Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹198.44Accepted-AOC | ₹198.44 Quoted ₹198.47 | L1 | Accepted-AOC LOWEST QUOTED BIDDER |
| 2 | L2₹2.1 Cr+₹2.1 Cr (10728736.1%)Rejected-Finance | ₹2.1 Cr+₹2.1 Cr (10728736.1%) | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 3 | L3₹2.3 Cr+₹2.3 Cr (11455165.3%)Rejected-Finance | ₹2.3 Cr+₹2.3 Cr (11455165.3%) | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 4 | L4₹2.5 Cr+₹2.5 Cr (12440729.8%)Rejected-Finance | ₹2.5 Cr+₹2.5 Cr (12440729.8%) | L4 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
| 5 | Rejected-Technical FLAT NO 5 10 3 73 6 AMAR APARTMENTS TEACHERS COLONY EAST MARREDPALLY SECUNDERABAD 500026 | SECUNDERABAD | HYDERABAD | TELANGANA | 500026 | - | - | Rejected-Technical REJECTED DUE TO REVOCATION OF TENDER |
Tender Value
₹2.0 Cr
EMD Value
₹2.7 L
Closing Date
4 Mar 2023, 6:00 pmClosed
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD BOWENPALLY POST SECUNDERABAD 500011
EXTERNAL SERVICES FOR ALTERNATIVE VENUE FOR PARADE GROUND AT AFA HYDERABAD
2023_MES_577559_1
86701/E8
Open Tender
Civil Works
Item Rate
180 days
GE AFA HYDERABAD
AS PER NIT
9 documents required · 9 mandatory
₹1,000
Yes
GE AFA HYDERABAD
₹2.7 L
Yes
14 Mar 2023
27 Jan 2023
6 Mar 2023
27 Jan 2023
4 Mar 2023
18 Feb 2023
27 Jan 2023 - 11 Feb 2023
Amount
SCHEDULE 'A' PART -I (B/R PORTION) :- Excavationover areas not exc 1.5 mtr deep and getting out in hard / dense soil complete all as specified and as directed.
M & L for Hard core of gauge n exc 63 mm deposited ,spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface, using broken stone or boulders,complete all as specified and as directed.
M&L for 75 mm thick PCC 1:4:8 type D-2 mix using 40 mm graded stone aggregate as in foundations filling and mass concrete as in floors, sub base etc complete all as specified and as directed.
M&L for Sand filling under floors or in foundations including watering , well ramming and consolidation complete all as specified and as directed.
M&L for Machine pressed precast concrete interlocking paver blocks with grey cement and pigment any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and as directed.
M&L for PCC 1:2:4 tpe B-1 mix using 20 mm graded stone aggregate as in kerbs , road cutting , hard standing , coping of poles and the like including weathering, slightly rounded or chamfered angles and throating etc as required including necessary form work complete all as specified and as directed.
Removing excavated material / soils exc. 1.50 km but not exc. 5.0 km and depositing where directed complete all as specified and as directed.
M&L for Pre-cast cement concrete solid block masonry exc 10 cm in width with PCC 1:3:6 type C-1 mix using 20 mm graded stone aggregate and setting in mortar 1:6, complete all as specified and as directed.
M&L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 and rendering is to be finished even and smooth without using extra cement complete all as specified and as directed.
M&L for Chequered cement concrete tiles 300 mm x 300 mm x 25 mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors laid over 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
Excavation in trenches not exc 1.5 mtr width and not exc 1.5 mtr in depth for foundation or etc or for shafts , wells , cesspits , manholes , pier holes etc n exc 10 sqm on plan and not exc 1.5 mtr in depth and getting out in haard / dense soil, complete all as specified and as directed.
Excavation in trenches not exc 1.5 mtr width exc 1.5 mtr in depth but not exc 3.0 mtr in depth for foundation or etc or for shafts , wells , cesspits , manholes , pier holes etc n exc 10 sqm on plan and not exc 1.5 mtr in depth and getting out in haard / dense soil, complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation or for erection of poles, stays, laying cables, stays etc and getting out in soft / loose soil complete all as specified and as directed.
Returning & filling of the excavated earth including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and as directed.
Removing excavated soils not exc 50 mtr and depositing where directed at a level not exc1.5 mtr above the starting point complete all as specified and as directed.
M & L for cement concrete PCC 1:4:8 as in foundations, filling and mass concrete type D-2 mix using 40 mm graded stone aggregate, complete all as specified and as directed.
M&L for Plain Cement Concrete 1:2:4 Type B-1 mix (using 20 mm graded stone aggregate) as in benching of man holes including forming centre channels half round or 1/4 section complete all as specified and as directed.
M &L for PCC 1:3:6 type C-2 mix (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore complete all as specified and as directed.
M &L for PCC 1:3:6 type C-2 mix (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 200 mm bore complete all as specified and as directed.
M&L for Plain Cement Concrete 1 1:3:6 type C-1 mix (using 20 mm graded stone aggregate) as in coping including necessary form work complete all as specified and as directed.
M&L for pre-cast RCC slabs as in manhole covers in 1:2:4 type B-1 mix using 20 mm graded stone aggregate, set in cement mortar (1:4) including use and waste of form work complete all as speciied and as directed.
M&L for 150 mm boe reinforced concrete pipes of class NP-3 with one collar per length of pipe including setting in cement mortar as required complete all as speciied and as directed.
M&L for 200 mm boe reinforced concrete pipes of class NP-3 with one collar per length of pipe including setting in cement mortar as required complete all as speciied and as directed.
M&L for TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as speciied and as directed.
Description all as per Ser Item No 23 above but 5 mm dia and over up to and including 10 mm dia an in stirrups , spacers and binders complete all as speciied and as directed.
M&L for Extra for forming fair finished drain or channels of 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred / stopped ends etc complete all as speciied and as directed.
M&L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and rendering is to be finished fair and even without using extra cement complete all as speciied and as directed.
M&L for Plain Cement concrete 1:3:6 tyep C-2 mix using 40 mm graded stone aggregate as in foundations,filling and mass concrete complete all as speciied and as directed.
M&L for RCC M-25 as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc complete all as speciied and as directed.
M&L for RCC M- 25 as in Columns, pillars, piers, posts and struts etc complete all as speciied and as directed.
M&L for RCC M-25 as in Beams, cantilevers, bressummers, lintels over 1.5 mtr clear span complete all as speciied and as directed.
M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams; and similar work; vertical or to batter for rough finished surfaces of concrete flat using steel form work complete all as speciied and as directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunch ings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces of concrete flat using steel form work complete all as speciied and as directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surfaces of concrete flat using steel form work complete all as speciied and as directed.
M&L for 18 mm thick Granite (of any type) work (table rubbed and polished) for wall lining (veneering to wall) over scredd plaster 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as speciied and as directed.
Supply and fix stainless steel backlit lettering 41 mm thick 300 mm height including necessary arrangement for fixing over granitre stone walls complete all as speciied and as directed.
Supply and fix stainless steel backlit lettering 20 mm thick 230 mm height including fixing over granitre stone walls complete all as speciied and as directed.
Supply and fix Stainless steel Air force Logo with crust 600 mm to 900 mm size including necessary arrangement for fixing over granitre stone walls complete all as speciied and as directed.
M&L for Plain Cement Concrete 1:2:4 type B-2 mix using 40 mm graded stone aggregate as in foundations,filling and mass concrete complete all as speciied and as directed.
M&L for 60 mm thick precast cement concrete louvres and jallies (measured soild) with PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate including all mouldings but excluding frame set in cement mortar 1:4 complete all as specified and as directed.
S&F MS Tubuler trusses, purlins,etc including special shaped washers etc complete using ERW or induction butt welded tubes confirming to IS 1161- 1979 grade St 240 complete all as specified and as directed.
M&L for Preparation of new or previously untrated surfaces of steel and iron surfaces of any description over 10 cm width or girth and aplying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
S&FAluminium Composite Panel 4.0 mm thick of approved colour and shade of Alu Bond or equivalent fixed with self tapping screws on aluminium powder coated frame work weight not less than 0.55 Kg/Rm in any shape and size complete all as specified and as directed.
M&L for MS / Cast Iron post as in railings 80 cm height @ 2 mtr c/c with MS chain 12 mm dia one row complete all as specified and as directed.
M&L for Preparation of new or previously untreated surfaces of steel and iron surfaces of any description over 10 cm width or girth and applying two coats of aluminium paint over a coat of primer complete all as specified and as directed.
SCHEDULE 'A' PART - II (E/M) PORTION :- Supply install testing and commissioning Silent type water cooled Diesel Engine Generating set 415 volts 100 KVA/ nearest available higher size in KVA, 3 phase 0.8 power factor, 50 Hz, 1500 RPM self exicited self regulated brushless AC generator including acoustic enclosure suitable for ambient condition at Hyderabad (Dundigal) and confirming to condition under IS 10002, 13364 Part I 1992, BS 5514/5000 with the following :-
(i) The capacity of Generator set shall be net after all the derating factors as per relevant IS/BS Standards design.
(A). Alternator :- Standard design alternator rated at 100 KVA/ nearest available higher capacity at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof brushless design with winding in pole faces, insulating class 'H' and voltage regulation of + 1% at rated voltage from no load to full load. The alternator shall be confirming to BS 5000, IS: 13364 Part I (1992) and shall be in position to generate supply with frequecy regulation with in + 1% tolerance. The alternator will be suitable for tropical climate.
i) Insualation class - 'H'
ii) Temparature rise Class - 'H'
iii) Excitation : Self Excited
iv) Regulation performance: The voltage is kept constant with + 1%.
v) Frequency regulation + 1%
(B) Diesel Engine : - Adequate capacity of Diesel engine water cooled, multi cylinder multi stroke direct injection type to drive independently the 100 KVA alternator considering de-rating factor as per site conditons, directly coupled through flexible coupling, cold starting 1500 RPM, as per relevant IS/BS specifications complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:-
i) Fly wheel with housing
ii) Cooling system :- Moulded radiator with fan & belts.
iii) Cooling Water pump : - Centrifugal type belt driven.
iv) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia with MS pipe medium grade with Turbo charger, Exhaust manifold
Silencer : Residential type
v) Fuel System :- Fuel injection system with fuel injectors, fuel injection controlled by solenoid switch and governer for 1% speed /frequecy regulation, electrically operated or as recommended by OEM, with suitable fuel filters and connecting hoses.
vi) Lub oil System :-
Lubricating oil filter and tube circulated with suitablly integrated lubricating oil pump.
vii) Air Intake System :-
Air intake Manifold and air filter dry type.
viii) Governer mechanical type
ix) Starting System :- Electric Self starter with and including battery charging alternator 12 Volts DC.
x) Batteries :- Batteries of maintenance free of capacity 12 V, 180 AH or as recommemded by OEM complete with copper conductor multistranded leads of suitable length from self starter to the battary terminals complete with initial charge and initial fill of electrolyte all as specified.
Start and stop push button
Ignition key / Switch
Radiator with blower fan & first fill of Corrosion inhibitor coolant coolant and oil
xi) Generator Monitoring Panel : - Comprising of all standard items as per standard manufacturing, iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolant temperature indicator, Battery volt display.
xii) Safety Controls : - Engine low lube oil pressure high water temperature and over speeding of engine.
xiii) Coupling arrngement : - Flexible coupling
xiv) Accessories :- AVM Pads built- in or separtely mounted to manufacturer base frames.
xv) Base Frame : - Made out of ISMC of sturdy design made of MS channel with necessary reinforcement and predetermined holes as per manufacturer.
xvi) MS/Steel flexible pipe line to and from the fuel tank to the DG Set.
xvii) Battery Charger shall be provided as per manufacturer guidelines
xviii) The DG Set shall comply to the emission limits requirement as per Govt of India, Gazette notification No bearing No 595 dated 11 Dec 2013 and No 167 dated 31 Mar 2014. The DG Set shall be complied with all test requirements as stipulated in the gazette notification. All relevant test results from NABL accredited lab shall be produced to GE.
C) Civil Works :-
All civil works including PCC plat form and related foundations including for panel and equipments and making good of disturbed area during installation and commissioning of genset. The depth and size of the foundation and PCC as recommended by the manufacturer however the height of the plinth shall be not less than 450 mm from the ground level.
Note:- The contractor shall arrange for artificial load resistive for testing of DG Set at site and the cost is deemed to be included in the above offer including fuel for testing.
D) Acoustic Enclosure:- Manufactured by OEM suitable for 100 KVA/ nearest higher size available KVA DG Set.
(i) Tested by NABL approved lab as per CPCB
(ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board.
(iii) The generating set battery should be inside the enclosure.
(iv) Fuel tank should be inside the enclosure, however, the fuel storage shall be enough for 12 hrs continuous operation. If required contractor may arrange outside fuel storage capacity to achieve this
(v) Construction Details/specification are as follows : -
a) Outer body :- CRCA Sheet of 1.6mm thick.
b) Doors :- CRCA sheet of 1.6 mm thick
c) Sound Insulation :- 60 mm thick rock wool(minimum density 64kg/Cum)/ fire resistance foam/puff or as per OEM recommendations to achieve desired decibel of sound level
vi) The acoustic should be composite in construction and fully assembled integral unit.
vii) The DG Set should be provided with external Emergency stop push button.
viii) The enclosure should be suitably internally illuminated by CFL/FTL/LED Lamp fittings.
ix) The noise level should be 75 dB at 1m under free field conditions.
x) The acoustic enclosure parts shall be of powder coated after pre treatment process. The base frame should be painted with epoxy based black shade.
Note :- (i) The complete DG Set shall be procured from authorised OEM of the manufacturer of engine. A certificate in this connection shall be submitted to the GE. (ii) Air circulation system to achieve desired inside temperature of acoustic enclosure, if required shall be provided as per OEM recommendation. (iii) The quoted rate shall be deemed to be inclusive of 12 hours test run at site as specified in PS and IS requirements in presence E/M Offr (IEM) detailed by Accepting Officer , all testing arrangements/ equipments shall be made available by the contractor for tests. (iv) The quoted rate shall be deemed to be inclusive of first fill of lubricant oil, DHPP for 12 hours testing and final successful acceptance test. (v) Anything missed out above but technically required for efficient working of DG Set is deemed to be included in quoted rates.
E) AMF Panel :- AMF panel shall integrated with the DG set be made out of CRCA sheet 14 gauge powder coated dust and vermin proof totally enclosed and consisit the following: (a) Microprocessor based generator set monitoring and control system consists of 16 Charactor 2 line LCD disply and to monitor operator interface, fault history, alternator data, Engine data, provision for service adjustement and caliberation of DG control functions, Engine controls,engine protective functions, alternative protective functions etc. (b). Instrument fuses and control wiring. (c). Indication lamps for Set running and load on. (d). Aluminium bus bar TPN for 250 Amps for RYB & 125 Amps for neutral complete for in and out terminals wiring with PVC insulated single core copper conductor multistranded wire of 1100 volts grade of suitable capacity including CTs etc. (e). 4 pole MCCBs 125 Amps, 25 KA adjustable type - 02 Nos for DG and Commercial supply control. (f) Digital type tamper proof energy meter with suitable CTs.
Design, supply, erection, testing and commissioning of indoor type LT feeder pillar box platform mounted (to be mounted on the P.C.C. brick pedestal), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating not less then 400 amps, Spreader link to incoming/outgoing MCCB for termination of incoming/outgoing cable and Aluminium connecting bars of suitable size (R-Y-B-N) for outgoing cables, duly fabricated in a CPRI approved / certified factory having modern fabrication and testing facility which includes at least seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.15 mm thick CRCA mild steel sheet and 2.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and mild steel angle (50x50x5mm) legs of length 30 cm at bottom, suitable for mounting on the pedestal, The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :-
(i) Change Over Switch 250 Amps, front operated, open execution type - 02 No Make : L&T or equivalent
(ii) MCCB 4 pole 250 Amps, 36 KA, 415 Volts, 50 Hz, AC supply, adjustable thermal (80% to 100%) and fixed magnetic release (as incoming) - 01 No Make : L&T or equivalent
(iii) MCCB 4 pole 100 Amps, 25 KA, 415 Volts, 50 Hz, AC supply, adjustable thermal (80% to 100%) and fixed magnetic release (02 outgoing + 01 spare) - 04 Nos Make : L&T or equivalent
(iv) MCB 4 pole 40 Amps, 16 KA, 415 Volts, 50 Hz, AC supply, (as outgoing) - 01 No Make : L&T or equivalent
(v) MCB 6 to 32 amps rating 'C' series SPN (as building/area lighting) - 03 Nos
(viii) LED indicating lamps with holder for main supply - 1 Set of 3 (R-Y-B)
(ix) Instrumental control wiring MCB 3 Amps - 03 Nos
Supply and fixing LED flood light 120 watt white colour energy savings, environmental friendly, long life, exclusive innovative die-cast aluminium IP 65 fllood light with high power LEDs as light source, including all fixing arrangement complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3½ core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 185 sq mm 3½ core complete all as specified and as directed.
M&L for Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and as directed.
Supply, lay /spread in trenches, river sand including cleaning, spreading, levellng, punning for laying/cushioning of cable complete all as specified and as directed.
M&L for Tubes, 'light grade' galvanised 50 mm dia, with all fitting such as socket, elbow,bend etc and fixed complete to walls and ceilings or laid in floors / trenches / poles complete all as specified and as directed.
M&L for Tubes, 'light grade' galvanised 80 mm dia, with all fitting such as socket, elbow,bend etc and fixed complete to walls and ceilings or laid in floors / trenches / pole complete all as specified and as directed.
Supply and fixing Eros casting poles family of decorative cast iron post top pole of height 3 mtr cast iron with including provision for cable entry at base section is to be provided including base plate with provision of fixing in PCC foundation complete all as specified and as directed. Make :- Havells- Eros pole, Cat Part No EROSPOLET03030M or or equivalent approved make Note :- PCC for foundation will be measured and paid separetly under relevent items
Supply and fixing Eros casting poles family of decorative cast iron post top arms made out cast iron including rovision for cable and hanging of LED light is to be provided complete all as specified and as directed. Make :- Havells- santra SINGLE side arm (Orbit Plus) or equivalent approved make.
Supply and installing LED 45 watt Aesthetically designed IP 66 LED post TOP with aluminium enclosure, powerd with high power LEDs as light source and die casheat sink exhibiting classic Victorian, with constant current electronic driver provided with high voltage, open & short circuit protection with suitable for operation on single phase AC supply: 220-240V, complete with all respects complete all as specified and as directed. Make :- Havells - Eros 45 W shallow bowl 3000k or equivalent approved make.
Supply and fixing bus bar box of suitable size but not less than 20 cm x 15 cm x 12 cm fabricated out of 2.0 mm thick CRCA sheet protected with seven tank phosphating process and powder coated to prevent from corrosion incuding 4 nos aluminium bus bar strip 25x3 mm over protection insulators with suitable nut bolts and washers including provision for outgoing and incomig cable and one no MCB SP 5 Amps and cable glands including necessary fixing clamps with nut bolt etc complete all as specified and as directed.
M&L for earthing complete with Galvanised steel earth plate eletrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised earth strip 32x6mm connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40 mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type C1 chamber, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of schedule Part-I complete all as specified and as directed.
M & L for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine and inserting GI pipe of 100 mm complete all as specified and as directed. Note :- Pipe will be measured and paid separately under relevant item.
M&L for light grade galvanized pipe ISI marked with all fitting ISI marked, laid in trenches, under road or fixing on wall/pole/ crossing nallah etc bore of pipe 100 mm complete all as specified and as directed .
Supply, installing, testing and commissioning of CPRI approved LT distribution panel board out door type of suitable size weather/vermin proof, made out of 3.15 mm thick CRCA sheet duly powder coated, mounted on 65 mm x 65 mm x 6 mm (ISA6565) iron angles frame of height 30 cm from PCC bedding, factory assembled compartmentalized construction, free standing type, including 3 phase and neutral 200 amps current carrying capacity copper bus bar with epoxy insulated coating with colour code and insulated support, cable galleries inter connecting bus bar connection/linkage complete and conforming to IS 8623 and IP 54 class of protection as per IS 2147 complete, including making connection of cables of incoming and outgoing with thimble/lugs, including the accessories as below complete and mounting the panel on ground/floor with PCC(1:3:6) bedding up to a height of 30 cm above ground level and 30 cm in foundation complete all as specified and as directed by Engineer-in-Charge.
a) Aluminium bus bar 400 amps for 3 phase & neutral -1 set
b) MCCB 4 pole 250 Amps 36 KA at 415 v -1 No ( incoming )
c) MCCB 4 pole 100 Amps 25 KA at 415 v -3 Nos ( Outgoing )
d) MCCB 4 pole 63 Amps 25 KA at 415 volts -7 Nos ( Outgoing)
e) MCB TPN 32A- 4 Nos
Taking down PCC pole of any height including disconnecting all electrical connection and taking down ACSR conductor and removing from site complete all as specified and as directed.
Supply, laying, jointing and testing in trenches, galvanized iron water tubing medium grade (ISI marked) including provision of all necessary steel fittings / accessories like tee, socket, union socket, elbow, reducer socket and nipple complete all as specified and as directed for the following sizes :-
(a) 40 mm (1 1/2”) dia
(b) 25 mm (1”) dia
(c) 20 mm (3/4”) dia
Supply and fixing Gun-metal, globe or gate valves, of following sizes with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed for the following sizes :-
(a) 40 mm (1 1/2”) dia
(b) 25 mm (1”) dia
( c) 20 mm (3/4”) dia
M & L for Drilling and tapping existing cast iron water mains of size 100 / 150mm (in position) for branch connections of the internal dia 25 MM includung clamp of 40 mm x 6 mm MS flat iron for support and necessary welding work if required complete all as specified and asdirected by Engineer-in-Charge.
M & L for cutting GI mains 50 mm dia, inserting of new GI TEE of size 50 mm x 50 mm x 40 mm for branch connection including excavation earthwork complete all as specified and as directed.
GUTHIKONDA BROTHERS
Dwarka Pershad Radhey Ramanlal
power links
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .