intergrated advanced digital Controller control system microprocessor-based suitable for generator set monitoring (b) Metering and control system with LCD display designed to meet the demands of engine driven generator sets (c ) Aluminum bus bars with suitable capacity with incoming/outgoing terminals (d) Instrument fuses duly wired and ferruled (e) Air Circuit Breakers (ACBs)/Moulded Case Circuit Breaker (MCCB) of suitable rating with overload and short circuit protections. (o) Base Frame and Foundation : Both the engine and alternator mounted on suiatble base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendation of manufacturer. Note : (i) DG Set shall be composite type with control panel, Prime mover, alternator and allied accesories in one enclosure (ii) LT Cable of suitable rating from DG set Alternator output to Automatic main failure panel (AMF panel) should be provided by the contractor .(iii) Cost of DG set foundation deemed to be included in cost of item.(iv) Contractor should submit necessary drawing to GE/Engr-in-Charge before procurement.(v) Control panel shall be shall be manufactured and installed by OEM of DG Set.
Supply,installation,connecting,testing and commissioning of micro processor / relay based AMF control panel designed for Automatic ON Mains Failure Operation of the Generator sets. The Panel will be totally enclosed, Dust tight, vermin proof,IP 54 degree of protection,floor mounted, free standing, cubical compartmentalized type with hinged doors, fabricated from 14 SWG CRCA Steel metal having separatecompartments . The Panel will be epoxy painted powder coated with light grey shade, After Seven Tank treatment, and the Panel / compartment will be fitted with the following instrument and pre-wired with colour coded flexible copper cable with ferule Numbers for easy identification & maintenance. The panel shall be complete with interconnections, insulators, two nos. of earthing lugs and with suitable rating of ACB/MCCB at both the end & shall incorporate the followings
FIRE ALARM AND FIRE FIGHTING SYSTEM/FIRE HYDRANT/PANEL PROTECTION
Supply, installation, testing and commissioning of LT panel indoor type floor mounted Motor Control Centre design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections. The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm
Item No. 20.071 contd… .The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for suitable for motors of and pumps complete as required and comprising of the following:- (A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering
Item No. 20.071 contd… (iii) Indication lamps LED type (RYB) =01 set of three .(iv) MCB SP 6A 'C' series for control ckt protection = 02Nos. (B). INCOMER (i) MCCB 250 Amp 4 pole, 36 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with adjutsable magnetic and adjustable thermal release, adjustable overload 65% to100% and adjustable short circuit release from 3.5 to10 ln setting complete with phase seperator - 03 Nos(02 Working + 01 standby) Note :Above 02 breakers are interlocked electrically and mechanically so that only one incomer breaker be put on at one time. (C). OUTGOING for main fire pump , sprinkler pump , jockey for both sprinkler and hydrant Main Pumps (i) MCCB 160 Amp 3 pole, 36 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with adjutsable magnetic and adjustable thermal release, adjustable overload 65% to100% and adjustable short circuit release from 3.5 to10 ln setting complete with phase seperator , with CT operated digital ammeter (0-250 A) , with 3 CT's of 250/5 A ,10 VA , accuracy 1.0 , ASS and coloured LED for on / off (green / red) indicated- 2 sets . (ii) Fully automatic star delta starter suitable for main fire pump and sprinkler pump (minimum 60 HP capacity) complete with over load protection , current sensing type single phase preventer complete with all protection , current sensing type single phase preventer complete with all accessories and wiring etc. as required - 2 sets (iii)Start/Stop/Reset push buttons -02nos(iv) Phase indication/Motor ON/Motor OFF/Trip indicating lamps LED type -02 set (v)Auxillary control relays -02 set (vi) Surge Supressor 415 volts 20 KA -02 nos
Item No. 20.071 contd… (vii) Protections:- Phase failure, unbalance, phase sequence , overloading and dry running(under current) (viii) 3 pole Power contactors suitabel size confirming to IS/IEC 60947-4-1 suitable for 3 phase 415Volts,50Hz AC supply with auxillary contact 2NO + 2 NC for motor operation -02 nos or as per requirement of panel designer (ix) MCB SP 6amp 10 KA -03 nos Pressurisation pump( Jockey Pump) (i) MCCB 40 Amp 3 pole, 25 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator , with CT operated digital ammeter (0 -60 A) with 3 CT's of 60 / 5 A , 10 VA accuracy 1.0, ASS and coloured led for on / off ( green / red) indication with adjustable thermal magnetic release and (ICS = 25 KA upto 433 V) - 02 set (ii) Fully automatic star delta starter suitable for pressurization pump (minimum 10.0 HP capacity ) complete with over load protection current sensing type single phase preventer complete with all accessories and wiring etc . as requred - 02 set . (iii)Start/Stop/Reset push buttons -02nos(iv) Phase indication/Motor ON/Motor OFF/Trip indicating lamps LED type -02 set (v)Auxillary control relays -02 set (vi) Surge Supressor 415 volts 20 KA -02 nos(vii) Protections:- Phase failure, unbalance, phase sequence , overloading and dry running(under current) (viii) 3 pole Power contactors suitabel size confirming to IS/IEC 60947-4-1 suitable for 3 phase 415Volts,50Hz AC supply with auxillary contact 2NO + 2 NC for motor operation -02 nos or as per requirement of panel designer (ix) MCB SP 6amp 10 KA -03 nos
Supply, installation, testing and commissioning of LT panel outdoor type floor mounted Motor Control Centre (Terrace Pump)design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 3.15mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 2.0 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections. The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.
Item No. 20.072 contd… EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 30x30x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for suitable for motors of and pumps complete as required and comprising of the following:- (A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three .(iv) MCB SP 6A 'C' series for control ckt protection = 02Nos.
Item No. 20.072 contd… (B). INCOMER (i) MCCB 40 Amp 4 pole, 25 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator - 01 nos (C). OUTGOING (i) MCCB 32 Amp 3 pole, 25 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator with CT operated digital ammeter (0 -60 A) with 3 CT's of 60 / 5 A , 10 VA accuracy 1.0, ASS and coloured led for on / off ( green / red) indication - 01 set (ii) Fully automatic star delta starter suitable for pressurizationpump (minimum 7.5HP capacity ) complete with over load protection current sensing type single phase preventer complete with all accessories and wiring etc . as requred - 02 set . (iii)Start/Stop/Reset push buttons -01nos(iv) Phase indication/Motor ON/Motor OFF/Trip indicating lamps LED type -02 set (v)Auxillary control relays -01 set (vi) Surge Supressor 415 volts 20 KA -01 nos(vii) Protections:- Phase failure, unbalance, phase sequence , overloading and dry running(under current) (viii) 3 pole Power contactors suitabel size confirming to IS/IEC 60947-4-1 suitable for 3 phase 415Volts,50Hz AC supply with auxillary contact 2NO + 2 NC for motor operation -01 nos or as per requirement of panel designer (ix) MCB SP 6amp 10 KA -02 nos
Supply and lay in trenches ductile iron pipes with double flanged ends with external diameter DE 170mm and nominal dia of size DN 150 mm,nominal pipe wall thickness not less than 6.0mm class K-9 rating, ISI marked Centrifugally Cast (Spun) Ductile Iron Pressure pipes conforming to IS:8329/2000 classification ,suitable for push-on-joint(Rubber gasket-D jointing) with cement mortor lining inside the pipes and outside zinc coating with Bituminous finish coat as per IS:8329/2000 including EPDM rubber joints conforming IS: 5382 of 1985 all as specified and as directed .
Supply and Fixing XLPE insulated and PVC sheathed,armoured galvanised wire,1100 volts grade copper conductor cable Extruded PVC Type ST2 Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988.complete all as required and specified for the sizes of cables 3C X 4 sqmm copper conductor, 2XWY.
Supply and Fixing XLPE insulated and PVC sheathed,armoured galvanised wire,1100 volts grade copper conductor cable Extruded PVC Type ST2 Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988.complete all as required and specified for the sizes of cables 3C X 6.0sqmm copper conductor, 2XWY
Supply and Fixing XLPE insulated and PVC sheathed,armoured galvanised wire,1100 volts grade copper conductor cable Extruded PVC Type ST2 Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988.complete all as required and specified for the sizes of cables 4C X 1.5sqmm copper conductor, 2XWY
Supply and Fixing XLPE insulated and PVC sheathed,armoured galvanised wire,1100 volts grade copper conductor cable Extruded PVC Type ST2 Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988.complete all as required and specified for the sizes of cables 4C X 2.5sqmm copper conductor, 2XWY
Supply and Fixing XLPE insulated and PVC sheathed,armoured galvanised wire,1100 volts grade copper conductor cable Extruded PVC Type ST2 Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988.complete all as required and specified for the sizes of cables 3C X 10.0sqmm copper conductor, 2XWY
Supply and Fixing XLPE insulated and PVC sheathed,armoured galvanised wire,1100 volts grade copper conductor cable Extruded PVC Type ST2 Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988.complete all as required and specified for the sizes of cables 2C X 1.5sqmm copper conductor, 2XWY
Supply and making and termination with brass compression gland and aluminium lugs for XLPE insulated PVC sheathed armoured aluminimum/copper conductor cable of 1.1 KV grade confirming to IS - 7098 Part-1 as required. all as specified and as directed for the size 3C X 4 sqmm copper conductor, 2XWY
Supply and making and termination with brass compression gland and aluminium lugs for XLPE insulated PVC sheathed armoured aluminimum/copper conductor cable of 1.1 KV grade confirming to IS - 7098 Part-1 as required. all as specified and as directed for the size 3C X 6.0sqmm copper conductor, 2XWY
Supply and making and termination with brass compression gland and aluminium lugs for XLPE insulated PVC sheathed armoured aluminimum/copper conductor cable of 1.1 KV grade confirming to IS - 7098 Part-1 as required. all as specified and as directed for the size 4C X 1.5sqmm copper conductor, 2XWY
Supply and making and termination with brass compression gland and aluminium lugs for XLPE insulated PVC sheathed armoured aluminimum/copper conductor cable of 1.1 KV grade confirming to IS - 7098 Part-1 as required. all as specified and as directed for the size 4C X 2.5sqmm copper conductor, 2XWY
Supply and making and termination with brass compression gland and aluminium lugs for XLPE insulated PVC sheathed armoured aluminimum/copper conductor cable of 1.1 KV grade confirming to IS - 7098 Part-1 as required. all as specified and as directed for the size 3C X 10.0sqmm copper conductor, 2XWY
Supply and making and termination with brass compression gland and aluminium lugs for XLPE insulated PVC sheathed armoured aluminimum/copper conductor cable of 1.1 KV grade confirming to IS - 7098 Part-1 as required. all as specified and as directed for the size 3.5C X 95sqmm aluminium conductor
Supply and making and termination with brass compression gland and aluminium lugs for XLPE insulated PVC sheathed armoured aluminimum/copper conductor cable of 1.1 KV grade confirming to IS - 7098 Part-1 as required. all as specified and as directed for the size 3C X 35sqmm aluminium conductor
Supply and making and termination with brass compression gland and aluminium lugs for XLPE insulated PVC sheathed armoured aluminimum/copper conductor cable of 1.1 KV grade confirming to IS - 7098 Part-1 as required. all as specified and as directed for the size 3C X 25sqmm aluminium conductor
BLANK
BLANK
Providing and applying two coat of 4 mm thick 'PYPKOTE' antirust protection including primer and lap of 25 mm on M.S. pipe 150mm dia in trenches or complete including surface preparation coating and wrapping shall be confirm to ISI 10221 including conducting Holiday Test complete all as specified and directed.
Supplying & erecting vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 150 mm dia having following features :- 1)Visual Switch Activation 2) Rugged Switch Assembly 3) Heavy Duty Alluminium pipe Saddles 4) Durable Metal Encloser 5) Steel U Bolts For Secure Mounting 6) Two SPDT (Single Pole Double Track) Synchronised Switches 7) Serviceable Without Draining Pipes
Supplying & erecting vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 100 mm dia having following features :- 1)Visual Switch Activation 2) Rugged Switch Assembly 3) Heavy Duty Alluminium pipe Saddles 4) Durable Metal Encloser 5) Steel U Bolts For Secure Mounting 6) Two SPDT (Single Pole Double Track) Synchronised Switches 7) Serviceable Without Draining Pipes
Supplying & erecting vane type water flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 75/80 mm dia having following features :- 1)Visual Switch Activation 2) Rugged Switch Assembly 3) Heavy Duty Alluminium pipe Saddles 4) Durable Metal Encloser 5) Steel U Bolts For Secure Mounting 6) Two SPDT (Single Pole Double Track) Synchronised Switches 7) Serviceable Without Draining Pipes
Providing and fixing single gunmetal suction collecting head as per IS : 904 - 1983 , hose coupling (draw out connection) with female outlet as per IS : 903 complete with 150 mm dia , G.I suction pipe (with puddle flange) with a foot valve with strainer complete as per drawings .(fire tank)all as specified and as directed.
Supply, Installation, testing and commissioning of air release valve of 25 mm dia and 25 mm dia gun metal gate valve with fittings etc. to be installed at risers. with necessary G.I. coupling to be fitted on top of Air vessel or on wet riser as per specification all as specified and as directed.
Supply and fixing 25 mm dia MS pipe inspecting & testing assembly with gunmetal valve, Bronze sight glass, bypass valve & connected to drain line
Supply and fixing Orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size 160 mm outer dia of 160 mm at every single hydrant valve to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.all as specified and as directed.
Supply, erection, testing and commissioning of fire brigade draw off connection confirming to IS : 4038-1986 with 150 mm Non return valve/ strainer incluiding necessary fittings the word FIRE BRIGADE DRAW OFF to be painted on the box complete all as specified and directed.
Supply, erection, testing and commissioning of THREE WAY fire brigade inlet connection to wet riser system which comprises of 3 No. 63 mm dia Gun metal NRV, 1 No. powder coated weather proof standard hose box suitable for accommodating the above components fabricated out of 16 SWG MS sheet with central opening, glazed front incluiding necessary fittings the word FIRE BRIGADE DRAW OFF to be painted on the box complete all as specified and directed.
Material and labour for construction of valve chamber of size 1200x 1200 x 1000 mm deep dimensions (Over all internal dimension) for sluice valve etc. with PCC foundation, PCC block masonry walls, Plastering, PCC Coping, white washing, mild steel chamber cover, painting to chamber cover including Excavation and earth work in any type of soil complete all as specified below:- Valve chamber shall be provided with the following specifications:-(i) Cement concrete for foundation (1:4:8) type D2 using 40mm graded stone aggregate 150 mm thick extended up to 150 mm beyond the outer face of block masonry.(ii) Walls of valve chamber 200 mm thick with precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building blocks , setting in CM 1:6 complete. (iii) Internal and exposed surfaces of valve chamber both concrete and block masonry surface shall be plastered with CM (1:4), 15 mm thick finished even and smooth.(iv) 50 mm thick coping in PCC 1:3:6 type C1 over block masonry wall.(v) Entire plastered surfaces shall be treated with 3 coat of white wash.(vi) Chamber cover shall be of 6 mm thick MS sheet with 30 x 30 x 5 mm size angle iron frame with hold fast and locking arrangement. steel surface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer complete all a specified and as directed.
FIRE EXTINGUISHERS
Supply & fixing of ISI marked (IS: 15683) portable Co2 fire extinguisher of capacity 4.50 kg flat base including valve discharge hose of not less than 10mm dia. meter complete in all respect including initial fill with Co2 gas confirming to IS 307-1966 and filled to filling ratio of not more than 0.367 complete all as specified and as directed.
Supply & fixing of ISI marked (IS: 15683)4.0 kg Clean Agent Fire Extinguishers complete all as specified and as directed.( For sophisticated medico - electronics/electronics/IT equipment)
Supply & fixing of ISI marked (IS: 15683) portable AFFF foam type fire extinguisher, Capacity 9.0 lit complete all as specified and as directed.
Supply & fixing of ISI marked (IS: 13849/15683) portable ABC multipurpose DCP(mono monioum phosphate powder) , nitrogen pressurised type fire extinguisher, Capacity 6.0 kg complete all as specified and as directed.
Supply & fixing of ISI marked trolley mounted fire extinguisher, 25kg wheeled Dry Powder Extinguishers complete all as specified and as directed.
Supply & fixing of ISI marked (IS: 2878) portable Co2 fire extinguisher of capacity 22.5 kg flat base including valve discharge hose of not less than 10mm dia. meter complete in all respect including initial fill with Co2 gas confirming to IS 307-1966 and filled to filling ratio of not more than 0.367 complete all as specified and as directed.
FIRE STAND/ FIRE POINT
Supply only Round bottom FIRE Bucket of 9 Litres capacity asper IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE complete all as specified and directed.
Supply and fix only Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint.
Supply only of ISI marked (IS: 15683) portable Co2 fire extinguisher of capacity 4.50 kg flat base including valve discharge hose of not less than 10mm dia. meter complete in all respect including initial fill with Co2 gas confirming to IS 307-1966 and filled to filling ratio of not more than 0.367 complete all as specified and as directed.
Supply only of ISI marked (IS: 13849/15683) portable ABC multipurpose DCP(mono monioum phosphate powder) , nitrogen pressurised type fire extinguisher, Capacity 9.0 kg complete all as specified and as directed.
Supply only fire extinguisher water stored pressure type ISI marked (IS: 15683) Capacity 9.0 kg complete all as specified and as directed. Note:(i) Installation of fire stand shall be carried out as per user requirement.(ii) Necessary arrangement for installation incl civil work required at site deemed to be included in the item cost.(iii) Each fire point shall be provided with fire bucket -04 nos,fire stand,Co2 fire extinguisher,ABC type fire extinguisher and water store pressure type extinguisher -01 nos each
PANEL PROTECTION
Supply,Installation,Testing and Commissioning of 4 kg capacity FM 200 Fire extinguisher, DHP Assembly with automatic valve CE & pie approved, push in connector for tube, mounting bracket, End of Line adopter and low pressure switch for monitoring system activation.
BLANK
Supply, installation, testing and commissioning of LT panel indoor type floor mounted Main Panel design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections. The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 .
Item No. 20.114 contd... and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc. The panel shall be designed for suitable for motors of and pumps complete as required and comprising of the following:- (A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three .(iv) MCB SP 6A 'C' series for control ckt protection = 02Nos (B). INCOMER (i) MCCB 400 Amp 4 pole, 36 KA, lcs =100% lcu, microprocessor release ,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) Adjustable Overload, Short-circuit, Ground fault (4 Pole) & Fixed Instantanous Netural Protection (4 Pole), adjustable overload release 70% to100% and adjustable short circuit release from up to 10 ln setting complete with phase seperator- 01nos (C). OUTGOING for main fire pump MCC , Terrace pump and Domestic water supply pump (i) MCCB 250 Amp 4 pole, 36 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with adjutsable magnetic and adjustable thermal release, adjustable overload 65% to100% and adjustable short circuit release from 3.5 to10 ln setting complete with phase seperator- 01
Item No. 20.114 contd... (ii) MCCB 63 Amp 4 pole, 25 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator- 02 nos (iii) MCCB 40 Amp 4 pole, 16 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator- 03 nos Note: (i) LT panel shall be CPRI approved (ii) Contractor shall submit the following Test report i.e. IP Test Report and verification of short circuit withstand test report to GE (iii) Contractor shall submit GA drawing prior to procurement of LT Panel for approval of GE/CWE. (iv) The items mentioned in description are indicative only. Any item not specifically mentioned but required for reliable, safe and unattended trouble free operation shall be included in the scope of the contractor for which no additional payments shall be made.
FIRE DETECTION AND ALARM SYSTEM
Supply,installation ,testing and commissioning of EN-54 certified intelligent addressable Duct detector in AHU Suppy / return air Duct ,having Rotary, decimal addressing system (address switch) with standard base and junction box. The detector shall be with Visible bi-color LEDs for 360 deg viewing and shall blink green every time the detector is addressed, and illuminate steady red on alarm. Detector shall be UL Listed. As per NFPA 76/318 complete as required all as specified and as directed.
Supply, installation, testing & commissioning of the Supervised addressable Dual relay output / control module for tripping of AHU/hooter/strobe shall be certified to EN-54 2A @ 24 VDC Power Limited and must be must be addressed from 1 – 127 prior to installation on the SLC loop. Modules using binary jumper or dip switch setting are not acceptable. The device address shall be electrically programmable and stored in EEPROM. A bi-colored LED shall indicate device status. Operation parameters are maintained by the module, and human interface with the control system during emergency not required complete all as required and as per specifications.
Supply,Installation,Testing & Commissioning of Analogue Addressable Control module having Rotary, decimal addressing system and shall be capable of providing DPDTcontact rated at 24v DC, 2A.complete as required all as specified and as directed.
Supply,Installation,Testing & Commissioning of Analogue Addressable Monitor module having Rotary, decimal addressing system for monitoring the field devices & shall be capable of providing DPDTcontact rated at 24v DC, 2A.complete as required all as specified and as directed.
Supply,Installation,Testing & Commissioning of Analogue Addressable Control relay module having Rotary, decimal addressing system for AHU tripping and shall be capable of providing DPDTcontact rated at 24v DC, 2A. complete as required all as specified and as directed.
Supply,installation ,testing and commissioning of Remote Response indicator with twin transparent LED that shall glow red in case of fire for all detectors located above false ceiling all as specified and as directed.
Supply, Installation,Connecting, Testing & Commissioning of Active Repeater Panel with a 640-character Liquid Crystal Display (LCD) for monitoring the Fire Alarm Systemto be integrated with Fire Alarm Control Panel with piezo sounder,larger display Full colour 800 x 480 LCD dispaly with resistive touch screen and automatic back-light dimming and the status of any Fire/Fault of Integrated Fire Alarm Panels,with accept /reset buttton for alarm address of any sensor/field device the repeater panel shall only provied field device address of any room number .Panel Should Include Battery charger with 2 Nos. 12 Volt Battery Backup upto 6.0 hours.Panel should compliant with EN54-2. This shall provide the event and programmed custom messages as displayed on the main panel .The panel shall be UL listed and FM approved.complete all as required and as specified.
Supply,installation,connecting,testing and commissioning of fire alarm PC station consisting of pentium 4 processor ,17" colour LCD TFT monitor ,1GB RAM,160 GB hard disk , DVD drive ,USB Port ,mouse,window XP based software , graphic software including copy in CD rom complete as required PC work station shall include complete fire alarm graphics software including floor plans with location of detectors and other devices . all floors shall be available as drawing files with location of detectors and devices complete with loop number and other details as available on the software. NOTE:- The software shall be customised to the building and fire alarm layout of the building with location of detectors marked on floor drawings complete with detector address , detector condition etc. the PC and software shall allow for programming / re programming of detector addresses , addition or deletion of detectors with address change , condition of detectors , event logs for 1000 event complete .The software shall be supllied complete with registered CD unit complete and site training .all as specified and as directed.
Supply,installation ,connecting,testing and commissioning of power supply unit with 25 AH SMF battery of 2 x 12 volts for 15 minute back up complete in wall mounted MS cabinet unit . all as specified and as directed.
Supply, laying, testing and commissioning of cabling for fire detection and alarm system 600/1000v with 1.5Sq.mm 2 core steel wire armoured fire alarm system cable annealed tinned multi strand copper conductor PVC Insulated flexible FRLS outer sheath wire in MS conduit as required. Note:-MS conduit shall be measured and paid seperately.
Supply ,installation,testing and commissioning of twin parallel Speaker cables manufactured with multi wire, bright annealed flexible bare electrolytic grade copper conductor FR (Fire Retardant) PVC compound with high value of oxygen and temperature index of size two pair 2 core x 1.50 sq.mm Thickness of Insulation 0.80mm complete all as required and as specified.
Supplying, installing, testing and commissioning of 1 W to5/ 6 W Tapping ceiling mounted type UL listed speakers with multi-tapping capable to produce minimum sound level of 75db at 3m distance.Complete as required all as required and as specified.
Supply and fix control console complete all as required and as specified.
Supply,installation,testing and commissioning of 6 Zone, voice alarm controller with USB, MP3 player , AM/FM player (including six zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required.
Supply,installation,testing and commissioning of intelligent interface unit with modbus protocol for communication links between BMS and fire panel complete all as required and as specified.
Supply, installation, testing and commissioning of Building Management system (BMS) for display and realtime monitoring of certain parameters of E/M services ( Fire alarm control panel integration, chiller integration, lift integration, Diesel generators and Electric supply mains) as per IO summary enclosed as Appx "B" and integration of the same with BMS/MIMIC panel complete all as specified and as directed by Engineer-in-charge. the BMS shall be comprised of following components as under:- (a) BMS Monitoring Hardwares : The Central Server shall be Intel XEON Based CPU, Octa Core, 32 GB RAM, 2 TB HDD , Pre Loaded with Windows Server 2012 - 64 Standard (Licensed), OS, Database, Firewall and AntiVirus including provision fir DVD RW -01 Nos (b) BMS Work station: The BMS work station shall be Intel i7 Processor, 8 GB RAM, 500 GB HDD, Pre Loaded with Windows 10 Professional Operating Sysytem with US English (QWERTY) QuietKey USB Keyboard Black , Firewall and Antivirus, DVD RQ DVD+/-RW Drive and with Additional Graphics Card NVDIA GTX750 with 4 GB Video RAM and Dual Monitor Display Output on HDMI Interface, with USB Optical Mouse,System Power Cord &PC Speakers etc. complete all as specified -01 Nos. (d ) Monitor : The monitor shall be 40" colour, Flat Screen type HD monitor suitable for 100-230 VAC 50 Hz supply.Working for 24x7 duly wall mounted with swivel stand (to be connected to above PC) -01 Nos (e ) Printer : The printer shall be laser colour printer suitable for speed of 600 dpi or better on A4 size paper -01 Nos (f) BMS Software : BMS Main Server Software capable of Control & Monitoring all BMS Data having a Multi-Protocol Compatible Front End which can support Bacnet ONLY Natively. The BMS Software should be Web Enabled and must be Capable of Integrating to all Third Party Applications as mentioned below. All Licenses and Points to be Considered as per IO Summay and as per the requirement of Third Party Application Integration .
Item No. 20.130 contd.. The Graphical Software shall be customized for providing the facility to create / provide reports/MIMICs/Alarm/Trend/History formats, static and animate the Graphics, Navigation between pages, display of logs, changing the time zones complete as per user requirement developed on the core BMS server module -01 Nos( License version) (g) Middleware & Integrators for Soft Points : The integrator shall be Open Protocol Output Integrators compatible for BACNET/MODBUS output meeting Vendor's communication platform to Acquire data and Control Operation of following Equipment / Hardwares complete with enclosure duly internally wired and tested OEM supplied UL Listed (g) Middleware & Integrators for Soft Points : The integrator shall be Open Protocol Output Integrators compatible for BACNET/MODBUS output meeting Vendor's communication platform to Acquire data and Control Operation of following Equipment / Hardwares complete with enclosure duly internally wired and tested OEM supplied UL Listed (i) FAS System -BacNet Over IP ( License costs to be included as per IO Points) -01 set (ii) DG - Modbus RTU over RS 485 - 01 set (iii) Energy Meter - Modbus RTU over RS 485 -01 set (iv) Chiller Integration -Modbus RTU Over RS 485 -01 set (v) Lift Integration -Modbus RTU Over RS 485 -01 set (j) Field Devices duly wired to DDC: supply, installation with all required fixtures, calibration, testing and commissioning of field sensors for the following (i)Out Door Temperature & RH Sensor - 01 Nos (ii)Immersion Type Temperature Sensor - 04 Nos (iii)Duct type Temperature Sensor - 12 Nos (k)Network Switches : 24 Port network Switch and Accessories
Supply, installation , testing and commissioning of PVC sheathed Instrumentation flexible Cable duly armoured Annealed Bare Copper muiltistranded conductor, PVC insulated, Aluminum Mylar screened, with 0.5 Sq.mm ATC drain wire, for the size Armoured 2 Core x 1 sq mm Al-Mylar Screened with drain wire, Cable for control cabling , complete all as specified and as directed.
Supply, installation , testing and commissioning of PVC sheathed Instrumentation flexible Cable duly armoured Annealed Bare Copper muiltistranded conductor, PVC insulated, Aluminum Mylar screened, with 0.5 Sq.mm ATC drain wire, for the size Armoured 4 Core x 1 sq mm Al-Mylar Screened with drain wire, Cable for control cabling, complete all as specified and as directed.
Supply, installation , testing and commissioning of PVC sheathed Instrumentation flexible Cable duly armoured Annealed Bare Copper muiltistranded conductor, PVC insulated, Aluminum Mylar screened, with 0.5 Sq.mm ATC drain wire, for the size Armoured 2Core x 1.5 sq mm FRLS Unscreened Cable, complete all as specified and as directed.
Supply, installation , testing and commissioning of PVC sheathed Instrumentation flexible Cable duly armoured Annealed Bare Copper muiltistranded conductor, PVC insulated, Aluminum Mylar screened, with 0.5 Sq.mm ATC drain wire, for the size Cat 6 Cable , complete all as specified and as directed.
Supply, Installation , Testing and commissioning of prefabricated type cable tray fabricated out of MS perforated hot dip galvanized sheet of minimum 1.6mm thick (galvanisation thickness not less than 50 microns).The perforation not more than 17.5%. The cable tray suspended from the ceiling with MS suspenders at a distance not mote than 2.50m and near every juction/joint etc.The 50mm flange to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers etc. site condition and rate shall include cost of anchor fastners, screw, nuts, bolts and misc. and other fixing hardware painting of support structure etc as required complete all as specified and as directed for 50 mm width x 50 mm depth x 2.0 mm thickness.
BLANK
BLANK
Supply Installation, testing & Commissioning of microprocessor based 15 kVA UPS online pure sine wave, with IGBT based Rectifier and Inverter or 6Pulse Rectifier with 5th Harmonic Filter along with ACTIVE Filter (Vendor to Define Rating of Active Filter with specifications). Operating Temperature 0- 40°C,Operating Relative Humidity 0 - 95 %,Protection Class IP20.Audible noise at 1 meter from surface of unit < 60 Decibal and Control panel with Multi-function LCD status and control console.UPS Should be True Online Double Conversion (VFI as per IEC62040- 3). 3Phase input & 3 Phase output each comprising of the following. (Suitable for parallel operation).Warranty for UPS shall be 36 Month(S). The approved battery capacity shall be 75Ah to 100 Ah. The UPS shall be EN55022/EN55024 standard and IEC 62040-2 complaince with ISO 9001: 2000 and ISO 14001:1996 certification. and Make: Luminous/ Microtek/Schneider Electric(APC)/Eaton and other approved make.
Item No. 20.140 contd... (a) The UPS shall have Full Load Backup of 30 Minutes and Back up at 50% Load for 40-60 Minutes. (b) The UPS Shall have Soft start Facility for Compatibility with Generators.THD(i) shall be less than 5% @ 100% load. (c ) The Input power factor shall be more than 0.98. from 50% to 100% load. (d) The UPS Shall Not allow deep discharge of the battery. There should be a external MCCB available with UV trip coils. The MCCB should disconnect itself in case of UV or emergency conditions. (e ) Over load :Invertor capability to supply 150% load for 30 sec. 150% for 1 minute, 125% for 10 minutes and >150% for 150ms. (f) Communication : Graphical LCD display with backlight, 04 LEDs for notice and alarm,audiable alarm and 02 Mini-slot communication bays. (g) Shall have inbuilt SNMP, Modbus Cards installed for monitoring on BMS. (h) UPS to have inbuilt provision for Static By-pass enabled and DC breaker for online UPS. (j) UPS shall have output power factor minimum 0.90 with active power factor correction facility in all phases. (k) UPS shall have protective earthing/bonding alongwith suitable capacity RCCB for leakage current protection.
Supply Installation, testing & Commissioning of microprocessor based 20 kVA UPS online pure sine wave, with IGBT based Rectifier and Inverter or 6Pulse Rectifier with 5th Harmonic Filter along with ACTIVE Filter (Vendor to Define Rating of Active Filter with specifications). Operating Temperature 0- 40°C,Operating Relative Humidity 0 - 95 %,Protection Class IP20.Audible noise at 1 meter from surface of unit < 60 Decibal and Control panel with Multi-function LCD status and control console.UPS Should be True Online Double Conversion (VFI as per IEC62040- 3). 3Phase input & 3 Phase output each comprising of the following. (Suitable for parallel operation).Warranty for UPS shall be 36 Month(S). The approved battery capacity shall be 75Ah to 100 Ah.The UPS shall be EN55022/EN55024 standard and IEC 62040-2 complaince with ISO 9001: 2000 and ISO 14001:1996 certification Make: Luminous/ Microtek/Schneider Electric(APC) and other approved make. (a) The UPS shall have Full Load Backup of 30 Minutes and Back up at 50% Load for 40-60 Minutes. (b) The UPS Shall have Soft start Facility for Compatibility with Generators.THD(i) shall be less than 5% @ 100% load. (c ) The Input power factor shall be more than 0.98. from 50% to 100% load. (d) The UPS Shall Not allow deep discharge of the battery. There should be a external MCCB available with UV trip coils. The MCCB should disconnect itself in case of UV or emergency conditions.
Item No. 20.142 contd... (e ) Over load :Invertor capability to supply 150% load for 30 sec. 150% for 1 minute, 125% for 10 minutes and >150% for 150ms. (f) Communication : Graphical LCD display with backlight, 04 LEDs for notice and alarm,audiable alarm and 02 Mini-slot communication bays. (g) Shall have inbuilt SNMP, Modbus Cards installed for monitoring on BMS. (h) UPS to have inbuilt provision for Static By-pass enabled and DC breaker for online UPS. (j) UPS shall have output power factor minimum 0.90 with active power factor correction facility in all phases. (k) UPS shall have protective earthing/bonding alongwith suitable capacity RCCB for leakage current protection.
Supply , fixing, testing and commissioning of galvanic protection Isolation transformer for 15KVA online UPS complete all a specified and as directed.The isoaltion transformer shall be same make of UPS.
Supply , fixing, testing and commissioning of galvanic protection Isolation transformer for 20KVA online UPS complete all a specified and as directed.The isoaltion transformer shall be same make of UPS.
Supply, installation, testing and commissioning of LT panel indoor type floor mounted ( Main UPS Panel, Location : Second Floor Electrical Room) cubical type design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections.
Item No. 20.146 contd... The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for suitable for eletric load complete as required and comprising of the following:- (A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.
Item No. 20.146 contd... The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three.(iv) MCB SP 6A 'C' series for control ckt protection = 03Nos (B). INCOMER (i) MCCB 400 Amp 4 pole, 36 KA, lcs =100% lcu, microprocessor release ,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) Adjustable Overload, Short-circuit, Ground fault (4 Pole) & Fixed Instantanous Netural Protection (4 Pole), adjustable overload release 70% to100% and adjustable short circuit release from up to 10 ln setting complete with phase seperator - 02 Nos(1W + 1 standby) (C). OUTGOING For 08 Major OTs UPS Panel : (i) MCCB 32 Amp 4 pole, 16 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator - 09 Nos(08 nos working + 01 nos Stand by) For General UPS load Panel : (ii) MCCB 40 Amp 4 pole, 16 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator -03 nos( 02 nos working + 01 nos stand by) For Emergency Lighting :(iii) MCB TPN C series 32 Amp,10KA - 04 Nos (iv) MCB SPN C series 16Amp ,10KA -03 Nos (v) MCB SP 5 to 32 Amp,10KA , C series -03 nos
Supply, installation, testing and commissioning of LT panel indoor type floor mounted ( General lighting UPS Panel, Location : Ground Floor and First Floor ) cubical type design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 75mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections. The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm.
Item No. 20.147 contd... The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 35x35x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for suitable for eletric load complete as required and comprising of the following:- (A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three.(iv) MCB SP 6A 'C' series for control ckt protection = 03Nos
Item No. 20.147 contd... (B). INCOMER (i) MCCB 32 Amp 4 pole, 16 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator- 01 nos + 01 nos(Stand by) (C). OUTGOING (i) MCB SPN B series 16Amp/32Amp ,10KA -03 Nos (ii) MCB TPN C series 32 Amp,10KA - 06 Nos (iii) MCB TPN C series 40 Amp,10KA - 02 Nos (iv) MCB SP 5 to 32 Amp,10KA , C series -04nos Note for Item No.20.137 and 20.138: (i) LT panel shall be CPRI approved (ii) Contractor shall submit the following Test report i.e. IP Test Report and verification of short circuit withstand test report to GE (iii) Contractor shall submit GA drawing prior to procurement of LT Panel for approval of GE/CWE. (iv) The items mentioned in description are indicative only. Any item not specifically mentioned but required for reliable, safe and unattended trouble free operation shall be included in the scope of the contractor for which no additional payments shall be made
Supply,installation,testing and commissioning with brass compression gland for XLPE insulated PVC sheathed armoured steel strip copper conductor cable, Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto date Amendments. e as required. all as specified and as directed for the sizes 4C X 10.0 sqmm copper conductor, 2XWY.
Supply,installation,testing and commissioning with brass compression gland for XLPE insulated PVC sheathed armoured steel strip copper conductor cable, Extruded PVC Type ST2 Outer Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto date Amendments. e as required. all as specified and as directed for the sizes4C X 16.0 sqmm copper conductor, 2XWY
Supply, installation, testing and commissioning of LT panel indoor type floor mounted ( Major OTs 1 to 8 UPS Panel, Location : Second Floor ) cubical type design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 75mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections. The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 35x35x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for suitable for eletric load complete as required and comprising of the following:-
Item No. 20.150 contd.. (A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three.(iv) MCB SP 6A 'C' series for control ckt protection = 03Nos (B). INCOMER (i) MCCB 25 Amp 4 pole, 16 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator - 01 nos + 01 nos(Stand by) - 2 nos (C). OUTGOING (i) MCB SPN C series 16Amp/32Amp ,10KA -04 Nos (ii) MCB TPN C series 32 Amp,10KA - 03 Nos (iii) MCB TP C series 40 Amp,10KA - 02 Nos (iv) MCB TP C series 63 Amp,10KA - 02 Nos (v) MCB SP 5 to 32 Amp,10KA , C series -03 nos
Supply, installation, testing and commissioning of Emergency Lighting Control Panel (Approved as per BS EN 60598-2-2 by LIA laboratories ltd) with two lighting lines with maximum of 254 devices on both lines, up to 127 devices per line, luminare line length 500/1000 Metres. The System shall work on Extra Low Voltage as per panel requirement.
Supply, installation, testing and commissioning of ELS Panel Transformer 230 V with an output of 35V AC and is placed between mains and EL2 Control panel. (Approved as per BS EN 60598-2-2 by LIA laboratories ltd) ,
BLANK
Supply, installation, testing and commissioning of Exit Signage visible from 20 mtrs (Approved as per BS EN 60598-2-2 by LIA laboratories ltd) with integral battery capacity of 3 hrs and bicoloured LED status indicator. Available in Left, Right, Down signs with Batteries incorporated into each luminaire shall be Polymer Lithium Ion technology and incorporate over voltage, over current and deep discharge protection circuitry. Battery should provide at least 3 hours luminaire operation when fully charged. (Approved as per BS EN 60598-2-2 by LIA laboratories ltd),
Supply, installation, testing and commissioning of Closed/Open Area LED Down lighter (Approved as per BS EN 60598-2-2 with BS EN 60598-1:2008 +A11 by LIA laboratories ltd) with integral battery capacity of 3 hrs and bicoloured LED status indicator.
Supply & testing of screened and twisted single pair with 1.5Sq.mm 2 core annealed tinned multi strand copper conductor PVC Insulated flexible FRLS wire in MS conduit as required. Note:-MS conduit shall be measured and paid seperately.
AIR CONDITIONING
Supply, installation, testing and commissioning of package type vertical Electric Hot Water Generator capacity 225 kW microprocessor based step controller fabricated out of MS sheet of 10 mm thickness in robust welded construction(as per specifications) having top open-able cover for easy access and removal of heaters. Shell shall be complete with necessary lifting lugs, and provisions for inlet and outlet connections, drain connections, and heating elements. Electric heating elements shall be replaceable, immersion type having solid copper facing designed for low heat concentration, not exceeding 70 W/ 1000 sq.mm.The HWG shall be suitable for indoor mounting with degree of protection IP-55. The generator shall be provided with minimum 50 mm thick resin bonded fibre glass wool insulation 24kg /cm density finished with 0.63mm /24G aluminum cladding sheet. The generator shall have electrical capacity of 225 kW for Water In/Out Temp-40 deg C/50 deg C.Heater bank provided in 3 steps equally for balanced loading, and shall be brought out in the terminal box for switching in stages as required. The heater shall be electrical resistance type, copper tube with chromium plating with scaling resistance coating . The generator shall be complete with float valve, pressure gauge with ball valve, master and bank thermostats, water flow switch etc.
Item No. 20.157 contd... The generator shall be suitable for 3 phase, 415+ 10% Volts, 50 Hz. AC supply.High Standard internal wiring and Electrical Control Panel from an Integral part of Generator's for safe and automatic control of Hot Water Temperature on continued basis.The HWG shall be as per ASME standard and NEMA standard control panel.HWG shall be provided with following facilities as under:- Hot Water Inlet Temperature : 40°C Hot Water Outlet Temperature : 50°C Hot water flow rate- 85 GPM Working Pressure- 230 Psi and Test pressure-300 Psi. Controls : Digital step controller / thermostat for individual step Digital / dial type thermometer for inlet, outlet pipe ( if using thermostats for control ) Pressure gauge with ball valve for inlet, outlet pipe SCR based linear controller ( step less ) for hot water generators Safety Features : Audio / Visual Alarm For Low Water Level Audio / Visual Alarm For High Temperature. Pressure Relief Valve. Door Switch, auto vent valve, high temperature interlock and pump interlock. Safety Thermostat ( Fixed Setting )
Design,Supply, installation, testing and commissioning of close coupled , single stage , centrifugal , end suction with backpull out design chilled water centrifugal pump sets (primary) with bronze impeller complete with TEFC Sq. Cage induction motor IP 55 S1 duty TEFC induction motor with class F insulation, base plate, coupling guard, vibration isolators, SS Shaft, factory fitted mechanical seal, flexible pipe connector at inlet and outlet etc. conforming to technical specification & as per following parameters. The pumps shall be centrifugal type direct driven with a 3 phase, 415 ±10%volts, 50 Hz., A.C. motor. The motor for Chilled Water Pumps shall be suitable for use with Variable Frequency Drive.The efficiency class of motors shall be IE 3 class as per IS 12615.The chilled water pumps shall be duly insulated with Expanded polystyrene (TF quality) 50mm thickness shall be sandwiched between two aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections The cost of thermal insulation deemed to be included in item cost. The pumps are constant speed pump suitable for the given duty points each of 100 % capacity.Pump shall have M.S. fabricated factory fitted base frame duly painted(Out of Three pumps, two will be working and one will be stand by) (Primary water Pump) with the following specification as under.
Design,Supply, installation, testing and commissioning of single-stage, close-coupled, in-line suction Variable flow Pumps with Pump mounted VFD and discharge ports of identical diameter with top-pull-out design with dedicated microprocessor based pump controller close coupled , chilled water centrifugal pump sets( secondary) with bronze impeller for chilled water recirculation complete with Sq. Cage induction motor IP 55 S1 duty TEFC induction motor with class F insulation,, base plate, coupling guard, vibration isolators, SS Shaft, factory fitted mechanical seal, flexible pipe connector at inlet and outlet etc. conforming to technical specification & as per following parameters. The pumps shall be centrifugal type direct driven with a 3 phase, 415 ±10%volts, 50 Hz., A.C. motor. The pump shall be suitable to run on variable frequency drives as required and multiple differential pressure sensor / transmitters as necessary and as described in the specification.sThe motor for Chilled Water Pumps shall be suitable for use with Variable Frequency Drive.The efficiency class of motors shall be IE 3 class as per IS 12615. The Pumps to be capable of providing 10% higher flow rate. All rotating parts are to be covered with an encasing.The chilled water pumps shall be duly insulated with Expanded polystyrene (TF quality) 50mm thickness shall be sandwiched between two aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections The cost of thermal insulation deemed to be included in item cost. The pump shall be suitable for the given duty points each of 100 % capacity.Pump shall have M.S. fabricated factory fitted base frame duly painted(Out of three pumps, two will be working and one will be stand by) (Secondary water Pump) with following specification as under.
Design,Supply, installation, testing and commissioning of close coupled , single stage , centrifugal , end suction with backpull out design condenser water centrifugal pump sets with bronze impeller complete with TEFC Sq. Cage induction motor IP 55 S1 duty with class F insulation, , base plate, coupling guard, vibration isolators, SS Shaft, factory fitted mechanical seal, flexible pipe connector at inlet and outlet etc. conforming to technical specification & as per following parameters. The pumps shall be centrifugal type direct driven with a 3 phase, 415 ±10%volts, 50 Hz., A.C. motor. The motor shall be suitable for use with Variable Frequency Drive.The efficiency class of motors shall be IE 3 class as per IS 12615.The pumps shall be duly insulated with Expanded polystyrene (TF quality) 50mm thickness shall be sandwiched between two aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections The cost of thermal insulation deemed to be included in item cost. The pumps are constant speed suitable for the given duty points each of 100 % capacity.Pump shall have M.S. fabricated factory fitted base frame duly painted(Out of Three pumps, two will be working and one will be stand by) with following specification as under.
Design,Supply, installation, testing and commissioning of close coupled , single stage , centrifugal , end suction with backpull out design hot water centrifugal pump sets with bronze impeller suitable to run on variable frequency drives as required and multiple differential pressure sensor / transmitters as necessary and as described in the specifications with TEFC squirrel cage induction motor IP 55 S1 duty with class F insulation, base plate, coupling guard, vibration isolators, SS Shaft, factory fitted mechanical seal, flexible pipe connector at inlet and outlet etc. conforming to technical specification & as per following parameters.The Pumps to be capable of providing 10% higher flow rate. All rotating parts are to be covered with an encasing. The pumps shall be centrifugal type direct driven with a 3 phase, 415 ± 10%volts, 50 Hz., A.C. motor. The motor shall be suitable for use with Variable Frequency Drive.The efficiency class of motors shall be IE 3 class as per IS 12615.The pumps shall be duly insulated with Expanded polystyrene (TF quality) 50mm thickness shall be sandwiched between two aluminium sheets of 0.5mm thickness and properly clamped to pump in two semicircular sections The cost of thermal insulation deemed to be included in item cost. The pump shall be suitable for the given duty points each of 100 % capacity.Pump shall have M.S. fabricated factory fitted base frame duly painted(Out of two pumps, one will be working and one will be stand by) with following specification as under.
Supply, installation, testing, balancing and commissioning of CLOSED PRESSURISED CHILLED WATER EXPANSION TANK SYSTEM complete with necessary accessories and following provision of items as under:- (a) CLOSED PRESSURISED CHILLED WATER EXPANSION TANK 300 Ltrs capacity ( minimum 650mm dia) ( Chilled water) PN 10 of carbon steel construction with interchangeable synthetic rubber membrane. The expansion tank shall be complete with safety relief valve and pressure gauge along with necessary accessories such as air vents, Pressurisation pumps unit and its panel , with required Support & Foundation etc. The tank will be of pressure rating to suit the system pressure and will be sized to adequately compensate for water expansion due to operating temperature variations. The tank shall be fabricated as per IS 2825-1969 for “non-fired pressure vessels” and the flanges shall be as per IS 6392-1971. The tank shall be precharged M.S expansion tank with replaceable heavy duty butyl rubber bladde in order to keep chilled water system under pressure and to prevent entrapment of air in the system. The tank shall have 20 mm drain and charging valve connection to facilitate the onsite charging of the tank to meet system requirement. For chilled/hot water application,the tank shall be Surface shall be thoroughly cleaned,two coats of hot bitumen shall be applied, insulation slabs of expanded polystrene (TF quality) with 50mm thick fixed in one layer ,insualtion slab then covered with 0.63 mm x 19mm G.I.wire mesh netting and finally be finished with aluminium cladding of thickness not less than 0.5mm. The expansion tank shall be supplied along with pressurization unit. Installation of Expansion tank shall be carried out in accordance with manufacturer’s written instructions.
Item No. 20.162 contd... (c ) The pressurization unit shall consist of two nos. (1 working + 1 stand-by) high pressure pumps of suitable pressure rating mounted on M.S. frame, complete with interconnecting piping, isolation valves, NRV, Y-strainer,pressure gauge, pressure transmitter, auto-logic panel (IP 55) with dry-run protection, electrical MCB and interconnecting wiring. The unit shall be housed in powder-painted canopy suitable for external installation conforming to the specifications. The Pump Shall be BMS Compatible.Microprocessor based control panel with dry run protection and duty cycling.Unit shall be provided with Flow meter to measure the make up water quantity. (d) All Components i.e. pumps, pressure transmitter, flow meter, interconnecting piping and control panel shall be factory mounted on a compact steel frame. Note: (i) Cost of control panel/starter panel for operation of pumps(pressurization unit ) deemed to be included in the cost of item (ii) Cost of interconnecting wiring, cables for pumps for control panel and interconnecting piping deemed to be included in the cost of item
Supply, installation, testing, balancing and commissioning of CLOSED PRESSURISED HOT WATER EXPANSION TANK SYSTEM complete with necessary accessories and following provision of items as under:- (a) CLOSED PRESSURISED HOT WATER EXPANSION TANK 100 Ltrs capacity ( minimum 460mm dia) ( Hot water) PN 10 of carbon steel construction with interchangeable synthetic rubber membrane. The expansion tank shall be complete with safety relief valve and pressure gauge along with necessary accessories such as air vents, Pressurisation pumps unit and its panel , with required Support & Foundation etc. The tank will be of pressure rating to suit the system pressure and will be sized to adequately compensate for water expansion due to operating temperature variations. The tank shall be fabricated as per IS 2825-1969 for “non-fired pressure vessels” and the flanges shall be as per IS 6392-1971. The tank shall be precharged M.S expansion tank with replaceable heavy duty butyl rubber bladde in order to keep chilled water system under pressure and to prevent entrapment of air in the system. The tank shall have 20 mm drain and charging valve connection to facilitate the onsite charging of the tank to meet system requirement. For chilled/hot water application,the tank shall be Surface shall be thoroughly cleaned,two coats of hot bitumen shall be applied, insulation slabs of expanded polystrene (TF quality) with 50mm thick fixed in one layer ,insualtion slab then covered with 0.63 mm x 19mm G.I.wire mesh netting and finally be finished with aluminium cladding of thickness not less than 0.5mm. The expansion tank shall be supplied along with pressurization unit. Installation of Expansion tank shall be carried out in accordance with manufacturer’s written instructions.
Item No. 20.163 contd... (c ) The pressurization unit shall consist of two nos. (1 working + 1 stand-by) high pressure pumps of suitable pressure rating mounted on M.S. frame, complete with interconnecting piping, isolation valves, NRV, Y-strainer,pressure gauge, pressure transmitter, auto-logic panel (IP 55) with dry-run protection, electrical MCB and interconnecting wiring. The unit shall be housed in powder-painted canopy suitable for external installation conforming to the specifications. The Pump Shall be BMS Compatible.Microprocessor based control panel with dry run protection and duty cycling.Unit shall be provided with Flow meter to measure the make up water quantity. (d) All Components i.e. pumps, pressure transmitter, flow meter, interconnecting piping and control panel shall be factory mounted on a compact steel frame. Note for item 20.155 & 20.156 :(a)The expansion tank shall be connected to suction side of pump with all fittings including necessary piping duly insulated but with out any valve.(b) The department will show make up connection(within 5 Mtr of Expansion Tank.) (c) Connection of Expansion tank with make up water connection is contractor's responsibility.
Supply, fixing, testing and commissioning in position the butterfly valve 32/40 mm (50 mm insulation) in chilled water and hot water pipeline complete with flanges etc, confirming to API 609,BS 5155 shall be wafer type for mounting between specified flanges and shall be rated for PN 1.6 (16 bar) Pressure rating. bodies shall be cast ferrous metal conforming to ASTM A126 CL B/ IS 210 Gr FG 200 for body wall thickness and disc shall be Stainless steel, with replaceable nitrile linner seats and seals shall be of the resilient elastometric type designed for field removal complete with accessories such as matching flanges,gasket , hardware etc for chilled water and hot water circulation duly insulated with fire retardant quality expanded polystrene (TF quality)( density 20 Kg per cum and thermal conductivity 0.035 K.cal/ hr. degree C/m at 10 Deg C mean temp.) moulded pipe section having thickness not less than 50mm dia up to 125mm dia pipe and 75mm thick for 150mm dia pipe and above, after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500gauge polythene faced (plastic coated)hessian cloth sheet (vapour barrier seal of 120 gm/sq.m polythene sheet with 50mm overlap) (Fire retardent grade),(the polythene facing outwards) and finally secured with 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing bitumen feltstrip(as per IS:1322 as amended up to date ) . the valves and other items shall be adequately supported as per specification complete all as specified and as directed.
Supply, fixing, testing and commissioning in position the Dual Plate check valve( Non return valve) 125 mm (50 mm insulation) in chilled water and hot water pipeline complete with flanges etc,with dual plate of CI body confirming to to ASTM A 126/ IS 210 Gr FG 200 or equivalnet strength ductile iron ,Stainless steel plates,vulcanised NBR seal flanged ends and PN 1.6(16 bar) Pressure rating for chilled water and hot water circulation with insulation as specified .Non return valves shall be of gun metal/bronze construction and duly insulated with fire retardant quality expanded polystrene (TF quality)( density 20 Kg per cum and thermal conductivity 0.035 K.cal/ hr. degree C/m at 10 Deg C mean temp.) moulded pipe section having thickness not less than 50mm dia up to 125mm dia pipe and 75mm thick for 150mm dia pipe and above, after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500gauge polythene faced (plastic coated)hessian cloth sheet (vapour barrier seal of 120 gm/sq.m polythene sheet with 50mm overlap) (Fire retardent grade),(the polythene facing outwards) and finally secured with 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing bitumen feltstrip(as per IS:1322 as amended up to date ) . the valves and other items shall be adequately supported as per specification complete all as specified and as directed.
Supply, fixing, testing and commissioning in position the Y - STRAINER 125 mm (50 mm insulation) in chilled water and hot water pipeline complete with flanges etc, ductile CI body material shall be gun metal confirming to BS:1400 LG2 with flanged ends having filter element stainless steel with permanent magnetic characteristic stainless steel strainer.The strainer element material shall be AISI type 304 corrosion reisitant steel,working pressure rating PN 1.6(16 bar). All stariners larger than DN 65 shall be fitted with manufacturer standard ball type blow down valve for chilled / hot water circulation including insulation as specified and duly insulated with fire retardant quality expanded polystrene (TF quality)( density 20 Kg per cum and thermal conductivity 0.035 K.cal/ hr. degree C/m at 10 Deg C mean temp.) moulded pipe section having thickness not less than 50mm dia up to 125mm dia pipe and 75mm thick for 150mm dia pipe and above, after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500gauge polythene faced (plastic coated)hessian cloth sheet (vapour barrier seal of 120 gm/sq.m polythene sheet with 50mm overlap) (Fire retardent grade),(the polythene facing outwards) and finally secured with 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing bitumen feltstrip(as per IS:1322 as amended up to date ) . the valves and other items shall be adequately supported as per specification complete all as specified and as directed.
Description all as per item no 20.166 Above but size 80 mm (50 mm thick insulation)
Description all as per item no 20.166 Above but 65 mm (50 mm thick i insulation)
Description all as per item no 20.166 Above but size 50 mm (50 mm thick insulation)
Description all as per item no 20.166 Above but size 32 mm (50 mm thick insulation)
Supply, fixing, testing and commissioning in position the Automatic Balancing Valve 65 mm (50 mm thick insulation) Wafer type with built in measuring facility to limit the flow through 3 way valve, GPM for the valve should be factory set to automatically limit the rate of flow with in +/- 5% of specified GPM over 95% of control range. The automatic balance valve with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation including insulation as specified.The valve shall have 2 Pressure ports to read Pressure difference across the valve.The valve shall operate by means of automatic balancing stainless steel catridges with replaceable orifice plate and internal EPDM diaphragms. The pressure class of valve is PN 1.6(16 bar), The valve shall be complete as per specifications and as required. The pressure head loss added to the pump head shall not exceed 7 Ft. A pressure and temperature Kit shall be provided with the ability to read differential pressure from 0-75 PSI and temperature from 0 to 20 deg centigrade. The valve shall be suitable for flange connection and duly insulated with fire retardant quality expanded polystrene (TF quality)( density 20 Kg per cum and thermal conductivity 0.035 K.cal/ hr. degree C/m at 10 Deg C mean temp.) moulded pipe section having thickness not less than 50mm dia up to 125mm dia pipe and 75mm thick for 150mm dia pipe and above, after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500gauge polythene faced (plastic coated)hessian cloth sheet (vapour barrier seal of 120 gm/sq.m polythene sheet with 50mm overlap) (Fire retardent grade),(the polythene facing outwards) and finally secured with 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing bitumen feltstrip(as per IS:1322 as amended up to date ) . the valves and other items shall be adequately supported as per specification complete all as specified and as directed. Note: Slight variation in specifications from one make to another is acceptable.
Description all as per item no 20.171 Above but size 80 mm (50 mm insulation)
Description all as per item no 20.171 Above but size 100 mm (50 mm insulation)
Description all as per item no 20.171 Above but size 125 mm (50 mm insulation)
Supply, fixing, testing and commissioning in position the Motorized 3 Way modulating proportional linear type mixing valve 32 mm (50 mm thick insulation) Motorised Actuator,metal seated,Flanged Ends with Flow switch, Thermostate & Controller For AHUs and chiller header having manual over ride facility with proportional thermostat and wiring with 1.5 sq mm copper conductor multi core armoured cable, 3 way valve suitable for following sizes including actuator of suitable size complete with transformer etc. The valve shall be suitable for flange connection and duly insulated with fire retardant quality expanded polystrene (TF quality)( density 20 Kg per cum and thermal conductivity 0.035 K.cal/ hr. degree C/m at 10 Deg C mean temp.) moulded pipe section having thickness not less than 50mm dia up to 125mm dia pipe and 75mm thick for 150mm dia pipe and above, after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500gauge polythene faced (plastic coated)hessian cloth sheet (vapour barrier seal of 120 gm/sq.m polythene sheet with 50mm overlap) (Fire retardent grade),(the polythene facing outwards) and finally secured with 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing bitumen feltstrip(as per IS:1322 as amended up to date ) . the valves and other items shall be adequately supported as per specification complete all as specified and as directed. Note: Slight variation in specifications from one make to another is acceptable. Note: Proportional thermostat is included in AHU. The rate quoted by the contractor is for 3 way valve and actuator.
Description all as per item no. 20.175 Above but size 50 mm (50 mm insulation)
Description all as per item no. 20.175 Above but size 65 mm (50 mm insulation)
Description all as per item no. 20.175 Above but size 80 mm (50 mm insulation)
Description all as per item no. 20.175 Above but size 100 mm (50 mm insulation)
Description all as per item no. 20.175 Above but size 150 mm (75 mm insulation)
Supply, fixing, testing and commissioning in position the Temperature Gauges shall be Stem type thermometer , case and bezel material of construction shall be aluminium 304, weather proof as per IP 65.Immersion length around 200 mm, connection with SS 304 thermowells protection duly filled with glycerin/equivalent. and duly insulated with fire retardant quality expanded polystrene (TF quality) complete all as specified and as directed.
Supply, fixing, testing and commissioning in position the Pressure Gauge plug complete with fittings , isolation valve etc. complete as reqd.(with out pressure gauge) duly insulated with fire retardant quality expanded polystrene (TF quality) complete all as specified and as directed.
Supply, fixing, testing and commissioning in position the Expansion Bellows 32 mm (50 mm thick insulation) of PN-16 pressure rating made from EPDM or butyl material having wide arch construction, integral gusset plates. Multiple tie rods complete for chilled / hot water across pump and chiller, AHU for resisting the unit vibration to the main pipe Line and duly insulated with fire retardant quality expanded polystrene (TF quality)( density 20 Kg per cum and thermal conductivity 0.035 K.cal/ hr. degree C/m at 10 Deg C mean temp.) moulded pipe section having thickness not less than 50mm dia after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500gauge polythene faced (plastic coated)hessian cloth sheet (vapour barrier seal of 120 gm/sq.m polythene sheet with 50mm overlap) (Fire retardent grade),(the polythene facing outwards) and finally secured with 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing bitumen feltstrip(as per IS:1322 as amended up to date ) complete all as specified and as directed.
Description all as per item no. 20.183 Above but size 50 mm (50 mm insulation)
Description all as per item no. 20.183 Above but size 65 mm (50 mm insulation)
Description all as per item no. 20.183 Above but size 80 mm (50 mm insulation)
Description all as per item no. 20.183 Above but size 125 mm (50 mm insulation)
Description all as per item no. 20.183 Above but size 150 mm (75 mm insulation)
Supply, fixing, testing and commissioning in position the automatic air vent Purging valve of size 25mm for pipes up to 100mm dia pipe and 40mm for larger pipes dia suitable for operating pressure at 3.5 to 4 bar complete with fittings viz nipple,elbow,tee, bend,socket etc with ball valve duly insulated with fire retardant quality expanded polystrene (TF quality) complete all as specified and as directed.
Supply, fixing, testing and commissioning in position the Screwed plug for 150 mm chilled water pipe duly insulated as per pipe specification complete all as specified and as directed.
Description all as per item no. 20.191 Above but size 50mm (50mm insulation) water flow rate 31-60 USGPM
Description all as per item no. 20.191 Above but size 65mm (50mm insulation) water flow rate 60-85 USGPM
Description all as per item no. 20.191 Above but size 80mm (50mm insulation) water flow rate 85-200 USGPM
Description all as per item no. 20.191 Above but size 100mm (50mm insulation) water flow rate 200-400 USGPM
Description all as per item no. 20.191 Above but size 125mm (50mm insulation) water flow rate 400-600 USGPM
Supply, fixing, testing and commissioning in position the Motorized 2 Way modulating proportional linear type mixing valve 32 mm (50 mm thick insulation) Motorised Actuator,metal seated,Flanged Ends with Flow switch, Thermostate & Controller For AHUs and chiller header having manual over ride facility with proportional thermostat and wiring with 1.5 sq mm copper conductor multi core armoured cable, including actuator of suitable size complete with transformer etc.Valve shall be duly insulated with fire retardant quality expanded polystrene (TF quality)( density 20 Kg per cum and thermal conductivity 0.035 K.cal/ hr. degree C/m at 10 Deg C mean temp.) moulded pipe section having thickness not less than 50mm dia after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500gauge polythene faced (plastic coated)hessian cloth sheet (vapour barrier seal of 120 gm/sq.m polythene sheet with 50mm overlap) (Fire retardent grade),(the polythene facing outwards) and finally secured with 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing bitumen feltstrip(as per IS:1322 as amended up to date ) complete all as specified and as directed. ( for FCU/Hi wall split Unit)
Description all as per item no. 20.197 Above but size 20mm (50mm insulation) Note :(i) All valves, fittings, strainers etc. shall be insulated to the same thickness and in the same manner as for the respective piping, taking care to allow operation of valves without damaging the insulation (ii) Plumbing drawings showing the sizes of valves,layout and other details shall be prepared and submit to GE for approval before the execution of plumbing work.
Supply, laying, fixing, testing and commissioning of mild steel condenser water piping of class 'C', Heavy duty minimum thickness as below confirming to IS: 1239 (Part-1) 1991 & IS: 3589-1991Grade 330 (but excluding valves, strainers and pressure gauges etc) laid above ground level with all necessary fabricated fittings such as bends, tees, reducers, flanges, supports, air purge valves, drain valves etc, with necessary fittings,clamps and vibration isolators and fitting adequately supported on rigid supports.Pipes shall rest on half round rigid block resting on GI structure including excavations and refilling the trenches and providing suitable thickness 1:2:4 cement concrete pads at 3 M intervals complete all as specified and as directed by Engr-in-charge for the sizes 200 mm pipe MS class C with 2.0 mm thick double layer FRP coating ( Pipe Minimum wall thickness 6.3mm and minimum outer dia 219.10mm ) ( Cooling Tower purpose)
Description all as per item no. 20.199 Above but size 150 mm pipe MS class C with 2.0 mm thick double layer FRP coating( Pipe Minimum wall thickness 5.4mm and minimum outer dia 163.59mm )
Supply, laying, fixing, testing and commissioning of mild steel condenser water piping of class 'C', Heavy duty minimum thickness as under confirming to IS: 1239 (Part-1) 1991 & IS: 3589-1991Grade 330 (but excluding valves, strainers and pressure gauges etc) .The piping shall be laid outside the plant room buried in ground/trenches as per site conditions or all along the wall/roof with all necessary fabricated fittings such as bends, tees, reducers, flanges, supports, air purge valves, drain valves etc, including necessary fittings,clamps and vibration isolators and fitting adequately supported on rigid supports.The pipes shall be given two coats of tarfelt each having thickness of 2 mm and stick with hot bitumen. Pipes shall rest on half round rigid block resting on GI structure including excavations and refilling the trenches and providing suitable thickness 1:2:4 cement concrete pads at 3 M intervals complete as per specifications and as required all as specified and as directed by Engr-in-charge for the size 200 mm pipe MS class C without FRP coating ( Pipe Minimum wall thickness 6.3mm and minimum outer dia 219.10mm )
Supply, laying, fixing, testing and commissioning of mild steel condenser water piping of class 'C', Heavy duty minimum thickness as under confirming to IS: 1239 (Part-1) 1991 & IS: 3589-1991Grade 330 (but excluding valves, strainers and pressure gauges etc) .Condenser pipes to be laid with in the plant, pipes resting on half round wooden blocks, resting on GI structures with all necessary fabricated fittings such as bends, tees, reducers, flanges, supports, air purge valves, drain valves etc, including necessary fittings,clamps and vibration isolators and fitting adequately supported on rigid supports. All pipes, pipe supports,structures shall be painted with 2 coats of synthetic enamel paint over a coat of red oxide primer and lettering with white paint including marking direction of flow.complete as per specifications and as required all as specified and as directed by Engr-in-charge for the the size 200 mm pipe MS class C without FRP coating ( Pipe Minimum wall thickness 6.3mm and minimum outer dia 219.10mm )
Supply, fixing, testing and commissioning in position the 200mm dia Automatic Balancing Valve electronic type, pressure independent type dynamic balancing valve with integrated 2 way modulating control valve in a single body. The actuator shall be capable of accepting upto 10V DC and upto 20mA electric signal and shall provide similar transduced feedback output to control system. Maximum close off pressure shall not be less than 6 Bar for upto 50 mm valves and 7 Bar for 65 mm & above. Valves should have pressure rating of 25 Bar minimumto ,GPM for the valve factory set to automatically limit the rate of flow with in +/- 5% of specified GPM over 95% of control range. The automatic balance valve with C I body flanged construction with EPDM coated disc with long pitch with protected out pipe insulation & PN 16 pressure rating for chilled /hot water circulation including insulation as specified.The valve shall operate by means of automatic balancing stainless steel catridges with replaceable orifice plate and internal EPDM diaphragms. The valve shall be complete as per specifications and as required. The pressure head loss added to the pump head shall not exceed 7 Ft. A pressure and temperature Kit shall be provided with the ability to read differential pressure from 0-75 PSI and temperature from 0 to 20 deg centigrade. The valve shall be suitable for flange connection .Note: Slight variation in specifications from one make to another is acceptable.
Supply, fixing, testing and commissioning in position the 200mm dia Motorized 3 Way modulating proportional linear type mixing valve with Flow switch, Thermostat & Controller condenser pipe header having manual over ride facility with proportional thermostat and wiring with 1.5 sq mm copper conductor multi core armoured cable, 3 way valve size suitable for following GPM including actuator of suitable size complete with transformer etc complete all as specified and as directed Note: Proportional thermostat is included in AHU. The rate quoted by the contractor is for 3 way valve and actuator.
Supply, fixing, testing and commissioning in position the Pot Strainer 150 mm with pot dia 540mm fabricated out of MS sheet have a removable bronze/ stainless steel minimum 1mm thick screen with 3 mm perforations and permanent magnet.Strainers shall be provided with flanges or threaded sockets as required complete all as specified.
Supply, fixing, testing and commissioning in position the Temperature Gauges shall be Stem type thermometer , case and bezel material of construction shall be aluminium 304, weather proof as per IP 65.Immersion length around 200 mm, connection with SS 304 thermowells protection duly filled with glycerin/equivalent. complete all as specified and as directed.
Supply, fixing, testing and commissioning in position the Pressure Gauge plug complete with fittings , isolation valve etc. complete as reqd.(with out pressure gauge) complete all as specified and as directed.
Supply, fixing, testing and commissioning in position the automatic air vent Purging valve of size 25mm for pipes up to 100mm dia pipe and 40mm for larger pipes dia suitable for operating pressure at 3.5 to 4 bar complete with fittings viz nipple,elbow,tee, bend,socket etc with ball valve complete all as specified and as directed.
Supply, fixing, testing and commissioning in position the Screwed plug for 200 mm condenser water pipe complete all as specified and as directed.
Supply,installation,testing and commissioning of Unidirectional Laminar Air Flow OT Plenum Ceiling terminal box of outer dimension size 2500mm W X 2500mm D and 800mm H .The air sealed pressure chamber shall be constructed out of 1.2 mm thick SS 304 sheet having 8 nos. of hepa filters. The hepa filter area shall be 2300mm W x 2300 D (approx).The hepa filters having dust spot efficiency of 99.99% 0.3 micron installed in zero leakage Aluminum made frame .HEPA filters EU-13 / (MERV-17) of H14 Grade 99.99% efficiency are used to ensure high quality clean air is supplied and under tight control of bacterial infection system.OT plenum shall be designed at minimum at 25-35 CFM per Sq.Ft of supply air diffuser outlet terminal velocity (As per ASHARE 170 guideline) suitable for CFM mentioned in tender drawing.Air & Light diffuser made of mono filament precision woven polyester for the plan air ceiling to give a ʺLAMINAR FLOWʺ of filtered air. It also provides a diffused shadow less lighting system with Intensity control.All necessary supporting Aluminum made structure , Aluminum made hangers,Aluminium made nut ,bolts, washers, Aluminum made channels,Aluminum made fasteners etc. shall be part of scope of supply complete all as specified and as directed. Note :(i) The contractor shall submit the GA drawing with technical specification before ordering for the OT plenum.
Supply and fix laminar flow supply air diffusers with volume control damper made of aluminium of suitable thickness as per approved standard, in supply air tappings to plenum.Laminar supply air diffusers shall be made of 2mm thick powder coated aluminium sheet duly insulated with 5mm thick closed cell polyethylene foam insulation having factory laminated aluminium foil and joints covered with self adhesive aluminium tape and having holes 2/3 mm dia including frame work all necessary aluminium fasteners , nut ,bolts, washers, hangers and any other material required at site duly included in the scope of supply complete all as specified and as directed.
Supplying, installing, balancing and commissioning of site fabricated aluminium , rectangular/traingular, return air riser for OTs, made from 1.5 mm thickness sheet (16 gauge) sheet ,conforming to IS: 277 and IS-655 made of Class VIII GP sheet as per SMACNA Standard for medium pressure air flow, with MS angle/TDF flanges. The duct shall be complete with neoprene rubber gaskets,elbows,splitter damper vanes,hangars,supports,food grade gaskets and RTV sealant.Duct work shall be rigid and straight without kinks.All exposed ducts within the conditioned space shall have slip joints. Flanged joints shall not be used.Ducts shall be supported independently from the building structure and adequately, to keep the ducts true to shape..Hanger rods shall be of mild steel and of at least 10 mm dia for ducts upto 2250 mm size, and 12 mm dia for larger sizes.All nuts, bolts and washers shall be zinc plated steel. All rivets shall be galvanised or shall be made of magnesium - aluminium alloy. Self tapping screws shall not be used.The rectangular/traingular return air riser duly insualted as per duct thermal insulation specification complete with return air perforated grille and mini pleat HEPA in aluminium frame work and volume control damper of size 400 x 400 mm (approx) or as per site requirement as recommended by duct deisgner, fabrication of ducts/RA riser shall be carried out as per IS 655/SMACNA standard and as per approved drawings .
Item no. 20.215 contd Note for Item No. 20.206 to 20.215 Each AHU shall be provided with following facilities as under :- (i) The double skin casing panels shall be made of sandwich construction of at least 40 mm thick injected with CFC free R141b blended Poly Urethene foam insulation having density of 38-40 Kg/Cu.m and thermal conductivity of 0.02 W/m-deg K. The Casing panels(inside and outside) shall be constructed of 0.8mm preplasticized and pre-painted with PVC guard, GSS sheet on outside and 0.8mm galvanized sheet inside with Polyurethane foam insulation of density not less than 38 kg/cum injected in between by injection moulding machine and internal 15mm thick acoustic insulation. These panels shall be bolted from inside/ screwed from outside on to the framework with soft rubber gasket/ labyrinth type gasket in between to make the joints airtight.The gaskets shall be inserted within groove in extruded aluminium profile of the framework. The panels are removable type with self lubricating bearing and are fixed to the frame with self tapping screws. (ii) Frame work for each section shall also be bolted together with soft rubber gasket in between to make the joints air tight. Suitable doors with nylon handles, aluminium die-cast powder coated hinges & latches shall be provided for access to various panels for maintenance. (iii) AHU in the form of complete single unit shall also be acceptable only when access door(s) for maintenance to various sections are provided.The entire housing shall be mounted on heavy duty hot dipped galvanised steel channel frame work made out of miniumum 3 mm thick G.S. sheet. (iv) Mixing box section :Mixing box section have fresh air, return air damper.The damper shall be low leakage aerofoil design and in aluminium construction. (v) The AHU shall comprise of fresh air module with EU-4 filter and volume control damper
Item no. 20.215 contd (vi) Filter section with pre filter : Filter section with 50mm thick metal viscous/ washable synthetic type air prefilters two sets, combination of (EU-4) and (EU-3) filetrs having dust Filtration capacity 90% efficiency down to 20 microns + 10 microns(synthetic non woven, fire retardent type suported with aluminium & HDPE mesh and generally conforming to EU-4 & EU-779 specifications and mixing bag.Face velocity across these filters shall not exceed 155 MPM. (vii) CHW Cooling coil section with aluminium finned seamless solid drawn copper tubes (tubes thickness not less than 0.5mm) cooling coil of 6 row deep with copper tubes (As per OEM Equipment design) with bypass factor 0.12.Each section of the coil shall be fitted with flow and return headers to feed all the passes of the coil.The headers shall be of copper and shall be complete with water in/out connections, vent plug on top and drain at the bottom. The coil shall be designed to provide water velocity between 0.6 to 1.8 m/s in the tubes. The minimum thickness of the fins shall be 0.15 mm nominal. The no. of fins shall not be less than 4.7 per cm length of coil or 12-13 aluminium fins per inch. Fins may be of either spiral or plate type . The coil face velocity not less than 2.54 m/sec. (viii) HHW Cooling Coil Section with 2/3 Row Deep Heating Coil hacing suityable coil face area. Copper tube thickness shall be not less than 0.5mm. The no. of fins shall not be less than 4.7 per cm length of coil or 8-10 max aluminium fins per inch. Fins may be of either spiral or plate type . The coil face velocity not less than 2.54 m/sec.Pan type Humidistat and reheaters to control air humidity(20-80%) .
Supplying, installing, balancing and commissioning of site/ factory fabricated rectangular aluminium sheet metal ducts(For OTs) conforming to IS: 277 and IS-655 made of Class VIII GP sheet as per SMACNA Standard for medium pressure air flow, with MS angle/TDF flanges. Aluminium sheet will be as per ISS:737-1955 .The duct shall be complete with neoprene rubber gaskets,elbows,splitter damper vanes,hangars,supports,food grade gaskets and polysulphide sealed/RTV sealant. Duct work shall be rigid and straight without kinks.All exposed ducts within the conditioned space shall have slip joints
Item No. 20.219 contd Flanged joints shall not be used.Ducts shall be supported independently from the building structure and adequately, to keep the ducts true to shape. The support spacing shall be not more than 2 m.Duct connections to the air-handling unit shall be made by inserting a double canvas sleeve 100 mm long. All sheet metal connections, partitions and plenums required for flow of air through the filters, fans etc. shall be at least 1.80 mm thick aluminium sheets which shall be stiffened with 25 mm x 25 mm x 3 mm angle iron brace. It is mandotary to use factory fabricated ducts for minimum 90% of the ducting system. Use of Site fabricated ducts should be restricted to only 'to suit' piece.All necessary Aluminium supports using aluminium thread rods (as directed) and aluminium anchor bolts, food grade neoprene gaskets, food grade adhesive, food grade silicon sealant ,Aluminium turning vanes, splitters shall be included in the scope.No slip joint is allowed in any type of ducting.All nuts, bolts and washers shall be zinc plated steel. All rivets shall be galvanised or shall be made of magnesium - aluminium alloy. Self tapping screws shall not be used.Duct Pressure testing of all main duct and main branches as per latest SMACNA standard for permissible air leakage shall be inclusive in the cost.No smoke or light test of duct is permitted.All duct joint, corners,flanges joints etc. shall be properly covered with food grade silicon sealant for leak proof application inspite of leak proof duct joints. The fabrication of ducts shall be carried out as per IS 655/SMACNA standard and as per approved drawings .The fabrication of duct with flanges for the following sheet thickness complete all as specifed and as directed for size 0.80 mm thickness sheet (22 Gauge)
Description of all as per above item no. 20.219 but size 0.63mm thickness sheet (24 gauge) Note: (i) Details shown in drawings are for indicative purpose.The contractor shall submit duct calculation and drawings for approval (ii) The fabrication of the ducting system for air?conditioning & Ventilation shall confirm to SMACNA-1995 standards ("HVAC Duct Construction Standards - Metal and Flexible - Second Edition - 1995"-SMACNA)
Supply, fabrication, installation an testing of flexible canvass connections/Neoprene base fabric UL classified flexible connections constructed between ductable unit / dampers / ducting of required size with fire resist flexible double canvas sleeve complete.
Supplying, fixing, testing and commissioning of extruded aluminium powder coated supply air diffusers with aluminium volume control dampers with anti smudge ring and removable core complete as per specification and approved drawings and schedules.The outer shell shall not be less than 1.6 mm thick extruded section aluminium sheet. The diffuser assembly shall not be less than 0.80 mm thick extruded aluminium section .The diffuser shall have a rear set of adjustable blades, perpendicular to the face blades for deflection purposes complete all as specified.
Supplying, fixing, testing and commissioning of extruded aluminium powder coated return/exhaust air diffusers but without volume control dampers complete as per specification and approved drawings and schedules.The outer shell shall not be less than 1.6 mm thick extruded section aluminium sheet. The diffuser assembly shall not be less than 0.80 mm thick extruded aluminium section. The diffuser shall have a rear set of adjustable blades, perpendicular to the face blades for deflection purposes complete all as specified.
Supplying, fixing, testing and commissioning of powder coated extruded aluminium return air grills with front louvres but without volume control dampers complete as per specification and approved drawings and schedules.The outer framework of the grilles shall be made of not less than 1.6 mm thick aluminium sheet.The louvers shall be of aerofoil design of extruded aluminium section with minimum thickness of 0.8mm at front and shall be made of 0.8mm thick aluminium sheet. Louvers may be spaced 18 mm apart complete all as specified.
Supplying, installation, testing and commissioning of GI construction fresh air louvers with min.60 % free area , bird screen and fresh air filters and painted in baked enamel shade with metallic frame work complete as per specification approved drawings and schedules.Equally spaced supports and stiffeners shall be provided to prevent sagging/ vibrating of the louvers, at not more than 750mm centres where the louver's length is longer than 750mm.A bird wire screen made of 12 mm mesh in 1.6 mm steel wire held in angle or channel frame shall be fixed to the rear face of the louver frame by screens complete all as specified.
Supplying , Installing, testing and commissioning of powder coated extruded aluminium exhaust air louvers with min.60 % free area , with metallic frame work & fixing accessories , to be fixed on external wall to exhaust air from basement area to ambient , it shall be suitable for exhausting required air in CFM . Louvers need to be suitable in order avoid rain water entry in to basement @ 15 degree deflection with bird screen complete as per specification approved drawings and schedules
Supplying, installation, testing and commissioning of extruded aluminium fresh air louvers with frame bird screen, 50mm prefilter frame, mounted arrangement etc. as per specification complete all as specified.
Supplying, fixing, testing and commissioning of extruded aluminium powder coated supply air grills with aluminium volume control dampers with anti smudge ring and removable core complete as per specificationss and approved drawings and schedules. The grills shall have a rear set of adjustable blades, perpendicular to the face blades for deflection purposes complete all as specified.
Supplying, fixing, testing and commissioning of extruded aluminium powder coated exhaust /return air grills with volume control dampers with anti smudge ring and removable core complete as per specificationss and approved drawings and schedules.The grills shall have a rear set of adjustable blades, perpendicular to the face blades for deflection purposes complete all as specified.
Supplying , Installing, testing , balancing & fixing of powder coated extruded aluminium Exhaust/Return Air Grills of various sizes and as per specifications and approved drawings and schedules complete all as specified.
Supplying, installation, testing and commissioning of Fresh Air GI Duct Dampers with bird screen & Cowl Piece air AC complete all as specified.
Supplying, installation, testing and commissioning of two position adjustable opposed blade aluminium grill dampers in return air duct for Operation theatre complete all as specified.
Supply, installation, testing and commissioning of G.I volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws, linkages, flanges etc. The damper shall have aerofoil blade made of aluminium with rubber seal and frame work with aluminium.Transmission gears and seat if blades made of palstic PP and flow control quadrant as per specifications and as directed.The size of dampers shall be as per actual site requirement complete all as specified and directed.
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room complete all as specified and as directed .
Supply, installation, testing and commissioning of acuator for Motorized (ON-OFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room complete all as specified and as directed .
Supply, fix, test and commission of fire damper should be according to UL 555 (3.0 Hrs) fire rating of suitable size as per site requirement with motorized fire and smoke damper type in supply air duct / main branch, return air duct as and where required of required sizes. The fire damper blades shall be 3V shaped formed by roll forming using high quality 16 SWG galvanised steel coils and mounted on self lubricating brass bearing.The baldes are mounted in housing(16 SWG) by using MS turned spindles attached by means of arcwelding.The Spindle shall be made out of aluminium 12.5mm square rod and 100mm long mild steel bar. The fire damper shall be motorized and spring return type so as to close the damper automatically in the event of power failure and open the damper when power is restored. The spring return action shall be inbuilt mechanism and not externally mounted.
Item No.20.236 contd The Fire & smoke damper shall be complete with electronic temperature sensor and electrically operated actuator and interconnecting wiring between AHU & dampers .Fire dampers shall be compatible with the fire detection system of building & shall be capable of operating automatically through an electric motor on receiving signal from fire alarm panll. The fire damper shall be located in the supply / return air ducts. Fire dampers shall be CBRI tested & certified for 90 minutes rating against collapse & flame penetration as per UL 555-1995.Fire damper actuator shall be operated by individual control panel or heat signal from BMS panel/fire alarm system. The control panel should have indicator LED bulbs for damper blade movement(ON/OFF) shall be located such that the reset can be done easily complete all as specified and as directed. Necessary wiring from fire alarm panel up to AHU electric panel shallbe paid seperately & further from AHU electric panel .
Supply , fix,test and commissioning of actuator with smoke/fire sensor suitable for fire and smoke dampers motorised type.
Supplying and fixing of fire rated duct thermal insulation (for outdoor applications) using resin bonded fiber glass of density 24 kg/m3 with one side factory laminated aluminium foil 50mm thick to be wrapped around the duct. The insulation applied after 2 coats of cold setting adhesive (CPRX Compound). All joints shall be sealed with 50 mm wide self adhesive aluminium tape and covering with 0.63 mm x 19 mm GI wire mesh netting, butting all joints and laced with GI wire and finally covered with one layer of tar felt stuck with hot bitumen complete all as required and as specified.
Supply and fixing of acoustic lining of supply air duct and plenum with 25 mm thick resin bonded glass wool having density of 32 kg/m³ shall conform to IS 8183 as amended upto date.Accoustic insulation shall be stuck to inside the ducting after applying 2 coats of cold setting adhesive (CPRX Compound). The insulation is held in position with rivets or galvanised steel bolt with counter sunk heads ,25 x 25 GI section 1.5 mm thick and GI plate washers at the centre to centre distance of 600mm.The insulation shall be covered with reinforced plastic tissue paper and 0.5 mm thick perforated aluminium sheet having perforations between 20-40% fixed to inside surface of the duct with cadmium plated nuts, bolts, stick pins,CPRX compound etc complete as required and as per specifications
Supplying and fixing Accoustic insulation lining on wall of AHU Room with 50 mm thick, 32 kg/m3, rigid bonded fibreglass. Accoustic insulation shall be fixed in 610 mm x 610 mm frame work made of 25 x 50 x 50 x 50 x 25 mm made out of 0.6 mm thick GI sheet U shaped channel shall be fixed to walls leaving 610mm from floor by means of raw plugs in walls and dash fasteners in ceiling.and covered with reinforced fibre glass tissue and finished with aluminium perforated sheet having perforation between 20-40%of thickness not less than 0.8mm shall be fixed over the entire surface neatly without causing sag/ depression in between and held with screws. Sheet joints should overlap minimum 10mm.Aluminimum beading of 25mm wide and thickness not less than 1.00 mm shall be fixed on all horizontal/ vertical joints by means of screw complete all as specified and directed.
Supply, Install,testing and commission of 50 mm thick fiberglass slab insulation of 16 Kg. / Cu. M. density over the false ceiling. The fiberglass slab shall be wrapped in polyethylene bags complete all as specified and directed.
Supply, Install,testing and commissioning of 14,000 CFM / 40mm static pressure tube axial fan for STAIRCASE PRESSURIZATION floor mounted tube axial fresh air fan complete with casing. The casing shall be double skin, internally acoustically lined and constructed of galvanised steel with insulation class M1.The motor shall be suitable for 220±10% volt single phase 50 cycles AC supply Class F insulation,IE3, IP 65. Complete with supporting frame, G.I. weldmesh, inlet as well as at outlet guard, back draft dampers and spring Isolator etc. The Fan & motor shall be AMCA and Third party certified (Class F Insulation). complete With Drive Package & Necessary cabling & earthing strip for Staircase Pressurization With VFD of suitable rating and Bypass Stater Panel duly Compatable with BMS complete with all accessories and cabling all as specified and as directed.
Supply, Install,testing and commissioning of tube axial fan for LIFT LOBBY PRESSURIZATION (RIGHT/LEFT SIDE) floor mounted tube axial fresh air fan complete with casing. The casing shall be double skin, internally acoustically lined and constructed of galvanised steel with insulation class M1.The motor shall be suitable for 220±10% volt single phase 50 cycles AC supply Class F insulation,IE3, IP 65. Complete with supporting frame, G.I. weldmesh, inlet as well as at outlet guard, back draft dampers and spring Isolator etc. The Fan & motor shall be AMCA and Third party certified (Class F Insulation). complete With Drive Package & Necessary cabling & earthing strip for lift lobby Pressurization With VFD of suitable rating and Bypass Stater Panel duly Compatable with BMS complete with all accessories and cabling all as specified and as directed. for 3,000 CFM/40mm static pressure.
Supply, Install,testing and commissioning of tube axial fan for LIFT LOBBY PRESSURIZATION (RIGHT/LEFT SIDE) floor mounted tube axial fresh air fan complete with casing. The casing shall be double skin, internally acoustically lined and constructed of galvanised steel with insulation class M1.The motor shall be suitable for 220±10% volt single phase 50 cycles AC supply Class F insulation,IE3, IP 65. Complete with supporting frame, G.I. weldmesh, inlet as well as at outlet guard, back draft dampers and spring Isolator etc. The Fan & motor shall be AMCA and Third party certified (Class F Insulation). complete With Drive Package & Necessary cabling & earthing strip for lift lobby Pressurization With VFD of suitable rating and Bypass Stater Panel duly Compatable with BMS complete with all accessories and cabling all as specified and as directed. for 6,000 CFM/40mm static pressure. Note for Item No.20.236 to 20.244 :(i) Contractor shall submit CFM calculation details as per ASHRAE ventilation standard for approval (ii) Contractor shall verify static pressure from drawings during pre ordering stage and submit calculations for fan actual static pressure , in the event of any variation in static pressure as mentioned above, the same to be provided by contractor without incurring additional cost to dept.(iii) Provision for controlling of fan via VFD and arrangement for the fan to run on normal starter/standalone controller in case of VFD failure included in the cost of item.
Supply, Install,testing and commissioning of Tube Axial Air Exhaust Air Fans complete with casing. The casing shall be double skin, internally acoustically lined and constructed of galvanised steel with insulation class M1.The motor shall be suitable for 220±10% volt single phase 50 cycles AC supply Class F insulation,IE3, IP 65. Complete with supporting frame, G.I. weldmesh, inlet as well as at outlet guard, back draft dampers and spring Isolator etc. The Fan & motor shall be AMCA and Third party certified (Class F Insulation). complete With Drive Package & Necessary cabling & earthing strip & Filter for the following Capacities :As per AMCA210 standard "Laboratory Methods of testing fans for rating" Balancing quality - As per AMCA204 / ISO 1940 standard With VFD of suitable rating and Bypass Stater Panel duly Compatable with BMS complete with all accessories and cabling , fire Rating 300° C for minimum 60 minutes, suitable to work on various modes, sound attenuator Piece for sound abosorption included complete all as specified and as directed for 11500 CFM / 40mm static pressure- 2 Nos. Of Fans. (1 Fans are working When Normal Mode & All Are fans Are Working In Case Of Fire Mode) .
Item no. 20.245 contd Note :(i) Contractor shall submit CFM calculation details as per ASHRAE ventilation standard for approval (ii) Contractor shall verify static pressure from drawings during pre ordering stage and submit calculations for fan actual static pressure , in the event of any variation in static pressure as mentioned above, the same to be provided by contractor without incurring additional cost to dept.(iii) Provision for controlling of fan via VFD and arrangement for the fan to run on normal starter/standalone controller in case of VFD failure included in the cost of item
Supply, installation and adjusting of disc valve 150mm dia suitable for exhausting toilet foul air ,comprising of an adjustable centre cone and coupling sleeve made of Aluminum sheet duly epoxy painted with approved color. The disc valve shall be fitted with a galvanised steel installation frame and the sleeve shall incorporate a foam-rubber gasket for airtight sealing. The centre cone should be adjustable for balancing and with a locking arrangement to maintain the desired flow rate complete all as specified and directed.
Supply, installation, testing and commissioning of LT panel indoor type floor mounted ( Main Panel, Location : AC Plant Room) cubical type BMS compatible design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, fully interlocked electrically and mechanically, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 100mmX 75mmX 5 mm thick, fabrication shall be done in transportable sections. The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm.
item no. 20.247 contd The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for suitable for eletric load complete as required and comprising of the following:- (A) (i) TPN + E Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB/ACB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three.(iv) MCB SP 6A 'C' series for control ckt protection = 03Nos
item no. 20.247 contd (B). INCOMER (i) ACB 1000 A, 4P, 415V, 50kA , lcs =100% lcu confirm to IEC/IS – 60947-2, with microprocessor based adjustable overload 50-100%, adjustable short circuit in range of 400% to 100% of ACB rating and earth fault protection have adjustable current setting of 20% to 100% of rated capacity complete with with integral LCD Display of load current and individual loading of all the three phases including closing and trip coils (Shunt release + Under voltage release) and protection against , over current, shor circuit,over voltage and earth fauly.ACB shall be electronic draw out type modular in construction confirming to IEC947/IS:13947(part 2) ,VDE 0660 Part 101,IEC 68 Part 2-30(Climate proof).The ACB release shall be self powered with true RMS sensing. The ACB shall be with 230 V AC shunt trip coil and 230 V, AC Motor wound spring closing mechanism.Specific LED indications should be provided for short circuit, over current and earth fault operation for faster fault diagnosis - 01 nos (ii) Surge arrester 2kVp,75kA rated surge arrestor suitable fo both lightning and switching surges,complete with suitable protection fuse (inbuilt) along with 160A, 36kA, FP, MCCB (Thermal magnetic based) and surge counter- 1 No (C). OUTGOING (a) Chiller Unit : (i) MCCB 250 Amp 4 pole, 36 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with adjutsable magnetic and adjustable thermal release, adjustable overload 65% to100% and adjustable short circuit release from 3.5 to10 ln setting complete with phase seperator - 03 Nos
item no. 20.247 contd (b) Hot water Generator and Hot water Pumps : (i) MCCB 400 Amp 4 pole, 36 KA, lcs =100% lcu, microprocessor release ,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) Adjustable Overload, Short-circuit, Ground fault (4 Pole) & Fixed Instantanous Netural Protection (4 Pole), adjustable overload release 70% to100% and adjustable short circuit release from up to 10 ln setting complete with phase seperator - 02 Nos (ii) Motor protection circuit breaker(MPCB) toggle/ rotary type , 06-10 Amp, FLC - 6.10 Amps with thermal magnetic multifuntion release ,3phase AC 50 Hz,din rail mounted,conforming to IEC 60947-4-1,Breaking capacity Icu 100 KA and Rated service short-circuit breaking capacity Ics 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, under voltage release ,Shunt release,IK09 enclosure,Instantaneous Over Current release shall be 12 times of Rated current,IP20 conforming to IEC 60529, short circuit and thermal overload protection facility complete with bus bar spreaders all as specified - 02 Nos (iii) Fully automatic star delta starter ( By pass in case MPCB failure) 06-10 Amp, suitable for 415V, AC, 50 hz supply or as per motor rating in hp or as per full rated current of motor complete with protection and other accessories as required -01 nos (iv)Start/Stop/Reset push buttons -04nos(02 nos for each motor)(v) Phase indication/Motor ON/Motor OFF/Trip indicating lamps LED type -01set (vi)Auxillary control relays -01 set (vii) Surge Supressor 415 volts 20 KA -01 nos(viii) Protections:- Phase failure, unbalance, phase sequence , overloading and dry running(under current) (ix) 3 pole Power contactors,AC 3 type, suitabel size confirming to IS/IEC 60947-4-1 suitable for 3 phase 415Volts,50Hz AC supply with auxillary contact 1NO + 1 NC for motor operation -02nos or as per requirement of panel designer
item no. 20.247 contd Note: The MPCB current and voltage rating must match the name plate voltage and current rating of the motor. The starter shall have necessary protection device whose settings and ratings shall be as per the type-2 co-ordination chart. (c ) Cooling Tower : (i) MCCB 40 Amp 4 pole, 16 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator -03 nos( 02 nos working + 01 nos stand by) (d) Pumps CHW Pumps Primary : (i) MCCB 63 Amp 3 pole, 25 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator - 03 nos. (ii) Motor protection circuit breaker(MPCB) toggle/ rotary type , 30 - 40 Amp, FLC - 36Amps with thermal magnetic multifuntion release ,3phase AC 50 Hz,din rail mounted,conforming to IEC 60947-4-1,Breaking capacity Icu 100 KA and Rated service short-circuit breaking capacity Ics 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, under voltage release ,Shunt release,IK09 enclosure,Instantaneous Over Current release shall be 12 times of Rated current,IP20 conforming to IEC 60529, short circuit and thermal overload protection facility complete with bus bar spreaders all as specified - 03 Nos (iii)Start/Stop/Reset push buttons -09nos(03 nos for each motor)(iv) Phase indication/Motor ON/Motor OFF/Trip indicating lamps LED type -01set (v)Auxillary control relays -01 set (vi) Surge Supressor 415 volts 20 KA -01 nos
item no. 20.247 contd (vii) Protections:- Phase failure, unbalance, phase sequence , overloading and dry running(under current) (viii) 3 pole Power contactors,AC 3 type, suitabel size confirming to IS/IEC 60947-4-1 suitable for 3 phase 415Volts,50Hz AC supply with auxillary contact 1NO + 1 NC for motor operation -03nos or as per requirement of panel designer Note: The MPCB current and voltage rating must match the name plate voltage and current rating of the motor. The starter shall have necessary protection device whose settings and ratings shall be as per the type-2 co-ordination chart. CHW Pumps Secondary :(i) MCCB 100 Amp 3 pole, 25 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator -03 nos. CDW Pumps :(i) MCCB 100 Amp 4 pole, 25 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator -03 nos.(ii) Motor protection circuit breaker(MPCB) toggle/ rotary type , 37 - 50 Amp, FLC - 43Amps with thermal magnetic multifuntion release ,3phase AC 50 Hz,din rail mounted,conforming to IEC 60947-4-1,Breaking capacity Icu 100 KA and Rated service short-circuit breaking capacity Ics 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2, under voltage release ,Shunt release,IK09 enclosure,Instantaneous Over Current release shall be 12 times of Rated current,IP20 conforming to IEC 60529, short circuit and thermal overload protection facility complete with bus bar spreaders all as specified - 03 Nos
item no. 20.247 contd iii)Start/Stop/Reset push buttons -09nos(03 nos for each motor)(iv) Phase indication/Motor ON/Motor OFF/Trip indicating lamps LED type -01set (v)Auxillary control relays -01 set (vi) Surge Supressor 415 volts 20 KA -01 nos(vii) Protections:- Phase failure, unbalance, phase sequence , overloading and dry running(under current) (viii) 3 pole Power contactors,AC 3 type, suitabel size confirming to IS/IEC 60947-4-1 suitable for 3 phase 415Volts,50Hz AC supply with auxillary contact 1NO + 1 NC for motor operation -03nos or as per requirement of panel designer Note: The MPCB current and voltage rating must match the name plate voltage and current rating of the motor. The starter shall have necessary protection device whose settings and ratings shall be as per the type-2 co-ordination chart. (e) Pressurization unit ( Chilled and Hot water) : (i)MCB TPN C series 25 Amp,10KA - 02 Nos( 01 working + 01 S/B) (ii) MCB TPN C series 16 Amp,10KA - 02 Nos( 01 working + 01 S/B) (f) AHU 1 to 8 : (i) MCCB 160 Amp 4 pole, 36 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with adjustable magnetic and adjustable thermal release, adjustable overload 65% to100% and adjustable short circuit release from 3.5 to10 ln setting complete with phase seperator - 02 Nos(01 nos working + 01 nos Stand by) (g) AHU Ground Floor : (i) MCCB 63 Amp 4 pole, 25 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator - 01 nos + 01 nos(Stand by) - 2 nos (AHU No.1)
Supply, installation, testing and commissioning of LT panel indoor type floor mounted ( Main Panel for OT 1 to 8, Location : Terrace AHU Room) cubical type BMS compatible design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, fully interlocked electrically and mechanically, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections. The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm.
item no. 20.248 contd The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for suitable for eletric load complete as required and comprising of the following (A) (i) TPN + E Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB/ACB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three.(iv) MCB SP 6A 'C' series for control ckt protection = 03Nos
Supply, installation, testing and commissioning of LT panel indoor type wall mounted for OT AHUs (BMS compatible) design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP55 as per IS-2147 of 1962 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA shee having provision for entry of armoured cable of adequate size complete with stiffeners wherever required.
item no. 20.249 contd The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided. EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support , air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for operation of motors for air handling units/ Heat recovery wheel/Ventilation fans / pumps complete as required and comprising of the following:- (A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB/ACB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three.(iv) MCB SP 6A 'C' series for control ckt protection = 03Nos
Supply, installation, testing and commissioning of LT panel indoor type wall mounted for Ground Floor AHU No.1(BMS compatible) design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP55 as per IS-2147 of 1962 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA shee having provision for entry of armoured cable of adequate size complete with stiffeners wherever required.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.
item no. 20.250 contd EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support , air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for operation of motors for air handling units/ Heat recovery wheel/Ventilation fans / pumps complete as required and comprising of the following:- (A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB/ACB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three.(iv) MCB SP 6A 'C' series for control ckt protection = 03Nos
Supply, installation, testing and commissioning of LT panel indoor type wall mounted for Ground Floor AHU No.2(BMS compatible) design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP55 as per IS-2147 of 1962 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA shee having provision for entry of armoured cable of adequate size complete with stiffeners wherever required.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.
item no. 20.251 contd EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support , air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for operation of motors for air handling units/ Heat recovery wheel/Ventilation fans / pumps complete as required and comprising of the following:- (A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB/ACB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three.(iv) MCB SP 6A 'C' series for control ckt protection = 03Nos
Supply, installation, testing and commissioning of LT panel indoor type wall mounted for First Floor AHU(BMS compatible) design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP55 as per IS-2147 of 1962 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA shee having provision for entry of armoured cable of adequate size complete with stiffeners wherever required.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.
item no. 20.252 contd EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support , air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for operation of motors for air handling units/ Heat recovery wheel/Ventilation fans / pumps complete as required and comprising of the following:- (A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB/ACB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three.(iv) MCB SP 6A 'C' series for control ckt protection = 03Nos
item no. 20.252 contd (ix)Auxillary control relays -01 set , Surge Supressor 415 volts 20 KA -01 nos, Protections:- Phase failure, unbalance, phase sequence , overloading and dry running(under current) and 3 pole Power contactors,AC3 type, suitable size confirming to IS/IEC 60947-4-1 suitable for 3 phase 415Volts,50Hz AC supply with auxillary contact 1NO + 1 NC for motor operation -02nos or as per requirement of panel designer .
Supply, installation, testing and commissioning of LT panel indoor type wall mounted for second Floor AHU (BMS compatible) design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP55 as per IS-2147 of 1962 with pre-treatment through 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA shee having provision for entry of armoured cable of adequate size complete with stiffeners wherever required.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.
item no. 20.253 contd EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support , air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for operation of motors for air handling units/ Heat recovery wheel/Ventilation fans / pumps complete as required and comprising of the following:- (A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB/ACB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three.(iv) MCB SP 6A 'C' series for control ckt protection = 03Nos
Supply, Installation , Testing and commissioning of prefabricated type cable tray fabricated out of MS perforated hot dip galvanized sheet of minimum 1.6mm thick (galvanisation thickness not less than 50 microns).The perforation not more than 17.5%. The cable tray suspended from the ceiling with MS suspenders at a distance not mote than 2.50m and near every juction/joint etc.The 50mm flange to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers etc. site condition and rate shall include cost of anchor fastners, screw, nuts, bolts and misc. and other fixing hardware painting of support structure etc as required complete all as specified and as directed for 100 mm width x 50 mm depth x 1.6 mm thickness
Supply, Installation , Testing and commissioning of prefabricated type cable tray fabricated out of MS perforated hot dip galvanized sheet of minimum 1.6mm thick (galvanisation thickness not less than 50 microns).The perforation not more than 17.5%. The cable tray suspended from the ceiling with MS suspenders at a distance not mote than 2.50m and near every juction/joint etc.The 50mm flange to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers etc. site condition and rate shall include cost of anchor fastners, screw, nuts, bolts and misc. and other fixing hardware painting of support structure etc as required complete all as specified and as directed for 150 mm width x 50 mm depth x 1.6 mm thickness
Supply, Installation , Testing and commissioning of prefabricated type cable tray fabricated out of MS perforated hot dip galvanized sheet of minimum 1.6mm thick (galvanisation thickness not less than 50 microns).The perforation not more than 17.5%. The cable tray suspended from the ceiling with MS suspenders at a distance not mote than 2.50m and near every juction/joint etc.The 50mm flange to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers etc. site condition and rate shall include cost of anchor fastners, screw, nuts, bolts and misc. and other fixing hardware painting of support structure etc as required complete all as specified and as directed for 225 mm width x 50 mm depth x 1.6 mm thickness
Supply, Installation , Testing and commissioning of prefabricated type cable tray fabricated out of MS perforated hot dip galvanized sheet of minimum 1.6mm thick (galvanisation thickness not less than 50 microns).The perforation not more than 17.5%. The cable tray suspended from the ceiling with MS suspenders at a distance not mote than 2.50m and near every juction/joint etc.The 50mm flange to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers etc. site condition and rate shall include cost of anchor fastners, screw, nuts, bolts and misc. and other fixing hardware painting of support structure etc as required complete all as specified and as directed for 300 mm width X 50 mm depth X 1.6 mm thickness
Supply, Installation , Testing and commissioning of prefabricated type cable tray fabricated out of MS perforated hot dip galvanized sheet of minimum 1.6mm thick (galvanisation thickness not less than 50 microns).The perforation not more than 17.5%. The cable tray suspended from the ceiling with MS suspenders at a distance not mote than 2.50m and near every juction/joint etc.The 50mm flange to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers etc. site condition and rate shall include cost of anchor fastners, screw, nuts, bolts and misc. and other fixing hardware painting of support structure etc as required complete all as specified and as directed for 450 mm width x 50 mm depth x 2 mm thickness
Supply and Fixing XLPE insulated and PVC sheathed,armoured galvanised wire,1100 volts grade copper conductor cable Extruded PVC Type ST2 Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988.complete all as required and specified for the sizes of cables 3C X 10 sqmm copper conductor, 2XWY/2XFY
Supply and Fixing XLPE insulated and PVC sheathed,armoured galvanised wire,1100 volts grade copper conductor cable Extruded PVC Type ST2 Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988.complete all as required and specified for the sizes of cables 3C X 6 sqmm copper conductor, 2XWY/2XFY
Supply and Fixing XLPE insulated and PVC sheathed,armoured galvanised wire,1100 volts grade copper conductor cable Extruded PVC Type ST2 Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988.complete all as required and specified for the sizes of cables 3C X 4 sqmm copper conductor, 2XWY/2XFY
Supply and Fixing XLPE insulated and PVC sheathed,armoured galvanised wire,1100 volts grade copper conductor cable Extruded PVC Type ST2 Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988.complete all as required and specified for the sizes of cables 3C X 2.5sqmm copper conductor, 2XWY/2XFY
Supply and Fixing XLPE insulated and PVC sheathed,armoured galvanised wire,1100 volts grade copper conductor cable Extruded PVC Type ST2 Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988.complete all as required and specified for the sizes of cables 4C X 6 sqmm copper conductor, 2XWY/2XFY
Supply and Fixing XLPE insulated and PVC sheathed,armoured galvanised wire,1100 volts grade copper conductor cable Extruded PVC Type ST2 Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988.complete all as required and specified for the sizes of cables 4C X 4 sqmm copper conductor, 2XWY/2XFY
Supply and Fixing XLPE insulated and PVC sheathed,armoured galvanised wire,1100 volts grade copper conductor cable Extruded PVC Type ST2 Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988.complete all as required and specified for the sizes of cables 4C X 10 sqmm copper conductor, 2XWY/2XFY
Supply and Fixing XLPE insulated and PVC sheathed,armoured galvanised wire,1100 volts grade copper conductor cable Extruded PVC Type ST2 Sheathed, 650 V/1100 V Grade as per IS 7098 (Part 1) 1988.complete all as required and specified for the sizes of cables 2C X 2.5 sqmm copper conductor,2XWY/2XFY
Supply of Miscellaneous items as under:- Digital thermometer and Humidistat are to be provided in Rooms as directed by Engr in charge - 1 Set (Each set consists of digital thermometer and digital humidistat)
Supply of Miscellaneous items as under:- Normal Twin sets of Dry/Wet Bulb thermometers in other rooms
Supply of Miscellaneous items as under:- Schematic diagram of plant details on a luminous Flourescent sheet as directed by Engr-in-charge.
Supply of Miscellaneous items as under:- Portable fire extenguisher CO2 type 3 kg capacity
Supply and making and termination with brass compression gland and aluminium lugs for XLPE insulated PVC sheathed armoured aluminimum/copper conduteor cable of 1.1 KV grade confirming to IS - 7098 Part-1 as required. all as specified and as directed for the sizes 3C X 4 sqmm copper conductor, 2XWY
Description all as per item no. 20.271 but size 3C X 6.0sqmm copper conductor, 2XWY
Description all as per item no. 20.271 but size 2C X 1.5sqmm copper conductor, 2XWY
Description all as per item no. 20.271 but size 3C X 2.5sqmm copper conductor, 2XWY
Description all as per item no. 20.271 but size 3C X 10.0sqmm copper conductor, 2XWY
Description all as per item no. 20.271 but size 3.5C X 95sqmm aluminium conductor
Description all as per item no. 20.271 but size 3.5C X 25sqmm aluminium conductor
Description all as per item no. 20.271 but size 3.5C X 120sqmm aluminium conductor
Description all as per item no. 20.271 but size 3.5C X 50sqmm aluminium conductor
Description all as per item no. 20.271 but size 3.5C X 70sqmm aluminium conductor
Description all as per item no. 20.271 but size 4C X 4 sqmm copper conductor, 2XWY
Description all as per item no. 20.271 but size 4C X 6.0sqmm copper conductor, 2XWY
Description all as per item no. 20.271 but size 4C X 10.0sqmm copper conductor, 2XWY
Description all as per item no. 20.271 but size 3.5C X 35.00sqmm copper conductor, 2XWY
Material and labour for dismantling , shifting, assembling,refixing, testing and commissioning of complete existing air cooled package type ducted floor mounted air conditioning plant of nominal cooling capacity of 44.0TR(02 units x 22 TR each) Make: Blue star" suitable for 415V, Three Phase, 50 Hz, AC supply complete with indoor and oudoor unit, connected copper piping and valves, diffusers/grills, drain pipe, control panel and control wiring from existing medical store to temporary location within 60m as per direction of Engr-in-charge under Phase-I and from temporary location to designated place at proposed accidental and emergency bldg under Phase-II.Each amchine shall have 11.0TR(132000 Btu/hr) nominal cooling capacity shall be consists of (a) Indoor unit of size 1160mm(W) X 660mm(D) X 1700mm(H) comprising of Centrifugal Forward Curved Double Inlet Double Width blower, Hermetically Sealed Scroll compressors suitable for R407C refrigerant delivering actual capacity duly installed at site,Non Woven Polyester Midea Enclosed by HDPE Mesh filter and Microprocessor based with LCD Display, (b)Outdoor unit of size 1020mm X 420mm X 950mm comprising of Air-Cooled FTHX type condenser with Propeller type centrifugal fan.(c) Suction and discharge copper refrigerant piping of suitable size and length between indoor and outdoor unit.(d) Electric connection between between indoor and outdoor unit.(d) Duct fire and smoke damper etc. complete all as specified and as directed. The air cooled package type ducted air conditioning plant shall be a able to maintain the required inside conditions(Temperature and Humidity) as per ASHRAE/ISHRAE standard wit respect to ambient condition at Chakeri, Kanpur 109°F(42.8°C) DBT & 74.2°F(23.45°C) WBT .
Taking down Gi sheet with TDF flange rectangular/square duct made out of 'L' shaped hollowed profile,duly factory boxed incl all accessories such as corner,cleat,carriage bolt gasket,crosslink XLPE foam nitrile rubber,cloth lining, grill etc complete from old medical store of size 22 gauge all as specified and directed.
Taking down old unserviceable XLPE insulated,screened PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional 95 sqmm 3.5 core from laid in trenches/ducts/encased in GI pipe/fixed to pole at old medical store and deposit to MES store yard, all as specified and directed.
Supply, install, testing and commissioning ot tube axial fan for centrlised exhaust/ventilation of toilet, wall mounted tube axial fresh air fan complete with casing, including required ducting and return air grill/diffuser. The casing shall be double skin, internally acoustically lined and constructed of galvanised steel with insulation class M1. The motor shall be suitable for 220 ± 10% volt single phase 50 HZ AC supply Class F insulation, IE3, IP 65 cpmplete with supporting frame, GI weld mesh, inlet as well as outlet guard and necessary cabling and earthing strip for common toilet at each floor with all accessories and cabling all as specified and directed for 3000 CFM/40mm static pressure. Note:- Ducting and return air grill/diffuser shall be measured & paid seperately under respective items.
Supply , installation , testing & commissioning of AHRI / EUROVENT certified water cooled Screw type water chilling machine each having a minimum capacity of 150 TR (actual) with Single /Multiple Compressors independent circuit with VFD driven semi hermetic sealed screw type compressor suitable for R143a refrigerant delivering actual capacity as per the following parameters duly installed at site. The chiller unit should be complete with semi hermetic / hermetic sealed screw type compressor , Electronic Expansion Valve, shell and tube water cooled condenser , DX/Flooded insulated shell and tube evaporator including victaulic couplings(Inlet/outlet) complete with Flanged End Piping Connections also with Water Flow Switch at the chiller, BMS interface unit Modbus, Interconnected Refrigerant Copper Piping, R143a Pre Charged Refrgierant . A factory assembled with starter panel mounted on the chiller including the disconnect switch suitable for 50 Hz, 3 phase 360v to 415v,ac supply. The unit shall have filter dryer, pressure switch i.e. HP/LP and electronic thermostats. The Unit mounted starter panel with double door construction shall be single power point type complete with IP 55 degree of protection, consisting of power disconnecting switches with fuses/ MCCBs, VFD for Motors and condenser Fan Motors complete with Under/Over voltage and phase reversal protection, Single Phase Preventers, communication card which can accept 4-20 mA or 2-10 V dc analog signal, compressor restart protection,10sec time delay between system and 5°C anti-freeze protection . Automatic and safety control mounted in central console electronic Micro Processor Plant Manager all as supplied by OEM as part of Chiller Package compatible with building control Unit for Integration with External Building Management System. Lubrication device consisting of automatic electric oil pump, oil cooler, head tank, oil strainer, and automatic pressure regulating valve, oil heater, oil heater thermal switch etc. as per specifications. The Neoprene Pad type Vibration Isolators shall be provided alongwith chillers. Chiller shall be factory tested at design conditions at 100%, 75%, 50% and 25% load. The unit shall be tested as per ARI 550/590- standard .Chilling machine described above, as per specifications and complete in all respects for the operating parameters as given under:-
Design, Supply, installation, testing and commissioining of Induced draft counter flow FRP cooling tower Cap 375 TR (minimum) CTI certified of suitable heat rejection capacity,multi cell/single cell operation, with FRP water basin PVC fills, water distribution arrangement with self rotating sprinklers or fixed nozzles of PVC construction, with direct driven/ belt driven fans ,VFD drive for fan operation,Galvanised hardware complete with sump connection with suitable valve, PVC fill thickness not less than 0.2mm, louvers, drift eiliminator complete,statically and dynamically balanced multi blade axial flow fan direct driven, TEFC IE3 motor as per IS 12615,IP-55 protection motor, suction screen, make-up and quick fill arrangement, overflow and drain connections, suitable GI inspection ladder, steel supporting structure, antivibration mounting etc, complete as per manufacturer's design/specifications isolating switch and other accessories to make it fully operational and maintainable & positioning of cooling tower at location as shown on drawings.The cooling towers shall be supplied with the manufacturer‘s standard finish painting.The cooling tower shall meet criterion as per ASHRAE standard 90.1-2004.The Cooling tower motor drive shall be powered by VFD of suitable rating ,shall be capable to communicate effectively with BMS with following facility as under:-
HOT WATER SUPPLY
Supply and fix Non return vlave 25mm bore , screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed byEngr-in-charge
COOLING APPLIANCES
Supply and fix desert cooler Steel body electric driven (single phase), 220Volts, 50 HZ, Suitable exhaust motor of size 350 mm sweep incl water pump, ON OFF switch, Four step speed regulator (0-100%) having nominal air flow capacity of 5000 CuM per hour (or nearest size) and incl PVC connection Pipe of suitable length and float valve complete all as directed by Engr -In- Charge.
S & F Refrigerator,direct cool,BEE 5 star rating , single door, operated range 190volts - 230 volts, 50Hz AC Supply of 195 Ltrs capacity ,digital inverter compressor ,complete with stabilizer free operation including all accessories complete all as specified and directed by Engr-in -charge.
Supply and fix RO plant(Purifier) of output capacity 25 Ltrs per hour with pre filter including pipework and all accessories complete all as specified and directed by Engr-in -charge.
OT LIGHTS
Supply and fix Shadow less light fitting complete with emergency power unit & battery back up for min 30 minutes (3 KVA), having dome of 810 mm dia, fully counter balanced moveable on ceiling trolley having a minimum longitudinal travel of 1350 mm and axial rotation of 360 deg. The unit to be suitable for operation on 230 V, single phase 50 cycles mains supply. (For Major OT having lux level> 120,000)
Supply and fix mobile Shadow less OT light fitting complete with emergency power unit & battery back up for min 30 minutes (3 KVA), having dome of 810 mm dia, fully counter balanced and fixed on suspension rod, capable for operation on 230 V single phase, 50 cycles mains supply having lux level > 70,000.
Supply,Installation, Testing and Commissioning of 36W to 44W LED Peripheral lights cum clean room (OT) luminaire, dimension 600 x 600 mm, colour temperature 4000K, CRI > 90 , Energy class A++,surface mounted recess lights, IP54 Protocol, Non hygroscopic , the peripheral lights having power LED elements with suitable electronic driver and controls.The light framed cover shall be made of highly resistant and disinfectant consistent, bottom opening and screwless system. The Peripheral light diffuser is fixed in powder coated aluminium frame of suitable size complete all as specified and as directed.
Supply, installation, testing & commissioning of hospital Passenger cum Bed / Stretcher lift machine room less electrically operated with modular microprocessor based controls, complete with power driven automatic center opening with 18 SWG stainless steel (SS) moon rock finish sliding car doors and landing doors having stainless steel (SS) car enclosure suitable to carry 20 passenger lifts (1360 kgs) at speed of 1.0 M/Sec to serve upto 3 floors (G+2) ,full collective operation with all standard features mentioned below and human interface device (HID) and along with (ARD) automatic resucue device confirming to NBC 2016, IS 14665 (Part-1): 2000 and IS 14665 (Part-2/Sec 1 &2) & (Part-3/Sec 1 &2) : 2000( latest edition and amendment up to date) complete all as specified and l as per following technical specification of
Item No. 20.299 contd (m)Fan : Pressure fan, 400 mm sweep-01 No. Brake: Braking of the lift will be done by electronically varying the voltage and the frequency of motor feeding current (variable Voltage and Variable frequency control) i.e., VVVF control (n)Car Entrance: Automatic centre opening in stainless steel hairline finish. (o)Door Opening: Center opening doors 1100mm W x 2400mm H with provision of emergency key opening at all landings.SS car door finish with 2 hr. fire resistance door duly supported by valid test certificate issued by NABL accredited or Independent test laboratory.Car door lock compatible. (p)Door Operation: Automatic power operation with adjustable door opening and closing timings.Variable speed high-traffic door operator (q)Monitoring: Pulse 24/7 belt integrity monitoring system and Automated rescue operation (r)Suspension : Lubrication free,Stainless steel polyurethane-coated belts. (s)Indicators: Hall position indcators for car & landing Direction and position indicator with stainless steel fixtures at all floor. (t) Over Head available/Required for 1 m/s: ( car height + 1900) 4600mm (u) Pit available/Required for 1 m/s :1800mm deep (v) Levelling accuracy ± 5mm independent of load in the car. (w) Guide Rails: Tounge & Groove Guide Rails The following shall also be provided in addition to above STANDARD FEATURE (i) Anti Nuisance car call protection. (ii) Automatic car return device (homelanding). (iii) Independent service ( for Simplex only). (iv) Overlaoding Device. (v) Nudging.
Item No. 20.299 contd (vi) Emenrgency fireman's service. (vii) Audio's car call button. (viii) Emergency Car light unit. (ix) High performance contact free infrared curtain door protection. (x) Door time protection. (xi) Emergency Alarm button. (xii) Extra door time of lobby & parking. (xiii) Door open close button. (xiv) Manual rescue operation . (xv) Belt inspection device 7 auto fan cut off. ADDITIONAL DEVICE Automatic rescue,infra red sensor,overload warning indicator and floor announcing system with music/ariival chime HUMAN INTERFACE DEVICE (i) Hall button with micro stroke push buttons combained with 16 signals digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push button located on side panel. (iii) Door open door closed on car operating panel. (iv) 2 way inter communication system in cabin (v) Dot matrix position indicator. (vi) Battery operated alarm well & emergency light. (vii) Fireman witch at main lobby. (viii) Manual rescue operation (ix) Call register indicator in all landings. (x) Attendant operation in car panel. (xi) Diffused Lighting fixture/LED Lighting
Item No. 20.299 contd (xii) Lighting for car operating panel with door open/close button SAFETY FEATURES Motor overheat protection , phase failure and reversal protection and features as per ISI / IS code /NBC Provision.Every lift installation shall necessarily be provided with the safety features in accordance with IS 14665(Part-4/Sec-4):2001
Supply, installation, testing & commissioning of Passenger lift machine room less electrically operated with modular microprocessor based controls, complete with power driven automatic center opening with 18 SWG stainless steel (SS) moon rock finish sliding car doors and landing doors having stainless steel (SS) car enclosure suitable to carry 10 passenger lifts (680 kgs) at speed of 1.0 M/Sec to serve upto 3 floors (G+2) ,full collective operation with all standard features mentioned below and human interface device (HID) and along with (ARD) automatic resucue device confirming to NBC 2016, IS 14665 (Part-1): 2000 and IS 14665 (Part-2/Sec 1 &2) & (Part-3/Sec 1 &2) : 2000( latest edition and amendment up to date) complete all as specified and l as per following technical specification of (a)Type & capacity : Passenger lift (Elevator for passenger lift) 10 Passenger (680 kgs). (b)Type of drive : variable voltage , variable frequency regenerative drive( Closed loop) with micro processor based controller 15 mm landing accuracy with speed encloder. (c)Speed: 1.0 meter per second.( as per IS provision) (d)Type of Machine : Gearless machine with synchronous permanent magnet motor (located in shaft on top of guide rails) (e )Rise /Travel: Suitable for travel of 9.0 meter(approx) Ground floor and first floor to second floor ( three floors, three stops, three levels and for opening on same side).
Item No. 20.300 contd (r)Indicators: Hall position indcators for car & landing Direction and position indicator with stainless steel fixtures at all floor. (s) Over Head available/Required for 1 m/s: ( car height + 1900) 4100mm (t) Pit available/Required for 1 m/s :1600mm deep (u) Levelling accuracy ± 5mm independent of load in the car. (v) Guide Rails: Tounge & Groove Guide Rails (w)Brake: Braking of the lift will be done by electronically varying the voltage and the frequency of motor feeding current (variable Voltage and Variable frequency control) i.e., VVVF control The following shall also be provided in addition to above STANDARD FEATURE (i) Anti Nuisance car call protection. (ii) Automatic car return device (homelanding). (iii) Independent service ( for Simplex only). (iv) Overlaoding Device. (v) Nudging. (vi) Emenrgency fireman's service. (vii) Audio's car call button. (viii) Emergency Car light unit. (ix) High performance contact free infrared curtain door protection. (x) Door time protection. (xi) Emergency Alarm button. (xii) Extra door time of lobby & parking. (xiii) Door open close button. (xiv) Manual rescue operation .
Item No. 20.300 contd (xv) Belt inspection device 7 auto fan cut off. ADDITIONAL DEVICE Automatic rescue,infra red sensor,overload warning indicator and floor announcing system with music/ariival chime HUMAN INTERFACE DEVICE (i) Hall button with micro stroke push buttons combained with 16 signals digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push button located on side panel. (iii) Door open door closed on car operating panel. (iv) 2 way inter communication system in cabin (v) Dot matrix position indicator. (vi) Battery operated alarm well & emergency light. (vii) Fireman witch at main lobby. (viii) Manual rescue operation (ix) Call register indicator in all landings. (x) Attendant operation in car panel. (xi) Diffused Lighting fixture/LED Lighting (xii) Lighting for car operating panel with door open/close button SAFETY FEATURES Motor overheat protection , phase failure and reversal protection and features as per ISI / IS code /NBC Provision.Every lift installation shall necessarily be provided with the safety features in accordance with IS 14665(Part-4/Sec-4):2001 Note for Item no.20.299 and 20.300 (i) Contractor shall note that the defects liability period for lift shall be three years from the cerftified date of completion on as certified by GE: During the said defects liability period, the lift shall be kept functioned serviceable all the time and all consumable items shall also be provided by contractor for runnig of the lift. (ii) The lift shall be inspected and commissioned by the lift inspector and it shall be the responsibility of the contractor to get the lift inspected & commissioned without any extra cost to the department.
Item No. 20.300 contd (iii) Cost of the above provisions shall be deemed in the rates quated by contractor. (iv) All dimensions given above are recommended dimensions . In the event of any variations mutually agreed between manufacturer and purchaser are permitted. However, variation in car inside dimensions shall be within the maximum area limits specified in 1S 14665 (Part 3/Sec 1). (v) Dimensions of pit depth and overhead may differ in practice as per individual manufacturer’s design depending upon load, speed and drive. However, the pit depth and overhead shall be such as to confirm to the requirements of bottom clearance and top clearance of IS 14665 (Part 2/Sec 1). (vi) Contractor to obtain permission and approval prior to commencement of work and lift license from state govt authority. (vii) Item cost includes required scaffolding & structural steel brackets for erecting lift as per above specification, obtaining required all necessary permissions of Lift inspector to erect and complete the elevator work, Laisons to operate the elevators including all necessary charges,payments for the same etc complete. (viii) Contractor to verify all above required dimension at site prior to procurement of lift . In the event of any variation the commercially available standard size lift with respect to load and category shall be submit to dept for approval. (ix) Contractor shall submit GA drawing along with other relevant details to GE for approval prior to procurement of lift.
Supply, installation, testing and commissioning of LT panel indoor type floor mounted design verified confirming of IS/IEC 61439- 1 & 2, CPRI approved, totally enclosed vermin proof suitably ventilated, factory built, modular, sectionalised, compartmentalized, extendable type suitable for operation on 3 phase, 4 wire 433/415 Volts, 50Hz, AC supply.The outer sheel shall be fabricated out of 2.0mm thick CRCA sheet & MS angle section of suitable size for frame and compartmentalized inner shell shall be fabricated of out of 1.6 mm thick CRCA sheet for control gear. Front and back door operating with locking arrangement at front . The panel shall have vibration free structure with Protection of enclosure IP 55 as per IS-2147 of 1962 with pre-treatment trhough 7 tank hot chemical process prior to powder coated with minimum 50-70 micron of approved colour. The bottom of outer shell contains a detachable gland plates shall be fabricated out of 3mm thick CRCA sheet having provision for entry of armoured cable of adequate size complete with stiffeners wherever required. The bottom base channel of section not less than 100mmX 50mmX 5 mm thick, fabrication shall be done in transportable sections. The entire panel shall have a common earth bar of required size at the rear with 2 Nos. earth stud, connections and interconnection with solid conductor wires / copper strips, neutral links, control wiring with 1.5 sqmm. & 2.5sqmm.The panel shall be provided with manufacturer name plate,heavy duty SS cable glands of adequate size for incoming and outgoing cables.Computer cut self adhesive vinyl danger notice plate having conventional symbol of bones and skull to be provided.
Item No. 20.301 contd EPDM gasket of appropriate shape and size provided at all joints, door and covers including suitable size angle iron/flat iron frame work/support required with four legs 60cm long using angle iron 40x40x6mm duly painted with anti corrosive paint, air passing holes and locking arrangement at front with duplicate keys and making connection of incoming and outgoing cable using proper cable lugs, 4 x legs grouted in PCC 1:2:4 and making good distrubed surface complete including providing and fixing following switch gears and as per schedules and technical specifications etc.The panel shall be designed for suitable for Lift, complete as required and comprising of the following:- (A) (i) TPN Aluminium electrolytic grade high conductivity bus bar of rating not less than the 1.5 times the rated capacity of incomer MCCB shall be insulated with colour coded heat shrinkable sleeves and mounted on suitable size F class insulators made of non hygroscopic , non combustable, track resistant, high strength FRP/MC/DMC material at an interval not more than 500mm through out the length of busbar along with extension and interconnected busbar.The extension link shall not be less than 300mm long supported on suitable size F class insulators for termination of incoming and outgoing cables.All control wires shall be with 2.5sqmm FRLS multi stranded copper conductor and shall be properly bunched , tied,ferruled for proper identification and crimped with adequate size of lugs (ii) Digital multifunction meter (V,A,KW,KWH), 415 AC alongwith C.T's of suitable ratio (set of three), class 1.0, complete for metering (iii) Indication lamps LED type (RYB) =01 set of three .(iv) MCB SP 6A 'C' series for control ckt protection = 02Nos.
Item No. 20.301 contd (B).INCOMER (i)MCCB 200 Amp 4 pole, 36 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with adjutsable magnetic and adjustable thermal release, adjustable overload 65% to100% and adjustable short circuit release from 3.5 to10 ln setting complete with phase seperator - 02 Nos(01 nos working + 01 nos Stand by) (C). OUTGOING (i)MCCB 63 Amp 4 pole, 16 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator -04 Nos(03 nos working + 01 nos standby) (ii) MCCB 40 Amp 4 pole, 16 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator -04 Nos(03 nos working + 01 nos standby) (iii) MCCB 32 Amp 4 pole, 16 KA, lcs =100% lcu,confirming to IS:13947(Part-3) 1993 and IS/IEC:60947(Part-2) with fixed magnetic and adjustable thermal release, adjustable overload 70-100% and fixed short ckt release suitable for 10 ln setting complete with phase seperator -03 Nos(02 nos working + 01 nos standby) (iv) MCB SPN 10 KA 32 amp - 03 nos. Note :(i) LT panel shall be CPRI approved (ii) Contractor shall submit the following Test report i.e. IP Test Report and verification of short circuit withstand test report to GE (iii) Contractor shall submit GA drawing prior to procurement of LT Panel for approval of GE/CWE. (iv) The items mentioned in description are indicative only. Any item not specifically mentioned but required for reliable, safe and unattended trouble free operation shall be included in the scope of the contractor for which no additional payments shall be made
MGPS PLANT ROOM
S& F flame proof / weather proof ceiling fan 1200mm sweep operating voltage range of 150V to 265V ,270RPM, in aluminium die cast alloy LM6 construction ,recommended for gas/ vapor group of IIA & IIB Zone 1 & 2 ,certified by CSIR-CIMFR,BIS, and PESO, ISI marked complete all as directed.- 04 Nos ( Location : MGPS Plant room and Manifold Room)
S& F flame proof / weather proof exhaust fan 380mm sweep,0.25 HP operating voltage range of 150V to 265V ,in flame proof(Ex-d) enclosure for gas/ vapor group of IIA & IIB,IIC as per IS/IEC 60079-1:2014 , with weather prrof protection IP -65 as per IS /IEC 60529:2001(Reaffirmed 2014),Zone 1 & 2 & 21 & 22, certified by CSIR-CIMFR,BIS, and PESO, finished in epoxy powder coated shade as per IS:5, aluminium(non sparking) blade material, provision for earthing 1 Noterminal & 2 Nos external complete with Class F motor insulation , ISI marked complete all as directed.- 04 Nos ( Location : MGPS Plant room and Manifold Room)
Supply & fixing of Flameproof Ex"d", weather proof MCB Distribution Box , TPN 4 way, 430V,50Hz, CSIR-CIMFR certified recommended for gas/ vapor group of IIA & IIB, Zone 1 & 2 & 21 and IP 66 weather proof protection with Grey Epoxy Powder Coated Pressure Die Cast LM6 Aluminium Alloy Housing ,suitable for flush mounting or surface mounting, with suitable size of Busbar for each phase, Neutral Bar, Earth Bar and Cable ties for cable management, with Provision for MCCB as incomer and SP/TP MCB's Outgoing including dissmantling existing one with its accessories, cutting chases to wall for fixing DB and making good the disturbed wall surface complete all as required at site and as directed comprising of following items as under:- (a) Incomer - MCCB 4 Pole 40 A with Electronic Protection Unit Ics=100% Icu, Adjustable overload protection .4 to 1 x In, Protection against Short curcuit 1.5 to 10 Ir, inbuilt instatneous protection,complete all as directed and specified Qty - 01 Nos (b) Outgoing (i) MCB single pole 240 volts 10 Amps, C Curve, with rupturing capacity 10 KA ISI marked Biconnect lower terminals, IP 20 protected terminals, sliding shutters Qty -02 Nos (ii) MCB single pole 240 volts 16 Amps, C Curve, with rupturing capacity 10 KA ISI marked Biconnect lower terminals, IP 20 protected terminals, sliding shutters Qty -01 Nos (iii) MCB Tripple pole 415 volts 20 Amps, C Curve, with rupturing capacity 10 KA ISI marked Biconnect lower terminals, IP 20 protected terminals, sliding shutters Qty -02 Nos (iv) MCB Tripple pole 415 volts 25 Amps, C Curve, with rupturing capacity 10 KA ISI marked Biconnect lower terminals, IP 20 protected terminals, sliding shutte( Location : MGPS Plant room and Manifold Room)rs Qty -01 Nos
MGPS PIPELINE SYSTEM
OXYGEN GAS UNIT
Supply, Installation, Testing & Commissioning of Oxygen Manifold (2x10) comprising of (CE marked 4 digit) Oxygen Manifold (10+10) size suitable for bulk oxygen cylinders with 20 Nos. pig tail pipes & 20 Nos. of non return valves with middle frame complete suitable to with stand a pressure of 2400 PSI. The main frame are made out of 50 X 50 X 5 mm angle iron and bottom frame of 20 X 20 mm ms square Pipe are install in such a way that the cylinders must be stage for use in upright position and are not fell down under any circumstances. The gases passed through inter-connecting copper tail pipes duly fitted with suitable bull nose and nut adopter for cylinder valve and tube size should be 10 mm OD Copper tube duly annealed having wall thickness 1.5 mm in spiral shape and the other end of the tail pipe are fixed with non-return valve. The non return valve are fixed in brass block of size 25 mm square vertically fitted with high pressure copper tube of size 15mm OD having wall thickness 1.5 mm. Both the arms of manifold further fixed in automatic control panel. All the joints of copper tube, brass block, and inter connecting tubes are welded with silver brazing. The manifold is fabricated in such a way to give distribution flow of 2500 ltrs per minute(Maximum). The manifold Should be degreased and purged with inert gas before commissioning. The manifold Should be enamel painted as per color code complete all as specified and as directed by Engr-in-charge. Note: (i)The cylinders are not be included in the quoted price (ii) The complete manifold system should comply and fully meets with the latest standard and certificate to this effect issued by notified body shall be submitted.
Supply, Installation, Testing & Commissioning of 2 X 4 cylinders oxygen emergency manifold (CE marked 4 digit)/ Oxygen emergency point complete with 8 Nos. pig tail pipes & 8 Nos. of non return valves with middle frame complete in all aspect.The emergency system Should be consists of 4 + 4 cylinders - configuration suitable to withstand a pressure of 2400ps .This Should be inter connected with analog and digital automatic control panel which should be 2500 PM oxygen flow. Line pressure should not disturb in case of power failure. The changeover should take place via Pneumatic 5 no.s shuttle valves, each having capacity of 500 LPM. In case of failure of secondary line pressure regulator. The control panel can be operated manually with first stage regulator. The control panel should be fitted with bypass valve for enhanced safety. The bypass valve should be open automatically in case of pressure goes beyond 5 Bar. For tesing and calibraation purpose one outlet point should be integrated ( Emergency system utilized in case of emergency or during servicing of main manifold, the supply of medical oxygen Should be restored immediately with this system.) complete all as specified and as directed by Engr-in-charge. Note: (i)The cylinders shall not be included in the quoted price (ii) The complete manifold system should comply and fully meets with the latest standard and certificate to this effect issued by notified body shall be submitted.
Supply, Installation, Testing & Commissioning of Fully automatic oxygen control panel (CE marked 4 digit) 2500 LPM (Maximum). The control panel Should be supplied as a pre-tested and pressure tested self- contained unit. The control panel should be able to withstand working pressure 2400psi and test pressure 3500psi. (Test Certificate Required). Control Panel consist of MS powder coated box having 2 primary high pressure, high flow brass regulator, having safety and set pressure uptp 0-12 bar @ 2500 LPM, 2 no.s Secondary regulator made out of Aluminium die casting with flow rate of 2500lpm @ 28mm in/out size along with pressure gauage and set pressure 0-6 bar, with 5no. shuttle valves of size 8mm inner dia having 500LPM flow in each shuttle valve fixed on common copper/Aluminium header with high pressure 10 mm outer dia. PU tube along with Digital pressure Transmitter having Digital Display in green in case of Normal running and Red display in case of Variation in pressure along with green and red indicator and buzzer. Per minute at a pressure of 4 bar (60psi) constantly on either bank.The control panel can be operated manually with first stage regulator. The control panel should be fitted with bypass valve for enhanced safety. The bypass valve should be open automatically in case of pressure goes beyond 5.0 Bar. The shuttle valves should work simultaneusly for best perfomance.For tesing and calibraation purpose one outlet point should be integrated .The control panel shall have following features:- (a) Electric audio- visual and digital indicators for each bank status. (b)Electrically audio-visual and digital indicators at the time of auto changeover. (c ) Independent gauges and Pressure Transmitter (d)Auto change over from on line bank to reserve bank and vise versa. (e) In built low-pressure audiovisual alarm. (f) Uninterrupted suuply of gases even in the case of failure of power supply. (g) Pneumatic change over with pressure diffrential. (h) Bypass manual supply in case of failure of secondary regulator. (j) It should be consist of 5 No.s Pneumatic operated shuttle valves. Note: (i) The automatic control panel should comply and fully meets with the latest standard and certificate to this effect issued by notified body shall be submitted.
Supply, Installation, Testing & Commissioning of Oxygen Gas outlets/gas terminal unit (CE marked 4 digit), 100% made out of hard Polycarbonate material with pressure injection molding process with matching probe/adaptor complete in all aspect with Base Plate, Upper Plate & Holder.The main housing should be made out of 25 mm or above size brass casting with fine machinery. 12 mm dia medical grade 150 mm long copper tube should be fixed with housing. There should be Nilon/Teflon 'O' ring and stainless steel ball to act as NRV. The gas terminal unit should be capable of single hand working and must have online servicing facility. It should have double lock facility.The Prob/Adopter should be non-inter changeable for specific gas and box should be colour coded as per specific gas.The terminal unit shall have following features as under :- (a) Should be front insertion type. (b)Terminal unit Should have mechanism with check valve.(c)Allow single hand operation.(d) On first insertion of probe the probe shall sit in housing as standby position. At this stage there shall be no gas flow. (e) Only on pressing the probe second time, the gas supply Should start.(f) Should close automatically when connected apparatus is removed.(g) For allowing on line maintenance the terminal unit should be equipped with a check valve for all positive pressure gases for closing gas supply whenever the outlet point is opened.(h)The outlet Should be non interchangeable for specific gas and it Should accept only correct medical gas adopter/Probe.(j) It Should be color coded as per HTM 2022 & BSEN 7396 Part 1 (2007).(k)The design of this outlet Should be compatible to installed vertical on valve horizontally on ICCU panel and area servicing unit and also vertical to fit in pendants. Note: (i)Terminal unit shall be supply with correct probe/ adopter. (ii) The complete manifold system should comply and fully meets with the latest standard and certificate to this effect issued by notified body shall be submitted.
Supply, Installation, Testing & Commissioning of BPC single type Pipeline Flow Meter (4 Digit CE Marked) and control knob Oxygen flow meter with Humidifier Bottle unit duly fitted with the fine adjustment valve. It Should be back pressure compensated to bear and control the Oxygen Pressure approx. 60psi. Flow meter unit Should be consisting of double wall rotameter has range of flow 0 to 15 ltrs. per minute with fine adjustment valve. The rota meter and humidifier bottle Should be made of clear, impact resistance polycarbonate (duly graduated). This unit Should be have attachment to fit humidifier bottle of capacity 100 Ml. consist of clear, impact resistance polycarbonate jar. The unit Should also have Screw on top for flow meter/plastic cap having nozzles for outlet tubes and the inlet tube end Should be multi function combination bubblier/ nebulizer to add the humidity and create an aerosol in Medical Gas. Min/Max mark shall be ,marked on the Bottle complete all as specified and as directed. Note: (i) The complete system should comply and fully meets with the latest standard and certificate to this effect issued by notified body shall be submitted.
NITROUS OXIDE UNIT :
Supply, Installation, Testing & Commissioning of 4 +4 Size of N20 manifold (CE marked 4 digit) complete with 04 Nos. pig tail pipes & 04 Nos. of non return valves with middle frame complete in all aspect. Note: (i) The cylinders are not be included in the quoted price (ii) The complete manifold system should comply and fully meets with the latest standard and certificate to this effect issued by notified body shall be submitted.
Supply, Installation, Testing & Commissioning of 2 X 2 cylinders Nitrous oxide emergency manifold (CE marked 4 digit) / N20 emergency point . The emergency system Should be consists of 2 + 2 cylinders - configuration suitable to withstand a pressure of 2400psi , inter connected with analog and digital automatic control panel which should be 2500 PM Nitrous oxide flow. Line pressure should not disturb in case of power failure. The changeover should take place via Pneumatic 5 no.s shuttle valves, Each having capacity of 500 LPM. In case of failure of secondary line pressure regulator. The control panel can be operated manually with first stage regulator. The control panel should be fitted with bypass valve for enhanced safety. The bypass valve should be open automatically in case of pressure goes beyond 5 Bar. The shuttle valves should work simultaneusly for best perfomance. For tesing and calibraation purpose one outlet point should be integrated. ( Emergency system utilized in case of emergency or during servicing of main manifold, the supply of medical oxygen Should be restored immediately with this system.) complete all as specified and as directed by Engr-in-charge. Note: (i)The cylinders shall not be included in the quoted price (ii) The complete manifold system should comply and fully meets with the latest standard and certificate to this effect issued by notified body shall be submitted.
Supply, Installation, Testing & Commissioning of Fully automatic N20 control panel (CE marked 4 digit) 2500 LPM (Maximum). The control panel Should be supplied as a pre-tested and pressure tested self- contained unit. The control panel should be able to withstand working pressure 2400psi and test pressure 3500psi. (Test Certificate Required). Control Panel consist of MS powder coated box having 2 primary high pressure, high flow brass regulator, having safety and set pressure uptp 0-12 bar @ 2500 LPM, 2 no.s Secondary regulator made out of Aluminium die casting with flow rate of 2500lpm @ 28mm in/out size along with pressure gauage and set pressure 0-6 bar, with 5no. shuttle valves of size 8mm inner dia having 500LPM flow with heater system in each shuttle valve fixed on common copper/Aluminium header with high pressure 10 mm outer dia. PU tube along with Digital pressure Transmitter having Digital Display in green in case of Normal running and Red display in case of Variation in pressure along with green and red indicator and buzzer. Per minute at a pressure of 4 bar (60psi) constantly on either bank.The control panel can be operated manually with first stage regulator. The control panel should be fitted with bypass valve for enhanced safety. The bypass valve should be open automatically in case of pressure goes beyond 5.0 Bar. The shuttle valves should work simultaneusly for best perfomance.For tesing and calibraation purpose one outlet point should be integrated .The control panel shall have following features:- (a) Electric audio- visual and digital indicators for each bank status. (b)Electrically audio-visual and digital indicators at the time of auto changeover. (c ) Independent gauges and Pressure Transmitter (d)Auto change over from on line bank to reserve bank and vise versa. (e) In built low-pressure audiovisual alarm. (f) Uninterrupted suuply of gases even in the case of failure of power supply. (g) Pneumatic change over with pressure diffrential. (h) Bypass manual supply in case of failure of secondary regulator. (j) It should be consist of 5 No.s Pneumatic operated shuttle valves. Note: (i) The automatic control panel should comply and fully meets with the latest standard and certificate to this effect issued by notified body shall be submitted
Supply, Installation, Testing & Commissioning of Nitrous oxide outlets/gas terminal unit (CE marked 4 digit), 100% made out of hard Polycarbonate material with pressure injection molding process with matching probe/adaptor complete in all aspect with Base Plate, Upper Plate & Holder.The main housing should be made out of 25 mm or above size brass casting with fine machinery. 12 mm dia medical grade 150 mm long copper tube should be fixed with housing. There should be Nilon/Teflon 'O' ring and stainless steel ball to act as NRV. The gas terminal unit should be capable of single hand working and must have online servicing facility. It should have double lock facility.The Prob/Adopter should be non-inter changeable for specific gas and box should be colour coded as per specific gas.The terminal unit shall have following features as under :- (a) Should be front insertion type. (b)Terminal unit Should have mechanism with check valve.(c)Allow single hand operation.(d) On first insertion of probe the probe shall sit in housing as standby position. At this stage there shall be no gas flow. (e) Only on pressing the probe second time, the gas supply Should start.(f) Should close automatically when connected apparatus is removed.(g) For allowing on line maintenance the terminal unit should be equipped with a check valve for all positive pressure gases for closing gas supply whenever the outlet point is opened.(h)The outlet Should be non interchangeable for specific gas and it Should accept only correct medical gas adopter/Probe.(j) It Should be color coded as per HTM 2022 & BSEN 7396 Part 1 (2007).(k)The design of this outlet Should be compatible to installed vertical on valve horizontally on ICCU panel and area servicing unit and also vertical to fit in pendants. Note: (i)Terminal unit shall be supply with correct probe/ adopter. (ii) The complete manifold system should comply and fully meets with the latest standard and certificate to this effect issued by notified body shall be submitted.
VACCUM CENTRAL SYSTEM (Duplex Medical Vacuum Base unit) :
Supply,Installation,design,testing and commissioning of Vaccum central system complete with vaccum pump , receiver tank and other allied accessories as under :- (a) Vaccum pump set with copper rotor suitable for operation on 3 phase 415 volts ,50 Hz AC supply, capacity 45 cfm per minute vacuum at 684mm (HG) with 2800 vaccum speed. The pump shall have CI body,and casing ring, single stage , oil sealed, rotary vane type,stationary, air-cooled, splash lubricated, base plate mounted confirming to IS specification or amended upto date .The pump shall be supplied with SS 410 Shaft and shaft sleeve , bronzeimpeller ,bronze bush and stamping lamination with high permeability steel for long life and increased efficiency,coupling guard, common base plate, foundation bolts, etc Pumps shall be provided with mechanical seal.Insulation: F class Protection: IP 55. Each pump shall have TEFC 1450 RPM three phase,415Volts electric motor duly controlled by star delta/DOL starter.The cap of motor in HP/KW shall be as per recommendation of the manufacturer complete all as specified and as directed by Engr-in-charge -02 nos ( 01 working + 01 standby) (b) Vaccum receiver tank -01 nos of 2000 LTR water capacity as per IS 225 and construction code as per IS 2825 with blast cap 300 psi including all accessories like vacuum gauge, drain valve,pressure Gauge ,Safety Valve , drain trap Inspection Window and other relevant accessories as required at site. (c ) Complete interconnected copper piping of size 12mm to 28 mm OD with BSP vertical non return valve of required size with vacuum gauge of required size of bottom connection with silencer and vacuums Bacteria filters and all other work to complete the vacuum system and as per the entire satisfaction of hospital authority
Supply, Installation, Testing & Commissioning of Vaccum gas terminal unit (CE marked 4 digit), 100% made out of hard Polycarbonate material with pressure injection molding process with matching probe/adaptor complete in all aspect with Base Plate, Upper Plate & Holder.The main housing should be made out of 25 mm or above size brass casting with fine machinery. 12 mm dia medical grade 150 mm long copper tube should be fixed with housing. There should be Nilon/Teflon 'O' ring and stainless steel ball to act as NRV. The gas terminal unit should be capable of single hand working and must have online servicing facility. It should have double lock facility.The Prob/Adopter should be non-inter changeable for specific gas and box should be colour coded as per specific gas.The terminal unit shall have following features as under :- (a) Should be front insertion type. (b)Terminal unit Should have mechanism with check valve.(c)Allow single hand operation.(d) On first insertion of probe the probe shall sit in housing as standby position. At this stage there shall be no gas flow. (e) Only on pressing the probe second time, the gas supply Should start.(f) Should close automatically when connected apparatus is removed.(g) For allowing on line maintenance the terminal unit should be equipped with a check valve for all positive pressure gases for closing gas supply whenever the outlet point is opened.(h)The outlet Should be non interchangeable for specific gas and it Should accept only correct medical gas adopter/Probe.(j) It Should be color coded as per HTM 2022 & BSEN 7396 Part 1 (2007).(k)The design of this outlet Should be compatible to installed vertical on valve horizontally on ICCU panel and area servicing unit and also vertical to fit in pendants. Note: (i)Terminal unit shall be supply with correct probe/ adopter. (ii) The complete manifold system should comply and fully meets with the latest standard and certificate to this effect issued by notified body shall be submitted.
Supply, Installation, Testing & Commissioning of ward vacuum unit vaccum regulator (4 Digit CE Marked) duly fitted with vacuum gauge to display flow rate and overflow safety trap.The unit shall have emergency on / off lever and fine adjustment valve for regulator. This system Should be supplied with pre fitted color coded gauge having dial size 50mm and vacuum 0 to 760 mm / hg including inter connected tubes, vaccum collection jar made out of Poly carbonate Clear material capacity 600ml duly graduated having autoclave properties upto 120 °C complete all as specified and as directed.
MEDICAL AND SURGICAL AIR PLANT(Duplex Medical Compressed Air Base UNIT 4 BAR & 7 BAR)
Supply,Installation,design,testing and commissioning of Medical air plant/ Duplex Medical Compressed air base unit suitable for 4.0 bar and 7.0 bar complete with following accessories as under :- (a) Compressed air system with air-cooled, Splash lubricated and baseplate mounted screw type compressor -02 nos, single stage,1440 rpm,duly coupled/belt driven with capacity to produce 50 cfm approximately free air delivery at working pressure of 90 psi and maximum pressure of 120 psi,belt driven,base plate mounted,air cooled and performance tested as per IS 5456.The compressor shall be fitted with 20 hp capacity induction electric motor three phase,415Volts of class F insulation,tested as per IS 325.The operation of motor shall be controlled by star delta/DOL starter including pre fitted slide rails. The compressor Should be installed duly fitted with suction filters. (b) Air receiver -02 nos, horizontal type of 2000 ltr water capacity as per IS 225 and construction code as per IS 2825 with blast cap 300 psi including all accessories like vacuum gauge, drain valve,pressure Gauge ,Safety Valve , drain trap Inspection Window and other relevant accessories as required at site. (c) Automatic twin chamber heatless air drier -02 nos , 50 cfm , 60 psi Should also be installed to dry compressed air at 90-psi pressure. Outlet dew point temperature Should be at 40° C and moisture contents at 100%RH (d) Filtration System: (2 Nos.) comprising of following filters :(i)Set of 4 no.s 50 CFM-01 set (ii) Charcoal Filter single-01 set Tower (iii) Fine Filter 0.03 micron -01 set duly fitted with pneumatic operated valve, set of filters, pre-filter, oil filter and pressure gauges to test the filter’s condition. (e) 2 No.s pressure reducing station for each compressor separately should be installed one for 4 bar and other for 7 Bar
Supply, Installation, Testing & Commissioning of Medical Air 4 Bar (MA-4) terminal unit (CE marked 4 digit), gas outlet point 100% made out of hard Polycarbonate material with pressure injection molding process with matching probe/adaptor complete in all aspect with Base Plate, Upper Plate & Holder.The main housing should be made out of 25 mm or above size brass casting with fine machinery. 12 mm dia medical grade 150 mm long copper tube should be fixed with housing. There should be Nilon/Teflon 'O' ring and stainless steel ball to act as NRV. The gas terminal unit should be capable of single hand working and must have online servicing facility. It should have double lock facility.The Prob/Adopter should be non-inter changeable for specific gas and box should be colour coded as per specific gas.The terminal unit shall have following features as under :- (a) Should be front insertion type. (b)Terminal unit Should have mechanism with check valve.(c)Allow single hand operation.(d) On first insertion of probe the probe shall sit in housing as standby position. At this stage there shall be no gas flow. (e) Only on pressing the probe second time, the gas supply Should start.(f) Should close automatically when connected apparatus is removed.(g) For allowing on line maintenance the terminal unit should be equipped with a check valve for all positive pressure gases for closing gas supply whenever the outlet point is opened.(h)The outlet Should be non interchangeable for specific gas and it Should accept only correct medical gas adopter/Probe.(j) It Should be color coded as per HTM 2022 & BSEN 7396 Part 1 (2007).(k)The design of this outlet Should be compatible to installed vertical on valve horizontally on ICCU panel and area servicing unit and also vertical to fit in pendants. Note: (i)Terminal unit shall be supply with correct probe/ adopter. (ii) The complete manifold system should comply and fully meets with the latest standard and certificate to this effect issued by notified body shall be submitted.
Supply, Installation, Testing & Commissioning of Surgical Air 7 Bar (SA-7) terminal unit (CE marked 4 digit), gas outlet point 100% made out of hard Polycarbonate material with pressure injection molding process with matching probe/adaptor complete in all aspect with Base Plate, Upper Plate & Holder.The main housing should be made out of 25 mm or above size brass casting with fine machinery. 12 mm dia medical grade 150 mm long copper tube should be fixed with housing. There should be Nilon/Teflon 'O' ring and stainless steel ball to act as NRV. The gas terminal unit should be capable of single hand working and must have online servicing facility. It should have double lock facility.The Prob/Adopter should be non-inter changeable for specific gas and box should be colour coded as per specific gas.The terminal unit shall have following features as under :- (a) Should be front insertion type. (b)Terminal unit Should have mechanism with check valve.(c)Allow single hand operation.(d) On first insertion of probe the probe shall sit in housing as standby position. At this stage there shall be no gas flow. (e) Only on pressing the probe second time, the gas supply Should start.(f) Should close automatically when connected apparatus is removed.(g) For allowing on line maintenance the terminal unit should be equipped with a check valve for all positive pressure gases for closing gas supply whenever the outlet point is opened.(h)The outlet Should be non interchangeable for specific gas and it Should accept only correct medical gas adopter/Probe.(j) It Should be color coded as per HTM 2022 & BSEN 7396 Part 1 (2007).(k)The design of this outlet Should be compatible to installed vertical on valve horizontally on ICCU panel and area servicing unit and also vertical to fit in pendants. Note: (i)Terminal unit shall be supply with correct probe/ adopter. (ii) The complete manifold system should comply and fully meets with the latest standard and certificate to this effect issued by notified body shall be submitted.
AGSS (ANAESTHESIA GAS SCAVENGING SYSTEMS)
Supply, Installation, Testing & Commissioning of Duplex AGSS Plant 1560 LPM capacity with one pump working and one standy, CE certified complies with BS 5864, BS 6832, HTM 2022, 93/42/ec. complete with CE certified AGSS terminal unit with probes fully complies with BS 6834 , htm 02-01. complete all as specified and as directed.
Supply, Installation, Testing & Commissioning of AGSS Hose assembly fully complies and meets with BS 6834, HTM 02-01 complete all as specified and as directed.
Supply, Installation, Testing & Commissioning of AGSS terminal unit (CE marked 4 digit), gas outlet point 100% made out of hard Polycarbonate material with pressure injection molding process with matching probe/adaptor complete in all aspect with Base Plate, Upper Plate & Holder.The main housing should be made out of 25 mm or above size brass casting with fine machinery. 12 mm dia medical grade 150 mm long copper tube should be fixed with housing. There should be Nilon/Teflon 'O' ring and stainless steel ball to act as NRV. The gas terminal unit should be capable of single hand working and must have online servicing facility. It should have double lock facility.The Prob/Adopter should be non-inter changeable for specific gas and box should be colour coded as per specific gas.The terminal unit shall have following features as under :- (a) Should be front insertion type. (b)Terminal unit Should have mechanism with check valve.(c)Allow single hand operation.(d) On first insertion of probe the probe shall sit in housing as standby position. At this stage there shall be no gas flow. (e) Only on pressing the probe second time, the gas supply Should start.(f) Should close automatically when connected apparatus is removed.(g) For allowing on line maintenance the terminal unit should be equipped with a check valve for all positive pressure gases for closing gas supply whenever the outlet point is opened.(h)The outlet Should be non interchangeable for specific gas and it Should accept only correct medical gas adopter/Probe.(j) It Should be color coded as per HTM 2022 & BSEN 7396 Part 1 (2007).(k)The design of this outlet Should be compatible to installed vertical on valve horizontally on ICCU panel and area servicing unit and also vertical to fit in pendants. Note: (i)Terminal unit shall be supply with correct probe/ adopter. (ii) The complete manifold system should comply and fully meets with the latest standard and certificate to this effect issued by notified body shall be submitted.
Supply, Installation, Testing & Commissioning of AGSS plastic Remote Indicator fully complies and meets with bs 6834, htm 02-01, CE marked complete all as specified and as directed.
Medical Grade Copper Tube/Pipes
Supply, Installation, Testing & Commissioning of Medical Grade Copper Tube/Pipes including all type of accessories Like,Tee, Elbow, Valves, etc. complete. The piped distribution system shall use copper pipes/tube soiled drawn seamless deoxidized manufactured from phosphorous de-oxidized non-arsenical copper grade CW024A (Cu-DHP), manufactured to metric outside diameters and having mechanical properties in accordance or in either R250 (half hard) or R290 (hard).Tempered and Degreasing of pipe as per BS EN 13348:2001 shall be such that there is less than 20mg/m2 (0.002mg/cm2) of hydrocarbons on the degreased surface when tested by the method specified Norms. all copper tube suppliers are to have BSI kite mark and certificate number.The contractor shall submit manufacturer test certificates for physical properties and chemical composition.he Tubes should be supplied with Third Party Test Certifications like LLOYD/TATA/SGS/CITCO every tube should have batch no. according to test Certificate. complete all as specified and as directed for the following sizes of copper tube/pipe :-
(a) Copper Pipes of 12mm OD x 0.7mm thick
(b) Copper Pipes of 15mm OD x 1.0mm thick
(c) Copper Pipes of 22mm OD x 1.0mm thick
(d) Copper Pipes of 28mm OD x 1.0mm thick
(e) Copper Pipes of 42mm OD x 1.20mm thick
Supply, Installation, Testing & Commissioning of isolation valves (CE Certified) ,class-I suitable for ambient temperature ,nickel-plated brass body having PTFE seat , inner outer seals and PTFE gaskets in between nuts and valve to prevent leakage.These valves Should have Working Pressure : 7.5 bar maximum and test pressure : 50 bar maximum. The valves shall be as per HTM 2022. with stainless steel ball of specific ID clearance so that line pressure Should not drop. All the nuts for fixing the ball valve Should be of brass with brass nozzles for easily brazing with copper tube. All ball valve assemblies Should be on approachable height for easily operation complete all as specified and as directed for the following sizes of valves :-
(a) 15mm OD
(b) 22mm OD
(c) 28mm OD
(d) 42mm OD
Supply, Installation, Testing & Commissioning of isolation Valves box assembly (4 Digit CE Marked) enclosure. This unit should be gas specific like for 2 gas unit, 3 gas unit & 4 gas unit.Each unit should be fixed in enclosed MS Powder coated box having visible front glass (breakable in case of emergency). The box should also have locking arrangement. complete all as specified and as directed for the following sizes of units :-
(a) 3Gas = 2 Gas+ 1VAC
(b) 5 Gas = 4 Gas+ 1VAC
(c) 6Gas = 5 Gas+ 1VAC
Supply, Installation, Testing & Commissioning of medical gas monitoring alarm system (CE marked),wall mounted , 50 flashes/min, capable of monitoring all the Medical Gases (Pressure & vaccum gases) suitable for operation on 240Volts AC input and 12 Volts DC output system with micro processor chip system. This alarm Should be of electromechanical technology to detect the fault, pressure sensors, which detect deviation from the normal operating limits, Should be installed. Each pressure Gas Should displayed by colored LEGEND'S to show normal and ‘Low’ conditions. At the time of receiving the fault the normal window/ indicator stop indication and other window Should blink and it also gives audio alarm. Unit shall comprising of alarm panel with test facility to check the internal circuits, mute facility for making silent the buzzer, acknowledgement facility for receiving the fault and reset facility for resetting the alarm after rectifying the fault complete all as specified and as directed for the following sizes of units :-
(a) 3Gas = 2 Gas+ 1VAC
(b) 5 Gas = 4 Gas+ 1VAC
Supply, Installation, Testing & Commissioning of modular medical Bed Head Unit (4 digit CE marked), 1200mm long, fabricated of aluminium1.6 mm thick sheet duly powder coated, along with side cover's of same color or white color. The panel should be pre fitted with 2 No.s 6/16 amp Socket, 2 No.s 6/16 amp switches, 1 no. dummy & cutouts for gas terminal unit as per requirement. Providing for Additional acessories on extra cost like I.V. Tree, Monitor Stand, Infusion Pump Stand & basket can also be provided complete all as specified and as directed.
Total amount of Schedule 'A' Part XX carried over to General Summary
SCH 'A' PART XXI (Outsourcing for manning & operation)
OUTSOURCE FOR AIR CONDITIONING
Outsourcing of services for manning and operation required for idle/warm up/test run of AC plant, Lifts and Fire Fighting pump during the period of taking over the hospital by users in general shift (1 shift per day) for performing the duties as directed by Engineer-in-charge for upkeep of AC plant, lifts and Fire Fighting Pump house complete.
Outsourcing for first year :- Outsourcing services for maintenance of AC plant of 3X150 TR capacity at Accidental & Emergency Department and Critical Care Operation Theatre Complex at 7 AF Hospital Kanpur Cantt by Refrigeration mechanic in 3 shift of 08 hours each daily having compressors with its connected items such as condensers/chillers,water lifting circulating pumps, Chilling pumps,Blower,Blower Motor,Cooling tower with fan and motor including connecting starters etc in all respect for smooth running of AC Plant during the running period to maintain designed Air Conditioning/chilled water temperature inside the building of operation theatre as directed by Engr-in-Charge for round the clock in three shift as :- 06:00 to 14:00 Hrs (I Shift) 14:00 to 22:00 Hrs (II Shift) 22:00 to 06:00 Hrs (III Shift) Note:- (i) Till final taking over of the hospital by user, idle/warm up/test run of AC plant shall be the responsibility of contractor and same shall be paid under item No. 21.01 above, commencement of regular manning and operation will be done after prior approval of GE. (ii) Log sheets will be supplied by contractor and prepaired and maintained daily. (iii) the plant will be run a round the clock in three shifts (i.e. one shift for 08 Hrs) (iv) The operator shall be one No. in each shift. (v) The operator shall be Minimum ITI passed with 3 years experience in the Trade of Ref Mech or equivalent trade. (vi) The responsibility to run the plant will be of contractor for 24 Hrs , in case any fault is occured in the plant, every efforts will be made by the contractor to repair it, In case plant remains close for want for repair for more than six hrs a penalty of Rs. 3000.00/- per hour will be charged from contractor. Remarks of JE E/M on log sheet will be final. (vii) Daily cleaning of all the equipments and sweeping of complete installation building inside and outside (surrounding) including its roofs & cutting of grass along with plant as mentioned and as all as directed by Engr-in-Charge. (viii) Contractor will display the following charts , posters in presentable conditions without any extra cost to the government:- (a) Operating instructions. (b) SOP (c) Standing Orders (d) Security Orders (e) Fire Orders (f) Bries description of E/M installations (g)Duty Rosters etc.
Item No. 21.02 contd (ix) Contractors will carry out routine maintenance of plant as recommended by manufacturer and MES norms and the charts will be maintained and displayed at installations. (x) UNIFORM/CLOTHING:- The duty staff/operator should be in proper uniform to be provided by contractor after getting approval of GE/EIC.
Outsourcing for Second year :- Outsourcing services for maintenance of AC plant of 3X150 TR capacity at Accidental & Emergency Department and Critical Care Operation Theatre Complex at 7 AF Hospital Kanpur Cantt by Refrigeration mechanic in 3 shift of 08 hours each daily having compressors with its connected items such as condensers/chillers,water lifting circulating pumps, Chilling pumps,Blower,Blower Motor,Cooling tower with fan and motor including connecting starters etc in all respect for smooth running of AC Plant during the running period to maintain designed Air Conditioning/chilled water temperature inside the building of operation theatre as directed by Engr-in-Charge for round the clock in three shift as :- 06:00 to 14:00 Hrs (I Shift) 14:00 to 22:00 Hrs (II Shift) 22:00 to 06:00 Hrs (III Shift) Note:- (i) Log sheets will be supplied by contractor and prepaired and maintained daily. (ii) the plant will be run a round the clock in three shifts (i.e. one shift for 08 Hrs) (iii) The operator shall be one No. in each shift. (iv) The operator shall be Minimum ITI passed with 3 years experience in the Trade of Ref Mech or equivalent trade. (v) The responsibility to run the plant will be of contractor for 24 Hrs , in case any fault is occured in the plant, every efforts will be made by the contractor to repair it, In case plant remains close for want for repair for more than six hrs a penalty of Rs. 3000.00/- per hour will be charged from contractor. Remarks of JE E/M on log sheet will be final. (vi) Daily cleaning of all the equipments and sweeping of complete installation building inside and outside (surrounding) including its roofs & cutting of grass along with plant as mentioned and as all as directed by Engr-in-Charge.
Item No. 21.03 contd (vii) Contractor will display the following charts , posters in presentable conditions without any extra cost to the government:- (a) Operating instructions. (b) SOP (c) Standing Orders (d) Security Orders (e) Fire Orders (f) Bries description of E/M installations (g)Duty Rosters etc. (viii) Contractors will carry out routine maintenance of plant as recommended by manufacturer and MES norms and the charts will be maintained and displayed at installations. (ix) UNIFORM/CLOTHING:- The duty staff/operator should be in proper uniform to be provided by contractor after getting approval of GE/EIC.
OUTSOURCING SERVICES FOR LIFT
Outsourcing Services for Lift (For first year):- Outsourcing services by OEM trained technician for Lift to attend/monitor breakdown and for preventive maintanance of entire system installed for Accidental & Emergency Department and Critical Care Operation Theatre complex at 7 AFH Hospital Kanpur cantt at each Lift (02 Nos of technician at passenger lift and 2 Nos technician at stretcher Lift) complete all as directed by Engineer-in-Charge for two shifts:- 06:00 tro 14:00 (I shift) 14:00 to 22:00 Hrs (II Shift) The technician shall be competent in the following field:- (a) trouible shooting, repairs and maintanance of lift control panels. (b) Uploading and downloading of ladder logic based programs. (c) Manual/Remote operation of lift and act as assistant for rescue in case of any failure of lift. (d) Technician shall be responsible for all short of periodical servicing required for the system like as cabin, doors control panel, drives, pilley,chain gear system, electric motor, sensors etc and maintain proper log sheets of the work carried out. NOTE:- (i) Till final taking over of the hospital by user, idle/warm up/test run of AC plant shall be the responsibility of contractor and same shall be paid under item No. 21.01 above, commencement of regular manning and operation will be done after prior approval of GE. (ii) Log sheets will be supplied by the contractor and prepared and maintaned daily. (iii) Shift duty will be only for Hospital working days. (iv) contractor shall provide required T&P for technician employed. (v) The Operator shall be ITI passed in a perticular field with 3 years experience. Any minor repair in the lift required will be carried out by the contractor with out any extra payment by the department. (vi) Daily cleaning of all the equipments and sweeping of complete inside and outside (surrounding) as mentioned and as all as directed by Engr-in-Charge.
Item No. 21.04 contd (vii) Contractor will display the following charts , posters in presentable conditions without any extra cost to the government:- (a) Operating instructions. (b) SOP (c) Standing Orders (d) Security Orders (e) Fire Orders (f) Bries description of E/M installations (g)Duty Rosters etc. (viii) Contractors will carry out routine maintenance of plant as recommended by manufacturer and MES norms and the charts will be maintained and displayed at installations. (ix) UNIFORM/CLOTHING:- The duty staff/operator should be in proper uniform to be provided by contractor after getting approval of GE/EIC.
Outsourcing Services for Lift (For first year):-Outsourcing services by trained technician to complete building for Lift at Night Shift (22:00 Hrs to 06:00 hrs) to attend/monitor breakdown and for preventive maintanance of entire system installed fo Accidental & Emergency Department and Critical Care Operation Theatre complex at 7 AFH Hospital Kanpur cantt for complete building for all Lifts complete all as directed by Engineer-in-Charge for third shifts as :- 22:00 Hrs to 06:00 Hrs (III Shift) The technician shall be competent in the following field:- (a) trouible shooting, repairs and maintanance of lift control panels. (b) Uploading and downloading of ladder logic based programs. (c) Manual/Remote operation of lift and act as assistant for rescue in case of any failure of lift. (d) Technician shall be responsible for all short of periodical servicing required for the system like as cabin, doors control panel, drives, pilley,chain gear system, electric motor, sensors etc and maintain proper log sheets of the work carried out. NOTE:- (i) Till final taking over of the hospital by user, idle/warm up/test run of AC plant shall be the responsibility of contractor and same shall be paid under item No. 21.01 above, commencement of regular manning and operation will be done after prior approval of GE. (ii) Log sheets will be supplied by the contractor and prepared and maintaned daily. (iii) Shift duty will be only for Hospital working days. (iv) contractor shall provide required T&P for technician employed. (v) The Operator shall be ITI passed in a perticular field with 3 years experience. Any minor repair in the lift required will be carried out by the contractor with out any extra payment by the department. (vi) Daily cleaning of all the equipments and sweeping of complete inside and outside (surrounding) as mentioned and as all as directed by Engr-in-Charge.
Item No. 21.05 contd (vii) Contractor will display the following charts , posters in presentable conditions without any extra cost to the government:- (a) Operating instructions. (b) SOP (c) Standing Orders (d) Security Orders (e) Fire Orders (f) Bries description of E/M installations (g)Duty Rosters etc. (viii) Contractors will carry out routine maintenance of plant as recommended by manufacturer and MES norms and the charts will be maintained and displayed at installations. (ix) UNIFORM/CLOTHING:- The duty staff/operator should be in proper uniform to be provided by contractor after getting approval of GE/EIC.
Outsourcing Services for Lift (For Second year):- Outsourcing services by OEM trained technician for Lift to attend/monitor breakdown and for preventive maintanance of entire system installed for Accidental & Emergency Department and Critical Care Operation Theatre complex at 7 AFH Hospital Kanpur cantt at each Lift (02 Nos of technician at passenger lift and 2 Nos technician at stretcher Lift) complete all as directed by Engineer-in-Charge for two shifts:- 06:00 tro 14:00 (I shift) 14:00 to 22:00 Hrs (II Shift) The technician shall be competent in the following field:- (a) trouible shooting, repairs and maintanance of lift control panels. (b) Uploading and downloading of ladder logic based programs. (c) Manual/Remote operation of lift and act as assistant for rescue in case of any failure of lift. (d) Technician shall be responsible for all short of periodical servicing required for the system like as cabin, doors control panel, drives, pilley,chain gear system, electric motor, sensors etc and maintain proper log sheets of the work carried out.
Item No. 21.06 contd NOTE:- (i) Log sheets will be supplied by the contractor and prepared and maintaned daily. (ii) Shift duty will be only for Hospital working days. (iii) contractor shall provide required T&P for technician employed. (iv) The Operator shall be ITI passed in a perticulat field with 3 years experience. Any minor repair in the lift required will be carried out by the contractor with out any extra payment by the department. (vi) Daily cleaning of all the equipments and sweeping of complete installation building inside and outside (surrounding) as mentioned and as all as directed by Engr-in-Charge. (vii) Contractor will display the following charts , posters in presentable conditions without any extra cost to the government:- (a) Operating instructions. (b) SOP (c) Standing Orders (d) Security Orders (e) Fire Orders (f) Bries description of E/M installations (g)Duty Rosters etc. (viii) Contractors will carry out routine maintenance of plant as recommended by manufacturer and MES norms and the charts will be maintained and displayed at installations. (ix) UNIFORM/CLOTHING:- The duty staff/operator should be in proper uniform to be provided by contractor after getting approval of GE/EIC.
Outsourcing Services for Lift (For Second year):-Outsourcing services by trained technician to complete building for Lift at Night Shift (22:00 Hrs to 06:00 hrs) to attend/monitor breakdown and for preventive maintanance of entire system installed fo Accidental & Emergency Department and Critical Care Operation Theatre complex at 7 AFH Hospital Kanpur cantt for complete building for all Lifts complete all as directed by Engineer-in-Charge for third shifts as :- 22:00 Hrs to 06:00 Hrs (III Shift) The technician shall be competent in the following field:- (a) trouible shooting, repairs and maintanance of lift control panels. (b) Uploading and downloading of ladder logic based programs. (c) Manual/Remote operation of lift and act as assistant for rescue in case of any failure of lift. (d) Technician shall be responsible for all short of periodical servicing required for the system like as cabin, doors control panel, drives, pilley,chain gear system, electric motor, sensors etc and maintain proper log sheets of the work carried out. NOTE:- (i) Log sheets will be supplied by the contractor and prepared and maintaned daily. (ii) Shift duty will be only for Hospital working days. (iii) contractor shall provide required T&P for technician employed. (iv) The Operator shall be ITI passed in a perticular field with 3 years experience. Any minor repair in the lift required will be carried out by the contractor with out any extra payment by the department. (v) Daily cleaning of all the equipments and sweeping of complete inside and outside (surrounding) as mentioned and as all as directed by Engr-in-Charge.
Item No. 21.07contd (vi) Contractor will display the following charts , posters in presentable conditions without any extra cost to the government:- (a) Operating instructions. (b) SOP (c) Standing Orders (d) Security Orders (e) Fire Orders (f) Bries description of E/M installations (g)Duty Rosters etc. (vii) Contractors will carry out routine maintenance of plant as recommended by manufacturer and MES norms and the charts will be maintained and displayed at installations. (viii) UNIFORM/CLOTHING:- The duty staff/operator should be in proper uniform to be provided by contractor after getting approval of GE/EIC.
OUTSORCE SERVICE FOR PUMP HOUSE
Outsource for pump house for First Year :-Outsourcing services for maintanance fo Pump House/Fire station for Accidental & Emergency Department and Critical Care Operation Theatre complex at 7 AFH Hospital Kanpur cantt for handling of pumps, opening/closing of valve for filling of UG sump, maintaining water supply time to time complete along with maintaining clorination level as per MES norms for smooth functioning of water supply/fire system complete all as directed by Engineer-in-Charge for round the clock in three shift as :- 06:00 to 14:00 Hrs (I Shift) 14:00 to 22:00 Hrs (II Shift) 22:00 Hrs to 06:00 Hrs (III Shift) NOTE:- (i)Till final taking over of the hospital by user, idle/warm up/test run of AC plant shall be the responsibility of contractor and same shall be paid under item No. 21.01 above, commencement of regular manning and operation will be done after prior approval of GE. (ii) Log sheets will be supplied by the contractor and prepared and maintaned daily and will be submitted at 1000 Hrs daily to MES rep. (iii) The plant will be run a round the clock in three shifts (i.e. one shift for 08 hrs) (iv) The operator shall be one no in each shift. (v) The Operator shall be ITI passed in a particular field with 3 years experience in the trade of Fitter or equivalent trade. (vi) The responsibility to run the plant will be of contractor for 24 Hrs , in case any fault is occured in the plant, every efforts will be made by the contractor to repair it, In case plant remains close for want for repair for more than six hrs a penalty of Rs. 3000.00/- per hour will be charged from contractor. Remarks of JE E/M on log sheet will be final. (vii) Daily cleaning of all the equipments and sweeping of complete installation building inside and outside (surrounding) including its roofs & cutting of grass along with plant as mentioned and as all as directed by Engr-in-Charge.
Item No. 21.08 contd (viii) Contractor will display the following charts , posters in presentable conditions without any extra cost to the government:- (a) Operating instructions. (b) SOP (c) Standing Orders (d) Security Orders (e) Fire Orders (f) Bries description of E/M installations (g)Duty Rosters etc. (ix) Contractors will carry out routine maintenance of plant as recommended by manufacturer and MES norms and the charts will be maintained and displayed at installations. (x) UNIFORM/CLOTHING:- The duty staff/operator should be in proper uniform to be provided by contractor after getting approval of GE/EIC.
Outsource for pump house for Second Year :-Outsourcing services for maintanance fo Pump House/Fire station for Accidental & Emergency Department and Critical Care Operation Theatre complex at 7 AFH Hospital Kanpur cantt for handling of pumps, opening/closing of valve for filling of UG sump, maintaining water supply time to time complete along with maintaining clorination level as per MES norms for smooth functioning of water supply/fire system complete all as directed by Engineer-in-Charge for round the clock in three shift as :- 06:00 to 14:00 Hrs (I Shift) 14:00 to 22:00 Hrs (II Shift) 22:00 Hrs to 06:00 Hrs (III Shift) NOTE:- (i) Log sheets will be supplied by the contractor and prepared and maintaned daily and will be submitted at 1000 Hrs daily to MES rep. (ii) The plant will be run a round the clock in three shifts (i.e. one shift for 08 hrs) (iii) The operator shall be one no in each shift. (iv) The Operator shall be ITI passed in a particular field with 3 years experience in the trade of Fitter or equivalent trade. (v) The responsibility to run the plant will be of contractor for 24 Hrs , in case any fault is occured in the plant, every efforts will be made by the contractor to repair it, In case plant remains close for want for repair for more than six hrs a penalty of Rs. 3000.00/- per hour will be charged from contractor. Remarks of JE E/M on log sheet will be final. (vi) Daily cleaning of all the equipments and sweeping of complete installation building inside and outside (surrounding) including its roofs & cutting of grass along with plant as mentioned and as all as directed by Engr-in-Charge.
Item No. 21.09 contd (vii) Contractor will display the following charts , posters in presentable conditions without any extra cost to the government:- (a) Operating instructions. (b) SOP (c) Standing Orders (d) Security Orders (e) Fire Orders (f) Bries description of E/M installations (g)Duty Rosters etc. (viii) Contractors will carry out routine maintenance of plant as recommended by manufacturer and MES norms and the charts will be maintained and displayed at installations. (ix) UNIFORM/CLOTHING:- The duty staff/operator should be in proper uniform to be provided by contractor after getting approval of GE/EIC.
Total amount of Schedule 'A' Part XXI carried over to General Summary
GENERAL SUMMARY
Lumpsum price worked out by the contractor for "BUILDINGS AND STRUCTURES" as listed in Sch ‘A' Part-I on Srl Page No.31(R)(R)
(a) Lumpsum price worked out by the contractor for "Srl ltem No. 1 of Sch ‘A' Part-I i.e. Design and Construction of Main Building including Ramps and Parking Shed"
(b) Lumpsum price worked out by the contractor for "Srl ltem No. 2 of Sch ‘A' Part-I i.e. Design and Construction of AC Plant Room"
(c) Lumpsum price worked out by the contractor for "Srl ltem No. 3 of Sch ‘A' Part-I i.e. Design and Construction of Substation Building"
(d) Lumpsum price worked out by the contractor for "Srl ltem No. 4 of Sch ‘A' Part-I i.e. Design and Construction of RCC UG Sum cum Pump House and MGPS Room"
Lumpsum price worked out by the contractor for “SITE CLEARRANCE, EXCAVATION AND EARTHWORK"as listed in Sch ‘A” Part II representing above / below the lumpsum price as inserted by MES for Sch ‘A’ Part II on Srl Page No.32
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY” as listed in Sch ‘A” Part III representing above/below the lumpsum price as inserted by MES for Sch ‘A’ part III on Srl Page No. 34
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION” as listed in Sch ‘A” Part IV representing above/below the lumpsum price as inserted by MES for Sch ‘A’ part IV on Srl Page No.46
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY” as listed in Sch ‘A” Part V representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part V on Srl Page No.50
Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIFICATION" as listed in Sch ‘A” Part VI representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part VI on Srl Page No.69
Lumpsum price worked out by the contractor for “ROAD/PATH/CULVERT"' as listed in Sch ‘A” Part VII representing above/below the lumpsum price of as inserted by MES for Sch ‘A’ Part VII on Srl Page No. 72
Lumpsum price worked out by the contractor for “ SEWAGE DISPOSAL” as listed in Sch ‘A” Part VIII representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part VIII on Srl Page No. 74
Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Sch ‘A” Part IX representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part IX on Srl Page No. 75
Lumpsum price worked out by the contractor for “'COMPOUND WALL/CHAIN LINK FENCING” as listed in Sch ‘A” Part X representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part X on Srl Page No. 77
Lumpsum price worked out by the contractor for "LIGHTENING PROTECTION ” as listed in Sch ‘A” Part XI representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part XI on Srl Page No. 79
Lumpsum price worked out by the contractor for “STAND BY POWER SUPPLY (DG SET) ”as listed in Sch ‘A” Part XII representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part XII on Srl Page No. 81
Lumpsum price worked out by the contractor for “FIRE ALARM /FIRE FIGHTING SYSTEM/FIRE HYDRANT AND PANEL PROTECTION ”as listed in Sch ‘A” Part XIII representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part XIII on Srl Page No. 99
Lumpsum price worked out by the contractor for “UPS” as listed in Sch ‘A” Part XIV representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part XIV on Srl Page No. 101
Lumpsum price worked out by the contractor for “AIR CONDITIONING”as listed in Sch ‘A” Part XV representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part XV on Srl Page No. 126(R)
Lumpsum price worked out by the contractor for “HOT WATER SUPPLY”as listed in Sch ‘A” Part XVI representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part XVI on Srl Page No. 130
Lumpsum price worked out by the contractor for “COOLING APPLIANCES”as listed in Sch ‘A” Part XVII representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part XVII on Srl Page No. 131
Lumpsum price worked out by the contractor for “LIFT”as listed in Sch ‘A” Part XVIII representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part XVIII on Srl Page No. 133
Lumpsum price worked out by the contractor for “DEMOLITION / DISMANTLING"as listed in Sch ‘A” Part XIX representing above/below the lumpsum price as inserted by MES for Sch ‘A’ Part XIX on Srl Page No. 135
Total amount of SCHEDULE 'A' PART XX (MISC B/R & E/M ITEMS) brought forwarded from Serial Page No. 253(R)(R)
Total amount of SCH 'A' PART XXI (Outsourcing for manning & operation) brought forwarded from Serial Page No. 261(R)(R)
Arun Deo Kumar (BID ID -3279475)
B D Raizada Projects Pvt Ltd (BID ID -3279734)
Rabina Enterprises Pvt Ltd (BID ID -3279550)
Varindera Constructions Limited (BID ID -3279039)
M M SHAWL Engineers and contractors pvt ltd (BID ID -3279221)
Agarwal Jagdish Construction Company Pvt. Ltd. (BID ID -3278952)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid