| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC | L1 | Accepted-AOC Being lowest tender | |
| 2 | L2₹13.6 L+₹14,400 (1.07%)Rejected-Finance HOSUE NO 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 MP | GWALIOR | MADHYA PRADESH | 474005 | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹13.9 L+₹44,070 (3.27%)Rejected-Finance 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹14.1 L+₹67,060 (4.98%)Rejected-Finance 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L4 | Rejected-Finance Not being lowest tender | |
| 5 | L5₹14.9 L+₹1.4 L (10.5%)Rejected-Finance | L5 | Rejected-Finance Not being lowest tender |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
29 Jun 2024, 6:00 pmClosed
GE (AF) ADM AREA
GE (AF) ADM AREA GWALIOR
REPAIR /REPLACEMENT OF LT PANEL BOARDS AND ALLIED WORKS AT AIR FORCE STATION GWALIOR
2024_MES_658531_1
8424/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
GE (AF) ADM AREA GWALIOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) ADM AREA
₹40,000
Yes
3 Sept 2024
8 Jun 2024
6 Jul 2024
8 Jun 2024
29 Jun 2024
22 Jun 2024
Amount
All as per Item No 2.00 here-in-before but Ammeter of upto (0- 800) amps capacity.
S&F in replacement of current transformers of ratio 100/5 to 400/5 Amps in existing LT feeder piller panel and making connections of secondary terminals to ammeter with using 1.5 Sqmm PVC insulated and sheathed copper conductor cable including, testing and commissioning complete all as specified and directed by Engineer-in-Charge
All as per Item No 4.00 here-in-before but current transformers of 500/5 to 800/5 amps ratio.
S&F in replacement of indication lamps LED type with showing red, yellow and green colours of 22.5mm dia fixed to monitor on LT panel board suitable for 240 Volts AC supply and making connections with using 1.5 Sqmm PVC insulated and sheathed copper conductor cable including, testing and commissioning complete all as specified and directed by Engineer-in-Charge.
Dismantling, taking out of serviceable bus bar of any size and capacity in any position for re-use from the dismantled/taken down feeder pillar box/panel board all as directed.
Dismantling, taking out/removing serviceable and functional, fittings/fixtures/ accessories like MCCB/change over switch/switch fuses unit etc. of any description & in any position for re-use from the dismantled/taken down feeder pillar box/panel board all as directed.
Fixing only including necessary connection and commissioning of the following fittings / fixtures/accessories in the existing or newly fabricated panel board/feeder pillar box all as specified and directed by Engineer-in-Charge.
(a) Aluminium bus bars of any shape and size .
(b) MCCB/change over switch/switch fuses unit etc of any description, and current rating upto 400 Amps. (Note : Old serviceable retrieved / taken out / removed fittings etc. from the existing /taken down feeder pillar box / panel board shall be re-used in the work).
Supply and Fixing new Aluminium bus bars of any shape and size suitable upto 400 amp as directed by Engineer-in- Charge.
S&F in replacement of Porcelain Bus bar insulator in existing LT feeder piller boards including nuts, bolts and washers complete all as specified and directed.
Supply and fixing in repair mild steel sliding door assembly 200 mm size clip & bolt type, stove enameled black, with bright bolt not less than 12mm dia with and including welding the sliding bolt & staple plate including nut, bolts and washers in existing LT feeder pillar boxes complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MS Hinge plate in existing feeder piller boxes/ panel boards with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 2 mm thick CRCA sheet duly febricated in existing shape and size with and includingand all jointing material such as nuts bolts or washer and welding etc. complete all as specified and directed. NOTE : (i). The panel board repaired shall be made totally enclosed, weather proof, wermin proof for installing incoming / outgoing MCCB / Switch fuses/ cable etc. complete all as directed (ii) The rates quoted by the contractor are deemed to be included necessary cutting, welding, leveling and jointing etc. as directed to match & accommodate with the existing feeder pillar box / panel board . (iii) The replaced portion shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer.
M&L for preparation of the old decorated existing external and internal steel surfaces of feeder pillar boxes/panels/ boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopping as required and applying two coats of synthetic enameled paint (grey in color) with using spray machine on old prepared surfaces complete all as specified and directed .
Excavation in trenches in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 mtr wide and getting out including forming bottom surface to required levels/gradients/slopes for foundations/laying of cable etc. all as specified and directed including taking out existing cable protection brick cover etc.
Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed
Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed
M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge
Laying only servicable Sub Class `B’ bricks, old size, kiln burnt, laid with axis of brick perpendicular to the axis of the cable, for protection of cable all as specified and directed by Engr-in-Charge.
Supplying & Laying Sub Class `B’ bricks, old size, kiln burnt, laid with axis of brick perpendicular to the axis of the cable, for protection of cable all as specified and directed by Engr-in-Charge.
Disconnecting, taking out and removing old existing unserviceable underground, LT cable of any description and in any position complete including taking down unserviceable protection pipe, earth work to take out the loop where required etc, stacking the cables properly for reuse, the quoted rates shall be deemed to include cutting out the defective portion of cables and its removal from site all as specified and directed by the Engineer-in-Charge for the following sizes from ducts/ trenches / poles /pipes etc :-
(a) LT aluminium conductor cable of size upto 50 Sqmm, 3 ½ core
(b) LT aluminium conductor cable of size upto 70 Sqmm, 3 ½ core
(c) LT aluminium conductor cable of size over 95 Sqmm, 3 ½ core
(d) LT aluminium conductor cable of size over 120 Sqmm , 3 ½ core.
(e) LT aluminium conductor cable of size over 185 Sqmm, 3 ½ core
(f) LT aluminium conductor cable of size over 240 Sqmm, 3 ½ core
Laying, jointing and testing XLPE / PVC LT Cable PVC insulated, armoured, heavy duty electric cable with aluminum conductor 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-charge for the following sizes :- (cable obtained from item No 25.00 shall be used).
(a) LT aluminium conductor cable of size upto 50 Sqmm, 3 ½ core
(b) LT aluminium conductor cable of size upto 70 Sqmm, 3 ½ core
(c) LT aluminium conductor cable of size over 95 Sqmm, 3 ½ core
(d) LT aluminium conductor cable of size over 120 Sqmm , 3 ½ core.
(e) LT aluminium conductor cable of size over 185 Sqmm, 3 ½ core
M&L for jointing, testing sttraight though joints, heat shrinkable, suitable for XLPE LT UG cable 1100 volts for following sizes complete all as specified and directed.
(a) 25 sqmm to 50 sqmm 3 ½ core
(b) 70 sqmm to 120 sqmm 3 ½ core
(c) 150 sqmm to 185 sqmm 3 ½ core
(d) 240 sqmm to 300 sqmm 3 ½ core
M&L for surface excavation over the areas around the poles/feeder piller boxes/ Panels/ sub stations not exceeding 15 cm depth including cleaning the bushes and vegetation and leveling incl removal of surplus soil in hard/ dense soil. Note:- All necessary T&P and safety equipments required for the job will be provided by the contractor.
Supply, fabrication and fixing for mild steel structure such as cross arms, bracing, supports, clamps and back plate fabricated from structural steel sections including nuts & bolts, washers of any description on LT over head line poles/ street light poles including taking down existing steel structure complete all as specified & directed by Engineer -in- Charge.
Disconnecting existing LT over heated or burnt cable terminal at existing panel/ board/feeder pillar box etc., cutting out over heated / burnt / unserviceable and portion of cable, stretching / prepairetion of cable end of required length from available rings etc. and fixing and connecting the cable in position properly by providing suitable aluminium lugs and GI nuts, bolts & washers etc. all as directed by the Engineer-in-Charge for the following sizes of cable including neccessary excavation and earth work required to the Job.
(a) 25 Sqmm to 95 Sqmm cable of any core
(b) 120 Sqmm to 185 Sqmm cable of any core
(c) 240 Sqmm to 400 Sqmm cable of any core
Disconnecting & taking down old existing unserviceable MCCB of any description and in any position complete all as specified and directed by Engineer-in-Charge.
Supply, fixing, testing and commissioning MCCB, 630 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 35/36 KA with thermal setting 70% to 100% adjustable setting compelete all as specified and directed.
Supply, fixing, testing and commissioning MCCB, 400 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 35/36 KA with adjustable load setting compelete all as specified and directed.
Supply, fixing, testing and commissioning MCCB, 350 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 35/36 KA with adjustable load setting compelete all as specified and directed.
Supply, fixing, testing and commissioning MCCB, 250 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 35/36 KA with adjustable load setting compelete all as specified and directed.
Supply, fixing, testing and commissioning MCCB, 200 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 35/36 KA with adjustable load setting compelete all as specified and directed.
Supply, fixing, testing and commissioning MCCB, 160 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 35/36 KA with adjustable load setting compelete all as specified and directed.
Supply, fixing, testing and commissioning MCCB, 125 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity Icu = 16 KA with adjustable load setting compelete all as specified and directed.
Supply, fixing, testing and commissioning MCCB, 100 Amps, 3 pole, 415 Volts, AC supply, having breaking capacity Icu = 16 KA with adjustable load setting compelete all as specified and directed.
Disconnecting / Dismantling taking out old Spreader Terminals and Supply & Fixing new Spreader MCCB Terminals Current Rating 75/100/125 Amps all as specified and direcetd.
Disconnecting / Dismantling Taking out old Spreader Terminals and Supply & Fixing new Spreader MCCB Terminals Current Rating 150/175/200/250 Amps all as specified and direcetd.
Disconnecting / Dismantling Taking out old Spreader Terminals and Supply & Fixing new Spreader MCCB Terminals Current Rating 500/630/700/800 all as specified and direcetd.
Material and labour for earthing complete with Galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically earth pit not less than 2.25 meter deep below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI earth strip of size 25x4 mm as earthing lead by means of bolts, nuts and washers all as shown in electrical plate No 3 of MES Scedule part I (2009) with conected to eath test point including adequate quantity of charcoal dust and commen salt. PCC (1: 3 : 6) type C-1 chamber and for earth pit with 40x40x6mm mild steel angle iron frame for cover. precast RCC cover 40mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bars both ways with MS handle 12 mm dia. PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering and 40mm dia light earth lead protection pipe complete all as specified and directed. Note: Protection pipe and earth lead upto 7.5m is deemed to be included in quoted rates.
Supplying and fixing in repairs earth continuity conductor or main earthing lead 32mm x 6mm, GI strip/earth lead, laid in pipe/fixed on walls or any other position including jointing by tinned copper/brass nuts, bolts and washers and saddling, welding at every joint complete all as specified & directed.
Disconnecting & taking out non functional ACB (Air circuit breaker)of any description and any make of rating 11 KV, 400 Amps to 1000 Amps dismantling/opening of the ACB for servicing/over hauling taking out and removing unserviceable/defective parts including cleaning and servicing greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the ACB after over hauling /servicing and its testing complete all as specified and directed Note: - The quoted rates of the contractor includes for replacement of unserviceable parts with new parts. The new parts shall be measured and paid for separately under appropriate item of Sch 'A' as supply only
Supply only following spare parts for 11 KV ACB 400 to 1000 Amps capacity conforming to the respective cat part given as under : Note (i) fixing and testing element of following item is deemed to be included under item No 47.00 here-in-before quoted rate. The item shall be of existing make and description of replaced item.
(a) Arc Chutes for LT air circuit breakers
(b) Arcing Contacts (Set of 1 No. Fixed 1No. Moving ) for LT ACB
(c) Vertical Terminal Adapter for AH/AHA Fixed type ACB of 630/800 amps ACB
(d) Auxiliary Isolating contacts Blocks Assembly (set of one contact block on ACB side & two blocks on cradele side for 630/800 Amp ACB
(e) Single Phase Resin Cast CTS for " AA/AHA" ACB for Thermal release for LT air circuit breakers of 630/800 Amp.
(f) Auxiliary Isolating Contact Assembly (Set of one contact block on ACB side & two blocks on cradle side)for LT air circuit breakers .
(g) Auxiliary Isolating Contact Assembly (Set of one contact block on ACB side & four blocks on cradle side)for LT air circuit breakers.
(h) Main Isolating Contacts (Jaw Contacts) for LT air circuit breakers
(j) Lower terminals with fitting plates .
(k) Main Fixed Contacts (Upper Terminals) for LT air circuit breakers
Disconnectiong / Dismantling and Taking Out Old Earthing strip any type and any size from point of equipment, making the strip straight , removing all bends, Removal of deshaped portion and making the strip straight and in proper shape, Relaying the same in ground, on floor, wall etc with proper saddling/ Clampning and connecting with equipment and with necessary welding , Nut-bolts washers (Tinned copper) at all joints all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones signal in red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size all as per directed by Engineer-in-Charge.
Demolition of existing PCC platform of Transformer Sub Station of any capacity and M& L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate, repairing the cable duct after disconnecting the LT/HT cable from transformer to LT panel and relaying the same after repair of duct and laying the existing GI plate for covering of cable tray complete all as specified dircetd by Engr-in-Charge.
KP ELECTRICAL AND AUTOMATION
AUTOMATION AND SWITCHGEAR PANELS
M/s Anupam Construction Co.
m/s varsha traders
Kumar Sales Corporation
SHOURYA ENGINEERING ENTERPRISES
M/S KAPIL CONSTRUCTION CO
Achal Construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .