| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.8 LAccepted-AOC PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹33.4 L+₹47,056.50 (1.43%)Rejected-Finance WZ 250 B 2 GALI NO 08 SADH NAGAR I PALAM COLONY NEW DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹40.8 L+₹7.9 L (24.0%)Rejected-Finance E 30 RAJIV NAGAR BEGUMPUR NEW DELHI 110086 | NEW DELHI | NEW DELHI | DELHI | 110086 | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹41.3 L+₹8.4 L (25.5%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹42.7 L+₹9.8 L (29.7%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
3 Jul 2023, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
REPAIR/ REPLACEMENT OF SEWAGE LINE, CLEANING OF MAINHOLE, SEPTIC TANK AND MISC JOINERY WORKS INCLUDING REPAIR/ REPLACEMENT OF UNSV PARTS OF LT PANEL INCLUDING EARTHING, DB AT KANDHAR, 1 WEC, EETSU, WEE, RR COLONY, 105 TA BN, RR COLONY AND ADJOINING A
2023_MES_601487_1
GE/C-18/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE (Central) Delhi Cantt-10
As Per NIT
9 documents required · 9 mandatory
₹500
Yes
GE (Central) Delhi Cantt-10
₹1 L
Yes
17 Jul 2023
6 Jun 2023
5 Jul 2023
6 Jun 2023
3 Jul 2023
20 Jun 2023
6 Jun 2023 - 20 Jun 2023
Amount
Cleaning of EWCs, IWCs, bottle traps, Nahani Traps, Gully traps and Floor traps etc and CI/PVC Pipes all types top to bottom including junctions etc, Cleaning of sewage line upto GT in the area of 1 wec, eetsu and wee wksp (Md accn and all types of Accn including multistory bldg ). complete all as specified and as directed.
Cleaning of GTs in the area of 1 wec, eetsu and wee wksp (Md accn and all types of Accn) complete all as specified and as directed.
Cleaning of Manhole depth of 0.9 mtr and any size of MH in the area of 1 wec, eetsu and wee wksp (Md accn and all types of Accn) and taking out sludge and depositing complete all as specified and as directed.
Cleaning of Manhole depth exc 0.9 mtr but n exc 1.20 mtr and above of any size of MH in the area of 1 wec, eetsu and wee wksp (Md accn and all types of Accn) omplete all as specified and as directed.
Cleaning of Sewage line from GT to Ist Manhole in the area of 1 wec, eetsu and wee wksp (Md accn and all types of Accn) complete all as specified and as directed. Note-cleaning of sewage line daimeter upto 100mm to300mm.
Cleaning of sewage line n.exc 15mtr length in the area of 1 wec, eetsu and wee wksp (Md accn and all types of Accn). complete all as specified and as directed. Note-cleaning of sewage line daimeter upto 100mm to300mm.
Cleaning of Sewage line 0.00mtr to 30.00mtr and onwards in length in the area of 1 wec, eetsu and wee wksp(Md accn and all types of Accn) complete all as directed and as specified. (Note :- This item will be measured if length exceed from 30.00mtr.and cleaning of sewage line daimeter upto 100mm to300mm Note :- For execution of item from Srl No. 1 to 7 above Agency should deploy minimum of 04 Nos Safaiwala and 01 Nos Supervisors on all days of the month/year during the contract period including Sunday and Holidays so as to complaints are attended promptly within 02 hours so that health and life of troops and their families is not adversly affected.
M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
Excavation in trenches n exc 1.5m wide and n exc 1.50m in depth for foundation etc and getting out in soft/loose soil complete all as specified.
M&L for 200mm sail-glazed stoneware drain pipes laid in trenches and jointed complete all as specified and as directed.
Supply and laying, DWCPE(SN8) 200 mm dia pipes and snap fit coupler incl testing and laid properly, jointed laid in teenches to a level on concrete bed complete all as specified. .
M&L for Sand cushion under floors or in foundation including watering and consolidation.
M&L for cement concrete 1 : 4 : 8, type D2, using 40mm graded stone aggregates incl beding, packing under and haunching against the sides for 200mm internal dia of pipes, after they are laid and tested complete all as specified (thickness of concrete bed 100mm).
Returning filling in, incl spreading levelling watering and well ramming in layers n exc 25cm (after the pipes have been laid and tested) in soft/loose soil complete all as specified.
Removal of surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above starting point.
Demolation Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles all as specified .
M&L Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in Cm 1:6 all as specified and directed.
S & F in replacemen precast fibre reinforced cement concrete Manhole cover including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 450mmx450mmx50mm omplete all as specified and as directed.
S & F in replacemen precast fibre reinforced cement concrete Manhole/drain cover including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of overall Size 1000mmx500mm x50 mm omplete all as specified and as directed.
M&L for cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 or 3/4 section) in cement concrete 1 : 2 : 4 type B1 using 20mm graded stone aggregate finished smooth and reforming benching as required for 150mm dia pipes complete all as specified.
Dewatering/desludging of septic tanks, soakage wells etc of any depth, cleaning of all sludge, silt residue of both organic and inorganic nature by manual labour or by mechanical scrappers etc and disposal off the same out side the defence area all as specified and directed by Engr-in-Charge.
Mechanically used water fitting Hydraulic pressure machine and water sucking hydraulic pressure machine jet press for cleaning of sewage line shall be used by the contractor as per direction of Engineer-in-Charge as on required basis. Job shall be completed to the entire satisfaction of GE. (For 1WEC, EETSU AND WEE.)
M&L for cement concrete 1:3:6 type using 12.5 mm graded stone aggregate as in coping and similar work incl necessary form work to obtain a smooth finishes complete all as specified and as directed.
M&L PCC 1:4:8 type D2 using 40mm graded stone aggregates as in foundation complete all as specified and as directed.
S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamps etc including taking out/dismentling of old pipe complete all as specified.
S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls with clamps etc including taking out/dismentling of old pipe complete all as specified.
S&F in repair PVC (SWR) bends any radius, 110 mm bore complete.
S&F in repair PVC (SWR) bends any radius, 75 mm bore complete.
Supply and fix in replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, laid in trenches including excavation and PCC bedding and haunching in below ground level or in floors or fixed to walls with clamps etc, bore of pipe 75mm complete all as specified and directed.
Supply and fix in replacement of broken cast iron (sand cast) soil, waste and vent pipes in any length, with or without ears, with cement joints, laid in trenches including excavation and PCC bedding and haunching in below ground level or in floors or fixed to walls with clamps etc, bore of pipe 100mm complete all as specified and directed.
S&F in repair 100 mm bore cast iron bends complete all as specified and as directed.
S&F in repair 75 mm bore cast iron bends complete all as specified and as directed.
Demolition of reinforced cement concrete in any position all as specified and as directed by Engineer -in-Charge.
M&L for Reinforced cement concrete nominal mix 1:1.5:3 Type A-1 (20 mm graded agg) in roof of septic tanks & similar items complete all as specified and as directed by Engineer-in-Charge.
Use and waste of form work to soffits of suspended slabs such as roof slab, Chajja, platforms and landings etc not exc 200mm thick (horizontal or sloping) for fair finished surfaces of concrete complete all as specified and directed.
S&F TMT steel bars of 10 mm dia and over,cut to length bent to shape required, including cranking bending spirally for hopping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to. complete all as specified and as directed.
Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed.
M&L for Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or oloured cement to match incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) complete all as specified and as directed.
M&L for glazed ceremic colour tiles (600x300x7mm) thick, in vertical surface etc set and jointed in neat slurry and pointed in white or coloured cement to match with tiles including 10mm thick rendering in cement mortar (1:6) complete all as specified and as directed.
M&L for Non - skid Ceramiccolour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or oloured cement to match incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) complete all as specified and as directed.
S&F Non - skid Ceramic colour tiles 600 x600 x 7 to 8 mm thick in floors etc and 15mm thick screed bed 1:6 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified.
S&F Non - skid Ceramic colour tiles 600 x100 x 7 to 8 mm thick in vertical surfaces etc and 10mm thick screed bed 1:4 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified.
M&L for 18 -20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, walls, window- cills, cooking platforms and like in 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite.
Dismentling plain or corrugated steel sheeting any gauge thickness including nainital or similar pattern roof covering Complete all as specified and directed by Engineer-in-Charge.
S & F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws Complete all as specified and directed by Engineer-in-Charge.
Material and labour for rotational moulded polyethylene water storage tanks 500 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 25 mm dia brass float valve and polyethylene ball including taking out existing unserviceable overhead tank of any description.
Material and labour for rotational moulded polyethylene water storage tanks 1000 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 25 mm dia brass float valve and polyethylene ball including taking out existing unserviceable overhead tank of any description.
S&F flot valves 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 20mm-210 gms complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm complete all as specified and directed.
Supply and fix galvanized steel tubing, 15 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed.
Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 20mm complete all as specified and directed.
Supply and fix galvanized steel tubing, 20 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed
S & F in repairs 15 mm bore GI fittings such as union, Socket, Tee, Elbow, Nipple 4" 6", Reducer, Plug, and tank nipple complete all as specified and directed.
Demolition of brick work built in cement or cement lime mortar of any description including quoins,arches,pillars,etc., all as directed.
Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etc complete all as specified and directed.
M &L 15mm thick ready mix cement plaster with bulk density 1.4 to 1.70 Kg per Itr, water ration 17 to 19 % by weight with compressive str as per IS 4031 part 6 applied as per the manufactore instr including necessaery cement screed and prepartion of surface to received ready mix plaster. Complete all as specified and directed by Engineer-in-Charge.
M &L 10mm thick ready mix cement plaster with bulk density 1.4 to 1.70 Kg per Itr, water ration 17 to 19 % by weight with compressive str as per IS 4031 part 6 applied as per the manufactore instr including necessaery cement screed and prepartion of surface to received ready mix plaster. Complete all as specified and directed by Engineer-in-Charge.
M &L 5mm thick ready mix cement plaster with bulk density 1.4 to 1.70 Kg per Itr, water ration 17 to 19 % by weight with compressive str as per IS 4031 part 6 applied as per the manufactore instr including necessaery cement screed and prepartion of surface to received ready mix plaster. Complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of cement base paint complete all as specifed as direted by Engr-in-charge.
M & L for applying two coats of oil bond destember over one coat of birla white wall care putty on newly plastered surfaces(internal) of walls complete all as specified and directed.
M&L preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of old decorated plastered surfaces of ceiling including pilasters and cornices etc , brooming down, etc and applying one coat of white washing complete all as specified and as directed.
M&L for old decorated surfaces plastered or unplastered surface of wall and applying two coat of oil bond distemper on wall complete all a spcefied.
M&L for preparation of old decorated plastered surfaces of walls, brooming down,washing with water etc and applying two coat of cement based paint complete all as specified and as directed.
M & L for preparation of old plastered surfaces of walls removal of surfaceing of existing layered of paint an and applying two coat of exterior emulsion acrylic weather coat paint (Apex) one coat of primer complete all as specified and directed.
Dismantling of wall and ceiling board fibre pulp AC boards etc any thickness including cover fillets removing the wiring and refixing the same including fixture as necessary at site including frame work.
M and L Providing & Fixing False ceiling with semi perforated 12mm thcik micro tegular edged at all heights with GRG (Glass Fibre reinforced Gypsum) false ceiling tiles of size 595x595mm of approved texture,design and pattern having moisture content less than 2%,humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 475 (part-4)-1970 and light Code Description unit rate No 429 SUB HEAD :26.0 NEW TECHNOLOGIES AND MATERIAL reflectance of 85% minimum to be laid in true horizoatal level suspended on interlocking metel T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanised @ 120 grams oer sqm including both sides) comprising of main-T runners of size 15x32mm of length 3000mm, vross-T of size 15x32nn of lenght 1200mm amd secondry itermediate cross-T of size 15x32 of lenght 600mm to form grid module of size 600x600mm, suspended from ceiling using galvanised mild steel items (galvanising @ 80 grams per sqm) ie. 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and L-shape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x24x0.40mm of length 3000mm to be fixed on perimeter wall/partition with the help of plastic rawl pluhs at 450mm center to center and 40mm long dry wall screws. The work shall be carried out as per specification, drawing and as per direction of the Engineer-incharge.
M&L for 18/19 mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice laminations , fixed with screws to timber frame work complete all as specified and as directed.
S&F for 19/20mm thick Block board grade 2 quality interrior grade commercial type fixed with screws to timber frame work including teak wood leaping and necessary rebating for double shutter where required (Note : teak wood leaping shall be measured and paid separatly).
S&F 6mm thick plywood grade BWR type BB of (5 Nos of ply) fixed with screws to timber frame work.
Supply only MS butt hinges medium weight 75 mm size fixed with MS screws.
S&F aluminium anodised barrel tower bolt extruded section 100 mm long and fixed with MS screws.
S&F 100 mm extruded aluminium alloy handle anodised fabricated type and fixed with mS screws.
S&F continuous (Piano) hinges, mild steel bright finish or electro glavanised (width of flap when open 30mm).
S&F 40mm dia cupboard knobs fixed with nut screw and washer of mild steel, bright finished.
M&L second class hard wood timber scantling plain fillets, square, rectangular or triangular in section clear swan, sectional area exc 6 sqcm & not exc 13 sqcm, secured with nails or brads.
Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame).
Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame).
Taking down shutters of any discription exceeding 1 sqm each and not exceeding 2 sqm each.
M&L Mild steel frame work as in door chowkhats with angle iron welded together ends of angle shouldered and fixed to opening and welding 3 Nos mild steel butt hinges 100 mm size, and 6 nos hold fasts made out of FI 25x3 mm 30 cm long for fixing of chowkhats( Butt hinges paid sep) all as spd.
S & F Pressed steel frames box type made of 1.25 mm thick MS Sheet double rebates of size 125x60mm for doors, ventilator with double rebates including necessary fixing lugs, hinges, lock strike plate etc, incl PCC 1:2:4 type B1 (using 20mm graded stone agg) to fill the frame & making good complete all as specified & directed by Engr-in-Charge.
S & F Pressed steel frames box type made of 1.25 mm thick MS Sheet single rebates of size 105x60mm for doors, ventilator including necessary fixing lugs, hinges, lock strike plate etc, incl PCC 1:2:4 type B1 (using 20mm graded stone agg) to fill the frame & making good complete all as specified & directed by Engr-in-Charge.
S&F 30 mm thick 2nd class hard wood glazed and skelton shutter devided into square with plain, chamferred or rounded sash bar and fitted with cut and mitred beads for securing glass, size of members as per SSS Part - I section 8 clause 8.24 (b).
S&F 30MM thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and as directed.
M & L for 35 mm thick factory made 2nd class hardwood plain, framed, panelled shutters (two panels), with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces. the size of rail and stile as per IS:1003 (Part-I) kiln seasoned and chemically pressure treated.
M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
S & F Steel window (Factory made) double rebate, with side hung, shutter incl hinges, tower bolt, steel handle and peg stay complete with glaze and gauge shutters (both are complete) devotailed or welded including making good to cutting holes with PCC 1:2:4 complete all as specified .
S&F solid PVC door frame of size 50 x 47 mm made out of 5mm plain colour PVC sheet re-inforced with MS square tube, supplying and fixing in opening as per manufacturers instructions drawings and specifications.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F MS butt hinges medium weight 100 mm size fixed with MS screws.
S&F aluminium anodised barrel tower bolt extruded section 150 mm long and fixed with MS screws.
S&F 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with mS screws.
S&F 300 mm extruded section aluminium alloy anodised, sliding door bolt with hasp and staple and fixing clip of sheet and fixing bolt and nut.
Dismantling wrought iron or mild steel work of any description such as guard bars, grills etc.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks, roof truss, iron sheet and similar work con- forming to Fe.290.Gde-E-165
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
S & F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.50 sqm in each pane complete all as specified and directed.
S&F Cequered cement concrete tiles with grey cement and pigment 30cm X30cm X20mm thick set jointed and pointed in neat cement slurry in floors and incl 15mm thick screed bed in CM 1:6 all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block 60mm thick M-35 grade any shape and size with grey cement and pigment complete all as specified and as directed.
S&F in repairs stainless steel plate rack of size 90x80x25 cm depth size made out of 0.80mm thick sheet complerte all as specified and directed by Engineer-in-Charge.
Material and labour for welding in repairs not exc 2.5 cm in length complete all as directed
Supply and fix in repairs PVC low level white flushing cistern valveless syphonic action type 10 lts capacity IS marked with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC,(ISI Marked) complete all as specified all as specified.
Supply and fix in repairs vitreous china wash hand basin (flat back) white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper including a pair of mild steel angle iron brackets of suitable size and waste pipe & waste fittings complete all as specified.
S & F in repair Glass Corner Shelf 6mm thick including CP railing radius 250mm complerte all as specified and directed by Engineer-in-Charge.
S&F in repairs Glass shelf assembly 5.5mm thick, 600mm long 120mm wide with cp railing complerte all as specified and directed by Engineer-in-Charge.
S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified.
S&F in repairs angle valve, fancy type, chromium plated brass, 15mm, complete all as directed.
Supply only 15 mm dia pillar taps, fancy type brass with capstan head chromium plated screwed down high pressure with or without lettered “hot/cold” with long screwed shank and flynut screwed.
S&F in repair stainless steel gratings 100mm bore size fixed with cement motar.
S & F in repair towel rail 600mm long brass chromium plated of 20mm dia (external) and 1mm thickness with gutties embeded in cement mortar 1:3 with MS screws etc complete all as specified and directed.
Demolition of concrete and pavings n.exc 15 cm thickness (below or above ground level)
M&L for cement concrete 40mm thick type B-1, 1:2:4 (using 20 mm graded aggregate) as in floor for fair finished surfaces of concrete complete all as specified and directed.
M&L for cement concrete 75mm thicktype C-2 1:3:6 (40mm graded aggregate)as in plinth protection and paths laid in alternative panel.
M&L earthing with galvanized steel earth plate 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 40 mm bore for protection of G.I. strip from earth electrode to the Main switch/Distribution Board, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 (20 mm graded stone aggregate) reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, GI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recessed or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc 4 mm dia galvanised or steel wire complete all as specified.
Taking down carefully unserviceable distribution boards including disconnecting of incoming and outgoing connections complete all as specified and directed.
Supply and fix MCB DB SPN 8 way in replacementHorizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in replacement MCB SPN 40 to 63 Amp Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge.
Supply and fix in replacement MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge .
Supply and fix in replacement Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through metallic/ non metallic conduit in walls all as specified and as directed.
Supply and fix in replacement Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through metallic/ non metallic conduit in walls all as specified and as directed.
Supply and fix in replacement Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through metallic/ non metallic conduit in walls all as specified and as directed.
Supply and lay cable in replacement XLPE insulated screened PVC bedded, galvanized steel strip and wire armoured , electric power cables (heany duty) 1100 volts grade with stranded alumimium conductor of size 25 Sqmm 3.5 core.
S&F in repairs steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm complete all as specified and directed.
S&F in repairs 3mm thick sheet glass ordinary quality and galzing with oil putty in square n exc 0.50 sqm in each complete all as specified and directed.
Schedule of Credit
imran construction company
GIAN ENGINEERS
a.k constructions
M/S ANIL KUMAR
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .