Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹7.5 L+₹96,736 (14.9%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest | |
| 3 | L3₹7.7 L+₹1.2 L (19.1%)Rejected-Finance 29 GANDHI NAGAR VETERINARY COLLEGE ROAD BIKANER 334001 RAJ | BIKANER | RAJASTHAN | 334001 | L3 | Rejected-Finance Other than Lowest | |
| 4 | L4₹8.2 L+₹1.7 L (25.8%)Rejected-Finance | L4 | Rejected-Finance Other than Lowest |
Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
31 Oct 2020, 6:00 pmClosed
GE NASIRABAD
GE Nasirabad Nasirabad cant, Pin 305601 (raj)
SPECIAL REPAIRS TO OVERHEAD LINES WITH UNDER GROUND CABLES AND ELECTRIC PANELING, SPECIAL REPAIRS OF EXTERNAL ELECTRIC SUPPLY SYSTEM AT RMS AREA AND PROVIDING TWO DRINKING WATER COOLER AND ONE REFRIGERATOR IN RMS AJMER MIL CANTT
2020_MES_381671_1
8104/E8
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
NASIRABAD AND AJMER
AS PER NIT
6 documents required · 6 mandatory
₹500
GE Nasirabad
₹15,000
Yes
10 Dec 2020
28 Sept 2020
2 Nov 2020
28 Sept 2020
31 Oct 2020
19 Oct 2020
28 Sept 2020 - 12 Oct 2020
Amount
Dismantling of old unserviceable ACSR conductors from existing PCC/RCC/Steel Poles, complete all as directed.
Dismantling of old unserviceable insulators, any type & any size from PCC/RCC/Steel poles complete all as directed.
Dismantling of Cross arms of MS channel or angle section etc from poles complete all as directed.
Taking out old unserviceable UG cable with aluminium conductor of any size complete all as specified and directed.
M&L for earthing complete with galvanized steei earth plate electrode 60cm X 60cmx 6mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level and connected to galvanized strip 32 X 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I, connected to OH conductor on pole/ Panel/ main switch board etc all as specified or indicated and testing on completion including provision galvanized strip protected by 40 mm bore, light grade pipe and watering pipe shall be 20 mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI strip and protection pipe upto 7.5 m complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated, armoured heavy duty cable of size 10 sqmm 2 core with stranded aluminium conductor suitable for rated voltage of 1100 volts grade laid in trenches / pipe / ducts or on pole including all types of double compressed brass aluminium lugs, cable glands complete all as specified and directed, Note :- Excavation, earth work, sand cushioning and cable cover will be measured and paid separately.
All as per descrition of item No 6 here-in-before but size 10 Sq mm, 4 core.
All as per descrition of item No 6 here-in-before but size 16 Sq mm, 4 core.
All as per descrition of item No 6 here-in-before but size 25 Sq mm, 4 core.
All as per descrition of item No 6 here-in-before but size 35 Sq mm, 3.5 core.
All as per descrition of item No 6 here-in-before but size 50 Sq mm, 3.5 core.
All as per descrition of item No 6 here-in-before but size 70 Sq mm, 3.5 core.
Excavation in trenches in any type of soil, not exceeding 1.5 metre deep and not exceeding 1.5 metre wide for laying of cables, RCC/Steel tubular poles/stays and struts etc. and getting out including trimming sides and forming bottom surface, complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each layer as in backfill in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested complete all as specified and directed.
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified & directed.
Supply and laying old size brick covering with width equal to length of brick as the mechanical protection to cable with well burnt sub class 'B' laid in trenches flat complete all as specified and directed by Engineer-in-charge.
Supply and laying dry river sand for cable cushioning in trenches to required width at bottom and top of cable including spreading, levelling, watering and consolidation complete all as specified and directed by Engineer-in-charge. Note:-Punned thickness only shall be measured and paid.
M & L for 50 mm bore galvanized iron pipe, light grade (ISI marked) with all fittings laid in trenches or on pole, crossing of road, fixed on wall for protection of cables complete all as specified and directed.
All as per description of serial item No. 18 above but 40mm bore pipe.
All as per description of serial item No. 18 above but 25 mm bore pipe.
M & L for Boring holes upto 2 metre depth in soil for laying of under ground cable complete all as specified and directed.
Supply and connection in repair PVC insulated unsheathed copper conductor cable 2.5 Sqmm three core multi-standard 1100 volt grade single core for connecting street light fitting complete all specified and directed.
S & F Plastic one piece moulding HDPE street light control box with locking arrangement made out of HDPE including 01 No MCB SP 6 Amp 240 Volts complete with 02 Nos aluminium busbar of rating 63 amps for phase and netural on porcelain based insulators and fixing clamps to pole with FI clamp 25 X 3mm for street lights, complete all as required and directed at site. Make:- Sintex/Hensel/SHI/Brite
S&F MCCB, 160 Amp, 4 Pole, 36 KA, 36 Hz, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , including spreader terminals and phase barriers including taking down old unserviceable MCCB complete all as specified and directed. Make- Legrand/L&T/Siemens
S&F copper bus bar 300 Amp on existing panel complete all as specified and directed.
S&F MCCB, 63 Amp, 3 Pole, 16 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , including spreader terminals and phase barriers including taking down old unserviceable MCCB complete, all as specified and directed. Make- Legrand/L&T/Siemens
S&F MCCB, 160 Amp, 3 Pole, 36 KA, 415 V, thermal magnetic release type, Ics=100 % Icu, with adjustable overload setting and adjustable short circuit setting , including spreader terminals and phase barriers including taking down old unserviceable MCCB complete all as specified and directed. Make- Legrand/L&T/Siemens
M&L for point wiring with 1.5 Sqmm, PVC insulated, unsheathed, stranded copper conductor single core FRLS cable, IS-694 marked, drawn through and including non metallic rigid PVC concealed conduit 20mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel terminal switch box 1.6mm thick with bakelite laminated sheet top cover 3mm thick, brass screws and cup washers including 1.5 Sqmm stranded copper conductor PVC insulated green in colour as continous earth conductor connected to common earth and earth dolly with all accessories for One 3 pin 5 Amp socket on independent board.
All as per item No. 31 here-in-before but with 2.5 Sqmm, for one 5 pin 5/15 Amp socket on independent board including 2.5 Sqmm stranded copper conductor (FRLS) PVC insulated green in colour as continous earth conductor connected to common earth.
S&F switch piano flush type 5 Amps, single pole one way 240 volts.
S&F switch piano flush type 15 Amps, single pole one way 240 volts.
S&F Socket outlet 3 Pin 5/6 Amp flush type.
S&F socket out let 2 in 1, multipurpose 3 pin 15/16 Amp flush type, ISI marked complete.
S&F water cooler fully stainless steel, electric driven , single phase, having storage capacity 80 Ltr and nominal cooling capacity of 40 Ltr/hr, with stainless steel tank complete all as specified and directed. Make- Voltas, Model- WS FS 40/80 NP R134a or equivalent model from Blue Star/Usha
S&F refrigerator , frost free, double door, electric driven , single phase, capacity 310 Ltr, 3/4 star rated complete all as specified and directed. Make- Godrej, Model- RT EON 311/LG Model - GL-T322RPZU/Haier Model- HRF-3304BS.
S&F voltage stabilizer for automatic operation, single phase , naturally air cooled indoor type, in put voltage between 130 V to 290 V , out put voltage 230 volt with accuracy of ± 2.5% and of capacity 1.0 KVA complete all as specified and directed. Make- V Gaurd, Model- VGSD 100 Supreme or equivalent model from Microtec/Blue Star
S&F on wall/roofs/ceiling GI tubing "medium" grade 15 mm dia including necessary screwing and all fittings (Tee,union, nipple, reducer, elbow etc) as required at site complete all as specified and directed by Engr-in-Charge.
S&F Gun metal gate valve with iron wheel head, both end screwed for iron pipes of 15 mm bore complete all as specified and directed by Engr-in-Charge.
S&F PVC connection pipe 15 mm dia with PTMT nuts of length 450 mm complete all as specified and directed by Engr-in-Charge.
M/S RAKESH CHOUDHARY
MITTAL ENTERPRISES
M/s Kishan Gopal Agarwal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .