Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L1 | Accepted-AOC Being Lowest bidder after deucting the sch of credit Rs 156540.00 | |
| 2 | L2₹15.7 L+₹25,980 (1.68%)Rejected-AOC WARD NO 1 HOUSE NO 04 SUBASH NAGAR UDHAMPUR 182101 J K | UDHAMPUR | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L2 | Rejected-AOC 2nd Lowest bidder after deucting the sch of credit Rs 156540.00 | |
| 3 | L3₹16.8 L+₹1.3 L (8.17%)Rejected-AOC NEAR INDUSTRIAL ESTATE THANDA PADDAR UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L3 | Rejected-AOC 3rd Lowest bidder after deucting the sch of credit Rs 156540.00 | |
| 4 | L4₹22.1 L+₹6.6 L (42.9%)Rejected-AOC CHHURTA JHAJJAR KOTLI JAMMU J K 181222 | 181222 | L4 | Rejected-AOC 4th Lowest bidder after deucting the sch of credit Rs 156540.00 | |
| 5 | L5₹24.2 L+₹8.8 L (56.6%)Rejected-AOC SHOP NO 82 6 TRANSPORT NAGAR NARWAL JAMMU 180004 | JAMMU | JAMMU | J K | 180004 | L5 | Rejected-AOC 5th Lowest bidder after deucting the sch of credit Rs 156540.00 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
15 Nov 2021, 6:00 pmClosed
GE Army Dhar Road Udhampur
GE Army Dhar Road Udhampur
REPAIR AND MAINTENANCE OF PUMP, MOTORS, STARTER, DOZER, CHLORINATION PLANT, CLEANING OF SUM/OH TANK AND OTHER CONNECTED WORKS AT JINDRAH UNDER GE (ARMY) DHAR ROAD
2021_MES_480784_2
8067/NIT-51/2021-22
Open Tender
Miscellaneous Works
Item Rate
180 days
Jindrah under GE Army Dhar Road Udhampur
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE Army Dhar Road Udhampur
₹50,000
Yes
10 May 2022
1 Nov 2021
17 Nov 2021
1 Nov 2021
15 Nov 2021
1 Nov 2021
1 Nov 2021 - 1 Nov 2021
Amount
Taking proper shut down in writing disconnecting all the electrical connections, dismantling the unserviceable motor any type centrifugal motor with pump from the base plate and pump and shifting the same to approved workshop for repair/rewinding. Dismantling the motor, cutting and removing the old heated up/burnt winding of the stater /rotor, cleaning the slots and replacement of brunt spare parts and reassembling the motor including transportation back the same after rewinding and reassembling, for size of electric motor 50 to 75 HP complete all as specified and directed by Engr -in- Charge. Note:- (a) Rewinding of motor will be measured and paid separately under relevent item. (b) The motor shall be squirrel cage induction/slipring induction motor. (c) The contractor shall reinstall the motor within one week after handing over for repairs failing which a penalty @ Rs. 1000/- per day of delay will be charged from the contractor. (d) The rates quoted shall be deemed to include the cost of loading/unloading, transportation, grease, nuts, bolts and washers of any size and shape as required at site and refixing of motor duly functional and testing at its original location/position complete all as specified and directed. (e) Replacement of unserviceable bearings and greasing them completely. Bearing shall shall be measured and paid separately. (f) Motor shall be dismantled at workshop in presence of JE concern and inspected by the Engineer -in-Charge. A repair note shall be prepared by the contractor which shall be signed by contractor, JE, EIC and counter signed by GE. Winding cut shall be made in presence of EIC.
Taking proper shut down in writing disconnecting all the electrical connections, dismantling the unserviceable motor any type centrifugal motor with pump from the base plate and pump and shifting the same to approved workshop for repair/rewinding. Dismantling the motor, cutting and removing the old heated up/burnt winding of the stater /rotor, cleaning the slots and replacement of brunt spare parts and reassembling the motor including transportation back the same after rewinding and reassembling, for size of electric motor 30 to 40 HP complete all as specified and directed by Engr -in- Charge. Note:- (a) Rewinding of motor will be measured and paid separately under relevent item. (b) The motor shall be squirrel cage induction/slipring induction motor. (c) The contractor shall reinstall the motor within one week after handing over for repairs failing which a penalty @ Rs. 1000/- per day of delay will be charged from the contractor. (d) The rates quoted shall be deemed to include the cost of loading/unloading, transportation, grease, nuts, bolts and washers of any size and shape as required at site and refixing of motor duly functional and testing at its original location/position complete all as specified and directed. (e) Replacement of unserviceable bearings and greasing them completely. Bearing shall shall be measured and paid separately. (f) Motor shall be dismantled at workshop in presence of JE concern and inspected by the Engineer -in-Charge. A repair note shall be prepared by the contractor which shall be signed by contractor, JE, EIC and counter signed by GE. Winding cut shall be made in presence of EIC.
Taking proper shut down in writing disconnecting all the electrical connections, dismantling the unserviceable motor any type centrifugal motor with pump from the base plate and pump and shifting the same to approved workshop for repair/rewinding. Dismantling the motor, cutting and removing the old heated up/burnt winding of the stater /rotor, cleaning the slots and replacement of brunt spare parts and reassembling the motor including transportation back the same after rewinding and reassembling, for size of electric motor 10 to 20 HP complete all as specified and directed by Engr -in- Charge. Note:- (a) Rewinding of motor will be measured and paid separately under relevent item. (b) The motor shall be squirrel cage induction/slipring induction motor. (c) The contractor shall reinstall the motor within one week after handing over for repairs failing which a penalty @ Rs. 1000/- per day of delay will be charged from the contractor. (d) The rates quoted shall be deemed to include the cost of loading/unloading, transportation, grease, nuts, bolts and washers of any size and shape as required at site and refixing of motor duly functional and testing at its original location/position complete all as specified and directed. (e) Replacement of unserviceable bearings and greasing them completely. Bearing shall shall be measured and paid separately. (f) Motor shall be dismantled at workshop in presence of JE concern and inspected by the Engineer -in-Charge. A repair note shall be prepared by the contractor which shall be signed by contractor, JE, EIC and counter signed by GE. Winding cut shall be made in presence of EIC.
Taking proper shut down in writing disconnecting all the electrical connections, dismantling the unserviceable motor any type centrifugal motor with pump from the base plate and pump and shifting the same to approved workshop for repair/rewinding. Dismantling the motor, cutting and removing the old heated up/burnt winding of the stater /rotor, cleaning the slots and replacement of brunt spare parts and reassembling the motor including transportation back the same after rewinding and reassembling, for size of electric motor 5 HP complete all as specified and directed by Engr -in- Charge. Note:- (a) Rewinding of motor will be measured and paid separately under relevent item. (b) The motor shall be squirrel cage induction/slipring induction motor. (c) The contractor shall reinstall the motor within one week after handing over for repairs failing which a penalty @ Rs. 1000/- per day of delay will be charged from the contractor. (d) The rates quoted shall be deemed to include the cost of loading/unloading, transportation, grease, nuts, bolts and washers of any size and shape as required at site and refixing of motor duly functional and testing at its original location/position complete all as specified and directed. (e) Replacement of unserviceable bearings and greasing them completely. Bearing shall shall be measured and paid separately. (f) Motor shall be dismantled at workshop in presence of JE concern and inspected by the Engineer -in-Charge. A repair note shall be prepared by the contractor which shall be signed by contractor, JE, EIC and counter signed by GE. Winding cut shall be made in presence of EIC.
Dismantling unsv motor including all the insulating materials i.e varnish, cotton tape, insulating paper and soldering etc of motor capacity 75 to 40 HP and rewinding the motor rotor with super enamelled copper winding wire/strip as per existing size and truns etc complete all as specified and directed by Engr-in-Charge.Note:- (a) Winding cut shall be made in presence of EIC and reassembling shall be done after inspection by the EIC. (b) Rewinding wire, varnish, cotton tape insulating paper etc will be measured and paid separately under relevent item. (c) The motor shall be squirrel cage induction/slipring induction motor.
Dismantling unsv motor and Rewinding the motor rotor with super enamelled copper winding wire/strip as per existing size and truns etc including all the insulating materials i.e varnish, cotton tape, insulating paper and soldering etc of motor capacity 30 to 15 HP complete all as specified and directed by Engr-in-Charge.Note:- (a) Winding cut shall be made in presence of EIC and reassembling shall be done after inspection by the EIC. (b) Rewinding wire, varnish, cotton tape insulating paper etc will be measured and paid separately under relevent item. (c) The motor shall be squirrel cage induction/slipring induction motor.
Dismantling unsv motor and Rewinding the motor rotor with super enamelled copper winding wire/strip as per existing size and truns etc including all the insulating materials i.e varnish, cotton tape, insulating paper and soldering etc of motor capacity 10 to 5 HP complete all as specified and directed by Engr-in-Charge.Note:- (a) Winding cut shall be made in presence of EIC and reassembling shall be done after inspection by the EIC. (b) Rewinding wire, varnish, cotton tape insulating paper etc will be measured and paid separately under relevent item. (c) The motor shall be squirrel cage induction/slipring induction motor.
Rewinding the motor stator with super enamelled copper winding wire of existing size and gauge and truns etc including all the insulating materials i.e varnish with suppr high quality of cotton tape, insulating paper and other misc items of motor any capacity all as specified and directed by Engr-in-Charge.Note:- (a) Winding cut shall be made in presence of EIC and reassembling shall be done after inspection by the EIC. (b) The motor shall be squirrel cage induction/slipring induction motor.
M&L for cleaning of semi under ground sump by scraping/removing all funges, scales, dust, sludge etc from inside of the semi under ground tank and depositing the same to a distance exc 50 mtrs and n.exc. 100 mtrs including washing the walls & bottom of the over head tank with water and disinfection chemical such as bleaching powder etc and writing date of cleaning, CA No and name of contractor with synthetic enamel black/white paint complete for 100000 gallons capacity complete all as specified and directed. (Kali Mata tank)
M&L for cleaning of under ground sump by scraping/removing all funges, scales, dust, sludge etc from inside of tank and depositing the same to a distance exc 50 mtrs and n.exc. 100 mtrs including washing the walls & bottom of the tank with water and disinfection chemical such as bleaching powder etc and writing date of cleaning, CA No and name of contractor with synthetic enamel black/white paint complete for 40000 Ltrs capacity complete all as specified and directed. (Gandira)
All as per item No 10 above but of capacity 35000 ltr (Location -Gandira)
All as per item No 10 above but of capacity 10000 Ltrs (Location Tawi pump house -02 Nos and Bansoo pump house.
All as per item No 10 above but of capacity 50000 Ltrs (Location Post-12 Nos pump house
All as per item No 10 above but of sedimentation tank capacity 30000 Ltrs (Location-12 No pump house )
All as per item No 10 above but of capacity 1,25,000 Ltrs (Location-Booster pump house)
All as per item No 10 above but of capacity 1,12,500 Ltrs (Location-Booster pump house)
All as per item No 10 above but of capacity 2,25,000 Ltrs (Location-Booster pump house clearifluctor tank)
All as per item No 10 above but of SMC Tank capacity 50000 Ltrs (Location-Bansoo pump and Ghandira Terra Top)
Scrapping, Preparation and painting of surface of siluce valve/air valve/NRV any size 50 mm to 150 mm bore and applying one coat of synthetic enamel paint of black colour complete all as specified and directed by Engr-in-Charge
Supply and fixing in replacement of sets of bearings for 5 to 15 HP H.P motor of end carriage drive complete all as specified and directed.
All as per item No 20 above but bearing for 20 to 30 HP pump/motor
All as per item No 20 above but bearing for 40 to 75 HP pump/motor
Supply and fixing star rubber coupling. Make : Lovejoy L-190.
Supply and fixing Pump seal. Make : Champion.
Supply and fixing bearing sleeves.
Overhauling and repairing and servicing for Impeller of suitable existing size made of brass/CI complete all as specified and directed at site by engr-in-charge.
M&L for structural work fabricated from structural , steel section including nut, bolts, washers including cutting/ welding in any position, any shape and drilling hole for bolts in any size and shape as per site requirement or as directed and inclusive of one primer coat of red oxide and one finish coat of synthetic enamel black paint including welding work for repair of SMC tank structure complete all as per specified and directed.
Supply & fixing in replacement of old unsv starter by Automatic Star Delta starter consisiting of ampmetre,voltmetre,indicator lamp,ON/OFF push button,TP MCB etc suitable for motor pump set of capacity 75 H.P. including making all electric connection complete all as specified. Make - Havells Cosmic star / C&S/Bentex/ L&T/BCH as approved by GE
Supply & fixing in in replacement of old unsv starter by Automatic Star Delta starter consisiting of ampmetre,voltmetre,indicator lamp,ON/OFF push button,TP MCB etc suitable for motor pump set of capacity 40 H.P. including making all electric connection complete all as specified. Make - Havells Cosmic star / C&S/Bentex/ L&T/BCH as approved by GE
Supply & fixing in replacement of old unsv starter by Automatic Star Delta starter consisiting of ampmetre,voltmetre,indicator lamp,ON/OFF push button,TP MCB etc suitable for motor pump set of capacity 20 H.P. including making all electric connection complete all as specified. Make - Havells Cosmic star / C&S/Bentex/ L&T/BCH as approved by GE
Supply & fixing in replacement of old unsv starter by Automatic Star Delta starter consisiting of ampmetre,voltmetre,indicator lamp,ON/OFF push button,TP MCB etc suitable for motor pump set of capacity 10 H.P. including making all electric connection complete all as specified. Make - Havells Cosmic star / C&S/Bentex/ L&T/BCH as approved by GE
Repair and Maint of automatic star delta starter, decarbonised of all contects, relay,thimbles etc and cleaning, making good, lightening of all cables, wires and other connected items, oiling in moving machenisim etc incl replacement of burnt parts as per requirment basis all as specified and directed for 75 starter complete all as specified and directed .
Repair and Maint of automatic star delta starter, decarbonised of all contects, relay,thimbles etc and cleaning, making good, tightning of all cables, wires and other connected items oiling in moving macnisiam etc incl replacement of burnt parts as requirment basis all as specified and directed for 50HP starter complete all as specified and directed .
Repair and Maint of automatic star delta starter, decarbonised of all contects, relay,thimbles etc and cleaning, making good, tightning of all cables, wires and other connected items oiling in moving macnisiam etc incl replacement of burnt parts as requirment basis all as specified and directed for 40 to15 HP starter complete all as specified and directed .
Supply only Flat water proof submersible cable 3 core copper conductor, PVC insulated 1100 volts grade stranded 10 Sqmm , ISI marked and connected to pump motor through water tight sealing joints complete all as specified. Make: National Cables / Finolex / Havell's/Plaza
Supply & Fixing ML - 3 Type three Pole Power contactor having 02 NC & 02 NO auxilary contacts, AC operated of coil voltage 230 Volt, 50 Hz AC 3 rating 40 A, ACI Rating 45A complete all as specified and directed.Cat no. SS90721 of Make - L&T or its equivalent in Havells/ Legrand/Schneider as approved by GE
Supply & Fixing ML - 4 Type three Pole Power contactor having 02 NC & 02 NO auxilary contacts, AC operated of coil voltage 230 /415 Volt, 50 Hz AC 3 rating 70 A, ACI Rating 100A Cat No. SS90910 of Make - L&T or its equivalent in Havells/ Legrand/Schneider as approved by GE
Supply & Fixing in replacement of weighted Suction Line Strainer 3/8 '' suitable forcalcium hypochloride Dosing Pump complete all as specified.
Supply & Fixing in replacement of Injection Check valve 3/8 ''suitable for calcium hypochloride Dosing Pump complete all as specified.
Supply & fixing in repair of digital panel mounted AC Amp meter, three phase in 96 x 96 mm square size, flush mounted case, accuracy class - 0.5 incl current transformer suitable size complete all as specified and directed .
Supply & fixing in repair of digital panel mounted AC Volt meter , three phase in 96 x 96 mm square size, flush mounted case, accuracy class - 0.5 complete all as specified and directed .
Supply & fixing in repair of Analog panel mounted AC Amp meter , three phase in 96 x 96 mm square size, flush mounted case, accuracy class - 0.5 incl current transformer suitable size complete all as specified and directed .complete all as specified and directed .
Supply & fixing in repair of Analog panel mounted AC Volt meter , three phase in 96 x 96 mm square size, flush mounted case, accuracy class - 0.5 complete all as specified and directed .
Servicing , repairing and over hauling of flaculator including replacement of chain and gear box including oiling greasing and making good as serviceable condition all as specified and directed ( Note :- repairing of flaculator for both tank sedimentation and pre sedimentation tank seperatly)
Servicing repairing and over hauling of slip ring for flaculator all as specified and directed.
Painting and Preparation of surface of steel section incl complete moving bridge and structure of clarifloculator tank and applying two coat after rubbing of rusted surface of synthetic enamel paint including marking all sign of requisite colour complete all as specified and directed by Engr-in-Charge
Repairing of clarifloculator rubber pading (wheel), bearing, chain, motor and overhauling complete and cleaning well mentained all as specified and directed Note rubber padding taken seperately
Replacement of rubber padding of clarifloculator all as specified and directed
Painting of pump motor set, pump etc of applying two coats of synthetic enamel paint after rubbing of rusted surface including marking all sign of requisite colour complete all as specified and directed by Engr-in-Charge
PCC (1:4:8) type D-2 using 40mm graded aggregate as in foundation filling, mass concrete for foundation of motor, pump, header etc complete all as specified and directed.
PCC (1:3:6) type C-2 using 40mm graded aggregate as in foundation filling mass concrete for foundation of motor, pump, header etc complete all as specified and directed.
PCC (1:2:4) type B-1 using 20mm graded aggregate as in coping of motor, pump, header etc, including necessary form work complete all as specified and directed
S&F in replacement of double flanged sluice valve of size 80 mm bore class PN 1.6 confirming to IS 14846/2000 with stainless steel spindle including replacement of worn out rubbersheet nuts, bolts and washers complete all as directed
S&F in replacement of double flanged sluice valve of size 150 mm bore class PN 1.6 confirming to IS 14846/2000 with stainless steel spindle including replacement of worn out rubbersheet nuts, bolts and washers complete
S&F in replacement of double flanged sluice valve of size 100 mm bore class PN 1.6 confirming to IS 14846/2000 with stainless steel spindle including replacement of worn out rubbersheet nuts, bolts and washers complete
S&F in replacement of double flanged sluice valve of size 50 mm bore class PN 1.6 confirming to IS 14846/2000 with stainless steel spindle including replacement of worn out rubbersheet nuts, bolts and washers complete
M&L GI flange joint 150 mm bore 6/8 holes with rubber packing ring using suitable size nuts, bolts and washers, welding work complete to join two pipe all as specified and as directed .
All as per item No 57 above but 100 mm bore complete all as specified and directed
All as per item No 57 above but 80 mm bore complete all as specified and directed
S&F in replacement of double flanged Non return valve of size 150 mm bore including replacement of worn out rubbersheet nuts, bolts and washers complete.
S&F in replacement of double flanged Non return valve of size 100 mm bore including replacement of worn out rubbersheet nuts, bolts and washers complete.
S&F in replacement of Air release valve of size 150mm double flanged including taking down old unserviceable complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed
Taking out old existing GI water tubing lines and connected unserviceable pipe and fitting includidng segregation of serviceable pipe and fittings and keep in safe custody and reuse serviceable pipe line and fitting from trench/ in ground/under road /under PCC path etc the site of work complete all as specified and as directed of the 150 mm dia bore size :- Note : Earth work shall be measured & paid separatly.
M&L for GI water tubing medium grade and laid in trenches/floors with running fittings complete all as specified and directed of size 150mm :-Make of GI Water Tubing medium grade - TATA/JINDAL/SURYA PRAKASH/BST., Make of GI FITTINGS- Only ISI marked Fittings.Including 150mm Flange Joint set.
M&L for gland packing with suitable size to stuffing box of pump of any capacity and make the box leak proof complete all as specified.
M&L for cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of GI Pipe/Cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
Supply and fixing in replacement of MCCB 400 Amps 4 Pole, 35 KA, 415 V, 50 Hz complete all as specified and directed. Make : Legrand/Schenider (Electric)/L&T/Havells
Supply and fixing in replacement of MCCB 250 Amps 4 Pole, 25 KA, 415 V, 50 Hz complete all as specified and directed. Make : Legrand/Schenider (Electric)/L&T/Havells
Supply and fixing in replacement of MCCB 160 Amps 4 Pole, 25 KA, 415 V, 50 Hz complete all as specified and directed. Make : Legrand/Schenider (Electric)/L&T/Havells
Supply and fixing in replacement of MCCB 100 Amps 4 Pole, 16 KA, 415 V, 50 Hz complete all as specified and directed. Make : Legrand/Schenider (Electric)/L&T/Havells
M&L for cleaning of filter bed of MS tank and replacement of filter bed media from chamber at filteration plant Jindrah including draining out muddy water from tank and removing all other foreign material like scales, sludges, silt etc and depositing where directed and cleaning tank by washing soda scrapping internal wall surface of water tank using hair brush and wooden blades , including changing of gravels by removing old utilised gravel complete all as directed by Engr-in-Charge.
Excavation in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth, getting out in hard/dense soil for stay assembly/laying of cable/errection of poles etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick.
Removing of excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point.
M&L for dry sand cushioning in trenches for protection of cable including watering and consolidation all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
M&L for well burnt bricks sub class 'B' old size laying in trenches perpendicular to axis of the cable complete all as specified and directed.
Taking out existing worn out/old PVC insulated cable of 95 Sqmm 3.5 core size of 1100 Volt grade in pieces from trenches making loop for transportation and removal from site after taking proper shut down from MES competent staff complete in all respect and as directed at site.
Material and labour for fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board, 1100 volts grade heavy duty cable with PVC insulated, stranded, aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 95 Sqmm 3.5 core with required aluminium cable lugs all as specified and directed. Make of Cable : Havells, Polycab, Gloster,Finolex
M&L for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 3.75 M deep below normal ground level) with top edge of the plate not less than 3.15 M below normal ground level, connected to galvanized earth strip 32mmx6mm by means of bolts, nuts, check nuts and washers of galvanised iron including necessary excavation and earth work ,PCC pit chamber in PCC (1:3:6) type C-1 using 20 mm graded aggregate with 50 mm thick pre-cast RCC cover in (1:2:4) type B-1 using 20 mm graded stone aggregate, reinforced with 8 mm dia bar@75mm c/c both way with two Nos lifting handles of 12 mm dia mild steel plain bar, funnel with wire mesh, lugs, 50mm dia galvanised iron protection pipe light grade ,watering pipe of size 20 mm dia galvanised iron light grade, main Earthing strip upto 7.5M including charcoal dust, common salt etc all as shown in electrical plate No. 3 of SSR Part-I 2009 including testing on completion complete all as specifed and as directed.
Repairing, greasing of butter fly valve of filter bed and necessary repair. Note:- Spare item required for necessary repair deemed to be included in quoted rates
Supply and fixing sign board 1 mtr x 2 mtr x 100 mm thick size MS box made out of 1.6 mm thick sheet incl painting two coats over one coat of primer with acrylic front sheet cover in blue colour including beading around the board and letter stricker paste of radium white colour i.e location name of installation etc incl 75 x 75 x 5 mm Ms angle 3 Mtr long fixing of board and PCC 1:3:6 300 x 300 x 300 mm upto ground level burried into ground incl painting with black enamelled paint directed font size at site.
DAVINDER SINGH
K S BUILDERS
MandeepConstructionCo
Balbir Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .