Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L1 | Accepted-AOC BEING L1 AND REASONABLE | |
| 2 | L2₹20.2 L+₹25,676 (1.29%)Rejected-AOC | L2 | Rejected-AOC NOT BEING L1 | |
| 3 | L3₹24.0 L+₹4.0 L (20.2%)Rejected-AOC | L3 | Rejected-AOC NOT BEING L1 | |
| 4 | L4₹24.1 L+₹4.2 L (20.9%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | L4 | Rejected-AOC NOT BEING L1 | |
| 5 | L5₹24.6 L+₹4.6 L (23.1%)Rejected-AOC | L5 | Rejected-AOC NOT BEING L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
23 Feb 2023, 6:00 pmClosed
GE EM RR HOSPITAL
GE EM RR HOSPITAL DELHI CANTT 10
REPAIR MAINT OF INTERNAL WIRING AND CONNECTED ACCESSORIES AT ADC STATIC WORKSHOP AND OTHER PLACES AT AHRR UNDER GE EM RR HOSPITAL DELHI CANTT 10
2023_MES_577188_1
GE/H-45/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE EM RR HOSPITAL DELHI CANTT 10
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE EM RR HOSPITAL
₹50,000
Yes
17 Mar 2023
25 Jan 2023
25 Feb 2023
25 Jan 2023
23 Feb 2023
9 Feb 2023
Amount
Taking down copper/aluminium point wiring (light, fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per condition separately) and making good disturbed surfaces of wall, floor etc complete all as specified and directed by Engr-in Charge.
M&L for point wiring with 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and replacement of modular metal flush box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point/exhaust point controlled by one, one way switch 06 Amps complete all as directed. Note - All accessories likes modular top cover plate/ hylum sheet cover plate with frame, Modular type Metal flush box, screws as applicable will be included in quoted rates.
All as per srl item No. 02 here in before but point wiring for one socket outet point 3 pin 5 amps on the same board.
All as per srl item No. 02 here in before but point wiring for one socket outet point 3 pin 5 amps on the independent board.
All as per srl item no. 02 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 3/5 pin 15 Amp power point on Independent board.
Material and labour for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in & including PVC surface casing and caping including 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including modular MS sunken box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point/exhaust point controlled by one, one way switch 06 Amps complete all as directed. Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws, as applicable will be included in quoted rates.
All as per srl item No. 06 here in before but point wiring for one socket outet point 3 pin 5 amps on the same board.
All as per srl item No. 06 here in before but point wiring for one socket outet point 3 pin 5 amps on the independent board.
All as per srl item No. 06 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for 3/5 pin 15 Amp power point.
Material and labour for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in existing conduit including 1.5 Sq mm (nominal area) FRLS, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including modular MS sunken box, modular white cover plate with frame, blanking plate etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for one light / bell point/exhaust point controlled by one, one way switch 06 Amps complete all as directed. Note - All accessories likes modular top cover plate/ hylum sheet cover plate, Metal flush box, screws, as applicable will be included in quoted rates.
All as per srl item No. 10 here in before but point wiring for one socket outet point 3 pin 5 amps on the same board.
All as per srl item No. 10 here in before but point wiring for one socket outet point 3 pin 5 amps on the independent board.
All as per srl item no. 10 here-in-before but with 2.5 sq mm FRLS copper wire with 1.5 Sqmm FRLS copper earth wire for 3/5 pin 15 Amp power point on Independent board.
Material and labour in replacement of Sub main wiring with 2 run of 4 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in and including cutting and chasing,and also PVC conduit suitable dia as per SSR part-I with medium grade including 4.0 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as specified and directed by Engr-in Charge. Note : 1. The two run of 4.0 Sqmm wire, one run of 4.0 Sqmm wire and 1 run of PVC conduit will be measured as one unit.
All as per srl item no. 14 here-in-before but with 2 run of 6.0 sq mm FRLS copper wire with 6.0 Sqmm FRLS copper cable as earth wire.
All as per srl item no. 14 here-in-before but with 2 run of 10.0 sq mm FRLS copper wire with 10.0 Sqmm FRLS copper cable as earth wire.
All as per srl item no. 14 here-in-before but with 4 run of 6.0 sq mm FRLS copper wire with 6.0 Sqmm FRLS copper cable as earth wire. Note:- 1. The Four run of 6.0 Sqmm wire, one run of 6.0 Sqmm wire and 1 run of PVC conduit will be measured as one unit.
All as per srl item no. 14 here-in-before but with 4 run of 10.0 sq mm FRLS copper wire with 10.0 Sqmm FRLS copper cable as earth wire. Note:- 1. The Four run of 10.0 Sqmm wire, one run of 10.0 Sqmm wire and 1 run of PVC conduit will be measured as one unit.
Supply & fixing of Modular switch 6 Amp, 1 way, 1 module size complete all as specified and directed by Engr-in Charge.
Supply and fixing of Modular switch 16 Amp, 1 way, 1 module size complete all as specified and directed by Engr-in Charge.
Supply and fixing of Modular socket 6 Amp, 3 pin, 2 module size complete all as specified and directed by Engr-in Charge.
Supply and fixing of Modular socket 6/16 Amp, 3 pin, 2 module size complete all as specified and directed by Engr-in Charge.
Supply and fixing of Modular Fan regulator step type, 100 watts, 1 Module size complete all as specified and directed by Engr-in Charge.
Supply and fixing of Modular Bell push switch 6A with indicator lamp, 1 Module size complete all as specified and directed by Engr-in Charge.
Supply and fixing of Ceiling rose, PVC polycarbonate body isolated body, 3 terminal, 240 volts, 5 Amps complete all as specified and directed by Engr-in Charge.
Supply and fixing in replacement of electric bell of DINGDONG type, 240 volts, single pole and making all necessary connections complete all as specified and directed by Engr-in Charge.
Supply and fixing in replacement of MCB protected modular AC/Geyser box 3 module complete with and including 6 pin socket 25 amps, plug top, modular cover plate, mini MCB SP 25 Amp capacity and PVC gang box etc, complete all as specified and directed by Engr-in Charge.
S&F in repair sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, with 200 Amps rated copper bus bar 12 Way and metal door with IP - 43 & IK 09 protection along with cable end box for DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed by Engr-in Charge.
All as per srl item no. 28 here-in-before but 8 way.
All as per srl item no. 28 here-in-before but 4 way.
All as per srl item No. 28 here in before but 415 V 4 Way TPN all as directed by Eng- in Charge
All as per srl item No. 28 here in before but 415 V 8 Way TPN all as directed by Eng- in Charge
All as per srl item No. 28 here in before but 415 V 4 Way VTPN all as directed by Eng- in Charge
S&F in repair MCB SPN, AC, 240 volts of 40-63 Amps capacity "B" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed by Engr-in Charge.
S&F in repair MCB, SP, AC, 240 volts of 6 to 32 Amps capacity "B" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete all as specified and directed by Engr-in Charge.
Supply and fixing in replacement of MCB TPN 63 Amps, 10 kA with over load and short circuit protection complete all as specified and directed by Engr-in Charge.
S&F in repairs MCCB 4 pole thermal magnetic type 125 Amps, 25 kA including all electric connection and testing commissioning complete all as specified and directed by Engr-in Charge.
Refixing of serviceable and good condition MCBs , any types 6 amps to 63 amps received from old DBs complete all as specified and directed by Engr-in Charge.
S&F in replacement tube light retrofit rod 20 watt (CW), 4 feet long with high efficient LEDs available in clear & milky diffuser, PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed by Engr-in-Charge.
S&F in replacement LED tube light fitting 20 watt (CW), 4 feet long in extruded aluminium batten with high efficient LEDs available in milky diffuser and PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed by Engr-in-Charge.
S&F in replacement tube light fitting 10 watt (CW), 2 feet long in extruded aluminium batten with high efficient LEDs available in clear & milky diffuser and PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed by Engr-in-Charge.
S&F in replacement of recessed mounting LED light fitting (flat panel) 2'x2' with high efficeint LEDs and Glare free and opal diffuser of 36 watt (CW) including fixing accessories likes strip clips, wedge brackets etc, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of surface mounting LED light fitting (flat panel) 2'x2' with high efficeint LEDs and Glare free and opal diffuser of 36 watt (CW) including fixing accessories likes strip clips, wedge brackets etc, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement comfort bed light fitting for patient bed for Hospitals in extruded aluminium housing with PMMA diffuser having system Wattage of 31 Watts having three lights and having personalised bidirectional up & down light for pleasant and smoothing light experience including 03 Nos switches for each light complete all as specified.
S&F in repairs Building security light with high efficient high power LED street light 30 watt with lens with pressure die cast aluminium housing and enclosed with toghened glass, PF>0.95 and Voltage rated 220V to 240V etc complete all as directed.
Supply and fix in replacement of service bracket for mounting on wall of the bldg using 32mm bore light grade GI pipe with fixing accessories likes as clamps, fastener, nuts, bolts etc complete all as specified and directed by Engr-in Charge.
S&F in repairs energy efficient wall/ceiling mounted LED bulk head light fitting 10 watt, PF>0.95 and Voltage rated 220V to 240V etc complete all as directed.
Supply and fix in replacement of fresh air fan PVC body single phase, 240 volts, upto 1200 RPM of 200mm sweep, copper winding complete all as specified and directed by Engr-in-Charge.
All as per sl item No. 48 but 250 mm Sweep.
M&L in replacement for earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground, earth pit not less than 2.25 Mtr deep and top edge of plate not less than 1.25 mtr below ground level and connected to GI earth lead wire 4 mm dia fixed by means of nuts bolts etc including light grade GI pipe 15 mm dia bore for protection of GI wire 4mm dia, connected to earth test point surrounded by packed alternative layers of charcoal and common salt 15 cm thick all around top and bottom complete all as shown in plate No 5 to the earthing test point all as specified and indicated including provn of PCC chamber 1:3:6 using 20mm graded stone aggregate, 50mm thick cover with RCC 1:2:4 type B-1 using 8 mm dia TMT bars @ 100 mm C/C both ways as in reinforcement, necessary excavation, earthwork, returning filling and testing on completion etc complete all as specified and directed by Engr-in Charge.
Supply and fix in repair Switch socket combination 6 amps, 2-in-1 with PVC box, 240 volts, 50 Hz complete all as specified and directed by Engr-in Charge.
Supply and fix in repair Switch socket combination 20 A & 10 A amps,shutter type with PVC box, 240 volts, 50 Hz complete all as specified and directed by Engr-in Charge.
S&F in replacement of recessed mounting LED light fitting (flat panel) 1'X1' with high efficeint LEDs and Glare free and opal diffuser of 18 watt (CW) including fixing accessories likes strip clips etc, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement of surface mounting LED light fitting (flat panel) 1'X1' with high efficeint LEDs and Glare free and opal diffuser of 18 watt (CW) including fixing accessories likes strip clips etc, PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement recess mounted LED light fitting 18 watt(CW/WW) slim round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips and PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement recess mounted LED light fitting 15 watt(CW/WW) slim round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips and PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement surface mounted LED light fitting 15 watt(CW/WW) slim round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips and PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement recessed mounted LED light fitting 6 watt(CW/WW) slim round down lighter with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips and PF>0.95 and Voltage rated 220V to 240V etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement surface mounted LED light fitting (flat panel) 1' x 4' in size of 36 watt(CW) with high efficient LEDs and glare free opal diffuser including fixing accessories likes strip clips, wedge brackets etc, PF>0.95 and Voltage rated 220V to 240V complete all as specified and directed by Engr-in-Charge.
Taking down unserviceable ceiling / exhaust / cabin / wall / air circulator / padestal fans of any type / make / capacity from various locations of AHRR complex by disconnecting the electrical connection and overhauling the same comprising of cleaning the fans to remove sticky dust with cloth or emery paper, oiling, greasing, including replacement of defective parts such as split pins, terminal block, rubber reel, PVC bush, body screws, MS stator shaft work, Machining of shaft & fan body for making housing etc, applying one coat of synthetic enemal paint match with existing surface (white/green/gray colour) after prepration of old surfaces, marks MES Nos & AGE E/M RRH using black colour on all types fans and refixing the same in position after repair and testing complete all as specified and directed by Engr-in-Charge. Note- 1. Any parts other than indicated in item shall be measured and paid seperately under respective items here-in-after as supply only, however labour charges for taking down and fixing of these parts (except item catered M&L ) are deemed to be included in quoted rates.
M&L for rewinding of ceiling fan mortor of 1200 to 1400mm dia sweep including cutting and removing the old defective/burnt winding wire, cleaning the core of the fan motor, rewinding the fan motor with and including super enameled copper winding wire of appropriate/same gauge using insulating materials, varnishing the core assembly, drying the winding for adequate period to remove the moisture content, strengthening the winding and re-assembling the core including testing to the speed and flow of the fans, complete all as specified and directed by Engr-in-Charge.
All as per srl item no 61 here-in-before but for Exhaust fan of 230 to 380 mm sweep size.
All as per srl item no 61 here-in-before but for Exhaust fan of 450 mm sweep size.
Supply only ball bearing suitable for ceiling / exhuast fan of any type / size / make, complete all as specified and directed by Engr-in-Charge.
Supply only capacitor of 2.5 mfd, 440V, 50 Hz suitable for ceiling / exhaust / cabin / air-circulator / Padestal fan of any type / make / size, complete all as specified and directed by Engr-in-Charge.
All as per srl item no 65 here-in-before but of 3.15/4 mfd capacity.
Supply only metallic fan blades (Set of 3 or 4 blade)) of existing pattern & colour scheme including screws suitable for ceiling fan of any make / model / sweep size, complete all as directed.
All as per srl item no 67 here-in-before but for Exhaust fan of upto 300-380 mm sweep size.
All as per srl item no 67 here-in-before but for Exhaust of 450 mm sweep size.
Supply only factory made ceiling fan down rod 0.3 m long, made out of heavy grade MS conduit of 19/20 mm outer dia, with hole at both ends for passing cable, cut at one end for fixing of fan, hole at other end for fixing fan clamp, duly painted with white synthetic enemel paint of 1st quality, complete all as specified and directed by Engr-in-Charge.
All as per srl item no 70 here-in-before but 0.9 m long complete all as specified and directed by Engr-in-Charge.
CHAUHAN ENTERPRISES
ACR ENTERPRISES
RUCHIKA ENGG.WORKS
S.R. Constructions
AMIT ENTERPRISES
MK Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .