Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H7₹258.66−₹40.4 L (13.5%)Accepted-AOC | ₹258.66−₹40.4 L (13.5%) Quoted ₹2.6 Cr | H7 | Accepted-AOC H7,Awarded |
| 2 | H1₹3.0 CrRejected-Finance | ₹3.0 Cr | H1 | Rejected-Finance H1 |
| 3 | H2₹2.9 Cr−₹4.7 L (1.58%)Rejected-Finance | ₹2.9 Cr−₹4.7 L (1.58%) | H2 | Rejected-Finance H2 |
| 4 | H3₹2.8 Cr−₹15.9 L (5.30%)Rejected-Finance | ₹2.8 Cr−₹15.9 L (5.30%) | H3 | Rejected-Finance H3 |
| 5 | H4₹2.8 Cr−₹17.5 L (5.84%)Rejected-Finance | ₹2.8 Cr−₹17.5 L (5.84%) | H4 | Rejected-Finance H4 |
Tender Value
₹3.2 Cr
EMD Value
₹6.4 L
Closing Date
17 Feb 2025, 6:00 pmClosed
Empowered Officer, SRRDA,PMGSY
Office of the Empowered Officer, SRRDA, PMGSY Cell Lower lachumiere, Meghalaya, Shillong - 7930001 0364-2506228/ [email protected]
Construction i/c MBT
2025_CEMEG_138798_1
MG06III0802B
Open Tender
Civil Works - Roads
Item Rate
730 days
Bahadurkatta
Please refer Tender documents.
6 documents required · 6 mandatory
₹4,000
₹6.4 L
Yes
Shillong
1 May 2025
27 Jan 2025
18 Feb 2025
27 Jan 2025
17 Feb 2025
27 Jan 2025
27 Jan 2025 - 17 Feb 2025
4 Feb 2025
Amount
Excavation for Structures
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. I. Ordinary soil (i) Upto 3 m depth
Bored cast-in-situ M35 grade R.C.C. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. (Pile diameter-1000 mm)
Pile load test on single vertical pile in accordance with IS:2911(Part-IV)
Pile integrity Testing
Cement concrete for reinforced concrete in pile cap complete as per drawing and Technical Specification D. RCC Grade M35
Levelling course for Pile cap
Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
Plain / reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 and 1204 For height upto 5 m IV. R.C.C. grade M 35
Supplying, fitting and placing HYSD bar reinforcement (Fe 415) in substructure complete as per drawings and technical specification Clauses 1002, 1005, 1010 & 1202
Supplying, fitting and fixing in position true to line and level POT-PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against stainless steel mating surface, completre assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2006 of MoRTH Specifications complete as per drawing and approved technical specifications.
Providing weep holes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification Clauses 614, 709, 1204.3.7
Backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification Clause 1204.3.8 I. Granular material
Furnishing and Placing Reinforced/Prestressed cement concrete in superstructure as per drawing and Technical Specification D. PSC Grade M-35 For cast-in-situ box girder, segmental construction and balanced cantilever, 35-55% of cost of concrete (p) Height upto 5m
Supplying, fitting, and placing HYSD bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
Providing and laying cement concrete wearing course M 30 grade including reinforcement complete as per drawing and technical specifications Clauses 800 and 1206.3
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3
Drainage spouts complete as per drawing and technical specifications Clause 1209
Strip Seal Expansion Joint (Providing and laying of a strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete as per approved drawings and standard specifications to be installed by the manufacturer/supplier or their authorised representative ensuring compliance to the manufacturer's instructions for installation.)
Providing and laying pitching on slopes laid over prepared filter media as per drawing and technical specifications Clause 1302 I. Stone/Boulder
Providing and laying filter material underneath pitching in slopes complete as per drawing and technical specifications Clause 1302
Providing and laying of boulder apron laid in wire crates with 4 mm dia GI wire conforming to IS:280 and IS:4826 in 100 mm x 100 mm mesh (woven diagonally) including 10 per cent extra for laps and joints laid with stone boulders weighing not less than 25 kg each as per drawing and technical specifications Clause 1301
Construction of Embankment with Material Obtained from Borrow Pits Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5
Construction of Subgrade and Earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 with lead upto 1000 m as per Technical Specification Clause 303.1.
Granular Sub-base with Well Graded Material (Table 400.1) (A) Construction of granular sub-base with locally available graded material, spreading in uniform layers with motor grader on prepared surface, watering to OMC and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification/ direction of EE. (II) For Grading II Material
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, laying in uniform layers in sub-base/base course on a well prepared sub-base and compacting with smooth wheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406.
Low porosity Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502
Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared dry and hungry bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.
Bituminous Concrete (Providing and laying bituminous concrete with 100-120 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 to 5.6 % of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 509 complete in all respects)
Good and Service Tax (18%)
M/S. Upendra Nath Saha (BID ID -607700)
Saiyeed Murtaza Hossain (BID ID -608023)
A R CONSTRUCTION (BID ID -607795)
P. K. & COMPANY (BID ID -607882)
M/S M.P. AGARWAL PVT LTD (BID ID -608034)
J.S. and Company (BID ID -607746)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
BOQ.xls
BOQ • 0.30 MB
Tenderdocument.pdf
Tender Documents • 2.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .