Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 CrAccepted-AOC | ₹5.9 Cr | L1 | Accepted-AOC REASONABLE LOWEST BIDDER |
| 2 | L2₹6.1 Cr+₹17.7 L (3.02%)Rejected-Finance | ₹6.1 Cr+₹17.7 L (3.02%) | L2 | Rejected-Finance BEING NOT L1 |
| 3 | L3₹6.1 Cr+₹21.0 L (3.58%)Rejected-Finance | ₹6.1 Cr+₹21.0 L (3.58%) | L3 | Rejected-Finance BEING NOT L1 |
| 4 | L4₹6.1 Cr+₹24.7 L (4.20%)Rejected-Finance FLAT NO 03 PANCHAVATI BUILDING ADARSH NAGAR CHICALIM GOA 403711 | SOUTH GOA | GOA | 403711 | ₹6.1 Cr+₹24.7 L (4.20%) | L4 | Rejected-Finance BEING NOT L1 |
| 5 | L5₹6.2 Cr+₹31.9 L (5.43%)Rejected-Finance 660 POLICE LINE AREA HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹6.2 Cr+₹31.9 L (5.43%) | L5 | Rejected-Finance BEING NOT L1 |
Tender Value
₹6.2 Cr
EMD Value
₹6.3 L
Closing Date
25 May 2022, 6:00 pmClosed
CE R AND D SECUNDERABAD
CE R AND D SECUNDERBAD OPP JUBILEE BUS STATION PICKET
CONSTRUCTION OF INFRASTRUCTURE FOR DEFICIENT ADMINISTRATIVE ACCOMMODATION ASSEMBLY HALL WITH ANNEXEURE BUILDING AND CAR AND SCOOTER PARKING SHED FOR DIRECTORATE OF SOLID PROPULSION DOSP AT DRDLHYDERABAD
2022_MES_518184_1
CERD/SEC/TOKEN/44 OF 2021-22
Open Tender
Civil Works
Lump-sum
365 days
HYDERABAD
AS PER NIT
8 documents required · 8 mandatory
₹3,000
GE(I) R AND D KANCHANBAGH HYDERABAD
₹6.3 L
Yes
22 Jun 2022
13 Apr 2022
1 Jun 2022
13 Apr 2022
25 May 2022
16 May 2022
14 Apr 2022 - 25 Apr 2022
Amount
Schedule 'A' Part - I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl. item No. 1.01 to 1.05) is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6.
Lumpsum price worked out by the contractor for Construction of Administrative accommodation assembly halland Annexure Building with RCC framed structure /Galvalume sheet roof building, complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Construction of Parking shed-1 for 08 Cars with RCC framed structure, complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Construction of Parking shed-2 for 18 Cars and 12 Scooters with RCC framed structure, complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for Supply,laying and installation of LLDPE septic tank for 50 Users designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundaion, vent shaft, connection with upflow filter including media, complete all as specified and directed and installation shall be done as per manufacturer instructions/ specifications. Note: all civil work required shall be deemed to be included in the quoted rate.
Lumpsum price worked out by the contractor for Construction of Construction of Soakage well of size 1.80 m dia and 3.00 m effective depth, complete all as shown on drawings and as specified.
Lump sum price worked out by the Contractor for “ EXCAVATION, EARTHWORK,SITE CLEARANCE,AREA DEVELOPMENT ” as listed in Schedule ‘A’ Part - II representing _______ % ______________ percent Above / Below the lump sum price of `6,61,841.13 inserted by the MES in Schedule ‘A’ Part - II
Lump sum price worked out by the Contractor for “ ROAD / PATH / CULVERT / HARD STANDING ” as listed in Schedule ‘A’ Part - III representing __________ % ____________ percent Above / Below the lump sum price of ` 30,41,643.94 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “ SEWAGE DISPOSAL ” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of `2,93,569.56 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for " AREA DRAINAGE” as listed in Schedule ‘A’ Part - V representing _______ % __________________ percent Above / Below the lump sum price of `8,08,275.08 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for "INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VI representing _______ % __________________ percent Above / Below the lump sum price of `49,290.56 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VII representing _______ % _________________ percent Above / Below the lump sum price of `14,08,091.86 inserted by the MES in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “ EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VIII representing _______ % _________________ percent Above / Below the lump sum price of `5,81,448.12 inserted by the MES in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part - IX representing ______ % _________________ percent Above / Below the lump sum price of ` 55,619.70 inserted by the MES in Schedule ‘A’ Part - IX
Lump sum price worked out by the Contractor for “ LIGHTENING PROTECTION ” as listed in Schedule ‘A’ Part - X representing ______ % _________________ percent Above / Below the lump sum price of `1,82,882.00 inserted by the MES in Schedule ‘A’ Part - X
Lump sum price worked out by the Contractor for “ REFRIGERATION AND AIRCONDITIONING” as listed in Schedule ‘A’ Part - XI representing ______ % _________________ percent Above / Below the lump sum price of `81,078.08 inserted by the MES in Schedule ‘A’ Part - XI
Lump sum price worked out by the Contractor for “ RAIN WATER HARVESTING” as listed in Schedule ‘A’ Part - XII representing ______ % _________________ percent Above / Below the lump sum price of `84,607.69 inserted by the MES in Schedule ‘A’ Part - XII
Schedule 'A' Part - XIII This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as `0.00 indicates this fact only.The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item No. 14.00 to 76.00
RAIN WATER HARVESTING Boring hole 600mm dia and 10 mtr depth below the ground level in any kind of rock/soil including disposal of surplus soil to a distance not exc 50 metres away all as specified and directed by Engr-in-Charge.
M&L for gravel filling (River stone) of size 40 to 60mm dia in under pit / Bore holes complete all as specified and directed.
M&L for gravel filling (River stone) of size 60 to 100mm dia in under pit / Bore holes complete all as specified and directed.
S&F PVC (SWR) pipe 160mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed.
S&F PVC (SWR) pipe 300mm dia single socketed in any length with rubber ring joints laid in trenches / bore holes complete all as specified and directed.
S&F PVC (SWR) perforated pipe 300mm dia single socketed in any length with rubber ring joints laid in trenches / bore holes complete all as specified and directed.
S&F PVC (SWR) 160mm dia vent cowl complete all as specified and directed.
INTERNAL WATER SUPPLY Supply and fix, two way bib cock, cast copper alloy, chromium plated for size 15mm dia with crutch or butter handle, screwed down for iron pipe complete all as specified and directed.
Supply and fix, health faucet cast copper alloy ,chroimum plated including 1 mtr long pipe, and all fittings to fix screwed down for iron pipe complete all as specified and directed
INTERNAL ELECTRIFICATION Supply and fix, Industrial type High bay 100W LED light fittings IP65 protected luminaire robust open type vertical Highbay luminous efficiency not less than 150 lm/w, CCT 5700K along with not less than 4 KV surge protection, electronic driver inclduing fixing to the ceiling using necessary fastner/hook for hanging the lights and connecting with three core 2.5Sqmm round copper cable from ceiling rose to the connector of the fitting all as specified and directed.
Supply & Fix, Industrial type 2x2 recessed mounted energy efficient LED luminaire 34/36W, with luminous efficacy of 120lm/watt , 5700 K CCT with electronic driver, PIR occupancy sensor suitable for false grid ceiling complete with all accessories prewired and connecting up with three core 1.5sqmm round PVC copper conductor cable complete all specified and directed.
Supply & Fix,Industrial type Security light fitting 25 W IP 66 protection, color temp (Cool White) pressure die cost aluminium body with high power LEDs as light source and inbuilt optics transparent diffuser, inbuilt electronic driver and luminous efficacy of 120lm/watt fixing on the GI bracket of not less than 25mm dia bend to shape as required at site and fixing with nexcessary GI clamps on the wall including connecting up with three core copper cable all as specified and directed.
Supply & Fix,Industrial type 36/40W, 230V, 6500K CCT surface and wall mounted integral LED batten extruded alluminium housing with inbuilt electronic driver and including connecting up with twin core twisted flexible copper condctor cable from ceiling rose to fitting all as specified.
Supply & Fix,Industrial type 20/22W, 230V, 6500K CCT surface and wall mounted integral LED batten extruded alluminium housing with inbuilt electronic driver and including connecting up with twin core twisted flexible copper condctor cable from ceiling rose to fitting all as specified.
Supply & Fix, Industrial type 1x10W, 230V, 6500K CCT surface and wall mounted integral LED batten extruded alluminium housing with inbuilt electronic driver with inbuilt motion sensor including connecting up with twin core twisted flexible copper condctor cable from ceiling rose to fitting all as specified.
S&F indoor industrial type LED Surface mounted for downlight with white powder coated polycarbonate housing and pressure die-cast heat body with heat sink having high efficiency.16W, 6500K CCT, integral elctronic driver complete fixing with all accessories prewired and including connecting up with three core flexible copper conductor cable as required at site with suitable size complete all as specified and directed
Supply and fixing telephone jack 2 way RJ-11 complete all as specified and directed.
S&F ceiling fan of sweep 1200mm,240volts, of not less than 5 star BEE rating, BLDC dust resistant fan connecting up with three core 1.0 Sqmm cable from ceiling rose including required length of down rod as required at site all as specified.
Supply and Fix air circulator fan 450 mm sweep high speed 230V, 50 Hz incluing fixing arrangement wirth MS bracket frame complete all as specified and directed.
Supply and Fix sheet metal enclosure suitable for MCCB 4 pole G-frame including growing with nut bolts, making connection with existing cables complete with lugs, glands all as specified and directed.
M&L Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth lead wire 4 mm dia. by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed , including funnel with GI med grade watering pipe 20 mm bore , wire mesh , charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode , with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar, GI light grade 15mm dia pipe for earth lead protection including necessary excavation earth work in any type of soil and getting out and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I and as directed.
DG SET Supply installation testing and commissioning of silent Diesel Engine driven generating set 415 volts, 125 KVA / 100 KW 3 phase 0.8 power factor 50Hz, 1500 RPM, Liquid Cooled, With all complete all connected acessories in all respects for commissioning of the DG Set, with CPCB approved Accoustic enclosure IP 23, self excited self regulated brushless AC generator installed including accoustic enclosure suitable for ambient condition at Hyderabad including AMF panel and confirming to condition under IS 4722/1460, BS 5514/2613/5000 ISO 8526/3046 with the following :-
Alternator - Standard design alternator, Power Rating 125 KVA/ 100 KW, 3 Phase 4 wire, 415 Volts, 50 HZ, Power factor 0.8(lagging) Current 173.91 Amps, net output at site after considering derating for per site conditions at 0.8 (lagging) power factor, 1500 RPM, Cooling Liquid cooled, Aspiration Turbo charged, air cooled self regulated screen protected drip proof IP 23 enclosure brushless design with widing in pole faces, insulating class 'H' and voltage regulation of +1% at rated voltage from no load to full load, A1 The alternator shall be conforming to BS 2613/5000 and shall be in position to generate supply with frequency regulation with in +1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS-2613/5000/IS-4722.
Diesel Engine : Adequate capacity Diesel Engine suitable for 125 KVA coupled with alternator and after considering derating as per site conditions after generating and reducing power consumed by accessories, directly coupled through flexible coupling, multi cylinder, multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS-5514 with an overload capacity of 10% for one hour in 12 hours continous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessoires shall be as under :- Insulation class - 'H' , Temperature rise class - 'H' ,Excitation- Self excited Regulation performance - The voltage is kept constant with + 1%, manual voltage adjustment with in + 5%. , Frequency Regulation + 1% Suitable size & suitable number of runs of UG copper cable (Control cable) from Alternator to AMF & RAW Power to AMF Panel is deemed to be include is quoted rate.
(i) Flywheel with housing (ii) Cooling System : Mounted radiator with fan and belts (iii) Cooling Water Pump : Centrifugal type belt driven (iv) Exhaust System : As per OEM reccommendation/specification. (v) Starting System :- Electric Self Starter with maintenance free batteries including battery charging alternative belt driven. (vi) Batteries :- 12 Volts DC electrical batteries of suitable AH rating, complete connected with copper cable PVC sheathed conductor multistranded leads of suitbale length from self starter to the battery terminals complete with initial charge all as specified and directed. (vii) Fuel tank of adequate capacity :- As per OEM norms and specifications designed for above capacity of DG Set.
AMF Panel : Auto Main Failure (AMF) Panel made out 3.15mm thick CRCA sheet weather proof powder coated conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase, 4 wire AC 50 HZ having aluminium bus bar of capacity required to carry current at 100% load of 125 KVA DG Set with three phase and half neutral colour coded pre-wired with copper flexible cable, all as specified with the following accessories, control cable from Gen Set to AMF Panel.
Contactor of Suitable capacity 3 pole with required nos as per OEM, TP contactor for netural for both supplies Suitable capacity of MCCB, 4 Pole for both supplies CTs 150/5A for both the supplies Push buttons Indication Lamps
2 over load + earth leakage relay Multi functional digital meter for KWH, KVA, KW, Amps, Volts, frequency, power factor etc. SMPS Battery charge 12V, with trickle and boost charging. ON/OFF Switch. Automatic/Manual Switch. Hooter. Voltage sensing relay. Six window anunciator for fault indications.
Acoustic Enclosure : Enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet metal will provide easy access for maintenance, repairs and operation. The enclosure is custom to suit conditions, with the following features :-
(i) Custom built product for various equipments, with ensure the optimum performance without duration. (ii) 16 SWG (1.6mm) thick CRCA sheet to be used for enclosure panel to ensure longer life against weathing action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absoption. Acoustic layers are supported by perforated sheets. (iii) Sheet metal component of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against weathering action. (iv) Special paint treatment with pure polyster powder/epoxy to be provided for better weather resistance. (v) Well designed ventilation system to be provided to put out the heat from the chamber efficiently. (vi) For effective acoustic/weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used.
(vii) Working space is to be provided around the equipment for easy maintenance/repairs. (viii) Necessary cut out provision for entry and exist of fuel lines cable to be incorported in the enclosure as per the requirement. (ix) See through transparent window(glass or acrylic) in front of engine panel to be provided for monitoring the operation. (x) Ducting if required, bellows, mechanical hardware like locks, hinge, fasters etc to be provided. (xi) Deliverables 75 DB @ 1 meter at 75% load under free field conditions. The temp inside the enclosure will be with in limit and as per manufacturers recommendations above ambient temp. (xii) The enclsoure should be provided with bulk head light fitting for inside illumination. (xiii) The exhaust pipe along with proper aluminium cladding, shall be laid to a height of above the roof level. The rates for the same are to be included in the quoted rates.
(xiv) The batteries should be placed inside the enclosure inside the DG Set on a suitable insulated platform. (xv) The DG set should be provided with external emergency stop push button. (xvi) Provn of 2 Nos 11 Watts LED lamp fitting of approved Make incl wiring inside canopy with single switch controlled. (xvii) Fuel gauge to be provided with the neck of fuel tank. (xviii) Tools as per manufacturers with the box. (xix) Invents of suitable company be manufacture. (xix) The acoustic enclosure parts shall be of powder coated after pre treatment process.
(e) Civil Work : All civil works including RCC/ PCC platform 1:2:4 type B 1 and related to foundations including of panel and equipments including of panel and equipments including making good and existing structure of disturbed during installation and commissioning of Gen Set, The depth of the foundation shall be minimum 300mm with anti vibration pads or as recommended by the manufacturer. The foundation drawing for DG Set shall got be approved by Engr-In-Charge before laying of foundation. The Contractor has to obtain approval for RCC/PCC foundation for the DG Set with the manufacturers, Rates shall be quoted accordingly with written certificate from the manufacturers for the same.
Speed of operations shall be as below :- Hoist 3 m / min Cross Travel 6 m/ min Long Travel 8 m/ min
The crane shall be provided with main and micro motions through V3F drive including the required accessories with standard provision for over load and short circuit micro driver with control panel, power and controlling cables confirming to relevant IS including of steel rope as per IS 2266 with 4 fall. The crane shall confirm to latest IS 807/3177/3938 and other relevent IS as indicated in detailed specfications for EOT cranes.
Specification as follows: (i) Girders box type section fabricated using fresh tested steel plates to IS: 2062 Gr ‘A’ obtained directly from Main steel producers (like SAIL, RINL, TISCO, Vizag steel), cut to size using the latest CNC profile cutting machines and welded using modern welding practices. All welds shall be subjected to radiography to ensure defect free welds. (ii) Hoisting Mechanism, with specially designed crab unit for double girder, engineered for smooth jerk free, and soft start, lifting of loads. Hoist drive with micro drive through VVVF drives. The rope drum shall be made out of seamless pipes fabricated from plates tested as per ASTM/IS standards.
(vii) Controls: The crane shall be controlled by pendant push button type . The main electrical components shall be housed sheet steel enclosures suitable for indoor application conveniently located for easy maintenance. Standard protection devices for overload protection and short circuit protection shall be provided. viii) All other incidental, Civil , Electrical and Mechanical works Notes for item No 36.01 above : 1. The subject crane is meant for the purpose of handling small to medium components/materials. 2. The crane will be put to use for all working days’ continuous duty with CT, LT and Hoist movements. 3. The department shall be responsible for providing suitably rated electrical outlet in the Main Electrical Control Panel/Main Distribution Board of the buildings . All other works, electrical earthings and associated incidental and minor works shall be the responsibility of the contractor. 4. The details of RCC brackets, End plates etc are shown in relevant drawings. The contractor shall certify that these are sufficient and meets the requirements of his design.
5. The shop floor environment will be dust prone, humid, welding fume filled and ambient temperature going up to 50ºC. Weather conditions are tropical. Crane shall be kept in the normal shop floor condition without any temperature controlled enclosure / shop. Max. temperature variation is 25 deg Celsius in 24 hours. Sound level should be minimum and the crane should have decent aesthetic look. Ambient Temperature: 4º C - 50º C & relative Humidity: 55%. 6. Major Technical specifications of the crane are given below. These are to be complied with by the contractor/manufacturer. The parameters which are not specified are to be as per Contractors'/OEM's own design. The contractor shall submit following drawings, giving all design parameters and get the drawings approved from the Accepting Officer. The drawings shall be complete in all respect. (a) General Arrangement (GA) Drawing of the Crane (for approval) (b) GA Drawing of Hoist / Trolley (for approval) (c) Calculations for Bridge Girder. (d) GA Drawing of Individual Mechanisms (for approval) (e) Drawings of Bridge, End-Carriage, Leg and their connections
STRUCTURAL FABRICATION (Constructional Details): Bridge Girder: Shall be of Double Girder Box Type construction having Minimum vibrations. End Carriage: Fabricated from rolled steel sections / plates as per IS:2062 . Raw Material: Only tested quality steel Fe 410 WB as per IS-2062, IS:1964 & IS:808 and certified for quality by reputed inspection authorities, shall be used. Number of Joints allowed: Single Joint , Welding Electrodes for all Horizontal Welding: E 7018 Electrode only should be used. Welded Joint Testing: All Butt Welded Joints (both compression/ tension and flanges / web joints)shall be Radiographically test results, X-ray filims to be produced for evaluation and form part of the completion documentation). Mechanical Joints: Fit Bolts (as per IS 3640 –1982) for all joints coming in main members.
Heat Treatment & NDT Examination: The Trolleys shall be stress relieved, if necessary, by thermal heat-treatment process after welding & NDT. All welding shall be tested by NDT means [MPI, LPI & RT] after stress relieving operation (Govt. approved Test House & certificate). Manufacturer to furnish the details of facilities for Heat Treatment furnace & NDT Lab at their works. All the welded joints should be NDT tested by Govt. approved Test House & certificate / X-Ray films to be submitted at time of inspection. Gear & Gear Boxes Details: Gear Box should be of fabricated type duly stress relieved. Pinions made of EN 24 and gears of EN 18. Gears in all the Stages shall be helical in design and to be of machined, lapped and hardened Straight and helical spur gearing shall normally be used for all motions. Worm and bevel gears shall not be used. First and high speed reductions shall be through helical gears. All first reduction pinions and also the other pinions if feasible shall be integral with the shafts. All gears shall be of hardened and tempered alloy or carbon steel with machine cut teeth. Gear tooth shall be cut in metric module system. Surface hardening of teeth is not allowed.The Gears / pinions should be hardened to HRC 50-55 and ground. Please note that gears and pinions must have pressure angle of 20° only.
Lubrication: Suitable lubrication system shall be provided for gear box, all rotating parts wherever applicable. Details of the same to be furnished. Please indicate the type of Lub. Oil & grease, quantity also. Rope Drum: Shall be of fabricated type stress relieved or seamless pipe. The circumferential weld joints shall be tested by 100% X-Ray quality/ Radiogrphycally.The size of the drum shall be designed as per IS standards. Wheel : Trade mean dia of wheel for cross travel shall be designed as per IS standards forged steel and for long travel designed as per IS standards forged steel. Type of Coupling: Couplings should be flexible geared Barrel type. No pin / bush / rubber type coupling to be used Machining Operation: All mechanical mating surfaces and wheel seating areas are to be machined to the required finish and protected. Hoist Wire Rope Details: confirming to IS: 2266. Mention Wire rope 8 mm dia, No. of fall -04, 6x36, constructions , Fibre core . Make:- USHA MARTIN. Input Power Supply: Shall be 415 ± 10% Volts, 50 ± 3% Hz, 3 Phase, AC. Control Voltage: Shall be 110V AC
Protection: All Panels, Limit-Switches and Motors shall have IP 54 protection. Motor Details: Squirrel Cage Induction Crane duty motors, Totally enclosed, fan cooled, Insulation Class-F & confirming to relevant latest IS:325, and IS-123, S4 duty, 150 starts per hour and 40% CDF. Contractor to provide other details like No. of motors, capacity of motor, Frame size, make, type and No. of poles etc. Type & details of Brakes for all motions: "Fail to safe" action type Hydraulic thruster / disc brakes type to be provided to hold the mechanism in position instantaneously as soon as the power supply is 'OFF' either accidentally or intentionally for all motions. Brake wheel dia for hoisting shall be designed as per IS standards Electric Contactors: shall have SIEMENS / L&T / GE contactors suitable for Crane operations. Crane duty AC-4 ratings. Contactors Rating: The rating of all Contactors shall be at least 50% higher than the respective electric motor full load current, at the specified duty cycle. Wiring: All the panel wiring should be done by using standard multi core Copper highly flexible, double insulated cables and of Butyl Rubber.
Earthing for Electrical items in Crane: Shall be carried out as per IS. Trailing Cables: Trailing cables (Extra flexible having copper conductors only) should be traveling on rollers moving on separate I- Beam parallel to Bridge Girder and both for LT & CT shall be supplied and Erected by supplier. Illumination: 2 Nos. of 90W LED lamps & light fittings shall be provided under the Bridge and 1 No. shall be provided under CT Trolley. Fittings shall be of non-integral type. (Total lights 3 Nos.). Limits Switches: Hoist shall be provided with both rotary and counter weight type (Over Hoisting and Over lowering) Shunt, adjustable type limit switches. Limit switches shall be provided for both CT & LT. Two way lever type for CT both direction and LT both direction. Supply and Erection of DSL Shroueded busbar : The details of DSL to be provided by contactors for CT & LT and in scope of work. Remote Control: Push Button Type Radio Remote control for all motions shall be supplied. Radio remote control should be multi speed steps of operation. The unit work with rechargeable batteries. Battery charger to be provided along with the unit & rechargeable batteries.
Supply and Fix sheet metal enclosure made out of 2 mm thick suitable for MCCB 4 pole, 40 Amps, complete all as specified and as directed.
REFRIGERATION AND AIRCONDITIONING Supply installing, testing and commissioning of 1.5 TR capacity Split type air conditioner unit (Inverter type) 5 star rated complete with drive motor, air cooled condenser with all accessories varied speed and dual rotary compressor, including fixing the outdoor unit with powder coated MS stand/PCC base and fixing of indoor unit on wall including core cutting of required size on type of wall and making good of disturb surface, providing and making interconnection, including refrigerant piping with nitryle rubber insulation and control cable from indoor to outdoor up to a distance of 3.0 mtrs, power cabling (max 3.0 mtrs from isolator/enclosure) to units, first charging non CFC/non HCFC R-32 of refrigerant gas including cord less remote, PVC drain pipe of 25mm dia for connecting drain lines from indoor unit to maximum of 3.0 mtrs to nearest drain points complete all as specified and as directed.
Supply installing, testing and commissioning of 2 TR capacity Split type air conditioner unit (Inverter type) 5 star rated complete with drive motor, air cooled condenser with all accessories varied speed and dual rotary compressor, including fixing the outdoor unit with powder coated MS stand/PCC base and fixing of indoor unit on wall including core cutting of required size on type of wall and making good of disturb surface, providing and making interconnection, including refrigerant piping with nitryle rubber insulation and control cable from indoor to outdoor up to a distance of 3.0 mtrs, power cabling (max 3.0 mtrs from isolator/enclosure) to units, first charging non CFC/non HCFC R-32 of refrigerant gas including cord less remote, PVC drain pipe of 25mm dia for connecting drain lines from indoor unit to maximum of 3.0 mtrs to nearest drain points complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA complete all as specified and as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified and as directed.
LIGHTNING PROTECTION, STANDBY DGSET & EXTERNAL ELECTRIFICATION M & L Earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm buried directly in ground ( earth pit not less than 2.25 m deep bellow ground level ) with top edge of the plate not less than 1.5 m bellow normal ground level, connected to galvanized earth strip 32X6 mm by means of galvanized iron or steel bolts , nuts , check nuts and washers, and connected to equipments as directed, including funnel with GI med grade watering pipe 20 mm bore , wire mesh, charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with concrete pit in PCC 1 : 3 : 6 type C-1 , 50 mm thick pre cast RCC 1 : 2 : 4 type B-1 cover slab reinforced with 8 mm dia deformed bar 15 cm C/C and suitable handle of 10 mm dia round bar ,GI light grade 40mm dia pipe for earth lead protection including necessary excavation earth work in any type of soil including getting out and disposal of spoil to a distance n.exc. 50 m and necessary testing complete all as shown on electrical plate No. 3 of MES SSR Part-I all as specified and directed.
Supply , install test & commission of LT Panel in door type confirming CPRI standards, Cubicle type, factory fabricated out of CRCA Sheet of 2.0 mm thick dust, vermin proof, weather proof, IP-54 Grade of protection with both side opening and locking arrangement including providing busbar chamber for connecting outgoing cables made with AI bus bar of capacity 600 Amps rating for 415 V 50 Hz 3 Phase system including internal wiring using suitable size not less than 1.5 sqmm FRLS copper conductor cable along with ferrules. The panel shall be painted with anticorrosive coating and finally epoxy polyester powder coating of flint gray shade (RAL -7032). the panel should be mounted on 'C' channel base of required size duly coated with anti corrosive paint. the circuit distribution lines to be marked over the panel using poly venyl reflective stickering complete with following :-. INCOMING (a) MCCB 320 A, 4P, 36KA with microprocessor release, Ics=100% of Icu with adjustable overload setting -01 OUT GOING (a) AI busbar 4 wire 440 V 50 Hz, of current carrying capacity 600Amps fixed on epoxy insulators duly colour sleeved.-01
Material and Labour for cutting existing road/PCC of size 45cm x 60cm for taking out/laying of underground cable and including necessary earth work and making good to match with the existing surface with PCC 1:3:6 type CI using 20mm graded aggregates complete all as specified and directed
Labour for removal and re-laying of HT UG cables laid at site in trenches complete for re-routing all as specified and directed.
Supply & fix SMC junction box light weight double door pole mounting for down side connection of sizes 160x160x105mm including MCB DP 10/16 Amps with necessary MCB, mounting enclosure complete necessary 8way connector for looping in loopout cable connection, clamps and suitable glands for cable all as specified and directed by Engr-in-Charge.
Supply and fixing of copper cable of size 3 runs 2.5 Sqmm, PVC insulated sheathed, multistranded copper conductor from junction box to fitting complete all as directed
S&F LED street light 36 W made in pressure die cast housing and heat shrink in aluminium extrusion and IP 66 protection, 5700K color temperature with luminous efficacy not less than 110Lm/watt fixing alongwith the mast arm of street light pole with nucessary nuts and bolts as required at site complete all as directed.
Dismantling of LT over head line with insulator and ACSR conductors and connected items all as specified and directed.
ARBOURICULTURE Clearing grass and removal of rubbish upto a distance of 50 mtr outside the periphery of area cleared complete all as specified and directed.
Preparation of ground by trenching in all type of soils upto a depth of 30 cm including removal & stacking of serviceable material than disposing the surplus soil with all lead & lifts, by spreading and leveling neatly. Making up the trenched area well leveled by filling with additionally supplied earth,complete all as specified and directed.
Rough dressing of trenched ground including breaking clods & flooring with water complete all as specified and directed.
Removal of weeds / unwanted grass (Motha etc) with roots & disposal of uprooted material, stone, rubbish etc. with all lead & lifts complete all as specified and directed.
Fine dressing of ground spreading and mixing with the good earth (excavated / imported) & Manure (organic manure / cow dung / Sludge) in the ration of 8:1 (08 part of stacked volume of good earth & 01 part of stacked volume of manure). Cost of manure / sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8 % stacked volume of manure. Each pit to be mixed with ant termite chemical / granules Thimet 10 G @ 50 – 100 gms / pit. If termite persists repeat the treatment after 06 months by surface spreading the chemical complete all as specified and directed.
Supply of Korean carpet grass by laying direct matting complete all as specified and directed.
Maintenance of lawn area, green & weed free for 01 Month with standard specification.
SHRUB PLANTATION (SOLO) Digging pits in all type of soils and refilling the same the good earth (excavated / imported) & manure (Organic manure / cow dung / Sludge) in the ration of 5:1 (05 part of stacked volume of good earth & 01 part of stacked volume of manure). Cost of manure / sludge and good earth if needed tobe paid separately, after reduction of 20% of stacked volume of good earth & 8 % stacked volume of manure. Each pit to be mixed with ant termite chemical / granules Thimet 10 G @ 50 – 100 gms / pit. Name : Hexora, Nerium speces, Hibiscus spon.
SHRUBBARY PLANTATION Digging pits in all type of soils and refilling the same the good earth (excavated / imported) & manure (Organic manure / cow dung / Sludge) in the ration of 5:1 (05 part of stacked volume of good earth & 01 part of stacked volume of manure). Cost of manure / sludge and good earth if needed tobe paid separately, after reduction of 20% of stacked volume of good earth & 8 % stacked volume of manure. Each pit to be mixed with ant termite chemical / granules Thimet 10 G @ 50 – 100 gms / pit. Name : Tikoms gadickowd, Uphorbia,Vukorosia.
Maintenance, replacement of sapling, causalities etc
HEDGE PLANTATION: Digging trenches of approved / desired size of L&W (45-50 Cms) X D (30-60 cm) in all type of soil . Railing the trenches with good earth (excavated / imported) Mixed with manure (cow dung / sludge / dump) in the ratio of 5:1 (05 part of good earth and 01 part of manure by stacked volume). Cost of manure / sludge and good earth if needed to be paid separately after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. For Termite treatment and Thimet 10G granules @ 100 gms / running mts. Flooding the trench with water and than rough & fine dressing of trenched area including removal of undesirable weeds & vegetation. Supply & plantation of approved varieties of hedge plant saplings. It should be well grown, fully established & disease free. Different colours of pernial flower plants Name : Durauta, Akalysha red or couloued.
Maintenance the hedge by regular watering, trimming & pruning etc for 30 days initially complete all as directed.
BRICK EDGING: Edging with bricks (class-I) laid in (1:2:4), length wise, including required excavation, refilling, consolidating with hand packing and spreading surplus earth neatly within all lead and lifts complete all as directed.
Supply only FLOWER BED (ANNUAL): Blue moon, Exora Dwaul.
Supply Only FLOWER BED (SEASONAL) : Marigold, White lilly.
TREE PLANTATION (a) Digging pits in all type of soils and refilling the same with the good earth (excavated/imported) & manure (organic manure/cow dung/sludge) in the ratio of 3:1 (03 part of stacked volume of good earth & 01 part of stacked volume of manure). Cost of manure/sludge and good earth if needed to be paid separately, after reduction of 20% of stacked volume of good earth & 8% stacked volume of manure. Each pit to be mixed with ant termite chemical/granules, Thimet 10G @ 100-200 gm/pt.Avenue/flowering trees Pit SIZE 1mts x 1 mts x 1 mts (L X W x D)
(b) Each pit to be added with 100 ms of Thimet 10 g granule, to control termite attack (repeat the treatment after 06 months, if termite persists.) flooding the pit basin with water, dressing including removal or rubbish & surplus earth, if any, with all lead & lifts.
(a) Supply and Plantation of approved varieties of healthy, disease free, stout stem & well developed root system tree sapling of 5’-6’ height, with a clear minimum height of 4’-5’ from basin / ground level, after plantation. Staking the tree sapling upto ¾ height with appropriate strength of bamboo stick. Lower 1 feet of stake portion should be treated with anti-termite chemical. Trees : Royalpalece,
(b) Maintenance of tree sapling, after plantation for 30 days or more as minimum guarantee period, for well establishment of tree sapling. Stacking to be continued till free sapling attains the stem strength. Replacement of saplings causalities immediately.
Potted Plants (Indoor): Supply and arranging of healthy grown up plants in plastic pots( Pots of 12” size with bottom plates.) includingMaintenance includes regular watering, loosening of soil, manuring with organic manure and fertilizer mixture, spraying of insecticide and fungicide as and when required trimming and removal of dried leaves and decayed parts of plants to keep them in presentable shape for a period one year. 1. Aracapalms - 10 Nos. 2. Ficusresnold - 10 Nos. 3. Furcriaearievated -10 Nos. 4. Ficausnuda -10 Nos. 5. Asparagussprengeri -10 Nos.
Potted Plants (Outdoor): Supply and arranging of healthy grown up plants in plastic pots( Pots of 12” size with bottom plates.) includingMaintenance includes regular watering, loosening of soil, manuring with organic manure and fertilizer mixture, spraying of insecticide and fungicide as and when required trimming and removal of dried leaves and decayed parts of plants to keep them in presentable shape for a period one year. 1. Bird of Paradise - 10 Nos. 2. Mussaenda - 10 Nos. 3. Bougainvillea -10 Nos. 4. Exora -10 Nos. 5. Eufhorbia Hybrid -10 Nos.
GOOD EARTH / COW DUNG MANURE: Supply and stacking of good earth / manure from approved source / field of approved quality / Ph & suitable for plantation work with all leads, lifts, carriage and royalty / taxes etc. Cost of good earth to e paid separately
Supply only GI tubing 15mm dia
Waste disposal and handling charges complete all as directed.
EXTERNAL WATER SUPPLY M&L for construction of valve chamber of size 600x600x600 mm internal size suitable for valves with PCC 1:4:8 type D2 for foundation and brick masonry wall in cement mortar 1:6 PCC 1:3:6 TYPE C1 for coping rendering in CM 1:4, 15 mm thick including provision of mild steel sheet cover 3.15 mm thick on 40x40x6 mm angle iron frame work with two coats of synthetic enamel black paint over a coat of red oxide primer and locking arrangement including necessary excavation earthwark all as specified and directed.
Cutting of existing GI pipe of size 50 mm dia for taking branch connection and screwing including providing GI fittings as required at site
UPS Supply, Install, testing and commissioning of UPS (uninterruptible Power Supply) of capacity 20 KVA, 3 Phase, AC, Input 300 to 450 volts, 3 Phase output 415 volts +_ 1%, 50Hz to provide 30 Minute backup complete with suitable battery bank of suitable capacity including cable connections as required for complete system and all as specified and directed. (i) 20 KVA/240 VDC online UPS system which is suitable for 3 : 3 with in built isolation transformer -01 No. (ii) 12 V 65 AH SMF batteries -34 Nos (iii) Suitable MS rack for battery interlink for batteries (with UNINYVIN Cables & 3D Lugs) -01 No.
Sukhdevraj Sharma Engineers & Contractors Pvt Ltd
R. Wadhumal and Sons
M/s. P S REDDY
VERMA BROTHERS
Dwarka Pershad Radhey Ramanlal
B.N.S Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .