| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC DESHBANDHUPARA PO SILIGURI TOWN DIST DARJEELING PIN 734004 | JALPAIGURI | WEST BENGAL | 734004 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹41.8 L+₹2.0 L (5.09%)Rejected-Finance A 4 VIVEKANANDA SUPER MARKET 2ND FLOOR HILL CART ROAD SILIGURI 734 001 DIST DARJEELING W B | JALPAIGURI | WEST BENGAL | 734001 | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹46.1 L+₹6.3 L (15.9%)Rejected-Finance EAST VIVEKANANDA PALLY MANGAL PANDEY SARANI PO RABINDRA SARANI SILIGURI 734 006 WB | JALPAIGURI | WEST BENGAL | 734006 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹46.2 L+₹6.4 L (16.1%)Rejected-Finance 30 HAREN MUKHERJEE ROAD HAKIMPARA SILIGURI 734 001 DARIEELING WB | DARJEELING | WEST BENGAL | 734001 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹46.3 L+₹6.6 L (16.5%)Rejected-Finance GEETANJALI COMPLEX B BLOCK 2ND FLOOR MUKUNDA DAS ROAD MILANPALLY SILIGURI 734405 DARJEELING | SILIGURI | DARJEELING | WB | 734405 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
1 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Sukna
Garrison Engineer Sukna, Post-Simulbari, Dist.-Darjeeling, WB-734009
REPAIR MAINT OF LT ELECTRIC SUPPLY DISTRIBUTION AND ALLIED WORKS UNDER ADALPUR POWER HOUSE UNDER AGE E/M OF GE SUKNA
2024_MES_637001_1
GE Sukna/8628
Open Tender
Civil Works
Works
270 days
Sukna
as per tender documents
8 documents required · 8 mandatory
₹500
GE Sukna
₹90,000
Yes
15 Mar 2024
11 Jan 2024
3 Feb 2024
11 Jan 2024
1 Feb 2024
25 Jan 2024
12 Jan 2024 - 1 Feb 2024
Amount
Taking down cement plaster on brick or concrete surfaces / ceiling, racking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
M & L for 15 mm thick rendering in cement mortar 1:4 on other than fair faces of brick work or stone masonry or on one side of lathing surfaces and finished the surface even and smooth without using extra cement complete all as specified and directed. Note:- WPC shall be measured and paid separately.
M & L for 15 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces and finished the surface even and fair without using extra cement complete all as specified and directed.
M & L for 10 mm thick rendering in cement mortar 1:3 on fair faces of brick work or concrete ceiling surfaces and finished the surface even and fair without using extra cement complete all as specified and directed.
M&L for repair to broken/damaged RCC chajjas by making good with PCC 1:2:4 type B1 or rendering 15 mm thick in cement mortar 1:4 mixed with water proofing compound to top and sides and rendering 5 mm thick to soffits in cement mortar 1:3 including necessary form work, reinforcement duly welded if required including demolition of broken/loose PCC or taking down old plaster at any storey of building complete all as specified and as directed. (Note: Rate shall be included for necessary scaffolding and safety arrangement)
M & L for preparing newly plastered walls surfaces and applying two coats of cement base paint complete all as specified and directed.
M&L for two coat of cement base paint on old decorated surfaces of walls including preparation of surfaces complete all as specified and directed.
M&L for one coat of cement base paint on old decorated surfaces of walls including preparation of surfaces complete all as specified and directed.
Material & Labour for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre / 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
M&L complete removal of existing treatment of old decorated wall surfaces and including applying two coats of exterior weather coat paint over a coat of primer complete all as specified and directed. Note :- Rate shall be included for necessary scaffolding and safety arrangement.
Material & Labour for applying one coat of weather coat acrylic exterior paint on old treated surfaces of wall / floor including preparation of surfaces complete all as specified and directed. Note:- Rate shall be included for necessary scaffolding and safety arrangement.
M & L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper over a coat of primer and over a thin layer of wall care putty to obtain smooth finish complete all as specified and directed.
M&L complete removal of existing treatment of old decorated wall surfaces and including applying two coats of oil emulsion distemper over a coat of primer and over a thin layer of wall care putty to obtain smooth finish complete all as specified and directed.
M&L for preparation of old decorated wall surfaces and including applying one coats of oil emulsion distemper complete all as specified and directed.
M&L for preparing newly plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
M&L for preparing old plastered surfaces of ceiling and applying one coats of white wash complete all as specified and directed.
M & L for preparation of newly decorated plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of primer and over a thin layer of wall care putty to obtain smooth finish complete all as specified and directed.
M & L for preparation of old decorated plastered surfaces of ceiling and applying one coats of oil bound distemper complete all as specified and directed.
M&L preparation of old decorated wooden surfaces of any description, not otherwise described over 10 cm width or girth and including applying one coats of synthetic enamel paint complete all as specified and directed.
M&L preparation of old decorated steel surfaces of any description, not otherwise described over 10 cm width or girth and including applying one coats of synthetic enamel paint complete all as specified and directed.
Excavation in post holes (or similar holes) each not exceeding 0.5 cum, getting out, returning filling in and ramming earth in layers not exceeding 25 cm thick, watering and removing surplus soil to a distance not exceeding 50m and making good in soft/loose soil complete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete in any position not otherwise specifically provided for complete all as specified and directed.
S & F Mild steel work in wind ties, including securing bolts and posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
S & F of mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other or screwed both ends, each screwed ends to be fitted with washer and one hexagonal or square nut, exc. 10 cm and not exc. 15 cm long and 11 to 15 mm dia of shank complete all as specified and directed.
Supply only chain link MS galvanized fencing, for fixing to fencing post with nut and bolt and flat iron complete all as specified and directed.
Fixing only in repairs chain link fencing including line wires, any mesh, size and type of standards, rails, straining bolts, etc, and including provision of binding wire complete all as specified and directed.
S & F Galvanized, 2 strand, steel barbed wire 2.24 mm dia., barbed with 2 mm dia., barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
M&L mild steel round bars 10 mm dia and over, cut to length, bent to shape required, including hooking ends for securing chain link fencing, conforming to IS Fe 410-W(Gde.E-250), quality-A, complete all as specified and directed.
M&L preparation of new steel surfaces of any description, not otherwise described over 10 cm width or girth and including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down of LT Cable XLPE insulated UG cable of sizes 10 Sqmm to 150 Sqmm size complete all as specified and directed. Note :- Excavation, returning filling, removing paid seperately under relevent item.
Supply, laying testing and commissioning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (Heavy duty) LT cable with stranded aluminium conductor 1100 votls grade of size 10 sqmm 4 core, complete all as specified and directed.
Supply, laying testing and commissioning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (Heavy duty) LT cable with stranded aluminium conductor 1100 votls grade of size 16 sqmm 4 core, complete all as specified and directed.
Supply, laying testing and commissioning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (Heavy duty) LT cable with stranded aluminium conductor 1100 votls grade of size 25 sqmm 4 core, complete all as specified and directed.
Supply, laying testing and commissioning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (Heavy duty) LT cable with stranded aluminium conductor 1100 votls grade of size 35 sqmm 3.5 core, complete all as specified and directed.
Supply, laying testing and commissioning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (Heavy duty) LT cable with stranded aluminium conductor 1100 votls grade of size 50 sqmm 3.5 core, complete all as specified and directed.
Supply, laying testing and commissioning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (Heavy duty) LT cable with stranded aluminium conductor 1100 votls grade of size 70 sqmm 3.5 core, complete all as specified and directed.
Supply, laying testing and commissioning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (Heavy duty) LT cable with stranded aluminium conductor 1100 votls grade of size 95 sqmm 3.5 core, complete all as specified and directed.
Supply, laying testing and commissioning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (Heavy duty) LT cable with stranded aluminium conductor 1100 votls grade of size 120 sqmm 3.5 core, complete all as specified and directed.
Supply, laying testing and commissioning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (Heavy duty) LT cable with stranded aluminium conductor 1100 votls grade of size 150 sqmm 3.5 core, complete all as specified and directed.
Supply, laying testing and commissioning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (Heavy duty) LT cable with stranded aluminium conductor 1100 votls grade of size 240 sqmm 3.5 core, complete all as specified and directed.
Supply, laying testing and commissioning of cable XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric power cables (Heavy duty) LT cable with stranded aluminium conductor 1100 votls grade of size 400 sqmm 3.5 core, complete all as specified and directed.
Re-routing / re-laying of servicible LT UG cable in trenches wih necessary connection and disconnection for redistrubtion of load complete in all respects as specified and directed. Note :- Excavation, returning filling, removing sand, bricks will be measured and paid seperately under relevent items.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches exc. 1.50 m wide and exc. 1.5 m in depth but not exc. 3.00 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc. 10 Sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
M&L Sand coushioning to UG cables (8cm deep before of cables and 15 cm over the cable) including spreading, levelling, well ramming in layers complete all as speified and directed. Note :- Punned thickness of 18cm only will be considered for payment purpose.
M & L for brick work with sub class ‘B’ old size for cable protection laid flat acrossthe cable in trenches complete all as specified and directed.
S&F in repairs GI tubing light grade 40mm dia for protection pipe of cable on pole, under crossing or across drain, along electric pole or floor / wall complete including taking out if required all as specified and directed.
S&F in repairs GI tubing light grade 80mm dia for protection pipe of cable on pole, under crossing or across drain, along electric pole or floor / wall complete including taking out if required all as specified and directed.
Boring / Drilling (horizontally) manually upto 2m depth in soil below existing road suitable for passing GI tubing of 40 to 80mm bore and getting out and disposal of soil to a dist n.exc 50 meter complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation of poles including necessary form work, finishing the surface even and smooth without using ectra cement complete all as specified and directed.
M&L PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation of poles including necessary form work, finishing the surface even and smooth without using ectra cement complete all as specified and directed.
M&L PCC 1:2:4 type B-2 (using 20 mm graded crushed stone aggregate) as in coping / stay of poles including necessary form work, finishing the surface even and smooth without using ectra cement complete all as specified and directed.
M&L preparation of 9 m long old steel poles with connected cross arms, cable protection pipes, clamps, street light brackets etc, and including applying one coat of aluminium paint on complete height of the pole and including applying one coat of synthetic enamel paint upto 0.80 m height from the top of coping with muilti colour strips as per existing colour code complete all as specified and directed.
S&F in repairs 6 KW, three phase, automatic street light control panel with and including digital timer switch with astronomical function for automatic switching on / off street light according to the rising /setting of the sub with combination function for creating switching programs in which lights will be switched according to astronomical time or fixed preset time through programmable 24 hour switch, 32A, TP power contactor, 40A SPN MCB, wall / floor mountable, IP 54 (dust and vermin proof) enclosure made out of CRCA sheet duly powder coated, conforming to IS/IEC 60954-4-1, in-built- short circuit protection, locking arrangement with padlock and panel lock complete all as specified and directed.
Supply,installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted floor mounted, LT 415 V AC, 50 HZ, 3-phase 4 wire, AL Busbar chamber and PVC sheathed rating 250 Amps with color coding mounted on DMC insulator, confirming to protection class IP-54 weather and vermin proof. Panel will compliance IEC 61439, Mechanical Impact IK10. Double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet for outer portionand 2.0 mm CRCA sheet for inner portion, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.90m long, duly fabricated and having front hingled opening, rubber lining locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted internally and externally with powder coating (RAL -7032) suitable for 500 volts, 50 Hz, 3 phase 4 wire system, internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in including taking down old unsv one complete all as specified and directed.
INCOMING:- (a) MCCB 4 pole 415 volts 25 KA breaking capacity rating 100 Amps Ics=100% Icu, adjustable overload and adjustable short circuit setting, thermal magnetic type along with spreader terminals including fixing accessories - 01 No BUSBAR:- (b) Aluminium busbar suitable for 250 Amp including insulator with nuts & bolts - 04 Nos OUTGOING:- (c) MCCB 4 pole 415 volts 16 KA breaking capacity rating 63 Amps Ics=100% Icu, adjustable overload and adjustable short circuit setting, thermal magnetic type along with spreader terminals including fixing accessories - 01 No (d) Lexic indicator lamp with holder = 03 nos
M&L PVC Insulated Weather proof multicore FRLS PVC sheathed multistranded cables with bright annealed copper conductor of size 1.5 sqmm 3 core for connection of light to pole box and taking down the old u/s one completed all as specified and directed.
Supply,installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted floor mounted, LT 415 V AC, 50 HZ, 3-phase 4 wire, AL Busbar chamber and PVC sheathed rating 400 Amps with color coding mounted on DMC insulator, confirming to protection class IP-54 weather and vermin proof. Panel will compliance IEC 61439, Mechanical Impact IK10. Double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet for outer portionand 2.0 mm CRCA sheet for inner portion, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.90m long, duly fabricated and having front hingled opening, rubber lining locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted internally and externally with powder coating (RAL -7032) suitable for 500 volts, 50 Hz, 3 phase 4 wire system, internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in including taking down old unsv one complete all as specified and directed.
Supply,installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted floor mounted, LT 415 V AC, 50 HZ, 3-phase 4 wire, AL Busbar chamber and PVC sheathed rating 250 Amps with color coding mounted on DMC insulator, confirming to protection class IP-54 weather and vermin proof. Panel will compliance IEC 61439, Mechanical Impact IK10. Double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet for outer portionand 2.0 mm CRCA sheet for inner portion, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.90m long, duly fabricated and having front hingled opening, rubber lining locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted internally and externally with powder coating (RAL -7032) suitable for 500 volts, 50 Hz, 3 phase 4 wire system, internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in including taking down old unsv one complete all as specified and directed.
Supply,installing, testing and commissioning out door type LT feeder piller box of suitable size, padestal mounted floor mounted, LT 415 V AC, 50 HZ, 3-phase 4 wire, AL Busbar chamber and PVC sheathed rating 250 Amps with color coding mounted on DMC insulator, confirming to protection class IP-54 weather and vermin proof. Panel will compliance IEC 61439, Mechanical Impact IK10. Double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet for outer portionand 2.0 mm CRCA sheet for inner portion, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.90m long, duly fabricated and having front hingled opening, rubber lining locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted internally and externally with powder coating (RAL -7032) suitable for 500 volts, 50 Hz, 3 phase 4 wire system, internal wiring with single copper conductor cable/PVC insulated tinned copper strip of suitable size for incoming to busbar and busbar to MCCBs/MCBs, fine wiring with single core copper conductor cable for instruments/indicating lamps and comprising with and including following accessories and mounted on PCC Plat form made out of PCC 1:3:6, 100 mm thick, 1 Mtr all round the panel board complete with the following items housed in including taking down old unsv one complete all as specified and directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft / loose soil complete all as specified and directed.
M & L for Hardcore of gauge not exc. 63 mm, deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface using broken stone or broken boulders complete all as specified and directed.
M&L 75 mm thick, PCC 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub floor, sub base of floor, etc complete all as specified and directed.
M&L cement concrete chequered tiles 300 x 300 x 25 mm thick as in floors, set and jointed over and including 15 mm thick screed bed in CM 1:4 and pointed in grey cement and pigments to match the colour of tile complete all as specified and directed.
M&L providing PCC 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, benching, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating and including necessary formwork complete all as specified and directed.
M&L in repairs to existing LT panel / bus bar chamber / feeder pillar box of any size by excavation of all loops and removing damaged UG cable, connecting new thimbles / lugs / cable glands and fixing of new neoprene rubber gasket to make it completely dust and vermin proof, fixing of new locking arragement and replacement of LT panel wiring with appropriate size of copper conductor, repairing of rusted parts of panel frame and shutter with necessary welding works including preparation and applying one coat of synthetic enamel paint on both internal and external surface of panel, PCC (1:3:6) type C2 (using 40mm crushed stone aggregate) work in foundation complete all as specified and directed. Note:-The unit rate quoted is deemed to include cost of earth work, PCC in foundation, new thimbles / lugs / cable glands, neoprene rubber gaskets, locking arrangement, Wiring, welding works, painting.
M&L for ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 630 Amps complete all as specified and directed.
M&L for ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amps complete all as specified and directed.
Supply, installation, testing and commissioning of MCCB 160 A with extended terminals both side , 36KA 4 pole Ics =100%Icu with thermal magnetic protection unit of suitable size have to be fitted in existing LT Panel complete including old unsv one all as specified and as directed.
Supply, installation, testing and commissioning of MCCB 250 A with extended terminals both side , 36KA 4 pole Ics =100%Icu with thermal magnetic protection unit of suitable size have to be fitted in existing LT Panel complete including old unsv one all as specified and as directed.
Supply, installation, testing and commissioning of MCCB 400 A with extended terminals both side , 36KA 4 pole Ics =100%Icu with thermal magnetic protection unit of suitable size have to be fitted in existing LT Panel complete including old unsv one all as specified and as directed.
S&F in repair LED Street light 60 watt made up of pressure die cast aluminium housing environment friendly with high efficiency LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. System Lumen Efficasy ≥120 Lm/W, 10 kV Surge Voltage Protection, Operating Voltage range 140 V - 270 V, Make of LED - Cree/Nichia/Osram/Agilent/Lumileds etc and including necessary fixing arrangement to fix the fitting with pole complete all as specified and directed. Note :- 1.Contractor have to submit LM 79 and LM 80 report from NABL accredited Lab,Test Certificate and other relevant documents as directed by Engr-inCharge before approval of product. 2. Cost of taking down old unsv fittings is deemed to be included in unit quoted rates.
S&F in repair LED Street light 90 watt made up of pressure die cast aluminium housing environment friendly with high efficiency LED as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07. System Lumen Efficasy ≥120 Lm/W, 10 kV Surge Voltage Protection, Operating Voltage range 140 V - 270 V Make of LED - Cree/Nichia/Osram/Agilent/Lumileds and including necessary fixing arrangement to fix the fitting with pole complete all as specified and directed. Note :- 1.Contractor have to submit LM 79 and LM 80 report from NABL accredited Lab,Test Certificate and other relevant documents as directed by Engr-inCharge before approval of product. 2. Cost of taking down old unsv fittings is deemed to be included in unit quoted rates.
S&F Bracket suitable for street light made out of GI pipe light grade of 25 mm bore & 0.75 mtr length (minimum), bend to shape including 2 pairs of MS flat iron clamps made out of 40 x 5 mm MS flat, nuts, bolts & washers etc, & painting the bracket with two coat of aluminium paint over a coat of red oxide primer including taking down complete all as specified and directed.
S&F Bracket suitable for street light made out of GI pipe light gradeof 40 mm bore & 1.2 mtr length (minimum), bend to shape including 2 pairs of MS flat iron clamps made out of 40 x 5 mm MS flat, nuts, bolts & washers etc, & painting the bracket with two coat of aluminium paint over a coat of red oxide primer including taking down complete all as specified and directed.
S&F in repair factory made (CPRI approved) weather proof, dust & vermin proof street light junction box of size 250 (L) x 250 (B) x 150 (D) mm (minimum dimensions) made up of 3.15 mm thick CRCA sheet, powder coated after preparation of surfaces comprising of 04 Nos aluminium bus-bar of size 20 x 4 mm mounted on suitable sized spacer insulators with provn of 01 No MCB SP 6 Amps, 10 KA breaking capacity, "C" curve & two openings at the bottom & one opening at the top with cable glands & fixing with the help of suitable sized MS clamps to steel poles including testing & taking down oold unsv one complete all as specified & as directed.
S&F in repair Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium LED Flood Light 100 watt, Tempered protective toughened glass with IP66, and impact resistant with IK07, System Lumen Efficasy ≥120 Lm/W, 10 kV Surge Voltage Protection, , Operating Voltage range 140 V - 270 V including necessary fixing arrangement to fix the fitting with pole and taking down old unsv one complete all as specified and directed.
S&F in repair Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium LED Flood Light 400 watt, Tempered protective toughened glass with IP66, and impact resistant with IK07, System Lumen Efficasy ≥120/135 Lm/W, 10 kV Surge Voltage Protection, , Operating Voltage range 140 V - 270 V including necessary fixing arrangement to fix the fitting with pole and taking down old unsv one complete all as specified and directed.
S&F in repair Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium LED Flood Light 500 watt, Tempered protective toughened glass with IP66, and impact resistant with IK07, System Lumen Efficasy ≥120/135 Lm/W, 10 kV Surge Voltage Protection, , Operating Voltage range 140 V - 270 V including necessary fixing arrangement to fix the fitting with pole and taking down old unsv one complete all as specified and directed.
S&F in replacement of RCC pole with Steel Tubular Poles complete with and including cast iron base plate , finial taper plug, bolts , nuts & screws, type 410 SP-31(9 Mtr long), also including painting to the external exposed surfaces with 2 coats of aluminium paint over 1 coat of red oxide primer and with 2 coats of black bituminous paint over 1 coat of red oxide primer to the external exposed surfaces of steel poles embedded in the ground / concrete after preparation of the surfaces, numbering to the poles, including taking down of old damaged RCC pole complete all as specified and as directed, Note :- Excavation & Earth Work, concrete for foundation and coping shall only be measured and paid for separately.
M&L Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground in vertical position (earth pit not less than 2.5 m deep below the normal ground level) with top edge of the earth plate not less than 1.5m below normal ground level, connected to galvanised earth lead of GI strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel, all as shown in electrical plate No.3 connected to earthing test point and including dismantling complete all as specified and directed. Note :- The unit rate shall also include for earth work in any type of soil, PCC 1:3:6 type C1 chamber, RCC 1:1.5:3 type A1 cover slab, 450 x 450 x 50 mm thick reinforced with 8 mm dia TMT bar @140 mm C/C both ways, 10mm dia plain bar lifting handle embedded in cover slab, 20 mm bore medium grade GI watering pipe, 40 mm bore GI medium grade earth lead protection pipe, funnel, wire mesh, copper lugs, charcoal and common salt in alternate layer etc.
M &L of Earthing with galvanised steel earth plate electrode 600 mm x 600 mm x 6 mm thick, buried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below ground level connected using galvanised iron earth lead wire 4 Sq mm as earthing electrode by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe (medium grade) and other end connected to earthing test point as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth up to a distance not exceeding 50 Mtr etc all as shown on electrical plate No. 5 of MES Schedule Part-I complete including testing on completion. On testing after completion if the desired earth resistance is not obtained the earthing will be made again by the contractor at no additional cost and including dimantling complete all as specified and directed.
S&F in replacement GI strip 32 x 6 mm with necessary nut and bolt etc for connection with existing Earting pit and electrical equipment including taking down old unsv one complete all as specified and directed.
S&F in replacement earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed.
S&F of mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe - 290 Gde E - 165 complete all as specified and directed.
S&F rolled mild steel in plates, gusset plate (plain or chequered) channels square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410W (Gde-E-250) quality-A complete all as specified and directed.
M&L PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation, sub base, hardstanding etc complete all as specified and directed.
S & F of steel work as in tubular trusses including special shaped washers etc. complete using ERW or induction butt welded tubes including gusset plate including erection of vertical supports for holding purlins, raftors etc baseplates , nuts & bolts etc conforming to IS – 1161 – 1979 grade St – 240 complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50 mm TCT (total coated thickness) of any colour having tensile strength of 550 Mpa as in roof covering cladding to wall etc, fixed with self tapping screws complete all as specified and directed.
M&L 60 mm thick machine pressed precast concrete interlocking coloured paver block of any shape and size confirming to IS 15658-2006, M-35 grade, set with grey cement and pigment, laid over and including 20 mm thick screed bed in CM 1:6 and including taking down complete all as specified and directed.
M&L for roof treatment in order of precedence as given below complete all as specified and as directed:- (i) Taking out of existing water proofing treatment and including padding, cleaning the surface using wire brush, brooming down and washing down with water to remove dust etc, and brushing with neat cement slurry @ 3.00 kg of cement per Sqm. (ii) 15 mm thick screed bed in CM 1:4 on surface. (iii) Cleaning of plastered surface and applying one coat of bituminous primer @ 0.40 Ltr / Sqm. (Contd...)
(iv) Supply and laying 3 mm (Minimum) thick APP based polymeric membrane of approved manufacturer with weight not less than 3.60 Kg per Sqm, reinforced with non-woven polyester fabric weight not less than 150 gms per Sqm. Polymeric membrane shall be taken to a height of 30 cm (minimum) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (v) Applying one coat of water proofing paint with aluminium finish over APP as per manufacturer's instruction. Note :- (a) Bituminous primer shall be "ShaliTex Primer" manufactured by M/s STP Ltd or equivalent in M/s Sika India Pvt Ltd or M/s Fosroc Chemicals or M/s Hindcon chemicals limited or M/s IWL India Limited (b) Laying APP based polymeric membrane shall be done by torch on method as per manufactures instructions. (c) A minimum overlap of 100 mm and 75 mm should be made at the end and sides of the polymeric membrane respectively and all overlaps and joints shall be sealed as per manufacturers instruction. (d) APP based polymeric membrane shall be manufactured by M/s STP Ltd or Berger Paints or M/s Sika India Pvt Ltd or M/s Fosroc Chemicals or M/s Hindcon chemicals limited or M/s IWL India Limited (e) Water proofing paint shall be by M/s STP Ltd or Berger Paints or M/s Sika India Pvt Ltd or M/s Fosroc Chemicals or M/s Hindcon chemicals limited or M/s IWL India Limited
Supply only liquid water proofing compound ISI mark complete all as specified and directed.
KARMIBRINDA
PS ENTERPRISE
MS ORIENT ENGINEERING WORKS
R K UDYOG
M/s B. K. Ghosh and Co.
M/S GLORIOUS CONSTRUCTION
SHRI N.DAS
ASHOK MUKHERJEE
M/S ASHRAFI CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .