Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC | L1 | Accepted-AOC Found lowest and reasonable | |
| 2 | L2₹33.9 L+₹22,751.20 (0.67%)Rejected-Finance 289 KASERU KHERA MAWANA ROAD MEERUT 250001 U P | MEERUT | UTTAR PRADESH | 250001 | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹35.9 L+₹2.1 L (6.37%)Rejected-Finance | L3 | Rejected-Finance In order but L3 | |
| 4 | L4₹36.9 L+₹3.2 L (9.41%)Rejected-Finance 164 197 NEWAJPUR DASAULI KURSI ROAD LUCKNOW UTTAR PRADESH 226026 | LUCKNOW | UTTAR PRADESH | 226026 | L4 | Rejected-Finance In order but L4 | |
| 5 | L5₹38.7 L+₹5.0 L (14.7%)Rejected-Finance RADHA NIKUNJ L 2 SOUTH CIVIL LINES ROORKEE HARIDWAR UTTARAKHAND 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L5 | Rejected-Finance In order but L5 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
7 Jun 2024, 6:00 pmClosed
GE (U) Meerut cantt
Roorkee road Meerut Cantt
REPAIR/MAINT/REPLACEMENT OF LT PANEL, LT SWITCHGEARS AND ALLIED WORKS IN BHAGAT LINE AREA UNDER AGE E/M ELECT SUPPLY AT GE(U) MEERUT CANTT
2024_MES_654564_1
8591/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE (U) Meerut cantt
₹90,000
Yes
26 Sept 2024
17 May 2024
14 Jun 2024
17 May 2024
7 Jun 2024
31 May 2024
Amount
Supply, installing, errecting, testing and commissioning, factory made and tested LT Panel board with all accessories. LT Panel board, OUT DOOR type,over all dimension not less than 1.0 m(L)x0.5 m (W)x 1.2m(H),platform mounted, suitable for 415 volts 3 phase 4 wire, 50 Hz AC supply system, having bus bar chamber with insulated Aluminum busbars installed on porcelain / SMC insulators and all interconnection between main busbars as well as outgoing feeders shall be carried out with TPN Aluminum busbar of rating not less then 1.5 times rated capacity of individual out going feeders. The panel shall be dust and vermin proof, IP 56 class protection and made of 3.15 mm CRCA MS sheet and 50x50x6mm thick angle iron frame work, bottom channel of size: 70x40x5 mm powder coated finish over one coat of red oxide primer outside and two coats of red oxide primer on inside, front / back opening type, and fixing 2 Nos.danger notice plate with letter, figures and conventional skull bones in signal red colour and fixed front & back door to LT panel etc with voltage and danger indicated in Hindi and English, with double door shutter and locking arrangement (including provn of 65mm Godrej (Freedom) stranded lock with 2 keys, internal wiring with PVC insulated, stranded copper conductor, FRLS cables, IS-694 marked of adequate size but not less than 1.5 Sqmm. The platform shall be such that it is of a height 30 cm above the nearest ground level. complete all as specified and directed including connections of all out going/in coming existing cables of size 25 to 400 sqmm by drawing /digging out cable from loops in trenches/ ducts out side the Bldg inclusive of necessary excavation and earth work as required and relaying the cables with retrieved bricks and providing new sand cushioning and crimping suitable size Alluminium lugs for terminal connections of cables, necessary PCC foundation with plastering to the Panel board, All out going feeders shall be connected by cable through suitable size gland plate / glands.& The various feeders shall be indicated by 50 mm size letters in synthetic enamel white paint including taking out unserviceable panel complete all as specified and as directed by Engr-in-Charge.
(I) Incoming :-
(i) Aluminum busbar, 4 Pole, 600 Amps
(ii) MCCB 4P, 400A, 36 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 01 Nos.
(iv ) Indicating Lamp LED type 240 V 50 HZ AC supply set of three colour (RYB)-01 set.
(II) Outgoing :-
(i) MCCB 4P, 200A, 36 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 02 Nos.
(ii) MCCB 4P, 125A, 25 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 02 Nos.
(iii) MCCB 4P, 63A, 16 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 01 Nos.
All as per Srl item No1 above, but with followings:-
(I) Incoming :-
(i) Aluminum busbar, 4 Pole, 400 Amps
(ii) MCCB 4P, 250A, 36 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 01 Nos.
(iv ) Indicating Lamp LED type 240 V 50 HZ AC supply (Make BCH/SIEMENS/L&T) set of three colour (RYB)-01 set.
(II) Outgoing :-
(i) MCCB 4P, 160A, 25 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 02 Nos.
(ii) MCCB 4P, 100A, 16 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 03 Nos.
All as per Srl item No 1 above, but with followings:-
(I) Incoming :-
(i) Aluminum busbar, 4 Pole, 400 Amps
(ii) MCCB 4P, 250A, 36 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 01 Nos.
(iv ) Indicating Lamp LED type 240 V 50 HZ AC supply (Make BCH/SIEMENS/L&T) set of three colour (RYB)-01 set.
(II) Outgoing :-
(i) MCCB 4P,125,25KA with thermal magnetic:O/L & S/C protection, ICS=100% ICU=01 Nos
(ii) MCCB 4P, 100A, 25 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 04 Nos.
(iii) MCCB 4P, 63A, 16 KA, with thermal magnetic: O/L & S/C protection , ICS= 100% ICU = 01 Nos.
Supplying, installing, commissioing and testing of LT switchgear panel board ( Kiosk) of size not less than 600mmx600mmx500mm, IP-55 (outdoor type) , 415 Volts, 50 Hz, AC supply, three phase and neutral ( 4 wire) , 400 Amps coloured horizontal tinned Aluminium bus bars , factory made out of 3.15mm thick MS sheet structure mounted on rigid mild steel angle iron frame of 50mmx50mmx6mm with 400mm long extended legs grouting in PCC 1:2:4 type B1 of size 150mmx150mmx250mm , duly epoxy powder coated internally and externally with approved shade, rubber gasketted, hinged front double door and back openable doors with proper locking arrangements for dust and vermin proof ,complete including adjustable thermal and fixed magnetic release MCCB 4 pole, 200 Amps, 415V,36 KA,50 hz -01 No (incoming),suitable size cable allay, lugs , glands and making connections/ wiring with suitable size SC PVC insulated copper conductor cable including taking out old u/s pane board (kiosk) complete all as specified & directed.
Supplying, installing, commissioing and testing of LT switchgear panel board ( Kiosk) of size not less than 600mmx600mmx500mm, IP-55 (outdoor type) , 415 Volts, 50 Hz, AC supply, three phase and neutral ( 4 wire) , 200 Amps coloured horizontal tinned Aluminium bus bars , factory made out of 3.15mm thick MS sheet structure mounted on rigid mild steel angle iron frame of 50mmx50mmx6mm with 400mm long extended legs grouting in PCC 1:2:4 type B1 of size 150mmx150mmx250mm , duly epoxy powder coated internally and externally with approved shade, rubber gasketted, hinged front double door and back openable doors with proper locking arrangements for dust and vermin proof ,complete including adjustable thermal and fixed magnetic release MCCB 4 pole, 100 Amps, 415V,36 KA,50 hz -01 No (incoming),suitable size cable allay, lugs , glands and making connections/ wiring with suitable size SC PVC insulated copper conductor cable including taking out old u/s pane board (kiosk) complete all as specified & directed.
Supply and Laying in replacement of XLPE UG cable PVC insulated,bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of size 185 Sqmm 3.5 core in trenches or fixed on wall/floor/ pole complete all as specified and directed.
Supply and Laying in replacement of XLPE UG cable PVC insulated,bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of size 120 Sqmm 3.5 core in trenches or fixed on wall/floor/ pole complete all as specified and directed.
Supply and Laying in replacement of XLPE UG cable PVC insulated,bedded armoured heavy duty electric cable 1100 volts grade with aluminium conductor of size 95 Sqmm 3.5 core in trenches or fixed on wall/floor/ pole complete all as specified and directed.
Supply and Laying in replacement of XLPE LT UG cable PVC insulated,bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 25 Sqmm 4 core in trenches or fixed on wall/floor/poles complete all as specified and directed.
Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth for laying of cable, errection of poles, stay and pipe line,and getting out including taking out old u/s bricks for cale protections complete all as specified and directed
All as per item srl No 10 but above depth exceeding 1.5 Mtr and getting out complete all as specified and directed.
Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick complete all as specified.
Removal of excavated soil to a distance n. exc 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified.
M&L for fly ash old size bricks , straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection complete all as specified & directed.
M & L for local sand coushioning with dry and clean over and under the cable for protection of cable , 80 mm sand laid before laying the cable 150 mm sand after laying the cable and filling the sand in cable duct of inside the sub station building complete all as specified and directed
M&L for earthing complete with galvanised steel earth plate electrode, 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 3.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvanised strip 25x4 mm size as earthing lead by means of bolts, nuts, check nuts and washers of GI up to test point, GI tubing 15 mm bore medium grade protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal, salt complete all as per SSR with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way including earth work in any type of soil , removal of surplus soil to a distance n.exc 50m and connecting , testing on completion all as shown on electric plate No 03 of SSR -2009 Part I including taking out old u/s earthing complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted).
Material and labour for GI tubing light grade 100 mm bore for passing through cables, laid in treanches, under the floor, along the wall or along the pole with necessary clamps, nuts, bolts and washers etc. and making good disturbed surface of wall, floor etc including taking out old u/s GI pipe complete all as specified and directed .
Material and labour for GI tubing light grade 50 mm bore for passing through cables, laid in treanches, under the floor, along the wall or along the pole with necessary clamps, nuts, bolts and washers etc. and making good disturbed surface of wall, floor etc including taking out old u/s GI pipe complete all as specified and directed .
M & L for drilling suitable dia horizontal bore holes for insertion / laying of 50/100 mm bore GI tubing of any description below/under road surface/floors etc with using mechanical or manual devices as required at site including making good disturbed surface to match with the existing streta after laying pipes complete all as specified and directed
Supplying, transporting, erecting and fixing in replacement of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long). Including taking down old u/s pole and compleate all as directed by engr-in-charge.
S&F in repair MCCB, 4 pole, 50 Hz, 200 Amps, 25kA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
S&F in repair MCCB, 4 pole, 50 Hz, 160 Amps, 16kA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
S&F in repair MCCB, 4 pole, 50 Hz, 400 Amps, 36KA, rupturing capacity thermal adjustable type duly connected with copper spreader links and proper size lugs, nuts, bolts and washers for proper connections, all as specified and directed.
M& L for PCC (1:3:6) type C2 using 40mm graded stone aggregated as in foundation, filling and mass concrete using necessary form work complete all as specified and directed by Engr-in-Charge.
M&L for PCC (1:4:8) type D2 using 40mm graded stone aggregated as in foundation, filling and mass concrete using necessary form work complete all as directed by Engr-in-Charge.
Shikha Enterprises (BID ID -3021438)
BHAGWAN DAS & Co (BID ID -3022113)
SIYA ASSOCIATES (BID ID -3020632)
EX SOLDIERS MECHANICAL WORKS (BID ID -3019245)
janta tradrers (BID ID -3017510)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .