Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 LAccepted-AOC BORBARUAH BAZAR A T ROAD DIBRUGARH ASSAM | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹33.8 L+₹2.1 L (6.47%)Rejected-Finance GANDHI PARK ROAD TINSUKIA ASSAM PIN 786125 | TINSUKIA | ASSAM | 786125 | L2 | Rejected-Finance L2 | |
| 3 | L3₹34.7 L+₹3.0 L (9.35%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | L4₹35.0 L+₹3.3 L (10.3%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹36.5 L+₹4.8 L (15.0%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹29.9 L
EMD Value
₹59,800
Closing Date
20 Apr 2021, 6:00 pmClosed
GE DINJAN
GE DINJAN, PANITOLA (PO), DIBRUGARH (DIST), ASSAM
PROVN OF TOILETS AND BATHROOMS NEAR BLDG NO T-15, 01 x BULK STORE ROOM AND SPL REPAIR/REPLACEMENT OF HARD STANDING TFF, ATF BOWSER AND DRAIN DISPERSAL AREA (APPROX 100M) AT DINJAN MIL STN UNDER GE DINJAN
2021_MES_433651_1
C/8269/E8
Open Tender
Civil Works
Item Rate
180 days
DINJAN MIL STN
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
GE DINJAN
₹59,800
Yes
17 May 2021
30 Mar 2021
22 Apr 2021
30 Mar 2021
20 Apr 2021
14 Apr 2021
Amount
Surface excavation not exceeding 30 cm and averaging 15 cm and getting out in any type of soil complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removing surplus excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for PCC (1:4:8) type D-2 (Using 40mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed.
M&L for 100mm thick PCC (1:4:8) type D-2 (Using 40mm graded stone aggregate) as in sub base complete all as specified and as directed.
Demolition of cement concrete (unreinforced) exceeding 15 cm thickness above ground floor complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description and in any position not other wise specifically provided for complete all as specified and as directed.
Demolition of bricks (laid flat or on edge) or brick tiles in floors, channels, kerbs, aprons, etc laid beded and pointed in any mortar complete all as specified and as directed.
M&L for brickwork with sub-class 'B' bricks laid on flat, in floors bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:6) complete all as specified and as directed.
M&L for bricks, sub class 'B' bricks laid on edge in drain bedded and jointed in cement mortar (1:6) and pointed in cement mortar (1:3) complete all as specified and as directed.
M&L for brick work with sub class old size 'B' brick stright or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius built in cement mortar (1:4) in half brick thick walls complete all as specified and as directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed.
S&F for TMT bars 10 mm dia and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and as directed.
M&L for TMT steel bars 6 to 8mm dia, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
S&F for TMT steel bars 6mm dia., and over cut to length, bend to shape required, including cranking, bending spirally as in, stirrups, nibs, spacers and binders binding with and including providing mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M&L for form work to sides of concrete foundations ,footings, bases of columns ,raft and raft beams , sides and soffits ( if any) of foundation and plinth beams and similar vertical or to a batter flat rough finished surface complete all as specified and as directed.
M&L for form work to sides of pillars, posts, struts, piers, columns and stantions rough finished surface square, rectangular or polygonal complete all as specified and as directed.
M&L for form work to sides and soffits of roof beams, lintels lever shelves incl supports over hang etc fair finished surfaces of concrete flat complete all as specified and as directed.
M&L for form work to soffits of suspended slabs such as roof slab landings and similar works not exceeding 200mm thick (horizontal or slopping) fair finished surfaces of concrete flat complete all as specified and as directed.
M&L for form work to edges of concrete flates, treads break in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and ssimilar work exceeding 10cm and not exceeding 20cm wide complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in foundation including footing, plinth beams, bases of column etc complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in columns, pillars, post and struts etc complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in beam, lintel, cantilevers etc complete all as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B-1 (Nominal Mix) (Using 20 mm graded stone aggregate) as in slabs supported on wall, roof beams etc complete all as specified and as directed.
M&L for hardcore of gauge not exceeding 63 mm of broken stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1(using 20mm graded aggregate) copings, kneelers, apex stones, bed plates, kerbs not provided, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed.
M&L for precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded aggregate) as in cover slab of manholes, septic tank etc, set in cement mortar (1:4) including necessary form work, moulds etc. complete all as specified and as directed. Note : Reinforcement shall be measured and paid separately.
M&L for PCC (1:3:6) type C2 (using 40mm graded aggregate) in foundation, filling and mass concrete complete all as specified and as directed.
M&L for 100mm thick PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) as in hard standing/path complete all as specified and as directed.
M&L for forming construction joints 10mm wide and 100mm deep and filling with joints sealing compound grade 'B' complete all as specified and as directed.
M&L for 40mm thick PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) laid in panel finished even & smooth with using extra cement as in flooring complete all as specified and as directed.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.50 mm graded stone aggregate) as in under layer of tile flooring & finishing surfaces complete all as specified and as directed.
M&L for flush pointing to brick walls in cement mortar (1:3) complete all as specified and as directed.
M&L for 75 mm thick plain cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in plinth protection etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filling in proportion of bitumen and sand (1:2) complete all as specified and as directed.
M&L for rendering 10mm thick in cement mortar (1:6) on fair faces of brick work or concrete surface finished even and smooth with out using extra cement complete all as specified and as directed.
M&L for rendering 10mm thick in cement mortar (1:4) on fair faces of brick work or concrete surface finished even and smooth with out using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on other than fair faces of brick work or concrete surface finish even and smooth with out using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:4) on other than fair faces of brick work or concrete surface finished even and smooth without using extra cement complete all as specified and as directed.
M&L for rendering 5mm thick in cement mortar (1:3) on concrete surface of ceiling finished even and smooth with out using extra cement complete all as specified and as directed.
M&L for three coats of white wash on newly plastered ceiling surfaces including preparation of surfaces complete all as specified and as directed.
M&L for applying three coats of white wash on newly plastered surfaces including preparation of surfaces complete all as specified and as directed.
M&L for two coats of cement base paint over a coat of alkali resistant primer on newely plaster surfaced of walls including preparation of surface complete all as specified and as directed.
S&F for aluminum anodized glazed ventilators with frame of standard section and grill including glazing with 5 mm thick glass fixed to frame, rubber beading, handles and tower bolts etc complete all as specified and as directed.
S&F for 1000 litres capacity rotational moulded polyethylene water storage tanks (cylindrical or vertical with closed top) as per IS 12701:1996, hoisted and fixed in position including provision of 20/15mm bore medium grade pipe for connecting inlet, outlet, overflow and washout pipe complete all as specified and as directed.
S&F for 20 mm dia ball valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule complete all as specified and as directed.
S&F for 20 mm dia gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
S&F for 15 mm bore bib taps, chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and as directed.
S&F for 15 mm bore stop valves, fancey type, chromium plated cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions complete all as specified and as directed.
S&F for 15mm bore pillar tap cost copper alloy with captain heads chromium plated screwed down high pressure with or without (Hot or Cold) with long screwed shanks and fly nuts screwed for iron pipe complete all as specified and as directed.
Drilling and tapping cast iron water mains (in position) for branch connections of internal dia of 25mm bore GI pipe complete all as specified and as directed.
Supplying and laying of outer diameter of CPVC pipes 20mm bore SDR 11 and plain CPVC SDR 11 including with all fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of outer diameter of CPVC pipes 25mm bore SDR 11 and plain CPVC SDR 11 including with all fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Supplying and laying of outer diameter of CPVC pipes 32mm bore SDR 11 and plain CPVC SDR 11 including with all fittings on walls/ceiling or laying in floors complete all as specified and as directed.
Cutting chase, pinning in making good to faceing where required and pointing in cement mortar (1:3) to ends or edges of landing, and cutting chase for concealed water tubing or concealed conduit wiring etc and making good cutting exceeding 10cm but not exceeding 20cm complete all as specified and as directed.
S&F for PVC connection 15mm bore length not less than 450 mm long with both ends PTMT nuts complete all as specified and as directed.
S&F for 75 mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F for 75 mm bore PVC (SWR) pipes of single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and as directed.
S&F for 75 mm bore PVC (SWR) bends complete all as specified and as directed.
S&F for 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches complete all as specified and as directed.
S&F for 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall complete all as specified and as directed.
S&F for 110 mm PVC (SWR) bend any radius complete all as specified and as directed.
S&F for 110mm bore.PVC (SWR) junction single (single T) equal or unequal with access door complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm (300x300x7mm), over 20mm thick screed bed or bedding in cement mortar (1:6) on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade complete all as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm (400X400X7mm) in floor, over 20mm thick screed bed or bedding in cement mortar (1:6) on floors on floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade as specified and as directed.
M&L for non skid ceramic coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm (400X400X7mm) in skirting, over 10mm thick backing coat in cement mortar (1:4) set and jointed in neat cement slurry and pointed in white or coloured cement to match shade complete all as specified and as directed.
M&L for glazed ceramic coloured tiles of size 350X450X7 mm thick set and jointed in neat cement slurry and pointed in coloured cement as in vertical surfaces such as dado/skirting and facea of side bldg over and including 10mm thick backing coat in cement mortar (1:4) complete all as specified and as directed.
S&F for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay with glazing bars, devotailed or welded complete all as specified and as directed.
S&F for steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay without glazing bars, devotailed or welded complete all as specified and as directed.
S&F eor pressed steell door frame 125x60 mm for doors with one or more rebates including necessary fixing lugs hinges lock strike plates complete all as specified and as directed.
M&L for PCC (1:3:6) type C-1,(using 20mm graded stone aggregate) for cills, hold fast filling of hollow of pressed steel door frame etc. complete all as specified and as directed.
M&L for 35mm thick second class hard wood plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers, supplied and fitted to chowkats complete all as specified and as directed.
M&L for 35mm thick II nd class hard wood made at site glazed and skeleton shutters, open rebated and prepared to receive glass, guaze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.20(a); supplied and fitted to chowkhats complete all as specified and as directed.
S&F for solid PVC door frame of size 50x47 mm made out of 5mm PVC sheet reinforced with MS square tube as per specification drying as per manufacture instructions including all necessary fitting complete all as specified and as directed.
S&F for 30 mm thick factory made solid panel PVC door shutters consisting of frame made out of MS tubes for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, and bottom rail, Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, complete all as specified including locking device and all necessary fitting etc here and after complete
S&F for galvanised mild steel wire clothes 0.56 mm nominal dia of wire and average width of aperture1.18 mm complete all as specified and as directed.
S&F for 200 mm long aluminium anodised barrel barrel tower bolts of extruded section and fixed complete all as specified and as directed.
S&F for 125 mm aluminium handles cast type, anodised complete all as specified and as directed.
S&F for 100 mm long butt hinges, extruded alminium alloy with galavanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified and as directed.
S&F for 300mm long aluminium alloy anodised sliding door bolts, with haps and staples (bolt type) and fixing clips of sheet, cast oions or cast aluminium alloy and fixed. with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and as directed.
Dismantling of plain or corrugated steel sheeeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed.
S&F for prepainted galvatume aluminum zinc coating galvanised iron based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed.
M&L for prepainted galvalume aluminum zinc coating galvanised iron based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F for vitreous china squatting pan "Orissa" pattern size 580mmx440mm white with integral foot rests including 10ltrs capacity PVC flushing cistern low level with inlet, ball valve float chain and pull and brackets, flush pipe of polyethylene of low or high density or PVC 32mm dia for low level cistern complete all as specified and as directed.
S&F in repairs vitreous china semi pedestal pattern (Anglo Indian type) white connection to trap 'P' or 'S' and flush pipe etc seat cover and making good to disturbed surfaces of floor by filling with PCC (1:4:8) type D-2 to match with existing complete all as specified and as directed.
S&F for 10 ltrs PVC valveless syphonic action type flushing cistern low level white, with inlet ball valve, float and handle including bracket with 32 mm dia PVC pipe 600 mm long complete all as specified and as directed.
S&F in repairs vitreous china urinal flat back white fixed of size 465x355x 265 mm with grating union discharge pipe etc complete all as specified and as directed.
S&F in repairs wash hand basin (WHB) vitreous China white, flat back of size 350x400mm including brackets fixed complete all as specified and as directed.
S&F for swivel shower rose of PTMT any colour for fixing with 15mm pipe (Minimum weight 40 gms) complete all as specified and as directed.
S&F for aluminium anodised snap grid frame work of size 600mm x 600mm frame work for ceiling with aluminium tee section of size 23.5mm x 26.4mm x 1.4mm thick and aluminium angle section of size 36.5mm x 25mm x 1.4mm thick, for false ceiling including hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia, 40mm long including 4 mm thick non asbestos E-board, HSPC fixed to frame complete all as specified and as directed. Make : Armstrong/Everest/Saint Gobain
S&F for 3mm thick sheet glass, ordinary quality and glazing with oil putty in not exceeding 0.50Sqm each pane complete all as specified and as directed.
M&L for framed work such as grills, grating etc. with end of bars shoulderd and/or riveted welded or forged into spikes, framed guard bars, iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and ssimilar work conforming to Fe 290, Gde-E-165 complete all as specified and as directed.
S&F for steel work in tubular trasses including special shaped washers etc complete using ERW or induction but welded tubes conforming to IS 1161-1979 grade SI-240 complete all as specified and as directed.
M&L for roof truses (framed), trussed, purlins, crane gantries, rails and fasternings and heavy bracket framing (beam, tee, angle, channel or flat section) including distance pices, cleats etc. Fe-290 (Gde E-165) complete all as specified and as directed.
M&L for two coats of synthetic enamel paint on new steel surfaces over one coat of red oxide primer over 10cm width of grith including preparation of surfaces complete all as specified and as directed.
M&L for preparing newly wood or wood based surfaces of any description over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for PCC (1:3:6) type C-2 bed to 150mm bore drain pipes including packing under hunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
M&L for salt glazed stone ware drain pipes 150 mm bore, grade 'A' laid in trenches, jointed and tested complete all as specified and as directed.
S&F for reinforced concrete pipes 450mm dia, Class NP-2, laid and jointed with collers complete all as specified and as directed.
M&L for Water proofing treatment on RCC roof etc. comprising with the following operation and as specified herein below :- (a) M&L screed bed and bedding layer of Mortar 20mm thick in CM 1: 4 for roof slab mixed with water proofing compound (to be measured and paid separately) as per manufactures instruction finished even and plain complete. (b) Preparing & cleaning of fully dried cement concrete surface. (c) Applying one coat of cold bituminous primer to the plastered surface @ 0.25 litres per sqm conforming IS-3384. (d) A layer of APP based polymeric membrane membrane 3mm thick (minimum) weighing 3.5 kg per sqm reinforced with polyster non woven fabric (weighing not less than 160 gms/sqm) shall be applied over bituminous primer as specified above. Application of polymeric membrane shall be by torch application. The over lap shall be minimum 100 mm on transverse direction and 75 mm in longitudinal direction. (e) One coat of aluminium paint over the APP based membrane @ 0.11 Kg/Sqm.
Dismantling posts or struts in normal ground (wood,steel or RCC) any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed.
Excavating in post holes (or similar holes) each not exceeding 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard/dense soil complete all as specified and as directed.
Dismantling fencing wire mesh any type (barbed wire fence) complete all as specified and as directed.
S&F for fencing post, hand rails, half round or other stock section or core for wooden handrail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof complete all as specified and as directed.
S&F for galvanised, 2 strand, steel barbed wire 2.24mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanised mild stee, staples or steel pins, etc. complete all as specified and as directed. (each line wire to be measured)
M&L for concealed point wiring with FRLSH PVC insulated unsheathed multistranded copper conductor cables of 1.5 sqmm size alongwith one earth continuity conductor with FRLSH PVC insulated unsheathed multistranded copper conductor cable of 1.5 sqmm size passing through and including suitable PVC conduit with all fittings and accessories of PVC conduit (like Tee, bend etc.) complete fixed to walls /ceiling etc , including cutting chases, making good with cement mortar 1:3, terminated in and including providing modular metal flush box of suitable size with 3mm thick hylam sheet cover for fixing of switches, sockets, fan regulators etc for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed.
All as per item No. 108 above but for one 3 pin socket outlet, 5 Amps on Independent board.
All as per item No. 108 above but for one 5 Amps, 3/5 pin socket outlet on the same board with other switches.
All as per item No. 108 above but wiring with cables of size 2.5 sqmm & cables of size 2.5 sqmm as continuous earth wire for one 5/15 Amps switch socket combination on Independent board.
S&F for switch piano, flush type single pole, one way 5 Amp complete all as specified and as directed.
S&F for socket outlet 2 in 1, 5 Amp flush type complete all as specified and as directed.
S&F for switch socket combination 2 in 1, 5 Amp flush type complete all as specified and as directed.
S&F for switch socket combination 5A/16A, 5 in 1 flush type complete all as specified and as directed.
S&F for ceiling rose, 3 way PVC insulated body complete all as specified and as directed.
S&F for sheet metal enclosure for MCB DB double door single pole & neutral, 8 way with common bus bar at incomming end complete all as specified and as directed.
S&F for MCB 'C' curve double pole 6 to 32 Amps with breaking capacity 10 KA complete all as specified and as directed.
S&F for MCB 'C' curve single pole 6 to 32 Amps with breaking capacity 10 kA complete all as specified and as directed.
S&F for MCB 'C' curve single pole & neutral, 6 to 32 Amps with breaking capacity 10 KA complete all as specified and as directed.
S&F for 18 Watt surface and wall mounting type LED batten with polycarbonate housing & integrated complete all as specified and as directed. Make : Havells/Philips/Bajaj/CG
S&F for 25 W LED building security new generation energy saving and environmental friendly long life LED street light made up of pressure die cast aluminum housing with hight power LED as lighting source and lens imbedded PC Cover having TOP OPENING seperate driver cmpartment with IP 65 protection and inpact resistance of IK07 complete all as specified and as directed. Make : Havells Cat No. ENDURAPEARLSL25WLED757SASYTOPC/Philips/Bajaj/CG.
S&F for lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed.
S&F for LED bulb of 09 Watt complete all as specified and as directed.
S&F for exhaust fans AC single phase 230/240 V of size 380mm sweep 1 phase 1400 RPM complete all as specified and as directed. Make : Crompton Model No. EXHD380-4-1/Havells/Usha/Bajaj.
S&F for galvanized steel tubing light grade, with fittings and mild steel clamps nut, bolts etc. of 32mm dia bore for cable protection on pole, road crossing or ground in pillar for fixing light etc complete all as specified and as directed.
S&F for galvanished steel water tubing of size 25 mm bore medium grade ISI marked including all galvanised iron fititngs such as bends, tees, sockets, nipples & unions, flanges etc and connecting complete all as specified and as directed.
S&F for galvanished steel water tubing of size 20 mm bore medium grade ISI marked including all galvanised iron fititngs such as bends, tees, sockets, nipples & unions, flanges etc and connecting complete all as specified and as directed.
S&F for 25 mm gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
M&L for sand cushioning with dry clean sand 15cm below cable and 8cm above the cable complete all as specified and as directed. Note : Punned thickness shall be measured for purpose of payments.
Supply and laying, well burnt bricks, sub class 'B' bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
Supply and laying cable XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core complete all as specified and as directed. (Earth work, sand cushioning and bricks will be measured and paid separately under relevant items) Make : Havells/Polycab/CCI/Nicco/Gloster
M&L for earthing with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to 4.0mm GI wire by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate No. 3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B-1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade for protection of earth electrode 20 mm dia for watering complete all as specified and as directed and tested on completion.
Bimal Trading Company
NChetia and Sons Trading
M/s GANDHESWAR PHUKAN
FREEZCON
R D Enterprises
STANDARD ELECTRIC WINDERS
M/S BORAH BROTHERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .