Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.5 LAccepted-AOC GROUND 1 9 670 65 ADIKMET SRT COLONY VIDYANAGAR HYDERABAD 500044 | HYDERABAD | TELANGANA | 500044 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹21 L+₹46,339.18 (2.26%)Rejected-Finance 3 6 753 A GENERAL ELECTRICALS REFRIGERATION 3 6 753 A HIMAYATHNAGAR ST NO 14 40 HYDERABAD TELANGANA 500029 | HYDERABAD | TELANGANA | 500029 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹21.6 L+₹1.1 L (5.28%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | Rejected-Technical 189 TEACHEARS COLONY THAKUR PLOT TAJBAG NAGPUR 440024 | NAGPUR | MAHARASHTRA | 440024 | - | Rejected-Technical Not Meeting NIT creteria |
Tender Value
₹26.7 L
EMD Value
₹53,476
Closing Date
23 Dec 2019, 6:00 pmClosed
AGM(E-E), AAI, Begumpet Aiprort, Hyd - 500016
O/o AGM(E-E), AAI, Begumpet Aiprort, Hyd - 500016
Miscellaneous works Sub head Replacement of ACs, Geysers and Providing additional AC units to various offices at Begumpet Airport, Hyderabad
2019_AAI_37852_1
AAI/HYD/ENGG(E)/ENIT-08/2019
Open Tender
Electrical Works
Works
90 days
O/o AGM(E-E), AAI, Begumpet Aiprort, Hyd
Please refer Tender documents.
11 documents required · 11 mandatory
₹1,180
Airports Authority of India
₹53,476
4 Sept 2020
13 Dec 2019
30 Dec 2019
14 Dec 2019
23 Dec 2019
14 Dec 2019
14 Dec 2019 - 20 Dec 2019
Amount
Supplying, Installation, Testing and Commissioning of minimum following capacity and type AC system having remote Operation and copper condensor coil and Rotary/scroll compressor including providing and fixing of Iron angle i/c minor civil work for ODU as per manufacturer standard along with the supply and laying of standard length of copper refregerant liquid and suction pipe and suitable size Cu conductor multi core cable as per manufacturer recommendation by drilling necessary hole on the concrete wall (if required) and making good the damages etc. with all necessary standard protections/accessories and features as per OEM etc. complete as required .
5-star rated minimum 1.5 TR Split type Inverter AC suitable for operation on 230 +/- 10% V, 50 Hz, 1-Phase AC Supply
5-star rated minimum 2.0 TR Split type Inverter AC suitable for operation on 230 +/- 10% V, 50 Hz, 1-Phase AC Supply
Minimum 1.9 TR capacity Cassette type AC suitable for operation on 230 +/- 10% V, 50 Hz, 1-Phase AC Supply
Minium 2.7 TR Cassette type AC suitable for operation on 415 +/- 10% V, 50 Hz, 1-Phase AC Supply
Minimum 3.8 TR Tower type suitable for operation on 415 +/- 10% V, 50 Hz, 1-Phase AC Supply
Supply and Laying of additional length of suitable size refregerant Copper piping along with insulation and suitable size FR PVC insulated multicore Cu conductor cable as per manufacturer recommendation as required for connection between indoor and outdoor units of above wall mounted Split AC's of various capacity etc. complete as required.
Supply and Laying of additional length of suitable size refregerant Copper piping along with insulation and suitable size FR PVC insulated multicore Cu conductor cable as per manufacturer recommendation as required for connection between indoor and outdoor units of above cassette AC's of various capacity etc. complete as required.
Supply and Laying of additional length of suitable size refregerant Copper piping along with insulation and suitable size FR PVC insulated multicore Cu conductor cable as per manufacturer recommendation as required for connection between indoor and outdoor units of above floor mounted AC's of various capacity etc. complete as required.
Supply and Laying of additional length of suitable size hard PVC pipe for draining out the water etc. complete as required.
SITC of Water Cooler with inbuilt RO based 7 stage water purification system with 80 Ltrs storage capacity and 50 LPH purification capacity having two faucets , gas as refregerant and compressor complete with all accessories and standard manufacturer design suitable for operation on 230V+/-10%V, 50 Hz, 1-Phase AC supply etc. complete as required.
SITC of 5-Star rated wall mountable Water Heater system with inbuilt 10 Litre storage capacity complete with all accessories and features as per manufacturer standard suitable for operation on 230V+/-10%V, 50 Hz, 1-Phase AC supply etc. complete as required.
Supplying and fixing 20 A, 415 V, SPN MCB protected socket in sheet steel enclosure, on surface or in recess etc. complete with connections, testing and commissioning etc. as required.
Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 6-32 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, complete with connections, testing and commissioning etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
General Electricals and Refrigeration
KALKI ELECTRICALS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .