Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹4.0 L
EMD Value
₹8,010
Closing Date
7 Jan 2022, 6:00 pmClosed
EE HPSAMB Shimla
EE HPSAMB Shimla
C/o Principal Market Yard Rampur, Distt. Una, H.P. SH Provision of Electrical Installation work Thereof.
2021_HPAMB_55003_1
HMB-EC-Tender-11/92
Open Tender
Electrical Works
120 days
Una
Please refer Tender documents.
9 documents required · 9 mandatory
₹413
EE HPSAMB Shimla
₹8,010
3 Feb 2022
24 Dec 2021
10 Jan 2022
24 Dec 2021
7 Jan 2022
24 Dec 2021
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. MAKE: Wire -Havells, Poly Cab, Finolex, RR Kabel, Metal Box-Havells, Legrand, MK Electric,RR, Kabel, Switch- Havells, Legrand, MK Electric, RR Kabel or any other approved by Engineer-in-Charge.
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. MAKE: Wire -Havells, Poly Cab, Finolex, RR Kabel, Metal Box-Havells, Legrand, MK Electric, RR Kabel, Switch- Havells, Legrand, MK Electric, RR Kabel or any other approved by Engineer-in-Charge.
Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. MAKE: Wire -Havells, Poly Cab, Finolex, RR Kabel or any other approved by Engineer-in-Charge.
Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. MAKE: Wire -Havells, Poly Cab, Finolex, RR Kabel or any other approved by Engineer-in-Charge.
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLSont including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings). MAKE: Metal Box: Havells, Legrand, MK Electric, RR Kabel, Socket: Havells, Legrand, MK Electric , RR Kabel, Switch: Havells, Legrand, MK Electric, RR Kabel or any other approved by Engineer-in-Charge.
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in FRLSont including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. MAKE: Metal Box: Havells, Legrand, MK Electric, RR Kabel, Socket: Havells, Legrand, MK Electric , RR Kabel, Switch: Havells, Legrand, MK Electric, RR Kabel or any other approved by Engineer-in-Charge.
Providing and installation of Indoor Commercial Range LED 20W -6500K Batterns with the follwings, 1) Extruded alumnium housing, 2)System Lumens-2200Lm, CRI>80, 3) CCT:6500K, THD<15%, PF>0.95, IP20, IK03, 4) Operating Temparature: -10deg C to +45deg C, 5) Input Volateg Range:140-270V including mounting the fixture, testing etc. as required complete in all respects with two year warranty . Make:- Havells , Philips, Wipro, Syska, GE, Bajaj, C&S, Panasonic, Crompton or any other approved by Engineer-in-Charge.
Providing and installation of 450mm sweep Wall Mounted fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Make: Havells, Usha, Orient, Crompton or any other approved by Engineer-in-Charge.
Providing and installation of exhaust fan Light duty, (Domestic) 300 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Make:Havells, Usha, Orient, Crompton or any other approved by Engineer-in-Charge.
Providing , installation of 50W LED Street light with polycarbonate body and aluminium heat sink, suitable for input voltage: AC 220-240V, 50/60Hz including mounting the fixture, testing etc. as required complete in all respects with two year warranty &100 lumens/watt. Make:- Philips, Wipro, Syska, GE, Bajaj, C & S, Panasonic or any other approved by Engineer-in-Charge.
Supplying and erection of street light bracket made of 32mm dia G.I. pipe 'A' class of suitable length and dia, the pipe bended to give an angle of 100 to 110 degree fitted with bolt & nuts at the top of existing pole or wall including painting the pipe with two coats of approved paint over priming coat complete in all respects as required:-
Supplying and erection of Galvanized Iron (G.I.) pipe pole 'A' quality of suitable length and dia. 5.40 mm thickness, including fixing up to a given depth below G/L.The hole of excavation about 30 cm dia. and given depth to be filled in up to 15 cm below G/L with 1:3:6 cement concrete and there above plinth with 1:2:4 cement concrete up to a height of 45 cm from G/L. The radial thickness of the plinth above G/L should not be less than 6.35 cm and sufficient to completely flush a 180 mmx100 mmx 45 mm deep, glass filled Nylan F.R. grade box for housing a 16 Amp. MCB, the outer surface of the plinth to be finished with 1:3 cement plaster 6 mm thick, the fuse-box shall have a water tight cover, including painting of pole with two coats of approved color, brand and manufacture of paint over a priming coat complete in all respects as required:- 8 Meter long having nominal bore dia. 125 mm planting depth 120 cm with pit depth 135 cm.
Supplying and fixing following ways Three phase sheet steel MCB Distribution Board 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Make: Havells, Legrand, L&T or any other approved by Engineer-in-Charge.Double door-8 way
Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: Havells, Legrand, L&T or any other approved by Engineer-in-Charge. 40 Amps. Cat-A.
Supplying and fixing Douple pole 6 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: Havells, Legrand, L&T or any other approved by Engineer-in-Charge.
Supplying and fixing Single pole 6 amps to 32 amps rating, 240/415 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: Havells, Legrand, L&T or any other approved by Engineer-in-Charge.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. MAKE: Wire -Havells, Poly Cab, Finolex, RR Kabel or any other approved by Engineer-in-Charge.2x1.5 Sq. mm.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. MAKE: Wire -Havells, Poly Cab, Finolex, RR Kabel or any other approved by Engineer-in-Charge2x2.5 Sq. mm.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. MAKE: Wire -Havells, Poly Cab, Finolex, RR Kabel or any other approved by Engineer-in-Charge2x4.0 Sq. mm.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and fixing 8 SWG (4.00 mm dia) copper wire on surface or in recess for loop earthing as required
Providing, laying and fixing of aluminium conductor, PVC insulated and PVC sheathed, armoured/ XLPE power cable, working voltage 1100 volts grade on surface etc. of the following size:-2 x 6 Sq.mm
Supplying and fixing of Suitable single compression cable end jointing with gland and Aluminium lugs for the following cables 2 x 6 Sqmm
AJAY KUMAR GOVT CONT
Vikas soni
KISHORI LAL SHARMA GOVT. CONTRACTOR
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid