Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.4 CrAccepted-AOC 00 00 NAPASAR ROAD NENO KA BASS BIKANER RAJASTHAN BIKANER RAJASTHAN 334022 UDYAM RJ 08 0001676 | BIKANER | RAJASTHAN | 334022 | ₹5.4 Cr Quoted ₹5.7 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹5.7 Cr+₹76,180.35 (0.13%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹5.7 Cr+₹76,180.35 (0.13%) | L2 | Rejected-Finance L2 |
| 3 | L3₹6.0 Cr+₹31.9 L (5.56%)Rejected-Finance | ₹6.0 Cr+₹31.9 L (5.56%) | L3 | Rejected-Finance L3 |
| 4 | L4₹6.1 Cr+₹38.0 L (6.64%)Rejected-Finance | ₹6.1 Cr+₹38.0 L (6.64%) | L4 | Rejected-Finance L4 |
| 5 | L5₹6.2 Cr+₹43.4 L (7.57%)Rejected-Finance GALI BAWARI WALI NOHARIA BAZAAR SIRSA 125055 HARYANA | SIRSA | HARYANA | 125055 | ₹6.2 Cr+₹43.4 L (7.57%) | L5 | Rejected-Finance L5 |
Tender Value
₹2.9 Cr
EMD Value
₹3.6 L
Closing Date
23 Jan 2024, 6:00 pmClosed
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
HQ Chief Engineer Jalandhar Zone Jalandhar Cantt
COMPLETION OF INCOMPLETE AND BALANCE WORK FOR PROVN OF AUDITORIUM AT JALANDHAR CANTT
2023_MES_604158_4
81056/E8
Open Tender
Civil Works
Lump-sum
180 days
Jalandhar Cantt
All documents as per NIT
8 documents required · 8 mandatory
₹2,000
Garrison Engineer (West) Jalandhar Cantt
₹3.6 L
Yes
14 Feb 2024
21 Dec 2023
27 Jan 2024
21 Dec 2023
23 Jan 2024
9 Jan 2024
Amount
Note: (i) Please refer Schedule 'A' Notes given on serial page No. 21, 22, 23(R), 24 to 26 of tender documents. (ii) Item from Srl No. 3.00 to 12.05 of this document shall be Part-XV (Miscellaneous items) of BOQ (iii) Unless otherwise specified, earth work and excavation shall be measured and paid separately for item No 3.00 to 12.05 of BOQ
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for INCOMPLETE BUILDING WORKS as listed in Schedule 'A' Part-I brought forward from serial page No. 27.
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-II brought forward from serial page No. 32.
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 33.
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS as listed in Schedule 'A' Part-IV brought forward from serial page No. 35.
Lump sum price worked out by the contractor for ROAD, PATH & CULVERT WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 37(R).
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule 'A' Part-VI brought forward from serial page No. 38.
Lump sum price worked out by the contractor for FENCING, COMPOUND WALL & GATE WORKS listed in Schedule 'A' Part-VII brought forward from serial page No. 40.
Lump sum price worked out by the contractor for SITE CLEARANCE AND EARTH WORKS as listed in Schedule 'A' Part-VIII brought forward from serial page No. 41.
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-IX brought forward from serial page No. 44.
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-X brought forward from serial page No. 46.
Lump sum price worked out by the contractor for LIGHTENING PROTECTION WORKS listed in Schedule 'A' Part-XI brought forward from serial page No. 47.
Lump sum price worked out by the contractor for FIRE FIGHTING WORKS as listed in Schedule 'A' Part-XII brought forward from serial page No. 50.
Lump sum price worked out by the contractor for VENTILATION AND SUMMER APPLIANCES WORKS as listed in Schedule 'A' Part-XIII brought forward from serial page No. 51.
Lump sum price worked out by the contractor for DEMOLITION/ DISMANTLING WORKS as listed in Schedule 'A' Part-XIV brought forward from serial page No. 53.
INTERNAL ELECTRIC SUPPLY WORKS (MISC ITEMS OF WORKS)
Supply and fixing modular metal flush box of 8 module complete all as specified and directed.
Supply and fixing RCCB FP AC 25 Amp 415V 50 Hz 10 KA as per IS : 12640-1 & IEC/EN 61008-1 complete all as specified
Supply and fixing RCCB FP AC 63 Amp 415V 50 Hz 10 KA as per IS : 12640-1 & IEC/EN 61008-1 complete all as specified
Supply and fixing MCB, DP 240 volts, capacity 6 to 32 Amps, 50 Hz, 10 KA complete all as specified.
Supply and fixing MCB, SP 240 volts, capacity 6 to 32 Amps, 50 Hz, 10 KA complete all as specified.
Supply and fixing modular dummy plate complete all as specified.
Supply and fixing lamp holder metal ring of modular fittings inlcuding LED lamp 6 W 220-240 volts 50 Hz complete all as specified.
Supply and fixing ceiling fan 5 star rating 1200mm sweep including provision of cord flexible copper conductor 23/0.0076 three core from ceiling rose to connector complete all as specified.
Supply and fixing exhaust fan heavy duty with louvers complete of 300mm sweep corrosion less, double ball bearings with louvers with bolts,nuts and washers ,size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan for giving connection complete allas specified.
Supply and fixing exhaust fan heavy duty with louvers complete of 380mm sweep corrosion less, double ball bearings with louvers with bolts,nuts and washers ,size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan for giving connection complete allas specified. Note for Srl item No. 3.09 & 3.10 : Cost of opening in wall and grouting of mild steel work shall be deemed included in the lump sum cost of the building.
Supply and fixing energy efficient LED, enviornment friendly single tube light fittings surface/ pendent mounted compete with white powder coated slim box type batten of formed CRCA with snap on installer suitable for 1200 mm long 20W LED tube rod batten or LED tube light base complete with 1200m long LED rod 1x20 watt, 6500K for white illumination including all accessories and connection from ceiling rose to connector complete all as specified.
Supply and fixing surface mounted opal polycarbonate diffused 1 x 1 feet aesthetically desinged LED luminaire flat panel soft light and glare free symmetrical illumination of rating 15W 240V 50 Hz and making electrical connection complete in all respect and as specified .
Supply and fixing LED EXIT light fitting 1 x 3 W, 220-240 volts, 50 Hz with red sign "EXIT" with indbuilt battery backup for 2 hours and making electical connection complete all as specified and directed
Supply and fixing energy efficient LED enviornment friendly LED security light B-1 class made up of pressure die cast aluminium housing with high power LED as lighting source and lense embedded for area/ path illumination as per National Lighting Code (SP 72:2010) by using security light of 25 watts (total input power), CCT - 5000- 5500K CRI > 67, PF > 0.95, rated output lumens 2100 Im, operating performance temp - 10 degree centigrade + 45 degree centigrade LED module life span 50000 burning hrs, with toughened glass, external surge and over voltage protection device up to 440V alongwith connection 3 core copper flexible cable of size 0.75 sqmm to be provided with weather proof connector, LED module & driver IP-66 rated duly ISI marked IS:16103 part (1&2) 2012 : efficency 85% constant current Vtd < 10%, lthd < 15% complete with 40mm dia GI pipe light grade 1.5 mtr long bracket and FI 40 x 6 mm clamp 2 Nos with nut bolts etc including painting of clamps with two coats of aluminium paint over a coat of primer (for bldg security lights) complete all as specified.
Supply and fixing energy efficient LED, enviornment friendly, linear and compact 9 watt mirror light with decorative end caps, polycarbonate body and ribbed opal diffuser LED rod 1 x 9W, CCT 6000 K, 220-240 volts, 50 Hz for white illumination including all accessories and connection from ceiling rose to connector complete all as specified and directed
Supply and fixing energy efficient, environmently friendly, long life die cast aluminium IP 65 powerful LED luminaire with high power LED as light source with lumen efficacy>100Im/W, CCT>5700K, operating temperature-10 to +50 degree centrigrade, 220-240 volts, 50 Hz, 240 watt and surge protection 5 KV, pf>0.95 complete all as specified and directed
Supply and fixing halogen light/ stage filler light 1000W/ Eqvt LED light fitting 220-240 volts, 50Hz complete all as specified and directed
Supply and fixing fresnel spot light fitting suitable watts 220-240 volts, 50 Hz complete all as specified and directed
Supply and fixing profile spot light for sharp focusing 220-240 volts, 50 Hz complete all as specified and directed Note for Srl No. 3.16 to 3.19 : The rates also includes one suitable rating modular type dimmer switch to control the light all as shown in drawings
Supply and fixing porch light energy efficient LED, enviornment friendly, aestheitically designed, moulded body, ceiling light LED fixture IP 54 with diffuser to give glare free light with Lamp LED 1 x 8/9 W 6000K, 220-240V, 50 Hzcomplete all as specified and directed
Supply and fixing sub main wiring with two single core FRLS PVC insulated standard copper conductor 4 Sqmm and 1 x 4 Sqmm for earth continuous earth wire including suitable PVC conduit medium grade ISI marked all as specified and directed. Note :Two runs of PVC cable 4 sqmm & one run of earth wire 4 sqmm will be considered as one unit.
Supply and fixing sub main wiring with three single core FRLS PVC insulated standard copper conductor 4 Sqmm and 2 x 4 Sqmm for earth continuous earth wire including suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Three runs of PVC cable 4 sqmm & two runs of earth wire 4 sqmm will be considered as one unit.
Supply and fixing sub main wiring with four single core FRLS PVC insulated standard copper conductor 6 Sqmm and 2 x 6 Sqmm for earth continuous earth wire including suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Four runs of PVC cable 6 sqmm & two runs of earth wire 6 sqmm will be considered as one unit.
Supply and fixing sub main wiring with four single core FRLS PVC insulated standard copper conductor 16 Sqmm and 2 x 16 Sqmm for earth continuous earth wire inlcuidng suitable PVC conduit medium grade ISI marked all as specified and directed. Note : Four runs of PVC cable 16 sqmm & two runs of earth wire 16 sqmm will be considered as one unit.
Providing of pit, GI pipe for watering with funnel and wire mesh, GI strip upto equipment/ panel/ test point with protection pipe & testing only complete with galvanized steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 25 x 4mm dia connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron light grade 40mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:3:6) type C-2 using graded stone aggregate and RCC cover in M-25 (Design mix) and all as shown in Electrical Plate No. 3 of MES Schedule (Part-I) of 2009 complete all as specified and directed. Note : The balance work involves providing of pit i.e. PCC chamber in cement concrete (1:3:6) type C-2 using graded stone aggregate & RCC cover in M-25 (Design mix) all as shown in electrical plate No. 03 of MES Schedule (Part-I) of 2009, GI pipe 20mm bore medium grade with funnel and wire mesh, GI strip upto equipment/ Panel/ test point with protection pipe and testing of earth.
Supply and installing single sided LED signage (Gents Toilet) with 3W LED of red/ green colour including built in battery back up for 2 hours complete all as specified and directed.
Supply and installing single sided LED signage (Ladies Toilet) with 3W LED of red/ green colour including built in battery back up for 2 hours complete all as specified and directed.
M&L for installing LED row light fitting 2 watt fixed in recessed in chair including painting of alphabets & numbers as directed by Engineer--in-Charge.
Supply and installation of electronic inverter of 3 KW capacity complete including 12V maintenance free battery of 180AH and of required qty as recommended by manufacturer for functioning and suitable for inverter, including trolley for mounting inverter and batteries, PVC multistranded copper connectiong wire of appropriate size etc complete all as specified and directed.
Supply and installing single sided LED signage (Entry) with 3W LED of red/ green colour including built in battery backup for 2 hours complete all as specified and directed.
INTERNAL WATER SUPPLY WORKS
Supply and fixing single lever basin mixer complete all as specified. Make : Jaquar (Lyric) Code No LYR 38001B
Supply and fixing CP bib cock with wall flange complete all as specified. Make : Jaquar CodeARI-39037 without popup waste.
Supply and fixing angular stop cock with wall flange complete all as specified. Make : Jaquar Code ARI-39053.
Supply and fixing bottle trap (with internal partition) 32mm size with 250mm long wall connection pipe and wall flange complete all as specified. Make : Jaquar Code No. ALD 769L250x190.
Supply and fixing 450mm long braided hoses with two 15mm nuts & rubber washer without nipple complete all as specified. Make : Jaquar Code No. ALD 805B
Supply and fixing hand drier smart flow, stainless steel finish stain complete all as specified. Make : Jaquar Code No. HDR-SAP-M99ACS.
Supply and fixing swivel mirror complete all as specified. Make : Jaquar Code No. ACN 1195N.
Supply and fixing 15mm bore CP bib mixer for mixing hot and cold water complete all as specified. Note for ser No 4.01 to 4.08 : The items to be provided as per Jaquar make of catalogue / Code as mentioned against each item. The rate of fixing accessories and other minor items required for fixing shall be included in above rate.
EXTERNAL ELECTRIC SUPPLY WORKS
Material and labour for providing coping of pre-stressed concrete pole 11 metre long, cross section 152mm x 152mm at top and 152mm x 260mm at bottom class-9 including zebra painting of poles with two coats of synthetic enamel paint over a coat of primer in black & white strips upto 1.5mtr height from top of PCC coping in 30cm alternate block and numbering of poles complete all as specified. Note : Pre-stressed concrete pole 11 metre long is installed at site.
Shifting of Transformer of capacity 200 KVA after dismantling existing electrical connetions, and shifting with the help of crane to new 4 pole structure and making all electrical connections complete.
Supplying and Installing hot dip galvanized steel octagonal poles (IS 5986 Gr. Fe 510) 7.0 metre long, top dia 70mm, bottom dia 130mm having thickness 3mm, having door opening of size 500mm above 500mm from ground level, with CI base plate of size 240 x 240 x 16mm having PCD 220mm, foundation J bolts M20 x 700mm (570 + 130 of J), nuts & screws and having hot dip galvanized single plain arm bracket 1000mm overhang with 48.3 mm outer dia pipe of thickness 3.2mm fixed on top with bolts complete all as specified. Note : PCC and earth work shall be measured and paid separately.
(f) OUTDOOR ENCLOSURE Outdoor type enclosure made of 2 mm thick GI sheet. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23D degree of protection for Transformer compartment. The enclosure exterior shall be polyurethene metallic painted. Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment. Interconnection Between HT switchgear & Transformer using XLPE Single core cable & Interconnection between Transformer & LT switchgear using Busbars. Internal earthing connections. All metallic components shall be earthed to a common earthing point. (g) TRANSFORMER 500 KVA, 11KV / 433V, DYn11, ONAN, hermetically sealed with corrugated tank design, copper wound, oil type transformer with off load tap changer of -5% to +5% in steps of 2.5 % with initial filling of oil. (h) INTERCONNECTION & EARTHING Internal factory connections Between HT switchgear & Transformer shall be done using 1Cx3x95Sq.mm XLPE single core cable & Interconnection between Transformer & LT switchgear using Busbars. Internal earthing connections. All metallic components shall be earthed to a common earthing point. Note : (i) Plinth / foundation for CSS shall be as per design & specification of the manufacturer & the cost shall be included in the quoted rates. (ii) Transformer make shall be as per CSS manufacturer's design. (iii) Drawing of CSS shall be approved by GE before placement of order. (iv) Pre-commissioning inspection shall be carried out by SEI from HQ CE WC before completion of work within overall quoted rates. (v) Pre-dispatch inspection shall be carried out by rep of Accepting Officer.
Installation, testing & commissioning only of microprocessor based automatic power factor control LT panel board (MPFCS) 415 volt, 50 cycles per second, cubical type, front & back openable double leaf type, dust & vermin proof with locking arrangement, powder coated with approved colour, made out of CRCA sheet 3.15 mm, outdoor type with canopy, cable entry glands, double compression type, duly pre-wired with suitable pillars made out of 50mm x 50mm x 6mm angle iron, grouted in & including PCC (1:2:4) using 20mm graded stone aggregate complete as per IS: 8623-1993 & all as per latest IS specifications & suitable for housing & including following accessories : - (a) Incoming MCCB of 500 Amps TP 36 KA rupturing capacity, 3 pole thermal magnetic release type with shunt trip coil - 01 No. (b) Copper bus bar duly insulated with colour coded heat shrinkable sleeve insulation for three phase four wire system of 800 Amps capacity rating with suitable size/ type non hygroscopic, non combustible track resistant, high strength FRP/ MC/ DMC insulators. (c) Capacitor switching contactor suitable for 1 x 10 + 1 x 15 + 10 x 25 capacity shunt capacitors (Contactor Amps rating shall not be less than 1.5 times nominal rated current), three poles, coil voltage 440 volts. Each contactor shall be protected with MCB TP 10 KA, D-curve type (MCB to be provided for 1.33 times KVAR ie 100% current capacity of the MPFCS irrespective of the fact that contactor's rating is 1.5 times). (d) One set current transformer (CTs) of ratio 500/5 to be fixed on bus bars of existing panel including connection with 2 core 1.5 sqmm armoured copper conductor cable complete with gland etc. (e) Shunt capacitors MPP type heavy duty 275 KVAR distributed in steps of 8 stages with configuration (1x10 + 1x15 + 9x25) and 1 x 25 KVAR (for fixed KVAR) directly connected to maintain power factor at 0.99 or unity, housed in self-extinguishing insulating material, with built in over pressure safety devices (Capacitors shall discharge automatically with electronic reactance discharge KA of suitable rating in kiloohm & watts, when power supply is switched off) 440 volts, 50 Hz, minimum static life expectancy of more than 1,15,000 hours & switching life (minimum 5000 switching operations per year) 1,00,000 hours, output capacitance tolerance of 0% to 10%. Di-electric losses less than 0.5 watt per KVAR, temperature (Max.) 55°C, IP 30 protection all as per latest IS. Note : LT panel has been kept at site and the same shall be handed over to the contractor through proper inventory.
(f) Wiring of complete panel board with multi stranded 2.5 sqmm flexible PVC copper wires & copper thimbles complete with number sleeve markers. (g) Microprocessor based automatic power factor control relay unit suitable for twelve stages of capacitor bank. The processor shall have the following features: - (i) Suitable for programming at site. (ii) Over & under voltage trip point ± 15%. (iii) Self adjusting switching sequence. (iv) PF adjusting range upto 0.8 lag to 0.99 lead by digital setting keys. (v) Auto calculation of C/K value. (vi) 50 Hz frequency, 433 volts, 3 phase system. (vii) Single phase prevention of capacitors & phase reversal for capacitors including electronic over load inter connected with MCCB. (viii) 50 Hz frequency, 433 volts, 3 Phase system. (ix) Indication for operational state of capacitors LED type. (x) Current input 0.5 Amps. (xi) Low current release less than 50mA, voltage release 35 milli seconds, voltage burden 5 VA, Current burden 0.5 VA. (h) Exhaust fan of 150 mm sweep for cooling of panel.
Material and labour for making cable connections with lugs to LT Panel, testing and commissioning of LT indoor panel board (factory made of approved CPRI) not less than 150 cm x 100 cm x 50 cm mounted indoor type made out of CRCA sheet 2 mm thick dust proof, powder coated from both side, individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and copper bus bar of capacity 300 Amps rating for phase and neutral mounted on hygroscopic insulator fixed in a separate bus bar chamber separate compartment for incoming and outgoing feeder prewired with suitable size of copper conductor cable including fitted on 50x50x6mm angle iron channel with PCC foundation and provision of lugs and bushing for housing the following for Auditorium bldg and SL :- (i) Electrolite copper bus bar 300 amps for phase & neutral-04 Nos (ii) MCCB 4P 160 Amps, 25 KA- 01 Nos (In coming) (iii) MCCB 4P 100 Amps, 25 KA - 01 No. (iv) MCCB 4P 63 Amps, 25 KA - 01 No. (v) MCB TPN 32 Amps - 04 Nos (SL+W/S Pump+Terrace Tank Pump+ High Mast) (vi) Multi functional digital Voltmeter and ampere meter including suitable and appropriate CTs-01 Set (vii) Indicator lamp (LED R-Y-B)- 01 Set Notes : (i) All MCCBs shall be having microprocessor based release with inbuilt earth fault module. (ii) LT panel has been installed at site with all accessories.
Material and labour for making cable connections with lugs to LT Panel, testing and commissioning of LT outdoor panel board (factory made of approved CPRI) not less than 150 cm x 100 cm x 50 cm mounted indoor type made out of CRCA sheet 3.15 mm thick dust proof, powder coated from both side, individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and copper bus bar of capacity 400 Amps rating for phase and neutral mounted on hygroscopic insulator fixed in a separate bus bar chamber separate compartment for incoming and outgoing feeder prewired with suitable size of copper conductor cable including fitted on 50x50x6mm angle iron channel with PCC foundation and provision of lugs and bushing for housing the following for Auditorium bldg and SL :- (i) Electrolite copper bus bar 400 amps for phase & neutral-04 Nos (ii) MCCB 4P 250 Amps, 36 KA- 01 Nos (In coming) (iii) MCCB 4P 160 Amps, 16 KA - 02 No. (iv) MCCB 4P 63 Amps, 16 KA - 02 No. (v) Multi functional digital Voltmeter and ampere meter including suitable and appropriate CTs-01 Set (vi) Indicator lamp (LED R-Y-B)- 01 Set Notes : (i) All MCCBs shall be having microprocessor based release with inbuilt earth fault module. (ii) LT panel has been installed at site with all accessories.
Material and labour for making connections with lugs to LT Panel, testing and commissioning of LT outdoor panel board (factory made of approved CPRI) not less than 90 cm x 90 cm x 50 cm mounted outdoor type made out of CRCA sheet 3.15 mm thick dust proof, powder coated from both side, individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply including bus bar chamber and copper bus bar of capacity 300 Amps rating for phase and neutral mounted on hygroscopic insulator fixed in a separate bus bar chamber separate compartment for incoming and outgoing feeder prewired with suitable size of copper conductor cable including fitted on 50x50x6mm angle iron channel with PCC foundation and provision of lugs and bushing for housing the following for Auditorium bldg and SL :- (i) Electrolite copper bus bar 300 amps for phase & neutral-04 Nos (ii) MCCB 4P 160 Amps, 16 KA- 01 Nos (In coming) (iii) MCCB 4P 63 Amps, 16 KA - 03 No. (iv) Multi functional digital Voltmeter and ampere meter including suitable and appropriate CTs-01 Set (v) Indicator lamp (LED R-Y-B)- 01 Set Notes : (i) All MCCBs shall be having microprocessor based release with inbuilt earth fault module. (ii) LT panel has been installed at site with all accessories.
S&F LED street light luminaire 45 watt in epoxy powder coated pressure die-cast aluminium housing of size 325mm x 185mm x 72mm with 5% tolerance, heat resistant toughened clear glass fixed with SS screws controlled with potted CVCC type BIS marked electronic driver duly enclosed of approved brand only in housing having protection against over voltage, short circuit and open circuit and surge protection against lightening of 5KV minium in circuit and 5 KV outside the driver but inside the fixture with IP-66, class-1 protection for LED and control gear compartments with high power LED chips of rating 2.5 to 3 watt (maximum) with colour temperature 5700 K (max) and with secondary optics modular independent lenses provided with casing and caping to minimize glare and for better distribution of light suitable for voltage band 100 volts to 300 volts, power factor 0.95 (min) having efficacy 100 lumens/watt. Brand name shoud be embossed on fixture to ensure India brand only including connection by providing PVC insulated 2 core copper conductor 1.0 Sqmm cable from junction box at the bottom of pole to the connector of street light at the top of the pole complete all as specified and directed. Note : (i) All LED fittings shall be made in India only. (ii) All LED fittings shall have supporting LM-79 & LM-80 test certificate from Govt. approved NABL accredited lab showing the parameters duly signed by the local office bearer of manufacturer. (iii) All LED fittings shall have 5 years written warranty from local office bearer of manufacturer.
S&F fibre body loop in loop out enclosure of size 230mm x 170mm x 105mm, consisting of HD bakelite connector strip inlcuding MCB 6 Amp SPN, fixing of enclosure with pole using 40 x 6mm size MS F1 clamps of requried shape with bolts, nuts & washers compelte all as specified and directed Note : MCB shall be measured and paid for separately
Supply & fix time switches astro type (having longitude and latitude of Indian cities in memory) 250 V single phase of 40 Amps rating with contactor and MCB TPN as incoming and outgoing protection totally enclosed in SMC box of suitable size including mounting bracket of MS flat 3mm thick made to shape complete all as specified and directed
S&F energy saving LED flood light fitting with high pressure die-cast aluminium housing with IP66 Class-I protection, having discrete LED structure, extruded aluminium heat sink, surge protection device of 10 KV, suitable for voltage variation 120 to 270 volts and system efficacy 90 lumens per watt, THD < 10%, power factor > 0.95 and protection for toughened glass IK05, with PMMA optics lens for uniform distribution with constant current driver and mounting cradle complete of 150 watt or above including mounting bracket and fixing accessories like nuts/ bolts/ washer of suitable size complete all as specified and directed. Note : Fittings and drivers shall be made in INDIA only and supplied with LM 79 and LM 80 reports issued from NABL accredited laboratory along with NABL certificate along with 2 years written warranty for complete fitting including driver from local manufacturer's office.
Material and labour for earthing complete for transformer/LT Panels with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6mm in and including GI pipe 40mm bore light grade as protection pipe (from top of earth plate up to the body of equipment) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe medium grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate and angle iron frame including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 5 of SSR Part-I (2009) testing on completion complete all as specified. Note : Cost of protection pipe up to 7.5metres from earth electrode will be included in the unit rate quoted by the contractor.
All as per item No. 5.15 here-in-before but providing of pit, GI pipe for watering with funnel & wire mesh and GI strip upto equipment/ panel/ test point with protection pipe and testing only. Note : The balance work involves providing of pit i.e. PCC chamber of size 300 x 300 x 300mm in cement concrete (1:3:6) using 20mm graded stone aggregate & RCC cover (1:2:4) type B-1 using 20mm graded crushed stone aggregate and angle iron frame all as shown in electrical plate No. 05 SSR (Part-I) of 2009, GI pipe 20mm bore medium grade with funnel and wire mesh, GI strip upto equipment/ Panel/ test point with protection pipe and testing of earth
All as per item No. 5.15 here-in-before but using GI wire of 4mm dia as earth lead in 15mm bore protection pipe and galvanised earth plate of size 60cm x 60cm x 6mm as earth electrode (2 for 2 pole structures, 1 for GO switch, 1 for lightening arrestor) complete all as specified.
All as per item No. 5.17 here-in-before but providing of pit, GI pipe for watering with funnel & wire mesh and GI strip upto equipment/ panel/ test point with protection pipe and testing only.
Supply and fixing LED for signage with built in battery back up integral double sided LED signage with extruded aluminium hsg incorporate LED driver, battery and other accessories complete all as specified.
Supply and fixing LED 6 watt decorative bollards with opal acrylic with IP65 protection complete all as specified and directed.
Supply and fixing LED 12 watt decorative post top lantern luminaire with IP 65 protection complete all as specified (For Gate Lights).
Supply and fixing MCB C-Curve, 10 KA, SP 06 Armp, 240 volts
Supply and fixing switch air break gang operated out door type HT 11 KV triple poles 200 Amps with fixed contacts of phosphorus bronze and moving contacts of copper with mechanically operating from ground level vertical mounted complete with HT insulator on steel frame operating rod made out of 25mm GI pipe medium grade worked from ground level with handle and locking arrangement with 12 insulators with test complete all as specified and directed. Note : (i) Clamps/ cross arms shall be measured and paid for separately. (ii) Original test certificate of manufacturer shall be produced, without which no payment shall be made.
Supply, errection, testing and commissioning of 15 Mtr high mast, suitable for 180 Km/hr wind speed continuously tapered, polygonal cross section, not less than 20 sided manufactured from MS plates, hot dip galvanized complete with all its accessories and suitable for mounting max 06 Nos of 180 watt LED luminaires consisting of head frame, pully assembly, motorized movable lantern carriage, double frum winch, 3/4 point suspension system with steel wire rope 6mm dia 97/19 gauge, trailing cable - 5 core x 4 sqmm, with integral power tool and control panel housing with suitable control gears and circuit for the operation of high mast complete with following :- Design and casting of suitable shallow foundation with M-15 concrete for the high mast considering the safe soil bearing capacity at site as 10 Ton per square meter at 2m depth, design factor for safety 1.2, considering wind speed (Km/hr) is 180 (IS 875, 1987) and depth of foundation as per height of high mast pole and minimum 12 Nos of foundation bolts (dia minimum 25mm) (b) Aviation obstruction lights with two numbers of lED lights fittings complete. (c) Supply and erection of hot dip galvanised lightning arrestor with 25 x 3 mm hot dip galvanised strip down conductor upto ground level. (d) Supply, installation, testing and connecting to electical system distribution board (outdoor type - 01 No) suitbale size, factory made, double door, cubical and pedestal tyupe, compartmentalised design, back door hinged type & openable, fabricated out of 3.15 mm thick CRCA steel sheet, weather/ dust/ vvermin proof, IP 65 protection, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with one number lock with duplicate key duly painted with power coated paint and providing the following items including connection of all incoming and outgoing cables using suitable size lugs and glands, danger notice board, with supporting legs of angle iron of size 50 x 50 x 6mm of length 100 cm long duly grouted in PCC (1:3:6), 50cm below ground level and 50cm above ground complete all as speccified and directed by Engr-in-Charge including comprising of following items :- (i) MCCB 63 Amp, 4 pole, 415 Volts, 35 KA breaking capacity - 01 No. (ii) Power contactor 3 pole, AC, 70 Amps, 50 Hz, ML type. (Make : L&T Cat Pat No SS90910 Model : ML-4) - 01 No. (iii) Timer switch, light sensing type, - 01 No. (iv) MCB 3 pole 20 Amps, AC, 415 Volts, 50 Hz - 01 No. Note : Excavation, PCC, nuts, bolts etc retun filing, removal all shall be deemed to be included in quoted rates as per specifications/ foundation drawing of manufacturer.
Supply & fixing hot dip galvanised single plain arm bracket 1000mm overhang with 48.3mm outer dia pipe of thickness 3.2mm fixed on top with bolts for hot dip galvanized steel (IS:5986 Gr, Fe 510) octagonal pole 7.0m long, top dia 70mm, bottom dia 130mm having thickness 3mm complete all as specified & directed.
EXTERNAL WATER SUPPLY WORKS
Testing and commissioning of monoblock centrigugal pumpset, 80 x 65mm suction and delivery size, 12.5 ltr/ sec at 20 mtr head complete with TEFV electric squirrel cage induction motor, 2 pole, 3 phase, 415 volts, 50 Hz with brass impeller, carbon steel shaft, chrome steel shaft sleeve with cast iron delivery casing and motor body including all accessories, necessary foundation of size 0.75 mtr x 0.45 mtr x 0.3 mtr, suitable size base frame/ mounting frame madeup of MS channel/ angles with nut bolts and antivibration pad and internal electrical connection including required copper cable from the motor to starter in suitable size PVC conduit, concealed in wall/ floor, painting the inlet and outlet pipe with synthetic enamel paint of colour as directed at site all as sepcified. Note : Monoblock centrifugal pump set panel is installed at site.
S&F cast iron foot valve of size 100mm dia conforming to IS-4038, PN 0.2 including diconnecting complete all as specified and directed
Material and labour for making cable connections with lugs to LT Panel, testing and commissioning of LT power distribution panel board of suitable size made out of CRCA sheet 2mm thick indoor type totally enclosed with hinged doors, fixed on MS rail for safe standing on floor, weather and water proof as per IS-8623 aluminium bus bar with half neutral, mounted on insulators suitable for 3 phase 4 wire LT, AC, 50 Hz, 433 volts, 200 Amps capacity and indicating lamp (Red, Yellow, Blue) complete with necessary locking arrangements all as specified and directed inlcuding painting with two coats of syntheitc enamel paint over a coat of red oxide primer, internal electric connections as required and provision of the followings :- (a) MCCB 63A, 3 pole 15 KA breaking capacity, adjustable overload and short circuit setting, 415 volts - 01 No (incoming) (b) MCCB 32A, 3 pole 10 KA breaking capacity, adjustable overload and short circuit setting, 415 volts - 02 Nos (motor connection) (c) MCB 6-32A, SPN 230 volts-02 Nos (building lighting) (d) DOL starter suitable upto 7.5 HP induction motor with relay range 13-22 Amp and single phase preventor-02 Nos (e) Multi function meter 3 phase, LCD display (f) Indication lamp set of three-02 set Note : LT panel has been installed at site with all accessories
Cutting in position existing 150mm bore CI water main and insertion of tee 150 x 150 x 100mm bore for tapping out branch connection inlcuding other connected fittings and excavation earthwork etc complete all as specified and directed
M&L construction of brick masonry valve pit of size 1.20 x 1.20 x 1.20 mtr (internal dimension) including earth work and excavation if any type of soil and disposal of surplus soil at distance not exceeding 50 mtr away from site inlcuding plastering internally in CM (1:4) and flush pointing on brick work externally as the work proceeds in the same mortar with angle iron frame 40 x 40 x 6mm hold fast MS sheet cover 3.15mm thick, handle hinged to frame and locking arrangment including black syntheitc enameled paint duly painted over a coat of red oxide primer all as per Drg No CEJZ/TD-1060/08 Sh 1/3 to 3/3 including dismantling existing pit complete all as specified and directed
LIGHTENING PROTECTION WORKS
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6mm with & including GI pipe 50mm bore light grade as protection pipe (upto the body of equipment max 7.50 metre) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of coal dust and common salt 15cm thick, all around top and bottom and watering pipe 20mm bore of GI pipe medium grade with funnel and wire mesh complete all as shown in Electrical plate No. 3 of SSR Part-I (2009), testing on completion including PCC chamber (1:3:6) using 20mm graded stone aggregate, RCC M-25 cover, angle iron frame and necessary earth work complete all as specified with the following :- (a) Test point GI for size 75mm x 75mm x 25mm (b) Watering pipe GI light grade 20mm dia from top of the earth electrode upto MS funnel with brass wire mesh embedded in floor of PCC earth pit. (GI funnel should properly tightened on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits. (c) PCC earth pit 30cm x 30cm constructed in PCC (1:2:4) type B-1 exposed surfaces smoothly finished with 15mm thick cement mortar (1:6) plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover. (d) Angle iron frame made of 40 x 40 x 4mm angle iron for 30 x 30mm PCC pit for holding the pit cover. Note :- 1. The unit rate shall include for protection pipe GI water pipe, wire mesh, funnel, excavation, RCC pit cover, test point, GI strip of size 32 x 6mm from the earth plate and upto metallic body of the quipment/ panel board etc. 2. PCC pit shall be provided at least 0.50 metres away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction elbow etc shall be deemed to be included in the unit rate. 3. RCC pit cover shall be 80mm thick precast RCC (1:2:4) type B-1 reinforced with XPM weighting not less than 4 Kg/sqm in lieu of CI cover.
All as per item No. 7.01 here-in-before but providing of pit, GI pipe for watering with funnel & wire mesh and GI strip upto equipment/ panel/ test point with protection pipe and testing only. Note : The balance work involves providing of pit i.e. PCC chamber in cement concrete (1:3:6) using 20mm graded stone aggregate & RCC cover in M-25 (Design mix) & all as shown in electrical plate No. 03 MES Schedule (Part-I) of 2009, GI pipe 20mm bore medium grade with funnel and wire mesh, GI strip upto equipment/ Panel/ test point with protection pipe and testing of earth.
FIRE FIGHTENING WORKS
S&F branch pipe and nozzle for 20mm dia hose reel conforming to IS 8090 complete all as specified and directed.
S&F fire extinguisher dry chemical powder (ABC) type, 6 Kg capacity (IS : 2171/13849, 14609) complete all as specified and directed.
S&F fire extinguisher dry chemical powder (ABC) type, 4 Kg capacity (IS : 2171/13849, 14609) complete all as specified and directed.
S&F fire extinguisher ISI marked CO2 6.5 Kg capacity, squeeze grip operated, light weight (IS : 15683 or 2878) complete all as specified and directed.
S&F fire extinguisher ISI marked CO2 4.5 Kg capacity, squeeze grip operated, light weight (IS : 15683 or 2878) complete all as specified and directed.
Material and labour for making cable connections with lugs to LT Panel, testing and commissioning only of LT indoor panel board (factory made of approved CPRI) not less than 150cm x 100cm x 50cm mounted indoor type made out of CRCA sheet 2mm thick dust proof, powder coated from both side, individual door, factory locking system with two side ventilation suitable for working on 415 volt AC supply inlcuding bus bar chamber and copper bus bar of capacity 200 Amps rating for phase and neutral mounted on hygroscopic insulator fixed in a separate bus bar chamber separate compartment for incoming and outgoing feeder prewiered with suitable size of copper conductor cable inlcuding fitted on 50 x 50 x 6mm angle iron channel with PCC foundation and provision of lugs and bushing for housing the following :- (i) Electrolite copper bus bar 200 Amps for phase & Neutral - 04 Nos (ii) MCCB 4P 100 Amps, 25 KA - 01 Nos (Incoming) (iii) MCCB TP 63 Amps, 10 KA - 03 Nos (iv) Multi functional digital voltmeter and ampere meter including suitable and appropriate CTS-01 Set (v) Indicator lamp (LED RYB) - 01 Set Notes : (i) All MCCB shall be microprocessor based release with inbuilt earth fault module. (ii) LT panel has been installed at site with all accessories.
Material & labour for earthing complete for transformer/ LT panels with galvanized steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, connected with and including GI strip 32mm x 6mm in and including GI pipe 40mm bore medium grade as protection pipe (from top of earth plate upto the bodty of equipment) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and comon slat 15cm thick, all around inlcuding top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300 x 300 x 300mm (top of chamber minimum 15cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and angle iron frame inlcuding necessary excavation/ earth work in any type of soil/ rock and as shown in electrical plate No. 5 of SSR part-I (2009) testing on completion complete all as specified. Note Cost of protection pipe upto 7.5 metres from earth electyrode will be included in the unit rate quoted by the contractor.
All as per item No. 8.07 here-in-before but providing of pit, GI pipe for watering with funnel & wire mesh and GI strip upto equipment/ panel/ test point with protection pipe and testing only. Note : The balance work involves providing of pit i.e. PCC chamber of size 300 x 300 x 300mm in cement concrete (1:3:6) using 20mm graded stone aggregate & RCC cover (1:2:4) type B-1 using 20mm graded crushed stone aggregate and angle iron frame all as shown in electrical plate No. 05 SSR (Part-I) of 2009, GI pipe 20mm bore medium grade with funnel and wire mesh, GI strip upto equipment/ Panel/ test point with protection pipe and testing of earth.
DG SET WORKS
Installation & commissioning of DG set of capacity 125 KVA all as directed by Engineer-in-Charge. Notes :- (i) Maintenance chart and manufacturer instruction shall be displayed on wooden board including catlog board within area all cost quoted. (ii) Foundation for mounting of DG set shall be done as per manufacturer design within overall cost quoted. (iii) DG Set of capacity 125 KVA has been kept at site and the same shall be handed over to the contractor through proper inventory.
Providing of pit, GI pipe for watering with funnel & wire mesh and GI strip upto equipment/ panel/ test point with protection pipe and testing complete for transformer/ LT panels with galvanized steel earth plate electrode 60cm x 60cm x 6.3mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.5 metre below ground level, connected with and including GI strip 32mm x 6mm in and including GI pipe 40mm bore medium grade as protection pipe (from top of earth plate upto the bodty of equipment) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and comon slat 15cm thick, all around inlcuding top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300 x 300 x 300mm (top of chamber minimum 15cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-1 using 20mm graded crushed stone aggregate and angle iron frame inlcuding necessary excavation/ earth work in any type of soil/ rock and as shown in electrical plate No. 5 of SSR part-I (2009) testing on completion complete all as specified. Notes : (i) Cost of protection pipe upto 7.5 metres from earth electyrode will be included in the unit rate quoted by the contractor. (ii) The balance work involves providing of pit i.e. PCC chamber of size 300 x 300 x 300mm in cement concrete (1:3:6) using graded stone aggregate & RCC cover (1:2:4) type B-1 using 20mm graded crushed stone aggregate with angle iron frame all as shown in electrical plate No. 05 SSR (Part-I) of 2009, GI pipe 20mm bore medium grade with funnel and wire mesh, GI strip upto equipment/ Panel/ test point with protection pipe and testing of earth.
VENTILATION AND SUMMER APPLIANCES WORKS
S&F of pedestal fans, 450mm sweep, 230 volts single phase oscillating type 230V, AC 50 Hz complete all as specified and directed.
S&F air circulator fan, 450mm sweep 230 volts single phase oscillating type 230V, AC 50 Hz including fixing accessories complete all as specified and directed
Supply and fixing voltage stabilize electronic type for automatic operation,single phase naturally air cooled indoor type and designed for input variation between 170 volts to 270 volts with output voltage stabilized at 230 volt with accuracy of + 2.5% and of capacity 3.8/4 KVA complete all as specified.
Supply and fixing SICT of commercial air curtain unit for prevention of dust and conditioned air losses,three phase 440 volts 50 HZ, made out of MS/CRCA sheet min thickness 18 gauge finished with two coat of red oxide primer and final coat of synthetic enamel paint (over backed) with MS-CRC 18 gauge square perforated suction grills, aluminum alloys fans and single phase electric motor, nozzles etc,complete with fittings and accessories so as to produce 1-1.5m/sec air velocity at floor level for door opening of size 64"x 90" complete all as specified and as directed.
Road, Path, & Culvert Works
M&L for providing and marking broken centre line./side line/zebra line on road pavement and the like of any description & width ,with thermoplastic paint hot applied with machine ,confirming to BS 3262 and according to the specification laid down by IRC & MOST (Ministry of surface transport) specification 2001 (4th revision) complete all as specified
STAGE LIGHTING WORKS
S&F recess mounted diffused optics LED downlight elegantly designed presure die cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and separated replaceable electronic driver compatible for analog dimming of rating 20/21 W 50 Hz, 220-240 volts compete and making electrical connection all as specified and directed. Note : The rates inlcudes necessary clamps, nut bolts etc. for mounting of downlights on ceiling/ false ceiling and includes one suitable rating modular type dimmer switch to conroled 07 Nos of downlights from projector room complete all as specified and directed
S&F step light luminaire powder coated die cast aluminium housing IP 65 protection 3/4W, 220-240 volts 50 Hz and making electrical connection complete all as specified and directed
M&L for remote control transmitter with 42-channel for the control of 6 zones and 4 light scenes with dim UP/ DOWN and OFF function complete all as specified and directed. Make : Bajaj/ Crompton/ Philips
M & L for fabricating and installing of MS pipe ladders to be provided on sides of the stage to be fixed on the GI pipe or top grid, make of 50mm x 25mm MS pipe complete all as specified and directed.
Supply, fixing & testing of perforated MS cable trays 40 x 100 x 40, 2mm thick including horizontal and vertical bends, reducers, tees, cross members and other accessories as required and duly suspended from the ceiling with MS suspenders and including painting with powder coating etc complete all as specified and directed.
kailu construction co
M/S Vinod Kumar
N.R.Builders
YESH BUILDERS
A.V BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .