| 1 | L1₹29.6 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹32.0 L+₹2.1 L (6.90%)Rejected-Finance MOURYA HEIGHTS SATAVNAGAR HANDEWADI ROAD HADAPSAR PUNE 28 | PUNE | MAHARASHTRA | 411028 | L2 | Rejected-Finance RATE HIGH | |
| 3 | L3₹32.1 L+₹2.1 L (7.02%)Rejected-Finance | L3 | Rejected-Finance RATE HIGH |
Tender Value
₹46.6 L
EMD Value
₹93,120
Closing Date
18 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Pune
NO 1 GEN BHAGAT MARG PUNE 411040
8525 ADDITION ALTN TO TOILETS OF BLDG NO P27 SA WARD I AND BLDG NO P16 (SA WARD II III AT ALC SPECIAL REPAIR OF TOILETS AND BATHROOMS AT BUILDING NO 59 OTM ACCOMMODATION AND PROVISION OF ENTRY GATE WITH BOOM BARRIOR AT MINTSD UNDER AGE BR II PUNE
2024_MES_639202_2
8525 GE SOUTH PUNE
Open Tender
Civil Works
Item Rate
180 days
GE South Pune
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹93,120
Yes
29 Mar 2024
27 Feb 2024
20 Mar 2024
27 Feb 2024
18 Mar 2024
6 Mar 2024
Amount
S&F in repairs Vitreous China wash down water closet pan (EWC) (pedestal pattern) white colour, including supply only pedastal pan, seat cover, flush pipe and trap, connection to drain with and including PVC flushing cistern 10 ltr capacity and flushing pipe, anti syphonage pipe etc, complete all as specified and as directed by Engr-in-charge
S&F in repair Vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing of automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe, complete all as specified and directed.
Demolition of cement concrete in ground floor and pavings n. exc. 15 cm thickness (below or above GL), complete all as specified and directed.
Taking down cement plaster from old brick / stone masonry walls etc. including racking out joints, hacking for keys and scrubbing down with water complete all as specified and directed.
S&F in repairs brass chromium plated shower rose, 125mm size with swivel joints, including fixing to steel pipe or union of 15mm bore, complete all as specified and directed.
S&F high density 40mm bore polythylene pipes (HDPE) of pressure rating 6 kg/cm2 , laid under floors with necessary socket, elbo & bend etc complete all as complete and directed.
S&F PVC (SWR) gully trap 125x110mm, setting and jointing with solvent cement, complete all as specified and directed.
S&F below counter wash hand basin of Size 550x460 including waste fittings brass chromium plated 32 mm size with long and fly nut screwed shank, complete all as specified & directed.
Supply and fix in repairs vitreous China wash hand basin of size 580 x 450 mm white, flat back with and including waste fittings brass chromium plated 32 mm with long and fly nut screwed shank excluding taps, waste chain and plug and porcelain stopper but including cast iron brackets., complete all as specified & directed.
S&F 5.5mm thick sheet glass corner shelf 300 x 300 mm (12'' x 12'') with stainless steel brackets and railing complete all as specified and as directed.
S&F health foucet with 1.00mtr flexible tube and wall hook with N.R.V. (back flow prevented) complete all as specified & directed.
S & F in repairs 15 mm bore stop valve cast copper alloy, chromium plated, fancy type, screwed down high pressure without or butterfly handle screwed both ends for iron pipes or for union complete all as specified and directed.
S&F in repairs stainless steel grating with / without waste hole, complete all as specified and as directed.
S&F 20mm gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and as directed.
S & F 15 mm bore bib taps, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
S&F 15mm bore wall mixer with provision for overhead shower with 115mm long bend pipe on Upperside, Connecting Legs & wall flange, complete all as specified & directed.
S&F aluminium powder coated dark coloured deco grill 75 mm aperture, made out of 7.5 mm plate and finished deco grill will have 7.5 mm width and 6 mm thick with rubber beading & looks etc, complete all as specified & directed.
M&L for 25 mm thick PCC 1:2:4 type B-0 (Using 12.5mm graded stone aggregate) as in floor, finished the surfaces fair & even to receive floor finishes, complete all as specified and directed.
S&F stainless steel, 304 grade, folding toilet grab bar 60 cm long including dismantling of existing grab bars complete all as specified and as directed
S&F stainless steel, 304 Grade, railling (grab bar) made of hollow tubes (above 32mm dia, medium weight, including welding, grinding, buffering polishing and making curvature (wherever required) and fiiting the same with stainless steel nuts, bolts including dismantling of existing grab bars complete all as specified and directed
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling / mass concrete, complete all as specified and directed.
M&L for PCC 1:2:4 type B-2 using 40 mm graded stone aggregate as in foundation filling / mass concrete, complete all as specified and directed.
M&L for steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction but welded tubes confirming to IS 1161-1979 grade St.-240, complete all as specified and directed.
M&L for mild steel framed work as in doors or gates of angle iron confirming to Fe-410-W (Gde-E-250) Quality-A or other section complete drilled for fixing of steel sheeting or other covering doors etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running railsand guides) and hanging, also fastening and fixing complete all as specified and directed.
S&F plates (plain or chequrred) channel, square cut or notched (ordinary and counter sunk) forming hole with out any attachment, of Fe-410-W (Gde-E-250) Quality-B, complete all as specified and directed.
M&L TMT bars, 10 mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for column, hooking ends and binding with and incl MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
S & F TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, cut to length, bent to shape required, including cranking, binding spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia, complete all as specified and directed.
Taking down wooden chowkhat or frames n. exc. 1.5 sqm each with shutter without taking off shutter from the frame complete all as specified and directed.
Taking down wooden chowkhat or frames exc. 1.5 sqm but n. exc. 4 sqm each with shutter without taking off shutter from the frame complete all as specified and directed.
M&L for hardcore of broken stone or boulders of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Moorum / red bajri filling in floors or pavings, laid in layers n. exc 15cm thick, spread, levelled and rammed including watering, complete all as specified and directed.
M&L for 100mm thick PCC 1:4:8 type D-2 (Using 40mm graded stone aggregate) as in sub base of floor, finished the surfaces fair & even to receive floor finishes, complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 type B-2 (Using 40mm graded stone aggregate) as in sub base of floor, finished the surfaces fair & even to receive floor finishes, complete all as specified and directed.
M&L for coarse aggregate for granolithic floors graded from 12.5mm to 4.75mm spreading and levelling in layers complete all as specified and as directed by Engr-in-Charge.
M&L for coloured precast cement concrete interlocking paver block of glossy finish any shape and size confirming to IS-15658-2006, 60mm thick, M-35 grade with grey cement and no pigment laid over & including 30mm thick stone dust/grit, complete all as specified and as directed.
M&L for providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets each 0.5mm thick. The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, EPDM, Neoprene, backer rods etc., complete all as specified and as directed.
S & F Solid PVC door frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with MS tube, suppling and fixing in opening complete all as per specification and as directed by Engr-in-Charge
S&F factory made solid PVC Moulded Door Shutter with particle board core 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing as directed by Engr-in-charge.
S&F stainless steel butt hinges 100mm medium weight cold rolled, complete all as specified and directed.
S&F aluminium anodised barrel tower bolt 150mm legth of exctruded section and fixed, complete all as specified and directed.
S&F 250mm long aluminium alloy anodised sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed.
S&F aluminium anodised handle fabricated type, anodised 150mm, complete all as specified and directed.
M&L for prepration of new or previously untreated steel surface and apply two coats synthetic enamelled paint over one coat of red oxide primer of any descriptiion, not otherwise described over 10cm width or girth, complete all as specified and directed.
M&L Vitrified coloured tiles 8 to 10 mm thick any shade (square / rectangular) polished, area of each tile exceeding 0.42 sqm but n. exc 1 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including screed bed of 15mm thick in CM 1:4, complete all as specified and as directed.
M&L Vitrified coloured tiles 8 to 10 mm thick any shade (square / rectangular) polished, area of each tile exceeding 0.42 sqm but n. exc 1 sqm as in vertical surface such as dado / skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including 10 mm thick rendering in CM 1:3, complete all as specified and directed.
M & L for Non skid joint free tiles, ceramic coloured, (square/rectangular) polished, area of each tiles exc. 11 sqm but not exceeding 0.18 sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick screed bed in CM (1:4) including demolition of old existing unserviceable tiles / rendering of any description including dispossed off demolished materials to a distance as directed etc complete all as specified and directed by Engineer-in-Charge.
M & L for Non skid ceramic coloured tiles of 300x300x7-8mm thick as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including 10mm thick screed bed in CM (1:4) including demolition of old existing unserviceable tiles / rendering of any description including dispossed off demolished materials to a distance as directed etc complete all as specified and directed by Engineer-in-Charge.
M & L for glazed colour ceramic tiles of size 450mm x 350mm x 7 to 8mm thick as in skirting / dado, laid over and including 10 mm thick rendering in CM 1:4 as backing coat, set and jointed in neat cement slurry and pointed in coloured cement to match with colour tiles, including triangular filleting in cm 1:4 on top edges, including demolition of old existing unserviceable plaster / tiles of any description including dispossed off demolished materials to a distance as directed etc complete all as specified and directed by Engineer-in-Charge.
M & L for glazed colour ceramic tiles of size 300mm x 600mm x 7 to 8mm thick (Colour & pattern as approved) as in skirting / dado, laid over and including 10 mm thick rendering in CM 1:4 as backing coat, set and jointed in neat cement slurry and pointed in coloured cement to match with colour tiles, including triangular filleting in cm 1:4 on top edges, including demolition of old existing unserviceable plaster / tiles of any description including dispossed off demolished materials to a distance as directed etc complete all as specified and directed by Engineer-in-Charge.
M & L for granite 18-20mm thick (of any type) work (table rubbed and polished) in flooring in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 15mm thick screed bed in CM 1:6, complete all as specified and directed.
M & L for granite 18-20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, Door cills, cooking platforms or skirting / dado and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, laid over and including 15mm thick screed bed in CM (1:6) including dismantling of old unserviceable stone slabs or tiles of any description or thickness, complete all as specified and directed.
Rounding to edges of stone slab one edge, such as in steps, cooking platform and other similar situations, complete all as specified and directed.
M&L for machine cut cuddappa stone 20 to 22 mm thick both side polished bedded & jointed in CM 1:3, laid over and including 15mm thick screed bed in CM (1:6) including dismantling of old stone slabs and tiles of any description or thickness, complete all as specified and directed.
M&L for cement concrete type B1, 1:2:4 (Using 20 mm graded crushed stone aggregate) as in coping, kerbs, coving, edging etc including necessary form work including demolition of existing cement concrete. complete all as specified and directed.
M&L for 15mm thick rendering on brick / concrete surfaces in CM 1:4 mixed with 3% water proofing compound by weight of cement, including finishing the surfaces even and smooth without using extra cement, complete all as specified and directed. Note:- Water proofing compound will be measured and paid separately.
M & L 10 mm thick rendering in cement mortar 1:6 on brick work or concrete surfaces, surfaces to be finished even and smooth without using extra cement, complete all as specified and as directed.
M&L for 5 mm thick rendering on fair faces of ceiling surfaces in CM 1:3, including finishing the surfaces even and smooth without using extra cement, complete all as specified and directed.
Supply only water proofing compound, complete all as specified and directed.
M&L for three coats white wash on new / old plastered surfaces of ceiling including preparation of new / old surfaces, complete as specified and directed.
M&L for three coats white wash on old / new plastered surfaces of walls including preparation of old surfaces, complete as specified and directed.
M & L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) including demolition of old existing brick work, solid block or stone masonry built in cement mortar or cement lime mortar complete all as specified & directed.
M&L for rendering 15mm thick in cement mortar (1:6) on fair faces of brick / concrete / stone surfaces with sagol finish cement plaster complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on stone masonry surfaces or surface other than fair face of brick-work finished even & smoth without using extra cement including taking down of old existing cement plaster complete all as specified and as directed.
M& L for 10mmm thick cement plaster in CM 1:6 on fair surfaces of brick work or concrete surfaces of wall, finished even and smooth without using extra cement including taking down of old existing cement plaster complete all as specified and as directed.
M & L for 2mm thick wall care putty on wall incluidng leveling & rubbing the surafces complete all as specified and directed
M&L for prepration of newly plastered sureface and applying two coats oil bound distemper over a coat of wall primer, complete all as specified and as directed.
M&L for prepration of old decorated sureface of walls and applying two coats oil bound distemper, complete all as specified and as directed.
M&L for Exterior aesthetic wall cladding with cladding bricks of size 225 x 70 x 20mm / 220 x 70 x 18 mm / 240 x 60 x 10 mm set & jointed in neat cement slurry and pointed in white or coloured cement to match fixed laid over and including 10 mm thick backing coat in CM 1:4, complete all as specified and directed
M&L for provision of water proofing treatment by applying oil bound bituminous primer 0.25 kg/sqm, providing & laying 4 mm thick APP modified water proofing membrane weighing not less than 4 kg/sqm, reinforced with non-woven polyster matt not less than 160 g/sqm, having softening point not less than 1400 C longitidunal tensile strength not less than 800 N/Sqcm tearing strength of 180 N by torque application including minimum 10 cm side overlap and 15 cm overlap and applying a coat of blown grade hot bitumen 90/15 over the membrane @ 1.2 kg/sqm finishing the surface with solar eflective bitmininous aluminium paint @ 100 g/sqm, complete all as specified and as directed by Engr-in-Charge and as per manufacturer's instructions.
M&L for three coats white wash on new plastered surfaces of ceilings including preparation of new surfaces, complete as specified and directed.
M&L for precast cement concrete block masonry with solid blocks exc 10 cm in width and setting in cement mortar 1:6 using PCC 1:3:6 type C-1 precast cement concrete blocks including demolition of old existing brick work, solid block or stone masonry built in cement mortar or cement lime mortar complete all as specified & directed.
M & L for water proofing treatment to sunken slab, walls, etc, shall be carried out as specified below and as directed by Engineer-in-Charge. (a) Clean the sunken portion of toilet/Baths/WCs/Kitchen thoroughly remove laitance, dirt, dust etc. (b) Forming angle fillet of size 40 mm x 40 mm along the junction of wall and floor using polymer modified mortar (“ Dr fixit” Pidicrete URP” or equivalant) (c) Sanitary pipes entering through walls and floor shall be sealed with “Dr Fixit Bathseal Tape” and the gaps to be grouted with non-shrink cementitous grout “Dr Fixit Bathseal Grout” or eqvt. Nahani traps etc to be fitted securely and the gaps around it to be grounted in the same manner. (d) Apply one coat of a Bitumen-modified polymer coating “Dr Fixit Bathseal Plus” or eqvt on all angle fillets by brush and cover it with 100mm open woven mesh when it is still wet. Apply second coat of the same coating on the angle fillets and allow it to dry completely. (e) In the remaining area, in dry substrate condition brush apply first coat of the same coating and further apply second coat when first is dry. Extend the coating upto 150mm above the FFI. Above FFI, another cementitious waterproofing waterproof coating “Dr Fixit Pidifin 2 K” or eqvt can be further applied right upto 2.1 m to waterproof the shower area also, if it is a bathroom or bath cubicles of a sanitary annex and pply second coat after 6-8 hoours and allow to dry completely. (f) After 2 to 3 days, sunken portion must be overlaid with a 50 mm thick concrete screed M 15 type B0 mixed with integral WPC (Liquid) laid to stope 1:60 towards outer face of wall. Provide 40 mm OD UPVC pipe at the lowest point with 300 mm projection beyond the outer face of the wall. Then fill up the sunken portion with lean concrete 1:5:10 type E2. (g) After completing plumbing work in the toilet/WC/Bath/Kitchen floor, tiling work (floor and dado) can be carried out using suitable Tile Adhesives and ready to make tile grouts of appd makes such as Dr Fixit, FOSROC SIKA, MC BUCHEMIE, ROFF, etc. (Note: Contractor will provided all provisions as mentioned above except 1:5:10 lean concrete which shall be measured and paid seapreatelly,
M&L for PCC 1:5:10 type E2 (using 40 mm graded brick aggregate) lean concrete for filling sunken floor etc, complete all as specified and directed.
M&L for PCC 1:2:4 type B0 (using 12.5 mm graded brick aggregate) as in coving rounded, chamfered etc on sunken floor etc, complete all as specified and directed.
M&L for RCC M-25 design mix using 20mm graded crushed stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC M-25 design mix using 20mm graded crushed stone aggregate for Columns, piers, pillars and struts etc complete all as specified and directed
M&L for RCC M-25 design mix using 20mm graded crushed stone aggregate as in beams, cantlivers, lintels etc complete all as specified and directed
M&L for RCC M-30 design mix using 20mm graded crushed stone aggregate as in roof slab / shelves / slab etc complete all as specified and directed.
Use and waste of form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter flat fair finshed surfaces complete all as specified and directed.
Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. flat fair finished surfaces complete all as specified and directed.
Use and waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions rectangular fair finished surfaces complete all as specified and directed.
Use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick for flat fair finished surfaces of concrete (Horizontal or sloping) complete all as specified and as directed
M&L for form work to edges of concrete flats, opening in concrete walls, sides of RCC / PCC bands in walls, horizontal or sloping and similar work exceeding 20 cm wide, finished the surfaces fair, complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces, complete all as speficied and directed.
M&L for ATT for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and as directed.
M& L for ATT for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured), complete all as specified and as directed.
Demolition of Reinforced cement Concrete of any description and in any position complete all as specified and directed
Dismantling structural steel work including doors, gates etc, complete all as specified and directed.
M&L for Brick work with Fly ash brick, straight or curved on plan exceeding 6.0 m mean radius built in cement mortar 1:6 complete all as specified and directed
M&L for preparing new and old surfaces of walls and applying 3mm thick wall care putty including rubbing with sand paper and applying two coats of acrylic interior emulsion over a coat of primer complete all as specifiedand as directed.
M & L for 15mm bore GI tubing medium grade including with all fitting & fixtures, fixed on walls and ceilings or laid in floors etc including taking up or down of old unserviceable steel tubing and connections, complete all as specified and directed.
M & L for 20mm bore GI tubing medium grade including with all fitting & fixtures, fixed on walls and ceilings or laid in floors etc including taking up or down of old unserviceable steel tubing and connections, complete all as specified and directed.
M & L for 25 mm bore GI tubing medium grade including with all fitting & fixtures, fixed on walls and ceilings or laid in floors etc including taking up or down of old unserviceable steel tubing and connections, complete all as specified and directed.
S&F rotational moulded polyethylene water storage tank 1000 Litres capacity ISI marked (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Pt-I with and including 20 mm ball valve high pressure PTMT with rod & high density plastic ball and tank nipple of suitable size / dia including dismantling of old unserviceable existing water tank and removing to store, complete all as specified and directed by Engineer-in-Charge.
S&F PVC (SWR) 110mm bore pipes, single socketed in any length with rubber ring joints laid in trenches or fixed to wall including demolition & breaking up of old unserviceable existing pipes PVC or AC set in CM or solvent, complete all as specified and directed.
S&F PVC (SWR) 75mm bore pipes, single socketed in any length with rubber ring joints laid in trenches or fixed to wall including demolition & breaking up of old unserviceable existing pipes PVC or AC set in CM or solvent, complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius 110 mm bore, complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius 75 mm bore, complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius 110 mm bore provided with access door, complete all as specified and directed.
S&F in repair PVC (SWR) bends any radius 75 mm bore provided with access door, complete all as specified and directed.
S&F PVC (SWR) junction, (Single Tee) equal or unequal 110mm bore with access door, complete all as specified and directed.
S&F PVC (SWR) branch piece, 110mm bore, single (Single Y) equal or unequal, with access door, complete all as specified & directed.
S&F PVC (SWR) vent cowl 110mm bore, complete all as specified & directed.
M & L for PVC (SWR) multi floor trap, dia of outlet 75mm, plain with grating including jointing with solvent cement, complete all as specified and directed.
S&F in repars brass chromium plated tubular towel rail 20 mm dia D type, 60 cm long between flanges complete all as specified and as directed.
S&F aluminium powder coated three track sliding window with two shutters of 4mm thick tinted glass of modigaurd and one shutter of stainless steel wire mesh including good quality of bearing handle, locks, PVC rubber lining etc by using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified directed by Engr-in-Charge :- Three track bottom – 20957, Three track top/vertical – 20958, Handle – 20606, Interlocking – 20605, Top and bottom – 20604.
S&F aluminium powder coated two track sliding window with two shutters of 4mm thick tinted glass of modigaurd including good quality of bearing handle, locks, PVC rubber lining etc by using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified directed by Engr-in-Charge:- Two track bottom – 20956, Two track top/vertical – 21432, Handle – 20606, Interlocking – 20605, Top and bottom – 20604.
S&F aluminium powder coated ventilator with moveable louvers including 100mm wide pinheaded glass strip by using following sections of using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified directed by Engr-in-Charge (a) Frame - 20048 (b) Glazing clip - 19352
S&F Aluminium powder coated single leaf door on pivots alongwith hydraulic door closer door lock , handle,5mm th plane glass fixed with rubber beading in top panel and glazing clips MS clamps and 12mm th laminated particle board as bottom pannel both side laminated) by using following aluminium powder coated sections conforming to catalogue of 'JINDAL' or of equivalent make complete all as specified directed by Engr-in-Charge:- (a) Rectangular tube - 14005 (b) Vertical rail - 19501 (c) Top rail -19503 (d) Middle rail -20060 (e) Bottom rail- 19511
S & F Aluminium anodised Powder coating of ivory / brown colour frame / shutters for windows / doors / Ventilator with one or more rebates including joining cleat, glazing clips, anodised aluminium snap beading for fixing, screws, anodised aluminium fittings such as peg stays, handle etc complete all as specified and directed.
S&F brass chromium plated toilet paper holder, box type, complete all as specified and directed.
S&F soap dish, stainless steel, medium size, complete all as specified and directed.
S&F Pillar taps, 15mm bore, fancy type cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed, complete all as specified and directed.
S&F stainless steel towel ring, fixed to walls, complete all as specified and directed.
S&F PTMT towel ring, fixed to walls etc. complete all as specified and directed.
S&F bottle trap (with internal Partition), stainless steel, 32mm size with 250 & 190mm Long wall connection pipes and wall flange complete all as specified & directed.
Taking down carefully exising unserviceable point wiring of any type (light, fan, socket or power), complete (fitting such as switches,ceiling rose, pendent, regulators etc) for taking credit and making good disturbed surfaces of wall, floor etc. complete all as specified and as directed.
Taking down carefully existing wooden board, main switch, MCB DB boxes with MCBs, sheet metal boxes, cut out etc of any size, any capacity from boards and making good disturbed surfaces of wall, floor etc. complete all as specified and as directed.
M & L for Point wiring using approved colour coding as per IS, with multistranded copper conductor 1.5 Sq. mm (nominal area), two single core, PVC insulated and unsheathed FRLS cable 1100 volts grade ISI-694 marked drawn through in and including heavy duty, PVC concealed conduit of white/ ivory colour including all accessories after chasing in stone /brick wall/ceiling etc, heavy duty ISI marked, with GI sunken boxes 1.2 mm thick, 60 mm deep with earth dolly duly, covered with modular white cover plate with frame suitable for modular switches, including PVC insulated multistranded copper conductor 1.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly all as specified and directed for the following :- (a) One light / fan / exhaust fan point controlled by one, one way switch 5 Amps.
(b) One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
(c) One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
All as per item No. 120 above but with stranded copper conductor 4 Sqmm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet on independent board including PVC insulated multistranded copper conductor 2.5 Sqmm (nominal area) single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified.
S & F celling rose 2/3 terminals, PVC/ polycarbonate, isolated body ISI marked , complete all as specified and directed.
S & F switch piano flush button type 6 Amp single pole one way complete all as specified and as directed.
S & F switch piano flush button type 16 Amp single pole one way complete all as specified and as directed.
S & F socket outlet 5 pin, 6 Amp flush type multipurpose complete all as specified and as directed.
S & F socket outlet 5 pin, 6/16 Amp flush type multipurpose complete all as specified and as directed.
S & F switch socket combination 2 in 1, 6 Amp flush type, complete all as specified and as directed.
S & F switch socket combination 2 in 1, 6/16 Amp flush type, complete all as specified and as directed.
Supply and fixing LED lights fitting 1x 18/20W, 1100 volt grade, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F sheet metal enclosure double door, SPN, suitable for distribution boards when MCB to be used having 200 Amp rated bus bar, 8 ways 230 V including recessed grouting in wall with PCC 1:2:4 type B-1 complete all as specified and as directed.
S & F lamp holder, PVC/ Polycarbonate type with cord grip suitable for batten/ slanting fittings, complete all as specified and directed.
S & F lamp holder, PVC/ Polycarbonate type withback plate suitable for batten/ slanting fittings, complete all as specified and directed.
Supply, fixing and testing LED IP 66 roadway luminaire with suitable size bracket high power LED as light source and electronic driver for 35 Watt LED efficacy, 100 lumens / watt CCT 5700K, CRI>70 PF 0.95, IP66, IK 07 SP5KV interval & 10 KV, SPD external, complete all as specified and directed. Make :- Bajaj / Philips / Wipro / havells
Supply and fixing integral LED Security Light luminaries 30 Watts comprising of epoxy powder coated aluminium housing, enclosed with glass cover in frame with and incluindng suitable dia of GI pipe medium grade bracket 1.20 m long bent to required shape and including taking down old unserviceable existing light fitting of any description complete all as directed by Engineer- in-charge. Make :- Bajaj / Philips / Wipro / havells
S & F for LED light fittings 10 watts batten aluminium extruded with decorative end caps including removal old unserviceable any type light fitting complete all as specified and as directed. Make :- Bajaj / Philips / Wipro / havells
S & F MCB single pole, 6 to 32 Amp, 240 V, ‘C’ Series, 10 KA, 50 Hz, complete all as specified and as directed.
S & F MCB, SPN, 40 to 63 Amp, 240 V, ‘C’ Series, 10 KA, 50 Hz, complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of the earth plate not less than 1.50 m below normal ground level connected to with and including earth lead of 4 mm dia GI wire up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth wire protected by galvanised iron 15 mm dia light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable cast iron lifting handle, GI earthing wire shall be encased in and including 15mm nominal bore GI 'light grade' tubing with all fittings from earth plate up to panel / DBs shall be provided & charcoal / salt funnel & other fittings etc. complete all as specified and as directed. Note :- (i) Unit rates includes the cost of 7.50 m 4mm dia GI earth wire & GI pipe for protection of GI earth wire for each earthing.
S&F exhaust fan, AC heavy duty metal body complete with blade & louvres shutter, voltage 230V, 50Hz, copper winding of sweep 380 mm sweep, 230V AC including fixing on walls complete with nut & bolts including making duct of suitable size in walls complete all as specified and directed
S&F exhaust fan, AC heavy duty metal body complete with blade & louvres shutter, voltage 230V, 50Hz, copper winding of sweep 300 mm sweep, 230V AC including fixing on walls complete with nut & bolts including making duct of suitable size in walls complete all as specified and directed
Excavation in over areas, n.exc. 1.50m deep and getting out in hard / dense soil, complete all as specified and directed.
Excavating in trenches not exceeding 1.5 meter in wide and not exceeding 1.5 meter depth and getting out in soft / loose soil complete all as specified and as directed
Excavating in trenches not exceeding 1.5 meter in wide and not exceeding 1.5 meter depth and getting out in hard/Dense soil complete all as specified and as directed
Excavating in trenches not exceeding 1.5 meter in wide and not exceeding 1.5 meter depth and getting out in soft disintegrated rocks complete all as specified and as directed
Returning, filling in soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all specified and as directed.
Removing excavated materials (Soil) n. exc. 50m and depositing where directed at a level n. exc. 1.50m above the starting point, complete all as specified.
Removing excavated soil to a distance exceeding 1.50 Km but not exceeding 5 Km and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sqmm 2 core, complete all as specified and as directed.
M&L for laying of Reinforced concrete pipes, class NP2 with one collar per lengh of pipe of dia 100 mm, 2 nos half round ( for bottom and top ) and before laying excavated area shall be levelled all as specified and directed Engr-in-charge.
S&F BE (Boom Barrier) automatic boom barrier time 6 to 7 sec, use in cycle 80% intensive use motor with gear & control box, one manual release key, Two wireless remote up to 6 meter boom (telescopic type) with boom rest including four nos. fastener bolts with battery backup for one operation up and down, two nos. base clamp and photocell sensor (IR Obstacle Detection Sensor including necessary PCC required as per manufacture specification complete all as specified and directed by Engrs-in-charge. Note:- Salient features of Boom barrier shall be as mentioned below:- (a) Manual release for power failure. (b) Left or right barrier option as per site requirement. (c) Limit switch with ensured safety. (d) Radio frequency based remote control. (e) Motor cooling fan for solving the problem of heat protection. (f) Boom with protective rubber band. (g) Boom with LED light. (h) Reversing of obstacle with use of photo cell.
M&L for aluminum composite panel (ACP) cladding board (3mm timex decor ACP) outdoor decor sheet with mild steel 50mmX25mm, 16 Gauge Square pipe frame, area of the board as per letters content size complete all as directed by Engr-in-charge
M&L for red acrylic or colour as approved, three dimensional letters & 3mm front A cast imported Acrylic with solid letter profile Patti red colour or colour as approved complete with water proof 3SMD LED module power supply and power adopter for 230 V AC supply complete all as directed by Engr-in-charge
M&L for providing vertical board fitting structure with 75mmX75mm, 14 Gauge, square tubing with anti crush paint complete all as directed by Engr-in-charge
M&L for stainless steel brush finish letters on walls at four feet height complete all as and directed by Engr-in-charge
Design, fabricate, supply, installation, testing and commissioning of LT panel board outdoor type, IP 54 and all as per IE rules, prewired and fabricated out of 2.00 mm thick CRCA sheet, double door with aprons, dust, vermin, weather proof duly powder coated mounted on suitable size mild steel iron angle frame 50x50x6mm welded in shape with two coats of enamel paints over a coat of red oxide primer including necessary grouting in PCC 1:3:6 type C-1 with 20 mm graded stone aggregate completed with legs 30 cm underground embedded in PCC 1:2:4 type B-1and 40 cm above ground, including connecting to cable with cable glands, lugs etc. complete all as directed and consisting of the following provisions:- (a) Aluminium bus bar 100 Amps - 02 Nos. one for phases and 01 No. for neutral duly colour sleeved mounted on epoxy insulator - 01 set (b) Incoming MCB SPN 63 Amps 10 KA, 240 V - 01 No. (c) Outgoing MCB 32 Amp SP 10 KA, 240 V - 01No.
S&F ceiling rose, 3 terminal / PVC / polycarbonate, isolated body, complete all as specified and as directed.
M&L for cutting chases, pinning in, concrete block walling & making good to facing where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc. and cutting chases for concealed water tubing and making good, cutting not exceeding 10cm girth, complete all as specified and directed.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 6.0 Sqmm nominal area and drawing into PVC non metallic rigid PVC conduit of suitable dia including one run of PVC insulated 6 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire including dismantling of old unserviceable sub main wiring including making good the disturbed surfaces complete all as specified and as directed. Note:- Two runs of 6.0 sqmm cable, one run of 6 sqmm cable and one run of PVC conduit shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4 Sqmm nominal area and drawing into PVC non metallic rigid PVC conduit of suitable dia including one run of PVC insulated 4 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire, including dismantling of old unserviceable sub main wiring including making good the disturbed surfaces, complete all as specified and as directed. Note:- Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of PVC conduit shall be measured as one unit length.
M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size 4 Sqmm nominal area and drawing into PVC non metallic rigid PVC conduit of suitable dia including two single core of PVC insulated 2.5 Sqmm (nominal area) stranded copper conductor FRLS cable as earth wire, including dismantling of old unserviceable sub main wiring, complete all as specified and as directed. Note:- Two runs of 4 sqmm cable, single run of 2.5 sqmm cable and one run of PVC conduit shall be measured as one unit length.
Gauri Associates
Suma Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .