Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAdmitted-Finance 1 GANESH DARSHAN ADV SURVE MARG SANDHURST ROAD W MUMBAI 9 | MUMBAI | MAHARASHTRA | ₹1.2 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 Cr+₹3.7 L (3.00%)Admitted-Finance | ₹1.3 Cr+₹3.7 L (3.00%) | L2 | Admitted-Finance |
| 3 | L3₹1.4 Cr+₹15.3 L (12.4%)Admitted-Finance | ₹1.4 Cr+₹15.3 L (12.4%) | L3 | Admitted-Finance |
| 4 | L4₹1.4 Cr+₹15.5 L (12.5%)Admitted-Finance UNIT NO 117 IDEAL DEVAJI KESHAVAJI INDUSTRIAL ESTATE W T PATIL MARG CHEMBUR MUMBAI MAHARASHTRA 400071 | MUMBAI SUBURBAN | MAHARASHTRA | 400071 | ₹1.4 Cr+₹15.5 L (12.5%) | L4 | Admitted-Finance |
| Sl No | Description | Qty | Unit | SPEEDFROST SERVICES PVT LTD L1 | Aswathi Power Controls L4 | AEW ELECTRICAL PVT.LTD L3 | GROMOS INDIA L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Maintenance of Electrical system at DAE, convention centre buildings with deployment of man power as per TSS1 | 24 | Months | 4,30,000 ₹1,03,20,000 | 4,46,000 ₹1,07,04,000 | 4,00,000 ₹96,00,000 Lowest | 4,12,000 ₹98,88,000 |
| 2.00 | Preventive and Breakdown Maintenances of Philips Dynalite, Lighting channel Relay controller and Dimming Push button stations (1set x 8 times) as per TSS 2 | 8 | Times | 1,000 ₹8,000 Lowest | 20,000 ₹1,60,000 | 10,000 ₹80,000 | 20,000 ₹1,60,000 |
| 3.00 | Preventive and Breakdown Maintenances of Philips make power supply controller for Auditorium "A" stage lighting Dimming Push button stations as per TSS 3 | 8 | Times | 1,000 ₹8,000 Lowest | 20,000 ₹1,60,000 | 10,000 ₹80,000 | 20,000 ₹1,60,000 |
| 4.00 | C-10 test of VRLA Battery bank (12 volt, 28 AH,20 Nos.) for 10kVA UPS with arranging load banks at DAE,CC building (2sets x 2 Times) as per TSS 4 | 4 | Times | 10,000 ₹40,000 | 7,000 ₹28,000 | 3,000 ₹12,000 Lowest | 18,000 ₹72,000 |
| 5.00 | SITC of 415 volt, 3pole/4pole (63 Amp to 125 Amp) MCCB with accessories for AHU starter incomer as per TSS 5 | 5 | Nos. | 8,525 ₹42,625 | 2,500 ₹12,500 Lowest | 10,000 ₹50,000 | 6,106 ₹30,530 |
| 6.00 | SITC of 415 volt, 3pole (16 Amp to 40 Amp) MCCB with accessories for AHU starter incomer as per TSS 6 | 5 | Nos. | 7,500 ₹37,500 | 2,800 ₹14,000 Lowest | 7,000 ₹35,000 | 3,478 ₹17,390 |
| 7.00 | SITC of 415 volt, 4 pole (100 Amp to 160 Amp) MCCB with accessories for AC, PDB as per TSS 7 | 3 | Nos. | 15,000 ₹45,000 | 3,500 ₹10,500 Lowest | 15,000 ₹45,000 | 7,774 ₹23,322 |
| 8.00 | SITC of 415 volt, 25 Amps, AC3 duty power contactors with auxiliary blocks and accessories as per TSS 8 | 2 | Sets | 2,000 ₹4,000 | 2,500 ₹5,000 | 3,600 ₹7,200 | 1,091 ₹2,182 Lowest |
| 9.00 | SITC of 415 volt, 32 Amps, AC3 duty power contactors with auxiliary blocks and accessories as per TSS 9 | 2 | Sets | 2,500 ₹5,000 | 2,900 ₹5,800 | 5,000 ₹10,000 | 2,305 ₹4,610 Lowest |
| 10.00 | SITC of 415 volt, 40 Amps, AC3 duty power contactors with auxiliary blocks and accessories as per TSS 10 | 4 | Sets | 3,000 ₹12,000 Lowest | 3,200 ₹12,800 | 7,000 ₹28,000 | 3,630 ₹14,520 |
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
2 Mar 2023, 6:00 pmClosed
Chief Engineer and Head, TSD
Chief Engineer and Head, Technical Services Division, BARC, Trombay, Mumbai-400085
Maintenance of electrical system for D.A.E,Convention centre,BARC, Anushaktinagar, Mumbai -94
2023_BARC_740770_1
BARC/TSD/146/2022-23
Open Tender
Electrical Works
Item Rate
728 days
DAE convention centre, Anushaktinagar, Mumbai
Please refer tender documents
5 documents required · 5 mandatory
₹0
₹3.0 L
DAE convention centre
15 Mar 2023
16 Feb 2023
6 Mar 2023
16 Feb 2023
2 Mar 2023
16 Feb 2023
16 Feb 2023 - 28 Feb 2023
24 Feb 2023
Amount
Maintenance of Electrical system at DAE, convention centre buildings with deployment of man power as per TSS1
Preventive and Breakdown Maintenances of Philips Dynalite, Lighting channel Relay controller and Dimming Push button stations (1set x 8 times) as per TSS 2
Preventive and Breakdown Maintenances of Philips make power supply controller for Auditorium "A" stage lighting Dimming Push button stations as per TSS 3
C-10 test of VRLA Battery bank (12 volt, 28 AH,20 Nos.) for 10kVA UPS with arranging load banks at DAE,CC building (2sets x 2 Times) as per TSS 4
SITC of 415 volt, 3pole/4pole (63 Amp to 125 Amp) MCCB with accessories for AHU starter incomer as per TSS 5
SITC of 415 volt, 3pole (16 Amp to 40 Amp) MCCB with accessories for AHU starter incomer as per TSS 6
SITC of 415 volt, 4 pole (100 Amp to 160 Amp) MCCB with accessories for AC, PDB as per TSS 7
SITC of 415 volt, 25 Amps, AC3 duty power contactors with auxiliary blocks and accessories as per TSS 8
SITC of 415 volt, 32 Amps, AC3 duty power contactors with auxiliary blocks and accessories as per TSS 9
SITC of 415 volt, 40 Amps, AC3 duty power contactors with auxiliary blocks and accessories as per TSS 10
SITC of 415 volt, 50 Amps, AC3 duty power contactors with auxiliary blocks and accessories as per TSS 11
SITC of 415 volt, 63 Amps, AC3 duty power contactors with auxiliary blocks and accessories as per TSS 12
SITC of 415 volt Over load relay for 3phase,1.5 HP motor as per TSS13
SITC of 415 volt Over load relay for 3phase,7.5 HP motor as per TSS 14
SITC of 415 volt Over load relay for 3phase,10 HP to 15 HP motors as per TSS 15
SITC of 415 volt Over load relay 3phase 20HP to 25 HP motors as per TSS 16
SITC of 415 volt Over load relay for 3phase 40 HP motors as per TSS 17
SITC of Electronic timer for Star - delta starter as per TSS 18
SITC of "NO" & "NC" Add on block for contactors as per TSS19
SITC of heating coils for,230V, 2kW storage Geyser with gasket O rings as per TSS 20
SITC of thermostat (0-80) degree for 2kW storage Geyser with accessories as per TSS 21
SITC of 230Volt, 2kW, 25 Litter capacity storage Geyser as per TSS 22
SITC of indication lamp for storage Geyser as per TSS 23
SITC of 415 V, 40Amps, contactor for PDB at guest room as per TSS 24
SITC of 2pole,240V, 25 Amp to 40 Amps,30mA RCCB as per TSS 25
SITC of 2pole, 240V, 25Amp to 40 Amps,30mA, HPI type RCCB as per TSS 26
SITC of 4pole,415 Volt, 4 pole,32 Amp to 63Amp MCB as per TSS 27
SITC of 1Pole,250V, 6Amp to 20 Amp,10kA,C curve, MCB as per TSS 28
SITC of 2Pole,250V, 20Amp to 40 Amp,10kA,C curve MCB as per TSS 29
SITC of 3pin 16 Amp to 20 Amp Plug top as per TSS 30
SITC of 20 Amp,(2P+E) metal clad Socket with top as per TSS 31
SITC of Digital timer switches for outdoor lighting with box as per TSS 32
SITC of 6 Amp to 10 Amp, 1modular SP switch as per TSS 33
SITC of 16 / 20 Amp,1modular SP switch as per TSS 34
SITC of 6 Amp,5 pin, 2modular Socket as per TSS 35
SITC of 6 /16 Amp combined,3pin, 2modular Socket as per TSS 36
SITC of 120 watt, 2module step fan regulators for energy saving fans as per TSS 37
SITC of 10Amp modular bell push as per TSS 38
SITC of RJ 45 data outlet socket cat6,1 module as per TSS 39
SITC of cover plates with frame for (1 to 3) module box with accessories for concealed boxes as per TSS 40
SITC of cover plates with frame for (4 to 6) module with accessories for concealed boxes as per TSS 41
SITC of cover plates with frame for 8 module with accessories for concealed boxes as per TSS 42
SITC of surface mounting 6 modular Plastic Boxes with cover plates & frame as per TSS 43
SITC of surface 8 modular Plastic Boxes with cover plates & frame as per TSS 44
SITC of capacitors suitable for (40 watt to 120 watt) all types of fans as per TSS 45
SITC Of Fly killer Set as per TSS 46
SITC Of florescent (FSLBL T815 w), (2Nos.of Blue colour tube & its ballast, transformer set) - 1Set for Fly killer as per TSS 47
SITC of 1.5 square mm FRLSPVC insulated (R,Y,B,N,G) copper wire as per TSS 48
SITC of 2.5 square mm FRLSPVC insulated (R,Y,B,N,) copper wire as per TSS 49
SITC of 4 square mm FRLSPVC insulated (R,Y,B,N,) copperwire as per TSS 50
SITC of 10 square mm FRLSPVC insulated (R,Y,B,N,G) copper wire as per TSS 51
SITC of 3 Core, 2.5 sq.mm copper conductor TRS sheathed cable as per TSS 52
S&I of Powder coated MS boxes and enclosures as per TSS 53
S&I of LT Panel's door locks, hinges, keys with required rectification & modifications etc. as per TSS 54
SITC of digital MFM (95x95)mm indication meters with all associated accessories for 415 volt panel as per TSS 55
SITC of LT panel's Indication LED lamps as per TSS 56
SITC of sets of copper lugs for 16 sq.mm to 25 sq.mm copper/Al. cables as per TSS 57
S&I of spray painting for metallic surface as per TSS 58
S&I of paintaing with brush for metallic surface per TSS 59
SITC of End terminations of 1.1kV,4Core,upto 25 sq.mm copper, Aluminium cable as per TSS 60
SITC of End terminations of 1.1kV, 3.5 core, 50 sq. mm to 185 sq.mm Aluminium cable as per TSS 61
SITC of End terminations of 1.1kV, 3.5 Core, 240 sq.mm to 300 sq.mm Aluminium cable as per TSS 62
SITC of End terminations of 1.1kV, 3.5 Core, 400 sq.mm Aluminium cable as per TSS 63
SITC of 230volt,1200mm sweep, BLDC ceiling fans with regulators as per TSS 64
SITC of 230volt, (380 to 450) mm sweep, 1400rpm,(150 to 400) watt heavy duty metal body Exhaust fans as per TSS 65
SITC of (230 to 250)Volt,10Amp,1000watt,360 degree angle,IP21 Motion Detector as per TSS 66
SITC of LED (12 to 15) watt indoor commercial lighting fixtures as per TSS 67
SITC of Dimmable 1000watt and 600 watt Halogen lamps with accessories as per TSS 68
SITC of dimmable 42 watt,4pin type, CFL lamps with accessories as per TSS 69
SITC of choke for dimmable (2Nos.x 42 watt, CFL) fixtures with accessories as per TSS 70
SITC of 26 watt,4pin type, CFL lamps with accessories as per TSS 71
SITC of choke suitable for (2 x 26 watt) CFL fixtures with accessories as per TSS 72
SITC of 36 Watt Fluorescent lamp as per TSS 73
SITC of choke for 36 watt Fluorescent light fixture as per TSS 74
SITC of starter for 36 watt Fluorescent lamp as per TSS 75
SITC Of CFL, 4pin type 36 watt as per TSS 76
SITC Of choke suitable for (2 x 36 watt) CFL downlighter fixtures as per TSS 77
SITC Of CFL, 2pin, 11 watt as per TSS 78
SITC of Choke for 9watt,11 watt CFL fixtures as per TSS 79
SITC Of 18 watt, CFL 4pin and 2pin CFL as per TSS 80
SITC of (2xPLC/T18watt), (1xPLC,18watt) Electronic ballast for 4pin and 2pin type 18 watt CFL as per TSS 81
SITC of 23 watt, threaded head type, CFL lamps with accessories as per TSS 82
SITC of LED,22 watt, approx. 1150 mm long, indoor batten type fixtures with aluminium housing &integrated driver as per TSS 83
SITC of LED,10 watt, approx. 600mm long, indoor batten type with aluminium housing & integrated driver as per TSS 84
SITC of 80 watt, 8800 Lumens, LED Out door flood light fixtures with mounting accessories as per TSS 85
SITC of copper lugs, ferrules etc. for straight jointing, terminations of (6 to 10) sq. mm FRLS/PVC insulated copper wires as per TSS 86
SITC of Straight through Raychem jointing for 1.1kV, 4core, 3.5 core 10 sq. mm to 35 sq. mm cable as per TSS 87
SITC of Straight through Raychem jointing for 1.1kV, 3.5core 50 sq. mm to 150 sq. mm cable as per TSS 88
SITC of Straight through Raychem jointing for 1.1kV,3.5 Core 90 sq. mm to 400 sq. mm cable as per TSS 89
SITC Straight through Raychem jointing for 1.1kV 4 Core / 3.5 Core 10 sq. mm to 35 sq. mm cable as per TSS 90
Supply and installation of all type of lamp's base holder, starter holder etc. for all type of CFL,MHD, Halogen lamps lighting fixtures as per TSS 91
Supply and installation of round PVC junction box cover plates with accessories for surface conduits as per TSS 92
Supply and installation of Banking plates for Legrand DB as per TSS 93
Supply and installation of connecting rod with operating handles for 415 volt ,(16 to 125) Amp MCCB with all mounting accessories as per TSS 94
Supply and installation of Elmex cable insulator connectors for panel's cable allay. Suitable for 16 sq. mm to 95 sq. mm cables as per TSS 95
S&I of 5 mm thick polycarbonate / PVC sheet with accessories for fixing the (2 to 12) modular cover plates as per TSS 97
Only installation of Cable outer dia. size 20 mm to 80 mm as per TSS 98
Only installation Copper strips / wire with mounting accessories as per TSS 99
Only Installation of 2.5 sq. mm and 4 sq.mm FRLSPVC insulated copper wires,Cat6data cables etc. as per TSS 100
Only installation of PVC Casing & capping, Conduits, GI/PVC Flexible conduits etc. with supply of all mounting accessories as per TSS 101
Only Installation of SP modular switch, sockets,RJ-11,RJ45,fan regulators, Modular switch boxes, MCB,RCCB, choke, igniter, capacitors other electrical components for utilities as per TSS 102
Removal of all type of Lighting fixtures, fans etc. as per TSS 103
Removal of PVC casing capping, MS Conduits, Flexible conduits, PVC wires etc.as per TSS 104
Removal of all type of cables outer dia. up to 50mm as per TSS 105
Rewinding of all type of 1phase fan motors,curtain's motor etc. as per TSS106
GROMOS INDIA
AEW ELECTRICAL PVT.LTD
Aswathi Power Controls
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 6.12 MB
SCHEDULE-A_BARC_TSD_146_2022_23.pdf
Tender Documents • 0.11 MB
BOQ_778887.xls
BOQ • 0.27 MB
TECHNICAL_BID_BARC_TSD_146_2022_23.xls
Tender Documents • 0.19 MB
TechSpecification146.pdf
Tender Documents • 0.30 MB
Tenderdocument.pdf
Tender Documents • 1.49 MB
Proforma_of_schedules_BARC_TSD_146_2022_23.pdf
Tender Documents • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .