Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹2.4 CrAccepted-AOC | ₹2.4 Cr Quoted ₹1.3 Cr | l1 | Accepted-AOC l1 |
| 2 | l2₹2.4 Cr+₹1.1 Cr (86.9%)Rejected-AOC | ₹2.4 Cr+₹1.1 Cr (86.9%) | l2 | Rejected-AOC l2 |
Tender Value
Refer Docs
Closing Date
15 Mar 2024, 5:00 pmClosed
Head CCCF Chandrapur
CCCF Chandrapur
C2_Modular_OT/2024
2024_CHDPR_1022505_1
C2_Modular_OT/2024
Open Tender
Medical Equipments/Waste
Item Rate
112 days
CCCF Chandrapur
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
25 Jul 2024
1 Mar 2024
18 Mar 2024
1 Mar 2024
15 Mar 2024
1 Mar 2024
Amount
C2-Modular OT
Supply and Installation of SS 304 Puff Panel , Thickness: 50 MM. Front panel SS -304 wall thickness: 1.0 MM.Back panel material SS 304 ,wall thickness : 0.8 MM . Make- Jindal/ Tata Steel/ SAIL (As Per Technical Specification). Antimicrobial Coating: Filling of all Joints and cavities with metallic Epoxy Filler and Sanded Flush to provide a jointless finish.
OPTIONAL Quote for : Anti bacterial Epoxy and anti fungus sterile coating to be applied on the SS-304 finished walls and ceilling with at least 3-4 coat to achieve dry film thickness of minimum 200-300 Micron. The Primer will be supplied alongwith the paint should be imported one. the Anti bacterial and anti fungus coating should not peel off early and will have to be warranted by the vendor to last atleast 05 years. Make : SKK- Singapore, SIKA AG: Liquid plastic or equivalent one.
SITC Planair Ceiling System system constructed out of 1.6 MM Aluminium with extruded aluminium profile frame and sealed gasket.Size 2800 x 2400 MM having 08 numbers of H-14 grade HEPA filters. The HEPA filters having dust spot efficiency of 99.99% 0.03 micron. Air & Light diffuser made of mono filament precision woven polyester for the plan air ceiling to give a "LAMINAR FLOW" of filtered air as per Tender specifications. Make- Hindalco/ NALCO/JINDAL -
OPTIONAL : Planair Ceiling System system constructed out of 1.5 MM thick SS 304 1.0 MM thick sheet of size 2800 x 2400 MM having 08 numbers of H-14 grade HEPA filters. The HEPA filters having dust spot efficiency of 99.99% 0.03 micron. Air & Light diffuser made of mono filament precision woven polyester for the plan air ceiling to give a "LAMINAR FLOW" of filtered air as per Tender specifications.Make : TATA Steel / JINDAL/SAIL
SITC Surgeon Control Panel, Touch Screen 21 : The panel should contain features like Real time clock - HH:MM:SS format with day, Time Elapse day clock, peripheral light control system, OT light ON/OFF control system,Medical gas status (High/low/normal) with audible alarm for gases Oxygen,Nitrous Oxide, Vacuum,Medical Air 4 Bar and Surgical Air 7 Bar, Carbon Dioxide. Hand free telephone set with memory and should be compatible for Digital telephone system). Temperature and humidity Indicator with controller, HEPA filter status module, OT differentail pressure indicator system, Music control system with appropriate number of speakers as per OT area. As per Technical specification.( Note -GA dwg with sign stamp from OEM to be submit in techanical doc)
SITC Two Plate (Plate Size 14 " X 17 " ) LED X-Ray Viewing Screen designed to provide a high level of control luminance without flicker. (As Per Technical Specification)
SITC Peripheral lights LED lights with dimmable electronic Blast, size 300 MM x 600 MM (As Per Technical Specification).(MAKE-philips,wipro,with 5yr warnty next business day replacement )
SITC OT Main Door Automatic Sliding, hermetically sealing type of size 2100 (H) X 1800 mm (W) as per Tender specifications. Make-Metaflex/ Sonnemed / SonneMed / (As Per Technical Specification).
Radar hand switch (As Per Specification)
Foot Switch (As Per Technical Specification)
Storage Unit of size 1666 X 865 X 350 (Sizes in MM) (+/-5 %) Material- SS 304 having two shelves and made out of having 5 MM thick trqansparent toughned glass door in Aluminium Extruded frame and mounted flush with the theatre wall. (As Per Technical Specification )
Cascade Pressure Stabilizer having multi 304 graded stainless-steel blades to control room air pressure.
Writing Board (As Per Specification).
SITC Electrical wiring MS conduiting switch socket etc for each OT, conduits for integration TV monitor, Camera etc. (As Per Tender Specification).MAKE-Honeywell,polycab,kie,bec
SITC with robotic duct cleaning Aluminium Ducting work with Nitrile Rubber Thermal Insulation with aluminium foil ( 25mm for supply duct with damper +13mm for return duct) and Exhaust Return Grill with colar damper in Operating Rooms (As Per Specification) note -inside OT area only (Duct gauage as PER ISHRAE/ASHRAE/SMANCA standard )
SITC Medical Gas Line Inside the OT for O2, N2O, Air-4/7, Vac, CO2 & AGSS (As Per Specification) with suitable connector/adaptor to connect Pendant
Viewing Window - Size 2000 MM (H) X 1000 MM (W). The view window should be double insulated fixed glazing not less than 5 MM thick toughened safe glass with Motorized venetian blinds size as per drawing. (As Per Technical Specification)
SITC WALL MOUNTED LED/IPS FLAT SCREEN DISPLAY 55 "- (24X7),having facility for education and digital signage facility As per Technical specification.(make- SAMSUNG,LG)
SITC WORK STATION/ CPU Cabinet should have shelf keyboard CPU cabin (As Per Technical Specification) Intel i5/ 12th Gen/16 GB/ 1TB SSD/USB Keyboard and Mouse from same OEM/ 23.8"Display/ Windows 11/MS Office 2021 Life time/3 Year onsite Warranty,with intel UHD graphic (MAKE-HP,Dell)
Isolation Panel (For OT) Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of 12KVA Medical Isolation Panel for OT's fabricated out of 16 gauge CRCA sheet steel incubicle compartmentalized wall mounted, dust and vermin proof as per IEC61439 with glazed door. OT panel board shoud include insulation and ground fault monitoring device. As per IEC 60364-7-710 & Protection from electromagnetic disturbances, in accordance with IEC 60364-4-44 and IEC 61000-6-2 and -3. 1 No. TRANSFORMER 12kVA Type Tested IEC 61558 1 No. Insulation Monitoring Device and ground fault monitoring 1 No. Audible and visual alarm Device for an insulation or electrical fault TNS Earthing Zone 4 Nos. 16A 2P 10KA MCB's. 4 Nos. 16A 2P 30ma RCCB's. IT Earthing Zone 12 Nos. 16A 2P 10KA MCB's. 12 Nos. Sensors/CT's 1 Nos. Insulation Fault detectors (12 channel) Ground Fault Detection 12 (channel) Note: All RCCB shall be of SI-type. All MCB’s shall be minimum of 10 KA breaking capacity & ‘D’ curve only. All incoming and outgoing feeders cubical shall be 100% segregated/ isolated. Isolation Panel (vendor should submit sign stamp GA dwg along with BOM of OEM ,as per MAKELIST ) other wise it will consider as invalid submission (For OT) described as above
Isolation Panel (For PROCEDURE ROOM) Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of 10KVA Medical Isolation Panel for OT's fabricated out of 16 gauge CRCA sheet steel incubicle compartmentalized wall mounted, dust and vermin proof as per IEC61439 with glazed door. OT panel board shoud include insulation monitoring device. As per IEC 60364-7-710 & Protection from electromagnetic disturbances, in accordance with IEC 60364-4-44 and IEC 61000-6-2 and -3. 1 No. TRANSFORMER 10kVA Type Tested IEC 61558 1 No. Insulation Monitoring Device 1 No. Audible and visual alarm Device for an insulation or electrical fault TNS Earthing Zone 4 Nos. 16A 2P 10KA MCB's. 4 Nos. 16A 2P 30ma RCCB's. IT Earthing Zone 12 Nos. 16A 2P 10KA MCB's. 12 Nos. Sensors/CT's 1 Nos. Insulation Fault detectors (12 channel) Note: All RCCB shall be of SI-type. All MCB’s shall be minimum of 10 KA breaking capacity & ‘D’ curve only. All incoming and outgoing feeders cubical shall be 100% segregated/ isolated. Isolation Panel(vendor should submit sign stamp GA dwg, along with BOM of OEM ,as per MAKELIST ) other wise it will consider as invalid submission (For PROCEDURE ROOM) described as above
HEPA Filters
Peripheral Light
Door Handle
Blast
Door Gasket
Modular Concepts
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .