Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹24.5 LAccepted-AOC | ₹24.5 L | 1 | Accepted-AOC Being L1 |
| 2 | 2₹34.1 L+₹9.7 L (39.4%)Rejected-AOC | ₹34.1 L+₹9.7 L (39.4%) | 2 | Rejected-AOC Not Being L1 |
| 3 | 3₹38.9 L+₹14.4 L (58.9%)Rejected-AOC | ₹38.9 L+₹14.4 L (58.9%) | 3 | Rejected-AOC Not Being L1 |
| Sl No | Description | Qty | Unit | M/s. Rishav Sood L1 | M/S MALHI CONSTRUCTIONS L3 | R.K.CONSTRUCTION ENGINEERS L2 |
|---|---|---|---|---|---|---|
| 1.00 | Supply ,Installation ,commisissing ,testing of dual FCBC (Float Cum Boost Controlled) 48 V 400 Amp 3 phase, 6 feeder battery charger and DC Distribution board in common cubicle complete with accessories. The charger is suitable for 415V +/- 10% AC input and the output is suitable to charge of 48V DC 800AH batteries and also supply load. The output voltage remains constatnt within +/- 2 % for AC input voltage variation 415 +/- 10% and Load variation 0-100%. Current Rating :400A Make: Statcon Energiaa/Baid power services (BPS)/Apex | 1 | Each | 6,90,000 ₹6,90,000 Lowest | 14,50,000 ₹14,50,000 | 13,00,001.11 ₹13,00,001.11 |
| 2.00 | Supply and install, DC distribution board ( 6 feeder) 48V made out of 3.0mm thick CRCA sheet epoxy coated, dust and vermin proof floor mounted with and including suitable size 40x5mm MS angle Iron stand duly painted and comprising of the following accessories :- (a) Incomer DC MCCB 400A - 01 No. (b) Outgoing - 06 Nos DC MCCB of 100A - 06 Nos for 6 feeders (c) Electrolite Three phase and neutral copper bus bar 600A. (d) DC voltmeter and Ammeter with shunt (e) Indicator lamps, and cable entry with gland plate all as specified and directed. | 1 | Each Job | 1,50,000 ₹1,50,000 Lowest | 2,40,000 ₹2,40,000 | 2,75,001.11 ₹2,75,001.11 |
| 3.00 | Supply, Installation, Commisissing, for sealed maintenance free VRLA battery bank 48 Volt. 800 AH consisting of 24 Nos. Cell of 02 Volt each complete with inter-cell copper connector, SS Nut bolt, MS Powder coated stand in factory charged condition all as per specified and directed. Make : Amara Raja Quanta/Exide Power safe or equivalent make of Amaron | 2 | Each Set | 5,20,000 ₹10,40,000 Lowest | 7,35,000 ₹14,70,000 | 6,25,001.11 ₹12,50,002.22 |
| 4.00 | Battery rack made out of 40x5mm angle iron and FI strip 5.0mm thick & connecting cable for SMPS all as per specified and directed. | 2 | Each | 10,000 ₹20,000 | 25,000 ₹50,000 | 2,001.11 ₹4,002.22 Lowest |
| 5.00 | Supply and fix copper wound voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 320 V to 480V with output voltagestabilized at 415V suitable for 48V 400A charger load with accuracy + 1% and speed of correction 8 volts per second and of capacity 50 KVA with over/under voltage and overload and single phase protection with input and output volt and ammeters.all as per specified and directed. | 1 | Each | 1,95,000 ₹1,95,000 Lowest | 3,00,000 ₹3,00,000 | 2,50,001.11 ₹2,50,001.11 |
| 6.00 | M & L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized iron strip 32X6mm by means of nuts bolts,washers,check nuts of GI steel all as shown in electric plate no 3 of SSR -2009 Part II, all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe medium grade 40mm and GI watering pipe 20mm light grade with funnel and wire mesh ,40mm thick pre-cast RCC N-15 (nominal mix) cover reinforced with XPM weight not less than 4 kg /sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover ,PCC M-15 (nominal Mix) pit,excavation and earth work in any type of soil and connected all as specified and as directed. Note: On testing after completion of the result not found below 5 Ohms earth resistance is not obtained the earthing will be redone at no extra cost. | 6 | Each Set | 5,000 ₹30,000 Lowest | 6,000 ₹36,000 | 6,001.11 ₹36,006.66 |
| 7.00 | M&L for copper plate chemical earthing with elecrolyte copper earth plate of sixe not less than 90cm x 60cm x 5 mm burried vertically in excavated pit not less than 2.25 m deep below normal ground level and top edge not less than 1.25 mtr below normal ground level connected to the copper strip 32x6mm size by means of brass nut/check nut/bolts/washers including 40mm dia GI protection pipe and 20MM dia GI water pipe with funnel and wiremesh surrounded with approved non corrosive conductive chemical backfill compund (Bentonite/graphbite based conductive compund not less than 200 kg/per earthing) including inspection chamber with brick work (size not less than 30cmx30cmx30cm internal dimensions) and RCC cover with lifting handle and incl earth testing terminal block connected to earth dolly/main earthing of equipment or as directed including all earth work a in any kind of Soil complete all as specified and directed by Engineer-in-Charge. Note - Copper strip and 40mm dia medicum grade GI pipe upto 12 mtr length shall deemed to be included in quoted rate.
(ii) Resistance of earthing shall be less than 1.0 Ohm failing which the contractor will do earthing again to achived the desired result without any extra cost. | 2 | Each Job | 70,000 ₹1,40,000 | 45,000 ₹90,000 | 42,001.11 ₹84,002.22 Lowest |
| 8.00 | Supply and fixing of submain wiring alongwith earth copper conductor multistranded FR-LSH PVC insulated unsheatehed cable 1100volts conforming to IS:694 for size of 2 x 10 sqmm as Phase, Neutral and 1 x 10 sqmm as earth conductor all specified and directed.
Note : (i) Two single core cable and one run of earth copper cable will be measured and paid as one unit length | 100 | RM | 650 ₹65,000 | 450 ₹45,000 Lowest | 601.11 ₹60,111 |
| 9.00 | S & F Anti stat matting 3 mm thick all as directed | 100 | Sqm | 750 ₹75,000 Lowest | 1,400 ₹1,40,000 | 1,001.11 ₹1,00,111 |
| 10.00 | M&L sub main wiring with two single core PVC-FRLS insulated unsheathed multistranded copper conductor cable of size 4 sqmm in concealed conduit/laying on surface batten /including conduit and accessories with 2.5 Sqmm PVC-FRLS insulated unsheathed multistranded copper conductor as a continuous earth wire complete all as specified incl taking down old unserviceable sub main wiring complete
Note : (i) Two single core cable and one run of earth copper cable will be measured and paid as one unit length | 70 | RM | 325 ₹22,750 Lowest | 350 ₹24,500 | 351.11 ₹24,577.7 |
Tender Value
₹26.7 L
EMD Value
₹53,380
Closing Date
23 Jul 2026, 6:00 pmClosed
CWE YOL
HEADQUARTERS COMMANDER WORKS ENGINEER YOL
PROVN OF POWER SUPPLY FOR PROJECT ASCON PH-IV IN SIG COY AT DALHOUSIE CANTT UNDER AGE(I) DALHOUSIE.
2026_MES_774681_1
CWE/Y-48/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DALHOUSIE
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
AGE (I) DALHOUSIE
₹53,380
Yes
14 Sept 2026
25 Jun 2026
30 Jul 2026
25 Jun 2026
23 Jul 2026
9 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply ,Installation ,commisissing ,testing of dual FCBC (Float Cum Boost Controlled) 48 V 400 Amp 3 phase, 6 feeder battery charger and DC Distribution board in common cubicle complete with accessories. The charger is suitable for 415V +/- 10% AC input and the output is suitable to charge of 48V DC 800AH batteries and also supply load. The output voltage remains constatnt within +/- 2 % for AC input voltage variation 415 +/- 10% and Load variation 0-100%. Current Rating :400A Make: Statcon Energiaa/Baid power services (BPS)/Apex | 1 | Each | - | - |
| 2 | Supply and install, DC distribution board ( 6 feeder) 48V made out of 3.0mm thick CRCA sheet epoxy coated, dust and vermin proof floor mounted with and including suitable size 40x5mm MS angle Iron stand duly painted and comprising of the following accessories :- (a) Incomer DC MCCB 400A - 01 No. (b) Outgoing - 06 Nos DC MCCB of 100A - 06 Nos for 6 feeders (c) Electrolite Three phase and neutral copper bus bar 600A. (d) DC voltmeter and Ammeter with shunt (e) Indicator lamps, and cable entry with gland plate all as specified and directed. | 1 | Each Job | - | - |
| 3 | Supply, Installation, Commisissing, for sealed maintenance free VRLA battery bank 48 Volt. 800 AH consisting of 24 Nos. Cell of 02 Volt each complete with inter-cell copper connector, SS Nut bolt, MS Powder coated stand in factory charged condition all as per specified and directed. Make : Amara Raja Quanta/Exide Power safe or equivalent make of Amaron | 2 | Each Set | - | - |
| 4 | Battery rack made out of 40x5mm angle iron and FI strip 5.0mm thick & connecting cable for SMPS all as per specified and directed. | 2 | Each | - | - |
| 5 | Supply and fix copper wound voltage stabilizer for automatic operation, three phase, naturally oil cooled, indoor type & designed for input variation between 320 V to 480V with output voltagestabilized at 415V suitable for 48V 400A charger load with accuracy + 1% and speed of correction 8 volts per second and of capacity 50 KVA with over/under voltage and overload and single phase protection with input and output volt and ammeters.all as per specified and directed. | 1 | Each | - | - |
| 6 | M & L for earthing complete with galvanized steel earth plate electrode 600x600x6mm thickness not less than 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized iron strip 32X6mm by means of nuts bolts,washers,check nuts of GI steel all as shown in electric plate no 3 of SSR -2009 Part II, all as specified and indicated complete and including charcoal dust,salt etc and GI protection pipe medium grade 40mm and GI watering pipe 20mm light grade with funnel and wire mesh ,40mm thick pre-cast RCC N-15 (nominal mix) cover reinforced with XPM weight not less than 4 kg /sqm with suitable handle of 6mm dia MS bar and angle iron 40x40x3mm frame for cover ,PCC M-15 (nominal Mix) pit,excavation and earth work in any type of soil and connected all as specified and as directed. Note: On testing after completion of the result not found below 5 Ohms earth resistance is not obtained the earthing will be redone at no extra cost. | 6 | Each Set | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
E-tender48.pdf
Tender Documents • 1.24 MB
BOQ_867454.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .