Supplying and Replacement of Panels (with accessories) and Wiremesh at Swarn Jayanti Park in Rohini (Horti. Zone).
2026_DDA_926927_1
41/EE(E)/ELD-12/DDA/2026-27
Open Tender
Electrical Works
Percentage
60 days
Horticulture Division
as per tender notice
11 documents required · 11 mandatory
₹0
₹55,321
Yes
26 Sept 2026
19 Sept 2026
26 Sept 2026
19 Sept 2026
25 Sept 2026
19 Sept 2026
19 Sept 2026 - 25 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, Replacement (Dismantling the existing feeder pillar), testing and commissioning of floor mounted L.T. feeder pillar (main panel) cubical type double door of size 1100 mm(W) x1250mm(H) x 400(Depth) mm deep with general arrangement made out of 2mm thick M.S. CRCA sheet having hinged gasketted covers and screwed knobs with double locking arrangement and rain protection covers 100 mm, supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering, earth studs including supply and fixing of following accessories complete as required (as per drawing approved by Engineer-in-charge) .
(a) Incomer 400 Amps. 4 pole MCCB, 50 K Amp.--1No.
(b) Downcomer 250 Amp, 4 pole MCCB, 36 KA ---3 no.
(c) Danger notice plate -----1 No
(d) Lifting hook on the top of feeder pillar ---1Set.
(e) AI. Bus Bar 400 amp. 4 with sleeve and nut bolts ( size 50 mm x 6 mm )-----1 Set.
(f) Ammeter (0-100Amp) 96mm X 96mm square type ---1 No.
(g) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No.
(h) Phase Indicating Lamp Set with fuses ----1 Set | 1,12,806 | Each | 1 | ₹1,12,806 |
| 2 | Supplying, Replacement (Dismantling the existing feeder pillar), testing and commissioning of floor mounted L.T. feeder pillar (pump panel) cubical type double door of size 1000 mm x 900mm x 300 mm deep with general arrangement made out of 2mm thick M.S. CRCA sheet having hinged gasket covers and screwed knobs with double locking arrangement and rain protection covers (100 mm), supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering, earth studs including supply and fixing of following accessories complete as required(as per drawing approved by Engineer-in-charge) .
(a)100 Amp. 4 Pole MCCB, 30 KA ---- 1 no. (Incomer)
(b) 3 phase DOL submersible pump starter with relay range of 9 to 14 Amp. --- 1 Set.
(c) 63 Amp FP MCB , C- Curve ----1 no.
(d)Single phase preventor & dry run protection relay + VI meter---1 no.
(e) Lifting hook on the top of feeder pillar ---1Set.
(f) AI. Bus Bar 100 amp. 4 strip, 300 mm long with sleeve and nut bolts ( size 20 mm x 5 mm )-----1 Set.
(g) Ammeter (0-100Amp) 96mm X 96mm square type ---1 No.
(h) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No.
(i) Phase Indicating Lamp Set with fuses ----1 Set
(j) Danger notice plate -----1 No | 33,843 | Each | 2 | ₹67,686 |
| 3 | Supplying, Replacement, testing and commissioning of floor mounted LT feeder pillar cubical type double door of size 1000 mm x 900mm x 300 mm deep duly compartmentalized and with general arrangement made out of 2mm thick CRCA sheet having hinged gasket cover and screwed knobs with double locking arrangement and rain protection covers 100 mm and supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls,duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles,ferrules wherever required, painting, numbering including supply and fixing of following accessories complete etc. as required (as per drawing approved by Engineer-in-charge) .
(a) 200 Amps.36KA Four Pole MCCB ('C'-Series), ----1 No.
(b) 100 Amp 30 KA FPMCCB ( c- Series) ---- 2 no.
(c) 6A-32 A DP MCB ('C'-Series),10KA ------4 No.
(d) Analogue Timer switch for daily operation and toggle switch for auto/manual --1 No.
(d) 32 Amps. AC-3, 3 pole power contactor -----1 No.
(e) 30 Ampere 4 way neutral link/connector ------2 Nos.
(f) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No
(g) Ammeter (0-30 A) 96mm X 96mm square type----1 no.
(h) Phase Indicating Lamp Set with fuses ----1 Set
(i) Danger notice plate -----1 No
(j) AI. Bus Bar 200 amp. 4 strip, 300 mm long with sleeve and nut bolts ( size 30 mm x 5 mm ) -----1 Set.
(k) Lifting hook on the top of panel board and lighting arrangement inside the feeder pillar---- 1 No. | 52,784 | Each | 1 | ₹52,784 |
| 4 | Supplying, Replacement (Dismantling the existing feeder pillar), testing and commissioning of floor mounted L.T. feeder pillar (pump panel) cubical type double door of size 1000 mm x 900mm x 300 mm deep with general arrangement made out of 2mm thick M.S. CRCA sheet having hinged gasket covers and screwed knobs with double locking arrangement and rain protection covers (100 mm), supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering, earth studs including supply and fixing of following accessories complete as required(as per drawing approved by Engineer-in-charge) .
(a) 100 Amps. 4 pole MCCB, 30 K Amp.--1No.
(b) 1 phase submersible pump starter panel . --- 1 Set.
(c) 6A-32 A DP MCB ('C'-Series),10KA ------2 No..
(e) Lifting hook on the top of feeder pillar ---1Set.
(f) AI. Bus Bar 100 amp. 4 strip, 300 mm long with sleeve and nut bolts ( size 20 mm x 5 mm )-----1 Set.
(g) Ammeter (0-100Amp) 96mm X 96mm square type ---1 No.
(h) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No.
(i) Phase Indicating Lamp Set with fuses ----1 Set
(j) Danger notice plate -----1 No
k) 30 Ampere 4 way neutral link/connector ------1 Nos. | 29,117 | Each | 2 | ₹58,234 |
| 5 | Supplying, Replacement (Dismantling the existing feeder pillar), testing and commissioning of floor mounted L.T. feeder pillar (Light panel) cubical type double door of size 1100 mm x 1250mm x 400 mm deep with general arrangement made out of 2mm thick M.S. CRCA sheet having hinged gasket covers and screwed knobs with double locking arrangement and rain protection covers (100 mm), supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering, earth studs including supply and fixing of following accessories complete as required(as per drawing approved by Engineer-in-charge) .
(a) 400 Amps. 4 pole MCCB, 50 KA .--1No.
(b) 250 Amp. 4 pole MCCB , 36 KA.---- 1 no
(c) 32 Amps. AC-3, 3 pole power contactor -----1 No.
(d)Analogue Timer switch----1 no.
(e) 6A-32 A DP MCB ('C'-Series),10KA ------3 No..
(f) Lifting hook on the top of feeder pillar ---1Set.
(g) AI. Bus Bar 400 amp. 4 strip, with sleeve and nut bolts ( size 50 mm x 6 mm )-----1 Set.
(h) Ammeter (0-100Amp) 96mm X 96mm square type ---1 No.
(i) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No.
(j) Phase Indicating Lamp Set with fuses ----1 Set
(k) Danger notice plate -----1 No
l) 30 Ampere 4 way neutral link/connector ------2 Nos. | 86,554 | Each | 1 | ₹86,554 |
| 6 | Supplying, Replacement (Dismantling the existing feeder pillar), testing and commissioning of floor mounted L.T. feeder pillar (Light panel) cubical type double door of size 1100 mm x 1250mm x 400 mm deep with general arrangement made out of 2mm thick M.S. CRCA sheet having hinged gasket covers and screwed knobs with double locking arrangement and rain protection covers (100 mm), supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering, earth studs including supply and fixing of following accessories complete as required(as per drawing approved by Engineer-in-charge) .
(a) 250 Amps. 4 pole MCCB, 36 KA -- 1 no.
b) 200 amp. 4 pole MCCB , 36 KA ---- 1 no.
(c)Analogue Timer switch----1 no.
(d)32 Amps. AC-3, 3 pole power contactor -----1 No.
(e) 6A-32 A DP MCB ('C'-Series),10KA ------2 No..
(f) Lifting hook on the top of feeder pillar ---1Set.
(g) AI. Bus Bar 300 amp. 4 strip, with sleeve and nut bolts ( size 50 mm x 5 mm )-----1 Set.
(h) Ammeter (0-100Amp) 96mm X 96mm square type ---1 No.
(i) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No.
(j) Phase Indicating Lamp Set with fuses ----1 Set
(k) Danger notice plate -----1 No
l) 30 Ampere 4 way neutral link/connector ------2 Nos. | 67,990 | Each | 1 | ₹67,990 |
| 7 | Supplying, Replacement (Dismantling the existing feeder pillar), testing and commissioning of floor mounted L.T. feeder pillar (pump panel) cubical type double door of size 1000 mm x 900mm x 300 mm deep with general arrangement made out of 2mm thick M.S. CRCA sheet having hinged gasket covers and screwed knobs with double locking arrangement and rain protection covers (100 mm), supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering, earth studs including supply and fixing of following accessories complete as required(as per drawing approved by Engineer-in-charge) .
(a) 125 Amps. 4 pole MCCB, 36 KA Amp.--2 No.
(b) 3 phase DOL submersible pump starter with relay range of 9 to 14 Amp. --- 1 Set.
(c) 63 Amp MCB , C- Curve ----1 no.
(d)Single phase preventor & dry run protection relay + VI meter---1 no.
(e) Lifting hook on the top of feeder pillar ---1Set.
(f) AI. Bus Bar 200 amp. 4 strip, 300 mm long with sleeve and nut bolts ( size 30 mm x 5 mm )-----1 Set.
(g) Ammeter (0-100Amp) 96mm X 96mm square type ---1 No.
(h) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No.
(i) Phase Indicating Lamp Set with fuses ----1 Set
(j) Danger notice plate -----1 No | 34,260 | Each | 4 | ₹1,37,040 |
| 8 | Supplying, Replacement (Dismantling the existing feeder pillar), testing and commissioning of floor mounted L.T. feeder pillar (Light panel) cubical type double door of size 1000 mm x 900mm x 300 mm deep with general arrangement made out of 2mm thick M.S. CRCA sheet having hinged gasket covers and screwed knobs with double locking arrangement and rain protection covers (100 mm), supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering, earth studs including supply and fixing of following accessories complete as required(as per drawing approved by Engineer-in-charge) .
(a) 125 Amps. 4 pole MCCB, 36 KA Amp.--1 No.
(b) 100 Amps. 4 pole MCCB, 30 KA Amp ---1 no.
(c)Analogue Timer switch----1 no.
(d)32 Amps. AC-3, 3 pole power contactor -----1 No.
(e) 6A-32 A DP MCB ('C'-Series),10KA ------2 No..
(f) Lifting hook on the top of feeder pillar ---1Set.
(g) AI. Bus Bar 200 amp. 4 strip, 300 mm long with sleeve and nut bolts ( size 30 mm x 5 mm )-----1 Set.
(h) Ammeter (0-100Amp) 96mm X 96mm square type ---1 No.
(i) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No.
(j) Phase Indicating Lamp Set with fuses ----1 Set
(k) Danger notice plate -----1 No
l) 30 Ampere 4 way neutral link/connector ------2 Nos. | 39,881 | Each | 1 | ₹39,881 |
| 9 | Supplying, Replacement (Dismantling the existing feeder pillar), testing and commissioning of floor mounted L.T. feeder pillar (pump + light panel) cubical type double door of size 1000 mm x 900mm x 300 mm deep with general arrangement made out of 2mm thick M.S. CRCA sheet having hinged gasket covers and screwed knobs with double locking arrangement and rain protection covers (100 mm), supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering, earth studs including supply and fixing of following accessories complete as required(as per drawing approved by Engineer-in-charge).
(a) 125 Amps. 4 pole MCCB, 36 KA Amp.--1 No.
(b) 3 phase DOL submersible pump starter with relay range of 9 to 14 Amp. --- 1 Set.
(c) 63 Amp MCB , C- Curve ----1 no.
(d)Single phase preventor & dry run protection relay + VI meter---1 no.
(e) Lifting hook on the top of feeder pillar ---1Set.
(f) AI. Bus Bar 200 amp. 4 strip, 300 mm long with sleeve and nut bolts ( size 30 mm x 5 mm )-----1 Set.
(g) Ammeter (0-100Amp) 96mm X 96mm square type ---1 No.
(h) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No.
(i) Phase Indicating Lamp Set with fuses ----1 Set
(j) Danger notice plate -----1 No
k) 30 Ampere 4 way neutral link/connector ------2 Nos.
(l)Analogue Timer switch----1 no.
(m)32 Amps. AC-3, 3 pole power contactor -----1 No.
(n) 6A-32 A DP MCB ('C'-Series),10KA ------2 No. | 40,349 | Each | 3 | ₹1,21,047 |
| 10 | Supplying, Replacement (Dismantling the existing feeder pillar), testing and commissioning of floor mounted L.T. feeder pillar (Light panel) cubical type double door of size 1000 mm x 900mm x 300 mm deep with general arrangement made out of 2mm thick M.S. CRCA sheet having hinged gasket covers and screwed knobs with double locking arrangement and rain protection covers (100 mm), supported with MS angle iron legs and bottom frame of size 35mm x 35mm x 5mm x 1mtr. long grouted with 1:3:6 CC foundation and should be 0.7 mtr. above ground level. Legs should be covered with brick walls, duly 1:4 cement plaster, connections, inter connections with suitable size of FRLS PVC insulated copper conductor using thimbles, ferrules wherever required, painting, numbering, earth studs including supply and fixing of following accessories complete as required(as per drawing approved by Engineer-in-charge) .
(a) 125 Amps. 4 pole MCCB, 36 KA Amp.--1 No.
(e) Lifting hook on the top of feeder pillar ---1Set.
(f) AI. Bus Bar 200 amp. 4 strip, 300 mm long with sleeve and nut bolts ( size 30 mm x 5 mm )-----1 Set.
(g) Ammeter (0-100Amp) 96mm X 96mm square type ---1 No.
(h) Voltmeter (0-500 Volt) 96mm X 96mm square type with selector switch ---1 No.
(i) Phase Indicating Lamp Set with fuses ----1 Set
(j) Danger notice plate -----1 No
k) 30 Ampere 4 way neutral link/connector ------2 Nos.
(l)Analogue Timer switch----1 no.
(m)32 Amps. AC-3, 3 pole power contactor -----1 No.
(n) 6A-32 A DP MCB ('C'-Series),10KA ------2 No. | 32,945 | Each | 3 | ₹98,835 |
stage.html
html • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.71 MB
PressNoticeNIT41.pdf
Additional Documents • 1.70 MB
NIT41.pdf
Tender Documents • 1.92 MB
BOQ_974087.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .