Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.4 LAccepted-AOC C O RANJIT ELECTRICAL KEATING ROAD SHILLONG 793001 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793001 | L1 | Accepted-AOC BID OF M/S MANOJ KUMAR BAL IS HEREBY ACCEPTED BEING L1 BIDDER. | |
| 2 | L2₹47.4 L+₹1.8 L (3.92%)Rejected-Finance | L2 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER | |
| 3 | L3₹49.9 L+₹4.4 L (9.60%)Rejected-Finance | L3 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER | |
| 4 | L4₹50.9 L+₹5.3 L (11.7%)Rejected-Finance LUM KHARKONGOR NEAR EFCI HEBRON LOCAL CHURCH PDENGSHONG BLOCK D MADANRITING EAST KHASI HILLS 793002 | SHILLONG | EAST KHASI HILLS | MEGHALAYA | 793002 | L4 | Rejected-Finance REJECTED BEING OTHER THAN L1 BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 Jul 2024, 6:00 pmClosed
GE SHILLONG
GE SHILLONG SHILLONG PIN 793002
REPAIR / REPLACEMENT OF SEWAGE SYSTEM INCLUDING CLEANING OF SEWAGE LINES MANHOLES SEPTIC TANKS SOAK WELL ETC AT 58 GTC AT HAPPY VALLEY AND REPAIR TO FENCING/ COMPOUND WALL AND BUILDING FOR MES PUMP HOUSE AND SUB STATION AT HAPPY VALLEY UNDER GE SHILL
2024_MES_660280_1
GE/SHL/TOKEN-43 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
GE SHILLONG
ALL AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
GE SHILLONG
₹90,000
31 Aug 2024
18 Jun 2024
17 Jul 2024
18 Jun 2024
16 Jul 2024
2 Jul 2024
Amount
M&L for water proofing treatment to RCC roof slab/sunken floor, including parapet comprising with the following courses of treatment/specification from bottom to top:- (i) Taking out old roof treatment and roughening the same old concrete slab by picking, sweeping clean and washing down with water to remove dust etc.and applying cement slurry @3kg/Sqm (ii) Screed bed or bedding layer of mortar 1:4 in 15 mm thick for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items) (iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986. (iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be less applied over bituminous primer as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction. (v) Applying one coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm.
Refixing only 0.63 mm thick galvanized corrugated iron (CGI) sheeting with two corrugation side lap sheets having zinc coating @ 120 gram per sqm inclusive of both sides, fixed with coach screws and washers as in roof covering etc. including dismantling any gauge, thickness, including Nainital or similar pattern roof cverings complete all as specified and directed.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as including dismantling corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof cverings complete all as specified and directed.
S & F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as including dismantling plain steel sheeting any gauge, thickness, including Nainital or similar pattern roof cverings complete all as specified and directed.
S & F 500 litres capacity double layer, rotational molded, polythene (white colour), tripple layer water storage tank, ISI Marked (Cylindrical vertical with closed top),colour white , hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including dismantling completeall as specified and as directed. Make : Sintex, Polycon, waterwell.
S&F in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and as directed.
Supply and fix 15 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line including concealed in wall all as and including taking down up or down complete all as specified and directed.
Supply and fix 20 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line including concealed in wall all as and including taking down up or down complete all as specified and directed.
Refixing 15 mm bore old steel tubing but with new GI fittings after cleaning the pipe, in new or old position ( wall, ceiling or floor) including taking up or down complete all as specified and directed.
Refixing 20 mm bore old steel tubing but with new GI fittings after cleaning the pipe, in new or old position ( wall, ceiling or floor) including taking up or down complete all as specified and directed.
S&F in repair 15mm bore stop cock cast copper alloy, fancy type, chromium plated, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed.
S & F in repair 15 mm bore CP fancy type bib tap long body cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified.
S&F as in repairs.Vitreous China wash down water down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete.
S & F in repair PVC (Plastic polymer Cistern) valve less, Syphonic action type, flushing cistern of capacity 10 litres, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete all as directed by Engineer-in-Charge
S&F in repair Stainless steel sink with draning board, made out of 1.00 mm thick sheet with waste fitting, cast iron cantilever brackets, connecting union overall size 915 mm x 460 mm with bowl size 410 mm x 330 mm x 160mm complete all as specified and directed by Engineer in Charge.(Make : Bluestar,Nirali or equivalent.)
S&F in repair for 20mm dia Ball cock valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 2 0 m m - 2 1 0 g m s ) complete all as specified and directed. Make: Prayag or Equivalant.
Supply and fix in repair 15mm bore fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed. .
S&F in repairs Bib taps of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight15mm-110gms) complete all as specified and directed. .
M&L for PCC 1:3:6 type C2 (using 40mm graded agg) as in sub base including demolition of plain cement concrete (unreinforced) in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed.
S&F in repair for Grating doom 100 mm dia of PTMT (minimum weight 25gms) complete all as specified and directed.
S & F in repairs 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
S & F in repairs 600 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
Fixing only chain link fencing including, line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc, including provision of binding wire etc. including dismantling fencing wire mesh, any type complete all as specified.
Supply only chain link fencing any size or type exc 4kg per sqm complete all as specified.
Dismantling posts or struts (Wood, steel or RCC) any section, including taking out embedded portion from concrete, brick work, masonry etc., and making good disturbed in natural ground complete all as specified and as directed.
S & F Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors and gate repair works, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-500D complete all as specified.
M & L for PCC 1:3:6 , Type C2 (40mm gradd stone aggregate) as in fixing of RCC/PCC post or similar type of works etc complete all as specified and directed by Eng-in-charge.
Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and dircted.
M & L Flat/angle iron iron fixed to posts to hold the chain link fencing complete all as specified and directed
M & L 10 mm dia round bars as holding bars for chain link fencing fixed at top and bottem, including linking one to another horigontal bar complete all as specified and directed.
S&F MS 10 to 12mm dia screw bolts (Machine made) with hexagonal or square heads at one end and screwed the other ends each screwed end to be fitted with washers and one hexagonal or square nut exc 15 cm n.exc 22.5 cm long complete all as specified and directed
S&F Steel rolling shutters of lath thickness 1.00mm, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer erected in position as indicated, complete gear operated type with bevel gear box and crank handle complete all as specified and directed
M&L for preparation of new surfaces of steel n. exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
M&L for Cutting holes into or through brick walls built in cement mortar and stone walls built in cement mortar or cement lime mortar and walls of cement concrete, and also making good in cement concrete 1:2:4 type B-1 as required (superficial area n exc 150sqcm) complete all as specified.
S&F in repair galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining, fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provisioning of galvanised mild steel wire, staples of steel pins etc all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed.
M&L Glazed ceramic colour tiles of size 350 x 250 x 7mm thick in vertical wall/ pumphouse filter bed etc set and jointed with neat cement slurry and pointed in white or colour cement to match with the colour of tile over and including 10 mm thick backing course in cement sand mortar 1:4 complete as specified and directed.
M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and as directed.
M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors/filter bed area, dado , skirting and riser etc, set and jointed in cement slurry and pointed in white or colour cement to match over and including 10 mm thick backing course in cement sand mortar 1:4 complete all as specified and directed
M&L Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in eat cement slurry in floors with grey pigments cement and pigments and including 15 mm thick screed bed in cement sand mortar 1:6 complete all as specified and as directed.
Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MD land all specified and directed.
M&L for rendering 10 mm thick on concrete surface in cement mortar (1:6) as backing coat and 5 mm th in CM 1:6 using finishing the surface even and smooth without using extra cement complete all as specified and as directed.
M & L for preparation of new plastered surfaces and applying two coat of white wash on the surfaces of walls complete all as specified and directed by Engr-in-Charge.
M&L for Cement concrete nominal mix of 1:1.5:3 type A1 (using 20mm graded aggregate) as in in foundations, filling and mass concrete complete all as specified and as directed.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for rendering 10 mm thick on concrete surface in cement mortar (1:6) as backing coat and 5 mm th in CM 1:4 using finishing the surface even and smooth without using extra cement, including mixing only liquid water proofing compound as per manufacturer instruction complete all as specified and as directed on External surface. Note:- WPC will be measured & Paid separately
M&L for 10mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and as directed.
M & L for rendering 05 mm thick in CM 1:3 on ceiling surfaces of cement concrete and finished the surface even and smooth without using extra cement complete all as specified & directed .
Supply only for water proofing compound.
M & L for preparation of new plastered/concrete surfaces of ceiling, applying three coat of white wash on the surfaces of ceiling complete all as specified and directed by Engr-in-Charge.
M&L for preparation of old painted of steel or iron surfaces of any description not otherwise described over 10cm width or girth and applying one coat of Synthetic enamel paint complete all as specified.
S & F of 2nd class hard wood scantling, clean sawn in any position and any description as in unframed work including dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed workcomplete all as specified and directed.
M&L for 4mm thick Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with nails as in ceiling including dismantling wall & ceiling boards of any description including cover fillets complete all as specified and directed.
Dismantling timber scantling in fillets, rails, posts, rafters/purlins under 40 sqcm in section complete all as specified and directed.
S&F 2nd class HW plain fillets square rectangular triangular in section, clean sawn secured with nails section area exc. 13 sqcm but n.exc 25 sqcm
S&F 2nd class HW plain fillets square rectangular triangular in section, clean sawn secured with nails sectiona area exc 6 sqcm & n.exc 13 sqcm complete all as specified and directed..
M&L for preparation of surfaces of wood and wood based materials new or old of any description and girth not otherwise described and treated with two coats of creosite oil complete.
M&L for preparation of surfaces of any description n.exc 10 cm width/girth not otherwise descibed & apply two coats of Synthetic Enamel paint over a coat of pink primer wooden surface complete all as specified and directed.
Taking down chowkhats or frame with shutter without taking off shutter from the frame exc 1.50 sqm but not exc 4 sqm each & removing from site complete all as specified and directed.
Taking down chowkhats or frame with shutter without taking off shutter from the frame not exc 1.50 sqm & removing from site complete all as specified and directed.
Taking down shutter of any description n.exc 1 Sqm each complete all as specified and directed.
Taking down shutter of any description exc 1 Sqm but not exc 2.00 sqm each complete all as specified and directed.
Supply and fixing 2nd class HW plain solid straight chowkhats/frame wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
Supply and fixing 2nd class HW 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares (without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats.
Supply and fixing 2nd class HW 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares (without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
Supply and fixing Flush shutters, solid core construction 35 mm thick with block board core and plywood face panels, commercial type on both sides conforming to IS-2202(Part-I), 1983 complete all as specified and directed.
Supply and fixing 2nd class HW 35mm thick plain framed panelled shutters (any number of panels), with panel of timber flats on both sides or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats.
Supply and fixing solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube all as specified.
Supply and fix Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes all around . M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, all as specified.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Supply and fixing 100mm size butt hinges cold rolled medium weight, ISI marked complete all as specified and directed.
Supply and fixing 200mm size MS barrel tower bolt stone enamelled black with bright bolt ISI marked complete all as specified and directed.
Supply and fixing in repair 200mm sizeAluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
Supply and fixing in repair 125mm size aluminium anodised cast type,complete all as specified and directed.
Supply and fixing 150mm size MS pressed handle oval type stove enameled block complete all as specified and directed.
Supply and fixing 250mm long MS sliding door bolt, plate type, stove enameled black with bright bolt not less than 12mm dia with and including a min of siz bolt & nuts four on bolt & two on staple,ISI marked, complete all as specified and directed.
Supply and fixing 75mm size butt hinges cold rolled medium weight ISI marked complete all as specified and directed.
Supply and fixing 150mm size MS barrel tower bolt stone enamelled black with bright bolt ISI marked complete all as specified and directed.
Supply and fixing 100mm size MS pressed handle oval type stove enameled block complete all as specified and directed.
S&F in repairs Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames, glazed with putty or fixed with beads complete all as specified and as directed.
S&F in repair Sheet glass 3 mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed.
S&F in repair one side frosted glass 3 mm thick, glazing with oil putty in square n.exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed.
S&F in repair Sheet glass 4.80 mm thick, ordinary quality and glazing with oil putty in square exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed.
Removal of plant/vegetation/bushes growth etc froom roof or parapet of building including removing of root and making good disturbed surface with cement mortar 1:3 including mixing only liquid waterproofing compound as per manufacturer instruction complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 M in depth as in foundation in soft or loose soil and getting out complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 M in depth as in foundation in hard/dense soil and getting out complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick in soft/loose soil complete all as specified and directed.
Removing of surplus excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point in soft soil complete all as specified and directed.
M&L for salt glazed stone ware drain pipes 200 mm bore grade ‘A’ laid in trenches and jointed in cement mortar (1:1) including cement concrete (1:4:8) type D-2 (using 40 mm grade stone aggrete) as in concrete bed to drain pipes, packing under & haunching against the sides of pipes after they are laid & tested including demolition and breaking up old drain pipes 200 mm dia (salt glazed stone ware, AC or reinforced concrete) pipe set in cement mortar and removing from site of work to a distance n exc 50mtrcomplete all as specified and as directed.
M&L for salt glazed stone ware drain pipes 150 mm bore grade ‘A’ laid in trenches and jointed in cement mortar (1:1) including cement concrete (1:4:8) type D-2 (using 40 mm grade stone aggrete) as in concrete bed to drain pipes, packing under & haunching against the sides of pipes after they are laid & tested including demolition and breaking up old drain pipes 150 mm dia (salt glazed stone ware, AC or reinforced concrete) pipe set in cement mortar and removing from site of work to a distance n exc 50mtrcomplete all as specified and as directed.
M&L for salt glazed stone ware drain pipes 100 mm bore grade ‘A’ laid in trenches and jointed in cement mortar (1:1) including cement concrete (1:4:8) type D-2 (using 40 mm grade stone aggrete) as in concrete bed to drain pipes, packing under & haunching against the sides of pipes after they are laid & tested including demolition and breaking up old drain pipes 100 mm dia (salt glazed stone ware, AC or reinforced concrete) pipe set in cement mortar and removing from site of work to a distance n exc 50 mtr complete all as specified and as directed.
Cleaning of sewage lines using split Bamboo with a gunny bag piece tied with bamboo with binding wire and inserting the bamboo in sewage lines through manhole/ gully trap clear flow of sewage is observed of 100/150/200 mm bore pipe complete all as directed by Engr-in-charge at site.
Taking out and removing sludge water/waste materials/foreign materials from septic tank of any size and burring the entire sludge under ground in the pit of suitable size and covering the pit with earth or earth mixed rubbish and removing surplus soil to a distance n.exc 50 m including necessary earth work in pit complete all as directed by Engr-in-Charge.
Cleaning of blocked water closet by flushing with water and cleaning of soil pipe upto first manhole, cleaning WC Pan/Floor trap/Nahani Trap of bathroom, kitchen/urinals and flushing cistern with water complete all as directed by Eng-in-charge.
Cleaning of manholes with spades or bucket taking out sludge from manhole and disposed off aside by putting earth on it. Again use water with bucket and put in manhole to clear the sludge and ensure the sludge is drain out completely. The depth of manhole n.exc 1 mtr each.
All as per item No 115 here-in-before but depth of manhole exc 1mtr but n.exc 2mtr.
S&F in repair 110mm PVC (SWR) pipe single socket in any length with rubber ring jointed fixed to wall with clamps (ISI Mark) including taking down old unserviceable pipes complete all as specified and as directed.
S&F in repair PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) branch piece single (Y) equal or unequal.
All as per item No 110 but with access door
S&F in repair 110mm bore PVC (SWR) bends / door bend with acess door.
S&F in repair 75mm bore PVC (SWR) bends / door bend with acess door.
S&F in repair 110mm bore PVC (SWR) junction single (single T) equal or unequalwith acess door.
S&F in repair 75mm bore PVC (SWR) junction single (single T) equal or unequalwith acess door.
S&F in repair 110mm PVC (SWR) vent cowl.
S&F in repair 75mm PVC (SWR) vent cowl.
S&F in repair 110mm bore PVC (SWR) reducers.
S&F PVC gutter , Half Round, 180mm size complete all as specified and directed.
S&F in repairs Joint Bracket (with 2 clamps), 180mm for PVC pipes (half round) complete all as specified and directed.
S&F in repairs Support Bracket, 180mm for PVC pipes (half round) complete all as specified and directed.
S&F in repairs Running Outlet (with 2 clamps), 180mm for PVC pipes (half round) complete all as specified and directed.
S&F in repairs Stop End Outlet (with 1 clamp), 180mm for PVC pipes (half round) complete all as specified and directed.
S&F in repairs PVC Reducer, 180mmx110mm complete all as specified and directed.
S&F in repair Salt-glazed stoneware gully traps, square or round mouthed, tvpe of size 150 x 100 mm complete all as specified & directed.
S & F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all specified and as directed.
Demolition of cement concrete (reinforced) as in cover slabs of any description and in any position not otherwise provided for and Including removal of debries out side MoD land complete all as directed by the Engr-in-charge.
M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for soakage well / manhole and similar works supported on walls set in cement mortar 1:6 complete. Note:- Reinforcement steel will be measured & paid sepratly.
M&L for TMT bars 10 mm dia cut to length bent to shape etc as required and binding with and including MS wire (annealed) not les than 0.9 mm dia as in reinforcement complete all as specified and as directed.
Dismantling of stone slabs and granite laid, bedded and pointed in any mortar of any description or thickness in floors, aprons cills or plateform etc all as specified and directed.
M & L for Machine pressed precast concrete interlocking paver block of approved shape and size 60mm thickness, with minimum compressive strength of 60 N/Sqmm (M-35Grade) without correcting factor for chamfering , made in rubber moulds with 0.5mm thick scratch proof lacquer coating on top surface, with white cement and pigment confirming to IS 15658-2006 complete all as specified and directed.
Demolition of plain cement concrete (unreinforced) in ground floors and pavings nexc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregate as in foundation.
M &L for 75mm thick PCC (1:3:6) type B2 as in flooring of septic tank, manhole etc with 40mm graded aggregae finishing cement concrete surface even and smooth using extrra cment complete all as specified and directed.
M&L for 75 mm thick PCC 1:3:6 type C1 using 20 mm graded stone aggregate as in plinth protection, including finishing the surface even and fair complete all as specified and as directed.
M&L for 75mm thick PCC 1:2:4 type B2 (using 40mm graded agg) as in path incl finishing even & smooth without using extra cement complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded aggregate) as in surface channels and drains including necessary formwork
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc
M&L for PCC (1:2:4) type B0 as in benching & coping with 12.50mm graded aggregate incl necessary form work moulds all as specified and as directed.
M&L Precast PCC (1:3:6) type C1 (using 20mm graded agg) solid block masonry exc 10cm in width or girth and setting CM (1:6) including demolition of Precast cement concrete block walling in any position and Including removal of debries out side MoD land complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar (1:4) and finish even and fair without using extra cement including taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MD land all specified and directed.
Demolition of plain cement concrete (unreinforced) Concrete of any description and in any position not otherwise specifically provided for complete all as specified and as directed.
M&L for PCC (1:5:10) type E2 (using 40mm graded agg) as in sub base of WC complete all as specified and as directed.
S & F in repair Vitreous china squatting pan of pattern Orissa Pattern of size 580x 440 mm white with 110mm bore PVC ‘P’ or ‘S’ trap , front or back inlet but excluding flushing cistern and flush pipe including placing in position in floor and embedded in cushion of PCC type E2 ( 1:5:10, using 40 mm graded stone aggregates), and finishing the top surfaces to match with the existing flooring as in repairs.
S&F in repairs plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete.
S & F in repairs to 600mm long PVC Waste pipe to WHB/urinals/Sink complete all as specified and as directed.
S&F in repairs PVC flush pipe of low or high density 32mm dia including jointing and fixing complete.
M/S SAMAL CONSTRUCTION
M/S U.K ENTERPRISE
M/S Thapa Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .