Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC 00 BHUSAR FARM KE PASS K K PURI NANDANPURA JHANSI UTTAR PRADESH 284003 | JHANSI | UTTAR PRADESH | 284003 | ₹2.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹2.5 L+₹14,629.45 (6.22%)Rejected-Finance CHANDIGARH | CHANDIGARH | CHANDIGARH | 160001 | ₹2.5 L+₹14,629.45 (6.22%) | L2 | Rejected-Finance not L1 |
Tender Value
₹2.4 L
EMD Value
₹4,758
Closing Date
4 Jun 2026, 11:00 amClosed
Executive Engineer, Electrical Division, M.C., Chd
Executive Engineer, Electrical Division, M.C., Chd
E.I. WORK IN IMPROVEMENT OF SANITATION BOOTHS (2 NOS) FOR SAFAI KARAMCHARIES AT DIFFERENT LOCATIONS OF SSK UNDER MUNICIPAL CORPORATION, CHANDIGARH
2026_MCC_91214_6
41/E/MCC/2026
Open Tender
Electrical Works
Percentage
30 days
E.I. WORK IN IMPROVEMENT OF SANITATION BOOTHS (2 N
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹4,758
6 Aug 2026
27 May 2026
4 Jun 2026
27 May 2026
4 Jun 2026
27 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and laying of insulated 2 core x 16mm2 aluminium multi conductor twin core flat unarmoured cable to fixed on the suitable clamps and nuts /bolts etc make finolex/ lapp/ polycab/ havell's/Cirtina or its equivalent of ISI marked. The work shall be executed to the entire satisfaction of engineer-in-charge. | 220 | Mtrs. | 122 | ₹26,840 |
| 2 | Supply and laying of insulated 2 core x 10mm2 aluminium multi conductor twin core flat unarmoured cable to fixed on the suitable clamps and nuts /bolts etc make finolex/ lapp/ polycab/ havell's/Cirtina or its equivalent of ISI marked. The work shall be executed to the entire satisfaction of engineer-in-charge. | 155 | Mtrs. | 92 | ₹14,260 |
| 3 | Supply & Erection of 1x18 watt retrofit LED tube rod with batten Supply & Erection of 1x18 watt retrofit LED tube rod with batten made of aluminium housing with PC diffuser Lumen out put should be more than 100 lumens per watt (1800 LUM) with LM 79 report from NABL. The make of the fittings should beHavells/ Wipro/ Twinkle/ Surya/ Phillips/ Bajaj . The work shall be executed to the entire satisfaction of Engineer-in-Charge. | 8 | Nos. | 696 | ₹5,568 |
| 4 | P/F of LED luminarie of size 2'x2' of 30-36 watt (595x595 mm) surface type including driver with system Lumens 3600-4000 Im having efficacy of minimum 100 lm/W. THD <10%, PF > 0.95, Having coloured temperature 4000-6500 K recess type suitable to be fixed in Armstrong/ grid ceiling. The fitting should provides soft light and glare free symmetrical illumination and is to be fixed in the existing false ceiling frame of make Havells/ Wipro/ Twinkle/ Surya/ Phillips/ Bajaj alongwith connection, testing and commissioning erc. This job also includes all petty material required to be entire satisfaction of Engineer-in-charge. Warranty:- The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. | 4 | Nos. | 3,736 | ₹14,944 |
| 5 | Supplying and fixing brass batten/ angle holder including connection etc. as required. DSR 1.34 | 6 | Nos. | 112 | ₹672 |
| 6 | Supply and Installation of MS bracket for installation of flood light. The work shall be executed to the entire satisfaction of Engineer-in-charge. | 2 | Nos. | 918 | ₹1,836 |
| 7 | S/E of 32mm dia X1m Long GI Pipe (Medium Class) Bracket for mounting of LED Street Lighting/Fitting on wall including bending the pipe of suitable size to the required shape (90 to 105 deg), 2 Nos M.S. Clamps with Nut, Bolts and Washer. GI Coating/Painting the flat iron with primer and finish paint as per relevant tender specifications | 4 | Nos. | 711 | ₹2,844 |
| 8 | Supply & Erection of high power approx 18-20 Watt LED Street Light luminaries:
High-brightness White LEDs sources with high transmittance LENS on each LEDs, system lumen output of Minimum 1800 lumens, in Maximum 18 watt System Watt Consumption with 100 lms/Watt system luminous efficacy, 4000 K to 6000 K color temperature & 70 CRI value for ensuring good quality light output. Life of at least 50,000 hours at 70% lumen maintenance & LED driver efficiency >95% Power factor greater than 0.90, THD<15% & min 6KV surge protection with operating voltage range from 120-270 V for ensuring lifelong high performance of luminaire, having in built protection against short circuit mis wiring, over voltage protection, the fixture is made of LM-6 Pressure die-cast aluminum with engraved company name & have IK05 & IP66 Class I protection with NABL Accredited LM-79 & LM-80 Report. The fixture should be comprehensively warranted to be repaired or replaced for any defect within 5 years of installations. The luminary should not be over power derived. The fitting shall be mounted on the plate bracket on existing pole including making connection, testing & energizing complete in all respect to the entire satisfaction of Engineer-in-charge The luminary should be make Philips/ Crompton/ Havell's/ Surya/ Wipro/Legero/HQ Lamps. | 4 | Nos. | 873 | ₹3,492 |
| 9 | Supply & Erection of high power120 Watt LED Flood Light luminaries:
High-brightness White LEDs sources with high transmittance LENS on each LEDs with peanut lens with toughened glass, secondary lens optics, system lumen output of system luminous efficacy of ≥120 lm/W, 4000 K color temperature & CRI<70 value for ensuring good quality light output. Life of at least 50,000 hours & LED driver efficiency >95%, potted driver and driver should comply cispr-15 and EMI/EMC compliance, Power factor greater than 0.90, THD<15% & min 4KV internal surge protection and 10KV External surge protection with operating voltage range from 120-270 V for ensuring lifelong high performance of luminaire, having in built protection against short circuit, over voltage protection, the fixture is made of LM-6 Pressure die-cast aluminum with engraved company name & have IK05 & IP66 Class I protection with NABL Accredited LM-79 & LM-80 Report. The fixture should be comprehensively warranted to be repaired or replaced for any defect within 2 years of installations. The luminary should not be over power derived. The fitting shall be mounted on the plate bracket on existing pole including making connection, testing & energizing complete in all respect to the entire satisfaction of Engineer-in-charge. The LED Street Light Fixture shall be installed on 7.5/9 mtr long pole. The luminary should be make Philips/ Crompton/ Havells/ Surya/ Wipro/Bajaj.The detailed specification for supply of LED Street light luminaries is as under (with 05 years warranty). 1. Thermal Management system Good Thermal Management system Management of LED should be provided and LED must be Mounted on heat sink conductive Aluminum with suitable large area Surface by means of fins to disciple Heat to ambient air.
2. Applicable standard The fixture should confirm to Application BIS/IES standard/ IESNA LM 20 | 2 | Nos. | 2,288 | ₹4,576 |
| 10 | Providing & Fixing Cable Junction box of size 250x200x100mm complete in all respect. The job included fixing of Junction box on the wall with all petty material as required. The work shall be executed to the entire satisfaction of Engineer-in-Charge. Make: Sintex | 6 | Nos. | 839 | ₹5,034 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.77 MB
BOQ_113507.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .