Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.0 LAccepted-AOC 53 TOLLYGUNGE CIRCULAR ROAD KOLKATA 700 053 | KOLKATA | WEST BENGAL | 700053 | L1 | Accepted-AOC Being lowest bidder and reasonable | |
| 2 | L2₹49.9 L+₹12,936.25 (0.26%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹51.0 L+₹1.2 L (2.46%)Rejected-Finance 28 H TOLLYGUNGE CIRCULAR ROAD KOLKATA 700053 | KOLKATA | KOLKATA | WEST BENGAL | 700053 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹53.0 L+₹3.1 L (6.31%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹53.1 L+₹3.3 L (6.53%)Rejected-Finance 24B JYOTISH ROY ROAD KOLKATA 700053 | KOLKATA | WEST BENGAL | 700053 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
2 Mar 2023, 6:00 pmClosed
GE(FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
REPAIR/ MAINT OF CERTAIN E/M AND B/R OF STP AND INSTALLATIONS WITH ALLIED WORKS AT FORT WILLIAM UNDER GE (FW) KOLKATA
2023_MES_579931_1
8982/FW/E8
Open Tender
Civil Works
Item Rate
240 days
GE(FW) Kolkata
Ref tender documents
7 documents required · 7 mandatory
₹500
GE(FW) Kolkata
₹94,000
16 Mar 2023
9 Feb 2023
3 Mar 2023
9 Feb 2023
2 Mar 2023
23 Feb 2023
Amount
SCHEDULE 'A' PART-I (BUILDING WORKS) Demolition of Cement Concrete (un-reinforced) in Ground Floors and Pavings not exc. 150mm thickness (above or below Ground Level), complete all as specified and as directed.
Demolition of brick work built in cement mortar or cement lime mortar including all quoins, arches, pillars etc complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided for, complete all as specified and directed.
Demolition of cement concrete (reinforcement cut as required to facilitate demolition), roof, floor, (other than ground floor), beams, stair case, landing, chajjas and similar suspended works, complete all as specified and directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) removing tiles from site and rubbish off the premises complete all as specified and directed.
Demolition of stone slabs and tiles of any description or thickness in floors/vertical surfaces, etc laid, bedded and pointed in any mortar, etc complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster from brick or concrete surfaces of any description including racking out joints, hacking for key, scrubbing down with water etc complete all as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation or for shafts, wells cesspits, manholes etc., not exceeding 10 sqm on plan and getting out in soft/loose soils, complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material not exceeding 50 metre and deposited where directed at a level not exceeding 1.5 metre above the starting point in soil complete all as specified and directed.
M&L for brick work using old size fly-ash bricks straight or curved on plan exc 6 metre mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L Brick Work with fly-ash Bricks Half-Brick thick, Old Size, built in Cement Mortar 1:4, Straight or Curved on Plan to any Radius, complete all as specified and as directed.
M & L for 20 mm thick plastering in two layers, 10 mm each in cement mortar 1:4 with water proofing compound (as per manufacturer's specifications) on brick/stone walls or concrete surfaces finished even and fair ( upto any height) for external surfaces complete all as specified and directed. Note : Water Proofing compound shall be measured and paid separately as "Supply only".
M&L 15 mm thick rendering in cement mortar (1:6) to brick or concrete wall surfaces, finished even and smooth without using extra cement, all as specified and as directed.
M&L 15 mm thick rendering in cement mortar (1:4) to brick or concrete wall surfaces, finished even and smooth without using extra cement, all as specified and as directed.
M&L 5mm thick cement plaster in cement mortar 1:3 on concrete surfaces of ceilings without using extra cement finishing fair and even including necessary scaffolding complete all as a specified and as directed
Supply only liquid water proofing compound complete all as specified and directed.
M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi tred/stopped ends etc complete all as specified and directed.
Use and waste of Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc.
M&L for M-25 nominal mix RCC (1:1½:3), type A-1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams, columns in floors, roofs, landings, balcones, canopies, duck slabs, shelves and like etc., complete all as specified and as directed.
M & L for Providing precast reinforced cement concrete Type B1 1:2:4 (20mm graded aggregate) Set in position in cement mortar 1:4 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including necessary forms, moulds, etc complete all as specified and as directed. (NOTE: MS reinforcement shall be measured and paid separately)
M&L TMT Bars 10 mm dia and over, cut to length, bent to shape required including cranking, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M&L TMT Bars 6-8 mm dia and over, cut to length, bent to shape required including cranking, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, complete all as specified and as directed.
M&L Glazed Ceramic colored tiles of size 300mm x 450mm x 7mm thick in vertical surfaces, set and jointed in neat cement slurry, fixed over and including 10 mm thick screed bed in cement mortar 1:4 as backing layer and pointed in white or colured cement to match, complete all as specified and as directed.
M & L for heavy duty ceramic floor tiles of size 300 x 300 x10mm thick in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete including 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed. (MAKE : JOHNSON, Model : Endura or equivalent item in other makes listed in the tender)
S&F in repair cast iron work Gd FG-150 unmachined as in brackets, gratings, gully traps, manhole covers etc in articles not exceeding 5 Kg each complete all as specified and directed.
M&L for Mild steel framed works such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walkways, railings, framework of water tanks and similar works conforming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia or fixing with galvanised steel staples supplied and fixed complete to wood or steel members, weight n exc 4 Kg per Sqm, complete all as specified and directed.
M & L for plain cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregates as in foundation filling, fixing of post holes, support to flag pipe and mass concrete complete all as specified and directed.
M&L for 100mm thick PCC (1:2:4) type 'B-1' (using 20mm graded crushed stone aggregate) as in sub base floors, complete all as a specified and as directed
M&L for 40mm thick PCC (1:2:4) type 'B-1' (using 20mm graded crushed stone aggregate) as in sub base floors complete all as a specified and as directed
M&L for 25mm thick PCC (1:2:4) type 'B-0' (using 12.50mm graded crushed stone aggregate) as in floors finished even and fair, complete all as a specified and as directed
M&L for 75mm thick PCC (1:3:6) type 'C-2' (using 40mm graded crushed stone aggregate) as in floor, plinth protection etc, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L for pre-polished Chequred cement concrete tiles (coloured) of size 400mmx400mmx 25mm thick , set, jointed and pointed in neat cement slurry in floor and pointed with white/coloured cement & pigment to match the surface laid over and including 25mm thick screed bed in cement mortar 1:6 complete all as specified and directed .
M&L for machine cut kota stone slab flooring 20-25 mm thick over 15mm thick screed bed in cement mortar (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete all as specified and as directed.
M&L for laying and fixing Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10 mm thick cement screed in cement mortar 1:3 and jointed etc complete all as specified and directed.
Taking out precast interlocking paver block, any size, and keeping aside for re-use or removal from site complete all as specified and directed.
Supply and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. (NOTE: Cost of sand cushioning is deemed to be included in the quoted rates)
All as per item No.39 above, but Relaying of paver blocks (obtained from dismantling/taking out here in before) in patches, complete all as specified and directed.
M&L for PCC (1:3:6) type 'C-1' (using 20mm graded crushed stone aggregate) as in Surface channels, drains, etc., including necessary form work, complete all as specified and directed..
M&L for PCC (1:2:4) type 'B-1' (using 20mm graded crushed stone aggregate) as in floorings, benching to drains, coping etc., and the like edge slightly rounded or chamfered including necessary form work, complete all as specified and directed..
M&L for plain cement concrete (1:2:4) type B-1 using 20 mm graded aggregates in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones , bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork complete all as specified and directed.
M&L Precast cement concrete type B1 (1:2:4) using 20 mm graded aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling), corbels, brackets, etc.(of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in CM(1:4) with joints to match, complete all as specified and directed.
M&L for Rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Gde Fe-410-W (Gde-E 250) quality-B complete all as specified and directed.
Labour only for fixing of old serviceable steel sections (obtained from dismantling), including necessary cutting, welding etc., complete all as specified and directed.
S&F Steel window with side hung shutter including box type hinges with steel handle and steel peg stay, complete without glazing bars, dovetailed or welded, complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters, from the frames) not exceeding 1.50 Sqm each and removing off the site complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters, from the frames) exceeding 1.50 Sqm but not exceeding 4 Sqm each and removing off the site complete all as specified and directed.
Taking down shutters of any description exceeding 1.00 Sqm but not exceeding 2.00 Sqm each and removing off the site complete all as specified and directed.
S&F for 2nd class HW, plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, moulded or chamfered, put together with glue, pinned at joints, complete all as specified and directed.
S&F Factory made 35mm thick with 2nd class hard wood, rail and style factory made plain framed panelled shutter (two/one panel) with lock, rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail & style as per IS:1003(Part-I) kiln seasoned and chemically pressure treated, complete all as specified and directed.
S&F 30mm thick 2nd class hard wood glazed & skeleton shutters, open rebated and prepared to received glass, gauge etc.(without sash bars) edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass etc, size of members of shutters as specified in SSR Part-I section 8, clause 8.20(a), complete all as specified and directed.
S&F Factory made solid PVC door frame (chowkhat) of size 50mmx47mm made out of 5mm plain colour wood grain PVC sheet used instead of plain colour PVC sheet & edges will be painted to match with printed sheet reinforced with MS square tube, S&F in opening as per specification & drg as per manufacturer instructions, all as specified and directed.
S&F Factory made solid PVC door frame (chow khat) of size 100 mm x 45mm made out of 5mm plain colour PVC sheet, frame reinforced with MS square tube of size 40mm x 20mm of 19 gauge throughout the frame, fixed in opening as per specification & drg as per manufacturer instructions complete all as specified and directed.
M&L for Factory made solid PVC moulded door shutter, 28 to 30 m thick(stiles) with 2,4 or 6 raised panel design with 2 mm thick moulded PVC sheet on the front face & 2 mm plain colour PVC sheet on back face with particle board core complete all as specified and directed.
M&L mild steel work as in hold fast made out of flat iron any size including necessary welding or fixing nut and bolts, and similar articles, complete all as specified and directed.
Supply & fixing 100 mm stainless steel butt hinges (medium weight) complete all as specified and directed.
Supply & fixing 75 mm stainless steel butt hinges (medium weight) complete all as specified and directed.
Supply and fixing 150mm extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
Supply and fixing 125mm extruded aluminium alloy handles, fabricated type, anodised complete all as specified and as directed.
S&F 150mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 200mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 300mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy all as directed complete all as specified and directed.
S&F as in repairs 300mm aluminium, anodised sliding door bolt with hasp, staple(bolt type) and fixing clip of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy all as directed complete all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
All as per item No. 66 here-in-before, but fixed in repair.
Hacking out old broken glass (any thickness and size or quality) from wooden frames glazed with putty or fixed with beads complete all as specified and directed.
S&F 4mm thick ordinary quality plain sheet glass and glazing in square n.exc. 0.5 Sqm in each pane complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
Preparation of new plastered surfaces of ceilings and applying three coats of white wash, complete all as specified and directed.
M&L preparation of newly plastered surfaces of walls and applying two coats of cement base paint with brush over a coat of alkali resistant primer, complete all as specified and directed.
M&L preparation of old treated surfaces of walls and applying two coats of cement base paint with brush, complete all as specified and directed.
M&L for preparation of new surfaces of walls including cleaning, watering to make the surface clean and free from dust and applying two coats of acrylic distemper, finished with rollers over a coat of alkali resistant primer complete all as specified and directed.
M&L for applying Two coats of acrylic distemper, finished with rollers to old decorated surfaces of wall including preparation of surface (by brooming down or steel wire brushing, scrapping down smoke, soot, moulds, moss, efflorescent salts, trading oil and greasy spots) complete all as specified and directed.
All as per Item No.75 above, but on ceiling
M&L for preparing new surface of wood or wood based material of any description and in any position not otherwise described n.exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of wood primer complete all as directed.
M&L for preparing old decorated surface of wood or wood based material of any description and in any position not otherwise described n.exc 10cm width or girth and applying one coat of synthetic enamel paint complete all as directed.
M&L Preparing new Steel or Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint over a coat of Red Oxide/ Zinc Chrome Primer (first quality), complete all as specified and as directed.
M&L preparation of old steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (first quality), complete all as specified and directed.
M&L for preparation of old treated/painted surfaces of walls and soffit of chajja, roof slab etc., by cleaning, brooming, rubbing and scrapping as required using broom, emery paper, putty blade/scraper as applicable to make the surface free from loose paint, algae formation, dust etc including necessary safety & protective measures such as safety belt, headgear etc including filling cracks upto 5mm with and including suitable elastomeric crackfill paste and applying two coats of weather proof exterior emulsion paint over a coat of suitable exterior primer, complete all as specified and directed.
Removal of existing water proof treatment of any description from roof surface including cement plaster/screed bed carefully from the surfaces, roughening concrete surfaces and cleaning the roof surfaces by brushing, sweeping and scrubbing down with water and removal of debris complete all as specified and as directed.
M&L for brushing cement slurry @ 2.75 Kg/sqm over cleaned roof surface prior to application of concrete complete all as specified and directed.
M&L for Providing Cement Concrete, Type B-0, 1:2:4 (using 12.50 mm graded Stone aggregate), as in roof padding, finished even and fair complete all as directed by Engineer - in - charge .
M&L 15 mm thick screed bed in cement mortar 1:3 over roof mixed with water proofing compound as per manufacturer's instruction complete all as specified and directed. (NOTE: WPC will be measured and paid separately)
M&L for water proofing treatment on existing cleaned RCC roof with the following specifications and manufacturer's instruction complete all as specified and directed :- (i) Preparing and cleaning of fully dried surfaces as per IS 3067-1966. (ii) Applying bitumen primer conforming to IS:3384-1968 over the cleaned base @ 0.50 litre per sqm. (iii) Providing a layer of 3 mm thick APP modified pre-fabricated five layer, weight not less than 3.6 kg/sqm, black finished reinforced with non-woven polyster matt membrane with butane torch application. Overlap shall be minimum 100 mm on the transverse direction and 75 mm on longitudinal direction. (iv) Applying two coats of bitumen based UV reflective paint with aluminium finish @ 0.10 litre per sqm over APP membrane.
Dismantling of plain or corrugated steel sheeting any gauge or any thickness in roof covering including stacking serviceable materials of re-use and removing unserviceable materials complete all as specified and directed.
S&F 0.50 mm thick TCT (total coated thickness) pre-coloured galvalume sheets with minimum base metal thickness of 0.45 mm, single skin high rib/multi rib profile galvalume sheeting having 1000-1020 mm width and 28-30 mm high crest @ maximum 250-255 mm pitch (centre) with sheets manufactured out of 0.50 mm this TCT (total coated thickness) high tensile galvalume sheets having tensile strength 550 MPA with 18-20 micron top coat over 5 micron primer and 8-10 micron alkyld backer zinc aluminium alloy AZ-150, sheets having a dip metallic zinc (43.5%0 aluminium (55%) & silicon (1.5%) with total mass coating of 150 gms/sqm on both sides, having wide pans with minimum 3 small stiffening ribs for effective water shedding and special male/female ends with full return legs on laps for purlin support and fixed as per existing profile of roof complete all as specified and directed.
All as per item No.88 above, but 0.50 mm thick coloured plain galvalume sheet as in ridge/valley gutter of roof.
S&F 2.0 mm thick fibre glass reinforced translucent corrugated sheeting with two corrugation side lap fixed with 'L'- type or 'J'-type or cranked hook bolts, complete all as specified and directed.
Dismantling structural steel work of any description including doors, gates, railing etc but excluding framed trusses complete all as specified and directed.
S&F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing of Fe-410- W(Gde- E-250) quality- B, complete all as specified and directed.
Supply and laying 450 mm bore reinforced concrete pipe of Class NP-2, laid and jointed with jute & cement mortar 1:1, complete with collars all specified and as directed.
S&F in repair Steel rolling shutters (Thickness of laths 1.25mm), with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type etc complete all as spd and as directed.
Repair to Steel rolling shutters any thickness size and shape with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in same position as indicated, complete: push pull or manual type etc complete all and as directed.
Dismantling of posts or struts (wood, steel or RCC) any description in any sections including taking out embedded portion and making good disturbed ground post embedded in concrete, complete all as specified and directed.
Dismantling of old chain link wire mesh fencing including flat iron, ms round supporting bars, bracing bar etc complete all as specified and directed.
Excavation in post holes each not exc 0.5 Cum getting out returning filling in and removing earth or broken rubble mixed with earth around in layers not exc 25 cm watering and removing surplus soil to a distance not exc 50m and making good surface as in soft / loose soils, complete all as specified and directed.
Supply and fixing Rolled mild steel in joist, channel, angle, or tee section fixed independently, upto a height of 6 metre from each floor level (cut to ordinary length i.e. within 20mm of the length indicated) of FE-410- W(Gde-E-250) quality-B including using iron props and steel plates to existing RCC overhead members like beams, slabs etc., so as to ensure safety of existing structure and floor during repairing works complete all as specified and as directed.
Mild steel work as in flat iron fillets for securing wire mesh etc. including all necessary drilling ,bolting or riveting ,etc.and similar work conforming to Fe 290 Gde E-165 complete as specified & directed.
S&F MS 11-15 mm dia screw bolts (machine made) with hexagonal or square heads at one end and screwed the other each screwed end to be fitted with washers exc 5 cm but n exc 10 cm long complete all as specified and as directed.
S & F MS 10 mm dia round bar and fixed independently to angle iron for chain link fencing cut to length, bend to shape required, complete all as specified and as directed
S&F 4 mm dia PVC coated galvanised mild steel chain link fencing of mesh size 50 x 50 mm fixed with straining bolts including line wire any mesh size and type to any type of standards, rails, straining bolts etc. including provision of binding wire, complete all as specified and as directed. NOTE: MS post, MS round bars, flat iron, nuts & bolts shall be measured and paid separately.
S&F in repair 15mm bore galvanised steel tubing (medium grade) with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
S&F in repair 20mm bore galvanised steel tubing (medium grade) with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed.
SCHEDULE 'A' PART-III (EXTERNAL WATER SUPPLY WORKS) M&L Cleaning of 0.240 MLD RCC construction equalization tank of size 5.0m x 4.0m x 2.0m (Inner dimension) along with fine bar screen chamber, grit chamber and connected system by blocking the inlet / outlet flow from manholes, lifting the excess semi-solid sewage water out of the sump, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed, and depositing in collection pit duly spreading of bleaching powder inadequate quality over sludge and adjoining area including necessary earth work for excavation of pit and returning filling, complete all as directed by the Engineer-in Charge.
M&L Cleaning of 0.240 MLD RCC construction clarified water tank of 8.5m x 4.0m x 2.0m (inner dimension) and lifting the excess semi-solid sewage water out of the sump, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed, and depositing in collection pit duly spreading of bleaching powder inadequate quality over sludge and adjoining area including necessary earth work for excavation of pit and returning filling, complete all as directed by the Engineer-in Charge.
M&L Cleaning of 0..240 MLD RCC construction FMR (fludised media reactor) with tube setter / lamela setter tank ( MBBR and tertiary system) of size 10.5m x 3.2m x 3.0m (Inner dimension) and lifting the excess semi-solid sewage water out of the sump, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed, opening the blocked manholes etc before normalising flow of sewer complete all as directed by the Engineer-in Charge.
M&L Cleaning of 0.240 MLD RCC construction sludge Holding tank of size 3.0m x 2.0m x1.8m (Inner dimension) and lifting the excess semi-solid sewage water out of the sump, removing the entire deposited sludge, mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed, and depositing in collection pit duly spreading of bleaching powder inadequate quality over sludge and adjoining area including necessary earth work for excavation of pit and returning filling, complete all as directed by the Engineer-in Charge.
M&L Cleaning of 0.240 MLD RCC construction filter water storage tank of size 3.0m x 3.0m x1.5m (Inner dimension) and lifting the mod water from the tank, removing the entire deposited mud, silt etc, scrapping the internal wall / floor with wire brush (to remove deposited scales, mud etc from the walls / floors by using suitable tools and plants, manually from the bottom of the tank) , and removing the same at a distance n.exc 50m from site where directed and depositing in collection pit duly spreading of bleaching powder inadequate quality over sludge and adjoining area including necessary earth work for excavation of pit and returning filling, complete all as directed by the Engineer-in Charge.
S&F in repairs MCB, 'C' series, TPN, 63 Amps, breaking capacity 10KA complete all as specified and directed.
S&F in repairs MCB, 'C' series, TPN, 40 Amps, breaking capacity 10KA complete all as specified and directed.
S&F in repairs MCCB 4 pole, 415 volts, adjustable type, 200 Amps with breaking capacity 25 KA, front operated with extension rod fixing on existing LT panel board complete all as specified and directed. (Make- L&T, Cat No: CM90642OOPO / C&S, Cat No: CSE2M250ATM4P-* / LEGRAND, Cat No: 4202 18 / HAGER, Cat No: HHT201DR)
S&F in repair DOL motor starter, in sheet enclosure with suitable contactor & overload relay, 415 volts, 3 ph, 2 HP and relay ranging 2.5-4 Amp complete with complete all as specified and directed. Make - C&S, Cat No: BE1-D1735-308 or equivalent model in L&T / HAVELLS / BCH / INDO ASIAN / HPL)
S&F in repair DOL motor starter, in sheet enclosure with suitable contactor & overload relay, 415 volts, 3 ph, 3 HP and relay ranging 4.0-6.0 Amp complete with complete all as specified and directed. Make - C&S, Cat No: BE1-D1735-310 or equivalent model in L&T / HAVELLS / BCH / INDO ASIAN / HPL)
S&F in repair DOL motor starter, in sheet enclosure with suitable contactor & overload relay, 415 volts, 3 ph, 5 HP and relay ranging 5.5-8.0 Amp complete with complete all as specified and directed. Make - C&S, Cat No: BE1-D1735-312 or equivalent model in L&T / HAVELLS / BCH / INDO ASIAN / HPL)
S&F in repair FSAD Submersible pump starter with D range contractor & robusta (F range) LR1D OLR & electronic Star Delta timer stranded power rating for 3 Phase, 415 volts, 7.5 HP and relay ranging 5.5 - 8 Amps, complete with complete all as specified and directed. Make - C&S, Cat No: BE3-D1735-312 or equivalent model in L&T / HAVELLS / BCH / INDO ASIAN / HPL)
S&F in repair FSAD Submersible pump starter with D range contractor & robusta (F range) LR1D OLR & electronic Star Delta timer stranded power rating for 3 Phase, 415 volts, 10/12 HP and relay ranging 7.0 - 10 Amps, complete with complete all as specified and directed. Make - C&S, Cat No: BE3-D1735-314 or equivalent model in L&T / HAVELLS / BCH / INDO ASIAN / HPL)
S&F in repair FSAD Submersible pump starter with D range contractor & robusta (F range) LR1D OLR & electronic Star Delta timer stranded power rating for 3 Phase, 415 volts, 15 HP and relay ranging 9.0 - 14 Amps, complete with complete all as specified and directed. Make - C&S, Cat No: BE3-D1735-316X or equivalent model in L&T / HAVELLS / BCH / INDO ASIAN / HPL)
S&F in repair FSAD Submersible pump starter with D range contractor & robusta (F range) LR1D OLR & electronic Star Delta timer stranded power rating for 3 Phase, 415 volts, 22-25 HP and relay ranging 18.0 - 25 Amps, complete with complete all as specified and directed. Make - C&S, Cat No: BE3-D2535-322 or equivalent model in L&T / HAVELLS / BCH / INDO ASIAN / HPL)
S&F in repair FSAD Submersible pump starter with D range contractor & robusta (F range) LR1D OLR & electronic Star Delta timer stranded power rating for 3 Phase, 415 volts, 30 HP and relay ranging 18.0 - 25 Amps, complete with complete all as specified and directed. Make - C&S, Cat No: BE3-D3235-322 or equivalent model in L&T / HAVELLS / BCH / INDO ASIAN / HPL)
Disconnecting of electric connection, taking out horizontal centrifugal type nonclogging self priming pumps of capacity 5.0 HP from sewage treatment plant transporting to workshop rewinding of the motor with suitable gauge of super enamelled insulated copper wire, reassembling the motor, transporting upto site, re-installation and testing of the assembly as directed including replacement of DE/NDE bearings - 02 Nos complete as directed by the Engineer-in-Charge. (Make of pump: Kirloskar)
S&F in repair CI foot valve 80 mm dia, flanged type and suitable nuts, bolts & washers, complete all as specified and directed.
M&L Mild Steel Screw Bolts (machine made) 11mm to 15mm diameter of neck and length of bolt exc 5 Cm and not exc. 10 Cm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, complete all as specified and as directed.
M&L complete removal of old paint on panel boards of any description, over 10 cm width or girth, cleaning and preparation and applying through spray painting two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F mild steel chain of length 8 metre, made out of 10mm rod 50mm dia rings weight not less than 16 Kg/Each including taking up or down existing chain, complete all as specified and directed.
Supply & Fixing analog Ammeter 0-50 Amps 3 phase, AM50A, 415 volts, AC supply of size 96 mm x 96 mm, with current transformer of suitable ratio incl taking down existing meter & CT complete all as specified and directed by Engr-in-charge. (Make - C&S Ref No AM50A or equivalent item in other approved makes mentioned in tender)
Supply & Fix analog Voltmeter 0-500 Volts 3 phase, VM 500 415 volts, AC supply of size 96 mm x 96 mm, incl taking down existing meter complete all as specified and directed by Engr-in-charge. Make - C&S Ref No VM5000 or equivalent item in other approved makes mentioned in tender)
Supply and fix LED Indicating lamp RYB (Red, Yellow & blue set of three),415V, as in repairs, complete all as specified and as directed by Engr-in-charge Make C&S or equivalent.
S&F in repair current transformer of ratio 30/5 complete all as specified and as directed
S&F in repair single phase preventer auto reset relay, 40 volts unbalance complete all as specified and directed by Engr-In-Charge. (Make: Minilec Cat No VSP-3 or equivalent item in other approved makes mentioned in tender)
Supply and laying in repair electrical insulating mat of size 2.0 m X 1.0 m, 2.5 mm thick, made out of dielectric elastomer , natural or synthetic in nature, having elastic properties, suitable for working voltage 11 KV, proof voltage 22KV, breakdown voltage 45 KV, fire retardant, having self-extinguishing properly within 5 seconds of lighting, high elongation & tensile strength, no tear or breakage due to trolley movement & foot traffic, resistant to acids and alkalies, solvents or transformer oil, pastable type, water and moisture proof complete all as specified and directed.
S&F in repair Add on auxiliary contract block 2NO + 2NC incl necessary elect connections including taking down existing contact block complete all as specified and as directed. (Make : L&T, Cat No CS94114 or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / AE / HPL)
Disconnecting of electric connection, taking out centrifugal induction motor of 2 HP from base, transporting to workshop for rewinding of the motor with suitable gauge of super enamelled insulated copper wire, reassembling the motor, varnishing, transporting upto site, re-installation at site incl overhauling, greasing of pump and testing of the assembly as directed including replacement of DE/NDE bearings - 02 Nos, for the following capacities, complete as directed by the Engineer-in-Charge for the following size of motor:- ( Make of pump: Kirloskar)
2.00 HP Centrifugal induction motor
3 HP motor Centrifugal induction motor
5 HP motor Centrifugal induction motor
7.5 HP motor Centrifugal induction motor
M&L Complete removal of old paint on surfaces of motor pump set of various capacity and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer (using spray gun) including preparation of surfaces for any description/type with marking of SM/MES No of pump sets complete all as specified and as directed by the Engineer-in-Charge for the following capacities :-
Motor pump set of 2 HP capacity
Motor pump set of 3 HP capacity
Motor pump set of 5 HP capacity
Motor pump set of 7.5 HP capacity
S&F in repair SS impeller suitable for mono block pump sets of various capacities complete all as specified and as directed for the following :- (Make - MBH or as per sample/ site requirement)
SS Impeller for pump set of 2 HP capacity
SS Impeller for pump set of 3 HP capacity
SS Impeller for pump set of 5 HP capacity
S&F in repair SS impeller as existing design of the vertical / Horizontal submersible sewage pump sets of various capacity, non clog type complete all as specified and as directed by Engr- in- charge for the following :- (Make - MBH or as per sample/ site requirement)
Pump shaft SS type of pump set of 3 HP capacity
Pump shaft SS type of pump set of 5 HP capacity
Pump shaft SS type of pump set of 7.5 HP capacity
Pump shaft SS type of pump set of 10 HP capacity
S&F in repair mechanical lower and upper seals of sewage submersible pump sets of various capacities, non clog type and filling new cooling oil complete all as specified and as directed for the following:- (Make - MBH or as per sample/ site requirement)
Mechanical lower and upper seal for pump set of 2/3 HP capacity
Mechanical lower and upper seal for pump set of 5 HP capacity
Mechanical lower and upper seal for pump set of 7.5 HP capacity
Mechanical lower and upper seal for pump set of 10 HP capacity
Mechanical lower and upper seal for pump set of 22 HP capacity
Mechanical lower and upper seal for pump set of 30 HP capacity
Testing of inlet and outlet sewage samples as per Environmental Protection Act for effluent discharge into inlet surface water form Govt regconised or approved institute/test labs and submit the test report for the following parameters complete all as directed by Engr-in- Charge:- (i) pH valve (ii) TSS (iii) O&G (Oil & Grease) (iv) BOD (v) COD (vi) FC (vii) Nitrate (N) (viii) Residual Chlorine (Note : Testing of one sample each for inlet and outlet shall be considered as one job. Testing shall be carried out once in a month at regular interval)
S&F in repair Three pole power contactor of type MNX 25 suitable for 415 Volts, incl taking down complete all as specified and as directed. (Make : L&T, Cat No CS 94110 or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / AE / HPL)
S&F in repair Three pole power contactor of type MNX 12 suitable for 415 Volts, in cl taking down complete all as specified and as directed. (Make : L&T, Cat No CS 94108 or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / AE / HPL)
S&F in repair Three pole power contactor of type ML-1.5 suitable for 415 Volts, in cl taking down complete all as specified and as directed. (Make : L&T, Cat No SS 991851 or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / AE / HPL)
S&F in repair Three pole power contactor of type ML-2 suitable for 415 Volts, 40 Amps incl taking down complete all as specified and as directed. (Make : L&T, Cat No SS 90701 or equivalent model in HAVELLS / BCH / C&S / INDO ASIAN / AE / HPL)
Lifting & Lowering vertical non-clogging type submersible pump set of capacity 30 HP from sewage sump after disconnecting electric connection, cleaning, reassembling, re-installation, new refilling cooling oil as required and testing of the pump set including replacement of the following worn out parts complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Lifting & Lowering vertical non-clogging type submersible pump set of capacity 20 HP from sewage sump after disconnecting electric connection, cleaning, reassembling, re-installation, new refilling cooling oil as required and testing of the pump set including replacement of the following worn out parts complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Lifting & Lowering vertical non-clogging type submersible pump set of capacity 10 HP from sewage sump after disconnecting electric connection, cleaning, reassembling, re-installation, new refilling cooling oil as required and testing of the pump set including replacement of the following worn out parts complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Lifting & Lowering vertical non-clogging type submersible pump set of capacity 7.5 HP from sewage sump after disconnecting electric connection, cleaning, reassembling, re-installation, new refilling cooling oil as required and testing of the pump set including replacement of the following worn out parts complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Lifting & Lowering vertical non-clogging type submersible pump set of capacity 5.0 HP from sewage sump after disconnecting electric connection, cleaning, reassembling, re-installation, new refilling cooling oil as required and testing of the pump set including replacement of the following worn out parts complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Lifting & Lowering vertical non-clogging type submersible pump set of capacity 3.0 HP from sewage sump after disconnecting electric connection, cleaning, reassembling, re-installation, new refilling cooling oil as required and testing of the pump set including replacement of the following worn out parts complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Taking out vertical non-clogging type submersible pump set of capacity 30 HP from sewage sump with connected pipes after disconnecting electric connection, cleaning, washing the complete pump set, transporting to workshop for repair including dismantling of the pump set, rewinding of the motor with suitable gauge of super enamelled insulated copper wire, reassembling the pump set, refilling new cooling oil, transporting upto site, re-installation including and testing of the pump set including replacement of the following worn out parts and testing of pump set complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Taking out vertical non-clogging type submersible pump set of capacity 22 HP from sewage sump with connected pipes after disconnecting electric connection, cleaning, washing the complete pump set, transporting to workshop for repair including dismantling of the pump set, rewinding of the motor with suitable gauge of super enamelled insulated copper wire, reassembling the pump set, refilling new cooling oil, transporting upto site, re-installation including and testing of the pump set including replacement of the following worn out parts and testing of pump set complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Taking out vertical non-clogging type sub-mersible pump set of capacity 10 HP from sewage sump with connected pipes after disconnecting electric connection, cleaning, washing the complete pump set, transporting to workshop for repair including dismantling of the pump set, rewinding of the motor with suitable gauge of super enamelled insulated copper wire, reassembling the pump set, refilling new cooling oil, transporting upto site, re-installation including and testing of the pump set including replacement of the following worn out parts and testing of pump set complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Taking out vertical non-clogging type sub-mersible pump set of capacity 7.5 HP from sewage sump with connected pipes after disconnecting electric connection, cleaning, washing the complete pump set, transporting to workshop for repair including dismantling of the pump set, rewinding of the motor with suitable gauge of super enamelled insulated copper wire, reassembling the pump set, refilling new cooling oil, transporting upto site, re-installation including and testing of the pump set including replacement of the following worn out parts and testing of pump set complete as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Taking up electric driven vertical non clogging type submersible pump set of capacity 5.0 HP from sewage sump with connected pipes, transporting to workshop for repair including serving of pump set and motor, re-winding of the motor with suitable gauge of super enamelled copper wire, varnishing, drying, heating including greasing, oiling reassembling, transporting upto site, re-installation and testing of the pump set including replacement of following worn-out parts as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Taking up electric driven vertical non clogging type submersible pump set of capacity 3.0 HP from sewage sump with connected pipes, transporting to workshop for repair including serving of pump set and motor, re-winding of the motor with suitable gauge of super enamelled copper wire, varnishing, drying, heating including greasing, oiling reassembling, transporting upto site, re-installation and testing of the pump set including replacement of following worn-out parts as directed by the Engineer-in-Charge. (i) 'O' ring - 01 set (ii) Bearing - 02 Nos
Supply and fixed Mild steel plates chequared Fe-410-W (Gde-E-250) quality-B, 6mm thick as per site requirement as in repairs, complete all as specified and as directed by Engr-in-charge.
Taking up /down CI/DI water mains and connections/fittings of any type from trenches /walls/floors/(or any other location) for replacement /reuse in old/new location/diversion by burning out /removing of lead joints/tyton joints/rubber gasket joint complete all as specified and directed for the following size of pipes :-
80 mm bore
100 mm bore
150 mm bore
Note for Item No.158.00 Necessary earthwork, if any shall be measured and paid separately under relevant item.
Supply, laying and testing of ductile iron pipes with spigot and socket ends centrifugally cast of Class-7 in any length, laid in trenches complete all as specified and directed for following size of pipes :-
80 mm bore
100 mm bore
150 mm bore
S&F CI/DI bend upto 150 mm bore (any type, radius and angle) taper any type (straight, bend, increasing, decreasing or double socket etc) tee pieces, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs complete all as specified and as directed.
S&F CI butterfly valve, conforming to BS-5155, Gear operated with necessary rubber gaskets, nuts and bolts and washers of suitable size as in repair complete all as specified and directed for the following size of pipes :-
80mm bore
100mm bore
150mm bore
S&F Cast Iron Sluice valve of Class PN-1.6 long body type, heavy duty, ISI marked (IS 1538) flanged end with iron wheel and brass spindle including rubber gasket joints, nuts, bolts etc as in repair complete all as specified and directed for the following size of pipes :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
S&F in repair Cast Iron non-return valve, heavy duty, ISI marked (IS 5312) PN-1.6, flanged end including rubber gasket joints, nuts, bolts etc complete all as specified and directed for the following size of pipes :-
80 mm bore
100 mm bore
S&F in replacement of PVC insulated cable with Electrolytic Grade Annealed copper conductor 2.5 Sqmm, 3 core and multi-stranded flat for submersible pump motor, 1100 volt grade as per confirming to IS:694:1990 flat cable complete all as specified and as directed.
S&F in replacement of PVC insulated cable with Electrolytic Grade Annealed copper conductor 4.0 Sqmm, 3 core and multi-stranded flat for submersible pump motor, 1100 volt grade as per confirming to IS:694:1990 flat cable complete all as specified and as directed.
S&F in replacement of PVC insulated cable with Electrolytic Grade Annealed copper conductor 6.0 Sqmm, 3 core and multi-stranded flat for submersible pump motor, 1100 volt grade as per confirming to IS:694:1990 flat cable complete all as specified and as directed.
Burning out lead joints in position of cast iron pipes, fittings and re-making using old retrieved lead including earth work, if required, as in repairs, complete all as specified and directed for following size of pipes :-
80mm bore
100mm bore
150mm bore
200mm bore
Note for Item No 167.01 to 167.04 In case, inadequate lead is retrieved from burning out, for remaking joints, additional lead required shall be measured and paid separately as "Supply only".
Supply only lead confirming to IS 782 complete all as specified and as directed.
M&L Jointing of flanged pipes and fittings with rubber or fibre board gasket , bolts, nuts, washer including earth work, if required, as in repairs, complete all as specified and directed for the following size of pipes :-
80 mm bore
100 mm bore
150 mm bore
200 mm bore
M&L cleaning of underground sewage sump by blocking the inlet/outlet flow from manholes, lifting the excess semi -solid sewage water out of the sump, removing the entire deposited sludge, mud, silt etc, scraping the internal wall / floor with wire brush to remove deposited scales, mud etc from the walls / floor by using suitable tools and plants, manually from the bottom of the tank and removing the same at a distance n.exc 50m from site where directed and depositing in collection pit duly spreading of bleaching powder inadequate quantities over sludge and adjoining area including earth work for excavation of pit, returning filling, opening the blocked manholes etc before normalising flow of sewer, complete all as specified and as directed for the following capacities :-
60,000 gallons capacity underground sewage sump (Location: Calcutta Gate sewage Sump)
40,000 gallons capacity underground sewage sump. (Location: MAP Qtr sewage sump)
30,000 gallons capacity underground sewage sump. (Location: George Gate sewage sump)
20,000 gallons Capacity underground sewage sump. (Location: Strand Line-02 Nos, East gate , Treasury Gate, Water Gate & Golf Course sewage sump)
10,000 gallons capacity underground sewage sump. (Location: Chowringhee Gate sewage sump)
S&F in repairs GI "Medium grade" column pipe 100 mm dia, 3 mtr long with suitable size both end MS flange including rubber gasket, bolts, nuts and washers complete all as specified and as directed
S&F in repairs GI "Medium grade" column pipe 80 mm dia, 3 mtr long with suitable size both end MS flange including rubber gasket, bolts, nuts and washers complete all as specified and as directed
Supply and mixing Cultured Bacteriological solution for starting up of the system to treatment of sewage water complete all as specified and as directed. (Make- Bio-Clean, Micronz or equivalent make as approved by GE)
M&L for taking out air blower of capacity 7.5 HP from base for transporting to workshop for dismantling, overhauling and repairing of the air blower including re-assembling, greasing, transporting upto site, re-installation and testing of the assembly complete all as specified and directed by Engr-in-Charge including replacement of the following unserviceable parts :- (a) DE/NDE bearing - 02 Nos (b) Gear Oil - 01 litres (c) SS Shaft of suitable size - 01 No (d) Oil Seal - 02 Nos (e) Compressor Oil - 04 ltr
S&F in repair wet grinder belt A50 for Air Blower of capacity 7.5 HP complete all as specified and directed. (Make: Ecodrive Plus / Fenner or any other reputed make as approved by GE)
S&F in repair FRLS-H PVC insulated (unsheathed) single core multi strand cable with electrolytic grade annealed copper conductor suitable up to 1100 volts grade confirming to IS : 694, complete all as specified and as directed for the following sizes:-.
Single core 6.0 sqmm wire, FR-90
Single core 4.0 sqmm wire, FR-90
Single core 2.5 sqmm wire, FR-90
Single core 1.5 sqmm wire, FR-91
M&L for complete removal of old paint on surfaces of mono block motor pump sets and applying two coats of synthetic enamel paint over a coat of red oxide/zinc chloride primer (by using spray gun) and inscribe the SM/MES No of pump sets, complete all as specified and as directed by Engr- in- charge for the following :- (Make - MBH)
Mono block Pump of 2 HP capacity
Mono block Pump of 3 HP capacity
Mono block Pump of 5 HP capacity
Mono block Pump of 7 HP capacity
M&L for complete removal of old paint on surfaces of CI/DI pipe line and applying one coat of synthetic enamel paint including preparation of surfaces of any description/type, complete all as specified and as directed by Engr- in- charge for the following :- (Make - MBH)
CI/DI Pipe line 80mm Dia
CI/DI Pipe line 100mm Dia
CI/DI Pipe line 150mm Dia
CI/DI Pipe line 200mm Dia
CI/DI Pipe line 250mm Dia
S&F in repair Gun metal gate valve, 50 mm bore, as per IS : 778-84 Class-1 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions complete as all specified and as directed.
All as per Item No.180 above, but 40 mm bore
All as per Item No.180 above, but 25 mm bore
Rounaq Enterprise
CONSTRUCTION AND MAINTENANCE ENGINEERING CORPORATION
FAIRDEAL ENTERPRISE
SINHA ENTERPRISE
RAJ ENTERPRISE
MAZUMDER ENTERPRISE
MARUTI ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .