Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC | ₹24.9 L Quoted ₹25.3 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹26.0 L+₹70,572 (2.79%)Rejected-Finance | ₹26.0 L+₹70,572 (2.79%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹26.0 L+₹72,487 (2.86%)Rejected-Finance M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | ₹26.0 L+₹72,487 (2.86%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹28.4 L+₹3.1 L (12.1%)Rejected-Finance | ₹28.4 L+₹3.1 L (12.1%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹29.9 L+₹4.6 L (18.2%)Rejected-Finance | ₹29.9 L+₹4.6 L (18.2%) | L5 | Rejected-Finance Not being lowest |
Tender Value
₹29.8 L
EMD Value
₹59,500
Closing Date
1 Feb 2024, 6:00 pmClosed
GARRISON ENGINEER I R nd D WEST BANGALORE
GARRISON ENGINEER I R nd D WEST BANGALORE, DRDO, CV RAMAN NAGAR
REPAIR REPLACEMENT OF SECURITY STREET LIGHTS REPAIRING TO LT CABLES AND JOINTING BOXES AND ASSOCIATED MISC WORKS AT LRDE UNDER GE I R and D WEST BANGALORE
2023_MES_633247_1
GE(I)/R ND D/BAN/TOKEN/89 OF 2023-24 8243/E8
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER I R nd D WEST BANGALORE
CLASS AND CATEGORY AS PER NIT
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER I R nd D WEST BANGALORE
₹59,500
21 Dec 2024
3 Jan 2024
7 Feb 2024
4 Jan 2024
1 Feb 2024
19 Jan 2024
4 Jan 2024 - 18 Jan 2024
Amount
Excavation in trenches soft/loose soil not exc. 1.5 m wide not exc. 1.5 m in depth for taking out existing old / defective cables, laying of cables not exc. 10 Sqm on plan and getting out , trimming sides, forming bottom surface to required level complete all as specified and as directed Engineer-in-charge.
Returning filling including spreading, levelling , watering and well ramming in layers n.exc 25 cm in soil as directed by Engineer-in-charge.
Removing of excavated soil to a distance not exc 50 m & depositing where as directed at a level n.exc 1.5m above starting point all as specified and as directed by Engineer-in-charge.
Demolition and dismantling of old/damaged concrete of any description near existing transformers plinth/poles / Panels / sign boards foundation,coping etc of any type etc located at various locations carefully by arranging a proper supprt support to old poles / panels to avoid any damages etc, removing from site and making good distrubed portions near poles / panels etc to match with the adjacent areas in all respects per site conditions complete all as specified and directed by Engr-in-charge.
Cutting of bituminous road / floor for taking up existing cable / laying of new cable /relaying of U/G cables / GI Pipe / making good duct etc not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for refilling / with material and, watering well ramming / compacting and making good with PCC 1;3;6,type C-1complete all as specified and directed by Engineer-in-charge. Note : PCC 1:3:6 shall be measured and paid under the respective item of the work.
Material and labour for Plain cement concrete (1:4:8), type D2 ,using 40 mm graded stone aggregates for foundation of poles, transformer plinths, board foundations etc complete all as specified and directed by Engineer-in-charge.
Materilal and labour Plain Cement Concrete (1:3:6), type C1, using 20 mm graded stone aggregates for coping of poles / plinth blocks of HT poles etc., including necessary form work and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
Supply riddled earth soil confiming to IS-1255, spreading in cable trenches for protection of cables complete all as specified and directed by Engineer-in-Charge.
Material and labour Sub-class 'B' well burnt bricks of old size 230 mm x 115 mm x 75 mm laid breadth wise along the length of cable laid in trenches for UG cable protection all as specified and as directed by Engineer-in-Charge.
Laying only bricks removed from existing trenches ,of any size ,laid as cable protection complete all as specified and directed by Engineer-in-Charge.
Supply and lay pipe galvanised iron tubing light grade of 50 mm dia in trenches / near panel /near floors / near walls / post top lantern pole etc using GI reducer or bend, other fittings etc all as per site requirement complete all as specified and directed by Engr-in-charge.
Supply and lay pipe galvanised iron tubing light grade of 80 mm dia in trenches / near panel /near panel etc using GI bend, other fittings etc all as per site requirement complete all as specified and directed by Engr-in-charge.
Taking out the existing old or burnt or defective LT Under Ground cables undermentioned sizes from panels/duct /trench/loop etc near the sub stations/poles etc including disconnecting cables both ends, tracing out the fault with the help of megger as per site requirements for following cables complete all as specified and directed by Engineer-in -charge. Note:i) Earth work as applicable shall be measured and paid separately under relevent items. ii) Retrived serviceable bricks from site shall be properly stacked a side and reused as protection to U/G cable here-in-after. For cables upto 25 sqmm 4 core
All as per the item No 13 here above but for 35 Sqmm 3.5 core to 95 sqmm 3.5 core.
Laying only the serviceble portion of cable of undermentioned sizes as per site requirements as obtained against items here-in-before and carrying out necessary connections in and including new lugs complete all as specified and directed by Engineer-in -charge. Note - i) Straight through Epoxy joint joint as applicable shall be measured and paid seprately under relevent item of schedule (2) Unserviceable portions cable quantity has been considered against schedule of credit. For cables upto 25 sqmm 4 core
All as per the item No 15 here above but for 35 Sqmm 3.5 core to 95 sqmm 3.5 core
Supply, lay, testing and commissioning of cable XLPE insulated armoured aluminium conductor LT cable 1100 volts grade in tenches / on walls /poles including suitable MS clamps for fixing, new aluminium lugs for connecting complete all as specified and as directed by Engineer-in-charge. Cable size 10 sqmm 4 core
All as per the item No 17 here above but cable size 16 sqmm 4 core
All as per the item No 17 here above but cable size 50 sq mm 3.5 core
All as per the item No 17 here above but cable size 70 sq mm 3.5 core
All as per the item No 17 here above but cable size 95 sq mm 3.5 core
Material and Labour straight through cable heat shrinkble epoxy type joint kit for 1.1 KV grade complete with jointing material (Epoxy Based) and accessories suitable for following sizes complete all as specified and directed by Engineer-in-charge. For cable size upto 50 Sqmm 3.5 core
All as per the item No 22 here above but for 70 Sqmm to 95 sqmm 3.5 core
Material and labour for writing letters size of letter upto 1.5 inches using synthetic enamel paint or suitable stickers outdoor type on existing LT Indoor panels / Outdoor feeder boxes located at various places based on present Incoming and Out going cable area connections duly checked by firm electricians on the ground etc in and including cleaning and preparing surfaces in all respect as per site requirement complete all as specified and as directed by Engr-in-charge.
All as per item No 24 here-in-above but size of letter above 2 inches
Material and Labour for finding UG cable fault / defect of any size from the positions accurately using cable fault locator including finding of cable route as applicable on the ground, transportation, testing, restoring of the supply in all respects and commissioning etc complete all as specified and as directed by Engineer-in-charge.Note - 1) Earth work from cable fault position to nearesst cable loop and cable joints as per site requirement shall be measured and paid separately under relevant item of the schedule.
Supply, fabricate, install, testing and commissioning for outdoor type LT Bus bar Chamber Box of size 600 x 600 x400 mm, fabricated from CPRI validitated certificate panel manufacturers with powder coated painting made out of 3 mm CRCA sheet steel front and rear opening facility with tower bolt locking , pad locks - 02 Nos,Provn of earthing points - 02 Nos and four side slanting cannopy on roof top and mild steel channels base frame of suitable siize and placed with suitable PCC pedestal of not less than 0.5 mtr height as per site requirements in and incl TPN Aluminium Bus bar of 400 Amps Capacity for looping and branch connection the bus bar chamber placed on insulators with suitable Neoprene rubber gasket to make it completely dust and vermin proof complete including taking out the existing old burnt / defective LT bus bars of any type from existing locations by disconnecting incoming and all outgoing cables of any size all as specified and directed by Engineer- in charge.Note:- The quoted rate deemed to be included for connections of Incoming and all outgoing U/G cable, terminating with suitable cable gland, aluminium lugs in and including excavation,returning,removing and PCC work as per site requirement complete all as directed by Engineer-in-charge.
Supply and fixing MCCB 415 V 3 pole 100 Amps 25 KA in and including additions/alternations in the panel existing MCCB compartment as applicable as per site reuirements, connecting of cables with replacement of cable lugs/connectors complete including taking down old existing MCCB of any type all as per specified and directed by Engineer-in-charge.
Supply and fixing MCCB 415 V 3 pole 63 Amps 16 KA in and including additions/alternations in the panel MCCB compartment as applicable as per site reuirements, connecting of cables with replacement of cable lugs/connectors complete including taking down old existing MCCB of any type all as per specified and directed by Engineer-in-charge.
Supply install testing and commissioning timer switch box out door type complete in and including 3 phase contactor MCB TPN of rating 63 A coonnector fuse etc using suitable rating cable connections, toggle switch for auto / mannual mode, connecting incoming and out going cables LT cables with required addition / alterations to panel comparatments as per site requirements including taking down old existing timer box all as directed by Engineer-in-charge.
Disconnecting the existing defective or burnt out cable ends from the loop in/out boxes by opening connections by loosening the nuts, bolts, washers etc carefully, supply and fixing aluminium lugs with cable glands of appropriate size suitable for 10 to 25 sq.mm, 4 / 3.5 core LT cable for connecting the cable ends including testing complete all as directed by Engineer-in-charge.
Supply and fixing FRP loop in loop out boxes of size not less than 250 mm x 200 mm x 105 mm out door type duly fitted on bottom of steel tubular poles with suitable size clamps, bolts, nuts and washers complete with 2 No 4 way connector 32 amps heavy duty, and clamps made out of suitable MS flat with MS nuts, bolts etc Make - SYNTEX / HENSEL / HPL/POLYCON including taking out the exisitng unserviceable FRP loop boxes complete alongwith electrical connections as required at site directed by Engineer-in-charge.
Supply & fixing FRP loop in loop out boxes of size not less than 350 mm x 250 mm x 150mm out door type duly fitted on bottom of steel tubular poles with suitable size clamps, bolts, nuts and washers complete with 2 Nos 4 way connectors 63 amps heavy duty, and 2 nos clamps made out of FI 20 x 5mm and MS nuts, bolts etc Make - SYNTEX / HENSEL / HPL/PO;YCON including taking out the exisitng unserviceable FRP loop boxes complete alongwith electrical connections as required at site directed by Engineer-in-charge.
Supply , Fixing and Testing Powder coated Outdoor street light control box of size not less than 300 x 200 x 80 mm CRCA 3 mm thick IP 55 fabricated by CPRI approved panel manufacturere's in and including suitable terminal TPN 10 KA SMC Connector ( Make - Electro Fibres / Powermat / Ramanuj for 3 Phase Cable Line IN & OUT) , MCB 6 SP Amps ( Make - Siemens / L & T / Schneider), canopy weather proof hinged doors, locking system and arrangements for fixing on PCC / Steel Poles with MS clamps of size not less than 25 x 5 mm nut bolts washers etc as per site requirement ncluding taking out the exisitng unserviceable FRP loop boxes alongwith electrical connections as required at site complete directed by Engineer-in-charge.
Supply & fix PVC insulated 1100 volts Aluminium conductor cable for working voltage upto and including 1100 volts of size 6 sqmm 2 core from loop in box to fitting including taking down unserviceable defective cable all as specified and as directed.
Supply & fix PVC insulated 1100 volts copper conductor cable for working voltage upto and including 1100 volts of size 1 sqmm 3 core round type from loop in box to fitting including taking down unserviceable defective cable all as specified and as directed.
S&F GI bracket made of GI pipe 40 mm dia light grade bend to shape not less than 1.2 mtr with 2 Nos of MS clamps fabricated out of MS Flats of size no tless than 25 x 5 mm with suitable size bolts, nuts for fixing street light fittings complete including taking down the existing rusted brackets directed by Engineer-in-charge.
S&F GI bracket made of GI pipe 25 mm dia light grade bend to shape not less than 1.2 mtr with 2 Nos of MS clamps fabricated out of MS Flats of size no tless than 25 x 5 mm with suitable size bolts, nuts for fixing securit/ street light fittings complete including taking down the existing rusted brackets directed by Engineer-in-charge.
Material and labour for Painting to existing LT poles of any type upto 9.0 mtr long including bracket & other accessories as per site requitrement after preparing / scraping the metal surface with emery sheet in all respect for making smooth surface and painted with one coat coat of aluminium paint including writing pole No / feeder No on poles as per site requirement complete all as specified and as directed by Engr-in-charge. Note -: The bottom of Pole 1.5 mtr height above coping / ground level shall be painted with blue paint or other any colour as decided by Engineer-in-charge in consultation with LRDE and aluminium paint strips alternatively at an interval of 30 cm including writing the pole with white colour over black colour circle base all as per site complete all as specified and directed by Engr-in-charge .
M & L for Preparing old painted surface of post top lantern of garden lights up to 4 metres long and painting with two coats of Aluminium paint including white washing the coping portion above ground level all as directed by Engineer-in-charge.
Cutting , trimming and pruning of trees / tree branches of any girth up to 1 sq mtrs all around the top of the existing LT street light poles, bottm of the existing LT street light poles in and including required T&P ladders, knifes and axes etc, cleaning the disturbed area and removing the trees/tree branches and debris from the site and depositing where directed by Engr-in-Charge.
Taking down existing old or defective Street light/security light/perimeter light fittings / Post top lantern of any description and type from street light pole and from wall of buildings of any height complete after disconnecting the electrical connections properly without disturbing other electrical connections of poles / building cables complete directed by Engineer-in-charge. NOTES :- (i) Replacement of screws, nuts, bolts and consumables shall deemed to be included in the quoted rate. (ii) All the retrieved items will be offered under Schedule of credit and the items not included in Schedule of credit will be returned to AGE (E/M) Store yard.
Supply and fixing outdoor type LED street light fitting 25 watts IP 66 toughened glass high power LEDs lumens not less than 110LPW 10 KV SPD including taking down carefully defective fitting of any type complete all as directed by Engineer-in-charge. Make : Crompton or techno-commercially equivalent model in philips/Havells/Osram/ Wipro/ Bajaj/GE as approved by GE.
Supply and fixing LED Outdoor street luminaires 45 Watt Housing made up of pressure die cast housing with toughened glass and high power LEDs with secondary optics with IP65 protection,System efficacy ≥ 110 Lm/w , operating voltage between 140 - 270 V, AC, 50 Hz, PF >= 0.95,THD<10%, CCT 5700K, CRI >= 70 and Driver Should be Potted type Constant Currnet LED Driver with 4KV Inbuilt Surge, Driver Efficiency >85%, Driver having High Voltage, Short Circuit Protection and Driver Should be with BIS Certified with R number including taking down carefully defective fitting of any type complete all as directed by Engineer-in-charge. Make : Crompton or techno-commercially equivalent model in philips/Havells/Osram/ Wipro/ Bajaj/GE as approved by GE.
Supply and fixing outdoor type LED street light fitting 70 watts IP 66 toughened glass high power LEDs lumens not less than 110LPW 10 KV SPD including taking down carefully defective fitting of any type complete all as directed by Engineer-in-charge. Make : Crompton or techno-commercially equivalent model in philips/Havells/Osram/ Wipro/ Bajaj/GE as approved by GE.
Supply and fixing outdoor type LED street light fitting 120 watts IP 66 toughened glass high power LEDs lumens not less than 110LPW 10 KV SPD including taking down carefully defective fitting of any type complete all as directed by Engineer-in-charge. Make : Crompton or techno-commercially equivalent model in philips/Havells/Osram/ Wipro/ Bajaj/GE as approved by GE.
Supply and fixing LED Outdoor flood light 70 W Housing made up of pressure die cast aluminum housing with toughened glass and high power LEDs and secondary lenses with IP66 protection and System efficacy ≥ 110Lm/w, operating voltage between 140 - 270 V, AC, 50 Hz,PF >= 0.95,THD<10%, CCT 5700K, CRI >= 70 and Driver Should be Potted type Constant Currnet LED Driver with 4KV Inbuilt Surge, Driver Efficiency >85%, Driver having High Voltage, Short Circuit Protection and Driver Should be with BIS Certified with R number and 10KV SPD within luminaire ncluding taking down carefully defective fitting of any type complete all as directed by Engineer-in-charge. Make : Crompton or techno equivalent in philips/Havells/Osram/ Wipro/Bajaj/GE as approved by GE.
Supply and fixing out door type flood light fitting 120 watts toughened glass comprising of energy saving , environmental friendly, long life, exclusive innovative die cast aluminium IP-66 10 KV SPD lumens not less than 110 LPW flood light, suitable for dark areas / high Mass lighting building display lighting including taking down carefully defective fitting of any type complete all as directed by Engineer-in-charge of Make : Crompton or techno equivalent in philips/Havells/ Osram/ Wipro/Bajaj/GE as approved by GE.
Supply and fixing out door type flood light fitting 150 watts toughened glass comprising of energy saving , environmental friendly, long life, exclusive innovative die cast aluminium IP-66 10 KV SPD lumens not less than 125 LPW flood light, suitable for dark areas / high Mass lighting building display lighting including taking down carefully defective fitting of any type complete all as directed by Engineer-in-charge of Make : Crompton or techno equivalent in philips/Havells/ Osram/ Wipro/Bajaj/GE as approved by GE.
Supply and fixing LED Outdoor Decorative Post top lantern fitting 40 watt for 360° indirect light with IP 65 protection. Resistant to impact and corrosion. Glare-free and better uniformity and System efficacy ≥ 100Lm/w , operating voltage between 140 - 270 V, AC, 50 Hz, PF >= 0.95,THD<10%, CCT 5700K, CRI >= 70 and Driver Should be Potted type Constant Currnet LED Driver with 4KV Inbuilt Surge, Driver Efficiency >85%, Driver having High Voltage, Short Circuit Protection and Driver Should be with BIS Certified with R number including taking down carefully defective fitting of any type complete all as directed by Engineer-in-charge.Make : Crompton or techno equivalent in philips/Havells/ Osram/ Wipro/Bajaj/GE as approved by GE.
Supply& fixing of LED Driver circuit suitable for 25 to 48 Watt LED security / street light fitting of any type, make, model in and including taking down defective fitting from existing pole, refixing on the same pole or on any pole in any subject work area location after testing complete all as directed by Engineer-in-Charge.
Supply& fixing of LED Driver circuit suitable for 70 to 150 watt LED street light / flood light fitting of any type, make, model in and including taking down defective fitting from existing pole, refixing on the same pole or on any pole in any subject work area location complete after testing all as directed by Engineer-in-Charge.
Material and labour for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mmx 6 mm thick burried directly in ground vertically (earth pit not less than 2.25m deep below ground level) with top edge of the earth plate not less than 1.5m deep below normal ground level connected to galvanised earth wire 4 mm dia, 7.5m length by means nuts, check nuts and washers of GI or steel connected to main switch board including protection pipe light grade 15 mm pipe GI, watering GI pipe medium grade 20 mm, arrangement with PCC chamber, funnel with wiremesh, RCC slab cover incl excavation in any strata and returning, filling, removal surplus soil, charcoal salt complete all as shown in electric plate No 3 of SSR Part I complete all as specified and as directed by Engineer-in-Charge.
Labour and Tools as required for lowering the high mast rack of any height from the existing positions of in any location carefully, Checking, servicing, repairs to high mast structures, checking all electrical connections, cables in and including as under mentioned works and lifying up carefully after rectification of defects/ maint nature work services :- (a) Labour for replacement of unserviceable parts or flood light fittings along with connected electrical cables etc,refitting the entire mast rack assembly (b) Servicing and lubrication works to canopy, guides (for smooth separate ways for ropes & cable. (c) Adjustment of winch assembly properly on mast, Servicing and lubrication to flexible steel wire ropes, junction boxes, Air termination rods, Door transition plate, pully system, 3 phase motor and gear system all as per site requirements as directed by Enginer-in-charge. etc. Note for sl No. 47 : 1) The quoted amount is inclusive for all type of repairs and spares as required on the sites for proper working of high mast system is inclusive in the quoted rate. However Flood light fittings shall be measured and paid under relevent item of the schedules. Note for sl No. 1 to 55 : 1) The quoted firm is responsible to arrange required ladders, tools and safety gum boots and gloves to tradesmen during currency of contract. 2) During currency of contract, the quoted firm is responsible depute their supervisor to report incharge JE E/M office @ 9 AM daily for collecting subject work street lights complaints / works etc for rectification with their tradesmen in various subject work areas during currency of contract period.
Sahara Engineers
RRK PROJECTS
Solar Electricals and Electronics
srinivasa construction company
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .