Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LRejected-Finance | L1 | Rejected-Finance Overall rates are on higher side | |
| 2 | L2₹26.2 L+₹53,228 (2.08%)Rejected-Finance | L2 | Rejected-Finance Overall rates are on higher side | |
| 3 | L3₹26.2 L+₹56,771 (2.21%)Rejected-Finance | L3 | Rejected-Finance Overall rates are on higher side | |
| 4 | L4₹26.4 L+₹76,207 (2.97%)Rejected-Finance 131 SANGAM NAGAR OPP NATIONAL SCHOOL SANGHVI PUNE 411027 | PUNE | MAHARASHTRA | 411027 | L4 | Rejected-Finance Overall rates are on higher side | |
| 5 | L5₹26.8 L+₹1.1 L (4.34%)Rejected-Finance | L5 | Rejected-Finance Overall rates are on higher side |
| Sl No | Description | Qty | Unit | Leo Enterprises L4 | K.K.Enterprises L3 | GRID SYSTEMS L2 | Tejas Enterprises L6 | Sneha Aircool L5 | SUNIT TRADING CORPORATION L1 | KSONS L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | M&L for repair / maintenance of internal electrification through attending day to day complaints for No lights, switches, sockets, fan regulators, lamp holders, call bells, cover plates, hylum sheets, switch boards, ceiling & exhaust fans, MCBs, light fittings of any type and rectifying the defects as required in due time complete all as directed by Engineer-in Charge.
Note: (i) The rate quoted shall be deemed to be included the cost of labour for taking down the unserviceable items & re-fixing only of new item and rectifying the defects, with and including minor spares such as insulation tap, thimbles, small pieces of copper cable, screws, washers, nut bolts & T&P etc. required and transportation of man & material to the site.
(ii) All necessary spares required such as switches, sockets, fan regulators, lamp holders, call bells, cover plates, hylum sheets, switch boards, fan condensers will be measured and paid separately as supply only in the relevant items here-in after.
(iii) Complaints regarding rewiring will be measured and paid separately under relevant items.
(iv) The contractor's representative shall report to concerned JE E/M at 0900 hrs daily (including Sunday and Holidays) to collect the list of defects and shall submit the status of rectification of defects before 1700 hrs or before leaving the site on the same day. All defects / complaints excluding rewiring shall be rectified within 48 hrs from handing over the defects/ complaints. Any discrepancies and hurdles (such as door lock, user not available, major repair required, burnt wiring etc.) in this regard shall be reported to JE E/M and Engr-in-Charge in due time. Defects not rectified or delayed deliberately, within stipulated time, if found shall be liable for penal recovery @ twice of the quoted rate of this item and multiplied by number of defects/ complaints delayed by the contractor.
(vi). (i) Attending of 10 Nos. of complaints / defects and make it functional shall be measured as one job. | 200 | Each Job | 120 ₹24,000 | 115 ₹23,000 | 105 ₹21,000 | 128 ₹25,600 | 125 ₹25,000 | 100 ₹20,000 Lowest | 140 ₹28,000 |
| 2.00 | S&F in replacement of Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 04 Sqmm nominal cross sectional area,1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable and including ISI marked PVC casing caping including fitting in wall etc and connected to common earth dolly making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed.
Note :- One meter of PVC casing caping along with two runs of 4 Sqmm wire and one run of 2.5 Sqmm earth wire shall be measured as one unit length | 250 | RM | 235 ₹58,750 | 230 ₹57,500 | 228 ₹57,000 | 243 ₹60,750 | 240 ₹60,000 | 225 ₹56,250 Lowest | 250 ₹62,500 |
| 3.00 | S&F in repairs, Metal plug and socket, 2 pin and earth plug and socket including with 20 Amps, MCB, SP concealed / surface on wall as per site requirement including all cutting holes in or through walls, making good to disturbed surfaces of walls, ceiling etc including applying two coats of white / colour washing / distempering etc as applicable to the disturbed surfaces to match the existing complete all as specified and directed.
Make - L&T / Legrand / ABB /Schenider | 5 | Each | 995 ₹4,975 | 990 ₹4,950 | 985 ₹4,925 | 1,008 ₹5,040 | 1,005 ₹5,025 | 980 ₹4,900 Lowest | 1,050 ₹5,250 |
| 4.00 | S&F in replacement MCB SPN 40 Amps, 10 KA, 230 volts, 'C' series complete all as specified and as directed. | 8 | Each | 968 ₹7,744 | 965 ₹7,720 | 955 ₹7,640 | 986 ₹7,888 | 980 ₹7,840 | 950 ₹7,600 Lowest | 990 ₹7,920 |
| 5.00 | M&L for Servicing / overhauling of split AC with chemical washing process of outdoor unit, cleaning the filter, indoor unit grill, oiling of motor including replacing of defective parts like, blower motor, condenser fan, condenser motor, relay, selector switch, thermostat, compressor, cooling coil, PCB, capacitor and making the appliances functional, complete all as directed by Engr-in-charge.
Note:- (i). Every AC shall be serviced once in contract period. (ii). All spares parts required shall be measured and paid separately.
(iii). On call services shall includes attending to any complaint any time of the contract period on receipt of verbal / written complaint from user / JE E/M / Engr-in-Charge. (iv). In case of any complaint is not made functional for whatsoever reason within the specified time limit, an amount of Rs 100.00 per such complaint per day will be recovered from the amount due to the contractor through RAR / Final Bill.
(v). Servicing / overhauling of 01 No. AC complete in all respect and make it functional shall be measured as one job. | 138 | Each Job | 520 ₹71,760 | 518 ₹71,484 | 450 ₹62,100 | 535 ₹73,830 | 530 ₹73,140 | 350 ₹48,300 Lowest | 550 ₹75,900 |
| 6.00 | S&F starting capacitor of 40 to 60 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge | 6 | Each | 55 ₹330 | 54 ₹324 | 52 ₹312 | 63 ₹378 | 60 ₹360 | 50 ₹300 Lowest | 65 ₹390 |
| 7.00 | S&F starting capacitor of 60 to 80 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge | 7 | Each | 55 ₹385 | 54 ₹378 | 52 ₹364 | 63 ₹441 | 60 ₹420 | 50 ₹350 Lowest | 65 ₹455 |
| 8.00 | S&F starting capacitor of 80 to 100 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-chargecomplete all as specified and as directed. | 9 | Each | 110 ₹990 | 108 ₹972 | 105 ₹945 | 117 ₹1,053 | 114 ₹1,026 | 100 ₹900 Lowest | 120 ₹1,080 |
| 9.00 | S&F starting capacitor of 100 to 120 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge | 5 | Each | 110 ₹550 | 108 ₹540 | 105 ₹525 | 117 ₹585 | 114 ₹570 | 100 ₹500 Lowest | 120 ₹600 |
| 10.00 | S&F running capacitor of 10/15/25 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge | 22 | Each | 260 ₹5,720 | 258 ₹5,676 | 255 ₹5,610 | 268 ₹5,896 | 265 ₹5,830 | 250 ₹5,500 Lowest | 270 ₹5,940 |
Tender Value
₹26 L
EMD Value
₹52,000
Closing Date
1 Jul 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE South Pune
NO 1 GEN BHAGAT MARG PUNE 40
8703 REPAIR AND MAINTENANCE OF SUMMER APPLIANCES AND ACS UNDER AGE EM II OF GE SOUTH PUNE
2025_MES_713382_1
8703 GE SOUTH PUNE
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE South Pune
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE SOUTH PUNE
₹52,000
Yes
12 Aug 2025
9 Jun 2025
3 Jul 2025
9 Jun 2025
1 Jul 2025
24 Jun 2025
Amount
M&L for repair / maintenance of internal electrification through attending day to day complaints for No lights, switches, sockets, fan regulators, lamp holders, call bells, cover plates, hylum sheets, switch boards, ceiling & exhaust fans, MCBs, light fittings of any type and rectifying the defects as required in due time complete all as directed by Engineer-in Charge. Note: (i) The rate quoted shall be deemed to be included the cost of labour for taking down the unserviceable items & re-fixing only of new item and rectifying the defects, with and including minor spares such as insulation tap, thimbles, small pieces of copper cable, screws, washers, nut bolts & T&P etc. required and transportation of man & material to the site. (ii) All necessary spares required such as switches, sockets, fan regulators, lamp holders, call bells, cover plates, hylum sheets, switch boards, fan condensers will be measured and paid separately as supply only in the relevant items here-in after. (iii) Complaints regarding rewiring will be measured and paid separately under relevant items. (iv) The contractor's representative shall report to concerned JE E/M at 0900 hrs daily (including Sunday and Holidays) to collect the list of defects and shall submit the status of rectification of defects before 1700 hrs or before leaving the site on the same day. All defects / complaints excluding rewiring shall be rectified within 48 hrs from handing over the defects/ complaints. Any discrepancies and hurdles (such as door lock, user not available, major repair required, burnt wiring etc.) in this regard shall be reported to JE E/M and Engr-in-Charge in due time. Defects not rectified or delayed deliberately, within stipulated time, if found shall be liable for penal recovery @ twice of the quoted rate of this item and multiplied by number of defects/ complaints delayed by the contractor. (vi). (i) Attending of 10 Nos. of complaints / defects and make it functional shall be measured as one job.
S&F in replacement of Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLS cable with stranded copper conductor of size with 04 Sqmm nominal cross sectional area,1100 Volts grade, stranded, PVC insulated, unsheathed, copper conductor FRLS- confirming to IS: 694-1990 with and including continuous earth wire of size 2.5 Sqmm nominal cross sectional area, single core, PVC insulated, copper conductor cable and including ISI marked PVC casing caping including fitting in wall etc and connected to common earth dolly making good to walls etc including two coats of white / colour washing / distempering etc to the disturbed surfaces to match the existing complete all as specified & directed. Note :- One meter of PVC casing caping along with two runs of 4 Sqmm wire and one run of 2.5 Sqmm earth wire shall be measured as one unit length
S&F in repairs, Metal plug and socket, 2 pin and earth plug and socket including with 20 Amps, MCB, SP concealed / surface on wall as per site requirement including all cutting holes in or through walls, making good to disturbed surfaces of walls, ceiling etc including applying two coats of white / colour washing / distempering etc as applicable to the disturbed surfaces to match the existing complete all as specified and directed. Make - L&T / Legrand / ABB /Schenider
S&F in replacement MCB SPN 40 Amps, 10 KA, 230 volts, 'C' series complete all as specified and as directed.
S&F starting capacitor of 40 to 60 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge
S&F starting capacitor of 60 to 80 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge
S&F starting capacitor of 80 to 100 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-chargecomplete all as specified and as directed.
S&F starting capacitor of 100 to 120 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge
S&F running capacitor of 10/15/25 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge
S&F running capacitor of 36 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge
S&F running capacitor of 45 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge
S&F running capacitor of 55-60 mfd capacity of existing make or as per sample including taking down old unserviceable capacitor, complete all as directed by Engr-in-charge
S&F fan blade (As per sample) in replacement suitable for split type AC of any capacity, complete all as directed.
S&F thermostat complete suitable for split AC, as per smple including taking down old unserviceable thermostate, complete all as directed.
S&F air filter made out of nylon wire mesh moulded in plastic, same as per old existing filter's size and shape suitable for 1.5/2 TR capacity of split type AC, complete all as directed.
S&F cooling coil assembly suitable for any Make & any model of split AC complete including taking down of old unserviceable cooling coil, complete all as directed.
S&F condenser coil assembly suitable for any Make & any model of split AC complete including taking down of old unserviceable condenser coil assembly, complete all as directed.
S&F wiring kit suitable for split AC including taking down of old unserviceable wiring kit, complete all as directed
S&F single shaft blower motor of 1/6, 1/8, 1/5 HP capacity suitable for split type AC of capacity 1.5/2 TR of any size complete as directed by Engineer-in-Charge
S&F swing motor suitable for split AC (as per sample) including taking down of old unserviceable swing motor, complete all as directed.
S&F electronic circuit plate (PCB) including necessary repairs to electronic circuit of remote operation suitable for 1.5 / 2.0 ton split type AC for any type complete all as directed.
S&F in replacement of remote with stand suitable for 1.5 / 2 ton split type AC operation for any make complete all as directed.
S&F in replacement Air break contactor relay 6.2 Amps, 415 Volts AC suitable for split type AC, complete all as directed
S&F in repairs single pole contactor of existing model and size suitable for 1.5 TR split type AC as per sample, complete all as directed.
S&F in repairs 3 pole power contactor 25 Amp, 220V AC suitable for 2 TR split type AC, as per sample, complete all as directed.
Taking down unserviceable / damage wall mounted cooling coil unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new cooling coil indoor unit of 1.5 ton capacity of existing dismantled model or equivalent as approved by Engineer-in-Charge including remote control, proper fixing on wall, connect to electrical system and connect to suction and discharge pipe line, drain water pipe line etc as directed and testing & commissioning to ensure satisfactory performance of unit after gas charging, complete all as directed.
Taking down unserviceable / damage wall mounted cooling coil unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new cooling coil indoor unit of 2 ton capacity of existing dismantled model or equivalent as approved by Engineer-in-Charge including remote control, proper fixing on wall, connect to electrical system and connect to suction and discharge pipe line, drain water pipe line etc as directed and testing & commissioning to ensure satisfactory performance of unit after gas charging, complete all as directed.
Taking down unserviceable / damaged / rusted condensor unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new condensor outdoor unit consisting of body, motor, condensor & blade suitable for 1.5 ton existing dismantled model or equivalent as approved by Engineer-in-Charge and connect to suction and discharge pipe line to compressor after re-fixing compressor of existing unit and testing & commissioning to ensure satisfactory performance of unit after gas charging, complete all as directed.
Taking down unserviceable / damaged / rusted condensor unit of split type AC complete by means of disconnecting electrical connection and suction and discharge pipe line and S&F new condensor outdoor unit consisting of body, motor, condensor & blade suitable for 2 ton existing dismantled model or equivalent as approved by Engineer-in-Charge and connect to suction and discharge pipe line to compressor after re-fixing compressor of existing unit and testing & commissioning to ensure satisfactory performance of unit after gas charging, complete all as directed.
S&F in replacement of copper tubing, confirming to relevant IS, 5/8" and 3/8" flare size, or nearest size, including 3 core 2.5sqmm copper cable including PVC drain pipe and insulation with superlon insulation to copper tubing as required length from indoor to outdoor unit of split AC complete as directed by Engineer in charge.
S&F in replacement of service valve of size 5/8", 1/2" or nearest size suitable for split type AC of any capacity complete all as directed.
S&F in replacement brass flare nut of size 5/8", 1/2" or nearest size suitable for split type AC of any capacity, complete all as directed.
M&L for taking out of old broken drain outlet pipe of any type attached to indoor unit of split type AC and S&F new drain outlet PVC pipe of 20mm dia from indoor unit to nearest suitable drain outlet suitable for split type AC of any capacity complete all as directed by Engineer-in-charge
S & F in replacement factory made angle iron stand suitable for outdoor unit of split type ACs of any capacity complete all as directed.
Labour for shifting of split AC 1.5/ 2 ton capacity one place to another places as required at site and disconnecting of copper tubing, PVC pipe connection and installation of the same on new location indoor / outdoor unit complete with and incluidng gas charging with suitable type of gas, tested on full load on summer season complete all as specified and as directed. Note :- Copper tubing, PVC pipe etc shall be measured and paid saparately under respective items of BOQ.
S&F starting relay with OLP kit suitable for any Make any model refrigerator including with testing and commissioning complete all as specified and as directed.
S&F in replacement of thermostat switch suitable for any model of refrigerator complete all as specified and as directed
S&F electric Lamp 15 watt, 230 volt AC, thread / pin type suitable for any Make & capacity of refrigerator complete all as specified and as directed
S&F in replacement of lamp holder suitable for any Make& capacity / model of refrigerator complete all as specified and as directed
S&F in replacement of door switch push type suitable for any Make & capacity or model of refrigerator complete all as specified and as directed
S&F in replacement of broken / damaged freezer door complete with casing and lock nut as per sample suitable for existing refrigerators of any capacity, complete all as directed.
S&F in replacement of vegetable tray complete suitable for existing model of refrigrators of any capacity, complete all as directed.
S&F door handle suitable for Refrigerators of any Make & model / any capacity, complete all as directed.
S&F PVC bottle guard suitable for 185 to 340 Ltr Refrigerators suitable for any Make & model / any capacity, complete all as directed.
S&F in replacement of chiller tray suitable for existing model of refrigerators of any make & capacity, complete all as directed.
S&F in replacement of metal shelf powder coated suitable for existing model of refrigerator of any make & capacity, complete all as directed.
S&F in replacement of cooling coil suitable for 185/198 Ltrs capacity refrigerator of existing model, complete all as directed by Engr-in-charge.
S&F in replacement of cooling coil suitable for 340 Ltrs capacity refrigerator of existing make / model, complete all as directed by Engr-in-charge.
S&F in replacement of condensor suitable for 185/198 Ltrs capacity refrigerator of existing model, complete all as directed by Engr-in-charge.
S&F in replacement of condensor suitable for 340 Ltrs capacity refrigerator of existing make / model, complete all as directed by Engr-in-charge.
S&F in replacement of PVC gasket magnetic type suitable for any Make & any model / any capacity of refrigerators complete, complete all as directed.
S&F plastic ice cube tray, complete all as directed.
S&F in replacement toughened glass partition / shelves suitable for any capacity or any Make & any model of refrigerator, complete all as directed.
S&F in replacement of timer switch suitable for any Make & any model /any capacity of refrigerator, complete all as directed
M&L for cleaning of water cooler’s tank by from inner side and washed with soda / Acid and de-scaling by brushing and stop leakage (if any) from water tank by soldering / welding and make water tank leak proof and complete all as specified and as directed
M&L for disconnecting the water cooler of any capacity from electric and water connections and cleaning the condenser unit & fins by using carbon tetra chloride cleaning agent, oiling / greasing of fan motor, checking of alignment of motor, cleaning of water storage tank and re-fixing back the same and testing for its smooth functioning complete all as directed by Eng-in-charge.
S&F in replacement 15 mm bore PVC connection 600 mm long with PTMT nut and PVC washer, complete all as specified and directed.
S&F in replacement 15 mm bore PVC connection 900 mm long with PTMT nut and PVC washer, complete all as specified and directed.
S&F in replacement 15 mm bore PVC connection 1200 mm long with PTMT nut and PVC washer, complete all as specified and directed.
S&F in replacement 15mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 142 gms), complete all as specified and directed.
S&F PVC pipe flexible type 32 mm dia suitable for waste water draining complete all as specified and as directed
S&F in replacement over load protector relay (OLP) suitable for water cooler of any capacity complete all as specified and as directed
S&F in replacement self closing push tap, 15mm bore, brass chromium plated, long body, inner threaded complete all as specified and as directed.
S&F in replacement of condenser fan motor, as per existing for water cooler 120/180 Ltrs capacity, single phase, 230 VAC complete all as directed.
S&F in replacement aluminium blade suitable for blower motor of water cooler of 120/180 Ltrs capacity, complete all as specified and as directed
S&F in replacement relay suitable for water cooler of any capacity and make complete all as specified and as directed
S&F in replacement thermostate suitable for water cooler of any type & capacity complete all as specified and as directed
S&F in replacement of blower motor 1/32 HP, 230 volt suitable for 120/180 ltrs capacity water cooler complete with base frame and rubber bush complete all as specified and as directed
S&F in replacement drip tray made of stainless steel suitable for 120/180 ltr capacity water cooler any Make complete all as specified and as directed
S&F water tank gasket suitable for water cooler of 120/180Ltr capacity complete all as specified and as directed
S&F in replacement wiring kit complete suitable for water cooler complete all as specified and as directed
S&F in replacement cooling coil assembly suitable for any Make & model of water cooler including taking down old unserviceable, complete all as directed.
S&F in replacement condenser coil assembly suitable for any Make & any model of water cooler complete including taking down old unserviceable, complete all as directed.
S&F in replacement of corroded bottom portion suitable for water cooler of any make & capacity with MS angle iron of suitable size as per existing, including necessary welding / brazing with mild steel sheet of 1.6mm thick at the base of water cooler for mounting of compressor, blower motor, etc complete all as directed by Engr-in-charge
M&L for servicing of deep freezer unit completely and ensure its smooth functioning and satisfactory performance by means of cleaning each part of the machine carefully, greasing / oiling every moveable part, cleaning the condenser and cooling coil complete with the help of wire brush, soda wash and air pressure through blower, complete all as directed by Engr-in-charge
S & F in replacement of condenser coil suitable for deep freezer of any make and capacity including taking down old unserviceable, complete all as directed.
S & F in replacement of evaporator of deep freezer suitable for any make and capacity including taking down old unserviceable, complete all as directed.
S & F in replacement of de-frost heater of deep freezer suitable for any make and capacity including taking down old unserviceable, complete all as directed.
S & F in replacement of de-frost timer of deep freezer suitable for any make and capacity including taking down old unserviceable, complete all as directed.
S & F in replacement of top spring loaded hinge of deep freezer of any make and capacity including taking down old unserviceable, complete all as directed.
M&L for servicing / repairing of desert cooler's fan by disconnecting from desert cooler with and including cleaning of water water tank by using wire brush and sand papering the surfaces, greasing & oiling of all moveable parts, stop water leakages (If any) from water tank by welding or by using M'seal and make it leak proof and finally applying two coats of synthetic enameled paint on hole body (inner & outer side) of desert cooler, re-assembled the same & fixed it's in original position including replacement of unserviceable spares, complete all as specified and directed by Engr-in-charge. Note:- Spare parts will be measured and paid separately under respective item of BOQ as "Supply only".
Supply only desert cooler fan motor of copper wounded of existing capacities & make complete all as specified and as directed
Supply only fan blade suitable for desert cooler's as per existing size complete all as directed
Supply only capacitor 4 mfd suitable for desert cooler complete all as specified and as directed
S&F in replacement of PVC water distributer junction 3 way / 4 way suitable for desert cooler of any size / capacity complete all as specified and as directed
S&F in replacement of PVC elbow suitable for desert cooler of any size / capacity complete all as specified and as directed
S&F in replacement of PVC flexible pipe, 15 mm dia, suitable for water distribution system to desert cooler of any size / capacity complete all as specified and as directed
S&F in replacement of front grill plastic type suitable for desert cooler with necessary nut, bolts, and washers etc, complete all as specified and as directed.
M&L for replacement of caster wheels (set of four) complete for Air cooler/desert cooler of any size and capacity all as directed by Eng-in-charge.
M&L for removing pump motor set of desert cooler of any size and capacity. S&F new pump motor submersible type single phase AC , 230 Volts , 50 Hz of suitable capacity and size all as directed by Eng-in-charge.
M&L for replacement of switch assembly complete for Air cooler/desert cooler of any size and capacity all as directed by Eng-in-charge.
S&F in replacement of wood wool padding of desert cooler of suitable size including with wire net, weight not less than 450 gms in each panel complete all as specified and as directed
S&F in replacement of sealed compressor unit suitable for refrigerator of capacity 185/198 Ltrs of existing make and capacity, 230 VAC, including taking down of old unserviceable compressor unit complete all as directed by Engineer-in-Charge.
S&F in replacement of sealed compressor unit suitable for refrigerator of capacity 340 Ltrs of existing make and capacity, 230 VAC, including taking down of old unserviceable compressor unit complete all as directed by Engineer-in-Charge.
S&F in replacement of sealed compressor unit suitable for water cooler of capacity 120/180 Ltrs of existing make and capacity, 230 VAC, including taking down of old unserviceable compressor unit complete all as directed by Engineer-in-Charge.
S&F in replacement of sealed compressor unit suitable for deep freezer of capacity 320 Ltrs of existing make and capacity, 230 VAC, including taking down of old unserviceable compressor unit complete all as directed by Engineer-in-Charge.
S&F in replacement of sealed compressor unit suitable for split AC of capacity 1.5 TR of existing make and capacity, 230 VAC, including taking down of old unserviceable compressor unit complete all as directed by Engineer-in-Charge.
S&F in replacement of sealed compressor unit suitable for split AC of capacity 2 TR of existing make and capacity, 230 VAC, including taking down of old unserviceable compressor unit complete all as directed by Engineer-in-Charge.
M&L for gas charging in refrigerator of any capacity & make with R12 / R22 / R410 A/R 134 gas as required quantity including all allied works such as vaccumising the complete system, leak test, pressure test, with and including replacement of copper filters, copper capillary tube, copper tubing of suitable size and required length complete with testing and commissioning, complete all as directed by Engr-in-charge.
M&L for gas charging in water cooler of any capacity & make with R12 / R22 / R410 A/R 134 gas as required quantity including all allied works such as vaccumising the complete system, leak test, pressure test, with and including replacement of copper filters, copper capillary tube, copper tubing of suitable size and required length complete with testing and commissioning, complete all as directed by Engr-in-charge.
M&L for gas charging in deep freezer of any capacity & make with R12 / R22 / R410 A/R 134 gas as required quantity including all allied works such as vaccumising the complete system, leak test, pressure test, with and including replacement of copper filters, copper capillary tube, copper tubing of suitable size and required length complete with testing and commissioning, complete all as directed by Engr-in-charge.
M&L for gas charging in split AC of 1.5 2 TR capacity of any make with R12 / R22 / R410 A/R 134 gas as required quantity including all allied works such as vaccumising the complete system, leak test, pressure test, with and including replacement of copper filters, copper capillary tube, copper tubing of suitable size and required length complete with testing and commissioning, complete all as directed by Engr-in-charge.
M&L for gas charging in mortuary cabinet for 04 body of any make with R12 / R22 / R410 A/R 134 gas as required quantity including all allied works such as vaccumising the complete system, leak test, pressure test, with and including replacement of copper filters, copper capillary tube, copper tubing of suitable size and required length complete with testing and commissioning, complete all as directed by Engr-in-charge.
S&F in replacement of indoor discharge fan suitable for walk-in cooler of 5 TR capacity complete all as directed by Engr-in-charge.
S&F in replacement of indoor discharge fan suitable for walk-in cooler of 1 TR capacity complete all as directed by Engr-in-charge.
S&F in replacement of HP/LP cut off, KP-15 Make - Danfoss/Indfoss suitable for Walk-in-Cooler of any type complete all as directed by Engr-in-charge.
S&F in replacement drier filter of 5/8", 3/8", 1/2" flare size or other nearest flare size, complete all as directed by Engr-in-charge. Make - Sporlon / Catchall or equivalent
S & F in replacement of Digital sub-zero thermostat suitable for the cold storage & programe the thermostat for auto cut-off including all wiring complete all as directed by Engr-in-charge.
Taking out of old unserviceable sealed compressor unit from the Walk in cooler of any make & capacity by means of cutting to suction & discharge pipe line, disconnecting from electric supply, foundation nut bolts, etc and keeping aside as directed and supply and fixing new sealed compressor unit of existing make and capacity, complete all as directed by Engr-in-charge.
M & L for vacuumising the complete system of walk-in cooler with double stage vacuum pump of 2kg/cm2 with and including charging with nitrogen gas up to 250-300 PSI the complete system and check for leak testing and maintaining the pressure for 24 hrs and rectifying the leakage if any in system and after that with and including charging the system with F-22 gas with required quantity, complete all as directed by Engr-in-charge.
S&F in replacement voltage stabilizer 5 KVA, copper winded, complete all as specified and as directed. Make:- APLAB / V Guard / Vintek Electronics (Volina)
S&F in replacement voltage stabilizer 2 KVA, copper winded, complete all as specified and as directed. Make:- APLAB / V Guard / Vintek Electronics (Volina)
S&F in replacement of burnt winding of padestal fans 400 mm sweep, working on 230 volts AC supply, and M&L for re-winding complete with super enamelled copper wire of same guage and weight, replacement of insulation paper, varnishing, heating up and testing complete all as specified and directed by Engr-in-charge
Supply only bearing suitable for Padestal fan 400mm sweep complete all as specified and directed by Engr-in-charge
Supply only brass gun metal bushing suitable for Padestal fan 400mm sweep complete all as specified and directed by Engr-in-charge.
M&L for servicing and cleaning of mortuary Cabinet for capacity of 4 body with suitable chemical detergent and acid using pump, washing the same with water by using pump set and making clear and clean all the tubes, fins and other parts and then clear with suitable dry air blower, Checking and tightening of all electrical connection and making fully serviceable complete all as specified and directed.
Taking out of old unserviceable sealed compressor unit from the motuary Cabinet of any make & capacity by means of cutting to suction & discharge pipe line, disconnecting from electric supply, foundation nut bolts, etc and keeping aside as directed and S&F new sealed compressor unit of existing make and capacity, complete all as directed by Engr-in-Charge.
S & F in replacement of new 5 Amp pin top (ISI marked) of approved make complete all as specified and as directed.
S & F in replacement of new 15 Amp pin top (ISI marked) of approved make complete all as specified and as directed.
S&F in replacement of 3 core, 4 Sqmm, copper conductor PVC insulated flexible cable from main supply point to outdoor/ indoor unit point complete all as specified and directed Engineer-in-Charge
S&F in replacement of 3 core, 2.5 Sqmm, copper conductor PVC insulated flexible cable from main supply point to outdoor/ indoor unit point complete all as specified and directed Engineer-in-Charge
S&F in replacement of 3 core, 1.5 Sqmm, copper conductor PVC insulated flexible cable from main supply point to outdoor/ indoor unit point complete all as specified and directed Engineer-in-Charge
S&F in replacement of 3 core, 6 Sqmm, copper conductor PVC insulated flexible cable from main supply point to outdoor/ indoor unit point complete all as specified and directed Engineer-in-Charge
GRID SYSTEMS (BID ID -3342562)
K.K.Enterprises (BID ID -3342331)
Leo Enterprises (BID ID -3342275)
Sneha Aircool (BID ID -3342977)
Tejas Enterprises (BID ID -3342943)
KSONS (BID ID -3343490)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .