Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 CrAccepted-AOC 135 CHAKRANA TIWARI CHAKA NAINI PRAYAGRAJ 211008 UTTAR PRADESH | PRAYAGRAJ | UTTAR PRADESH | 211008 | ₹4.2 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹4.3 Cr+₹15.8 L (3.78%)Rejected-Finance | ₹4.3 Cr+₹15.8 L (3.78%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹4.4 Cr+₹24.7 L (5.92%)Rejected-Finance | ₹4.4 Cr+₹24.7 L (5.92%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹4.6 Cr+₹42.7 L (10.2%)Rejected-Finance | ₹4.6 Cr+₹42.7 L (10.2%) | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹4.7 Cr+₹50.9 L (12.2%)Rejected-Finance 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | ₹4.7 Cr+₹50.9 L (12.2%) | L5 | Rejected-Finance Other than lowest |
Tender Value
₹4.2 Cr
EMD Value
₹5.0 L
Closing Date
27 Sept 2023, 6:00 pmClosed
Chief Engineer Udhampur Zone
HQ Chief Engineer Udhampur Zone PIN-900386 C/O 56 APO
RE-CONSTRUCTION OF SECURITY WALL WITH ALLIED INFRA FOR CERTAIN UNIT UNDER GE (S) UDHAMPUR
2023_MES_615068_1
87901-A/E8
Open Tender
Civil Works
Lump-sum
455 days
Udhampur
As per NIT
8 documents required · 8 mandatory
₹2,000
GE (S) Udhampur
₹5.0 L
21 Nov 2023
22 Aug 2023
29 Sept 2023
22 Aug 2023
27 Sept 2023
22 Sept 2023
Amount
Sch 'A' Part - I (Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
Construction of RCC Guard Post with Rest Room for six person with toilet facility complete all as shown on drawings and as specified.
Construction of Elevated guard Post alongwith stair case complete all as shown on drawings and as specified.
Total Amount of Sch 'A' Part - II (Site Clearance)
Total Amount of Sch 'A' Part - III (Internal Water Supply)
Total Amount of Sch 'A' Part - IV (Internal Electric Supply)
Total Amount of Sch 'A' Part - V (Plumbing work)
Total Amount of Sch 'A' Part - VI (Protective Work )
Total Amount of Sch 'A' -VII (Area Drainage Work)
Total Amount of Sch 'A' Part - VIII (Sewage Disposal work)
Total Amount of Sch 'A' -IX (Path Work)
Total Amount of Sch 'A' -X (Security wall,RCC wall,, steel Gate,Fencing work)
Total Amount of Sch 'A' Part -XI ( External Water Supply Works)
Total Amount of Sch 'A' Part -XII (External Electrification Works)
Total Amount of Sch 'A' Part -XIII (Demolition Work)
Sch 'A' Part - XIV (Misc Items work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
Concertina coil 600 mm dia, 56 loops, 2.5 mm core wire, heavy galvanised (wire 275 GSM & Strip 200 GSM) , tensile strength of wire 1400 - 1500 N/Sqmm, weight 6-8 Kg/coil, stretchable length 6m to 8 m including securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc complete, all as specified and as directed.Make : M/s Global Engg/ M/S Special Steels Ltd/ M/s Super Fence.
Cutting existing water line connection 50/40 mm dia pipe and making suitable size for joining 40/25 mm dia pipe including welding, bending and necessary fitting etc. complete all as specified and directed by Engr-in-Charge.
LED street light (with LDR Sensor) fitting 45 Watt energy saving long life LED street light made up of pressure die cast aluminium housing with toughened glass having IP 66 protection( 110 Lm/ W) including brackets made out of 40mm bore GI pipe medium grade 1.5m long bend to shape and including suitable MS clamps made out of 40x6mm MS flat iron necessary bolts ,nuts, washers etc complete all as specified and directed.
LED 35 Watt Cone round post top lantern clear/ milky diffuser, spum cover, die cast pole mounting, IP 65, Module with LED (100 Lm/ W) ,complete all as specified and directed.
LT junction box for street light, sheet moulding compound (SMC) type with hinged type door and locking arrangement, off white colour, of size 250 x 150 x 100mm (internal) including three phase bus bar and 01 No MCB,SP 06 Amps for street light control mounted on pole with the provision of cable entry and exit ,complete all as specified and directed.
Earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, Jall: pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board and testing on completion complete all as specified and directed.
Wall mounted fan 300mm sweep, non spectrum grey connecting up with three core flexible copper conductor cable of suitable size of ceiling rose , Complete all as specified and directed.
LED street light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, including GI bracket light grade 25 mm dia, 1.2 m long bend in shape fixed on wall having an angle 120 degree, fixed with and including two nos 25x4 mm size flat mild steel clamp made to shape and suitable size nuts, bolts and washers etc including taking down of existing light fitting complete all as specified and directed.
LED flood light 120 watt 230 VAC of high pressure die-cast aluminium with front glass casing IP66 protection (110 Lm/W) outdoor type with thermal management in multiple optics and equipped, with impact and corrosion resistant complete with driver all as specified and directed by Engr-in-Charge.
Construction of septic tank for 10 users (Brick construction) complete all as shown on drgs and as specified.
Construction of soakage well (Brick construction) 1.20m dia and 1.50m deep (Internal dimensions) below inlet pipe level (depth from inlet pipe to ground level 45cm), complete all as specified and shown on drawings.
Deduction to be made from BOQ for Sch 'A' Part - XV (Schedule of credit) Amount of Rs. 6,89,535.00 during AOC. Note: Tenderers shall not quote for this schedule.
M/S Inderjit Sharma and Co.
M/S VED PARKASH GUPTA
Onkar Nath Bhalla And Sons Contractor Pvt. Ltd.
R K BUILDERS
R R CONSTRUCTION
M/S KAPIL KUMAR KHATTAR
V K Sales and Construction Co
Chandra Construction
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .