| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H3₹46.3 L−₹2.3 L (4.80%)Accepted-AOC 19 1A BOSE PUKAR ROAD KASBA GROUND FLOOR KOLKATA 700042 | KOLKATA | KOLKATA | WEST BENGAL | 700042 | H3 | Accepted-AOC Contract awarded to M/s Intime Commotrade Pvt Ltd | |
| 2 | H1₹48.7 LRejected-Finance 26M NEEM SARAI DHOOMANGANJ PRAYAGRAJ 211011 | PRAYAGRAJ | UTTAR PRADESH | 211011 | H1 | Rejected-Finance HIGHER RATES QUOTED THAN LI | |
| 3 | H2₹47.8 L−₹93,826.26 (1.93%)Rejected-Finance 2A 40 1 DHARMATALA ROAD KASBA KOLKATA WEST BENGAL 700042 | KOLKATA | KOLKATA | WEST BENGAL | 700042 | H2 | Rejected-Finance HIGHER RATES QUOTED THAN LI |
| Sl No | Description | Qty | Unit | Intime Commotrade Pvt Ltd H3 | SPS TRADING H2 | BHARAT CONSTRUCTION H1 |
|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. | 1.05 | Cum | 487 ₹511.35 Lowest | 502 ₹527.1 | 511 ₹536.55 |
| 2.00 | Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. | 32.72 | Sqm | 22 ₹719.84 Lowest | 23 ₹752.56 | 23 ₹752.56 |
| 3.00 | Dismanting of wrought iron or mild steel work af any description not otherwise provided for complete all as specified and as directed by Engineer-in-charge. | 1.2 | Qtl | 598 ₹717.6 Lowest | 616 ₹739.2 | 628 ₹753.6 |
| 4.00 | Dismantling Wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed. | 100 | Sqm | 12 ₹1,200 Lowest | 12 ₹1,200 Lowest | 13 ₹1,300 |
| 5.00 | Taking down cement plaster on brick or stone wall etc. including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed. | 10 | Sqm | 29 ₹290 Lowest | 30 ₹300 | 30 ₹300 |
| 6.00 | Taking down chowkat or frames exc 1.5 sqm but n exc 4.0 sqm each with shutter (without taking off shutters from the frame) complete all as specified and as directed. | 25 | Each | 122 ₹3,050 Lowest | 126 ₹3,150 | 128 ₹3,200 |
| 7.00 | Taking down Chowkats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and as directed. | 10 | Each | 134 ₹1,340 Lowest | 138 ₹1,380 | 141 ₹1,410 |
| 8.00 | Surface excavation n.exc 30 cm deep and and avg 15 cm deep and getting out soft and loose soil complete all as specified and directed. | 25 | Sqm | 32 ₹800 Lowest | 33 ₹825 | 34 ₹850 |
| 9.00 | Excavation in post holes not exc 0.50 cum, getting out, and removing surplus soil not exc 50 m in soft/loose soil all as specified and directed. | 20 | Each | 255 ₹5,100 Lowest | 263 ₹5,260 | 268 ₹5,360 |
| 10.00 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil
Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. | 40 | Cum | 300 ₹12,000 Lowest | 309 ₹12,360 | 315 ₹12,600 |
Tender Value
₹47.9 L
EMD Value
₹95,700
Closing Date
1 Sept 2025, 6:00 pmClosed
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DISTT- BURDWAN, STATE-WEST BENGAL PIN-713420
All s per BOQ
2025_MES_720005_2
8500-372/E8
Open Tender
Civil Works
Works
180 days
PANAGARH
As per tender documenes
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹95,700
Yes
24 Sept 2025
9 Aug 2025
2 Sept 2025
9 Aug 2025
1 Sept 2025
18 Aug 2025
Amount
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismanting of wrought iron or mild steel work af any description not otherwise provided for complete all as specified and as directed by Engineer-in-charge.
Dismantling Wall & ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
Taking down cement plaster on brick or stone wall etc. including racking out joints hacking for key scrubbing down with water etc complete all as specified and as directed.
Taking down chowkat or frames exc 1.5 sqm but n exc 4.0 sqm each with shutter (without taking off shutters from the frame) complete all as specified and as directed.
Taking down Chowkats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) complete all as specified and as directed.
Surface excavation n.exc 30 cm deep and and avg 15 cm deep and getting out soft and loose soil complete all as specified and directed.
Excavation in post holes not exc 0.50 cum, getting out, and removing surplus soil not exc 50 m in soft/loose soil all as specified and directed.
Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding.
Excavating over areas, n exc 1.5 m deep and getting out and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, wateri complete all as specified and directed.ng and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed.
M&L for 200/300 mm thick (compacted) in three layers of each 100mm thick in pavings, with mix of fly ash, clinker & stone dust in the proportion of 1:3:6 (ie 10% fly ash, 30% clinker and 60% stone dust ) laying in layers n. exc 10cm thick, watering, ramming and compacted with hand/power roller 8 to 12 tonn roller to required camber and gradient complete all as directed by Engineer-in-Charge.
M&L for broken stone hardcore of guage n. exc 63mm, deposited, spread and levelled in layers n. exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for Loose filling with aggregates of gauge 40 to 80 mm in soakage pits, soakage wells complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate, in foundations, filling and mass concrete complete all as spcified.
M & L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) as foundation and mass filling complete all as specified and directed.
M&L for M-25 Design mix using 20mm stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concret complete all as specified and directed.
M&L for providing reinforcement cement concrete M-25 (Design Mix) as in columns complete all as specified and directed.
M&L for providing reinforcement cement concrete M-25 (Design Mix) as in Beams, cantilevers, ressummers, lintels over 1.5m span concrete complete all as specified and directed.
M&L for providing reinforcement cement concrete M-25 (Design Mix) as in chajja complete all as specified and directed.
M&L for providing reinforcement cement concrete M-25 (Design Mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves complete all as specified and directed.
M&L for damp proof course 40mm thk in cement concrete 1:2:4 type B-0 to horizontal or vertical surfaces including necessary form work and applying evenly a coat of blown bitumen @ 1.50 kg clean dry sand @ 0.05 cum/ sqm complete all as specified and directed.
M&L PCC 1:3:6 type C2 40mm graded agregate as in surface channel and drain etc complete all as specified and directed.
M&L for forming fair finished drain or channel of manholes inner girth exceeding 30cm in cement concrete using extra cement including forms, mould mitered stopped ends etc all as specified complete all as specified and directed.
M&L for PCC 1:3:6 type C1 as in lintels / beam upto 1.5m clear span, and other similar bands, copings, kneelers, apex stones, bed plates, kerbs and haunching/ benching, water troughs and the like including weathering, slightly rounded or chamfered ang complete all as specified & directed
M&L for providing RCC precast cement concrete type B-1 (1:2:4) (using 20 mm graded stone aggregate) as in cover slab for manhole and similar article with plain face set in cement mortar (1:4) complete all as specified and directed
M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface of concrete complete all as specified and directed.
M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form) to sides of pillers, posts, struts, pier, columns and stanchions complete all as specified and directed.
M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides and fair finish soffits of floor or roof beam,beam hauchings, girders, bressum-mers, lintels cantilever, shelves including supports, overhangs, etc also splays between floors and beams etc complete all as specified and directed.
Formwork to chullah hoods, chajjas, troughs and similar fair finish items including edgges complete all as specified and directed.
M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; n.exc. 200mm thick (Horizontal or sloping) fair finished surfaces of concrete flat complete all as specified and directed.
M&L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
M & L for TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as in stirrups, spacers and binders complete all as specified and directed.
M&L framed work such as grills ,grating,etc,with ends of bars shouldered and or riveted or forged into spike ;framed guard bars for windows and iron gate conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed.
S&F for Rolled Mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment (Fe-410W Gde-E-250 Quality B), all as specified and as directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe-410- W(Gde- E-250) quality-B. complete all as specified and directed.
S&F for Rolled Mild steel Joist, channel, angle, or tee sections (Fe-410W Gde-E-250 Quality B) fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated), all as specified and as directed.
S&F for wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165, all as specified and as directed.
S&F for Mild steel screw bolts (machine made) with hexagonal or square heads (Diameter of neck 16 to 20mm) at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n. exc 10 cm long, all as specified and as directed.
S&F Chimney bars (straight or camber); bearing bars; ton-gues or water bars for window frames; window guard bars, plain let in & fixed independently in wooden frames L or T section support for shelves etc., & similar articles conforming to Fe 290-0 Gde E-165 complete all as specified and as directed.
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated of any profile steel sheet corresponding to IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in roof covering fixed with self tapping screws as specified up to anyheight including all necessary scaffolding and safety measures complete all as specified and directed
M & L for pre-painted hot-dip aluminium-zinc alloy metallic coated plain steel sheet as per IS 15965:2012 of durability class 3, atmospheric classification category 3, coating class AZ150, 0.50 mm thick, of an approved colour and having yield strength of 550 MPa as in ridge/ valley/ gutter fixed with self tapping screws as specified any height Mtr height including all necessary scaffolding and safety measures complete all as specified and directed
M&L for Brick work with fly ash bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 Complete all as specified and as directed.
M&L for Brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:4 with Old size bricks complete all as specified and directed.
M&L for grading roof in cement mortar 1:3, 25mm thick in edge and 50mm thick in ridge including necessary curing complete all as specified in SSR Part I clause No 11.42.2
M & L for providing water proofing treatment with a layer of APP based polymeric membrane, 3 mm thick (minimum), weighing not less than 3.60 kg/Sqm reinforced with polymer non woven fabric (weighing not less than 160 gm/ Sqm) shall be applied over one coat of cold bituminious primer @ 0.40 ltr/ Sqm ( membrane shall be laid using butane torch and sealing all joints etc, complete all as specified and directed .( Note: The overlaps shall be of minimum 75 mm on longitudinal direction and 100 mm on transverse direction) complete all as specified and directed.
S&F Solid PVC door frame of size 50mm x 95mm made out of 5mm wood grain printed PVC sheet reinforced with M.S. tube, in opening as per specification & drawing complete all as specified and as directed.
S&F Factory made solid moulded PVC door shutter 28 to 30mm thick (style) with 2,4 or 6 raised panel design with 2 mm thick 3D wood grain moulded PVC sheet polyurathane painted on the front face & 2 mm thick plain colour PVC sheet on back face with particle face supply & fixing on frame, as per specification & drawing complete all as specified and as directed.
M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50X100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp?ressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardan and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made complete all as specified and as directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative panelled decorative flush door shutter one side plain on other side of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) complete all as specified and as directed.
S&F factory made single extruded WPC (Wood Polymer Composite) wire gauzed i.e. panel shutter will be wire mesh in lieu WPC , the wire gauze shall be warped on additional square 8mm MS Solid tube and this tube shall be welded to MS frame complete all as specified and as directed.
S&F Powder coated aluminium (miimum thickness of powder coating 50 micron) work for doors, windows, ventilators frame and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per the directions of Engineer-in-Charge.
S&F Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-chargeher for openable/sliding shuttters) including all necessary fittings as directed.
Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement, all as specified and as directed.
S & F for 100 mm butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin,type B-21complete all as specified and as directed.
S&F extruded Aluminium alloy handles 150mm size, cast type, anodised complete all as specified and as directed.
S&F Aluminium, anodised, barrel tower bolts 200mm long of extruded section complete all as specified and as directed.
S & F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed
S&F Aluminium alloy, anodised, sliding door bolt 300mm long with hasp, staple (bolt type) & fixing clips of sheet, cast or extruded sections & fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and as directed.
S&F SS Double Handle of size 250mm long fixed in toughned glass door
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and as directed.
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples all as specified.
S&F Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed
S&F 4 mm thick sheet glass ordinary quality with oil putty in square n. exc. 0.5m in each pane complete all as specified and directed.
S&F Sheet glass 4.8 mm thick, ordinary quality & glazing with oil putty in square but n.exc 0.5 sq.m in each pane complete all as specified and as directed.
S&F Sheet glass 4.8 mm thick, ordinary quality & glazing with oil putty in square but exc 0.5 sq.m in each pane complete all as specified and as directed.
S&F 12mm thick Toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required, Handles, locking arrangement , rubber gasket/beading etc complete all as specified and directed.
S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and as directed.
M & L for rendering 15 mm thick cement plaster in cm 1:6 on fair faces brick or concrete surfaces of wall including finished fair and even all as specified and as directed.
M&L 15 mm thick rendering in cement mortar 1:4 inside and outside wall of manhole,drain,bldgs, of brick work/concrete suface finished fair and even with approved water proofing compound (as per manufacturing instraction), if ordered, complete all as specified and as directed. (Note:- WPC will be measured and paid separately)
Supply only integral Liquid water proofing compound.
Rendering 5 mm thick on fair faces of concrete surfaces, finished even and smooth on ceiling/chajja in cement mortar (1:3), complete all as specified complete all as specified and directed.
S&F anodised aluminium snap grid frame work for false ceiling, size of grid 605 x 605mm, including hangers 4 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means ceilings cleats made out od GI flat 40x3 mm size 60 mm long and expansion hold fastners 12.5 mm dia, and 4 mm thick non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium frame work, complete all as specifed and as directed.
M&L 100mm thick PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in sub base complete complete all as specified and directed.
M&L 50 mm thick PCC 1:2:4 type B2 using 40mm graded crushed stone aggregate as in receiving floor finishes complete all as specified and directed.
M&L cement concrete type B1 (1:2:4) using 20 mm graded aggregate 75 mm thick as in floor for receiving screed bed of floor tiling complete all as specified and directed.
M&L cement concrete type B1 (1:2:4) using 20 mm graded aggregate 40 mm thick as in floor complete all as specified and directed.
M&L for Vitrified Ceramic tiles 8-9 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15 mm thick cement mortar (1:6) screed etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. complete all as specified and directed.
Non Skid ceramic coloured tiles 7mm to 8mm thick, (square or rectangular) area of each tile exc 0.18 Sqm but n. exc 0.38 sqm in floors etc , over & including 15 mm thick cement mortar (1:6) screed etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 15 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete includung 20 mm screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for Machine cut Kota stone slab 15 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete 10 mm thick 1:4 screed bed cement mortar 1:6 complete all as specified and directed.
M&L for 19-18 mm thick Granite (of any type) work (table rubbed and polished)in steps, jambs, pillars, win?dow-cills, cooking plat?forms and like in cementmortar (1:4) including point?ing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, including screed bed of 20mm thick in 1:4 cement mortar, complete all as specified and as directed.
M&L green Marble work 16 to 18mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in CM(1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of Makrana Adanga complete all as specified and as directed.
M&L for 75 mm thick cement concrete M10 (Nominal Mix) with 40mm graded crushed aggregate finished even and fair laid to a slope of 1 in 12, laid in alternate bays, each bay not exceeding 3 m length with joint filled with bituminous mastic filling comprising a mixture of 1 part of heated Industrial bitumen 85/25 grade and two parts of heated sand complete all as specified
M&L for Machine pressed precast concrete interlocking pre-polished paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade, with grey cement and pigment, all as specified and as directed.
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including marking joints with or without grooves (thickness of joints except at sharp curve shall not more that 5mm), including making drainage opening wherever required complete as specified and as directed.
Three coats of white washing on new ceiling/chajja surfaces including preparation of complete all as specified.
Material and labour for two coat of cement based paint over a coat of alkali resistant primer, over new surfaces of wall complete all as specified and directed.
Material & Labour for preparation of new surfaces of plastered walls and applying Two coats of Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. over and including a coat of primer over plastered surfaces of walls to prepare the surface even and smooth complete all as specified.
Material and labour for treatment of wall & applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004 , alkali & fungal resistance, dirt resistance exterior paint of required shade (Company depot tinted) with silicon additives@ 1.43 litre/10sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified and directed.
M&L for two coats plastic emulsion paint on new plastered surfaces over a coat of alkali resistant primer over a coat of putty to bring the plastered surface uniform complete all as specified and directed
Two coats of synthetic enamel paint over & including a coat of red oxide primer over new steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified and directed.
S & F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall with clamps and jointed complete all as specified and as directed by EIC.
E/M PORTION M & L for concealed point wiring for fan/light point controlled by one one way switch complete with 1.5 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red/yellow/blue wires for phases and black wire for neutral),drawn into and including non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc. and including PVC FRLSH insulated 1.5 sq mm copper conductor for earth continuity (Green Colour) and connected to common earth dolly including sunken in GI terminal box 2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets ect. Note : a) Note :- Cost of PVC conduit, cutting chases of wal/ceilingl, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.
All as per item No. 97 here-in-before but 5 Amp socket on same board with other switches.
All as per item No 97 above but using 2.5 sqmm FRLSH PVC insulated unsheathed multi strand copper cable (1100 V) for line conductor and 2.5 Sqmm FRLSH PVC insulated unsheathed solid copper cable (1100 Volts) for earth continuty wire for one 15/16 amp multi socket out let on independent board.
Supply and fix switch piano flush type, single pole, 5/6 Amps, one way complete all as specified.
Supply and fix switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified. (Independent board)
S&F socket outlets 2 in 1, 5 pin, 5/6 Amps flush type 230/240 V complete all as specified and as directed .( For Same Board only)
Supply & fix ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
Supply and fixing lamp holder, PVC/polycarbomate type with back plate straight of angle suitable for LED lamp complete all as specified and directed.
Supply and fixing wall mounted fans complete with blades, in built regulator and accessories, 230 V, 400 mm sweep. Min air delivery 50 CFM, 90 degree oscillation and colour white complete all as specified and directed.
Supply and fixing for concealed type sub main wiring with two run of 4.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and including through Rigid non-metallic PVC conduit(medium) ISI marked of size 25mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxes etc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc. including one run of 4.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified. Note : (i) Note : 2 runs of line conductor, one run of earth continuity conductor, one run of PVC conduit shall be measured as unit length. (ii) Cost of PVC conduit, conductors, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate.
S&F in repairs LED 20 Watt tube light fitting intregated type, including LED retrofit tube lamp 20 W , LED tube light nominal power 20 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours and LED batten with aluminium housing and polycarbonate diffuser complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting complete all as specified & directed. . Note (i) Make of batten and LED tube lamp should be of same make.
S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, Ik09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing with all as specified and directed .
Supply and fixed MCB SPN 32 Amps, 'C' curve 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed.
Supply and fixed MCB SPN 40 to 63 Amps, 'C' curve 10kA, 240 Volts and to be housed in DBs complete including necessary connection all as specified and directed.
Supply and fixed MCB SP 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed.
Material and labour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mm mm buried directly in ground (Earth pit not less than 2.25m below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI wire 4 mm as earth lead by means of bolt, nuts, check nuts and washers of galvanised iron or steel, upto 7.5m length, earth strip protected by and including 15 mm dia GI pipe (light grade) and connected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC (1:3:6) type C1 , Precast RCC (1:2:4) Type B1 cover slab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100 mm C/C both ways with one handle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm bore GI Pipe (Medium Grade) for watering, Charcoal and salt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any type of soil and disposal of spoil to a distance n.exc 50 m and necessary testing complete all as shown in Electrical Plate No 3 of SSR Part-I. NOTE : 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI wire of 32x6mm including protection pipe, from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI strip and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate
Supply, Laying, testing and connecting XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with solid aluminium conductor 1100 volt grade of size 2 core 10 sqmm. , laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including Brass Compression Cable Gland, Terminal Lugs,clamps,nut & bolts etc all as specified
Materials and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to 18 cm thickness complete all as specified and as directed.(Compacted thickness shall be measured)
Supply and lay in trenches fly ash bricks, for cable protection all as specified and directed by the Engr-in-Charge.
S&F Pipes galvanized, 50 mm bore “light grade”, supplied and laid complete including necessary fittings such as tees, bends, elbows, sockets, reducers etc as per site requirement or specified.
S&F Galvanised Iron pipe 50mm Bore (dia) 'Light Grade' for protection of UG cable laid in floors/Road Crossong ,complete all as specified and directed by engr-in-charge.
M & L for Boring of horizontal hole under road, pavement, hardstanding by trenchless technology using ultra sound technique and necessary machine with and including GI Pipe light grade of dia 100 with all fittings, for passing of cable complete all as specified. Note : (i) One run of boring of horizontal hole and one run of GI Pipe light grade of dia 100 with all fittings will be measured as one unit length. (ii) All the precaution to be taken by the contractor before drilling the bore. The contractor has to take plan of existing cables any type and pipe line in existing area before drilling the bore. (iii) Any damage to existing cables any type and pipe line in the way of drilling the bore will be repaired and make good by the contractor. No extra cost will be paid on this account. (iv) Contractor has to get the survey of route, length and depth for boring before quoting the rate.
SPS TRADING (BID ID -3412742)
Intime Commotrade Pvt Ltd (BID ID -3412708)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .