Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical PLOT NO 78 NUNEDRESHI COLONY B BEMINA BYPASS SRINAGAR SRINAGAR JAMMU KASHMIR 190018 | SRINAGAR | JAMMU AND KASHMIR | 190018 | Accepted-Technical Accepted |
| 2 | Accepted-Technical | Accepted-Technical Accepted |
| 3 | Rejected-Technical 1ST BHAT MANZIL HABBA KADAL SRINAGAR SRINAGAR JAMMU KASHMIR 190001 | SRINAGAR | JAMMU AND KASHMIR | 190001 | Rejected-Technical Rejected |
| 4 | Rejected-Technical | Rejected-Technical Rejected |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
22 Jul 2026, 11:00 amClosed
Executive Engineer MHD SKIMS/JVC
SKIMS Soura
SITC of AC units of different capacities at various of SKIMS Soura
2026_PWDJK_313578_2
MHD/SKIMS/JVC/07 0F 2026-27 DATED.24.06.2026
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
365 days
SKIMS soura
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Executive Engineer MHD SKIMS/JVC
₹44,000
1 Aug 2026
25 Jun 2026
22 Jul 2026
25 Jun 2026
22 Jul 2026
25 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | SITC of high wall mounted hot and cold split type air conditioning units based on inverter technology each complete with indoor unit and outdoor unit comprising of compressor, condenser coil, fan & evaporator coil, blower, filter etc including providing and fixing of copper refrigerant piping(3 meter) of suitable size insulated with nitrile rubber of recommended thickness, interconnecting of copper conductor power cables 3 core 4 sqmm and communication cable (5 meter) between the indoor unit and outdoor unit through requisite rating single phase automatic voltage stabilizer (Copper wound with OEM test certificate for its rating), MCB of required capacity, plugs and sockets are also included in the job. The automatic voltage stabilizer should be designed for voltage digital display board having input 130-300 V, Output: - 220V ± 5% , 50 Hz. The job includes providing and fixing of flexible condensate PVC pipe of 3mtr length or as required at site and related accessories for mounting of outdoor unit. The job includes DLP for a period of Two (02) year from the date of commissioning of equipment. The job also includes pressure testing, vacuum testing and charging of refrigerant for rated performance of air conditioning machine. The machine should be suitable for operation in ambient -7 to 40°C | - | - | - | - |
| 2 | Rated Capacity/ 100% Load:
Cooling: 6 kW minimum
Heating: 6 kW minimum | 1 | job | - | - |
| 3 | Rated Capacity/ 100% Load:
Cooling: 7 kW Minimum
Heating: 7 kW minimum
. | 1 | job | - | - |
| 4 | Supply, Installation, testing and commissioning including vacuuming and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF/ACs system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastomeric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : | - | - | - | - |
| 5 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 1 | RMT | - | - |
| 6 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 1 | RMT | - | - |
| 7 | 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 1 | RMT | - | - |
| 8 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm | 1 | RMT | - | - |
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.33 MB
BOQ_1015122.xls
BOQ • 0.26 MB
extac.pdf
PDF • 0.29 MB
corracII.pdf
PDF • 0.15 MB
corrlecture.pdf
PDF • 0.28 MB
corrlecture.pdf
PDF • 0.28 MB
ExtensioneNIT07.pdf
PDF • 0.56 MB
extensions.pdf
PDF • 0.27 MB
corrigendum7.pdf
PDF • 0.50 MB
corrnit07.pdf
PDF • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .