AE/KCESD-I
Khadya_Bhawan_11A_Mirza_Ghalib_Street_Block_B_6th_Floor_Kokata_700087
SITC of 2 Nos Split type AC Machine in the Account Section Room No. 32 located at the 1st Floor of Intelligence Branch, Main Building, Lord Sinha Road..
2026_WBPWD_5019035_1
WBPWD/AE/13/PR/T/KCESD/I of 2026-27(3rd CALL)
Open Tender
Electrical Work/ Equipment
Percentage
7 days
I.B, 13 Lord Sinha Road
Please refer Tender documents.
4 documents required · 4 mandatory
₹3,540
18 Aug 2026
18 Aug 2026
3 Sept 2026
18 Aug 2026
1 Sept 2026
24 Aug 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply & Delivery of split type AC machines having Cooling Capacity range (6.1 minimumKW), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.81 to 3.88), air-flow range CFM (800minimum) both condenser and cooling coils made of copper tube connecting chord with plug top confirming to ISI 1391 (Part-1 & Part-II) with all amendments. (Make: O-General / Mitsubishi Electric / Mitsubishi Heavy / Daikin) | 2 | Nos | 62,308 | ₹1,24,616 |
| 2 | Installation, Testing & Commissioning of Split type Air Conditioning Systems with all necessary accessiores for Indoor & Outdoor Units as per direction of EIC. | 2 | sets | 1,961 | ₹3,922 |
| 3SITC including vaccumiazation and Nitrogen of testing of following nominal size of soft / hard drawn copper refrigerant piping for Concealed Split type AC, complete with fttings, with adjustable ring type hanger supports, jointing / brazing including acccssories, insulated with XLPE class-0 tubular insulation / with Class-0 closed cell elastonctric nitrile rubber tubular sleeves sections of specified thickness as given below for suction and liquid lines all accessorics as per specification etc. as required. | |||||
| 3.01 | (i) 5/8"(15.88 mm) dia soft drawn Cu. Pipes (As per standard BS864 or ANSIB 16.22) for Gas line incl. 9mm thick nitrile rubber insulation. | 25 | Mts | 604 | ₹15,100 |
| 3.02 | (ii) 1/4"(6.35 mm) dia soft drawn Cu. Pipes (As per standard BS864 or ANSIB 16.22) for Liquid line incl. 9 mm thick insulation | 25 | Mts | 266 | ₹6,650 |
| 3.03 | Supply & Laying 19 mm dia flexible drain Water piping work out of PVC incl. fitting with accessories. | 25 | Mts | 74 | ₹1,850 |
| 4 | Supply and laying of 1.1KV grade 3 Core 2.5 Sqmm. copper armoured round cable from IDU to ODU for above mentioned AC machines. (Make: Polycab / Havells / Gloster / Finolex) | 30 | Mts | 122 | ₹3,660 |
| 5 | S & F 2(+1) Module IP-65 rated waterproof cabinet on wall including necessary accessories with S&F 240V, 32A DP MCB Isolator incl. necy. connections, socketing etc. as per direction of EIC. (Make: Legrand) | 2 | sets | 2,437 | ₹4,874 |
| 6 | S & F 240V, OLP-3+, 27A Digital A.C. machine Starter as required including S&F of 4 module GI box including necessary connections (Voltcheck, Amp Check & Timecheck & 3 digit display). (Make: Electron) | 2 | sets | 2,125 | ₹4,250 |
| 7 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed (2 x 4 sqmm + 1 x 2.5 sqmm) copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. | 50 | mts | 178 | ₹8,900 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.48 MB
BOQ_5090737.xls
BOQ • 0.32 MB
2911.pdf
Tender Documents • 0.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].