Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.0 LAdmitted-Finance 202 1ST FLOOR VIVEKANAND PURI MALKAGANJ SARAI ROHILLA NORTH DELHI DELHI 110007 UDYAM DL 01 0065084 | NORTH DELHI | DELHI | 110007 | L1 | Admitted-Finance | |
| 2 | L2₹6.5 L+₹45,288.40 (7.55%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹6.5 L+₹51,566 (8.59%)Admitted-Finance | L3 | Admitted-Finance | |
| 4 | L4₹6.7 L+₹72,784.76 (12.1%)Admitted-Finance 1008 A PREMIER ENGINEERING COMPANY PURVI RITHANI MEERUT DELHI ROAD MEERUT UTTAR PRADESH 250103 INDIA | MEERUT | UTTAR PRADESH | 250103 | L4 | Admitted-Finance | |
| 5 | L5₹6.9 L+₹88,972 (14.8%)Admitted-Finance 4264 GALI SHAHTARA AJMERI GATE DELHI DELHI 110006 | NORTH DELHI | DELHI | 110006 | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Premier Engineering Company L4 | Super System Engineers L6 | Raj Engineering Co. L2 | HYDROCON ENGINEERS | HYDROCON ENGINEERS L8 | paramount systems L5 | MITTAL TRADING COMPANY L1 | INNOVATIVE ENGINEERS L7 | Tushar Engineers L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.01 | - Supply / Fabrication of LT Panel Board cubical type, floor mounting, dust & vermin preventing construction, of the minimum size 1500 X 1500 X 350 mm, suitable for indoor fixing, made out of 16 SWG CRCA sheet (frame of 14 SWG), with provisions for cable entry from bottom and having chambers as-two incomer chambers (one each for the changeover and incomer MCCB), one metering chamber for the main incomer MCCB, two outgoing chambers for outgoing MCCB,, one outgoing chamber for two nos. of lighting MCBs. The panel should have separate cable alleys and bus bar alleys. It should be suitable for operation and maintenance from the front and having removable covers at the back and having doors complete with locks etc. at the front for each chamber. The rating of main bus bars has to be 300 Ampere for three phases and half for the neutral in Aluminium construction duly sleeved with phase indicating heat shrinkable Sleeves. It should be complete in all respect along with painted through powder coating process and with complete provisions suitable for all the switchgears as below to be fitted / installed properly so as to make two incomers, one main metering module, one for lighting supply, two star delta starters with complete mounting accessories as per requirement with complete internal connections of switchgears and control gears with the main bus bars in the Panel through copper cable or bus bars along with Making all the required wiring connections for all measuring and indicating instruments with all the accessories, thimbles, ferrules etc. complete in all respect as per requirement. | 2 | Job | 10,000 ₹11,800 Lowest | 1,30,000 ₹1,53,400 | 1,06,000 ₹1,25,080 | 2,16,000 ₹2,54,880 | 2,16,000 ₹2,54,880 | 1,00,000 ₹1,18,000 | 82,000 ₹96,760 | 1,96,000 ₹2,31,280 | 1,50,000 ₹1,77,000 |
| 1.02 | S/o Changeover, Switch, 250 Amp, 4 Pole, 415V AC. Make:-L&T/Schneider/HPL | 2 | Nos. | 27,988 ₹33,025.84 | 10,200 ₹12,036 Lowest | 22,000 ₹25,960 | 45,000 ₹53,100 | 45,000 ₹53,100 | 30,000 ₹35,400 | 40,000 ₹47,200 | 40,000 ₹47,200 | 26,000 ₹30,680 |
| 1.03 | 3. S/o Moulded Case Circuit Breaker (MCCB) of rating 250 Amp, Triple Pole, 415V, AC of breaking capacity of 50 KA or more. Make:-L&T/Schneider/BCH/C&S | 2 | Nos. | 29,600 ₹34,928 | 20,400 ₹24,072 | 22,000 ₹25,960 | 23,000 ₹27,140 | 23,000 ₹27,140 | 30,000 ₹35,400 | 40,000 ₹47,200 | 20,000 ₹23,600 Lowest | 28,000 ₹33,040 |
| 1.04 | S/o Moulded Case Circuit Breaker (MCCB) of rating 125 Amp, Triple pole, 415 V, AC of breaking capacity of 36 KA or more. Make:-L&T/Schneider/BCH/C&S | 4 | Nos. | 39,120 ₹46,161.6 | 30,000 ₹35,400 | 19,600 ₹23,128 Lowest | 38,000 ₹44,840 | 38,000 ₹44,840 | 20,000 ₹23,600 | 40,000 ₹47,200 | 24,000 ₹28,320 | 24,000 ₹28,320 |
| 1.05 | S/O Motor protection Relay MPR 300 32-88 AMP Make:-L&T/Schneider/BCH/C&S | 2 | Nos. | 15,960 ₹18,832.8 | 44,000 ₹51,920 | 9,400 ₹11,092 Lowest | 11,000 ₹12,980 | 11,000 ₹12,980 | 10,000 ₹11,800 | 10,000 ₹11,800 | 20,000 ₹23,600 | 14,000 ₹16,520 |
| 1.06 | S/o overload Relay for 40-60 Amp MN 5 Make:-L&T/Schneider/BCH/C&S | 4 | Nos. | 13,364 ₹15,769.52 | 15,400 ₹18,172 | 17,200 ₹20,296 | 14,000 ₹16,520 | 14,000 ₹16,520 | 10,000 ₹11,800 Lowest | 20,000 ₹23,600 | 16,000 ₹18,880 | 13,600 ₹16,048 |
| 1.07 | S/o Single Phase Preventer Make:-L&T/Schneider/BCH/C&S | 4 | Nos. | 3,360 ₹3,964.8 | 5,200 ₹6,136 | 2,600 ₹3,068 Lowest | 10,000 ₹11,800 | 10,000 ₹11,800 | 10,000 ₹11,800 | 4,000 ₹4,720 | 6,000 ₹7,080 | 4,000 ₹4,720 |
| 1.08 | S/o Ampere Meter Digital type. Make:-L&T/Schneider/AE | 6 | Nos. | 4,920 ₹5,805.6 Lowest | 5,100 ₹6,018 | 5,280 ₹6,230.4 | 12,000 ₹14,160 | 12,000 ₹14,160 | 15,000 ₹17,700 | 6,000 ₹7,080 | 7,200 ₹8,496 | 6,000 ₹7,080 |
| 1.09 | S/o Volt Meter Digital type. Make:-L&T/Schneider/AE | 2 | Nos. | 1,640 ₹1,935.2 Lowest | 1,700 ₹2,006 | 1,760 ₹2,076.8 | 4,000 ₹4,720 | 4,000 ₹4,720 | 5,000 ₹5,900 | 2,000 ₹2,360 | 2,400 ₹2,832 | 2,000 ₹2,360 |
| 1.10 | S/o Ampere Meter selector switch. Make:-L&T/Schneider/BCH/C&S | 6 | Nos. | 1,590 ₹1,876.2 | 6,120 ₹7,221.6 | 1,920 ₹2,265.6 | 12,000 ₹14,160 | 12,000 ₹14,160 | 15,000 ₹17,700 | 3,000 ₹3,540 | 2,400 ₹2,832 | 1,200 ₹1,416 Lowest |
Tender Value
Refer Docs
EMD Value
₹18,900
Closing Date
15 Sept 2025, 11:15 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE ENM M III
Delhi Jal Board C-Block Near Divya Jyoti Apartment, Sector-19 BPS Rohini, Delhi-89
Replacement of 415 V panel upto 40 HP at Pump house no 1 and platinum apartment sector 18 BPS ward no 54 Rohini D under Rohini constituency AC 13
2025_DJB_277856_28
NIT No. 10 (2025-26)M-III
Open Tender
Miscellaneous Works
Item Rate
30 days
EE ENM M III
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Account No SB 50448339804
₹18,900
Yes
23 Sept 2025
8 Sept 2025
15 Sept 2025
8 Sept 2025
15 Sept 2025
8 Sept 2025
- Supply / Fabrication of LT Panel Board cubical type, floor mounting, dust & vermin preventing construction, of the minimum size 1500 X 1500 X 350 mm, suitable for indoor fixing, made out of 16 SWG CRCA sheet (frame of 14 SWG), with provisions for cable entry from bottom and having chambers as-two incomer chambers (one each for the changeover and incomer MCCB), one metering chamber for the main incomer MCCB, two outgoing chambers for outgoing MCCB,, one outgoing chamber for two nos. of lighting MCBs. The panel should have separate cable alleys and bus bar alleys. It should be suitable for operation and maintenance from the front and having removable covers at the back and having doors complete with locks etc. at the front for each chamber. The rating of main bus bars has to be 300 Ampere for three phases and half for the neutral in Aluminium construction duly sleeved with phase indicating heat shrinkable Sleeves. It should be complete in all respect along with painted through powder coating process and with complete provisions suitable for all the switchgears as below to be fitted / installed properly so as to make two incomers, one main metering module, one for lighting supply, two star delta starters with complete mounting accessories as per requirement with complete internal connections of switchgears and control gears with the main bus bars in the Panel through copper cable or bus bars along with Making all the required wiring connections for all measuring and indicating instruments with all the accessories, thimbles, ferrules etc. complete in all respect as per requirement.
S/o Changeover, Switch, 250 Amp, 4 Pole, 415V AC. Make:-L&T/Schneider/HPL
3. S/o Moulded Case Circuit Breaker (MCCB) of rating 250 Amp, Triple Pole, 415V, AC of breaking capacity of 50 KA or more. Make:-L&T/Schneider/BCH/C&S
S/o Moulded Case Circuit Breaker (MCCB) of rating 125 Amp, Triple pole, 415 V, AC of breaking capacity of 36 KA or more. Make:-L&T/Schneider/BCH/C&S
S/O Motor protection Relay MPR 300 32-88 AMP Make:-L&T/Schneider/BCH/C&S
S/o overload Relay for 40-60 Amp MN 5 Make:-L&T/Schneider/BCH/C&S
S/o Single Phase Preventer Make:-L&T/Schneider/BCH/C&S
S/o Ampere Meter Digital type. Make:-L&T/Schneider/AE
S/o Volt Meter Digital type. Make:-L&T/Schneider/AE
S/o Indicating Lamp, Led type Make:-L&T/Schneider/BCH/C&S
S/o MCB, 63 Amps, TP, 'C' Curve. Make:-L&T/Schneider/BCH/C&S
S/o Current Transformer 100/5 ampere. Make:-AE/Kuppa / Matrix
S/o Current Transformer 200/5 ampere. Make:-AE/ Kuppa / Matrix
Other material required like insulators, heat shrinkable sleeve, bakelite, nuts & bolts, aluminum thimbles, ferrules, rubber packing etc. as required.
Supply of Manually operated oil immersed sheet steel clad wall mounting star - Auto Transformer starter fitted with 1 No. Under voltage release, 3 Nos. Magnatic Overload Release with Oil Dashpot time lags, stop leaver, plain enteries for PVC cables suitable for Squirrel case induction motor 415 V, 3 Phase, 50 Hz, 40 HP Heavy Duty Make: - Advance, Bentax or any approved in DJB
8. Supply of Oil immersed automatic push button operated sheet steel clay mounting direct on line starter 415 volt 50 Hz, three phase 7.5 HP
Dismantling of old panel board / starters etc. and disconnecting all the old incoming and the outgoing connection and shifting the panel / starters from the site.
S/O PVC insulated Single core Unsheathed industrial flexible cable confirming to IS 694: 1990 with flexible bright annealed copper conductor for voltage grade up to 1100 volt 16 sq mm Make: - Gloster, Grandlay, Finolax, Polycab, Havells & Aproved in DJB SOR 43.1.6
4x35 sq. mm, PVC insulated & PVC sheathed Aluminum armored conductor cable confirming to IS: 1554 (Part-i) complete as required. Make: Make: Gloster, Grandlay, Havells, Plaza, ICC, ICL, Universal & CCI. SOR 18.6.6
Fixing of new base frame at the site with the help of fasteners / welding and grouting of nut bolts and including all other work as per site requirements and Fixing the new LT Panel at the newly fixed base frame by lifting the panel board and placing it at the base frame properly and fixing it to the frame by nut bolts as requirement. Fabrication and supply of base frame made out of Angle Iron of suitable size for fixing the above Panel and suitable for making outgoing/incoming cable entries in the panel. It should be duly painted and ready with provisions for installing at the site.
Making the incoming connections to the Panel by connecting the existing cables after proper thimbling etc. including providing & fixing of consumables as per requirement. Making the outgoing connections of starters by Connecting outgoing starters to their respective pumps etc. Through existing cables as per site requirement after relaying of the cables as required, proper thimbling and tapping etc. including providing & fixing of material as per requirement. Making the outgoing connections of lighting DB by Connecting outgoing MCBs to the DBs etc. through the existing cables as per site requirement after relaying of the cables as required, proper thimbling and tapping etc. including providing & fixing of material as per site requirement.
Testing and Commissioning of the Panel Board first at NO LOAD and then at ON LOAD and Operations as per the satisfaction of engineer in charge. Loading, Unloading, Cartage and Transportation charges for the above Panel up to the site including charges of heavy labour etc.
Raj Engineering Co. (BID ID -1619712)
Tushar Engineers (BID ID -1619859)
Premier Engineering Company (BID ID -1619623)
paramount systems (BID ID -1619933)
Super System Engineers (BID ID -1619654)
INNOVATIVE ENGINEERS (BID ID -1619735)
HYDROCON ENGINEERS (BID ID -1619758)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .