Loading…
Loading…
Tender Value
₹1.2 Cr
EMD Value
₹2.3 L
Closing Date
16 Jul 2026, 2:00 pm
Similar tender results from the same govt authority in the past 3 years.
Telecom work in connection with "Rolling in/out examination with huts with all facilities at 06 stations over Sealdah Division".
SDSTE-TELE-T-02-26-27-CAP
SDSTE-TELE-T-02-26-27-CAP
Open
6 Months
Unknown (Unspecified Location)
₹0
₹2.3 L
19 Jun 2026
19 Jun 2026
2 Jul 2026
BEEN SHOWN IN ITEM BREAKUP SEPARATELY.
NON-SCHEDULE/SOR ITEM vide SL. NO. 1 to 54 GIVEN IN SCHEDULE OF WORK. GST HAS BEEN
SHOWN IN ITEM BREAKUP SEPARATELY.
S No. Item Description of Item Unit Qty Rate Amount
1 1 "Supply, Installation, Testing and Numbers 73.00 10484.30 765353.90
commissioning of Full HD bullet type IP
colour camera along with 128 GB
SD/SDHC/SDXC Memory cardor higher as
edge storage including fixing of CCTV on pole
/ structure with housing canopy, mounting
bracket, waterproof protection arrangement
and all accessories required for outdoor
installation purposes as per RDSO spec No
RDSO/SPN/TC/65/2021, Ver 6.0 amendment
3.0 or latest. Inspection: RDSO "
SEALDAH DIVISION-S AND T/EASTERN RLY
2 2 Supply, Installation, Testing and Numbers 8.00 26375.42 211003.36
commissioning of 16 Channel Network Video
Recorder (NVR) along with all required
accessories required for installation
purposes, technical spec. as per annexure A.
Make: Hikvision/CP-Plus or better. Inspection:
3 3 Supply & installation of 10TB Surveillance Numbers 8.00 28389.83 227118.64
Hard Disk used for Network Video Recorder
(NVR) as per RDSO spec No
RDSO/SPN/TC/65/2021, Ver 6.0 amendment
3.0 or latest. Make: Toshiba/WD/Seagate or
better. Inspection:RDSO
4 4 Supply, Installation, Testing and Numbers 8.00 58913.07 471304.56
Commissioning of 55-inch Full HD Large
Format Display Monitor as per
RDSO/SPN/TC/65/2021 Ver.6.0 Amndt. 3 or
latest Includes Supply & fixing of Standard
OEM Mounting kit along with all the
accessories along with interface cables of
sufficient length for connecting to the PC
Work Station or NMS.Make: LG/Samsung or
better. Inspection:Consignee
5 5 Supply, Installation, Testing and Numbers 8.00 178176.63 1425413.04
commissioning of PC Workstation for
viewing, monitoring and system
management including 24"(Inch) 4K UHD
LED monitor with mouse and keyboard, pre
installed MS oce, antivirus with 3 years
security protection (licensed genuine
software), with 600 VA UPS.This also includes
supply and installation of Graphical User
Interface based Client Software (per
workstation basis) as per RDSO spec. No:
RDSO/SPN/TC/65/2021 Revision 6.0 Amndt. 3
or latest. Inspection:RDSO
6 6 Supply, Installation, Testing and Numbers 32.00 18085.36 578731.52
commissioning of Field Switch with Minimum
8+2 Port Manageable having 8 Nos
10/100/1000 Mbps Base-T POE & 2 Nos 1G
SFP optical Port with loaded SFP module with
all accessories as per RDSO/SPN/TC/65/2021
Version 6.0 with Amendment No. 3 or latest.
Make- Cisco/HP/D-link or better. Inspection:
7 7 "Supply of Gigabit Ethernet Media Converter Pair 50.00 5197.00 259850.00
Single-Mode as per RDSO/ SPN/TC/103/2013
Rev.2 or latest with latest amdt.
Make:Digisol/TP Link or better. Inspection:
Waterproof/Dustproof/Rainproof 8 " (inch)
Heavy Duty Metal Bullet Camera Mounting
Enclosure for Outdoor Purpose with Side
Locking System and Wall Mounting
Bracket/Stand. Inspection: Consignee
concrete base (Mix in ratio 1:1.5:3) , size
approx. 600 x 600 mm, including PCC bed,
shuttering, curing, and finishing with slope
for water drainage. include supply and fixing
of a 1.0-meter long Galvanized Iron (GI) Pole
of diameter 75mm, including necessary base
and top plates, J-bolts with all accessories
required for mounting and alignment of CCTV
camera. Note: All the required material will
be suppiled by the Firm.
SEALDAH DIVISION-S AND T/EASTERN RLY
10 10 "Supply of half size apparatus case (As per Numbers 24.00 6661.02 159864.48
RDSO drawing No. RDSO/S-11507). This
includes supply of location box (GKP type)
with 'E' type lock & key, fitted on location
door on both side, E Type lock (ward No will
be specified by Engineer-in Charge) as per
RDSO Drg. No. SA 3376 and Key to Drg. No.
3377 as per RDSO drawing No. RDSO/S-
11507. Inspection: Consignee "
11 11 "Casting, concreting and curing of concrete Numbers 24.00 2631.36 63152.64
foundation (in ratio 1:3:6), erection and
installation of half apparatus case enclosure
on CC foundation. This includes cost of all
materials required for fixing holding down
bolts, casting, concreting. Note: - bolts, nuts
and washers, bitumen compound to be
supplied by contractor and bitumen
compound to be used in between apparatus
case and foundation as per site engineer.
This also includes bottom of apparatus cases
filled with sand and the outside covered with
masonry work and neat cement plastering. "
12 12 Painting of two coats of synthetic enamel Numbers 24.00 200.00 4800.00
paint over one coat of primer on the
following after scraping & cleaning surface
wherever necessary with contractor's own
supply of paints and primer. Note: The paint
and primer should be from Asian
Paints/Nerolac/Dulux/Berger. The
primer/enamel paints(Aluminiun synthetic,
black enamel, brilliant white and yellow) will
be as per (IS 5660 of 1970)/(IS 2932 of 1974
or latest) of Apparatus case Half size.
(Outside and Inside).
13 13 Fixing of slotted angle and fixing of datacom Numbers 24.00 1271.19 30508.56
equipments inside the location box with all
required fitting arrangements and hylam
sheet and termination/installation of
Switchpower/telecom cables inside the
location box including supply of slotted
angles, hylam sheet wires ferrules for
marking and miscellaneous materials per
location to be supplied by contractor.
14 14 "Supply of Earth electrode mild steel Numbers 24.00 1267.80 30427.20
galvanized, light class, IS:1239(PART-I)-
1979.earth electrode pipe should be with 3
mm thick, 50 mm dia and
perforated(staggered),5 mm dia holes, 2 nos
per 305 mm length. Earth pipe should
include CI threaded cap. Materials to be
procured and designed as per PCSTE/ER's
Drg No. SI/TYP/ 0097 dated 25.03.25 or latest
Inspection: Consignee"
15 15 Supply of MS FLAT (SPEC. NO. 226 STD or Numbers 24.00 772.03 18528.72
latest) of size 35 mm x 6 mm with length 5
mtr with holes of 12 mm dia at both ends as
per PCSTE/ER'S DRG. NO. SI/TYP/0097 dated
25.03.2025 (or latest). Note: (The MS flat
with holes may be supplied in equivalent
length in mtrs or as per site requirement)
Inspection : Consignee.
SEALDAH DIVISION-S AND T/EASTERN RLY
16 16 Fixing of earth electrode including laying and Numbers 24.00 983.90 23613.60
installation of MS flat of size 35 mm x 6 mm
with length 5 mtr or as per extant practice of
Eastern Railway. As per PCSTE/ER'S DRG. NO.
SI/TYP/0097 dated 25.03.2025 or latest. for
apparatus cases, signal post & other
equipment as per instruction of site
engineer. Provision for fixing MS flat at
apparatus cases/ signal post/other
equipment should be made by the firm at
site. Where required necessary holes to be
drilled on the MS Flat . Full threaded bolts of
10 mm dia and length 40 mm should be
welded in the apparatus cases in such way
that the MS flat at apparatus case end can be
fixed from outside or from inside (bolts of 10
mm dia and length 40 mm should be
supplied by the contructor). Welding
arrangement with accessories and welding
materials should be arranged by the
contractor for fixing of bolts at equipment
end where required as per instruction of site
engineer. All hardware and other
miscellaneous materials required for
installation to be supplied by the contractor
except earth electrodes and MS flat. Sig.
Cable as provided by Railway is also to be
laid and terminated on Earth Electrode and
to GI Wire/GI Flat in Location Box.
17 17 Supply of cement concrete enclosure for Numbers 24.00 483.90 11613.60
earth electrodes as per Drg No. S&T/C-
36(NKG) & PCSTE/ER'S DRG. NO. SI/TYP/0097
dated 25.03.2025 or latest. Inspection:
18 18 "Supply of wall mount 9U Rack Enclosures Numbers 8.00 7239.02 57912.16
Networking/Server Rack with power strip 5A
socket 06 no. & MCB, Depth of the Rack:
Upto 500mm,Transparent Toughened Glass
used in front door, CRCA Steel rear door, with
Secure Locks, Support cable entry from top
or bottom, with fan tray and Min. two nos.
fans. Make: Valrack/Dyanamic Rack /D-Link
or better Inspection: Consignee. "
19 19 Installation of 9U/6U/4U rack with necessary Numbers 8.00 469.54 3756.32
angles, fasteners and other fixing
20 20 "Supply of 6 Fibre armoured underground Kilometre 7.00 35294.92 247064.44
Optic fibre cable, conforming to TEC Spec.No.
GR/OFC02/03.SEP.2003 or Latest.
Make:Finolex/POlycab/D-Link or better
Inspection: Consignee"
21 21 Supply of 40 mm dia permanently lubricated Kilometre 7.00 53277.12 372939.84
HDPE telecom: ducts (with chord) as per
RDSO SPEC.NO. RDSO/SPN/TC/45/2013
REVISION 2.0 with latest amendments or
Latest in length of 1000 mtrs/roll For each
km. Of HDPE duct following items are to be
supplied (a) end plugs-2 nos. (b) cable
sealing plugs - 2 nos. (c) plastic couplers slip
fit/push fit type-2 nos. (d) end plugs to be
provided along with drum 2 nos. (Note: The
color of duct will be as per Technical circular
-124A(modified). The colour of the duct is to
be confirmed by the in-charge of the work
before supply) Inspection: Consignee
SEALDAH DIVISION-S AND T/EASTERN RLY
22 22 Laying of HDPE pipe duct, 40/33 mm in Kilometre 7.00 20961.02 146727.14
trenches/overhead and protective works
including pulling of mono-mode armoured
OFC cable through duct in trenches and as
advised by site engineer. Note:- (1) the
contractor will take over the OFC cable from
railway store to site of work duly checked the
continuity of each fibre from end to end . (2)
before & after laying of optical fibre cable
through duct, continuity test from end to end
of each fibre to be made by the contractor to
ensure availability of all duly certified by the
site engineer. Note: OFC & HDPE Duct will be
provided by railway.
23 23 "Supply, installation and Splicing, Numbers 4.00 6497.60 25990.40
termination of 6 fiber OFC with Joining kit
(Splice Closure) as per TEC/GR/TX/OJC-
002/03/APR-2010 or latest and termination
tray with provision of taking out OFC as
required.This includes supply of all
installation accessories including the pigtails
with connector. OFC Jointing kit will be
supplied by the contractor. Inspection:
24 24 Supply of Rack mounting type 06 port Fiber Numbers 32.00 4200.00 134400.00
Distribution Management System (FDMS)
Single Mode, Simplex Fiber Optic Patch
Panels,19 inch 1 U Rack Mountable with
SC/LC connector or as per site requirement
with all accessories including Consumables
Kit Make:/Comscope/Digisol or better
Inspection: Consignee.
25 25 Installation of LIU/FDMS in equipment rack Numbers 32.00 298.53 9552.96
with all accessories as per site condition.
26 26 Splicing /Dropping/Termination of each Fiber CORE 350.00 44.83 15690.50
/Pigtail in the LIU/FDMS/Termination Joints
through fusion Splicing of the termination of
OFC Cables, as per the instructions of
Railway site engineer.
27 27 "Supply of single Mode Armored Optical fiber Numbers 120.00 900.00 108000.00
Patch Cord length 3 meters (LC -SC/SC -
SC/LC-LC/FC-LC) or as per requirenment of
s i t e . Technical Specification: Armoured
(Constructed with a helical stainless steel
spiral over a buffered fiber surrounded by a
layer of aramid and stainless steel mesh with
a heavy duty LSZH outer jacket), 9/125
Micron. Insertion Loss: MAX 0.3 db/Km over
range 1310 nm and 1550 nm Temperature
Range: -10 Degree C to +60 Degree C, RoHS
compliant, Rodent and water proof. Make:
Iveonet/Relemac or better, Inspection :
28 28 "Supply of STP CAT-6 data cable as per Metre 3000.00 38.39 115170.00
EIA/TIA- 568-B.2-1 or latest Make: D-
Link/Digisol or better. Inspection: Consignee."
multi strand (50/0.25 mm dia) cable as per IS
694:1990 reaffirmed 1995 or lates. Make:
Polycab/Finolex/Havells or better Inspection:
30 30 Laying/Blowing of Power Cable/OFC/STP CAT- Metre 4000.00 16.10 64400.00
6/Switch Board Cable/speaker cable/Earth
Cable etc. through PVC Conduit Pipe/ GI
Pipe/HDPE Pipe/PVC trunking etc. as per
direction of the Rly. Representative, This also
includes transportation of cable, PVC Pipe, GI
Pipe,HDPE Pipe etc. to the site. Cable will be
supplied by Railways.
SEALDAH DIVISION-S AND T/EASTERN RLY
31 31 Supply of conduit pipe of size 25mm dia 2 Metre 800.00 24.80 19840.00
mm thickness and 3 mtrs standard length or
as per requirement with ISI mark conforming
to IS:9537 Part-3 or latest Make:
Supreme/Polycab/Jindal/Garware or
Superior.Inspection : Consignee.
32 32 Laying & Fixing of PVC conduit pipe/flexible Metre 900.00 5.27 4743.00
PVC Pipe on wall, bridges, platformshed
complete with 'U' clamps and necessary
fixture screws etc. as per route given by site
engineer of Railways. Note- PVC pipe
supplied by railway.
33 33 Supply of rolled flexible PVC Pipe of 25mm Metre 100.00 24.25 2425.00
dia with ISI mark. Inspection:Consignee
34 34 "Supply of Medium class GI pipes 50 mm dia Metre 1200.00 342.37 410844.00
(3.6 mm thickness) as per IS 1239 (Part 1):
2004 or Latest. Inspection: Consignee "
35 35 "Supply of 'ELBOW'- BENDS to suit GI pipes Numbers 40.00 90.00 3600.00
50 mm dia (3.6 mm thickness) Inspection:
36 36 Laying & Fixing of Medium class GI pipes Metre 1200.00 83.05 99660.00
50/100 mm dia (4.5 mm thickness) &
'ELBOW'- BENDS to suit GI pipes 50 mm dia
(3.6 mm thickness) as per IS 1239 (Part 1):
2004 with socket & coupling on culverts
bridges or at any other locations as decided
by Site Engineer. It includes installation of all
material required for fixing arrangement.
Contractor will install flexible/corrugated
HDPE pipe at the end of GI pipe along with
any masonry work (if required) to protect the
cables from sharp edges and sudden bends.
GI pipe, HDPE & ELBOW'- BENDS will be
provided by railway.
37 37 "Supply of CAT-6 UTP RJ-45 patch cord (5mtr Numbers 200.00 217.28 43456.00
long) twisted stranded cable terminated with
RJ45 modular plugs at both the ends. TIA/EIA-
568-C.2 standard or latest, Insulation
Material : High Density Polyethylene, Outer
Jacket: FR-PVC, Conductor diameter: 23 to 26
AWG, Conductor Metal : Bare Copper, Make
D-Link or better Inspection: Consignee. "
38 38 "Supply of CAT-6 UTP RJ-45 patch cord (3 mtr Numbers 200.00 197.18 39436.00
long) twisted stranded cable terminated with
RJ45 modular plugs at both the ends. TIA/EIA-
568-C.2 standard or latest, Insulation
Material : High Density Polyethylene, Outer
Jacket: FR-PVC, Conductor diameter: 23 to 26
AWG, Conductor Metal : Bare Copper, Make
D-Link or better Inspection: Consignee. "
39 39 Supply of passthrough RJ-45 Connectors Numbers 1000.00 6.66 6660.00
suitable for STP cables, confirming to IS
1293:2019 or latest.Make:-DLink/Digisol or
better Inspection: Consignee.
40 40 Supply of frame, surface box and white cover Numbers 10.00 484.75 4847.50
plates for Two modules. This also includes
supply of RJ-11 Telephone sockets with level
holder Jack type, RJ-45 LAN sockets Jack Type
(Tool less) and blanking plates for one
modules. Make: Legrand or better.
Inspection: Consignee
41 41 Fixing of frame, surface box and white cover Numbers 10.00 121.19 1211.90
plates for Two modules. This also includes
fixing of RJ-11 Telephone sockets with level
holder Jack type, RJ-45 LAN sockets Jack Type
(Tool less) and blanking plates for one
modules. Make: Legrand or better
SEALDAH DIVISION-S AND T/EASTERN RLY
42 42 Supply of HDMI CABLE ( 1.5 METER ) . Make- Numbers 16.00 362.60 5801.60
Honeywell/ZEBRONICS/MX or better.
Inspection:Consignee.
43 43 Supply of HDMI CABLE ( 10 METERS ) Make- Numbers 16.00 1568.00 25088.00
Honeywell/ZEBRONICS/MX or better.
Inspection:Consignee.
44 44 Excavation of cable trench as per cable route cum 1400.00 232.20 325080.00
plan, 1.2 Mtr. deep and of 0.3 Mtr. wide at
bottom as per RDSO sketch No. SDO/CABLE
LAYING/003 or latest alongside the track in
normal (all type) soil/strata, conforming to
distances as per cable route plan and
refilling. This work includes clearing of route
from bushes etc, covering of cable laid in
trench by loose soil for a layer of 50mm
thickness approximately before covering by
bricks(Bricks will be provided by contractor).
The work shall be done as per the extant
practice on Eastern Railway and instructions
of Railway Engineer at site. Note:-(a)for all
trenches from distant signal to home signal
and to relay room, the minimum headway
above the uppermost cable in the trench
should be 600mm. If due to a large no. Of
cables headway is not available, 4" of 1:2:4
concreting should be done.
45 45 Digging of cable trench 0.3 Mtrs. Deep and cum 270.00 421.19 113721.30
0.3 Mtrs. Wide on Platform / Road / Hard
rocky area. Refilling with earth leveling of
trenches & restoring the original surface of
trenches. The sharp edges will be
smoothened out in bottom of the chase and
will be leveled properly. In hard rocky ground
area , cables will be laid normally on layer of
shifted earth of 0.05 mtrs thickness
previously deposited at bottom of the trench
and cables will be covered with layer of sand
or shifted earth of 0.1 mtr thickness. In case
sharp edges of rocky ground cannot be
protected from shifted earth then GI/ CI /PVC
/DWC/ HDPE pipes will be used, if numbers of
cables is small. In case number of cables are
large RCC duct will be used. In isolated
cases, it can be given smooth surface by
using either masonry bricks or cement
concrete. A row of bricks shall then be placed
length wise on the top and jointed with
cement mortar and layer of concrete with
cement plaster shall be provided on top of
the same.Note: This item in hard rocky area
will be operated only where normal depth
i.e.1.2 mtr is not possible and it will be
decided by site engineer/unit officer incharge
46 46 Digging of trench 1.2 Mtrs. deep from rail cum 180.00 235.59 42406.20
flange/ road level and 0.3 Mtrs wide and back
filling after placing of DWC/ RCC/GI pipe.
(Placing of DWC/RCC/GI pipe covered
separately). The ballast disturbed be
screened and dressed as required by
Engineer-in-charge or his representatives and
road tarred immediately. For track crossing,
RDSO sketch No. SDO/CABLE LAYING/009 or
latest and for Road Crossing, RDSO sketch
No. SDO/CABLE LAYING/010 or latest are to
SEALDAH DIVISION-S AND T/EASTERN RLY
47 47 Mechanised drilling/microtunnelling under Metre 500.00 1489.83 744915.00
important/busy metal / concrete road/railway
track with supply & laying of G I pipe and
pulling of cable through GI pipe . This
includes re instatement of the surface to the
original state.As per Site requirement.G.I.
Pipe as per latest IS Spec.
48 48 Cutting the masonry wall at locations Metre 200.00 50.00 10000.00
indicated by Rly.site engineer and repairing
of wall in original state by cement/tiles/white
washing/painting after laying of cable/PVC
etc as per instruction of Rly. site Engineer. All
required materials for this purpose to be
supplied by contractor.
49 49 "Supply and Installation of 1KVA Online UPS Numbers 8.00 25000.00 200000.00
with min. 30 minute backup full load
condition along in with 03 Nos. 12v/26Ah
external battery (Quanta/Exide OR Better)
with terminal, battery rack & accessories set.
Make: Microtek/Numeric/Emerson (Vertiv)/
APC or Better Inspection: Consignee. "
50 50 Supply of Passthrough Crimping tool, Modular Numbers 2.00 734.93 1469.86
Plugs 8P8C RJ-45, 6P6C RJ-12 and 4P4C RJ-11,
7.5 inch steel construction body, All-steel
handles (with padding), Suitable for 22-26
AWG wires, Built-in cable stripper with stop
to ensure correct strip length continuity
tester. Inspection:Consignee
51 51 Supply of Digital Cable network tester (LAN Numbers 4.00 510.40 2041.60
Tester) to Check RJ11, RJ45 and BNC
connectors, Full LED indication lights on both
main and remote unit, to Verify continuity,
opens, shorted or cross wire paired, Indicator
LED Lights, Power 9V Alkaline Battery,
Electricity : 25mA , make: Dlink or better.
Inspection: Consignee
Reflectometer (OTDR), operating at 1550 nm
and 1310 nm for working on single mode
optical fibre as per TEC spec. TEC/GR/TX/OTD
- 001/05/SEP-19 or latest, of reputed make
like Yokogawa/JDSU/Viavi or better.
Consignee shall approve the supply only after
successful demonstration at site. Inspection:
53 53 Supply of Automatic Fusion Splicer for single Numbers 3.00 418313.56 1254940.68
mode Optical fibre cable, along with all
accessories as per TEC spec. TEC/GR/TX/OSM
- 001/04/SEP-12 or latest. Make
Superior/Fujikura or better. Consignee shall
approve the supply only after successful
demonstration at site. Inspection: RITES
54 54 Supply of optical power meter with Visual Numbers 4.00 13994.48 55977.92
Fault Locator, as per TEC spec. GR/OPM-
01/03 Feb 2005 or latest. With SC to LC
Adapter, Charging cable & all required
accessories. Inspection: Consignee. Note-
Item to be supplied after successful
demonstration and Approval of Railway.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender Document
ATTACHMENT
TECHNICALSPECIFICATION.pdf
ATTACHMENT
TechnicalCircularNo124AModified.pdf Technical Circular No 124A Modified
ATTACHMENT
GCCApril2022.pdf
ATTACHMENT
GCCCorrectionSlipNo1to11.pdf
ATTACHMENT
Acceptance of eBG in Works Contract
ATTACHMENT
BID-DOC-SDSTE-TELE-T-02-26-27-CAP.pdf
ATTACHMENT
TechnicalCircularNo124AModified.pdf
ATTACHMENT
Acceptanceofe-BGinWorksContracts.pdf
ATTACHMENT
Download all tender documents and submit your bid