AGM (E-E)
S. V. Airport, Raipur.
Modification of Part of Old Terminal Building Ground Floor for development of International Air Cargo Terminal at S. V. Airport, Raipur. Subhead Electrical and FADS works.
2026_AAI_292560_1
AAI/RPR/AGM/EE/CW/26-27/ENIT-5
Open Tender
Electrical Works
Item Rate
180 days
S. V. Airport
as per NIT criteria
6 documents required · 6 mandatory
₹1,180
₹1.8 L
29 Sept 2026
29 Sept 2026
22 Oct 2026
29 Sept 2026
21 Oct 2026
29 Sept 2026
29 Sept 2026 - 7 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SH-I: Distribution Board MCB and Internal Electrical Works. | - | - | - | - |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable PVC box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Group C | 100 | Each | 1,730 | ₹1,73,000 |
| 3 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required
Group C | 110 | Each | 788 | ₹86,680 |
| 4 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | 350 | Meter | 461 | ₹1,61,350 |
| 5 | Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 250 | Meter | 1,138 | ₹2,84,500 |
| 6 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. | 300 | Meter | 498 | ₹1,49,400 |
| 7 | Supplying and fixing of 4 way (4 + 12) , Double door horizontal type PPI, three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) | 8 | Each | 4,483 | ₹35,864 |
| 8 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 64 | Each | 277 | ₹17,728 |
| 9 | Supplying and fixing of 63 Amps. rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 8 | Each | 1,049 | ₹8,392 |
| 10 | Supplying and fixing of 63 A rating, 4 pole, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. | 8 | Each | 3,387 | ₹27,096 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.57 MB
TenderDocument.pdf
Tender Documents • 13.01 MB
BOQ_341251.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .