Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.1 L+₹8,866 (0.21%)Rejected-AOC C O BHAGYODAY STORES BAZAR CHOWK NALIYA KUTCH 370 655 | KACHCHH | GUJARAT | 370655 | L2 | Rejected-AOC Other than L1 | |
| 3 | L3₹43.6 L+₹1.6 L (3.87%)Rejected-AOC 20 1 CHANDRA NIVAS APPLEBY ROAD WELLINGTON COONOOR NILGIRIS 643 232 | COONOOR | NILGIRIS | TAMIL NADU | 643232 | L3 | Rejected-AOC Other than L1 | |
| 4 | L4₹47.4 L+₹5.4 L (12.8%)Rejected-AOC | L4 | Rejected-AOC Other than L1 | |
| 5 | Rejected-Technical E 11 CWE WELLINGTON A I A II A V B I | KOLKATA | WEST BENGAL | 700001 | - | Rejected-Technical Authentic documents not produced. |
Tender Value
₹44.5 L
EMD Value
₹89,000
Closing Date
3 Feb 2020, 6:00 pmClosed
GE DSSC
GE DSSC WELLINGTON BARRACKS POST, WELLINGTON, THE NILGIRIS, PIN 643 231.
PROVN OF TOILET IN ADM BLOCK GROUND FLOOR AND SHELTER FOR GENERATOR SET(2X100 KVA) AT NFS NODE, SPL REPAIRS TO ROOF TREATMENT TO BLDG NOS 46, 47, 69, 115, JAWAHAR BLOCK, SARDAR PATEL BLOCK, RK BLOCK, RP BLOCK AND SHIVAJI BLOCK AT DSSC WELLINGTON
2019_MES_301788_2
8087/E8
Open Tender
Civil Works
Item Rate
120 days
WELLINGTON
PLEASE REFER TENDER DOCUMENT AND NIT
8 documents required · 8 mandatory
₹500
GE DSSC WELLINGTON
₹89,000
Yes
10 Sept 2020
11 Jan 2020
4 Feb 2020
11 Jan 2020
3 Feb 2020
16 Jan 2020
Amount
B/R PORTION Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and removing serviceable tiles to store and rubbish off the premises all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc and removing rubbish off the premises all as specified and directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc, but excluding ashlars facings, dressed stonework and precast concrete articles complete all as specified and directed.
M & L for precast cement concrete (1:3:6) type C-1 (using 20 mm graded stone aggregate) block masonry with solid blocks, exc 10 cm in width and set in cement mortar (1:6) complete all as specified and directed.
M & L for 25mm thick, PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in sub-base and level course, finished even and rough to receive the topping layer all as specified and as directed.
M & L for digital non-skid coloured ceramic tiles 7 to 8mm thick (square /rectangular ) area of each tile exc 0.06 Sqm but n.exc 0.11 Sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement, laid over and including 15 mm thick screed bed in CM (1:6) complete all as specified and directed.
M & L for digital glazed ceramic coloured tiles of size 600mm x 300mm x 8-10mm thick, as in vertical surface such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, laid over and including 10mm thick backing coat in CM (1:4) all as specified and as directed.
Taking down chowkhats or frames with shutter (without taking off shutters from the frames) n.exc 1.5 Sqm each all as specified and as directed.
Taking down chowkhats or frames with shutter (without taking off shutters from the frames) exc 1.5 Sqm but n.exc 4 Sqm each all as specified and as directed.
S & F second class hard wood plain, solid straight chowkats and frames wrought, framed rebated on the solid, rounded or chamfered put together with glue, pinned at joints complete all as specified and directed.
S & F for 40 mm thick plain, flush door shutters, solid core constructions, with block board core and plywood face panels, commercial type on both sides, supplied and fitted to chowkats all as specified and as directed.
S & F for 30mm thick second class hardwood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars), edges of framing moulded, chamfered or rounded fitted with cut and mitred beads for securing glass etc., size of members of shutters as in windows, ventilators etc., are provided with stiles and rails as specified in SSR Part-I, Section 8, clause 8.24(b), supplied and fitted to chowkats all as specified and as directed.
M & L for Granite stone slab flooring 16-18 mm thick of approved colour/ shade, machine cut, including grinding, polishing, moulding and rounding the exposed edges as required, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone, laid over and including 15mm thick rendering in CM (1 :4) for mounting WHB and all around door /window openings complete all as specified and as directed.
M & L for Granite stone slab 16-18mm thick in skirting/dado of approved colour/ shade 16-18 mm thick machine cut, rounding edges, including grinding, polishing, moulding and rounding the exposed edges as required, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone, laid over and including 10mm thick backing coat in CM (1 :4) all as specified and as directed.
M & L for UPVC door, white colour provided all as per manufacturer's direction and following specifications all as directed :- 1.The profile for construction of UPVC door will be of overall size 60 x 58 mm with wall thickness 2.7 ± 0.2 mm extruded sections. 2.The corners shall be plastic welded. 3.The hinge side vertical outer frame shall be reinforced with galvanized channel of wall thickness 1.2 mm. 4. The door shall be fixed to walls using 8 mm dia 80 mm long MS screws minimium 3 Nos on each side.
5. The top portion of the door shall be provided with plain glazing of 6 mm thick fixed to door shutter with UPVC standard beadings of 24.5 x 16 mm of 2 mm thick. 6. The bottom portion of door for 1 m height shall be provided with UPVC hollow board not less than 6 mm thick. 7. The door shall be provided with :- (a) Moritise lock of brass size minimum 100mm four lever with two keys all as per manufacturer's specification. (b) Two Nos of fan light pivot size 170mm on one shutter. (c) 03 Nos of 3D hinges on each shutter. 8. All the fittings shall be provided with using self tapping screws. Note: The entire fixing shall be done as per manufacturer's instructions and specification and as directed by Engg-in-Charge.
M & L for UPVC windows /ventilators with glazing, white colour provided all as per manufacturer's direction and following specifications all as directed. 1. The profile for construction of UPVC window frame shall be made of UPVC material confirming to IS 10151. 2. The frame shall be made of extruded UPVC section having overall dimension of 48 x 40 to 42 × 50 mm having wall thickness 2 mm ± 0.2 mm . 3. Corners of wall frame shall be joined by MS galvanized brackets, joints mitred and plastic welded . 4. The hinge side vertical outer frame shall be reinforced with galvanized MS tube of wall thickness 1 mm ± 0.1 mm and the tie rod shall be provided at the bottom of the frame. 5. The profiles should be single chamber system which shall provide high insulation properties. 6. The window system should be glazed with 6 mm thick plane glass fixed in window frame as per manufacturer's instruction . Note: The entire fixing shall be done as per manufacturer's instructions and specification and as directed by Engg-in-Charge.
M & L for rendering 15 mm thick in CM (1:6) on fair faces of brick work/ concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in CM (1:4) mixed with WPC as per manufacturer's instruction on fair faces of brick work /stone wall, roof fascia etc., finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid separately.
M & L for raking out joints /pointing to square rubble masonry, coursed or uncoursed in cement or lime mortar complete all as specified and as directed.
M & L for raised pointing to random or polygonal rubble uncoursed or brought upto courses in CM (1:4) complete all as specified and directed.
M & L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
M & L for preparation of new /old plastered /unplastered surfaces of walls and applying two coats of acrylic emulsion (anti-fungal) paint over a coat of primer all as per manufacturer's instrcution and as directed by Engr-in-Charge.
M & L for complete removal of existing treatment on wall by scrapping , washing, rubbing down and stopping of distempered, painted surfaces and applying two coats of oil bound distemper over one coat of primer over and including two coats of wall care putty complete all as per manufacturer's instruction and as directed by Engr-in-Charge.
M & L for complete removal of existing treatement and applying two coats of oil bound distemper over one coat of primer on ceiling surfaces complete all as specified and as directed.
M & L for preparing old painted wooden surface over 10 cm width or girth not otherwise described for, and applying one coat of synthetic enamel paint complete all as specified and as directed.
Demolition un-reinforced cement concrete in roof padding, chajjas and similar suspended work and removing unserviceable debris off the premised all as specified and directed.
Disconnecting existing tanks, of capacity exc 500 ltr but n.exc 1000 ltr, setting aside (or lowering if required) for repairs, cleaning, etc and hoisting if required reconnecting and re-fixing in position all as specified and as directed.
S & F in repairs rotational moulded polythene double layer water storage tanks, 1000 litres capacity, cylindrical, vertical with closed top, hoisted and fixed in position including 20 mm dia ball brass valves, high presured with polyethane float and fly nut complete, screwed for iron pipe all as specified and as directed.
M & L for reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span, slabs and the like etc., including necessary form work, complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
All as per Item No 30 above, but TMT bars 6 to 8mm dia & over, cut to length bent to shape, required, including cranking bending and fixing to beam slab, chajja etc all as specified and directed.
All as per Item No 30 above, but TMT 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, all as specified and as directed.
S & F WHB round bowl coloured counter top type of size 550 x 445 mm of Make : Parryware, Cat No : C0431 or equivalent make, with pillar tap of fancy type of Make : Jaquar, Cat No : KUB-35001F or equivalent make mounted over 18 mm thick polished granite slab complete all as specified and directed by Engr-in-Charge. Note : Granite work shall be measured and paid seperetaly.
S & F looking mirror of any size using 5 mm thick mirror edges, rounded, mounted on 6mm thick AC building board or commercial plywood, fixed with clips fixed to wall with suitable glass screws and cup washers complete all as specified and as directed.
S & F corner glass shelf of Make : Jaquar, Cat No : ACN 1173 or equivalent make with brass brackets, chromium plated railings all as specified and as directed.
S & F for wash down water closet pedestal pattern cascade with dual flushing cistern (Make : Parryware Popular, Cat No: C0232/86 Closet, C0711 Cistern , C2054 Cistern lid, C8300 Hush seat cover and C8016 fittings) or equivalent makes all as specified and directed by Engr-in- Charge.
S & F in repairs urinal magnum half stall type including spreader of Make : Parryware (Popular), Cat No : C 8097 or equivalent makes with integrated EFC AC with power source (Auto Flush) complete all as specified and as directed.
S & F in repairs for Vitreous china urinal partition white of size 310 x 700 mm complete including providing and fixing plugs, bedding urinal against wall in cement mortar (1:2) securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in white cement complete all as specified and directed.
S & F CP health faucet with two way bib taps 15 mm bore of Make : Jaquar, Cat No : QQT-7041 or equivalent makes including flexible tube of 1 Mtr long complete all as specified and as directed.
S & F toilet paper holder of stainless steel fixed to wall with chromium plated brass screws of Make : Jaquar, Cat No : AKP-35751P or equivalent makes complete all as specified and directed..
S & F hand drier automatic type of Make : ABS Hand drier, Model : KH07 or Kallerians or equivalent makes complete all as specified and as directed.
S & F for 32mm bore brass chromium plated bottle trap for wash hand basin with inlet and outlet, screwed for pipe or connections and with one cleaning cap and fixed complete all as specified directed.
M& L for 100 mm dia cast iron floor trap with CP grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B-1 complete all as specified and as directed.
S & F for 75mm dia PVC (SWR) pipes, type 'B', single socketed, in any length fixed to wall with suitable fixing accessories complete all as specified and as directed.
S & F 75mm PVC (SWR) vent cowl complete all as specified and as directed.
S & F for 110mm dia PVC (SWR) pipes, type 'B', single socketted, in any length laid in trenches or in floors complete all as specified and as directed.
S & F PVC (SWR ) bends 110mm dia all as specified and as directed.
S & F PVC (SWR ) junction single (Single T) equal or unequal 110mm dia all as specified and as directed.
S & F CP towel rail 20 mm dia, D type, 60cm long between flanges complete all as specified and as directed.
S & F in repairs 15 mm bore chromium palated fancy type with wall flange for iron pipe complete all as specified and as directed.
S & F in repairs 15 mm bore fancy type, chromium plated angle valves with wall flange for iron pipe or for unions and fixed complete all as specified and as directed.
S & F in repairs 15 mm bore fancy type, chromium plated conceled type stop cock with wall flange for iron pipe or for unions and fixed complete all as specified and as directed.
S & F in repairs 20 mm Gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
Taking up or down 15mm/ 20mm bore steel tubing and connection including cleaning for refixing or removal to store all as specified and as directed.
S & F 15 mm bore steel water tubes medium grade with all fittings and concelaed complete to walls and ceiling or laid in foors all as specified and as directed.
S & F 20 mm bore steel water tubes medium grade with all fittings and concelaed complete to walls and ceiling or laid in foors all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) and removing unserviceable debris off the premises all as specified and as directed.
M & L for 75mm thick, plain cement concrete (1:3:6) type C-2, (using 40mm graded stone aggregates) as in sub base finished even and rough to receive the topping layer complete all as specified and directed.
M & L for 10mm thick coloured Endura paver tiles of size 300 x 300mm of any colour in floor etc, set and jointed in neat cement slurry and pointed in white cement with coloured pigment, laid over and including 15mm thick screed bed in CM (1:6) complete all as specified and directed.
All as per item No. 59 above, but on vertical surfaces as in skirting, dados and risers of steps, complete all as specified and as directed.
S & F for mild steel work in tubular trusses, sections including special shaped washer etc., complete using ERW or induction butt welded tubes conforming to IS:1161- 1979 grade St.-240 complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings all as specified and directed by Engr-in-Charge.
S & F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering of semi-circular roof, fixed with self tapping screws all as specified and as directed.
All as per item No. 63 above but except sheeting complete all as specified and as directed. Note :- Serviceable steel sheets obtained from item No 62 shall be reused.
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer all as specified and as directed.
M & L for preparation of new or previously untreated wooden surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of pink primer all as specified and as directed.
M & L for cast iron manhole cover with frame of size 750 x 750mm (ISI marked) setting in CM (1:3) and flaunching with cement concrete (1:2:4) type B-1 complete all as specified and as directed.
S & F PVC (SWR) half rounded gutter dia 200mm with suitable brackets all as specified and as directed.
S & F PVC (SWR) pipe 110mm dia double bracketed with suitable connector to gutter and fixed on wall with suitable clamps all as specified and as directed.
Excavating in trenches, n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc, or for shafts, wells, cesspits, manholes, pier holes etc., n.exc 10 Sqm on plan and n exc 1.5m in depth and getting out in hard/dense soil all as specified and directed.
Excavating over areas, n.exc 1.5 m deep and getting out in hard rock complete all as specified and as directed.
M & L for reinforced cement concrete (Design mix) M 25 type B-1 (using 20 mm graded stone aggregates) as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses all as specified and as directed.
M & L for use and waste of timber as in formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter, for fair finished surfaces of concrete flat all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, skirting etc laid in mortar and removing unserviceable debris off the premises complete all as specified and directed.
M & L for 40mm thick, PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in subbase, finished even and rough to receive the topping layer complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, as in rafters, purlins, poles, grills etc complete all as specified and directed.
S & F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment including necessary cutting/ notching/ drilling/ riveting/ welding or connecting with bolts or nuts conforming to Fe 410 W (Gde E-250) quality 'A' complete all as specifed and directed.
M&L for PCC (1:2:4) type B1 (using 20mm gradded stone aggregate) as in coping, cills, bands, lintels n.exc 1.5m length, string courses,apex stone,bed plates,kerbs and the like incl form work, weathering, slightly rounded or chamfered angles and throating all as specified and directed by Engr-in-Charge.
M & L for cement concrete (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete in surface channels, drains etc., including necessary form work complete all as specified and as directed.
Extra labour for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred /stopped ends etc., complete all as specified and as directed.
Removing excavated material (soil) to a distance n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point all as specified and as directed.
Returning, filling in trenches, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick with excavated soil all as specified and as directed.
M & L for walling of random rubble un coursed well bonded bedded and solidly hearted built in CM (1:6) including necessary bond stones and pointing the unaccesible dressed surface with same mortar as the work proceeds all as specified and directed.
Taking down existing water proofing treatment on the roof, cleaning with wire brush etc., and removing debris outside MD land all as specified and directed.
M & L for 30 mm thick, plain cement concrete (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in roof padding / leveling course kerbs, or chamfered on edges finished even and smooth with using extra cement and mixed with water proofing compound as per manufacturer's instruction and as directed by Engr-in-Charge. Note : WPC shall be measured and paid separately.
M & L for 10mm thick screed bed or bedding layer of CM (1:3) for laying floor finishes and mixed with water proofing compound as per manufacturer's instruction and as directed by Engr-in-Charge. Note : WPC shall be measured and paid separately.
Supply only liquid water proofing compound all as specified and as directed.
M & L for 3 mm thick APP modified water proofing membrane, weighing not less than 3.6 Kg/Sqm, reinforced with woven polyester matt black finished weighing not less than 160 g/Sqm having softening point not less than 150 degree celcius, longitudinal tensile strength not less than 300 N/Sq cm , 10 cm overlap and 15 cm for end laps , over a coat of bitumen primer @ of 0.20 Kg/Sqm and finished with bituminious aluminium paint applied @ 0.10 Kg / Sqm and finished all as as per manufacturer's instruction and as directed by Engr-in-Charge. Note:The work shall be carried out by authorised appicators of manufacturer.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove and making good with CM (1:3) all as specified and as directed.
M & L for making 'V' shaped groove of cracked roof surface by cleaning the surface thoroghly from dust, dirt, moss etc., and filling groove with crack filler (acrylic based, single part sealant) complete all as specified as per manufacturer's instruction and as directed by Engr-in-Charge.
M & L for applying two coats of Ultra Seal Polyurethane water proofing membrane of Make : BOSTIK or equivalent makes, applied @ 0.75 Sqm /ltr per coat and having 1.3mm wet film thickness or all as per manufacturer's instructions over roof slab all as specified and directed by Engr-in-Charge.
Taking down cement plaster /duster bed PCC of chajja, fascia, fins, parapet of roofs etc., and making good with cement plaster 10mm thick in CM (1:3) with PCC (1:2:4) type B-1 (average thickness of PCC 25mm) as required, brushing with neat cement slurry @ 3.00 Kg/Sqm including necessary formwork and scaffolding including fixing of wire netting where required to match the existing surface complete all as specified and directed. Note : WPC shall be measured and paid separately.
M & L for preparation of new/ old ceiling surfaces by applying two coats of oil bound distemper over one coat of primer complete all as per manufacturer's instruction and as directed by Engr-in-Charge.
M & L for prepartion of old or new plastered surfaces of wall by applying two coats of oil bound distemper over one coat of primer over and including one coat of wall care putty complete all as per manufacturer's instruction and as directed by Engr-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for such as roofs, floors (other than ground floors), beams, staircase /landing, chajjas and similar suspended work etc.,( reinforcement cut as required to facilitate demolition) and removing unserviceable debris off the premises all as specified and as directed.
M & L for RCC M 25 (Design mix) type B-1 (using 20mm graded stone aggregates) as in columns , pillars, piers, posts and struts etc., complete all as specified and as directed.
M & L for RCC M 25 (Design mix) type B-1 (using 20mm graded stone aggregates) as in slabs supported on walls, beams and columns in floors, roofs, landings, balcony, canopies, deck slabs and in shelves and the like etc., complete all as specified and as directed.
M & L for RCC M 25 (Design mix) type B-1 (using 20mm graded stone aggregates) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M & L for RCC M 25 (Design mix) type B-1 (using 20mm graded stone aggregates) as in fins, fascias, louvers, parapets and railing exc 60 cm in height, newels, balustrade and the like etc, complete all as specified and as directed.
M & L for use and waste of timber as in form work to sides of pillars, posts, struts, pier, columns square, rectangular or polygonal for rough finished surface of concrete complete all as specified and as directed.
M & L for use and waste of timber as in form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; n.exc 200mm thick (Horizontal or sloping), for rough finished surfaces of concrete flat all as specified and as directed.
M & L for use and waste of timber as in formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc., for rough finished surfaces of concrete flat all as specified and as directed.
M & L for use and waste of timber as in form work to sides and soffits of fin, louvers, fascia etc. , for rough finished surfaces of concrete flat all as specified and as directed.
M & L for 5mm thick cement plastering in CM (1:4) on ceiling surfaces, finished the surface fair and even complete all as specified and as directed.
M & L for 10mm thick cement plastering in CM (1:4) on conrete surfaces of wall, finished fair and even complete all as specified and as directed.
Dismantling single layer mangalore pattern or similar tiles in roofing complete all as specified and as directed.
M & L for roof tiles, mangalore pattern, interlocking at side joints, laid dry complete all as specified and as directed.
All as per item No 107 above but exept tiles complete all as specified and as directed. Note : Serviceable tiles obtained from item No 106 shall be reused.
M & L for Ridge or hip tiles to suit mangalore pattern of roofing tiles bedded and jointed in CM (1:4) all as specified and directed.
All as per item No 109 above but exept tiles complete all as specified and as directed. Note : Serviceable tiles obtained from item No 106 shall be reused.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed.
S & F for 20mm thick second class hard wood boarding, planed on one side and edges tongued and grooved or rebated fixed with nails in any situation (except flooring and skirting) complete all as specified and directed.
Fixing only 20mm thick second class hard wood clean sawn boarding, and fixed with nails in any situation (except flooring and skirting) complete all as specified and directed.
M & L for removing vegetation /plants on roofs, wall and junction of OH tank pipes etc., on the building of rooting to any depth and injecting chemical inside the hole and filled by 80/100 bitumen mix seal the hole, finished the surface match to existing finishes of surface and making good the disturbed portion with PCC (1:2:4) type B-0 including finishing complete all as specified and as directed.
Surface excavation n.exc 30 cm deep and averaging 15cm deep and getting out in hard / dense soil all as specified and as directed.
Excavating in post holes each n.exc 0.50 cum getting out in hard/ dense soil complete all as specified and as directed.
M & L for plain cement concrete (1:2:4) type B-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete all as specified and directed.
S & F mild steel screw bolts (machine made) dia of neck exc 12mm and n.exc 20mm, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long all as specified and as directed.
M & L for hard core of broken stone or boulders n.exc 63 mm deposited, spread and levelled in layers n.exc 15cm thick, water and rammed to a surface complete all as specified and as directed.
M & L for 100mm thick, plain cement concrete (1:3:6) type C-2, (using 40mm graded stone aggregates) as in sub base finished even and rough to receive the topping layer complete all as specified and directed.
M & L for 50mm thick, plain cement concrete (1:2:4) type B-0, (using 12.5mm graded stone aggregates) as in floor by maintaining required gradient / undulation, finished even and fair complete all as specified and directed.
M & L for peparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint white or tinted with primer of any shade, complete all as specified and directed.
S&F 6mm thick Solid polycarbonate sheet as in wall cladding fixed with self tapping screwes and joints shall be sealed with silicon with and incl aluminium strip and ties as approved by GE all as specified and directed by Engr-in-Charge. Make : TUFLITE or equivalent.
E/M PORTION M & L for concealed point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked with provision of 1.5 Sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) & incl provn of modular boxes of appropriate size & thickness fixed flush to wall for mounting switches, sockets etc., with and including cutting chases for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed for the following : (a) One light/fan/call bell point controlled by one switch. Note: (i) Cutting chases and making good the disturbed surfaces is included in the unit quoted rates. (ii) Modular boxes shall be measured and paid separately. Make : Havells/Finolex/Polycab.
(b) One 5 Amps 5 Pin socket outllet on independent board complete all as specified and as directed.
M & L for concealed sub-main wiring alongwith earth wire of size (2 x 4.0) Sq. mm + (1 x 4.0) Sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC rigid conduit (medium grade) with all fittings and accessories ISI marked including cutting chases for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed. Note: (i)Two runs of PVC wire, one run of earth wire & one run of PVC rigid conduit (medium grade) shall be measured as one length. (ii) Cutting chases and making good the disturbed surfaces is included in the unit quoted rates. (iii) Modular boxes shall be measured and paid separately. Make : Havells/Finolex/Polycab.
S & F modular type switch single pole, 6 Amps one way, 1 module complete all as specified and as directed. Make : Verona of Crabtree, Cat No : ACVSXXW061 or equivalent in Legrand/C&S/ Anchor Roma.
S & F modular type socket out let, 6 Amps, 2/3 pin combined, 2 module complete all as specified and directed. Make : Verona of Crabtree, Cat No: ACVKSWW065 or equivalent in Legrand/C&S/ Anchor Roma.
S & F concealing modular metal flush box suitable for fixing switches/sockets of following modules all as directed. (a) 3 Module Make : Verona of Crabtree, Cat No : ACTXMIIX03 or equivalent in Legrand /C&S/ Anchor Roma.
(b) 6 Module Make : Verona of Crabtree, Cat No : ACTXMIIX06 or equivalent in Legrand /C&S/ Anchor Roma.
S & F modular cover plate, white with frame suitable for fixing switches/sockets of following modules all as directed. (a) 3 Module Make : Verona of Crabtree, Cat No : ACVPPCWV03 or equivalent in Legrand /C&S/ Anchor Roma.
(b) 6 Module Make : Verona of Crabtree, Cat No : ACVPPCWV06 or equivalent in Legrand /C&S/ Anchor Roma. Note for Item Nos 127 to 128 : The make of modular cover plates / flush boxes should be same as that of switches/ sockets.
S & F ceiling rose, PVC/polycarbonate, insulated body, 3 terminals and 240 Volts, ISI marked complete all as specified & as directed. Make: Havells/CG/Anchor
S & F ultra slim elegance LED lighting fixture with extruded aluminium heat sink, 20 W, 4ft energy efficient and environmental friendly incl electric connection with twin/three core cable in & including flexible conduit from ceiling rose to light fitting complete all as specified and directed by the Engr-in-Charge. Make : Havells, Cat No : ENDURALINEAR NEOBS20WLED865SPCWH or techno-commercially equivalent of Luker/Philips.
S & F compact & sturdy LED decorative fixture 10 Watts with extruded heat sink, multi purpose lighting in replacement of 2ft FTL fittings incl electric connection with twin/three core cable in & including flexible conduit from ceiling rose to light fitting complete all as specified and directed. Make : Havells, Cat No: ENDURALINEARNEO BS10WLED865SPCWH or techno-commercially equivalent of Luker/Philips.
S & F energy saving new generation 10 Watts LED, bulk head luminaire with opal diffuser with and including lamp LED 6000K & electric connection with twin/three core cable complete all as specified and as directed. Make: Havells, Cat No: RUGBYNEONFT10 WLED860SSYMTOPC or techno-commercially equivalent of Luker/Philips.
S & F exhaust fan, single phase, 250mm sweep, PVC body with their all accessories fixed properly on window/ stone wall surfaces of thickness not exceeding 50cm including making proper sized exhaust hole of 250 mm dia, Louver Shutter suitable for the same exhaust fan and which shall easily be operated with exhaust air pressure connecting/testing incl electric connection with twin/three core cable in & including flexible conduit from ceiling rose to exhaust fan connecting/testing complete. as directed. Any disturbed surfaces of wall shall be made good by cement work/plastering and matching by existing colour white/colour wash. Make: Havells ,Code:Ventil Air-DX white or equivalent in Almonard/ Usha.
S & F sheet metal enclosure for 8 way DBs double door type 240 volts, 200 Amps rated bus-bar, IP-43,IK-05 with metal door including necessary electrical connection all as specified and as directed. Make: Havells, Cat No: DHDNSHODDW08 or equivalent in L&T/ Legrand.
S & F miniature circuit breakers, single pole, C-Series 240 Volts of capacity (6-32 Amps) as ordered breaking capacity 10 KA all as specified and as directed. Make: Havells, Cat No :DHMGCSPF006-032 or equivalent in L&T/ Legrand.
S & F miniature circuit breakers, SP & N, C-Series 240 Volts of capacity (6-32 Amps) as ordered breaking capacity 10 KA all as specified and as directed. Make:Havells, Cat No : DHMGCSNF006-032 or equivalent in L&T/Legrand.
Krishna Engineering
P K ENTERPRISES
SREERAM
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .