Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.9 LAccepted-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹17.8 L+₹85,345 (5.05%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L2 | Rejected-Finance Rejected. Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹35,800
Closing Date
19 Dec 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer MAF Jalahalli
Garrison Engineer MAF Jalahalli Bangalore 560013
8725PROVN OF CERTAIN MINOR REV WORKS UNDER AGE E M OF GE M AF STATION JALAHALLI BANGALORE
2022_MES_564640_1
8725/E8
Open Tender
Electrical and Maintenance Works
Item Rate
122 days
Garrison Engineer MAF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE AF MAINT PUBLIC FUND ACCOUNT
₹35,800
25 Feb 2023
22 Nov 2022
21 Dec 2022
22 Nov 2022
19 Dec 2022
6 Dec 2022
22 Nov 2022 - 29 Nov 2022
Amount
Material and labour for Ductile Iron Pipe(DI Pipes) S/S including special Class K-7,100 mm dia laid in trenches complete all as specified and directed.
Supply and lay pipe galvanized, “Medium class”, including fittings 80 mm dia complete all as specified and directed.
Material and labour for DI fittings/specials 100 mm to 300 mm dia suitable for spigot and socket end or flanged end such as bends (any type, radius and angle) tapers any type ( straight, bend, increasing, decresing or double socket etc.) Tee pieces single branch."Y" junction, double branch, cross, collars, caps and plugs, connecting pieces (any type) and tesing complete all as specified and as directed.
Material and labour for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot,drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint all as specified and as directed.
Material and labour for Cutting/drilling the existing Cast Iron/Ductile Iron pipes lines of 150/100 mm dia, in position for inserting of news Tees, branches, water meter, Sluice valve etc including excavation, returning, filling, removing complete all as specified and directed.
Excavation in trenches for laying under ground cable, errection of poles and stays, for laying of CI/DI/GI pipes in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed by Engr–in–charge.
Returning, filling in soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm in any type of soil complete all as specified and as directed.
Removing the excavated soil to a distance not exe 50 m and depositing where directed at a level n exe 1.5 m above the starting point all as direced.
Supply and Fix Sluice valves Class PN 1.6, 100 mm dia, conforming to IS-13095, fixing of GI/CI/DI water supply mains complete all as specified and directed.
All as per item No 09 above but of size 80 mm dia
Material and labour for construction of PCC block walling valve pit of size 900mmx 900mm x900mm(internal dimension) with precast cement concrete block of PCC 1:3:6 type-C-1 using 20mm graded stone aggregate and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces with and incl 40x40x6 mm mild steel angle iron frame and 3mm thick MS sheet cover thickness not less then 3mm with locking arrangement and 1 No 50 mm size 4 level lock with key in duplicate incl painting to steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide primer complete all as specified and shown on drawing complete all as specified and directed.
Cutting the existing road/hard standing/chequered cement concrete tiling/PCC flooring etc, not exceeding 700mm wide and 1100mm depth, for laying CI/GI/DI pipe line complete including taking online permission from BWSSB if civil road involves all as specified and as directed.
Material and labour for Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation complete all as specified and as directed.
Supply and fix water meter Brass suitable for 100 mm dia pipe with accuracy (+) or (-) 2% and having magnetic drive, hermetically sealed totaliser retrofittable for pulse out put, suitable for load water up to 30% for use in drinking watre with Flanged End Connection complete all as specified and directed by Engr-in charge.
Material and labour for construction of PCC block walling valve pit of size 1000mmx 1000mm x600mm(internal dimension) with precast cement concrete block of PCC 1:3:6(PCC 1:3:6) type-C-1 using 20mm graded stone aggregate and 10 mm thick rendering in CM 1:4 on internal and exposed external surfaces with and incl 40x40x6 mm mild steel angle iron frame and 3mm thick MS sheet cover thickness not less then 3mm with locking arrangement and 1 No 50 mm size 4 level lock with key in duplicate of incl painting to steel and iron surfaces with two coats of black bituminous paint over a coat of red oxide prime complete all as specified and shown on drawing complete all as specified and directed.
Supply and laying of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoued, electric power cable (heavy duty) 1100 volts grade with stranded aluminimum conductor of size 70 sqmm 3.5 core laying in trenches / cable ducts, fixed to wall /pole complete all as specified .
All as per item No.16 above but of size 10 Sqmm 4 core.
All as per item No.16 above but of size 6 Sqmm 2 core.
Returning and filling of trenches in two parts (i) using riddled soil obtained from excavated soil upto depth of 30 cm (8 cm below cable and remaining above cable) for cushioning of cable and (ii) refilling the trench of remaining depth with normal excavated soil all as specified and directed. Note :- Excavated soil shall shall be riddle by using sieve to separate composite particles etc as per IS 1255-1983 and refilling in trenches all as in cable cushioning.
Material and labour for Bricks (Size 0.23x 0.115x 0.075mm) covering width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed by Engr in charge.
Material and labour for Boring of holes under road, pavement, hard,standing by trenchless technology using ultra sounding technique and necessary, machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.
Supply & laying 80 mm bore galvanized steel tubing "light grade" with GI fittings in trenches/ under roads/ along pole/ wall for cable protection all as specified & directed by EIC.
Supply and fix MCCB TPN 100 A, 4 P, 415 V, 10-16 KA in existing panel.
Material and labour for UG cable route indicator made out of 100 mm dia MS plate with 20 mm dia 50cm long MS bar as legs for writing LT and name of feeder fixing with and including necessary PCC 1:2:4 in grouting route all as directed by Engr in Charge.
Supply and fixing fedder piller box made out of 16 gauge MS sheet and mounted on 40 x 40 x 5 mm angle iron four legs of suitable height front and back opening double door with proper locking arrangement weather proof out door type duly powder coated and grouting in ground with suitable PCC and comprising of the following :- (a) MCCB 4 pole, 100 A 35 KA ,430 V- 03 Nos. (b) Change over Switch front operated 4 P, 100 A-01 Nos (c) Indicator lamp (RYB) -01 set (d) four strip Copper bus bar 150 A- 01 Set (e) Multi functional meter -01 Nos (f) MCB TPN 63 A , 415 V -02 Nos
Supply and fixing the sheet metal enclosure MCB DB, SPN 240 Volts, 4 Way double door type grouting in wall with suitable pcc, Making good of disturbed surfaces and matching with existing surface including provn of suitable weather proof meter box and electrical connections complete all as directed.
Supply and fixing Isolator TPN 63 A , 415 V.
Material and labour for concealed sub main wiring with two runs of single lcore 2.5 sqmm flame retardant PVC insulated unsheat hed multi stranded copper conductor 650/1100 V grade with colour code and one run of 2.50 sqmm single core Flame retardant PVC insulated unsheathed multi stranded copper conductor green colour cable as earth continuity conductor drawn in PVC conduit with accessories all as directed and specified .(Note : Two runs of 2.5 sqmm copper cable, one run of earth wire of 2.5 sqmm copper;cable shall be measured & paid as one length).
Material and labour for for Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including GI earth strip 32x6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. If desired result not found , earthing will be re-done by the contactor without any extra cost.
Supply, laying, jointing & testing, XLPE insulated, armoured, heavy duty electric LT UG cable with multi stranded aluminium conductor, 1100 volts grade laid in trenches or in duct/passed through pipes or fixed to wall/poles etc cross sectional area of sizes 120 sqmm 3.5core complete all as specified and directed.
Supply and fixing XLPE insulated heavy duty electric cable of size 6 Sq mm 4 core with aluminium multi stranded conductor 1100 volts grade served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall sheaths laying in trenches/cable ducts, fixed to wall/pole complete all as specified
M& L for Spreading ribbed soil in trenches as in cable cushioning all as per IS 1255-1983 and as directed. Note :- Excavated approved soil shall be ribbed by using sieve to separate composite particles etc as per IS and refiiling in trenches before laying of cable 8 CM and 15 CM after laying of cable. This is than gently punned down to a depth of 10 cm above the top of upper most cable (ii) For the purpose of measurement only punned thickness only will be considered for payment.
Material and labour for Boring of holes under road, pavement, hard standing by adopting horizontal Boring including supply and inserting of HDPE pipe of 80 mm dia not less than 6kg/cm working pressure confirming to IS all as specified and directed. Note: Depth will not be less than 1.00 M below the road pavement and hard standing Boring shall be carried out without damaging the road and hard standing.
Supply and fix of LED street light fittings 35 watts pressure die cast aluminium housing with toughened glass and high power LEDs with option of secondary optic with IP-66 ingress protection with 4/5KV external surge protection device, Manufacturers logo embossed on the housing for traceability (stickering/ printing not acceptable), system level efficacy of the luminarie is 110lm/W at L70. The color temparature is arround 5700/6500K with a color rendering index of 70. The luminaire if IP:66 protected with impact rasistence IK05 impact resistance, electronic driver complaint to IEC safety standards with power factor is greater than 0.9, voltage variation range 120-270V, THD less than 20%, high and LED with individual peanut lens and lena plate for better optics. The product should be tested for IEC60598 safety standards, LM80 report for LED, entire product including taking down the old u/s one complete all as specified and directed.
Supply and fix of LED flood light fittings 70 watts pressure die cast aluminium housing with toughened glass and high power LEDs with option of secondary optic with IP-66 ingress protection with 10KV external surge protection device, Manufacturers logo embossed on the housing for traceability (stickering/ printing not acceptable), system level efficacy of the luminarie is 110lm/W at L70. The color temparature is arround 5700K/6500K with a color rendering index of 70. The luminaire if IP:66 protected with impact rasistence IK08 impact resistance, electronic driver complaint to IEC safety standards with power factor is greater than 0.9, voltage variation range 120-270V, THD less than 20%, high and LED with individual peanut lens and lena plate for better optics. The product should be tested for IEC60598 safety standards, LM80 report for LED, entire product including taking down the old u/s one complete all as specified and directed.
Supply and fix GI tubing light grade of size 40 mm dia fixed to pole as protection pipe and street light brackets including GI fitings complete all as speified and directed.
Supply and fix flat mild steel confiriming to Fe 410 - W (Gde-E 250) clamps for street light brackets complete including required Nut bolts with washers any type any sizes for fixing of fo clamps and brackets.
Material and labour for Rigid non-metallic PVC conduit 20 mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. to be fixed on pole with all fittings including mouth pieces for passing of sub main wiring three core of copper wire 2.5 sqmm to provide woth conduit and connection to LED light and control box complete.
Supply & Erecting Mild steel tubular swaged pole 8.5 meter long 410, SP-22 and conform to IS 2713 (Parts 1 to 3) 1980 specification with cast iron base plate ,finial taper plug, bolts, nuts & screws as specified and the poles shall be coated with two coasts of black bituminous paint throughout internally and externally up to the planting depth painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of primer complete all as specified and as directed.Note (i) Excavation, earth work and PCC work for embedding pole shall be measured and paid seperately. (ii) Pole upto 1.5 m top of copping shall be painted with 2 coats of block and white strips alternate 30cm each over one coat of red oxide primer and marking pole numbers by using one coat of synthetic enamel white paint complete (iii) Steel tubular pole above 1.5 m shall be painted with 2 coats of alu paint over a coat of red oxide primer. The rate for above items shall be deemed to be inclusive in the quoted rate.
Material and labour for PCC 1:3:6 type C1 using 20 mm graded stone aggregate for stay and coping for poles including necessary form work to exposed surfaces finished smooth and even all as specified and as directed.
Supplying & fixing of terminal panel box of size 205 x 255 x 112mm of outdoor pole mounted front operated cubical type Box as per IEC 60439-1 (IS:8623) & IEC 60439 -2 dead back, free standing, dust and vermin proof, switchboard with IP 66 protection with suitable for use 440 volts, 3 phase 4 wire 50 Hz system. The Board/Panel shall be made out of moduler POLYCARBONATE THERMOPLASTIC ENCLOSURES. The gasket material shall be Polyurethane; while the gasket shall be internally embedded. The manufacturer of board/panel shall submit a copy of test report in accordance with IEC60529. The Panel Should be assembled at manufactures factory and Panel box having 6 Amp MCB (Make -Indo Asian/Havells/Legrand), 25 Sq.mm Terminal Block (04 Nos) , 6 Sq.mm Disconnected Terminal (01 No), 4 Sq.mm Earth Terminal (01 No) including MS clamp in suitable size with nut bolts Complete all as directed.
Material and labour in repairs Cable PVC insulated PVC unsheathed un-armoured copper conductor (multi stranded) of cross sectional area 1.5 sq mm 3 core drawing in PVC conduit/Steel tubular pole all as required for connections to light fittings complete all as directed.
M/S SRI BALAJI ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .